1
|
Stanley CV, Xiao Y, Ling T, Li DS, Chen P. Opto-digital molecular analytics. Chem Soc Rev 2025; 54:3557-3577. [PMID: 40035639 DOI: 10.1039/d5cs00023h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
In contrast to conventional ensemble-average-based methods, opto-digital molecular analytic approaches digitize detection by physically partitioning individual detection events into discrete compartments or directly locating and analyzing the signals from single molecules. The sensitivity can be enhanced by signal amplification reactions, signal enhancement interactions, labelling by strong signal emitters, advanced optics, image processing, and machine learning, while specificity can be improved by designing target-selective probes and profiling molecular dynamics. With the capabilities to attain a limit of detection several orders lower than the conventional methods, reveal intrinsic molecular information, and achieve multiplexed analysis using a small-volume sample, the emerging opto-digital molecular analytics may be revolutionarily instrumental to clinical diagnosis, molecular chemistry and science, drug discovery, and environment monitoring. In this article, we provide a comprehensive review of the recent advances, offer insights into the underlying mechanisms, give comparative discussions on different strategies, and discuss the current challenges and future possibilities.
Collapse
Affiliation(s)
- Chelsea Violita Stanley
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore.
- Lee Kong Chian School of Medicine, Institute for Digital Molecular Analytics and Science, Nanyang Technological University, 636921, Singapore
| | - Yi Xiao
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore.
- Lee Kong Chian School of Medicine, Institute for Digital Molecular Analytics and Science, Nanyang Technological University, 636921, Singapore
| | - Tong Ling
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore.
| | - Dong-Sheng Li
- College of Materials and Chemical Engineering, Key Laboratory of Inorganic Nonmetallic Crystalline and Energy Conversion Materials, China Three Gorges University, Yichang, 443002, P. R. China
| | - Peng Chen
- School of Chemistry, Chemical Engineering and Biotechnology, Nanyang Technological University, 637457, Singapore.
- Lee Kong Chian School of Medicine, Institute for Digital Molecular Analytics and Science, Nanyang Technological University, 636921, Singapore
- Skin Research Institute of Singapore, 308232, Singapore
| |
Collapse
|
2
|
Chen Z, Mao K, Chen Z, Feng R, Du W, Zhang H, Tu C. Isothermal nucleic acid amplification for monitoring hand-foot-and-mouth disease: current status and future implications. Mikrochim Acta 2024; 192:31. [PMID: 39720958 DOI: 10.1007/s00604-024-06899-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2024] [Accepted: 12/13/2024] [Indexed: 12/26/2024]
Abstract
With the global prevalence of the hand-foot-and-mouth disease (HFMD) epidemic, the development of reliable point-of-care testing (POCT) is crucial for the timely identification and prevention of outbreaks. Isothermal nucleic acid amplification techniques (INAATs) have attracted much attention because of their high efficiency for rapid diagnosis. In this work, we systematically summarize the current status of INAATs for HFMD and discuss advantages and drawbacks of various INAATs for HFMD. The INAATs for HFMD detection mainly include loop-mediated isothermal amplification (LAMP), simultaneous amplification and testing (SAT), and recombinase polymerase amplification (RPA). Among them, LAMP has excelled in several diagnostic metrics and has made significant progress in the field of POCT. SAT has been effective in overcoming the problem of RNA degradation. RPA is suited for on-site testing due to its rapid amplification rate and low reaction temperature. In addition, this study explores the potential of INAATs in lateral flow strips (LFS) test and microfluidic devices for HFMD. LFS is typically used for qualitative analysis and supports multiple detection. Microfluidics can integrate necessary processes of sample pre-processing, amplification, and signal output, enabling high-throughput qualitative or quantitative detection and demonstrating the potential of monitoring HFMD. We hope the current work will provide insights into INAATs for monitoring HFMD and serve as a reference for the implementation of on-site EV detection for public health.
Collapse
Affiliation(s)
- Zhen Chen
- School of Public Health, the key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang, 561113, China
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, 550081, China
| | - Kang Mao
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, 550081, China.
| | - Zhuo Chen
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, 550081, China
| | - Rida Feng
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, 550081, China
| | - Wei Du
- Yunnan Provincial Key Laboratory of Soil Carbon Sequestration and Pollution Control, Faculty of Environmental Science & Engineering, Kunming University of Science & Technology, Kunming, 650500, China
| | - Hua Zhang
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, 550081, China
| | - Chenglong Tu
- School of Public Health, the key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang, 561113, China.
- Toxicity Testing Center, Guizhou Medical University, Guian New Region, 561113, China.
| |
Collapse
|
3
|
Tortajada-Genaro LA, Casañ-Raga N, Mas S, Ibañez-Echevarria E, Morais S, Maquieira Á. Reversed-phase allergen microarrays on optical discs for multiplexed diagnostics of food allergies. Mikrochim Acta 2023; 190:166. [PMID: 37010667 PMCID: PMC10070211 DOI: 10.1007/s00604-023-05756-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 03/17/2023] [Indexed: 04/04/2023]
Abstract
A high percentage of the population suffers from multiple food allergies justifying the importance of reliable diagnostic methods. Single-analyte solutions based on the determination of specific immunoglobulins E (sIgE) are safe and fast but are generally time-consuming and expensive. Thus sustainable microanalytical methods that provide multianalyte profiling information are highly demanded. This work presents the in vitro biosensing of specific IgE levels based on a reversed-phase allergen array. The approach consists of optical biosensing supported by direct multiplex immunoassays and on-disc technology. It identifies 12 sIgE associated with food allergies in a single analysis with a low serum sample volume (25 µL). After processing captured images, specific signals for each target biomarker correlate to their concentration. The assay analytically performs well with 0.3 IU/mL and 0.41 IU/mL as the detection and quantification limits in serum, respectively. This novel method achieves excellent clinical specificity (100%) and high sensitivity (91.1%), considering the diagnosis obtained by clinical history and ImmunoCAP analysis. The results demonstrate that microanalytical systems based on allergen arrays can potentially diagnose multiple food allergies and are easily implemented in primary care laboratory settings.
Collapse
Affiliation(s)
- Luis A Tortajada-Genaro
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular Y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera S/N, 46022, Valencia, Spain.
- Departamento de Química, Universitat Politècnica de València, Valencia, Spain.
- Unidad Mixta UPV-La Fe, Nanomedicine and Sensors, IIS La Fe, Valencia, Spain.
| | - Natalia Casañ-Raga
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular Y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera S/N, 46022, Valencia, Spain
| | - Salva Mas
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular Y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera S/N, 46022, Valencia, Spain
| | - Ethel Ibañez-Echevarria
- Hospital Universitari I Politènic La Fe, Servicio de Alergología, Avinguda de Fernando Abril Martorell, 106, 46026, Valencia, Spain
| | - Sergi Morais
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular Y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera S/N, 46022, Valencia, Spain
- Departamento de Química, Universitat Politècnica de València, Valencia, Spain
- Unidad Mixta UPV-La Fe, Nanomedicine and Sensors, IIS La Fe, Valencia, Spain
| | - Ángel Maquieira
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular Y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, Camino de Vera S/N, 46022, Valencia, Spain
- Departamento de Química, Universitat Politècnica de València, Valencia, Spain
- Unidad Mixta UPV-La Fe, Nanomedicine and Sensors, IIS La Fe, Valencia, Spain
| |
Collapse
|
4
|
Tortajada-Genaro LA, Lucío MI, Maquieira Á. Fast DNA biosensing based on isothermal amplification, unmodified gold nanoparticles, and smartphone detection. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.108943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
5
|
Butterworth A, Pratibha P, Marx A, Corrigan DK. Electrochemical Detection of Oxacillin Resistance using Direct-Labeling Solid-Phase Isothermal Amplification. ACS Sens 2021; 6:3773-3780. [PMID: 34595928 DOI: 10.1021/acssensors.1c01688] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Isothermal amplification reactions represent an important and exciting approach to achieve widespread, low cost, and easily implemented molecular diagnostics. This work presents a modified recombinase polymerase amplification (RPA) reaction, which can be directly coupled to a simple electrochemical measurement to ultimately allow development of a nucleic acid-based assay for antibiotic resistance genes. It is shown that use of reagents from a standard RPA reaction kit allows incorporation of horse radish peroxidase-labeled thymine nucleotides into amplified DNA strands, which can be detected via an amperometric signal readout for detection of important gene sequences. The assay is exemplified through detection of fragments of the oxacillin resistance gene in Escherichia coli cells bearing a drug resistance plasmid, achieving a potential limit of detection of 319 cfus/mL and an unoptimized time to result of 60 min. This work serves as a suitable demonstration of the potential for a system to deliver detection of key drug resistance genes at clinically relevant levels.
Collapse
Affiliation(s)
- Adrian Butterworth
- Department of Biomedical Engineering, Wolfson Centre, University of Strathclyde, 106 Rottenrow East, Glasgow G1 1XQ, U.K
| | - Pratibha Pratibha
- Department of Chemistry, Konstanz Research School Chemical Biology, University of Konstanz, Universitätsstraße 10, Konstanz 78457, Germany
| | - Andreas Marx
- Department of Chemistry, Konstanz Research School Chemical Biology, University of Konstanz, Universitätsstraße 10, Konstanz 78457, Germany
| | - Damion K. Corrigan
- Department of Biomedical Engineering, Wolfson Centre, University of Strathclyde, 106 Rottenrow East, Glasgow G1 1XQ, U.K
| |
Collapse
|
6
|
Ichzan AM, Hwang SH, Cho H, Fang CS, Park S, Kim G, Kim J, Nandhakumar P, Yu B, Jon S, Kim KS, Yang H. Solid-phase recombinase polymerase amplification using an extremely low concentration of a solution primer for sensitive electrochemical detection of hepatitis B viral DNA. Biosens Bioelectron 2021; 179:113065. [PMID: 33578116 DOI: 10.1016/j.bios.2021.113065] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 01/30/2021] [Accepted: 01/31/2021] [Indexed: 12/15/2022]
Abstract
Recombinase polymerase amplification (RPA) is considered one of the best amplification methods for realizing a miniaturized diagnostic instrument; however, it is notably challenging to obtain low detection limits in solid-phase RPA. To overcome these difficulties, we combined solid-phase RPA with electrochemical detection and used a new concentration combination of three primers (surface-bound forward primer, solution reverse primer, and an extremely low concentration of solution forward primer). When solid-phase RPA was performed on an indium tin oxide (ITO) electrode modified with a surface-bound forward primer in a solution containing a biotin-terminated solution reverse primer, an extremely low concentration of a solution forward primer, and a template DNA or genomic DNA for a target gene of hepatitis B virus (HBV), amplification occurred mainly in solution until all the solution forward primers were consumed. Subsequently, DNA amplicons produced in solution participated in solid-phase amplification involving surface-bound forward primer and solution reverse primer. Afterward, neutravidin-conjugated DT-diaphorase (DT-D) was attached to a biotin-terminated DNA amplicon on the ITO electrode. Finally, chronocoulometric charges were measured using electrochemical-enzymatic redox cycling involving the ITO electrode, 1,4-naphthoquinone, DT-D, and reduced β-nicotinamide adenine dinucleotide. The detection limit for HBV was measured using microfabricated electrodes and was found to be approximately 0.1 fM. This proposed method demonstrated better amplification efficiency for HBV genomic DNA than solid-phase RPA without using additional solution primer and asymmetric solid-phase RPA.
Collapse
Affiliation(s)
- Andi Muhammad Ichzan
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Sang-Hyun Hwang
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan, College of Medicine, Seoul, 05505, Republic of Korea
| | - Hyejin Cho
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Chiew San Fang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Seonhwa Park
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Gyeongho Kim
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Jihyeon Kim
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Ponnusamy Nandhakumar
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea
| | - Byeongjun Yu
- Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Sangyong Jon
- Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), Daejeon, 34141, Republic of Korea
| | - Kwang-Sun Kim
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea.
| | - Haesik Yang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan, 46241, Republic of Korea.
| |
Collapse
|
7
|
Microfluidic strategies for sample separation and rapid detection of food allergens. Trends Food Sci Technol 2021. [DOI: 10.1016/j.tifs.2021.02.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
8
|
Martorell S, Tortajada-Genaro LA, Maquieira Á. Magnetic concentration of allele-specific products from recombinase polymerase amplification. Anal Chim Acta 2019; 1092:49-56. [DOI: 10.1016/j.aca.2019.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 10/06/2019] [Indexed: 02/07/2023]
|
9
|
Yin J, Suo Y, Zou Z, Sun J, Zhang S, Wang B, Xu Y, Darland D, Zhao JX, Mu Y. Integrated microfluidic systems with sample preparation and nucleic acid amplification. LAB ON A CHIP 2019; 19:2769-2785. [PMID: 31365009 PMCID: PMC8876602 DOI: 10.1039/c9lc00389d] [Citation(s) in RCA: 77] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Rapid, efficient and accurate nucleic acid molecule detection is important in the screening of diseases and pathogens, yet remains a limiting factor at point of care (POC) treatment. Microfluidic systems are characterized by fast, integrated, miniaturized features which provide an effective platform for qualitative and quantitative detection of nucleic acid molecules. The nucleic acid detection process mainly includes sample preparation and target molecule amplification. Given the advancements in theoretical research and technological innovations to date, nucleic acid extraction and amplification integrated with microfluidic systems has advanced rapidly. The primary goal of this review is to outline current approaches used for nucleic acid detection in the context of microfluidic systems. The secondary goal is to identify new approaches that will help shape future trends at the intersection of nucleic acid detection and microfluidics, particularly with regard to increasing disease and pathogen detection for improved diagnosis and treatment.
Collapse
Affiliation(s)
- Juxin Yin
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, 310058, China.
| | - Yuanjie Suo
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, 310058, China.
| | - Zheyu Zou
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, 310058, China.
| | - Jingjing Sun
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, 310058, China.
| | - Shan Zhang
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, 310058, China.
| | - Beng Wang
- Cancer Institute (Key Laboratory of Cancer Prevention and Intervention, National Ministry of Education), The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, 310009 China and Institute of Translational Medicine, Zhejiang University, Hangzhou, 310029 China
| | - Yawei Xu
- College of Biological and Pharmaceutical Engineering, Jilin Agricultural Science and Technology University, Jilin, 132000 China
| | - Diane Darland
- Department of Biology, University of North Dakota, USA.
| | | | - Ying Mu
- Research Centre for Analytical Instrumentation, Institute of Cyber-Systems and Control, State Key Laboratory of Industrial Control Technology, Zhejiang University, Hangzhou, 310058, China.
| |
Collapse
|
10
|
Ivanov AV, Safenkova IV, Zherdev AV, Dzantiev BB. Recombinase polymerase amplification combined with a magnetic nanoparticle-based immunoassay for fluorometric determination of troponin T. Mikrochim Acta 2019; 186:549. [DOI: 10.1007/s00604-019-3686-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/07/2019] [Indexed: 02/07/2023]
|
11
|
Jiang Y, Wu G, Li Y, Wu W. Diameter-definable tubing-microchips for applications in both continuous-flow and TEC-modulated on-chip qPCRs with reaction signal analyzed between different types of Teflon-polymers: PTFE and FEP. RSC Adv 2019; 9:2650-2656. [PMID: 35520483 PMCID: PMC9059869 DOI: 10.1039/c8ra09773a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 12/23/2018] [Indexed: 11/21/2022] Open
Abstract
Recently, the tubing microfluidic system has attracted significant research interest because it waives complicated microfabrication machineries and bonding procedures during the manufacture of microchips; however, due to the limited dimensions in the market, the commercially available micro-tubes are generally fixed in diameters and are unmodifiable in radius; this makes it a challenge to obtain a randomly defined channel-dimension for a tubing microsystem. To solve this problem, herein, we proposed a novel and simple method to obtain a tubing-channel with gradually changed diameter. Both the tensile forces and spectrophotometric properties have been analyzed in this study for systemic characterization; as a proof-of-concept, the inner diameter (ID) of a fluorinated ethylene propylene (FEP) tube has been modified from 0.5 mm to 0.3 mm, and the FEP tube has been further applied to both the thermoelectric (TEC)-modulated on-chip polymerase chain reactions (PCRs) and the continuous flow on-chip PCRs. To the best of our knowledge, this is the first time that an FEP tube with so small ID has been applied to on-chip qPCRs. Based on the comparison with polytetrafluoroethylene (PTFE) regarding the fluorescence signal inside the tube, it can be verified that FEP has much better detection sensitivity than PTFE although these two materials are reckoned to be belonging to the same type of polymer family, generally referred to as Teflon.
Collapse
Affiliation(s)
- Yangyang Jiang
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of SciencesChangchun130033China
| | - Guizhu Wu
- Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University38 Tongyan RdTianjin 300350China
| | - Yuanming Li
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of SciencesChangchun130033China
| | - Wenming Wu
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of SciencesChangchun130033China
| |
Collapse
|
12
|
Sánchez‐Salcedo R, Miranda‐Castro R, de los Santos‐Álvarez N, Lobo‐Castañón MJ. On‐Gold Recombinase Polymerase Primer Elongation for Electrochemical Detection of Bacterial Genome: Mechanism Insights and Influencing Factors. ChemElectroChem 2018. [DOI: 10.1002/celc.201801208] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Raquel Sánchez‐Salcedo
- Departamento de Química Física y AnalíticaUniversidad de Oviedo Julián Clavería 8. 33006 Oviedo Spain
| | - Rebeca Miranda‐Castro
- Departamento de Química Física y AnalíticaUniversidad de Oviedo Julián Clavería 8. 33006 Oviedo Spain
| | | | - María Jesús Lobo‐Castañón
- Departamento de Química Física y AnalíticaUniversidad de Oviedo Julián Clavería 8. 33006 Oviedo Spain
| |
Collapse
|
13
|
Detection of nucleic acids and elimination of carryover contamination by using loop-mediated isothermal amplification and antarctic thermal sensitive uracil-DNA-glycosylase in a lateral flow biosensor: application to the detection of Streptococcus pneumoniae. Mikrochim Acta 2018; 185:212. [DOI: 10.1007/s00604-018-2723-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2017] [Accepted: 02/02/2018] [Indexed: 12/13/2022]
|
14
|
Mayboroda O, Katakis I, O'Sullivan CK. Multiplexed isothermal nucleic acid amplification. Anal Biochem 2018; 545:20-30. [PMID: 29353064 DOI: 10.1016/j.ab.2018.01.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 01/05/2018] [Accepted: 01/09/2018] [Indexed: 12/14/2022]
Abstract
Multiplexed isothermal amplification and detection of nucleic acid sequences and biomarkers is of increasing importance in diverse areas including advanced diagnostics, food quality control and environmental monitoring. Whilst there are several very elegant isothermal amplification approaches, multiplexed amplification remains a challenge, requiring careful experimental design and optimisation, from judicious primer design in order to avoid the formation of primer dimers and non-specific amplification, applied temperature as well as the ratio and concentration of primers. In this review, we describe the various approaches that have been reported to date for multiplexed isothermal amplification, for both "one-pot" multiplexing as well as parallelised multiplexing using loop-mediated isothermal amplification, strand-displacement amplification, helicase-dependent amplification, rolling circle amplification, nucleic acid sequence-based amplification, with a particular focus on recombinase polymerase amplification.
Collapse
Affiliation(s)
- Olena Mayboroda
- Interfibio Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007 Tarragona, Spain
| | - Ioanis Katakis
- Interfibio Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007 Tarragona, Spain.
| | - Ciara K O'Sullivan
- Interfibio Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, Avinguda Països Catalans 26, 43007 Tarragona, Spain; ICREA, Passeig Lluís Companys 23, 08010 Barcelona, Spain.
| |
Collapse
|
15
|
Colorimetric detection of genetically modified organisms based on exonuclease III-assisted target recycling and hemin/G-quadruplex DNAzyme amplification. Mikrochim Acta 2017; 185:75. [PMID: 29594619 DOI: 10.1007/s00604-017-2618-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 12/15/2017] [Indexed: 01/16/2023]
Abstract
An isothermal colorimetric method is described for amplified detection of the CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on (a) target DNA-triggered unlabeled molecular beacon (UMB) termini binding, and (b) exonuclease III (Exo III)-assisted target recycling, and (c) hemin/G-quadruplex (DNAzyme) based signal amplification. The specific binding of target to the G-quadruplex sequence-locked UMB triggers the digestion of Exo III. This, in turn, releases an active G-quadruplex segment and target DNA for successive hybridization and cleavage. The Exo III impellent recycling of targets produces numerous G-quadruplex sequences. These further associate with hemin to form DNAzymes and hence will catalyze H2O2-mediated oxidation of the chromogenic enzyme substrate ABTS2- causing the formation of a green colored product. This finding enables a sensitive colorimetric determination of GMO DNA (at an analytical wavelength of 420 nm) at concentrations as low as 0.23 nM. By taking advantage of isothermal incubation, this method does not require sophisticated equipment or complicated syntheses. Analyses can be performed within 90 min. The method also discriminates single base mismatches. In our perception, it has a wide scope in that it may be applied to the detection of many other GMOs. Graphical abstract An isothermal and sensitive colorimetric method is described for amplified detection of CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on target DNA-triggered molecular beacon (UMB) termini-binding and exonuclease III assisted target recycling, and on hemin/G-quadruplex (DNAzyme) signal amplification.
Collapse
|
16
|
Abstract
Recombinase polymerase amplification (RPA) is a highly sensitive and selective isothermal amplification technique, operating at 37-42°C, with minimal sample preparation and capable of amplifying as low as 1-10 DNA target copies in less than 20 min. It has been used to amplify diverse targets, including RNA, miRNA, ssDNA and dsDNA from a wide variety of organisms and samples. An ever increasing number of publications detailing the use of RPA are appearing and amplification has been carried out in solution phase, solid phase as well as in a bridge amplification format. Furthermore, RPA has been successfully integrated with different detection strategies, from end-point lateral flow strips to real-time fluorescent detection amongst others. This review focuses on the different methodologies and advances related to RPA technology, as well as highlighting some of the advantages and drawbacks of the technique.
Collapse
Affiliation(s)
- Ivan Magriñá Lobato
- INTERFIBIO Consolidated Research Group, Departament d'Enginyeria Química, Universitat Rovira i Virgili, Països Catalans, 26, 43007, Tarragona, Spain
| | - Ciara K O'Sullivan
- INTERFIBIO Consolidated Research Group, Departament d'Enginyeria Química, Universitat Rovira i Virgili, Països Catalans, 26, 43007, Tarragona, Spain.,Institució Catalana de Recerca i Estudis Avançats, Passeig Lluís Companys, 23, 08010 Barcelona, Spain
| |
Collapse
|
17
|
Kober C, Niessner R, Seidel M. Quantification of viable and non-viable Legionella spp. by heterogeneous asymmetric recombinase polymerase amplification (haRPA) on a flow-based chemiluminescence microarray. Biosens Bioelectron 2017; 100:49-55. [PMID: 28863324 DOI: 10.1016/j.bios.2017.08.053] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 08/01/2017] [Accepted: 08/23/2017] [Indexed: 11/19/2022]
Abstract
Increasing numbers of legionellosis outbreaks within the last years have shown that Legionella are a growing challenge for public health. Molecular biological detection methods capable of rapidly identifying viable Legionella are important for the control of engineered water systems. The current gold standard based on culture methods takes up to 10 days to show positive results. For this reason, a flow-based chemiluminescence (CL) DNA microarray was developed that is able to quantify viable and non-viable Legionella spp. as well as Legionella pneumophila in one hour. An isothermal heterogeneous asymmetric recombinase polymerase amplification (haRPA) was carried out on flow-based CL DNA microarrays. Detection limits of 87 genomic units (GU) µL-1 and 26GUµL-1 for Legionella spp. and Legionella pneumophila, respectively, were achieved. In this work, it was shown for the first time that the combination of a propidium monoazide (PMA) treatment with haRPA, the so-called viability haRPA, is able to identify viable Legionella on DNA microarrays. Different proportions of viable and non-viable Legionella, shown with the example of L. pneumophila, ranging in a total concentration between 101 to 105GUµL-1 were analyzed on the microarray analysis platform MCR 3. Recovery values for viable Legionella spp. were found between 81% and 133%. With the combination of these two methods, there is a chance to replace culture-based methods in the future for the monitoring of engineered water systems like condensation recooling plants.
Collapse
Affiliation(s)
- Catharina Kober
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Marchioninistrasse 17, 81377 München, Germany
| | - Reinhard Niessner
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Marchioninistrasse 17, 81377 München, Germany
| | - Michael Seidel
- Institute of Hydrochemistry, Chair of Analytical Chemistry and Water Chemistry, Technical University of Munich, Marchioninistrasse 17, 81377 München, Germany.
| |
Collapse
|
18
|
A portable microreactor with minimal accessories for polymerase chain reaction: application to the determination of foodborne pathogens. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2451-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Tang Y, Cao Y, Yu Y, Yan S, Wang Y, Pan Y, Zhang W. Real-Time Recombinase Polymerase Amplification Assay for the Detection of Vibrio cholerae in Seafood. FOOD ANAL METHOD 2017; 10:2657-2666. [DOI: 10.1007/s12161-017-0820-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
20
|
The G-BHQ synergistic effect: Improved double quenching molecular beacons based on guanine and Black Hole Quencher for sensitive simultaneous detection of two DNAs. Talanta 2017; 174:289-294. [PMID: 28738581 DOI: 10.1016/j.talanta.2017.06.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 05/31/2017] [Accepted: 06/07/2017] [Indexed: 11/21/2022]
Abstract
We designed two double quenching molecular beacons (MBs) with simple structure based on guanine (G base) and Black Hole Quencher (BHQ), and developed a new analytical method for sensitive simultaneous detection of two DNAs by synchronous fluorescence analysis. In this analytical method, carboxyl fluorescein (FAM) and tetramethyl-6-carboxyrhodamine (TAMRA) were respectively selected as fluorophore of two MBs, Black Hole Quencher 1 (BHQ-1) and Black Hole Quencher 2 (BHQ-2) were respectively selected as organic quencher, and three continuous nucleotides with G base were connected to organic quencher (BHQ-1 and BHQ-2). In the presence of target DNAs, the two MBs hybridize with the corresponding target DNAs, the fluorophores are separated from organic quenchers and G bases, leading to recovery of fluorescence of FAM and TAMRA. Under a certain conditions, the fluorescence intensities of FAM and TAMRA all exhibited good linear dependence on their concentration of target DNAs (T1 and T2) in the range from 4 × 10-10 to 4 × 10-8molL-1 (M). The detection limit (3σ, n = 13) of T1 was 3 × 10-10M and that of T2 was 2×10-10M, respectively. Compared with the existing analysis methods for multiplex DNA with MBs, this proposed method based on double quenching MBs is not only low fluorescence background, short analytical time and low detection cost, but also easy synthesis and good stability of MB probes.
Collapse
|
21
|
Yamanaka ES, Tortajada-Genaro LA, Maquieira Á. Low-cost genotyping method based on allele-specific recombinase polymerase amplification and colorimetric microarray detection. Mikrochim Acta 2017. [DOI: 10.1007/s00604-017-2144-0] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
22
|
Microfluidic Devices for Forensic DNA Analysis: A Review. BIOSENSORS-BASEL 2016; 6:bios6030041. [PMID: 27527231 PMCID: PMC5039660 DOI: 10.3390/bios6030041] [Citation(s) in RCA: 80] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 07/07/2016] [Accepted: 07/25/2016] [Indexed: 12/16/2022]
Abstract
Microfluidic devices may offer various advantages for forensic DNA analysis, such as reduced risk of contamination, shorter analysis time and direct application at the crime scene. Microfluidic chip technology has already proven to be functional and effective within medical applications, such as for point-of-care use. In the forensic field, one may expect microfluidic technology to become particularly relevant for the analysis of biological traces containing human DNA. This would require a number of consecutive steps, including sample work up, DNA amplification and detection, as well as secure storage of the sample. This article provides an extensive overview of microfluidic devices for cell lysis, DNA extraction and purification, DNA amplification and detection and analysis techniques for DNA. Topics to be discussed are polymerase chain reaction (PCR) on-chip, digital PCR (dPCR), isothermal amplification on-chip, chip materials, integrated devices and commercially available techniques. A critical overview of the opportunities and challenges of the use of chips is discussed, and developments made in forensic DNA analysis over the past 10–20 years with microfluidic systems are described. Areas in which further research is needed are indicated in a future outlook.
Collapse
|
23
|
Electrochemical detection of Piscirickettsia salmonis genomic DNA from salmon samples using solid-phase recombinase polymerase amplification. Anal Bioanal Chem 2016; 408:8611-8620. [PMID: 27220649 DOI: 10.1007/s00216-016-9639-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2016] [Accepted: 05/13/2016] [Indexed: 10/21/2022]
Abstract
Electrochemical detection of solid-phase isothermal recombinase polymerase amplification (RPA) of Piscirickettsia salmonis in salmon genomic DNA is reported. The electrochemical biosensor was constructed by surface functionalization of gold electrodes with a thiolated forward primer specific to the genomic region of interest. Solid-phase RPA and primer elongation were achieved in the presence of the specific target sequence and biotinylated reverse primers. The formation of the subsequent surface-tethered duplex amplicons was electrochemically monitored via addition of streptavidin-linked HRP upon completion of solid-phase RPA. Successful quantitative amplification and detection were achieved in less than 1 h at 37 °C, calibrating with PCR-amplified genomic DNA standards and achieving a limit of detection of 5 · 10-8 μg ml-1 (3 · 103 copies in 10 μl). The presented system was applied to the analysis of eight real salmon samples, and the method was also compared to qPCR analysis, observing an excellent degree of correlation. Graphical abstract Schematic of use of electrochemical RPA for detection of Psiricketessia salmonis in salmon liver.
Collapse
|