Rugova S, Abboud M. Comparison of One-Drill Protocol to Sequential Drilling In Vitro and In Vivo. Bioengineering (Basel) 2025; 12:51. [PMID: 39851324 PMCID: PMC11762762 DOI: 10.3390/bioengineering12010051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2024] [Revised: 01/05/2025] [Accepted: 01/07/2025] [Indexed: 01/26/2025] Open
Abstract
This study compares the heat generated during bone drilling using different protocols and implant systems, first in vitro and then in vivo with an animal model. In the experimental phase, thermal data were collected using an infrared camera while preparing implant beds in bone similes. The heat generated by a one-drill protocol with a new-generation drill bit and the Straumann BLT sequential drilling protocol was evaluated. The experimental study was then replicated in an animal model to assess the impact of these protocols on early osseointegration, measured by bone-to-implant contact (BIC) at three weeks post-surgery for Straumann BLT SLActive and Medentika Quattrocone implants. The results showed the BLT sequential protocol generated significantly more heat during drilling in bone similes compared to the new-generation drill bit. In the animal model, a histological analysis revealed a trend favoring shorter drilling protocols, with reduced drilling times and a potential advantage for osseointegration, though the BIC differences were not statistically significant. These findings suggest that minimizing the number of drilling steps and thermal stress may enhance osseointegration more effectively than advanced implant surface treatments. This aligns with emerging views on the importance of optimized drilling protocols and designs to reduce heat generation and better preserve surrounding bone structure.
Collapse
Affiliation(s)
- Sihana Rugova
- Department of Oral Biology and Pathology, Stony Brook University, Stony Brook, NY 11794, USA
| | - Marcus Abboud
- School of Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| |
Collapse
|
2
|
Wakamatsu K, Doi K, Kobatake R, Oki Y, Tsuga K. Evaluation of Bone Density for Primary Implant Stability Using a Newly Designed Drill: An In Vitro Study on Polyurethane Bone Blocks. Clin Exp Dent Res 2024; 10:e70048. [PMID: 39610027 PMCID: PMC11604594 DOI: 10.1002/cre2.70048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 10/27/2024] [Accepted: 11/08/2024] [Indexed: 11/30/2024] Open
Abstract
OBJECTIVES Bone density is an important factor for long-term implant success. Peri-implant bone density evaluation before implant placement can be useful for treatment planning, such as the selection of proper implant size or drilling protocol in each case. In this study, we aimed to establish an objective intraoperative bone density evaluation method by measuring the drilling torque value using a newly designed density measurement drill. MATERIALS AND METHODS Drilling torque value measurement was performed intraoperatively using three types of drills; two previously reported drills and a newly designed drill as a density measurement drill. Polyurethane bone blocks of different densities (D1-D4) were used in this experiment. After the measurement, implants were inserted based on the scheduled plan, and insertion torque (IT) and implant stability quotient (ISQ) were measured to assess primary implant stability. RESULTS The drilling torque value increased with the bone blocks' density, and there were significant differences among different densities in all groups (p < 0.05). The drilling torque value showed a positive correlation with IT in all groups (p < 0.05). In addition, the drilling torque value increased with the increase in ISQ in all groups. CONCLUSIONS Within the limitations of this study, a newly designed density measurement drill was able to classify D1-D4 in polyurethane bone blocks despite its narrow diameter, and an objective intraoperative bone evaluation can be achieved. An intraoperative assessment of the drilling torque value can predict primary implant stability and provide valuable information for intraoperative treatment planning, such as undersized drilling protocol and implant size change.
Collapse
Affiliation(s)
- Kaien Wakamatsu
- Department of Advanced ProsthodonticsHiroshima University Graduate School of Biomedical and Health SciencesHiroshimaJapan
| | - Kazuya Doi
- Department of Advanced ProsthodonticsHiroshima University Graduate School of Biomedical and Health SciencesHiroshimaJapan
| | - Reiko Kobatake
- Department of Advanced ProsthodonticsHiroshima University Graduate School of Biomedical and Health SciencesHiroshimaJapan
| | - Yoshifumi Oki
- Department of Advanced ProsthodonticsHiroshima University Graduate School of Biomedical and Health SciencesHiroshimaJapan
| | - Kazuhiro Tsuga
- Department of Advanced ProsthodonticsHiroshima University Graduate School of Biomedical and Health SciencesHiroshimaJapan
| |
Collapse
|
3
|
Liu H, Wu Y, Luo H, Qian F, Li K, Diao X, Xin H. The effect of compressive force in bone tissue induced by implants of different primary stabilities on macrophage polarization and bone regeneration. Colloids Surf B Biointerfaces 2024; 245:114197. [PMID: 39232482 DOI: 10.1016/j.colsurfb.2024.114197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 06/29/2024] [Accepted: 08/29/2024] [Indexed: 09/06/2024]
Abstract
Dental implants with different primary stabilities give rise to distinct stress distributions at the implant-bone interface after placement and exert mechanical force on the cells in the bone tissue. This study aimed to investigate whether the mechanical forces in peri-implant bone participate in the body's immune response and influence macrophage polarization. Therefore, an in vivo rat implantation model with different primary implant stabilities was established. The osteoimmune response and macrophage polarization were investigated, and the osseointegration of the implants was evaluated. In an in vitro experiment, an external compressive force was applied to RAW264.7 cells, and the polarization phenotype was observed. MC3T3-E1 cells were cultured in macrophage-conditioned medium to investigate the regulatory effect of the macrophage-secreted cytokines on the osteogenic differentiation of osteoblasts. In vivo experimental results indicated that the primary stability of implants is positively correlated with the mechanical force. The osteoimmune response was significantly amplified by compressive force generated from implants. This compressive force first induced both M1 and M2 macrophage polarization and then accelerated the progression of the transition to M2 macrophages in the bone repair phase. In vitro, compressive force significantly upregulated the M1 and M2 macrophage polarization. In addition, the suppressive effect of macrophages on the osteogenesis of MC3T3 cells was relieved by cytokines secreted by macrophages under compressive force loading, which promoted their osteogenesis. Overall, these results clarify that compressive force from different primary stabilities is an important influencing factor regulating the osteoimmunne response and macrophage polarization in addition to maintaining the implant.
Collapse
Affiliation(s)
- Huan Liu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Yulu Wu
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Huiwen Luo
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Fei Qian
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Kai Li
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Xiaoou Diao
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
| | - Haitao Xin
- State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, National Clinical Research Center for Oral Diseases, Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology, The Fourth Military Medical University, Xi'an, Shaanxi, China.
| |
Collapse
|
4
|
Romero-Serrano M, Romero-Ruiz MM, Herrero-Climent M, Rios-Carrasco B, Gil-Mur J. Correlation between Implant Surface Roughness and Implant Stability: A Systematic Review. Dent J (Basel) 2024; 12:276. [PMID: 39329842 PMCID: PMC11430827 DOI: 10.3390/dj12090276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Revised: 08/07/2024] [Accepted: 08/20/2024] [Indexed: 09/28/2024] Open
Abstract
The aim of this study was to find in the literature data on the relationship between implant surface roughness and implant stability achieved, from the time of placement to three months afterward, to help us to know what type of surface roughness is more favorable to guarantee implant stability and osseointegration. A systematic review was conducted in accordance with the PRISMA 2020 (Preferred Reporting Items for Systematic Review and Meta-analysis) statement, and the protocol was registered on the Open Science Framework. The specific inclusion and exclusion criteria were selected using the PICOS framework. The databases Medline (PubMed), Scopus, the Web of Science and The Cochrane Library were searched up to October 2023. The selection of studies and data extraction were conducted by two independent reviewers. The review included a total of 11 studies. A total of 1331 dental implant placements were identified. Two of the eleven selected studies were on humans in vivo, eight were on animals in vivo, and one was on animals in vitro. A statistically significant correlation between surface roughness and implant stability as measured by resonance frequency analysis (RFA) was not identified in ten of the eleven selected studies. It appears that there is no correlation between primary stability and the degree of implant roughness. However, there appears to be a correlation between the roughness of the implant and the degree of osseointegration, as indicated by bone-implant contact values. This correlation is more closely related to secondary stability. The great methodological variability makes it difficult to compare data and draw conclusions, so it would be desirable to agree on a common methodology to help draw appropriate conclusions from published studies.
Collapse
Affiliation(s)
- Marta Romero-Serrano
- Department of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain
| | - Manuel-María Romero-Ruiz
- Department of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain
| | - Mariano Herrero-Climent
- Department of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain
- Porto Dental Institute, Periodontology Department, Symmetrya Prothesis, Av. de Montevideu 810, 4150-518 Porto, Portugal
| | - Blanca Rios-Carrasco
- Department of Periodontology, School of Dentistry, Universidad de Seville, C/Avicena S/N, 41009 Seville, Spain
| | - Javier Gil-Mur
- Bioengineering Institute of Technology, Faculty of Medicine and Health Sciences, Universidad International de Cataluña, C/Josep Trueta s/n, Sant Cugat del Vallés, 08195 Barcelona, Spain
| |
Collapse
|
5
|
Canullo L, Menini M, Pesce P, Iacono R, Sculean A, Del Fabbro M. Nano-superhydrophilic and bioactive surface in poor bone environment. Part 1: transition from primary to secondary stability. A controlled clinical trial : Bioactive implant surfaces in poor density bone. Clin Oral Investig 2024; 28:372. [PMID: 38872049 PMCID: PMC11176097 DOI: 10.1007/s00784-024-05747-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 05/27/2024] [Indexed: 06/15/2024]
Abstract
OBJECTIVES Bioactive surfaces were designed to increase the interaction between the surface and the cells. This may speed up the biological stability and loading protocols. MATERIALS AND METHODS 36 patients with D3-D4 bone density were recruited and allocated into two groups. 30 bioactive (test group) and 30 traditional (control group) surfaced implants were placed. Insertion torque value (Ncm), insertion torque curve integral (cumulative torque, Ncm), torque density (Ncm/sec), implant stability quotient (ISQ) measured at three timepoints (baseline (T0), 30 (T30) and 45 (T45) days after surgery), and marginal bone loss (MBL) at 6 months of loading were assessed. RESULTS The mean ISQ and standard deviation at T0, T30, T45 were respectively 74.57 ± 7.85, 74.78 ± 7.31, 74.97 ± 6.34 in test group, and 77.12 ± 5.83, 73.33 ± 6.13, 73.44 ± 7.89 in control group, respectively. Data analysis showed significant differences between groups in ΔISQ at T0-T30 (p = 0.005) and T30-T45 (p = 0.012). Control group showed a significant decrease in ISQ at T30 (p = 0.01) and T45 (p = 0.03) compared to baseline, while no significant change was observed in test group. Due to the stability of the ISQ value ≥ 70, 26 test group and 23 control group implants were functionally loaded after 45 days. Conversely, due to the ISQ < 70 at T45, four test group implants and one control group implant were loaded after 90 days, and 6 control group implants were loaded after 180 days. Neither insertion torque nor ISQ at baseline were correlated with bone density (in Hounsfield units). There was no significant correlation between cumulative torque and ISQ at baseline. There was a significant positive slope in the correlation between torque density and ISQ at baseline, more accentuated in D3 than D4. This correlation remained significant for the test group in D3 bone at day 30 and 45 (p < 0.01 in both time frames), but not in D4 bone, and it was not significant in CG. CONCLUSIONS The bioactive surface showed better behavior in terms of implant stability in D3-D4 bone quality in the early stages of bone healing. Clinical relevance This study demonstrated that the transition from primary to secondary stability is improved using bioactive surface, especially in cases of poor bone environment (D3/D4 bone).
Collapse
Affiliation(s)
- Luigi Canullo
- Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy.
- Department of Periodontology, University of Bern, Bern, Switzerland.
| | - Maria Menini
- Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy
| | - Paolo Pesce
- Department of Surgical Sciences (DISC), University of Genoa, Largo R. Benzi 10, Genoa, 16132, Italy
| | - Roberta Iacono
- Department of Oral and Maxillo-facial Sciences, "Sapienza" University of Rome, Via Caserta 6, Rome, 00161, Italy
| | - Anton Sculean
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| |
Collapse
|
6
|
Orhan ZD, Ciğerim L. A New Approach to Implant Stability Using a Flexible Synthetic Silicate-Additive Beta-Tricalcium Phosphate-Poly(D,L-lactide- co-caprolactone) Bone Graft: An In Vitro Study. Polymers (Basel) 2024; 16:1101. [PMID: 38675020 PMCID: PMC11054415 DOI: 10.3390/polym16081101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/12/2024] [Accepted: 04/15/2024] [Indexed: 04/28/2024] Open
Abstract
The aim of this study was to evaluate the use of a flexible synthetic polymer bone graft to provide implant stability during implant placement in a dense cortical bone model. In the control group (Group 1), sockets were prepared on polyurethane blocks according to the standard implant socket drilling protocol; both oversizing and deepening were applied in Group 2; and only oversizing was applied in Group 3. In Groups 2 and 3, flexible synthetic polymer bone grafts were placed in the sockets prior to implant placement. The implants were placed at the bone level in all groups. The highest torque value obtained was recorded as the insertion torque. In this study, 75 implant sites were included across three groups. The torque values of the implants in the control group were significantly higher than those of the implants with the oversized and deepened sockets and the oversized-only sockets (p < 0.05; p < 0.01). The torque values of the implants with the oversized and deepened sockets were significantly higher than those of the implants with the oversized-only sockets (p < 0.01). In this study, a flexible synthetic polymer bone graft was shown to be effective in achieving implant stability in the management of implants where there has been a loss of primary stability.
Collapse
Affiliation(s)
| | - Levent Ciğerim
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Van Yuzuncu Yil University, 65090 Van, Turkey;
| |
Collapse
|
7
|
Ramesh R, Sasi A, Mohamed SC, Joseph SP. "Compression Necrosis" - A Cause of Concern for Early Implant Failure? Case Report and Review of Literature. Clin Cosmet Investig Dent 2024; 16:43-52. [PMID: 38469322 PMCID: PMC10926919 DOI: 10.2147/ccide.s453798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 02/28/2024] [Indexed: 03/13/2024] Open
Abstract
Purpose Compression necrosis refers to bone tissue damage that can occur when excessive pressure or force is applied to surrounding bone during implant placement. This pressure can compromise blood supply to the bone, leading to necrosis. Compression necrosis is a concern, because it can affect the stability and long-term success of dental implant. Patients and Methods This case report highlights a case of early bone loss and implant failure possibly due to compression necrosis. Clinical data, photographs, radiographs, blood examination report and histology were presented to document the early failure of an implant placed in the mandibular left posterior region of a 33-year-old female patient. Results Radiograph taken six weeks after implant placement showed severe angular defect. Therefore, the implant was surgically removed. Histological examination of the area showed bony trabeculae with an absence of osteoblastic riming, suggestive of necrotic bone. Conclusion Using excessive torque values when placing implants in dense bones can increase the risk of implant failure due to bone over compression. Dental professionals must follow the manufacturer's instructions and employ quality surgical techniques during implant placement into dense cortical bone to minimise risks.
Collapse
Affiliation(s)
- Roshni Ramesh
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| | - Anoop Sasi
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| | - Shahana C Mohamed
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| | - Sonia P Joseph
- Department of Periodontology, Government Dental College, Thiruvananthapuram, Kerala, India
| |
Collapse
|
8
|
Tseng KF, Shiu ST, Hung CY, Chan YH, Chee TJ, Huang PC, Lai PC, Feng SW. Osseointegration Potential Assessment of Bone Graft Materials Loaded with Mesenchymal Stem Cells in Peri-Implant Bone Defects. Int J Mol Sci 2024; 25:862. [PMID: 38255941 PMCID: PMC10815485 DOI: 10.3390/ijms25020862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2023] [Revised: 01/06/2024] [Accepted: 01/07/2024] [Indexed: 01/24/2024] Open
Abstract
Many studies have been exploring the use of bone graft materials (BGMs) and mesenchymal stem cells in bone defect reconstruction. However, the regeneration potential of Algipore (highly purified hydroxyapatite) and Biphasic (hydroxyapatite/beta-tricalcium phosphate) BGMs combined with bone marrow-derived mesenchymal stem cells (BMSCs) remains unclear. Therefore, we evaluated their osseointegration capacities in reconstructing peri-implant bone defects. The cellular characteristics of BMSCs and the material properties of Algipore and Biphasic were assessed in vitro. Four experimental groups-Algipore, Biphasic, Algipore+BMSCs, and Biphasic+BMSCs-were designed in a rabbit tibia peri-implant defect model. Implant stability parameters were measured. After 4 and 8 weeks of healing, all samples were evaluated using micro-CT, histological, and histomorphometric analysis. In the energy-dispersive X-ray spectroscopy experiment, the Ca/P ratio was higher for Algipore (1.67) than for Biphasic (1.44). The ISQ values continuously increased, and the PTV values gradually decreased for all groups during the healing period. Both Algipore and Biphasic BGM promoted new bone regeneration. Higher implant stability and bone volume density were observed when Algipore and Biphasic BGMs were combined with BMSCs. Biphasic BGM exhibited a faster degradation rate than Algipore BGM. Notably, after eight weeks of healing, Algipore with BSMCs showed more bone-implant contact than Biphasic alone (p < 0.05). Both Algipore and Biphasic are efficient in reconstructing peri-implant bone defects. In addition, Algipore BGM incorporation with BSMCs displayed the best performance in enhancing implant stability and osseointegration potential.
Collapse
Affiliation(s)
- Kuo-Fang Tseng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
| | - Shiau-Ting Shiu
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
- Department of Dentistry, Shuang Ho Hospital, Taipei Medical University, New Taipei City 235041, Taiwan
| | - Chia-Yi Hung
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
- School of Dentistry and Graduate Institute of Dental Science, National Defense Medical Center, Taipei City 114201, Taiwan
| | - Ya-Hui Chan
- School of Oral Hygiene, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
| | - Tze-Jian Chee
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
| | - Pai-Chun Huang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
| | - Pin-Chuang Lai
- Department of Periodontics, School of Dentistry, University of Missouri-Kansas City, Kansas City, MO 64108, USA
| | - Sheng-Wei Feng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei City 110301, Taiwan
- School of Dentistry and Graduate Institute of Dental Science, National Defense Medical Center, Taipei City 114201, Taiwan
- Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei City 11031, Taiwan
| |
Collapse
|
9
|
Shu T, Wang X, Li M, Ma S, Cao J, Sun G, Lai T, Liu S, Li A, Qu Z, Pei D. Nanoscaled Titanium Oxide Layer Provokes Quick Osseointegration on 3D-Printed Dental Implants: A Domino Effect Induced by Hydrophilic Surface. ACS NANO 2024; 18:783-797. [PMID: 38117950 DOI: 10.1021/acsnano.3c09285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2023]
Abstract
Three-dimensional printing is a revolutionary strategy to fabricate dental implants. Especially, 3D-printed dental implants modified with nanoscaled titanium oxide layer (H-SLM) have impressively shown quick osseointegration, but the accurate mechanism remains elusive. Herein, we unmask a domino effect that the hydrophilic surface of the H-SLM facilitates blood wetting, enhances the blood shear rate, promotes blood clotting, and changes clot features for quick osseointegration. Combining computational fluid dynamic simulation and biological verification, we find a blood shear rate during blood wetting of the hydrophilic H-SLM 1.2-fold higher than that of the raw 3D-printed implant, which activates blood clot formation. Blood clots formed on the hydrophilic H-SLM demonstrate anti-inflammatory and pro-osteogenesis effects, leading to a 1.5-fold higher bone-to-implant contact and a 1.8-fold higher mechanical anchorage at the early stage of osseointegration. This mechanism deepens current knowledge between osseointegration speed and implant surface characteristics, which is instructive in surface nanoscaled modification of multiple 3D-printed intrabony implants.
Collapse
Affiliation(s)
- Tianyu Shu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Xueliang Wang
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Meng Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Shaoyang Ma
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Jiao Cao
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Guo Sun
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Tao Lai
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Shaobao Liu
- State Key Laboratory of Mechanics and Control for Aerospace Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| | - Zhiguo Qu
- MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, China
| | - Dandan Pei
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an 710049, China
| |
Collapse
|
10
|
Huang YC, Huang YC, Ding SJ. Primary stability of implant placement and loading related to dental implant materials and designs: A literature review. J Dent Sci 2023; 18:1467-1476. [PMID: 37799926 PMCID: PMC10548003 DOI: 10.1016/j.jds.2023.06.010] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 06/12/2023] [Indexed: 10/07/2023] Open
Abstract
A variety of implant placement and loading protocols are identified, ranging from immediate implant placement on the day of extraction to delayed placement for at least 6 months after complete healing. The method of assessment of implant placement and loading plays an important role in the implantation. The expected clinical outcomes depend largely on multiple factors, such as the macroscopic design of the implant, surgical technique, and the quality and quantity of local bone in contact with the implant, which would be described in detail. The purpose of this literature review was to explore the relationship between the factors influencing the implant placement stability and implant design. By understanding the original appearance of implant design and the stability requirements of implant placement, it is hoped that more research in the future can meet the needs of dentists and patients.
Collapse
Affiliation(s)
- Yu-Che Huang
- Institute of Oral Science, Chung Shan Medical University, Taichung, Taiwan
| | - Yen-Chang Huang
- Institute of Oral Science, Chung Shan Medical University, Taichung, Taiwan
| | - Shinn-Jyh Ding
- Institute of Oral Science, Chung Shan Medical University, Taichung, Taiwan
- Department of Stomatology, Chung Shan Medical University Hospital, Taichung, Taiwan
| |
Collapse
|
11
|
Bandela V, Shetty N, Munagapati B, Basany RB, Kanaparthi S. Comparative Evaluation of Osseodensification Versus Conventional Osteotomy Technique on Dental Implant Primary Stability: An Ex Vivo Study. Cureus 2022; 14:e30843. [DOI: 10.7759/cureus.30843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/29/2022] [Indexed: 11/06/2022] Open
|
12
|
Chan YH, Ho KN, Lee YC, Chou MJ, Lew WZ, Huang HM, Lai PC, Feng SW. Melatonin enhances osteogenic differentiation of dental pulp mesenchymal stem cells by regulating MAPK pathways and promotes the efficiency of bone regeneration in calvarial bone defects. Stem Cell Res Ther 2022; 13:73. [PMID: 35183254 PMCID: PMC8858457 DOI: 10.1186/s13287-022-02744-z] [Citation(s) in RCA: 51] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 01/26/2022] [Indexed: 12/20/2022] Open
Abstract
Background Mesenchymal stem cell (MSC)-based tissue engineering plays a major role in regenerative medicine. However, the efficiency of MSC transplantation and survival of engrafted stem cells remain challenging. Melatonin can regulate MSC biology. However, its function in the osteogenic differentiation of dental pulp-derived MSCs (DPSCs) remains unclear. We investigated the effects and mechanisms of melatonin on the osteogenic differentiation and bone regeneration capacities of DPSCs. Methods The biological effects and signaling mechanisms of melatonin with different concentrations on DPSCs were evaluated using a proliferation assay, the quantitative alkaline phosphatase (ALP) activity, Alizarin red staining, a real-time polymerase chain reaction, and a western blot in vitro cell culture model. The in vivo bone regeneration capacities were assessed among empty control, MBCP, MBCP + DPSCs, and MBCP + DPSCs + melatonin preconditioning in four-created calvarial bone defects by using micro-computed tomographic, histological, histomorphometric, and immunohistochemical analyses after 4 and 8 weeks of healing. Results In vitro experiments revealed that melatonin (1, 10, and 100 μM) significantly and concentration-dependently promoted proliferation, surface marker expression (CD 146), ALP activity and extracellular calcium deposition, and osteogenic gene expression of DPSCs (p < 0.05). Melatonin activated the protein expression of ALP, OCN, and RUNX-2 and inhibited COX-2/NF-κB expression. Furthermore, the phosphorylation of mitogen-activated protein kinase (MAPK) p38/ERK signaling was significantly increased in DPSCs treated with 100 μM melatonin, and their inhibitors significantly decreased osteogenic differentiation. In vivo experiments demonstrated that bone defects implanted with MBCP bone-grafting materials and melatonin-preconditioned DPSCs exhibited significantly greater bone volume fraction, trabecular bone structural modeling, new bone formation, and osteogenesis-related protein expression than the other three groups at 4 and 8 weeks postoperatively (p < 0.05). Conclusions These results suggest that melatonin promotes the proliferation and osteogenic differentiation of DPSCs by regulating COX-2/NF-κB and p38/ERK MAPK signaling pathways. Preconditioning DPSCs with melatonin before transplantation can efficiently enhance MSCs function and regenerative capacities.
Collapse
|
13
|
Multidisciplinary Approach for Full-Mouth Rehabilitation of a Young Adult Patient with Ameloblastoma. Case Rep Dent 2021; 2021:8694775. [PMID: 34712499 PMCID: PMC8548147 DOI: 10.1155/2021/8694775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 09/11/2021] [Accepted: 09/29/2021] [Indexed: 11/17/2022] Open
Abstract
Ameloblastoma is a benign but locally invasive neoplasm of the odontogenic epithelium that tends to grow slowly in the mandible or maxilla. It can be highly destructive to the surrounding dental anatomy and can cause death by progressive spread to nearby vital structures in rare cases. Marginal resection is the most effective method of eliminating the tumor, but treatment can further contribute to oral and dental deformity and malfunction. This clinical report describes the dental rehabilitation of a young adult patient diagnosed with ameloblastoma and underwent preliminary marsupialization, segmental mandibulectomy, and fibula free flap reconstruction, followed by mandibular dental implant placements. Orthodontic and rapid palatal expansion for maxillary arch correction was also performed. The treatment goal of regaining dental function and a satisfactory appearance was accomplished.
Collapse
|
14
|
Can the design of the instruments used for undersized osteotomies influence the initial stability of implants installed in low-density bone? An in vitro pilot study. PLoS One 2021; 16:e0257985. [PMID: 34618848 PMCID: PMC8496820 DOI: 10.1371/journal.pone.0257985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Accepted: 09/14/2021] [Indexed: 12/11/2022] Open
Abstract
Objectives The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ). Materials and methods Four groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared. Results Differences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2. Conclusions Undersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.
Collapse
|
15
|
Hao CP, Cao NJ, Zhu YH, Wang W. The osseointegration and stability of dental implants with different surface treatments in animal models: a network meta-analysis. Sci Rep 2021; 11:13849. [PMID: 34226607 PMCID: PMC8257659 DOI: 10.1038/s41598-021-93307-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Accepted: 06/23/2021] [Indexed: 12/12/2022] Open
Abstract
Dental implants are commonly used to repair missing teeth. The implant surface plays a critical role in promoting osseointegration and implant success. However, little information is available about which implant surface treatment technology best promotes osseointegration and implant stability. The aim of this network meta-analysis was to evaluate the osseointegration and stability of four commonly used dental implants (SLA, SLActive, TiUnite, and Osseotite). The protocol of the current meta-analysis is registered in PROSPERO (International Prospective Register of Systematic Reviews) under the code CRD42020190907 ( https://www.crd.york.ac.uk ). We conducted a systematic review following PRISMA and Cochrane Recommendations. Medline (PubMed), Cochrane Library, Embase, and the Web of Science databases were searched. Only randomized controlled trials were considered. Twelve studies were included in the current network meta-analysis, eleven studies were included concerning the osseointegration effect and five studies were included for stability analysis (four studies were used to assess both stability and osseointegration). Rank possibility shows that the SLActive surface best promoted bone formation at an early healing stage and TiUnite seemed to be the best surface for overall osseointegration. For stability, TiUnite seemed to be the best surface. The present network meta-analysis showed that the SLActive surface has the potential to promote osseointegration at an early stage. The TiUnite surface had the best effect on osseointegration regarding the overall healing period. The TiUnite surface also had the best effect in stability.
Collapse
Affiliation(s)
- Chun-Ping Hao
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China
- General Hospital of Northern Theater Command, Shenyang, Liaoning, People's Republic of China
| | - Nan-Jue Cao
- The Fourth Affiliated Hospital, Zhejiang University School of Medicine, Yiwu, Zhejiang, People's Republic of China
| | - Yu-He Zhu
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China
| | - Wei Wang
- Liaoning Provincial Key Laboratory of Oral Diseases, School and Hospital of Stomatology, China Medical University, Shenyang, Liaoning, People's Republic of China.
| |
Collapse
|
16
|
Feng SW, Su YH, Lin YK, Wu YC, Huang YH, Yang FH, Chiang HJ, Yen Y, Wang PDY. Small blood stem cells for enhancing early osseointegration formation on dental implants: a human phase I safety study. Stem Cell Res Ther 2021; 12:380. [PMID: 34215319 PMCID: PMC8254299 DOI: 10.1186/s13287-021-02461-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 06/13/2021] [Indexed: 01/09/2023] Open
Abstract
Background Small blood stem cells (SB cells), isolated from human peripheral blood, demonstrated the ability to benefit bone regeneration and osseointegration. The primary goal of our study is to examine the safety and tolerability of SB cells in dental implantation for human patients with severe bone defects. Methods Nine patients were enrolled and divided into three groups with SB cell treatment doses of 1 × 105, 1 × 106, and 1 × 107 SB cells, and then evaluated by computed tomography (CT) scans to assess bone mineral density (BMD) by Hounsfield units (HU) scoring. Testing was conducted before treatment and on weeks 4, 6, 8, and 12 post dental implantation. Blood and comprehensive chemistry panel testing were also performed. Results No severe adverse effects were observed for up to 6-month trial. Grade 1 leukocytosis, anemia, and elevated liver function were observed, but related with the patient’s condition or the implant treatment itself and not the transplantation of SB cells. The levels of cytokines and chemokines were detected by a multiplex immunological assay. Elevated levels of eotaxin, FGF2, MCP-1, MDC, and IL17a were found among patients who received SB cell treatment. This observation suggested SB cells triggered cytokines and chemokines for local tissue repair. To ensure the efficacy of SB cells in dental implantation, the BMD and maximum stresses via stress analysis model were measured through CT scanning. All patients who suffered from severe bone defect showed improvement from D3 level to D1 or D2 level. The HU score acceleration can be observed by week 2 after guided bone regeneration (GBR) and prior to dental implantation. Conclusions This phase I study shows that treatment of SB cells for dental implantation is well tolerated with no major adverse effects. The use of SB cells for accelerating the osseointegration in high-risk dental implant patients warrants further phase II studies. Trial registration Taiwan Clinical Trial Registry (SB-GBR001) and clinical trial registry of the United States (NCT04451486). Supplementary Information The online version contains supplementary material available at 10.1186/s13287-021-02461-z.
Collapse
Affiliation(s)
- Sheng-Wei Feng
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.,Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, 110, Taiwan
| | - Yi-Han Su
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.,Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, 110, Taiwan
| | - Yen-Kuang Lin
- Research Center of Biostatistics, Taipei Medical University, Taipei, 110, Taiwan
| | - Yu-Chih Wu
- School of Respiratory Therapy, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan.,International PhD Program for Cell Therapy and Regeneration Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan.,Research Center for Cell Therapy and Regeneration Medicine, Taipei Medical University, Taipei, 110, Taiwan
| | - Yen-Hua Huang
- International PhD Program for Cell Therapy and Regeneration Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan.,Research Center for Cell Therapy and Regeneration Medicine, Taipei Medical University, Taipei, 110, Taiwan.,Department of Biochemistry and Molecular Cell Biology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, 110, Taiwan
| | - Fu-Hung Yang
- Research Center of Cancer Translational Medicine, Taipei Medical University, Taipei, 110, Taiwan
| | - Hsi-Jen Chiang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan
| | - Yun Yen
- Research Center of Cancer Translational Medicine, Taipei Medical University, Taipei, 110, Taiwan.
| | - Peter Da-Yen Wang
- School of Dentistry, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan. .,Division of Prosthodontics, Department of Dentistry, Taipei Medical University Hospital, Taipei, 110, Taiwan.
| |
Collapse
|
17
|
Cohen O, Bosshardt DD, Weinberg E, Slutzkey G, Moses O. The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium. MATERIALS 2021; 14:ma14102645. [PMID: 34070127 PMCID: PMC8158354 DOI: 10.3390/ma14102645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 05/13/2021] [Accepted: 05/16/2021] [Indexed: 11/19/2022]
Abstract
Background: Stress concentrated at an implant’s neck may affect bone-to-implant contact (BIC). The objective of this study was to evaluate four different implant neck designs using two different drilling protocols on the BIC. Methods: Ninety-six implants were inserted in 12 minipigs calvarium. Implants neck designs evaluated were: type 1–6 coronal flutes (CFs), 8 shallow microthreads (SMs); type 2–6 CFs,4 deep microthreads (DMs); type 3–4 DMs; type 4–2 CFs, 8 SMs. Two groups of forty-eight implants were inserted with a final drill diameter of 2.8 mm (DP1) or 3.2 mm (DP2). Animals were sacrificed after 1 and 3 months, total-BIC (t-BIC) and coronal-BIC (c-BIC) were evaluated by nondecalcified histomorphometry analysis. Results: At 1 month, t-BIC ranged from 85–91% without significant differences between implant types or drilling protocol. Flutes on the coronal aspect impaired the BIC at 3 m. c-BIC of implant types with 6 CFs was similar and significantly lower than that of implant types 3 and 4. c-BIC of implant type 4 with SMs was highest of all implant types after both healing periods. Conclusions: BIC was not affected by the drilling protocol. CFs significantly impaired the -BIC. Multiple SMs were associated with greater c-BIC.
Collapse
Affiliation(s)
- Omer Cohen
- Department of Periodontology and Dental Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv 6997801, Israel; (E.W.); (G.S.); (O.M.)
- Correspondence: ; Tel.: +972-54-6922393
| | - Dieter D. Bosshardt
- Laboratory of Oral Histology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland;
| | - Evegeny Weinberg
- Department of Periodontology and Dental Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv 6997801, Israel; (E.W.); (G.S.); (O.M.)
| | - Gil Slutzkey
- Department of Periodontology and Dental Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv 6997801, Israel; (E.W.); (G.S.); (O.M.)
| | - Ofer Moses
- Department of Periodontology and Dental Implantology, School of Dental Medicine, Tel-Aviv University, Tel-Aviv 6997801, Israel; (E.W.); (G.S.); (O.M.)
| |
Collapse
|
18
|
Evaluation of the Histomorphometric and Micromorphometric Performance of a Serum Albumin-Coated Bone Allograft Combined with A-PRF for Early and Conventional Healing Protocols after Maxillary Sinus Augmentation: A Randomized Clinical Trial. MATERIALS 2021; 14:ma14071810. [PMID: 33917513 PMCID: PMC8038833 DOI: 10.3390/ma14071810] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 03/29/2021] [Accepted: 04/01/2021] [Indexed: 11/16/2022]
Abstract
The aim of this study was to compare the microarchitecture of augmented bone following maxillary sinus augmentation (MSA) after healing periods of 3 (test) and 6 (control) months using the combination of advanced platelet-rich fibrin (A-PRF) and a serum albumin-coated bone allograft (SACBA). Twenty-six patients with 30 surgical sites who required two-stage MSA were enrolled and grafted with the combination of A-PRF and SACBAs. The surgical sites were randomly allocated to the test or control group. During implant site preparation, 17 bone core biopsy samples were collected from each study group for histological, histomorphometric and micromorphometric analysis. Resonance frequency analysis was performed at the time of implant placement and 6, 8, 10, and 12 weeks postoperatively. The percentage of newly formed bone was 44.89 ± 9.49% in the test group and 39.75 ± 8.15% in the control group (p = 0.100). The results of the µCT analysis showed no significant differences in morphometric parameters between the study groups. The implant stability quotient was not significantly different between the two groups at 10 and 12 weeks postoperatively. Based on these findings, the total treatment time may be reduced by 3 months with the use of A-PRF and SACBAs for two-stage MSA.
Collapse
|
19
|
Staedt H, Kämmerer PW, Goetze E, Thiem DGE, Al-Nawas B, Heimes D. Implant primary stability depending on protocol and insertion mode - an ex vivo study. Int J Implant Dent 2020; 6:49. [PMID: 32880030 PMCID: PMC7468011 DOI: 10.1186/s40729-020-00245-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 07/15/2020] [Indexed: 12/11/2022] Open
Abstract
Background Dental implant primary stability is thought to be a fundamental prerequisite for the long-term survival and success. The aim of this study was to analyze the influence of protocol and insertion mode on dental implant stability ex vivo. One hundred and twenty implants were inserted either manually or machine-driven into porcine mandibles by a standard or over-dimensioned protocol. Dental implant stability was measured via resonance frequency analysis (RFA), insertion torque (IT), and torque out (TO). Results Statistically significant higher IT and TO values were seen after standard protocol insertion (p < 0.05), whereas manual and machine-driven insertion mode showed equivalent values. Conclusions The over-dimensioned protocol exceeded the primary stability values recommended for immediate implant insertion; therefore, it could be recommended as well.
Collapse
Affiliation(s)
- Henning Staedt
- Private Practice and Department of Prosthodontics and Materials Science, University Medical Center Rostock, Strempelstraße 13, 18057, Rostock, Germany
| | - Peer W Kämmerer
- Department of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Elisabeth Goetze
- Department of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Daniel G E Thiem
- Department of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Bilal Al-Nawas
- Department of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Diana Heimes
- Department of Oral- and Maxillofacial Surgery, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
| |
Collapse
|