1
|
Yao J, Ertl-Wagner BB, Dana J, Hanneman K, Kashif Al-Ghita M, Liu L, McInnes MDF, Nicolaou S, Reinhold C, Patlas MN. Canadian radiology: 2024 update. Diagn Interv Imaging 2024; 105:460-465. [PMID: 38942638 DOI: 10.1016/j.diii.2024.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Accepted: 06/11/2024] [Indexed: 06/30/2024]
Abstract
Radiology in Canada is advancing through innovations in clinical practices and research methodologies. Recent developments focus on refining evidence-based practice guidelines, exploring innovative imaging techniques and enhancing diagnostic processes through artificial intelligence. Within the global radiology community, Canadian institutions play an important role by engaging in international collaborations, such as with the American College of Radiology to refine implementation of the Ovarian-Adnexal Reporting and Data System for ultrasound and magnetic resonance imaging. Additionally, researchers have participated in multidisciplinary collaborations to evaluate the performance of artificial intelligence-driven diagnostic tools for chronic liver disease and pediatric brain tumors. Beyond clinical radiology, efforts extend to addressing gender disparities in the field, improving educational practices, and enhancing the environmental sustainability of radiology departments. These advancements highlight Canada's role in the global radiology community, showcasing a commitment to improving patient outcomes and advancing the field through research and innovation. This update underscores the importance of continued collaboration and innovation to address emerging challenges and further enhance the quality and efficacy of radiology practices worldwide.
Collapse
Affiliation(s)
- Jason Yao
- Department of Radiology, McMaster University, Hamilton, ON L8S4K1, Canada.
| | - Birgit B Ertl-Wagner
- Department of Diagnostic Imaging, Division of Neuroradiology, the Hospital for Sick Children, Toronto, ON M5G1X8, Canada; Department of Medical Imaging, Temerty Faculty of Medicine, University of Toronto, Toronto, ON M5S1A8, Canada
| | - Jérémy Dana
- Department of Radiology, McGill University Health Centre, McGill University, Montreal, QC H3G1A4, Canada
| | - Kate Hanneman
- Department of Medical Imaging, Temerty Faculty of Medicine, University of Toronto, Toronto, ON M5S1A8, Canada; University Medical Imaging Toronto, Joint Department of Medical Imaging, University Health Network (UHN), Toronto, ON M5G1X6, Canada
| | | | - Lulu Liu
- Department of Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, BC V5Z1M9, Canada
| | - Matthew D F McInnes
- Faculty of Medicine, University of Ottawa, Ottawa, ON K1H8M5, Canada; Departments of Radiology and Epidemiology, University of Ottawa, Ottawa, ON K1H8L6, Canada; The Ottawa Hospital Research Institute, Clinical Epidemiology Program, Ottawa, ON K1H8L6, Canada
| | - Savvas Nicolaou
- Department of Radiology, Vancouver General Hospital, University of British Columbia, Vancouver, BC V5Z1M9, Canada
| | - Caroline Reinhold
- Department of Radiology, McGill University Health Centre, McGill University, Montreal, QC H3G1A4, Canada
| | - Michael N Patlas
- Department of Medical Imaging, Temerty Faculty of Medicine, University of Toronto, Toronto, ON M5S1A8, Canada; University Medical Imaging Toronto, Joint Department of Medical Imaging, University Health Network (UHN), Toronto, ON M5G1X6, Canada
| |
Collapse
|
2
|
Kaatsch HL, Völlmecke MF, Becker BV, Dillinger D, Kubitscheck L, Wöhler A, Schaaf S, Piechotka J, Schreyer C, Schwab R, Overhoff D, Waldeck S. Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT. Diagnostics (Basel) 2024; 14:2231. [PMID: 39410635 PMCID: PMC11475707 DOI: 10.3390/diagnostics14192231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2024] [Revised: 09/25/2024] [Accepted: 09/28/2024] [Indexed: 10/20/2024] Open
Abstract
Objectives: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. Materials & Methods: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. Results: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (p < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (p < 0.001) except for 50 keV (p > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60-70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. Conclusions: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40-50 keV.
Collapse
Affiliation(s)
- Hanns Leonhard Kaatsch
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, 56072 Koblenz, Germany; (H.L.K.)
| | - Maximilian Franz Völlmecke
- Department of Plastic, Hand and Reconstructive Surgery, Burn Centre, Sarcoma Centre, BG University Hospital Bergmannsheil, 44789 Bochum, Germany
- Department of Trauma Surgery, Hand and Reconstructive Surgery, Bundeswehr Central Hospital, 56072 Koblenz, Germany
| | - Benjamin V. Becker
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, 56072 Koblenz, Germany; (H.L.K.)
- Department of Neuroradiology, University Medical Center Mainz, 55131 Mainz, Germany
| | - Daniel Dillinger
- Department of Vascular Surgery and Endovascular Surgery, Bundeswehr Central Hospital, 56072 Koblenz, Germany
| | - Laura Kubitscheck
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, 56072 Koblenz, Germany; (H.L.K.)
- Bundeswehr Institute of Radiobiology Affiliated to Ulm University, 80937 Munich, Germany
| | - Aliona Wöhler
- Department of General, Visceral and Thoracic Surgery, Bundeswehr Central Hospital, 56072 Koblenz, Germany
| | - Sebastian Schaaf
- Department of General, Visceral and Thoracic Surgery, Bundeswehr Central Hospital, 56072 Koblenz, Germany
| | - Joel Piechotka
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, 56072 Koblenz, Germany; (H.L.K.)
| | - Christof Schreyer
- Department of General, Visceral and Thoracic Surgery, Bundeswehr Central Hospital, 56072 Koblenz, Germany
| | - Robert Schwab
- Department of General, Visceral and Thoracic Surgery, Bundeswehr Central Hospital, 56072 Koblenz, Germany
| | - Daniel Overhoff
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, 56072 Koblenz, Germany; (H.L.K.)
- Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, 68167 Mannheim, Germany
| | - Stephan Waldeck
- Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, 56072 Koblenz, Germany; (H.L.K.)
- Department of Neuroradiology, University Medical Center Mainz, 55131 Mainz, Germany
| |
Collapse
|
3
|
Abu-Omar A, Murray N, Ali IT, Khosa F, Barrett S, Sheikh A, Nicolaou S, O'Neill SB. The Role of Dual-Energy CT in Solid Organ Injury. Can Assoc Radiol J 2024; 75:417-427. [PMID: 38146203 DOI: 10.1177/08465371231215669] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2023] Open
Abstract
The liver, spleen, and kidneys are the commonest injured solid organs in blunt and penetrating trauma. The American Association for the Surgery of Trauma (AAST) Organ Injury Scale (OIS) is the most widely accepted system for categorizing traumatic injuries. Grading systems allow clear communication of findings between clinical teams and assign a measurable severity of injury, which directly correlates with morbidity and mortality. The 2018 revised AAST OIS emphasizes reliance on CT for accurate grading; in particular regarding vascular injuries. Dual-Energy CT (DECT) has emerged as a promising tool with multiple clinical applications already demonstrated. In this review article, we summarize the basic principles of CT attenuation to refresh the minds of our readers and we scrutinize DECT's technology as opposed to conventional Single-Energy CT (SECT). This is followed by outlining the benefits of various DECT postprocessing techniques, which authors of this article refer to as the 3Ms (Mapping of Iodine, Material decomposition, and Monoenergetic virtual imaging), in aiding radiologists to confidently assign an OIS as well as problem solve complex injury patterns. In addition, a thorough discussion of changes to the revised AAST OIS focusing on definitions of key terms used in reporting injuries is described.
Collapse
Affiliation(s)
- Ahmad Abu-Omar
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Nicolas Murray
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Ismail T Ali
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Faisal Khosa
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Sarah Barrett
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Adnan Sheikh
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Savvas Nicolaou
- Department of Emergency Radiology, University of British Columbia, Vancouver General Hospital, Vancouver, BC, Canada
| | - Siobhán B O'Neill
- Department of Radiology, University of Alberta, University of Alberta Hospital, Edmonton, AB, Canada
| |
Collapse
|
4
|
Nehra AK, Dane B, Yeh BM, Fletcher JG, Leng S, Mileto A. Dual-Energy, Spectral and Photon Counting Computed Tomography for Evaluation of the Gastrointestinal Tract. Radiol Clin North Am 2023; 61:1031-1049. [PMID: 37758355 DOI: 10.1016/j.rcl.2023.06.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
The use of dual-energy computed tomography (CT) allows for reconstruction of energy- and material-specific image series. The combination of low-energy monochromatic images, iodine maps, and virtual unenhanced images can improve lesion detection and disease characterization in the gastrointestinal tract in comparison with single-energy CT.
Collapse
Affiliation(s)
- Avinash K Nehra
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA.
| | - Bari Dane
- Department of Radiology, New York University Langone Medical Center, 550 First Avenue, New York, NY 10016, USA
| | - Benjamin M Yeh
- Department of Radiology and Biomedical Imaging, University of California, 505 Parnassus Avenue, San Francisco, CA 94143, USA
| | - Joel G Fletcher
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Shuai Leng
- Department of Radiology, Mayo Clinic, 200 First Street Southwest, Rochester, MN 55905, USA
| | - Achille Mileto
- Department of Radiology, Virginia Mason Medical Center, 1100 9th Avenue, Seattle, WA 98101, USA
| |
Collapse
|
5
|
Wang S, Zhang Y, Xu Y, Yang P, Liu C, Gong H, Lei J. Progress in the application of dual-energy CT in pancreatic diseases. Eur J Radiol 2023; 168:111090. [PMID: 37742372 DOI: 10.1016/j.ejrad.2023.111090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 08/19/2023] [Accepted: 09/06/2023] [Indexed: 09/26/2023]
Abstract
Pancreatic diseases are difficult to diagnose due to their insidious onset and complex pathophysiological developmental characteristics. In recent years, dual-energy computed tomography (DECT) imaging technology has rapidly advanced. DECT can quantitatively extract and analyze medical imaging features and establish a correlation between these features and clinical results. This feature enables the adoption of more modern and accurate clinical diagnosis and treatment strategies for patients with pancreatic diseases so as to achieve the goal of non-invasive, low-cost, and personalized treatment. The purpose of this review is to elaborate on the application of DECT for the diagnosis, biological characterization, and prediction of the survival of patients with pancreatic diseases (including pancreatitis, pancreatic cancer, pancreatic cystic tumor, pancreatic neuroendocrine tumor, and pancreatic injury) and to summarize its current limitations and future research prospects.
Collapse
Affiliation(s)
- Sha Wang
- The First Clinical Medical College of Lanzhou University, Lanzhou 730000, China
| | - Yanli Zhang
- The First Clinical Medical College of Lanzhou University, Lanzhou 730000, China; Department of Radiology, The First Hospital of Lanzhou University, Lanzhou 730000, China; Radiological Clinical Medicine Research Center of Gansu Province, Lanzhou 730000, China
| | - Yongsheng Xu
- The First Clinical Medical College of Lanzhou University, Lanzhou 730000, China; Department of Radiology, The First Hospital of Lanzhou University, Lanzhou 730000, China; Radiological Clinical Medicine Research Center of Gansu Province, Lanzhou 730000, China
| | - Pengcheng Yang
- Department of Radiology, The First Hospital of Lanzhou University, Lanzhou 730000, China
| | - Chuncui Liu
- The First Clinical Medical College of Lanzhou University, Lanzhou 730000, China
| | - Hengxin Gong
- The First Clinical Medical College of Lanzhou University, Lanzhou 730000, China
| | - Junqiang Lei
- The First Clinical Medical College of Lanzhou University, Lanzhou 730000, China; Department of Radiology, The First Hospital of Lanzhou University, Lanzhou 730000, China; Radiological Clinical Medicine Research Center of Gansu Province, Lanzhou 730000, China.
| |
Collapse
|
6
|
Shim J, Kim K, Lee Y. Effect of iodine concentration reduction by comparison of virtual monoenergetic image quality with dual-energy computed tomography. Appl Radiat Isot 2023; 200:110967. [PMID: 37527620 DOI: 10.1016/j.apradiso.2023.110967] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 07/20/2023] [Accepted: 07/28/2023] [Indexed: 08/03/2023]
Abstract
This study aimed to evaluate the image quality of virtual monoenergetic images (VMIs) with tube voltage modulation in pediatric abdominal computed tomography (CT) examination and to determine the effect of decreasing contrast agent concentration. Using a 1-year old pediatric phantom, five contrast agent concentration diluent tubes of 100%, 80%, 60%, 40%, and 20% of the same concentration as the average Hounsfield unit (HU) in the descending aorta were inserted, and the mixed image and VMIs (40, 60, and 80 keV) acquired using dual-energy CT were compared with single-energy CT (SECT) images. For quantitative evaluation, the HU and coefficient of variation (COV) of each image were compared and analyzed. The analysis revealed that the HU of the 40 keV VMIs, acquired with a tube voltage of 70 kV and 100% contrast agent concentration, was 61% higher than that of the SECT image. The results showed that SECT had the lowest COV among all contrast agent concentration and tube voltage combinations, while the 40 keV image acquired at 70 kV had the second-lowest COV value. The HU of the 40 keV image acquired at 70 kV at a contrast agent concentration of 100% was 9% higher than that of SECT at 80% concentration. This study confirms that 40 keV VMIs are more useful than SECT images for vascular diagnosis with contrast in pediatric abdominal CT examinations and that a 20% reduction in contrast agent concentration can reduce the risk of contrast agent concentration-induced nephrotoxicity in pediatric patients by increasing the subjective acceptability of image quality for diagnosis.
Collapse
Affiliation(s)
- Jina Shim
- Department of Diagnostic Radiology, Severance Hospital, Seoul, Republic of Korea
| | - Kyuseok Kim
- Department of Radiological Science, Gachon University, Incheon, Republic of Korea.
| | - Youngjin Lee
- Department of Radiological Science, Gachon University, Incheon, Republic of Korea.
| |
Collapse
|
7
|
Cheng F, Liu Y, Du L, Wang L, Li L, Shi J, Wang X, Zhang J. Evaluation of optimal monoenergetic images acquired by dual-energy CT in the diagnosis of T staging of thoracic esophageal cancer. Insights Imaging 2023; 14:33. [PMID: 36763193 PMCID: PMC9918671 DOI: 10.1186/s13244-023-01381-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Accepted: 01/29/2023] [Indexed: 02/11/2023] Open
Abstract
OBJECTIVES The purpose of our study was to objectively and subjectively assess optimal monoenergetic image (MEI (+)) characteristics from dual-energy CT (DECT) and the diagnostic performance for the T staging in patients with thoracic esophageal cancer (EC). METHODS In this retrospective study, patients with histopathologically confirmed EC who underwent DECT from September 2019 to December 2020 were enrolled. One standard polyenergetic image (PEI) and five MEI (+) were reconstructed. Two readers independently assessed the lesion conspicuity subjectively and calculated the contrast-to-noise ratio (CNR) and the signal-to-noise ratio (SNR) of EC. Two readers independently assessed the T stage on the optimal MEI (+) and PEI subjectively. Multiple quantitative parameters were measured to assess the diagnostic performance to identify T1-2 from T3-4 in EC patients. RESULTS The study included 68 patients. Subjectively, primary tumor delineation received the highest ratings in MEI (+) 40 keV of the venous phase. Objectively, MEI (+) images showed significantly higher SNR compared with PEI (p < 0.05), peaking at MEI (+) 40 keV in the venous phase. CNR of tumor (MEI (+) 40 keV -80 keV) was all significantly higher than PEI in arterial and venous phases (p < 0.05), peaking at MEI (+) 40 keV in venous phases. The agreement between MEI (+) 40 keV and pathologic T categories was 81.63% (40/49). Rho values in venous phases had excellent diagnostic efficiency for identifying T1-2 from T3-4 (AUC = 0.84). CONCLUSIONS MEI (+) reconstructions at low keV in the venous phase improved the assessment of lesion conspicuity and also have great potential for preoperative assessment of T staging in patients with EC.
Collapse
Affiliation(s)
- Fanrong Cheng
- grid.190737.b0000 0001 0154 0904Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030 China ,People’s Hospital of Rongchang District, Chongqing, 402460 China
| | - Yan Liu
- grid.190737.b0000 0001 0154 0904Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030 China
| | - Lihong Du
- grid.190737.b0000 0001 0154 0904Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030 China
| | - Lei Wang
- grid.190737.b0000 0001 0154 0904Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030 China
| | - Lan Li
- grid.190737.b0000 0001 0154 0904Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030 China
| | - Jinfang Shi
- grid.190737.b0000 0001 0154 0904Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030 China
| | - Xiaoxia Wang
- Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030, China.
| | - Jiuquan Zhang
- Department of Radiology, Chongqing Key Laboratory for Intelligent Oncology in Breast Cancer (iCQBC), Chongqing University Cancer Hospital, Chongqing, 400030, China.
| |
Collapse
|
8
|
Mahmoudi S, Lange M, Lenga L, Yel I, Koch V, Booz C, Martin S, Bernatz S, Vogl T, Albrecht M, Scholtz JE. Salvaging low contrast abdominal CT studies using noise-optimised virtual monoenergetic image reconstruction. BJR Open 2022; 4:20220006. [PMID: 36105416 PMCID: PMC9446156 DOI: 10.1259/bjro.20220006] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 04/21/2022] [Accepted: 04/22/2022] [Indexed: 11/25/2022] Open
Abstract
Objectives To assess the impact of noise-optimised virtual monoenergetic imaging (VMI+) on image quality and diagnostic evaluation in abdominal dual-energy CT scans with impaired portal-venous contrast. Methods We screened 11,746 patients who underwent portal-venous abdominal dual-energy CT for cancer staging between 08/2014 and 11/2019 and identified those with poor portal-venous contrast.Standard linearly-blended image series and VMI+ image series at 40, 50, and 60 keV were reconstructed. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal organs and vascular structures were calculated. Image noise, image contrast and overall image quality were rated by three radiologists using 5-point Likert scale. Results 452 of 11,746 (4%) exams were poorly opacified. We excluded 190 cases due to incomplete datasets or multiple exams of the same patient with a final study group of 262. Highest CNR values in all abdominal organs (liver, 6.4 ± 3.0; kidney, 17.4 ± 7.5; spleen, 8.0 ± 3.5) and vascular structures (aorta, 16.0 ± 7.3; intrahepatic vein, 11.3 ± 4.7; portal vein, 15.5 ± 6.7) were measured at 40 keV VMI+ with significantly superior values compared to all other series. In subjective analysis, highest image contrast was seen at 40 keV VMI+ (4.8 ± 0.4), whereas overall image quality peaked at 50 keV VMI+ (4.2 ± 0.5) with significantly superior results compared to all other series (p < 0.001). Conclusions Image reconstruction using VMI+ algorithm at 50 keV significantly improves image contrast and image quality of originally poorly opacified abdominal CT scans and reduces the number of non-diagnostic scans. Advances in knowledge We validated the impact of VMI+ reconstructions in poorly attenuated DECT studies of the abdomen in a big data cohort.
Collapse
Affiliation(s)
- Scherwin Mahmoudi
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Marvin Lange
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Lukas Lenga
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Vitali Koch
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Simon Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Simon Bernatz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Thomas Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Moritz Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai, Frankfurt, Germany
| |
Collapse
|
9
|
Mroueh N, Cao J, Kambadakone A. Dual-Energy CT in the Pancreas. JOURNAL OF GASTROINTESTINAL AND ABDOMINAL RADIOLOGY 2022. [DOI: 10.1055/s-0042-1744494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
AbstractDual-energy computed tomography (DECT) is an evolving imaging technology that is gaining popularity, particularly in different abdominopelvic applications. Essentially, DECT uses two energy spectra simultaneously to acquire CT attenuation data which is used to distinguish among structures with different tissue composition. The wide variety of reconstructed image data sets makes DECT especially attractive in pancreatic imaging. This article reviews the current literature on DECT as it applies to imaging the pancreas, focusing on pancreatitis, trauma, pancreatic ductal adenocarcinoma, and other solid and cystic neoplasms. The advantages of DECT over conventional CT are highlighted, including improved lesion detection, radiation dose reduction, and enhanced image contrast. Additionally, data exploring the ideal protocol for pancreatic imaging using DECT is reviewed. Finally, limitations of DECT in pancreatic imaging as well as recommendations for future research are provided.
Collapse
Affiliation(s)
- Nayla Mroueh
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States
| | - Jinjin Cao
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States
| | - Avinash Kambadakone
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, United States
| |
Collapse
|
10
|
Higashigaito K, Euler A, Eberhard M, Flohr TG, Schmidt B, Alkadhi H. Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT. Acad Radiol 2022; 29:689-697. [PMID: 34389259 DOI: 10.1016/j.acra.2021.06.018] [Citation(s) in RCA: 70] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 06/28/2021] [Accepted: 06/30/2021] [Indexed: 02/07/2023]
Abstract
RATIONALE AND OBJECTIVES To determine quantitative and qualitative image quality of contrast-enhanced abdominal photon-counting detector CT (PCD-CT) compared to energy-integrating detector CT (EID-CT) in the same patients. MATERIAL AND METHODS Thirty-nine patients (mean age 63 ± 10 years, 10 females, mean BMI 26.0 ± 5.7 kg/m2) were retrospectively included who underwent clinically indicated, contrast-enhanced abdominal CT in portal-venous phase with first-generation dual-source PCD-CT and who underwent previous abdominal CT with EID-CT. For both scan, same contrast media protocol was used. PCD-CT was performed in QuantumPlus mode (obtaining full spectral information) at 120kVp. EID-CT was performed using automated tube voltage selection (reference tube voltage 100kVp). In PCD-CT, virtual monoenergetic images (VMI) were reconstructed in 10keV intervals (40-90 keV). Tube current-time product in PCD-CT was modified in each patient to obtain same volume CT-dose-index (CTDIvol) as with EID-CT. Attenuation of organs and vascular structures were measured, noise quantified, and contrast-to-noise ratio (CNR) calculated. Two independent, blinded radiologists assessed subjective image quality using a 5-point Likert scale (overall image quality, image noise, contrast, and liver lesion conspicuity). RESULTS Median time interval between the scan was 12 months. BMI (p = 0.905) and CTDIvol (p = 0.984) were similar between scans. CNRparenchymal and CNRvascular of VMI from PCD-CT at 40 and 50keV were significantly higher than EID-CT (all, p < 0.05). Overall, inter-reader agreement for all subjective image quality readings was substantial (Krippendorff's alpha = 0.773). Overall image quality of VMI was rated similar at 50 and 60 keV compared to EID-CT (all, p > 0.05). Subjective image noise was significantly higher at 40-50 keV, contrast significantly higher at 40-60 keV (all, p < 0.05). Lesion conspicuity was rated similar on all images. CONCLUSION Our intra-individual analysis of abdominal PCD-CT indicates that VMI at 50 keV shows significantly higher CNR at similar subjective image quality as compared to EID-CT at identical radiation dose.
Collapse
|
11
|
Zeng Y, Geng D, Zhang J. Noise-optimized virtual monoenergetic imaging technology of the third-generation dual-source computed tomography and its clinical applications. Quant Imaging Med Surg 2021; 11:4627-4643. [PMID: 34737929 DOI: 10.21037/qims-20-1196] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2020] [Accepted: 06/02/2021] [Indexed: 02/05/2023]
Abstract
The third-generation dual-source computed tomography (DSCT) is among the most advanced imaging methods. It employs noise-optimized virtual monoenergetic imaging (VMI+) technology. It uses the frequency-split method to extract high-contrast image information from low-energy images and low-noise information from images reconstructed at an optimal energy level, combining them to obtain the final image with improved quality. This review is the first to summarize the results of clinical studies that primarily and recently evaluated the VMI+ technique based on tumor, blood vessel, and other lesion classification. We aim to assist radiologists in quickly selecting the appropriate energy level when performing image reconstruction for superior image quality in clinical work and providing several ideas for future scientific research of the VMI+ technique. Presently, VMI+ reconstruction is mostly used for images of various tumors or blood vessels, including coronary plaques, coronary stents, deep vein thromboses, pulmonary embolisms (PEs), active arterial hemorrhages, and endoleaks after endovascular aneurysm repair. In addition, VMI+ has been used for imaging children's heads, liver lesions, pancreatic lacerations, and reducing metal artifacts. Regarding the reconstruction at the optimal energy level, the VMI+ technique yielded a higher image quality than the pre-optimized virtual monoenergetic imaging (VMI) technique and single-energy CT. Moreover, either low concentrations of contrast medium or low iodine injection rates can be applied before VMI+ reconstruction at a low-energy level to reduce contrast agent-related kidney injury risk. After reconstructing an image at the optimal energy level, both the image's window width and level can also be adjusted to improve the image effect's reach and diagnosis suitability. To improve image quality and lesion-imaging clarity and reduce the use of contrast agents, VMI+ reconstruction technology has been applied clinically, in which the selection of energy level is the key to the whole reconstruction process. Our review summarizes these optimal levels for radiologists' reference and suggests new ideas for the direction of future VMI+ research.
Collapse
Affiliation(s)
- Yanwei Zeng
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| | - Daoying Geng
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| | - Jun Zhang
- Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.,Institute of Functional and Molecular Medical Imaging, Fudan University, Shanghai, China.,Center for Shanghai Intelligent Imaging for Critical Brain Diseases Engineering and Technology Research, Shanghai, China
| |
Collapse
|