Derycke L, Avril S, Drouhard V, Albertini JN, Millon A. Computational prediction of Gore Excluder conformable endoprosthesis in the infrarenal aortic neck: results of the ACSSim study. Comput Biol Med 2025; 192:110228. [PMID: 40367626 DOI: 10.1016/j.compbiomed.2025.110228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Revised: 03/12/2025] [Accepted: 04/16/2025] [Indexed: 05/16/2025]
Abstract
BACKGROUND AND OBJECTIVE The Gore® Excluder® Conformable (EXCC) device offers a less invasive and less risky alternative to open surgery and complex endovascular repair of abdominal aortic aneurysms for patients with hostile aortic neck anatomies. Indeed, its specific structure has sufficient conformability to prevent proximal sealing complications. Nevertheless, its mechanical behavior is more complex than the one of standard devices, and in complex anatomies, its deployment in the proximal neck of the aortic aneurysm remains difficult to predict. The aim of the present study was to develop and validate a digital twin of EXCC deployment that could accurately predict proximal endoprosthesis sealing. METHODS Twenty patients who underwent endovascular aortic aneurysm repair with the EXCC device for complex anatomies in one aortic center were selected. Endoprosthesis deployment in each aorta was simulated by the finite element (FE) method. We compared the positions predicted by the FE simulations with post-operative computed tomography angiography (CTA), focusing on the proximal axis angle, the stent center positions and stent-rings diameters through a principal component analysis. RESULTS A successful FE simulation of endoprosthesis deployment could be performed for each of the twenty patients. Relative diameter and vector mean deviations were 4.65 ± 3.85 % and 3.00 ± 1.41 mm, respectively. Axis angle mean deviation was 10.64 ± 5.09°. Outputs show satisfying agreement between numerical simulations and post-operative CTA. Mean proximal apposition was 81.64 ± 11.35 %. Minimal and maximal endoprosthesis appositions were 54.27 % and 95.11 %, respectively. CONCLUSIONS The FE model predicted accurately stent-graft positions in 20 patients presenting complex anatomies. High endoprosthesis appositions were observed. This shows the potential of computer simulation to anticipate endoprosthesis proximal sealing complications such as endoleaks and migration before intervention.
Collapse
Affiliation(s)
- Lucie Derycke
- University Paris Saclay, INSERM UMR S-999, F-92350, Le Plessis Robinson, France; Department of Vascular Surgery, Hôpital Paris Saint-Joseph, F-75014, Paris, France.
| | - Stéphane Avril
- Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023, Saint-Etienne, France
| | | | - Jean-Noël Albertini
- Vascular and endovascular Surgery Department, Saint-Joseph Hospital, F-13008, Marseille, France
| | - Antoine Millon
- Department of Vascular and Endovascular Surgery, Hospices Civils de Lyon, Louis Pradel University, F-69500, Bron, France
| |
Collapse
|
2
|
Rolf-Pissarczyk M, Schussnig R, Fries TP, Fleischmann D, Elefteriades JA, Humphrey JD, Holzapfel GA. Mechanisms of aortic dissection: From pathological changes to experimental and in silico models. PROGRESS IN MATERIALS SCIENCE 2025; 150:101363. [PMID: 39830801 PMCID: PMC11737592 DOI: 10.1016/j.pmatsci.2024.101363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
Abstract
Aortic dissection continues to be responsible for significant morbidity and mortality, although recent advances in medical data assimilation and in experimental and in silico models have improved our understanding of the initiation and progression of the accumulation of blood within the aortic wall. Hence, there remains a pressing necessity for innovative and enhanced models to more accurately characterize the associated pathological changes. Early on, experimental models were employed to uncover mechanisms in aortic dissection, such as hemodynamic changes and alterations in wall microstructure, and to assess the efficacy of medical implants. While experimental models were once the only option available, more recently they are also being used to validate in silico models. Based on an improved understanding of the deteriorated microstructure of the aortic wall, numerous multiscale material models have been proposed in recent decades to study the state of stress in dissected aortas, including the changes associated with damage and failure. Furthermore, when integrated with accessible patient-derived medical data, in silico models prove to be an invaluable tool for identifying correlations between hemodynamics, wall stresses, or thrombus formation in the deteriorated aortic wall. They are also advantageous for model-guided design of medical implants with the aim of evaluating the deployment and migration of implants in patients. Nonetheless, the utility of in silico models depends largely on patient-derived medical data, such as chosen boundary conditions or tissue properties. In this review article, our objective is to provide a thorough summary of medical data elucidating the pathological alterations associated with this disease. Concurrently, we aim to assess experimental models, as well as multiscale material and patient data-informed in silico models, that investigate various aspects of aortic dissection. In conclusion, we present a discourse on future perspectives, encompassing aspects of disease modeling, numerical challenges, and clinical applications, with a particular focus on aortic dissection. The aspiration is to inspire future studies, deepen our comprehension of the disease, and ultimately shape clinical care and treatment decisions.
Collapse
Affiliation(s)
| | - Richard Schussnig
- High-Performance Scientific Computing, University of Augsburg, Germany
- Institute of Structural Analysis, Graz University of Technology, Austria
| | - Thomas-Peter Fries
- Institute of Structural Analysis, Graz University of Technology, Austria
| | - Dominik Fleischmann
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, USA
| | | | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, USA
| | - Gerhard A. Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
3
|
Żołnierczuk M, Rynio P, Rybicka A, Głowiński J, Milnerowicz A, Pormanczuk K, Kostka A, Oszkinis G, Hobot J, Gutowski P, Kazimierczak A. Initial Multicenter Experience With the New Castor Arch Branched Device in Europe: A Middle-term Results Study. J Endovasc Ther 2024:15266028241304307. [PMID: 39665395 DOI: 10.1177/15266028241304307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2024]
Abstract
BACKGROUND Published reports demonstrate that the use of Castor stent-graft is a promising treatment of aortic pathologies with the need to land in zone 2. However, there is a lack of publications on the medium-term results of Castor in the European population. This research evaluates the mid-term results of the Castor stent-graft in several Polish centers for the treatment of aortic pathologies and enriches the current knowledge of Castor stent-grafts. MATERIAL AND METHODS Twenty-one patients from 5 polish vascular surgery centers in subacute phase of type B aortic dissection (TBAD) with at least 1 classic risk factor of aneurysmatic degeneration, thoracic aortic aneurysms (TAAs) exceeding 5.5 cm, subacute phase of intramural hematomas (IMHs) and penetrating aortic ulcerations (PAUs) with at least 1 indication to endovascular treatment. Structure of the aortic arch and factors of aneurysmal degeneration for TBAD were highlighted. Early complications, long-term complications, and reinterventions after Castor device implantation are reported in the study. RESULTS Twenty (95.24%) patients survived, of which a technical success involving implantation of the Castor device in the correct location with a patent branch for the left subclavian artery, and no endoleaks were noted in 19 (90.48%) patients. After the procedure, there were 2 (9.52%) cases of type I endoleak (in which technical success was not achieved) and 2 (9.52%) cases of bird beak. In addition, 1 case of access site hematoma, 1 case of pseudoaneurysm, and 1 case of access iliac artery rupture requiring implantation of a Viabahn device were observed. During the follow-up period (mean 14 months; range = 1-40 months), 1 patient required reintervention due to type I endoleak and 1 patient due to left subclavian artery (LSA) branch thrombosis. Two patients required subsequent branched endovascular aortic repair procedure due to unfavorable remodeling and fast aneurysm formation in visceral aorta, regardless of Castor results. CONCLUSION The Castor device is an easy-to-use stent-graft with good medium-term results. It is an excellent option in cases requiring LSA revascularization during TEVAR. CLINICAL IMPACT In this study, we investigate the medium-term results of the Castor stent graft in patients with type B aortic dissection, thoracic aortic aneurysm, intramural hematoma and penetrating aortic ulceration. The medium-term results of treatment with the Castor device are not yet well studied. Currently, there are only a small number of publications on the safety, complications and success of Castor device implantation.
Collapse
Affiliation(s)
- Michał Żołnierczuk
- Department of Vascular Surgery, General Surgery and Angiology, Pomeranian Medical University, Szczecin, Poland
| | - Paweł Rynio
- Department of Vascular Surgery, General Surgery and Angiology, Pomeranian Medical University, Szczecin, Poland
| | - Anita Rybicka
- Department of Nursing, Faculty of Health Sciences, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Jerzy Głowiński
- Department of Vascular Surgery and Transplantation, Medical University of Bialystok, Bialystok, Poland
| | - Artur Milnerowicz
- Department of Vascular Surgery, Transplantology and Liver Surgery, Fourth Military Clinical Hospital With Polyclinic, Wroclaw, Poland
| | - Kornel Pormanczuk
- Department of Vascular Surgery, Transplantology and Liver Surgery, Fourth Military Clinical Hospital With Polyclinic, Wroclaw, Poland
- Department of Preclinical Sciences, Pharmacology and Medical Diagnostics, Faculty of Medicine, University of Science and Technology, Wroclaw, Poland
| | - Andrzej Kostka
- Department of Vascular Surgery, University Hospital in Krakow, Krakow, Poland
| | - Grzegorz Oszkinis
- Department of General and Vascular Surgery, University of Opole, Opole, Poland
| | - Jacek Hobot
- Department of General and Vascular Surgery, University of Opole, Opole, Poland
| | - Piotr Gutowski
- Department of Vascular Surgery, General Surgery and Angiology, Pomeranian Medical University, Szczecin, Poland
| | - Arkadiusz Kazimierczak
- Department of Vascular Surgery, General Surgery and Angiology, Pomeranian Medical University, Szczecin, Poland
| |
Collapse
|
4
|
Derycke L, Avril S, Vermunt J, Perrin D, El Batti S, Alsac JM, Albertini JN, Millon A. Computational prediction of proximal sealing in endovascular abdominal aortic aneurysm repair with unfavorable necks. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107993. [PMID: 38142515 DOI: 10.1016/j.cmpb.2023.107993] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 12/20/2023] [Accepted: 12/20/2023] [Indexed: 12/26/2023]
Abstract
BACKGROUND AND OBJECTIVE Endovascular aortic aneurysm repair (EVAR) has become the standard treatment for abdominal aortic aneurysms in most centers. However, proximal sealing complications leading to endoleaks and migrations sometimes occur, particularly in unfavorable aortic anatomies and are strongly dependent on biomechanical interactions between the aortic wall and the endograft. The objective of the present work is to develop and validate a computational patient-specific model that can accurately predict these complications. METHODS Based on pre-operative CT-scans, we developed finite element models of the aorta of 10 patients who underwent endovascular aortic aneurysm repair, 7 with standard morphologies and 3 with unfavorable anatomies. We simulated the deployment of stent grafts in each aorta by solving mechanical equilibrium with a virtual shell method. Eventually we compared the actual stent ring positions from post-operative computed-tomography-scans with the predicted simulated positions. RESULTS A successful deployment simulation could be performed for each patient. Relative radial, transverse and longitudinal deviations were 6.3 ± 4.4%, 2.5 ± 0.9 mm and 1.4 ± 1.1 mm, respectively. CONCLUSIONS The numerical model predicted accurately stent-graft positions in the aortic neck of 10 patients, even in complex anatomies. This shows the potential of computer simulation to anticipate possible proximal endoleak complications before EVAR interventions.
Collapse
Affiliation(s)
- L Derycke
- Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France; Department of Vascular Surgery, Hôpital Paris Saint-Joseph, F-75014 Paris, France
| | - S Avril
- Mines Saint-Etienne, Université Jean Monnet Saint-Etienne, INSERM, SAINBIOSE U1059, F-42023 Saint-Etienne, France.
| | | | | | - S El Batti
- Department of Cardio-Vascular and Vascular Surgery, Hôpital Européen Georges Pompidou, F-75015 Paris, France
| | - J-M Alsac
- Department of Cardio-Vascular and Vascular Surgery, Hôpital Européen Georges Pompidou, F-75015 Paris, France
| | | | - A Millon
- Department of Vascular and Endovascular Surgery, Hospices Civils de Lyon, Louis Pradel University, Hospital, F-69500 Bron, France
| |
Collapse
|
5
|
Luan J, Qiao Y, Mao L, Fan J, Zhu T, Luo K. The role of aorta distal to stent in the occurrence of distal stent graft-induced new entry tear: A computational fluid dynamics and morphological study. Comput Biol Med 2023; 166:107554. [PMID: 37839217 DOI: 10.1016/j.compbiomed.2023.107554] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 09/04/2023] [Accepted: 09/28/2023] [Indexed: 10/17/2023]
Abstract
Distal stent graft-induced new entry tear (dSINE) is an important complication of thoracic endovascular aortic repair (TEVAR) for the treatment of type B aortic dissection (TBAD). This study aims to explore whether the aorta distal to the stent plays an important role in the occurrence of dSINE. Sixty-nine patient-specific geometrical models of twenty-three enrolled patients were reconstructed from preoperative, postoperative, and predSINE computed tomography scans. Computational fluid dynamics (CFD) simulations were performed to calculate the von Mises stress in the CFD group. Meanwhile, morphological measurements were performed in all patients, including measurements of the inverted pyramid index at different follow-up time points and the postoperative true lumen volume change rate. In the CFD study, the time-averaged von Mises stress of the true lumen distal to the stent in dSINE patients was significantly higher than that in the CFD controls (20.42 kPa vs. 15.47 kPa). In the morphological study, a special aortic plane (plane A) with an extremely small area distal to the stent was observed in dSINE patients, which resulted in an inverted pyramid structure in the true lumen distal to the stent. This structure in dSINE patients became increasingly obvious during the follow-up period and finally reached the maximum value before dSINE occurred (mean, 3.91 vs. 1.23). At the same time, enlargement of the true lumen distal to the stent occurs before dSINE, manifesting as a continuous increase in the true lumen volume (mean, 0.70 vs. 013). A new theory of what causes dSINE to occur has been proposed: the inverted pyramid structure of the true lumen distal to the stent caused an increase in the von Mises stress in this region and aortic enlargement, which ultimately led to the occurrence of dSINE.
Collapse
Affiliation(s)
- Jingyang Luan
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yonghui Qiao
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China
| | - Le Mao
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Jianren Fan
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China; Shanghai Institute for Advanced Study of Zhejiang University, Shanghai, China
| | - Ting Zhu
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China.
| | - Kun Luo
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China; Shanghai Institute for Advanced Study of Zhejiang University, Shanghai, China.
| |
Collapse
|
6
|
Rapid Morphological Measurement Method of Aortic Dissection Stent Based on Spatial Observation Point Set. Bioengineering (Basel) 2023; 10:bioengineering10020139. [PMID: 36829632 PMCID: PMC9951888 DOI: 10.3390/bioengineering10020139] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 01/12/2023] [Accepted: 01/12/2023] [Indexed: 01/22/2023] Open
Abstract
OBJECTIVES Post-operative stent morphology of aortic dissection patients is important for performing clinical diagnosis and prognostic assessment. However, stent morphologies still need to be manually measured, which is a process prone to errors, high time consumption and difficulty in exploiting inter-data associations. Herein, we propose a method based on the stepwise combination of basic, non-divisible data sets to quickly obtain morphological parameters with high accuracy. METHODS We performed the 3D reconstruction of 109 post-operative follow-up CT image data from 26 patients using mimics software. By extracting the spatial locations of the basic morphological observation points on the stent, we defined a basic and non-reducible set of observation points. Further, we implemented a fully automatic stent segmentation and an observation point extraction algorithm. We analyzed the stability and accuracy of the algorithms on a test set containing 8 cases and 408 points. Based on this dataset, we calculated three morphological parameters of different complexity for the different spatial structural features exhibited by the stent. Finally, we compared the two measurement schemes in four aspects: data variability, data stability, statistical process complexity and algorithmic error. RESULTS The statistical results of the two methods on two low-complexity morphological parameters (spatial position of stent end and vascular stent end-slip volume) show good agreement (n = 26, P1, P2 < 0.001, r1 = 0.992, r2 = 0.988). The statistics of the proposed method for the morphological parameters of medium complexity (proximal support ring feature diameter and distal support ring feature diameter) avoid the errors caused by manual extraction, and the magnitude of this correction to the traditional method does not exceed 4 mm with an average correction of 1.38 mm. Meanwhile, our proposed automatic observation point extraction method has only 2.2% error rate on the test set, and the average spatial distance from the manually marked observation points is 0.73 mm. Thus, the proposed method is able to rapidly and accurately measure the stent circumferential deflection angle, which is highly complex and cannot be measured using traditional methods. CONCLUSIONS The proposed method can significantly reduce the statistical observation time and information processing cost compared to the traditional morphological observation methods. Moreover, when new morphological parameters are required, one can quickly and accurately obtain the target parameters by new "combinatorial functions." Iterative modification of the data set itself is avoided.
Collapse
|
7
|
Liu Y, Qing M, Zhao J, Huang B, Yang Y, Zheng T, Yuan D. Influence of severe neck angulation on hemodynamic and clinical outcomes following endovascular aneurysm repair: a hemodynamic analysis and a retrospective cohort study. Chin Med J (Engl) 2022; 135:2577-2584. [PMID: 36583921 PMCID: PMC9943978 DOI: 10.1097/cm9.0000000000002280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND For patients with severe neck angulation (SNA), hemodynamic and clinical outcomes following endovascular aneurysm repair (EVAR) are still unclear. This study aimed to explore the influence of SNA on hemodynamic and clinical outcomes following EVAR. METHODS This study included a hemodynamic analysis and a retrospective cohort study from West China Hospital of Sichuan University between January 2011 and December 2020. The Cox regression model, inverse probability of treatment weighting (IPTW) analysis, sensitivity analysis, and subgroup analysis were applied. Primary outcome was type IA endoleak (T1AEL). RESULTS In this hemodynamic analysis, nine non-severe neck angulation (nSNA) and 16 SNA idealized models were constructed. We found a significant difference in drag force between SNA and nSNA models (7.016 ± 2.579 N vs. 4.283 ± 1.460 N, P = 0.008), and proximal neck angles were significantly associated with the magnitude of drag force (F = 0.082 × α-0.006 × β + 2.818, α: 95% confidence interval [CI] 0.070-0.094; P = 0.001; β: 95% CI -0.019 to 0.007; P = 0.319). In our cohort study, 514 nSNA patients (71.5 ± 8.5 years; 459 males) and 208 SNA patients (72.5 ± 7.8 years; 135 males) were included, with a median follow-up duration of 34 months (16-63 months). All baseline characteristics were well balanced after IPTW matching. We found that SNA was associated with a significant risk of adverse limb event (hazard ratio [HR] 2.18, 95% CI 1.09-3.12), yet was not associated with T1AEL, overall survival, or reintervention. In patients without proximal or distal additional procedures (DAP), subgroup analyses suggested a significant risk of T1AEL (Proximal: HR 5.25, 95% CI 1.51-18.23; Distal: HR 5.07, 95% CI 1.60-16.07) and adverse limb event (Proximal: HR 2.27, 95% CI 1.01-5.07; Distal: HR 2.91, 95% CI 1.30-6.54) in SNA patients. However, no noticeable difference was observed in patients with proximal or DAP. CONCLUSIONS SNA has a critical influence on hemodynamic and clinical outcomes following EVAR. Appropriate additional procedures may be of great benefit to SNA patients.
Collapse
Affiliation(s)
- Yang Liu
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Ming Qing
- Department of Applied Mechanics, Sichuan University, Chengdu, Sichuan 610065, China
| | - Jichun Zhao
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Bin Huang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Yi Yang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, Chengdu, Sichuan 610065, China
| | - Ding Yuan
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan 610041, China
| |
Collapse
|
8
|
Williamson PN, Docherty PD, Yazdi SG, Khanafer A, Kabaliuk N, Jermy M, Geoghegan PH. Review of the Development of Hemodynamic Modeling Techniques to Capture Flow Behavior in Arteries Affected by Aneurysm, Atherosclerosis, and Stenting. J Biomech Eng 2022; 144:1128816. [PMID: 34802061 DOI: 10.1115/1.4053082] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Indexed: 02/05/2023]
Abstract
Cardiovascular diseases (CVDs) are the leading cause of death in the developed world. CVD can include atherosclerosis, aneurysm, dissection, or occlusion of the main arteries. Many CVDs are caused by unhealthy hemodynamics. Some CVDs can be treated with the implantation of stents and stent grafts. Investigations have been carried out to understand the effects of stents and stent grafts have on arteries and the hemodynamic changes post-treatment. Numerous studies on stent hemodynamics have been carried out using computational fluid dynamics (CFD) which has yielded significant insight into the effect of stent mesh design on near-wall blood flow and improving hemodynamics. Particle image velocimetry (PIV) has also been used to capture behavior of fluids that mimic physiological hemodynamics. However, PIV studies have largely been restricted to unstented models or intra-aneurysmal flow rather than peri or distal stent flow behaviors. PIV has been used both as a standalone measurement method and as a comparison to validate the CFD studies. This article reviews the successes and limitations of CFD and PIV-based modeling methods used to investigate the hemodynamic effects of stents. The review includes an overview of physiology and relevant mechanics of arteries as well as consideration of boundary conditions and the working fluids used to simulate blood for each modeling method along with the benefits and limitations introduced.
Collapse
Affiliation(s)
- Petra N Williamson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Sina G Yazdi
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Adib Khanafer
- Vascular, Endovascular, and Renal Transplant Unit, Christchurch Hospital, Canterbury District Health Board, Riccarton Avenue, Christchurch 8053, New Zealand; Christchurch School of Medicine, University of Otago, Dunedin 9016, New Zealand
| | - Natalia Kabaliuk
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Mark Jermy
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Patrick H Geoghegan
- School of Life and Health Sciences, Aston University, Birmingham B4 7ET, UK; Department of Mechanical and Industrial Engineering, University of South Africa, Johannesburg 2006, South Africa
| |
Collapse
|
9
|
Li Z, Chen Z, Gao Y, Xing Y, Zhou Y, Luo Y, Xu W, Chen Z, Gao X, Gupta K, Anbalakan K, Chen L, Liu C, Kong J, Leo HL, Hu C, Yu H, Guo Q. Shape memory micro-anchors with magnetic guidance for precision micro-vascular deployment. Biomaterials 2022; 283:121426. [DOI: 10.1016/j.biomaterials.2022.121426] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 01/21/2022] [Accepted: 02/17/2022] [Indexed: 12/28/2022]
|
10
|
Haemodynamic Analysis of Branched Endografts for Complex Aortic Arch Repair. Bioengineering (Basel) 2022; 9:bioengineering9020045. [PMID: 35200399 PMCID: PMC8868591 DOI: 10.3390/bioengineering9020045] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 01/11/2022] [Accepted: 01/13/2022] [Indexed: 11/17/2022] Open
Abstract
This study aims to investigate the haemodynamic response induced by implantation of a double-branched endograft used in thoracic endovascular aortic repair (TEVAR) of the aortic arch. Anatomically realistic models were reconstructed from CT images obtained from patients who underwent TEVAR using the RelayPlus double-branched endograft implanted in the aortic arch. Two cases (Patient 1, Patient 2) were included here, both patients presented with type A aortic dissection before TEVAR. To examine the influence of inner tunnel branch diameters on localised flow patterns, three tunnel branch diameters were tested using the geometric model reconstructed for Patient 1. Pulsatile blood flow through the models was simulated by numerically solving the Navier–Stokes equations along with a transitional flow model. The physiological boundary conditions were imposed at the model inlet and outlets, while the wall was assumed to be rigid. Our simulation results showed that the double-branched endograft allowed for the sufficient perfusion of blood to the supra-aortic branches and restored flow patterns expected in normal aortas. The diameter of tunnel branches in the device plays a crucial role in the development of flow downstream of the branches and thus must be selected carefully based on the overall geometry of the vessel. Given the importance of wall shear stress in vascular remodelling and thrombus formation, longitudinal studies should be performed in the future in order to elucidate the role of tunnel branch diameters in long-term patency of the supra-aortic branches following TEVAR with the double-branched endograft.
Collapse
|
11
|
Qing M, Qiu Y, Wang J, Zheng T, Yuan D. A Comparative Study on the Hemodynamic Performance Within Cross and Non-cross Stent-Grafts for Abdominal Aortic Aneurysms With an Angulated Neck. Front Physiol 2021; 12:795085. [PMID: 34925075 PMCID: PMC8674644 DOI: 10.3389/fphys.2021.795085] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 11/10/2021] [Indexed: 02/05/2023] Open
Abstract
Objectives: Cross-limb stent grafts for endovascular aneurysm repair (EVAR) are often employed for abdominal aortic aneurysms (AAAs) with significant aortic neck angulation. Neck angulation may be coronal or sagittal; however, previous hemodynamic studies of cross-limb EVAR stent grafts (SGs) primarily utilized simplified planar neck geometries. This study examined the differences in flow patterns and hemodynamic parameters between crossed and non-crossed limb SGs at different spatial neck angulations. Methods: Ideal models consisting of 13 cross and 13 non-cross limbs were established, with coronal and sagittal angles ranging from 0 to 90°. Computational fluid dynamics (CFD) was used to capture the hemodynamic information, and the differences were compared. Results: With regards to the pressure drop index, the maximum difference caused by the configuration and angular direction was 4.6 and 8.0%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 27.1%. With regards to the SAR-TAWSS index, the maximum difference caused by the configuration and angular direction was 7.8 and 9.8%, respectively, but the difference resulting from the change in aneurysm neck angle can reach 26.7%. In addition, when the aneurysm neck angle is lower than 45°, the configuration and angular direction significantly influence the OSI and helical flow intensity index. However, when the aneurysm neck angle is greater than 45°, the hemodynamic differences of each model at the same aneurysm neck angle are reduced. Conclusion: The main factor affecting the hemodynamic index was the angle of the aneurysm neck, while the configuration and angular direction had little effect on the hemodynamics. Furthermore, when the aneurysm neck was greatly angulated, the cross-limb technique did not increase the risk of thrombosis.
Collapse
Affiliation(s)
- Ming Qing
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,Yibin Institute of Industrial Technology/Sichuan University Yibin Park, Yibin, China
| | - Yue Qiu
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China
| | - Jiarong Wang
- Department of Vascular Surgery, West China Hospital, Sichuan University, Chengdu, China
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, Chengdu, China.,Med-X Center for Informatics, Sichuan University, Chengdu, China
| | - Ding Yuan
- West China Biomedical Big Data Center, West China Hospital, Sichuan University, Chengdu, China.,Med-X Center for Informatics, Sichuan University, Chengdu, China
| |
Collapse
|
12
|
Avril S, Gee MW, Hemmler A, Rugonyi S. Patient-specific computational modeling of endovascular aneurysm repair: State of the art and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3529. [PMID: 34490740 DOI: 10.1002/cnm.3529] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 08/30/2021] [Indexed: 06/13/2023]
Abstract
Endovascular aortic repair (EVAR) has become the preferred intervention option for aortic aneurysms and dissections. This is because EVAR is much less invasive than the alternative open surgery repair. While in-hospital mortality rates are smaller for EVAR than open repair (1%-2% vs. 3%-5%), the early benefits of EVAR are lost after 3 years due to larger rates of complications in the EVAR group. Clinicians follow instructions for use (IFU) when possible, but are left with personal experience on how to best proceed and what choices to make with respect to stent-graft (SG) model choice, sizing, procedural options, and their implications on long-term outcomes. Computational modeling of SG deployment in EVAR and tissue remodeling after intervention offers an alternative way of testing SG designs in silico, in a personalized way before intervention, to ultimately select the strategies leading to better outcomes. Further, computational modeling can be used in the optimal design of SGs in cases of complex geometries. In this review, we address some of the difficulties and successes associated with computational modeling of EVAR procedures. There is still work to be done in all areas of EVAR in silico modeling, including model validation, before models can be applied in the clinic, but much progress has already been made. Critical to clinical implementation are current efforts focusing on developing fast algorithms that can achieve (near) real-time solutions, as well as ways of dealing with inherent uncertainties related to patient aortic wall degradation on an individualized basis. We are optimistic that EVAR modeling in the clinic will soon become a reality to help clinicians optimize EVAR interventions and ultimately reduce EVAR-associated complications.
Collapse
Affiliation(s)
- Stéphane Avril
- Mines Saint-Étienne, Univ Lyon, Univ Jean Monnet, INSERM, Saint-Étienne, France
| | - Michael W Gee
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - André Hemmler
- Mechanics & High Performance Computing Group, Department of Mechanical Engineering, Technical University of Munich, Garching, Germany
| | - Sandra Rugonyi
- Biomedical Engineering Department, Oregon Health & Science University, Portland, Oregon, USA
| |
Collapse
|
13
|
Qiao Y, Mao L, Ding Y, Zhu T, Luo K, Fan J. Fluid-structure interaction: Insights into biomechanical implications of endograft after thoracic endovascular aortic repair. Comput Biol Med 2021; 138:104882. [PMID: 34600328 DOI: 10.1016/j.compbiomed.2021.104882] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 09/04/2021] [Accepted: 09/19/2021] [Indexed: 10/20/2022]
Abstract
Thoracic endovascular aortic repair (TEVAR) has developed to be the most effective treatment for aortic diseases. This study aims to evaluate the biomechanical implications of the implanted endograft after TEVAR. We present a novel image-based, patient-specific, fluid-structure computational framework. The geometries of blood, endograft, and aortic wall were reconstructed based on clinical images. Patient-specific measurement data was collected to determine the parameters of the three-element Windkessel. We designed three postoperative scenarios with rigid wall assumption, blood-wall interaction, blood-endograft-wall interplay, respectively, where a two-way fluid-structure interaction (FSI) method was applied to predict the deformation of the composite stent-wall. Computational results were validated with Doppler ultrasound data. Results show that the rigid wall assumption fails to predict the waveforms of blood outflow and energy loss (EL). The complete storage and release process of blood flow energy, which consists of four phases is captured by the FSI method. The endograft implantation would weaken the buffer function of the aorta and reduce mean EL by 19.1%. The closed curve area of wall pressure and aortic volume could indicate the EL caused by the interaction between blood flow and wall deformation, which accounts for 68.8% of the total EL. Both the FSI and endograft have a slight effect on wall shear stress-related-indices. The deformability of the composite stent-wall region is remarkably limited by the endograft. Our results highlight the importance of considering the interaction between blood flow, the implanted endograft, and the aortic wall to acquire physiologically accurate hemodynamics in post-TEVAR computational studies and the deformation of the aortic wall is responsible for the major EL of the blood flow.
Collapse
Affiliation(s)
- Yonghui Qiao
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China
| | - Le Mao
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Ying Ding
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Ting Zhu
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Kun Luo
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China.
| | - Jianren Fan
- State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, China.
| |
Collapse
|
14
|
Dai Y, Hu H, Wang J, Yuan D, Zheng T. Design and mechanical properties testing of a new cross-helical popliteal artery stent. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2021. [DOI: 10.1016/j.medntd.2021.100089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
15
|
Kyriakou F, Maclean C, Dempster W, Nash D. Efficiently Simulating an Endograft Deployment: A Methodology for Detailed CFD Analyses. Ann Biomed Eng 2020; 48:2449-2465. [PMID: 32394221 PMCID: PMC7505889 DOI: 10.1007/s10439-020-02519-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 04/24/2020] [Indexed: 01/10/2023]
Abstract
Numerical models of endografts for the simulation of endovascular aneurysm repair are increasingly important in the improvement of device designs and patient outcomes. Nevertheless, current finite element analysis (FEA) models of complete endograft devices come at a high computational cost, requiring days of runtime, therefore restricting their applicability. In the current study, an efficient FEA model of the Anaconda™ endograft (Terumo Aortic, UK) was developed, able to yield results in just over 4 h, an order of magnitude less than similar models found in the literature. The model was used to replicate a physical device that was deployed in a 3D printed aorta and comparison of the two shapes illustrated a less than 5 mm placement error of the model in the regions of interest, consistent with other more computationally intensive models in the literature. Furthermore, the final goal of the study was to utilize the deployed fabric model in a hemodynamic analysis that would incorporate realistic fabric folds, a feature that is almost always omitted in similar simulations. By successfully exporting the deployed graft geometry into a flow analysis, it was illustrated that the inclusion of fabric wrinkles enabled clinically significant flow patterns such as flow stagnation and recirculation to be detected, paving the way for this modelling methodology to be used in future for stent design optimisation.
Collapse
Affiliation(s)
- Faidon Kyriakou
- Department of Mechanical and Aerospace Engineering, University of Strathclyde, 75 Montrose Street, Glasgow, G1 1XJ, UK.
| | | | - William Dempster
- Department of Mechanical and Aerospace Engineering, University of Strathclyde, 75 Montrose Street, Glasgow, G1 1XJ, UK
| | - David Nash
- Department of Mechanical and Aerospace Engineering, University of Strathclyde, 75 Montrose Street, Glasgow, G1 1XJ, UK
| |
Collapse
|
16
|
Edlin J, Youssefi P, Bilkhu R, Figueroa CA, Morgan R, Nowell J, Jahangiri M. Haemodynamic assessment of bicuspid aortic valve aortopathy: a systematic review of the current literature. Eur J Cardiothorac Surg 2020; 55:610-617. [PMID: 30239633 DOI: 10.1093/ejcts/ezy312] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 08/09/2018] [Accepted: 08/15/2018] [Indexed: 11/12/2022] Open
Abstract
Both genetic and haemodynamic theories explain the aetiology, progression and optimal management of bicuspid aortic valve aortopathy. In recent years, the haemodynamic theory has been explored with the help of magnetic resonance imaging and computational fluid dynamics. The objective of this review was to summarize the findings of these investigations with focus on the blood flow pattern and associated variables, including flow eccentricity, helicity, flow displacement, cusp opening angle, systolic flow angle, wall shear stress (WSS) and oscillatory shear index. A structured literature review was performed from January 1990 to January 2018 and revealed the following 3 main findings: (i) the bicuspid aortic valve is associated with flow eccentricity and helicity in the ascending aorta compared to healthy and diseased tricuspid aortic valve, (ii) flow displacement is easier to obtain than WSS and has been shown to correlate with valve morphology and type of aortopathy and (iii) the stenotic bicuspid aortic valve is associated with elevated WSS along the greater curvature of the ascending aorta, where aortic dilatation and aortic wall thinning are commonly found. We conclude that new haemodynamic variables should complement ascending aorta diameter as an indicator for disease progression and the type and timing of intervention. WSS describes the force that blood flow exerts on the vessel wall as a function of viscosity and geometry of the vessel, making it a potentially more reliable marker of disease progression.
Collapse
Affiliation(s)
- Joy Edlin
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Pouya Youssefi
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Rajdeep Bilkhu
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Carlos Alberto Figueroa
- Department of Biomedical Engineering, King's College London, London, UK.,Department of Surgery, University of Michigan, Ann Arbor, MI, USA
| | - Robert Morgan
- Department of Radiology, St George's Hospital, London, UK
| | - Justin Nowell
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| | - Marjan Jahangiri
- Department of Cardiothoracic Surgery, St George's Hospital, London, UK
| |
Collapse
|
17
|
Meng Z, Ma T, Cai Y, Liu X, Wang S, Dong Z, Fu W. Numerical modeling and simulations of type B aortic dissection treated by stent-grafts with different oversizing ratios. Artif Organs 2020; 44:1202-1210. [PMID: 32530055 DOI: 10.1111/aor.13750] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 05/13/2020] [Accepted: 06/05/2020] [Indexed: 11/28/2022]
Abstract
Retrograde type A dissection after thoracic endovascular aortic repair has been a major drawback of endovascular treatment. This study investigated the biomechanical mechanism of stent-graft-induced new lesions after implantation and analyzed the relationship between radial force and spring-back force of the stent-graft when it was implanted virtually under different oversizing ratios. Based on the computed tomography angiography images, a three-dimensional geometric model of a patient-specific aortic dissection was established. The stent was designed in CAD software and the stent-graft implantation procedure under different oversizing ratios was simulated in the finite element analysis software. Implantation simulations were performed six times for each stent-graft model under 0%, 3%, 6%, 9%, 12%, and 15% oversizing ratios and the peak stress of the aorta was compared among groups. It was observed that the peak stress of the aorta was located where the proximal bare stent interacted with aortic wall and its value was increased by 62.2% from 0% to 15% oversizing ratio. The conclusions are reached that the long-term higher stress in the aortic wall may lead to the emergence of new lesions in these areas, and the radial force plays a key role in the formation of a new entry in the real aorta model.
Collapse
Affiliation(s)
- Zhuangyuan Meng
- Department of Aeronautics and Astronautics, Fudan University, Shanghai, China
| | - Tao Ma
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Yunhan Cai
- Department of Aeronautics and Astronautics, Fudan University, Shanghai, China
| | - Xudong Liu
- Department of Aeronautics and Astronautics, Fudan University, Shanghai, China
| | - Shengzhang Wang
- Department of Aeronautics and Astronautics, Fudan University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Weiguo Fu
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
18
|
Raptis A, Xenos M, Spanos K, Kouvelos G, Giannoukas A, Matsagkas M. Endograft Specific Haemodynamics After Endovascular Aneurysm Repair: Flow Characteristics of Four Stent Graft Systems. Eur J Vasc Endovasc Surg 2019; 58:538-547. [PMID: 31431336 DOI: 10.1016/j.ejvs.2019.04.017] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Revised: 09/09/2018] [Accepted: 04/14/2019] [Indexed: 10/26/2022]
Abstract
OBJECTIVES The implication of haemodynamics in the occurrence of complications after endovascular aneurysm repair (EVAR) has been raised in the literature. Different aortic stent graft configurations may lead to different haemodynamic properties. The current study deals with the post-operative haemodynamic variability between four stent graft systems with different structure, material, and type of fixation. METHODS Computed tomography data of 32 patients were used, equally distributed among the four endograft groups, namely the AFX, Endurant, Excluder, and Nellix. Velocity, wall shear stress (WSS), and helicity statistics were calculated, in regions around the flow division where disturbances are expected. The haemodynamic data were compared between and within the groups. RESULTS The morphology of AAAs pre-operatively did not vary significantly among the four groups. Before the flow division, lowest velocity was observed in Endurant cases and highest in Nellix cases. Endurant induced the lowest peak WSS and Nellix the highest (p = .03). The helicity levels were low in AFX and Nellix cases and high in Endurant and Excluder cases. After the flow division, the trend in the results was preserved. Nellix induced the highest velocity and WSS, followed closely by Excluder and AFX. There was a significant increase of helicity before and after flow division in AFX (p <0.001, R2 = 0.09) and Nellix (p <0.001) cases. CONCLUSIONS It has been shown that different types of endografts induce variable haemodynamic conditions around the flow division. The parallel limb structure, featured by Nellix, seems to induce favourable flow conditions in terms of velocity and WSS, while helical flow before the flow division is suppressed. High WSS is generally considered to be a desirable flow characteristic in endovascular devices, whereas helicity extremes (very low or high) are potentially a negative sign. Endurant, with the stiffer material and the short neck structure, was associated with the lowest blood velocity and WSS values but preserved high helicity levels. The AFX and Excluder, which include the same material, induced similar haemodynamic conditions.
Collapse
Affiliation(s)
- Anastasios Raptis
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece
| | - Michalis Xenos
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Mathematics, University of Ioannina, Ioannina, Greece
| | - Konstantinos Spanos
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - George Kouvelos
- Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Athanasios Giannoukas
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Miltiadis Matsagkas
- Laboratory for Vascular Simulations, Institute of Vascular Diseases, Larissa, Greece; Department of Vascular Surgery, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece.
| |
Collapse
|
19
|
Nasr B, Savean J, Albert B, Badra A, Braesco J, Nonent M, Gouny P, Visvikis D, Fayad H. Thoracic Stent-Graft Migration: The Role of the Geometric Modifications of the Stent-Graft at 3 years. Ann Vasc Surg 2019; 58:16-23. [DOI: 10.1016/j.avsg.2018.10.024] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 10/08/2018] [Accepted: 10/10/2018] [Indexed: 10/27/2022]
|
20
|
Asenbaum U, Schoder M, Schwartz E, Langs G, Baltzer P, Wolf F, Prusa AM, Loewe C, Nolz R. Stent-graft surface movement after endovascular aneurysm repair: baseline parameters for prediction, and association with migration and stent-graft-related endoleaks. Eur Radiol 2019; 29:6385-6395. [PMID: 31250169 PMCID: PMC6828830 DOI: 10.1007/s00330-019-06282-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 04/25/2019] [Accepted: 05/22/2019] [Indexed: 12/31/2022]
Abstract
OBJECTIVES To evaluate the influence of baseline parameters on the occurrence of stent-graft surface movement after endovascular aneurysm repair (EVAR) and to investigate its association with migration and stent-graft-related endoleaks (srEL). METHODS In this retrospective, cross-sectional study, three-dimensional surface models of the stent-graft, delimited by landmarks using custom-built software, were derived from the pre-discharge and last follow-up computed tomography angiography (CTA). Stent-graft surface movement in the proximal anchoring zone between these examinations was considered significant at a threshold of 9 mm. The Cox proportional hazards model was used to determine baseline variables associated with the occurrence of stent-graft surface movement. The association between migration and srEL with stent-graft surface movement was tested with the chi-square and the Fisher exact test, respectively. RESULTS Stent-graft surface movement was observed in 54 (28.9%) of 187 patients. Multivariate analysis revealed that age ([HR] 1.05; p = 0.017), proximal neck diameter ([HR] 5.07; p < 0.001), infrarenal aortic neck angulation ([HR] 1.02, p = 0.002), and proximal neck length ([HR] 0.62, p < 0.001) were significantly associated with the occurrence of stent-graft surface movement. Migration and srEL occurred in 17 (31.5%) and 5 (9.3%) patients, with and 11 (8.3%) and 2 (1.5%) without stent-graft surface movement (p < 0.001, p = 0.022). CONCLUSIONS Age, neck diameter, infrarenal neck angulation, and proximal neck length were significantly associated with the occurrence of stent-graft surface movement. Apart from possible use of adjunctive sealing systems, concerned patients may benefit from regular CTA surveillance, enabling timely diagnosis of subtle changes of stent-graft position. KEY POINTS • Stent-graft surface movement, demonstrating subtle, three-dimensional changes in stent-graft position in the proximal anchoring zone, can be derived from CTA examinations. • Age, proximal neck diameter, and infrarenal neck angulation were significantly associated with an increased incidence of stent-graft surface movement. Stent-graft surface movement is significantly more frequent in patients with stent-graft migration and stent-graft-related endoleaks. • Consideration of risk factors for stent-graft surface movement may help to identify patients who might benefit from regular CTA surveillance and timely diagnosis of subtle changes of stent-graft position, enabling re-interventions to prevent migration and srEL.
Collapse
Affiliation(s)
- Ulrika Asenbaum
- Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria
| | - Maria Schoder
- Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria
| | - Ernst Schwartz
- Computational and Imaging Research Laboratory, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Georg Langs
- Computational and Imaging Research Laboratory, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Pascal Baltzer
- Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria
| | - Florian Wolf
- Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria
| | - Alexander M Prusa
- Department of Surgery, Medical University of Vienna, Vienna, Austria
| | - Christian Loewe
- Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria
| | - Richard Nolz
- Division of Cardiovascular and Interventional Radiology, Department of Bio-medical Imaging and Image-Guided Therapy, Medical University of Vienna - Vienna General Hospital, Waehringer Guertel 18-20, A-1090, Vienna, Austria.
| |
Collapse
|
21
|
Auricchio F, Conti M, Romarowski RM, de Beaufort HW, Grassi V, Trimarchi S. Computational tools for thoracic endovascular aortic repair planning. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 2019. [DOI: 10.23736/s1824-4777.18.01386-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
22
|
Numerical Modeling of Blood Flow in a Healthy Aorta and Aorta with Stent. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING 2018. [DOI: 10.4028/www.scientific.net/jbbbe.39.13] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The treatment of aortic aneurysm varies according to each patient. Stent implantation is one of many methods used to stabilize diseases. The information obtained from hemodynamic parameters in the pathological aorta with stent could help doctors in choosing the treatment before the surgery. In this context, the numerical simulation of fluid dynamics is an essential tool that can give us more detailed information that could be exploited by surgeons to find appropriate solutions to some pathologies. In this work, a study of two models of aortas: with and without stent was presented. A comparison of the results of changes in pressures and shear stresses of aortas in systolic and diastolic phases was discussed. The obtained results show a nearly similar tendency of variation for both models, which justifies the effectiveness of the type of stent chosen and its effect on the improvement of the blood flow. The methodology used in this work has revealed the detailed and necessary information for both cases studied and has shown the interest of the numerical tools for diagnosis and surgery.
Collapse
|
23
|
Lejay A, Chakfe N. Commentary on "In Vitro Evaluation of Aortic Stent Graft Deployment Accuracy in the Distal Landing Zone". Eur J Vasc Endovasc Surg 2018; 56:817. [PMID: 30172666 DOI: 10.1016/j.ejvs.2018.08.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 08/02/2018] [Indexed: 11/18/2022]
Affiliation(s)
- Anne Lejay
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, France.
| | - Nabil Chakfe
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, France
| |
Collapse
|
24
|
Belvroy VM, Houben IB, Trimarchi S, Patel HJ, Moll FL, Van Herwaarden JA. Identifying and addressing the limitations of EVAR technology. Expert Rev Med Devices 2018; 15:541-554. [PMID: 30058398 DOI: 10.1080/17434440.2018.1505496] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
INTRODUCTION Endovascular aortic repair (EVAR) has improved over the last two decades. Approximately 80% of the patients presenting with an abdominal aortic aneurysm (AAA) is nowadays primarily treated with EVAR. AREAS COVERED In this review, the differences between endovascular and open repair, the clinical characteristics needed for EVAR, the role of clinical imaging and the developments in EVAR technology will be discussed. Early mortality is lower in EVAR as compared to open repair, whereas this benefit is lost after 3 years postoperatively. EVAR comes with a high reintervention rate, with endoleak being the most important predictive factor for reintervention. Expanding technical possibilities have allowed surgeons to choose from a palate of endovascular approaches in aneurysm patients with challenging anatomies. EXPERT COMMENTARY Although EVAR has taken a giant leap forward in development, the new developments have seemed to surpass the long-term limitations with older devices. It is important to start focusing on the current limitations of EVAR, in particular the durability of devices in the human variable anatomic and dynamic environment.
Collapse
Affiliation(s)
- Viony M Belvroy
- a Department of Vascular Surgery II , Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan , Milan , Italy
| | - Ignas B Houben
- b Department of Cardiovascular Surgery , Frankel Cardiovascular Center, University of Michigan Health Center , Ann Arbor , Michigan , USA
| | - Santi Trimarchi
- a Department of Vascular Surgery II , Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan , Milan , Italy
| | - Himanshu J Patel
- b Department of Cardiovascular Surgery , Frankel Cardiovascular Center, University of Michigan Health Center , Ann Arbor , Michigan , USA
| | - Frans L Moll
- c Department of Vascular Surgery , University Medical Center Utrecht , Utrecht , the Netherlands
| | - Joost A Van Herwaarden
- c Department of Vascular Surgery , University Medical Center Utrecht , Utrecht , the Netherlands
| |
Collapse
|
25
|
Computational investigation of interaction between stent graft and aorta in retrograde type A dissection after thoracic endovascular aortic repair for type B aortic dissection. J Vasc Surg 2018; 68:14S-21S.e2. [PMID: 30064843 DOI: 10.1016/j.jvs.2018.06.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2017] [Accepted: 06/01/2018] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Retrograde type A dissection (RTAD) after thoracic endovascular aortic repair (TEVAR) has been a major drawback of endovascular treatment. To our knowledge, no studies have evaluated aortic injuries caused by stent grafts (SGs). Therefore, the aim of this study was to evaluate and to quantify the SG-aorta interaction and to analyze the risk factors for injury through computational simulation. METHODS The aortic geometry was extracted from an RTAD case. Five SG models were assembled based on Valiant and Talent (Medtronic Vascular, Santa Rosa, Calif) SGs, and modifications were made to the original SG design by adding and removing the connecting bar. TEVAR simulations were performed seven times for each SG model with 0% and 15% oversizing ratio (OSR), and the maximum aortic stress (MAS) was calculated and compared within the groups. RESULTS In all TEVAR models, MAS was seen at the proximal bare stent (PBS). The PBS in the Valiant and Talent SGs generated higher stress toward the aortic wall than other SG parts did. MAS was significantly higher for the 15% OSR (0.54 ± 0.07 MPa) than for the 0% OSR (1.32 ± 0.74 MPa) in 172.5-mm Valiant models. MAS was significantly higher in the Talent with connecting bar SG model (0.73 ± 0.24 MPa) than in the Talent without connecting bar SG model (0.51 ± 0.11 MPa). MAS was significantly higher in the Valiant with connecting bar SG model (0.82 ± 0.29 MPa) than in the Valiant without connecting bar SG model (0.54 ± 0.07 MPa). MAS was not significantly different in models with 172.5-mm and 140-mm Valiant SG implantations with 0% OSR (0.54 ± 0.07 MPa vs 0.60 ± 0.12 MPa) and 15% OSR (1.32 ± 0.74 MPa vs 1.12 ± 0.33 MPa). CONCLUSIONS The characteristic MAS distribution remained at the location where the apexes of the PBS interacted with the aortic wall at its greater curve. Both higher OSR and the presence of a connecting bar can significantly increase the MAS after SG implantation. Moreover, the chronic MAS at the PBS area may injure the aortic wall, causing RTAD.
Collapse
|
26
|
Kandail HS, Trivedi SD, Shaikh AC, Bajwa TK, O'Hair DP, Jahangir A, LaDisa JF. Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics. J Mech Behav Biomed Mater 2018; 86:131-142. [PMID: 29986288 DOI: 10.1016/j.jmbbm.2018.06.032] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Revised: 06/04/2018] [Accepted: 06/21/2018] [Indexed: 01/12/2023]
Abstract
CoreValve is widely used in transcatheter aortic valve replacement, but the impact of its deployment location on hemodynamics is unexplored despite a potential role in subsequent aortic and coronary artery pathologies. The objectives of this investigation were to perform fluid-structure interaction (FSI) simulations for a 29 mm CoreValve deployed in annular vs supra-annular locations, and characterize resulting hemodynamics including velocity and wall shear stress (WSS). Patient-specific geometry was reconstructed from computed tomography scans and CoreValve was deployed using a finite element approach. FSI simulations were then performed using a boundary conforming method and realistic boundary conditions. Results showed that CoreValve deployment location impacts hemodynamics in the ascending aorta and flow patterns in the coronary arteries. During peak-systole, annularly deployed CoreValve produced a jet-like flow structure impinging on the outer-curvature of the ascending aorta. Supra-annularly deployed CoreValve having a lateral tilt of 10° led to a more centered jet impinging further downstream. At mid-systole, valve leaflets of the annularly deployed CoreValve closed asymmetrically leading to disorganized flow patterns in the ascending aorta vs those from the supra-annular position. Supra-annularly deployed CoreValve also led to high-velocity para-valvular flow supplying the coronary arteries. CoreValve in the supra-annular position significantly (P < 0.05) elevated WSS within the first few diameters of both coronary arteries as compared to the annular position for many time points quantified. These results afforded by the advanced simulation methods may have important clinical implications given the role of aortic hemodynamics in dilation and the pro-atherogenic nature of WSS alterations in the coronary arteries.
Collapse
Affiliation(s)
- Harkamaljot S Kandail
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA.
| | - Setu D Trivedi
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Armaan C Shaikh
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Tanvir K Bajwa
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Daniel P O'Hair
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - Arshad Jahangir
- Aurora Cardiovascular Services, Aurora St. Luke's Medical Center, Milwaukee, WI, USA
| | - John F LaDisa
- Department of Biomedical Engineering, Marquette University and Medical College of Wisconsin, Milwaukee, WI, USA; Department of Medicine, Division of Cardiovascular Medicine, Medical College of Wisconsin, Milwaukee, WI, USA
| |
Collapse
|
27
|
Tricarico R, He Y, Laquian L, Scali ST, Tran-Son-Tay R, Beck AW, Berceli SA. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms. J Endovasc Ther 2017; 24:880-888. [PMID: 28914135 DOI: 10.1177/1526602817731096] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). METHODS A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. RESULTS Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area <14 mm2 (p=0.04), systolic pressure gradient >25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. CONCLUSION Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.
Collapse
Affiliation(s)
- Rosamaria Tricarico
- 1 Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA
| | - Yong He
- 2 North Florida/South Georgia Veterans Health System, University of Florida, Gainesville, FL, USA.,3 Department of Surgery, University of Florida, Gainesville, FL, USA
| | - Liza Laquian
- 3 Department of Surgery, University of Florida, Gainesville, FL, USA
| | - Salvatore T Scali
- 2 North Florida/South Georgia Veterans Health System, University of Florida, Gainesville, FL, USA.,3 Department of Surgery, University of Florida, Gainesville, FL, USA
| | - Roger Tran-Son-Tay
- 1 Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA.,4 Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, USA
| | - Adam W Beck
- 5 University of Alabama School of Medicine, Birmingham, AL, USA
| | - Scott A Berceli
- 1 Department of Biomedical Engineering, University of Florida, Gainesville, FL, USA.,2 North Florida/South Georgia Veterans Health System, University of Florida, Gainesville, FL, USA.,3 Department of Surgery, University of Florida, Gainesville, FL, USA
| |
Collapse
|
28
|
Singh P, Choudhury MI, Roy S, Prasad A. Computational study to investigate effect of tonometer geometry and patient-specific variability on radial artery tonometry. J Biomech 2017; 58:105-113. [PMID: 28528872 DOI: 10.1016/j.jbiomech.2017.04.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2016] [Revised: 03/25/2017] [Accepted: 04/24/2017] [Indexed: 10/19/2022]
Abstract
Tonometry-based devices are valuable method for vascular function assessment and for measurement of blood pressure. However current design and calibration methods rely on simple models, neglecting key geometrical features, and anthropometric and property variability among patients. Understanding impact of these influences on tonometer measurement is thus essential for improving outcomes of current devices, and for proposing improved design. Towards this goal, we present a realistic computational model for tissue-device interaction using complete wrist section with hyperelastic material and frictional contact. Three different tonometry geometries were considered including a new design, and patient-specific influences incorporated via anthropometric and age-dependent tissue stiffness variations. The results indicated that the new design showed stable surface contact stress with minimum influence of the parameters analyzed. The computational predictions were validated with experimental data from a prototype based on the new design. Finally, we showed that the underlying mechanics of vascular unloading in tonometry to be fundamentally different from that of oscillatory method. Due to directional loading in tonometry, pulse amplitude maxima was observed to occur at a significantly lower compression level (around 31%) than previously reported, which can impact blood pressure calibration approaches based on maximum pulse pressure recordings.
Collapse
Affiliation(s)
- Pranjal Singh
- Mechanical Engineering, Indian Institute of Technology Delhi, India
| | | | - Sitikantha Roy
- Applied Mechanics, Indian Institute of Technology Delhi, India
| | - Anamika Prasad
- Applied Mechanics, Indian Institute of Technology Delhi, India; Mechanical Engineering, South Dakota State University, United States.
| |
Collapse
|
29
|
An ovine in vivo framework for tracheobronchial stent analysis. Biomech Model Mechanobiol 2017; 16:1535-1553. [DOI: 10.1007/s10237-017-0904-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2016] [Accepted: 03/27/2017] [Indexed: 12/19/2022]
|
30
|
Nauta FJH, Lau KD, Arthurs CJ, Eagle KA, Williams DM, Trimarchi S, Patel HJ, Figueroa CA. Computational Fluid Dynamics and Aortic Thrombus Formation Following Thoracic Endovascular Aortic Repair. Ann Thorac Surg 2017; 103:1914-1921. [PMID: 28063468 DOI: 10.1016/j.athoracsur.2016.09.067] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Revised: 08/28/2016] [Accepted: 09/19/2016] [Indexed: 01/10/2023]
Abstract
BACKGROUND We present the possible utility of computational fluid dynamics in the assessment of thrombus formation and virtual surgical planning illustrated in a patient with aortic thrombus in a kinked ascending aortic graft following thoracic endovascular aortic repair. METHODS A patient-specific three-dimensional model was built from computed tomography. Additionally, we modeled 3 virtual aortic interventions to assess their effect on thrombosis potential: (1) open surgical repair, (2) conformable endografting, and (3) single-branched endografting. Flow waveforms were extracted from echocardiography and used for the simulations. We used the computational index termed platelet activation potential (PLAP) representing accumulated shear rates of fluid particles within a fluid domain to assess thrombosis potential. RESULTS The baseline model revealed high PLAP in the entire arch (119.8 ± 42.5), with significantly larger PLAP at the thrombus location (125.4 ± 41.2, p < 0.001). Surgical repair showed a 37% PLAP reduction at the thrombus location (78.6 ± 25.3, p < 0.001) and a 24% reduction in the arch (91.6 ± 28.9, p < 0.001). Single-branched endografting reduced PLAP in the thrombus region by 20% (99.7 ± 24.6, p < 0.001) and by 14% in the arch (103.8 ± 26.1, p < 0.001), whereas a more conformable endograft did not have a profound effect, resulting in a modest 4% PLAP increase (130.6 ± 43.7, p < 0.001) in the thrombus region relative to the baseline case. CONCLUSIONS Regions of high PLAP were associated with aortic thrombus. Aortic repair resolved pathologic flow patterns, reducing PLAP. Branched endografting also relieved complex flow patterns reducing PLAP. Computational fluid dynamics may assist in the prediction of aortic thrombus formation in hemodynamically complex cases and help guide repair strategies.
Collapse
Affiliation(s)
- Foeke J H Nauta
- Department of Surgery, University of Michigan, Ann Arbor, Michigan, USA; Thoracic Aortic Research Center, Vascular Surgery, Policlinico San Donato IRCCS, University of Milan, Italy
| | - Kevin D Lau
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Christopher J Arthurs
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom
| | - Kim A Eagle
- Department of Internal Medicine, University of Michigan, Ann Arbor, Michigan, USA
| | - David M Williams
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA
| | - Santi Trimarchi
- Thoracic Aortic Research Center, Vascular Surgery, Policlinico San Donato IRCCS, University of Milan, Italy
| | - Himanshu J Patel
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, Michigan, USA
| | - Carlos A Figueroa
- Department of Surgery, University of Michigan, Ann Arbor, Michigan, USA; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
| |
Collapse
|
31
|
Youssefi P, Sharma R, Figueroa CA, Jahangiri M. Functional assessment of thoracic aortic aneurysms - the future of risk prediction? Br Med Bull 2017; 121:61-71. [PMID: 27989994 PMCID: PMC5862296 DOI: 10.1093/bmb/ldw049] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 12/13/2016] [Indexed: 01/16/2023]
Abstract
INTRODUCTION Treatment guidelines for the thoracic aorta concentrate on size, yet acute aortic dissection or rupture can occur when aortic size is below intervention criteria. Functional imaging and computational techniques are a means of assessing haemodynamic parameters involved in aortic pathology. SOURCES OF DATA Original articles, reviews, international guidelines. AREAS OF AGREEMENT Computational fluid dynamics and 4D flow MRI allow non-invasive assessment of blood flow parameters and aortic wall biomechanics. AREAS OF CONTROVERSY Aortic valve morphology (particularly bicuspid aortic valve) is associated with aneurysm of the ascending aorta, although the exact mechanism of aneurysm formation is not yet established. GROWING POINTS Haemodynamic assessment of the thoracic aorta has highlighted parameters which are linked with both clinical outcome and protein changes in the aortic wall. Wall shear stress, flow displacement and helicity are elevated in patients with bicuspid aortic valve, particularly at locations of aneurysm formation. AREAS TIMELY FOR DEVELOPING RESEARCH With further validation, functional assessment of the aorta may help identify patients at risk of aortic complications, and introduce new haemodynamic indices into management guidelines.
Collapse
Affiliation(s)
- Pouya Youssefi
- Department of Cardiothoracic Surgery & Cardiology, St. George's Hospital, St. George's University of London, Blackshaw Road, London, SW17 0QT, United Kingdom.,Department of Biomedical Engineering, Rayne Institute, St. Thomas' Hospital, King's College London, London SE1 7EH, United Kingdom
| | - Rajan Sharma
- Department of Cardiothoracic Surgery & Cardiology, St. George's Hospital, St. George's University of London, Blackshaw Road, London, SW17 0QT, United Kingdom
| | - C Alberto Figueroa
- Department of Biomedical Engineering, Rayne Institute, St. Thomas' Hospital, King's College London, London SE1 7EH, United Kingdom.,Departments of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109 USA
| | - Marjan Jahangiri
- Department of Cardiothoracic Surgery & Cardiology, St. George's Hospital, St. George's University of London, Blackshaw Road, London, SW17 0QT, United Kingdom
| |
Collapse
|
32
|
|
33
|
Roy D, Lerouge S, Inaekyan K, Kauffmann C, Mongrain R, Soulez G. Experimental validation of more realistic computer models for stent-graft repair of abdominal aortic aneurysms, including pre-load assessment. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2016; 32:e02769. [PMID: 26748474 DOI: 10.1002/cnm.2769] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 12/30/2015] [Accepted: 01/04/2016] [Indexed: 06/05/2023]
Abstract
Although the endovascular repair of abdominal aortic aneurysms is a less invasive alternative than classic open surgery, complications such as endoleak and kinking still need to be addressed. Numerical simulation of endovascular repair is becoming a valuable tool in stent-graft (SG) optimization, patient selection and surgical planning. The experimental and numerical forces required to produce SG deformations were compared in a range of in vivo conditions in the present study. The deformation modes investigated were: bending as well as axial, transversal and radial compressions. In particular, an original method was developed to efficiently account for radial pre-load because of the pre-compression of stents to match the graft dimensions during manufacturing. This is important in order to compute the radial force exerted on the vessel after deployment more accurately. Variations of displacement between the experimental and numerical results ranged from 1.39% for simple leg bending to 5.93% for three-point body bending. Finally, radial pre-load was modeled by increasing Young's modulus of each stent. On average, it was found that Young's modulus had to be augmented by a factor of 2. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- David Roy
- Centre de Recherche, Centre Hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada, H2X 0A9
- Biomedical Engineering Institute, Université de Montréal, Montréal, Québec, Canada, H3T 1J4
| | - Sophie Lerouge
- Centre de Recherche, Centre Hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada, H2X 0A9
- Department of Mechanical Engineering, École de Technologie Supérieure, Montréal, Québec, Canada, H3C 1K3
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada, H3C 3J7
| | - Karina Inaekyan
- Department of Mechanical Engineering, École de Technologie Supérieure, Montréal, Québec, Canada, H3C 1K3
| | - Claude Kauffmann
- Centre de Recherche, Centre Hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada, H2X 0A9
| | - Rosaire Mongrain
- Department of Mechanical Engineering, McGill University, Montréal, Québec, Canada, H3A 0C3
| | - Gilles Soulez
- Centre de Recherche, Centre Hospitalier de l'Université de Montréal (CRCHUM), Montréal, Québec, Canada, H2X 0A9
- Biomedical Engineering Institute, Université de Montréal, Montréal, Québec, Canada, H3T 1J4
- Department of Radiology, Radio-Oncology and Nuclear Medicine, Université de Montréal, Montréal, Québec, Canada, H3C 3J7
| |
Collapse
|
34
|
McGrath D, O’Brien B, Bruzzi M, Kelly N, Clauser J, Steinseifer U, McHugh P. Evaluation of cover effects on bare stent mechanical response. J Mech Behav Biomed Mater 2016; 61:567-580. [DOI: 10.1016/j.jmbbm.2016.04.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Revised: 03/25/2016] [Accepted: 04/15/2016] [Indexed: 11/28/2022]
|
35
|
Perrin D, Badel P, Orgeas L, Geindreau C, du Roscoat SR, Albertini JN, Avril S. Patient-specific simulation of endovascular repair surgery with tortuous aneurysms requiring flexible stent-grafts. J Mech Behav Biomed Mater 2016; 63:86-99. [PMID: 27344232 DOI: 10.1016/j.jmbbm.2016.06.013] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Revised: 05/10/2016] [Accepted: 06/11/2016] [Indexed: 10/21/2022]
Abstract
The rate of post-operative complications is the main drawback of endovascular repair, a technique used to treat abdominal aortic aneurysms. Complex anatomies, featuring short aortic necks and high vessel tortuosity for instance, have been proved likely prone to these complications. In this context, practitioners could benefit, at the preoperative planning stage, from a tool able to predict the post-operative position of the stent-graft, to validate their stent-graft sizing and anticipate potential complications. In consequence, the aim of this work is to prove the ability of a numerical simulation methodology to reproduce accurately the shapes of stent-grafts, with a challenging design, deployed inside tortuous aortic aneurysms. Stent-graft module samples were scanned by X-ray microtomography and subjected to mechanical tests to generate finite-element models. Two EVAR clinical cases were numerically reproduced by simulating stent-graft models deployment inside the tortuous arterial model generated from patient pre-operative scan. In the same manner, an in vitro stent-graft deployment in a rigid polymer phantom, generated by extracting the arterial geometry from the preoperative scan of a patient, was simulated to assess the influence of biomechanical environment unknowns in the in vivo case. Results were validated by comparing stent positions on simulations and post-operative scans. In all cases, simulation predicted stents deployed locations and shapes with an accuracy of a few millimetres. The good results obtained in the in vitro case validated the ability of the methodology to simulate stent-graft deployment in very tortuous arteries and led to think proper modelling of biomechanical environment could reduce the few local discrepancies found in the in vivo case. In conclusion, this study proved that our methodology can achieve accurate simulation of stent-graft deployed shape even in tortuous patient specific aortic aneurysms and may be potentially helpful to help practitioners plan their intervention.
Collapse
Affiliation(s)
- David Perrin
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, SAINBIOSE, F-42023 Saint-Etienne, France; CNRS, 3SR Lab, F-38000 Grenoble, France; Univ. Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France; INSERM U1059, SAINBIOSE, F-42023 Saint-Etienne, France; Université de Lyon, F-69000 Lyon, France
| | - Pierre Badel
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, SAINBIOSE, F-42023 Saint-Etienne, France; INSERM U1059, SAINBIOSE, F-42023 Saint-Etienne, France; Université de Lyon, F-69000 Lyon, France
| | - Laurent Orgeas
- CNRS, 3SR Lab, F-38000 Grenoble, France; Univ. Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Christian Geindreau
- CNRS, 3SR Lab, F-38000 Grenoble, France; Univ. Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | | | - Jean-Noël Albertini
- INSERM U1059, SAINBIOSE, F-42023 Saint-Etienne, France; Université de Lyon, F-69000 Lyon, France; CHU Hôpital Nord Saint-Etienne, Department of CardioVascular Surgery, Saint-Etienne F-42055, France
| | - Stéphane Avril
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, SAINBIOSE, F-42023 Saint-Etienne, France; INSERM U1059, SAINBIOSE, F-42023 Saint-Etienne, France; Université de Lyon, F-69000 Lyon, France.
| |
Collapse
|
36
|
Kandail HS, Hamady M, Xu XY. Hemodynamic Functions of Fenestrated Stent Graft under Resting, Hypertension, and Exercise Conditions. Front Surg 2016; 3:35. [PMID: 27379242 PMCID: PMC4906822 DOI: 10.3389/fsurg.2016.00035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2016] [Accepted: 05/30/2016] [Indexed: 11/29/2022] Open
Abstract
The aim of this study was to assess the hemodynamic performance of a patient-specific fenestrated stent graft (FSG) under different physiological conditions, including normal resting, hypertension, and hypertension with moderate lower limb exercise. A patient-specific FSG model was constructed from computed tomography images and was discretized into a fine unstructured mesh comprising tetrahedral and prism elements. Blood flow was simulated using Navier-Stokes equations, and physiologically realistic boundary conditions were utilized to yield clinically relevant results. For a given cycle-averaged inflow of 2.08 L/min at normal resting and hypertension conditions, approximately 25% of flow was channeled into each renal artery. When hypertension was combined with exercise, the cycle-averaged inflow increased to 6.39 L/min but only 6.29% of this was channeled into each renal artery, which led to a 438.46% increase in the iliac flow. For all the simulated scenarios and throughout the cardiac cycle, the instantaneous flow streamlines in the FSG were well organized without any notable flow recirculation. This well-organized flow led to low values of endothelial cell activation potential, which is a hemodynamic metric used to identify regions at risk of thrombosis. The displacement forces acting on the FSG varied with the physiological conditions, and the cycle-averaged displacement force at normal rest, hypertension, and hypertension with exercise was 6.46, 8.77, and 8.99 N, respectively. The numerical results from this study suggest that the analyzed FSG can maintain sufficient blood perfusion to the end organs at all the simulated conditions. Even though the FSG was found to have a low risk of thrombosis at rest and hypertension, this risk can be reduced even further with moderate lower limb exercise.
Collapse
Affiliation(s)
| | - Mohamad Hamady
- Department of Interventional Radiology, St Mary’s Hospital, Imperial College Healthcare NHS Trust, London, UK
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| |
Collapse
|
37
|
Nauta FJH, Conti M, Kamman AV, van Bogerijen GHW, Tolenaar JL, Auricchio F, Figueroa CA, van Herwaarden JA, Moll FL, Trimarchi S. Biomechanical Changes After Thoracic Endovascular Aortic Repair in Type B Dissection. J Endovasc Ther 2015; 22:918-33. [DOI: 10.1177/1526602815608848] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Thoracic endovascular aortic repair (TEVAR) has evolved into an established treatment option for type B aortic dissection (TBAD) since it was first introduced 2 decades ago. Morbidity and mortality have decreased due to the minimally invasive character of TEVAR, with adequate stabilization of the dissection, restoration of true lumen perfusion, and subsequent positive aortic remodeling. However, several studies have reported severe setbacks of this technique. Indeed, little is known about the biomechanical behavior of implanted thoracic stent-grafts and the impact on the vascular system. This study sought to systematically review the performance and behavior of implanted thoracic stent-grafts and related biomechanical aortic changes in TBAD patients in order to update current knowledge and future perspectives.
Collapse
Affiliation(s)
- Foeke J. H. Nauta
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy
- Departments of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- Department of Vascular Surgery, University Medical Center Utrecht, the Netherlands
| | - Michele Conti
- Department of Civil Engineering and Architecture, University of Pavia, Italy
| | - Arnoud V. Kamman
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy
- Departments of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
- Department of Vascular Surgery, University Medical Center Utrecht, the Netherlands
| | | | - Jip L. Tolenaar
- Department of General Surgery, St. Antonius Hospital, Nieuwegein, the Netherlands
| | | | - C. Alberto Figueroa
- Departments of Surgery and Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
| | | | - Frans L. Moll
- Department of Vascular Surgery, University Medical Center Utrecht, the Netherlands
| | - Santi Trimarchi
- Thoracic Aortic Research Center, Policlinico San Donato IRCCS, University of Milan, Italy
| |
Collapse
|
38
|
Boufi M, Guivier-Curien C, Deplano V, Boiron O, Loundou A, Dona B, Hartung O, Alimi Y. Risk Factor Analysis of Bird Beak Occurrence after Thoracic Endovascular Aortic Repair. Eur J Vasc Endovasc Surg 2015; 50:37-43. [DOI: 10.1016/j.ejvs.2015.04.018] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Accepted: 04/12/2015] [Indexed: 11/17/2022]
|
39
|
Perrin D, Badel P, Orgéas L, Geindreau C, Dumenil A, Albertini JN, Avril S. Patient-specific numerical simulation of stent-graft deployment: Validation on three clinical cases. J Biomech 2015; 48:1868-75. [PMID: 25979382 DOI: 10.1016/j.jbiomech.2015.04.031] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Revised: 02/25/2015] [Accepted: 04/23/2015] [Indexed: 11/17/2022]
Abstract
Endovascular repair of abdominal aortic aneurysms faces some adverse outcomes, such as kinks or endoleaks related to incomplete stent apposition, which are difficult to predict and which restrain its use although it is less invasive than open surgery. Finite element simulations could help to predict and anticipate possible complications biomechanically induced, thus enhancing practitioners' stent-graft sizing and surgery planning, and giving indications on patient eligibility to endovascular repair. The purpose of this work is therefore to develop a new numerical methodology to predict stent-graft final deployed shapes after surgery. The simulation process was applied on three clinical cases, using preoperative scans to generate patient-specific vessel models. The marketed devices deployed during the surgery, consisting of a main body and one or more iliac limbs or extensions, were modeled and their deployment inside the corresponding patient aneurysm was simulated. The numerical results were compared to the actual deployed geometry of the stent-grafts after surgery that was extracted from postoperative scans. We observed relevant matching between simulated and actual deployed stent-graft geometries, especially for proximal and distal stents outside the aneurysm sac which are particularly important for practitioners. Stent locations along the vessel centerlines in the three simulations were always within a few millimeters to actual stents locations. This good agreement between numerical results and clinical cases makes finite element simulation very promising for preoperative planning of endovascular repair.
Collapse
Affiliation(s)
- David Perrin
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS: UMR5307, LGF, F-42023 Saint-Etienne, France; CNRS, 3SR Lab, F-38000 Grenoble, France; Université Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Pierre Badel
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS: UMR5307, LGF, F-42023 Saint-Etienne, France
| | - Laurent Orgéas
- CNRS, 3SR Lab, F-38000 Grenoble, France; Université Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Christian Geindreau
- CNRS, 3SR Lab, F-38000 Grenoble, France; Université Grenoble Alpes, 3SR Lab, F-38000 Grenoble, France
| | - Aurélien Dumenil
- INSERM, U1099, F-35000 Rennes, France; Université de Rennes 1, LTSI, F-35000 Rennes, France; Therenva, F-35000 Rennes, France
| | - Jean-Noël Albertini
- CHU Hôpital Nord Saint-Etienne, Department of CardioVascular Surgery, Saint-Etienne F-42055, France; Université Jean Monnet, GRT EA 3065, Saint-Etienne F-42023, France
| | - Stéphane Avril
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS: UMR5307, LGF, F-42023 Saint-Etienne, France.
| |
Collapse
|
40
|
Perrin D, Demanget N, Badel P, Avril S, Orgéas L, Geindreau C, Albertini JN. Deployment of stent grafts in curved aneurysmal arteries: toward a predictive numerical tool. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2015; 31:e02698. [PMID: 25399927 DOI: 10.1002/cnm.2698] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 10/16/2014] [Accepted: 11/10/2014] [Indexed: 06/04/2023]
Abstract
The mechanical behavior of aortic stent grafts plays an important role in the success of endovascular surgery for aneurysms. In this study, finite element analysis was carried out to simulate the expansion of five marketed stent graft iliac limbs and to evaluate quantitatively their mechanical performances. The deployment was modeled in a simplified manner according to the following steps: (i) stent graft crimping and insertion in the delivery sheath, (ii) removal of the sheath and stent graft deployment in the aneurysm, and (iii) application of arterial pressure. In the most curved aneurysm and for some devices, a decrease of stent graft cross-sectional area up to 57% was found at the location of some kinks. Apposition defects onto the arterial wall were also clearly evidenced and quantified. Aneurysm inner curve presented significantly more apposition defects than outer curve. The feasibility of finite element analysis to simulate deployment of marketed stent grafts in curved aneurysm models was demonstrated. The study of the influence of aneurysm tortuosity on stent graft mechanical behavior shows that increasing vessel curvature leads to stent graft kinks and inadequate apposition against the arterial wall. Such simulation approach opens a very promising way toward surgical planning tools able to predict intra and/or post-operative short-term stent graft complications.
Collapse
Affiliation(s)
- David Perrin
- Ecole Nationale Supérieure des Mines de Saint-Etienne, CIS-EMSE, CNRS:UMR5307, LGF, F-42023, Saint Etienne, France; CNRS, 3SR Lab, F-38000, Grenoble, France; Univ. Grenoble Alpes, 3SR Lab, F-38000, Grenoble, France
| | | | | | | | | | | | | |
Collapse
|
41
|
Altnji HE, Bou-Saïd B, Walter-Le Berre H. Morphological and stent design risk factors to prevent migration phenomena for a thoracic aneurysm: A numerical analysis. Med Eng Phys 2015; 37:23-33. [DOI: 10.1016/j.medengphy.2014.09.017] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 08/21/2014] [Accepted: 09/30/2014] [Indexed: 10/24/2022]
|
42
|
Appoo JJ, Herget EJ, Pozeg ZI, Ferris MC, Wong JK, Gregory AJ, Gupta AK, Merchant N, Kent WDT. Midterm results of endovascular stent grafts in the proximal aortic arch (zone 0): an imaging perspective. Can J Cardiol 2014; 31:731-7. [PMID: 25882336 DOI: 10.1016/j.cjca.2014.12.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2014] [Revised: 12/12/2014] [Accepted: 12/12/2014] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Endovascular options to repair the arch and ascending aorta are rapidly evolving. Little is known about the durability of endovascular devices deployed at this location. This report describes a single-centre experience with the novel application of thoracic endovascular aortic repair (TEVAR) by examining clinical and radiological outcomes. METHODS A retrospective review was performed for a cohort of patients undergoing TEVAR of the arch or ascending aorta, or both, at a single centre from November 2008-July 2012. RESULTS Sixteen patients were included in the study, with mean imaging follow-up of 38 months (range, 15-72 months). Two complications at the proximal landing zone in the ascending aorta were identified: 1 endoleak and 1 infolding identified at 3 and 24 months postoperatively, respectively. Clinically, both these complications were attributed to the bird-beak configuration at the proximal landing zone site. At up to 72 months of follow-up, there were no cases of retrograde dissection of the native sinus of Valsalva. There were no cases of stent graft migration, graft fracture, open surgical reintervention for aortic pathologic conditions, or late mortality. CONCLUSIONS Early outcomes suggest that the current generation of thoracic aortic endografts can be placed in the complex anatomy of the ascending aorta and aortic arch without a high incidence of early graft fracture or migration. Future endeavors will need to focus on techniques to achieve optimal apposition with the curves of the ascending aorta. These findings are important as indications for endovascular aortic therapies expand to address proximal aortic pathologic conditions.
Collapse
Affiliation(s)
- Jehangir J Appoo
- Division of Cardiac Surgery, Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada.
| | - Eric J Herget
- Department of Diagnostic Imaging, University of Calgary, Calgary, Alberta, Canada
| | - Zlatko I Pozeg
- Division of Cardiac Surgery, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Mollie C Ferris
- Department of Diagnostic Imaging, University of Calgary, Calgary, Alberta, Canada
| | - Jason K Wong
- Department of Diagnostic Imaging, University of Calgary, Calgary, Alberta, Canada
| | - Alex J Gregory
- Department of Anaesthesia, University of Calgary, Calgary, Alberta, Canada
| | - Arjun K Gupta
- Division of Cardiac Surgery, Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada
| | - Naeem Merchant
- Department of Diagnostic Imaging, University of Calgary, Calgary, Alberta, Canada
| | - William D T Kent
- Division of Cardiac Surgery, Libin Cardiovascular Institute, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
43
|
Pant S, Fabrèges B, Gerbeau JF, Vignon-Clementel IE. A methodological paradigm for patient-specific multi-scale CFD simulations: from clinical measurements to parameter estimates for individual analysis. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2014; 30:1614-1648. [PMID: 25345820 DOI: 10.1002/cnm.2692] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Revised: 09/19/2014] [Accepted: 10/19/2014] [Indexed: 06/04/2023]
Abstract
A new framework for estimation of lumped (for instance, Windkessel) model parameters from uncertain clinical measurements is presented. The ultimate aim is to perform patient-specific haemodynamic analysis. This framework is based on sensitivity analysis tools and the sequential estimation approach of the unscented Kalman filter. Sensitivity analysis and parameter estimation are performed in lumped parameter models, which act as reduced order surrogates of the 3D domain for haemodynamic analysis. While the goal of sensitivity analysis is to assess potential identifiability problems, the unscented Kalman filter estimation leads to parameter estimates based on clinical measurements and modelling assumptions. An application of such analysis and parameter estimation methodology is demonstrated for synthetic and real data. Equality constraints on various physiological parameters are enforced. Since the accuracy of the Windkessel parameter estimates depends on the lumped parameter representativeness, the latter is iteratively improved by running few 3D simulations while simultaneously improving the former. Such a method is applied on a patient-specific aortic coarctation case. Less than 3% and 9% errors between the clinically measured quantities and 3D simulation results for rest and stress are obtained, respectively. Knowledge on how these Windkessel parameters change from rest to stress can thus be learned by such an approach. Lastly, it is demonstrated that the proposed approach is capable of dealing with a wide variety of measurements and cases where the pressure and flow clinical measurements are not taken simultaneously.
Collapse
Affiliation(s)
- S Pant
- INRIA Paris-Rocquencourt, 78153 Le Chesnay, France; UPMC Université Paris 6, Laboratoire Jacques-Louis Lions, 75005 Paris, France
| | | | | | | |
Collapse
|
44
|
De Bock S, Iannaccone F, De Beule M, Vermassen F, Segers P, Verhegghe B. What if you stretch the IFU? A mechanical insight into stent graft Instructions For Use in angulated proximal aneurysm necks. Med Eng Phys 2014; 36:1567-76. [DOI: 10.1016/j.medengphy.2014.08.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2013] [Revised: 07/23/2014] [Accepted: 08/10/2014] [Indexed: 10/24/2022]
|
45
|
Ragkousis GE, Curzen N, Bressloff NW. Simulation of longitudinal stent deformation in a patient-specific coronary artery. Med Eng Phys 2014; 36:467-76. [DOI: 10.1016/j.medengphy.2014.02.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 01/14/2014] [Accepted: 02/07/2014] [Indexed: 01/27/2023]
|
46
|
Xiao N, Alastruey J, Figueroa CA. A systematic comparison between 1-D and 3-D hemodynamics in compliant arterial models. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2014; 30:204-31. [PMID: 24115509 PMCID: PMC4337249 DOI: 10.1002/cnm.2598] [Citation(s) in RCA: 173] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2012] [Revised: 08/14/2013] [Accepted: 08/15/2013] [Indexed: 05/05/2023]
Abstract
We present a systematic comparison of computational hemodynamics in arteries between a one-dimensional (1-D) and a three-dimensional (3-D) formulation with deformable vessel walls. The simulations were performed using a series of idealized compliant arterial models representing the common carotid artery, thoracic aorta, aortic bifurcation, and full aorta from the arch to the iliac bifurcation. The formulations share identical inflow and outflow boundary conditions and have compatible material laws. We also present an iterative algorithm to select the parameters for the outflow boundary conditions by using the 1-D theory to achieve a desired systolic and diastolic pressure at a particular vessel. This 1-D/3-D framework can be used to efficiently determine material and boundary condition parameters for 3-D subject-specific arterial models with deformable vessel walls. Finally, we explore the impact of different anatomical features and hemodynamic conditions on the numerical predictions. The results show good agreement between the two formulations, especially during the diastolic phase of the cycle.
Collapse
Affiliation(s)
- Nan Xiao
- Department of Biomedical Engineering, King’s College London, UK
- Department of Bioengineering, Stanford University, CA, USA
| | - Jordi Alastruey
- Department of Biomedical Engineering, King’s College London, UK
| | | |
Collapse
|
47
|
Allard L, Soulez G, Chayer B, Qin Z, Roy D, Cloutier G. A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus. Med Phys 2014; 40:063701. [PMID: 23718616 DOI: 10.1118/1.4803497] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. METHODS A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. RESULTS MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in concordance with the literature for vascular and abdominal tissues. CONCLUSIONS The mimicked abdominal tissues, AAA wall, and surrounding thrombus were developed to match imaging features of in vivo MR, CT, and ultrasound examinations. This phantom should be of value for image calibration, segmentation, and testing of endovascular devices for AAA endovascular repair.
Collapse
Affiliation(s)
- Louise Allard
- Laboratory of Biorheology and Medical Ultrasonics, Research Center, University of Montreal Hospital (CRCHUM), Québec H2L 2W5, Canada
| | | | | | | | | | | |
Collapse
|