1
|
Rolf-Pissarczyk M, Schussnig R, Fries TP, Fleischmann D, Elefteriades JA, Humphrey JD, Holzapfel GA. Mechanisms of aortic dissection: From pathological changes to experimental and in silico models. PROGRESS IN MATERIALS SCIENCE 2025; 150:101363. [PMID: 39830801 PMCID: PMC11737592 DOI: 10.1016/j.pmatsci.2024.101363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
Abstract
Aortic dissection continues to be responsible for significant morbidity and mortality, although recent advances in medical data assimilation and in experimental and in silico models have improved our understanding of the initiation and progression of the accumulation of blood within the aortic wall. Hence, there remains a pressing necessity for innovative and enhanced models to more accurately characterize the associated pathological changes. Early on, experimental models were employed to uncover mechanisms in aortic dissection, such as hemodynamic changes and alterations in wall microstructure, and to assess the efficacy of medical implants. While experimental models were once the only option available, more recently they are also being used to validate in silico models. Based on an improved understanding of the deteriorated microstructure of the aortic wall, numerous multiscale material models have been proposed in recent decades to study the state of stress in dissected aortas, including the changes associated with damage and failure. Furthermore, when integrated with accessible patient-derived medical data, in silico models prove to be an invaluable tool for identifying correlations between hemodynamics, wall stresses, or thrombus formation in the deteriorated aortic wall. They are also advantageous for model-guided design of medical implants with the aim of evaluating the deployment and migration of implants in patients. Nonetheless, the utility of in silico models depends largely on patient-derived medical data, such as chosen boundary conditions or tissue properties. In this review article, our objective is to provide a thorough summary of medical data elucidating the pathological alterations associated with this disease. Concurrently, we aim to assess experimental models, as well as multiscale material and patient data-informed in silico models, that investigate various aspects of aortic dissection. In conclusion, we present a discourse on future perspectives, encompassing aspects of disease modeling, numerical challenges, and clinical applications, with a particular focus on aortic dissection. The aspiration is to inspire future studies, deepen our comprehension of the disease, and ultimately shape clinical care and treatment decisions.
Collapse
Affiliation(s)
| | - Richard Schussnig
- High-Performance Scientific Computing, University of Augsburg, Germany
- Institute of Structural Analysis, Graz University of Technology, Austria
| | - Thomas-Peter Fries
- Institute of Structural Analysis, Graz University of Technology, Austria
| | - Dominik Fleischmann
- 3D and Quantitative Imaging Laboratory, Department of Radiology, Stanford University, USA
| | | | - Jay D. Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, USA
| | - Gerhard A. Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway
| |
Collapse
|
2
|
Gu H, Lee S, Kim S, Jang HL, Choi DW, Kim KS, Shin YR, Cheung DY, Lee BI, Kim JI, Lee HH. Development of colonic stent simulator using three-dimensional printing technique: a simulator development study in Korea. Clin Endosc 2024; 57:790-797. [PMID: 39308325 PMCID: PMC11637659 DOI: 10.5946/ce.2024.110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 05/31/2024] [Accepted: 06/01/2024] [Indexed: 12/14/2024] Open
Abstract
BACKGROUND/AIMS Colonic stenting plays a vital role in the management of acute malignant colonic obstruction. The increasing use of self-expandable metal stents (SEMS) and the diverse challenges posed by colonic obstruction at various locations underscore the importance of effective training for colonic stent placement. METHODS All the components of the simulator were manufactured using silicone molding techniques in conjunction with three-dimensional (3D) printing. 3D images sourced from computed tomography scans and colonoscopy images were converted into a stereolithography format. Acrylonitrile butadiene styrene copolymers have been used in fused deposition modeling to produce moldings. RESULTS The simulator replicated the large intestine from the rectum to the cecum, mimicking the texture and shape of the human colon. It enables training for colonoscopy insertion, cecum intubation, loop reduction, and stenting within stenotic areas. Interchangeable stenotic modules for four sites (rectum, sigmoid colon, descending colon, and ascending colon) were easily assembled for training. These modules integrate tumor contours and blood vessel structures with a translucent center, allowing real-time visualization during stenting. Successful and repeatable demonstrations of stent insertion and expansion using the reusable SEMS were consistently achieved. CONCLUSIONS This innovative simulator offers a secure colonic stenting practice across various locations, potentially enhancing clinical outcomes by improving operator proficiency during actual procedures.
Collapse
Affiliation(s)
- Hyundam Gu
- Division of Gastroenterology, Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Suyoung Lee
- Division of Gastroenterology, Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | | | | | | | - Kyu Seok Kim
- Interventional Research Center, M. I. Tech Co., Ltd., Pyeongtaek, Korea
| | - Yu Ri Shin
- Department of Radiology, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Dae Young Cheung
- Division of Gastroenterology, Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Bo-In Lee
- Division of Gastroenterology, Department of Internal Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Jin Il Kim
- Division of Gastroenterology, Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Han Hee Lee
- Division of Gastroenterology, Department of Internal Medicine, Yeouido St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| |
Collapse
|
3
|
Carbonaro D, Villa E, Gallo D, Morbiducci U, Audenino AL, Chiastra C. Designing the mechanical behavior of NiTi self-expandable vascular stents by tuning the heat treatment parameters. J Mech Behav Biomed Mater 2024; 158:106653. [PMID: 39074439 DOI: 10.1016/j.jmbbm.2024.106653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 06/14/2024] [Accepted: 07/06/2024] [Indexed: 07/31/2024]
Abstract
The remarkable mechanical properties of nickel-titanium (NiTi) shape memory alloy, particularly its super-elasticity, establish it as the material of choice for fabricating self-expanding vascular stents, including the metallic backbone of peripheral stents and the metallic frame of stent-grafts. The super-elastic nature of NiTi substantially influences the mechanical performance of vascular stents, thereby affecting their clinical effectiveness and safety. This property shows marked sensitivity to the primary parameters of the heat treatment process used in device fabrication, specifically temperature and processing time. In this context, this study integrates experimental and computational analyses to explore the potential of designing the mechanical characteristics of NiTi vascular stents by adjusting heat treatment parameters. To reach this aim, differently heat-treated NiTi wire samples were experimentally characterized using calorimetric and uniaxial tensile testing. Subsequently, the mechanical response of a stent-graft model featuring a metallic frame made of NiTi wire was assessed in terms of radial forces generated at various implantation diameters through finite element analysis. The stent-graft served as an illustrative case of NiTi vascular stent to investigate the impact of the heat treatment parameters on its mechanical response. From the study a strong linear relationship emerged between NiTi super-elastic parameters (i.e., austenite finish temperature, martensite elastic modulus, upper plateau stress, lower plateau stress and transformation strain) and heat treatment parameters (R2 > 0.79, p-value < 0.001) for the adopted ranges of temperature and processing time. Additionally, a strong linear relationship was observed between: (i) the radial force generated by the stent-graft during expansion and the heat treatment parameters (R2 > 0.82, p-value < 0.001); (ii) the radial force generated by the stent-graft during expansion and the lower plateau stress of NiTi (R2 > 0.93, p-value < 0.001). In conclusion, the findings of this study suggest that designing and optimizing the mechanical properties of NiTi vascular stents by finely tuning temperature and processing time of the heat treatment process is feasible.
Collapse
Affiliation(s)
- Dario Carbonaro
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Elena Villa
- National Research Council, Institute of Condensed Matter Chemistry and Technologies for Energy (CNR-ICMATE), Lecco, Italy
| | - Diego Gallo
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Umberto Morbiducci
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Alberto Luigi Audenino
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
| | - Claudio Chiastra
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
4
|
Wang K, Armour CH, Guo B, Dong Z, Xu XY. A new method for scaling inlet flow waveform in hemodynamic analysis of aortic dissection. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3855. [PMID: 39051141 DOI: 10.1002/cnm.3855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Revised: 06/14/2024] [Accepted: 07/12/2024] [Indexed: 07/27/2024]
Abstract
Computational fluid dynamics (CFD) simulations have shown great potentials in cardiovascular disease diagnosis and postoperative assessment. Patient-specific and well-tuned boundary conditions are key to obtaining accurate and reliable hemodynamic results. However, CFD simulations are usually performed under non-patient-specific flow conditions due to the absence of in vivo flow and pressure measurements. This study proposes a new method to overcome this challenge by tuning inlet boundary conditions using data extracted from electrocardiogram (ECG). Five patient-specific geometric models of type B aortic dissection were reconstructed from computed tomography (CT) images. Other available data included stoke volume (SV), ECG, and 4D-flow magnetic resonance imaging (MRI). ECG waveforms were processed to extract patient-specific systole to diastole ratio (SDR). Inlet boundary conditions were defined based on a generic aortic flow waveform tuned using (1) SV only, and (2) with ECG and SV (ECG + SV). 4D-flow MRI derived inlet boundary conditions were also used in patient-specific simulations to provide the gold standard for comparison and validation. Simulations using inlet flow waveform tuned with ECG + SV not only successfully reproduced flow distributions in the descending aorta but also provided accurate prediction of time-averaged wall shear stress (TAWSS) in the primary entry tear (PET) and abdominal regions, as well as maximum pressure difference, ∆Pmax, from the aortic root to the distal false lumen. Compared with simulations with inlet waveform tuned with SV alone, using ECG + SV in the tuning method significantly reduced the error in false lumen ejection fraction at the PET (from 149.1% to 6.2%), reduced errors in TAWSS at the PET (from 54.1% to 5.7%) and in the abdominal region (from 61.3% to 11.1%), and improved ∆Pmax prediction (from 283.1% to 18.8%) However, neither of these inlet waveforms could be used for accurate prediction of TAWSS in the ascending aorta. This study demonstrates the importance of SDR in tailoring inlet flow waveforms for patient-specific hemodynamic simulations. A well-tuned flow waveform is essential for ensuring that the simulation results are patient-specific, thereby enhancing the confidence and fidelity of computational tools in future clinical applications.
Collapse
Affiliation(s)
- Kaihong Wang
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Chlöe H Armour
- Department of Chemical Engineering, Imperial College London, London, UK
- National Heart and Lung Institute, Imperial College London, London, UK
| | - Baolei Guo
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| |
Collapse
|
5
|
Donik Ž, Li W, Nnate B, Pugar JA, Nguyen N, Milner R, Cerda E, Pocivavsek L, Kramberger J. A computational study of artery curvature and endograft oversize influence on seal zone behavior in endovascular aortic repair. Comput Biol Med 2024; 178:108745. [PMID: 38901185 PMCID: PMC11317088 DOI: 10.1016/j.compbiomed.2024.108745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 05/18/2024] [Accepted: 06/08/2024] [Indexed: 06/22/2024]
Abstract
Thoracic endovascular aortic repair (TEVAR) is a minimally invasive procedure involving the placement of an endograft inside the dissection or an aneurysm to direct blood flow and prevent rupture. A significant challenge in endovascular surgery is the geometrical mismatch between the endograft and the artery, which can lead to endoleak formation, a condition where blood leaks between the endograft and the vessel wall. This study uses computational modeling to investigate the effects of artery curvature and endograft oversizing, the selection of an endograft with a larger diameter than the artery, on endoleak creation. Finite element analysis is employed to simulate the deployment of endografts in arteries with varying curvature and diameter. Numerical simulations are conducted to assess the seal zone and to quantify the potential endoleak volume as a function of curvature and oversizing. A theoretical framework is developed to explain the mechanisms of endoleak formation along with proof-of-concept experiments. Two main mechanisms of endoleak creation are identified: local buckling due to diameter mismatch and global buckling due to centerline curvature mismatch. Local buckling, characterized by excess graft material buckling and wrinkle formation, increases with higher levels of oversizing, leading to a larger potential endoleak volume. Global buckling, where the endograft bends or deforms to conform to the centerline curvature of the artery, is observed to require a certain degree of oversizing to bridge the curvature mismatch. This study highlights the importance of considering both curvature and diameter mismatch in the design and clinical use of endografts. Understanding the mechanisms of endoleak formation can provide valuable insights for optimizing endograft design and surgical planning, leading to improved clinical outcomes in endovascular aortic procedures.
Collapse
Affiliation(s)
- Žiga Donik
- Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia.
| | - Willa Li
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, The University of Chicago, 5841 S Maryland Ave, MC 5028, Chicago, IL 60637, USA
| | - Blessing Nnate
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, The University of Chicago, 5841 S Maryland Ave, MC 5028, Chicago, IL 60637, USA
| | - Joseph A Pugar
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, The University of Chicago, 5841 S Maryland Ave, MC 5028, Chicago, IL 60637, USA
| | - Nhung Nguyen
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, The University of Chicago, 5841 S Maryland Ave, MC 5028, Chicago, IL 60637, USA
| | - Ross Milner
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, The University of Chicago, 5841 S Maryland Ave, MC 5028, Chicago, IL 60637, USA
| | - Enrique Cerda
- Departamento de Física, Facultad de Ciencia, Universidad de Santiago de Chile (USACH), Santiago Chile
| | - Luka Pocivavsek
- Section of Vascular Surgery and Endovascular Therapy, Department of Surgery, The University of Chicago, 5841 S Maryland Ave, MC 5028, Chicago, IL 60637, USA.
| | - Janez Kramberger
- Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
| |
Collapse
|
6
|
Hou X, Chikweto F, Shiraishi Y, Yambe T, Wang H, Qian Y, Hanzawa K. Finite Element Analysis of a Bare Metal Stent Therapeutic for Aortic Dissection. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40040147 DOI: 10.1109/embc53108.2024.10782596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Since the endovascular repair for aortic dissection by stent graft still has limitations of the application scope and complications, our group has been developing and evaluating a new stenting function by replacing it with a large self-expandable bare metal stent. In this study, we use finite element analysis to evaluate the remodeling outcomes of the dissected aorta by this new stent. An ideal aortic dissection model was also designed using numerical simulations based on previous animal and in vitro experiments, and then a 32mm bare metal stent was deployed at the location of the lesion. The radial force was measured by both experimental and computational methods to evaluate the mechanical performance of the bare metal stent. Results showed that two tears were successfully closed by the stent; the ratio of the lumen area between the false and true lumens was successfully decreased by more than 50% after the deployment; the diameter of the vessel did not change significantly after treatment; the stent was in good apposition with the inner wall of the aorta, but there were still small gaps and stress concentrations. The positive outcomes indicate the feasibility of this treatment and predict its long-term usage with associated fewer risks compared to the stent graft. Such analyses may provide valuable information for the design of the stent to optimize the remodeling of the true lumen and advance clinical use in the future.
Collapse
|
7
|
Mayer C, Pepe A, Hossain S, Karner B, Arnreiter M, Kleesiek J, Schmid J, Janisch M, Hannes D, Fuchsjäger M, Zimpfer D, Egger J, Mächler H. Type B Aortic Dissection CTA Collection with True and False Lumen Expert Annotations for the Development of AI-based Algorithms. Sci Data 2024; 11:596. [PMID: 38844767 PMCID: PMC11156948 DOI: 10.1038/s41597-024-03284-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Accepted: 04/22/2024] [Indexed: 06/09/2024] Open
Abstract
Aortic dissections (ADs) are serious conditions of the main artery of the human body, where a tear in the inner layer of the aortic wall leads to the formation of a new blood flow channel, named false lumen. ADs affecting the aorta distally to the left subclavian artery are classified as a Stanford type B aortic dissection (type B AD). This is linked to substantial morbidity and mortality, however, the course of the disease for the individual case is often unpredictable. Computed tomography angiography (CTA) is the gold standard for the diagnosis of type B AD. To advance the tools available for the analysis of CTA scans, we provide a CTA collection of 40 type B AD cases from clinical routine with corresponding expert segmentations of the true and false lumina. Segmented CTA scans might aid clinicians in decision making, especially if it is possible to fully automate the process. Therefore, the data collection is meant to be used to develop, train and test algorithms.
Collapse
Affiliation(s)
- Christian Mayer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Auenbruggerplatz 29, 8036, Graz, Austria
| | - Antonio Pepe
- Institute of Computer Graphics and Vision (ICG), Graz University of Technology, Inffeldgasse 16/II, 8010, Graz, Austria
| | - Sophie Hossain
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Auenbruggerplatz 29, 8036, Graz, Austria
| | - Barbara Karner
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Auenbruggerplatz 29, 8036, Graz, Austria
| | - Melanie Arnreiter
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Auenbruggerplatz 29, 8036, Graz, Austria
| | - Jens Kleesiek
- Institute for Artificial Intelligence in Medicine (IKIM), AI-guided Therapies (AIT), Essen University Hospital (AöR), Girardetstraße 2, 45131, Essen, Germany
| | - Johannes Schmid
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036, Graz, Austria
| | - Michael Janisch
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036, Graz, Austria
| | - Deutschmann Hannes
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036, Graz, Austria
| | - Michael Fuchsjäger
- Division of General Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 9, 8036, Graz, Austria
| | - Daniel Zimpfer
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Auenbruggerplatz 29, 8036, Graz, Austria
| | - Jan Egger
- Institute of Computer Graphics and Vision (ICG), Graz University of Technology, Inffeldgasse 16/II, 8010, Graz, Austria.
- Institute for Artificial Intelligence in Medicine (IKIM), AI-guided Therapies (AIT), Essen University Hospital (AöR), Girardetstraße 2, 45131, Essen, Germany.
| | - Heinrich Mächler
- Division of Cardiac Surgery, Department of Surgery, Medical University of Graz, Auenbruggerplatz 29, 8036, Graz, Austria.
| |
Collapse
|
8
|
Li M, Ma T, Cai Y, Li J, Meng Z, Dong Z, Wang S. Numerical simulation of the distal stent graft-induced new entry after TEVAR. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3819. [PMID: 38551141 DOI: 10.1002/cnm.3819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 02/16/2024] [Accepted: 03/19/2024] [Indexed: 05/15/2024]
Abstract
The study aimed to investigate the mechanical factors for distal stent graft-induced new entry (dSINE) in aortic dissection patients and discussed these factors in conjunction with aortic morphology. Two patients (one dSINE and one non-dSINE), with the same age, gender, and type of implanted stent, were selected, then aortic morphological parameters were calculated. In addition, the stent material parameters used by the patients were also fitted. Simulations were performed based on the patient's aortic model and the stent graft used. The true lumen segment at the distal stent graft was designated as the "dSINE risk zone," and mechanical parameters (maximum principal strain, maximum principal stress) were computed. When approaching the area with higher mechanical parameters in the dSINE risk zone, dSINE patient exhibited higher values and growth rates in mechanical parameters compared to non-dSINE patient. Furthermore, dSINE patient also presented larger aortic taper ratio, stent oversizing ratio, and expansion mismatch ratio of the distal true lumen (EMRDTR). The larger mechanical parameters and growth rates in dSINE patient corresponded to a greater aortic taper ratio, stent oversizing ratio, and EMRDTR. The failure of dSINE prediction by the stent tortuosity index indicated that mechanical parameters were the fundamental reasons for dSINE development.
Collapse
Affiliation(s)
- Meixuan Li
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
| | - Tao Ma
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, and National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Yunhan Cai
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
| | - Jianming Li
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
| | - Zhuangyuan Meng
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, and National Clinical Research Center for Interventional Medicine, Shanghai, China
| | - Shengzhang Wang
- Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai, China
- Institute of Biomedical Engineering Technology, Academy of Engineering and Technology, Fudan University, Shanghai, China
| |
Collapse
|
9
|
Pukaluk A, Sommer G, Holzapfel GA. Multimodal experimental studies of the passive mechanical behavior of human aortas: Current approaches and future directions. Acta Biomater 2024; 178:1-12. [PMID: 38401775 DOI: 10.1016/j.actbio.2024.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 02/14/2024] [Accepted: 02/15/2024] [Indexed: 02/26/2024]
Abstract
Cardiovascular diseases are the leading cause of death worldwide and include, among others, critical conditions of the aortic wall. Importantly, such critical conditions require effective diagnosis and treatment, which are not yet accurate enough. However, they could be significantly strengthened with predictive material models of the aortic wall. In particular, such predictive models could support surgical decisions, preoperative planning, and estimation of postoperative tissue remodeling. However, developing a predictive model requires experimental data showing both structural parameters and mechanical behavior. Such experimental data can be obtained using multimodal experiments. This review therefore discusses the current approaches to multimodal experiments. Importantly, the strength of the aortic wall is determined primarily by its passive components, i.e., mainly collagen, elastin, and proteoglycans. Therefore, this review focuses on multimodal experiments that relate the passive mechanical behavior of the human aortic wall to the structure and organization of its passive components. In particular, the multimodal experiments are classified according to the expected results. Multiple examples are provided for each experimental class and summarized with highlighted advantages and disadvantages of the method. Finally, future directions of multimodal experiments are envisioned and evaluated. STATEMENT OF SIGNIFICANCE: Multimodal experiments are innovative approaches that have gained interest very quickly, but also recently. This review presents therefore a first clear summary of groundbreaking research in the field of multimodal experiments. The benefits and limitations of various types of multimodal experiments are thoroughly discussed, and a comprehensive overview of possible results is provided. Although this review focuses on multimodal experiments performed on human aortic tissues, the methods used and described are not limited to human aortic tissues but can be extended to other soft materials.
Collapse
Affiliation(s)
- Anna Pukaluk
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering (NTNU), Trondheim, Norway.
| |
Collapse
|
10
|
Kan X, Ma T, Jiang X, Holzapfel GA, Dong Z, Xu XY. Towards biomechanics-based pre-procedural planning for thoracic endovascular aortic repair of aortic dissection. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107994. [PMID: 38159449 DOI: 10.1016/j.cmpb.2023.107994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 12/17/2023] [Accepted: 12/21/2023] [Indexed: 01/03/2024]
Abstract
BACKGROUND AND OBJECTIVE Although thoracic aortic endovascular repair (TEVAR) has shown promising outcomes in the treatment of patients with complicated type B aortic dissection, complications still occur after TEVAR that can lead to catastrophic events. Biomechanical interactions between the stent-graft (SG) and the local aortic tissue play a critical role in determining the outcome of TEVAR. Different SG design may cause different biomechanical responses in the treated aorta, but such information is not known at the time of pre-procedural planning. By developing patient-specific virtual stent-graft deployment tools, it is possible to analyse and compare the biomechanical impact of different SGs on the local aorta for individual patients. METHODS A finite element based virtual SG deployment model was employed in this study. Computational simulations were performed on a patient-specific model of type B aortic dissection, accounting for details of the SG design and the hyperelastic behaviour of the aortic wall. Based on the geometry reconstructed from the pre-TEVAR CTA scan, the patient-specific aortic dissection model was created and pre-stressed. Parametric models of three different SG products (SG1, SG2 and SG3) were built with two different lengths for each design. The SG models incorporated different stent and graft materials, stent strut patterns, and assembly approaches. Using our validated SG deployment simulation framework, virtual trials were performed on the patient-specific aortic dissection model using different SG products and varying SG lengths. CONCLUSION Simulation results for different SG products suggest that SG3 with a longer length (SG3-long) would be the most appropriate device for the individual patient. Compared to SG1-short (the SG deployed in the patient), SG3-long followed the true lumen tortuosity closely, resulted in a more uniform true lumen expansion and a significant reduction in peak stress in the distal landing zone. These simulation results are promising and demonstrate the feasibility of using the virtual SG deployment model to assist clinicians in pre-procedural planning.
Collapse
Affiliation(s)
- Xiaoxin Kan
- Centre for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China; Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Tao Ma
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; Institute of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xiaolang Jiang
- Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; Institute of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Graz, Austria; Norwegian University of Science and Technology (NTNU), Department of Structural Engineering, Trondheim, Norway
| | - Zhihui Dong
- Centre for Vascular Surgery and Wound Care, Jinshan Hospital, Fudan University, Shanghai, China; Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China; Institute of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom.
| |
Collapse
|
11
|
Mandigers TJ, Ramella A, Bissacco D, Domanin M, van Herwaarden JA, Heijmen R, Luraghi G, Migliavacca F, Trimarchi S. Thoracic Stent Graft Numerical Models To Virtually Simulate Thoracic Endovascular Aortic Repair: A Scoping Review. Eur J Vasc Endovasc Surg 2023; 66:784-796. [PMID: 37330201 DOI: 10.1016/j.ejvs.2023.06.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Revised: 05/23/2023] [Accepted: 06/06/2023] [Indexed: 06/19/2023]
Abstract
OBJECTIVE Pre-procedural planning of thoracic endovascular aortic repair (TEVAR) may implement computational adjuncts to predict technical and clinical outcomes. The aim of this scoping review was to explore the currently available TEVAR procedure and stent graft modelling options. DATA SOURCES PubMed (MEDLINE), Scopus, and Web of Science were systematically searched (English language, up to 9 December 2022) for studies presenting a virtual thoracic stent graft model or TEVAR simulation. REVIEW METHODS The Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) was followed. Qualitative and quantitative data were extracted, compared, grouped, and described. Quality assessment was performed using a 16 item rating rubric. RESULTS Fourteen studies were included. Among the currently available in silico simulations of TEVAR, severe heterogeneity exists in study characteristics, methodological details, and evaluated outcomes. Ten studies (71.4%) were published during the last five years. Eleven studies (78.6%) included heterogeneous clinical data to reconstruct patient specific aortic anatomy and disease (e.g., type B aortic dissection, thoracic aortic aneurysm) from computed tomography angiography imaging. Three studies (21.4%) constructed idealised aortic models with literature input. The applied numerical methods consisted of computational fluid dynamics analysing aortic haemodynamics in three studies (21.4%) and finite element analysis analysing structural mechanics in the others (78.6%), including or excluding aortic wall mechanical properties. The thoracic stent graft was modelled as two separate components (e.g., graft, nitinol) in 10 studies (71.4%), as a one component homogenised approximation (n = 3, 21.4%), or including nitinol rings only (n = 1, 7.1%). Other simulation components included the catheter for virtual TEVAR deployment and numerous outcomes (e.g., Von Mises stresses, stent graft apposition, drag forces) were evaluated. CONCLUSION This scoping review identified 14 severely heterogeneous TEVAR simulation models, mostly of intermediate quality. The review concludes there is a need for continuous collaborative efforts to improve the homogeneity, credibility, and reliability of TEVAR simulations.
Collapse
Affiliation(s)
- Tim J Mandigers
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Vascular Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands.
| | - Anna Ramella
- Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Milan, Italy
| | - Daniele Bissacco
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Maurizio Domanin
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| | - Joost A van Herwaarden
- Department of Vascular Surgery, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Robin Heijmen
- Department of Cardiothoracic Surgery, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Giulia Luraghi
- Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Milan, Italy
| | - Francesco Migliavacca
- Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Milan, Italy
| | - Santi Trimarchi
- Section of Vascular Surgery, Cardio Thoracic Vascular Department, Fondazione IRCCS Cà Granda Ospedale Maggiore Policlinico, Milan, Italy; Department of Clinical Sciences and Community Health, Università degli Studi di Milano, Milan, Italy
| |
Collapse
|
12
|
Isselbacher EM, Preventza O, Hamilton Black J, Augoustides JG, Beck AW, Bolen MA, Braverman AC, Bray BE, Brown-Zimmerman MM, Chen EP, Collins TJ, DeAnda A, Fanola CL, Girardi LN, Hicks CW, Hui DS, Schuyler Jones W, Kalahasti V, Kim KM, Milewicz DM, Oderich GS, Ogbechie L, Promes SB, Ross EG, Schermerhorn ML, Singleton Times S, Tseng EE, Wang GJ, Woo YJ, Faxon DP, Upchurch GR, Aday AW, Azizzadeh A, Boisen M, Hawkins B, Kramer CM, Luc JGY, MacGillivray TE, Malaisrie SC, Osteen K, Patel HJ, Patel PJ, Popescu WM, Rodriguez E, Sorber R, Tsao PS, Santos Volgman A, Beckman JA, Otto CM, O'Gara PT, Armbruster A, Birtcher KK, de las Fuentes L, Deswal A, Dixon DL, Gorenek B, Haynes N, Hernandez AF, Joglar JA, Jones WS, Mark D, Mukherjee D, Palaniappan L, Piano MR, Rab T, Spatz ES, Tamis-Holland JE, Woo YJ. 2022 ACC/AHA guideline for the diagnosis and management of aortic disease: A report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J Thorac Cardiovasc Surg 2023; 166:e182-e331. [PMID: 37389507 PMCID: PMC10784847 DOI: 10.1016/j.jtcvs.2023.04.023] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/01/2023]
Abstract
AIM The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. STRUCTURE Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.
Collapse
|
13
|
Sengupta S, Yuan X, Maga L, Pirola S, Nienaber CA, Xu XY. Aortic haemodynamics and wall stress analysis following arch aneurysm repair using a single-branched endograft. Front Cardiovasc Med 2023; 10:1125110. [PMID: 37283581 PMCID: PMC10240084 DOI: 10.3389/fcvm.2023.1125110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Accepted: 05/08/2023] [Indexed: 06/08/2023] Open
Abstract
Introduction Thoracic endovascular aortic repair (TEVAR) of the arch is challenging given its complex geometry and the involvement of supra-aortic arteries. Different branched endografts have been designed for use in this region, but their haemodynamic performance and the risk for post-intervention complications are not yet clear. This study aims to examine aortic haemodynamics and biomechanical conditions following TVAR treatment of an aortic arch aneurysm with a two-component single-branched endograft. Methods Computational fluid dynamics and finite element analysis were applied to a patient-specific case at different stages: pre-intervention, post-intervention and follow-up. Physiologically accurate boundary conditions were used based on available clinical information. Results Computational results obtained from the post-intervention model confirmed technical success of the procedure in restoring normal flow to the arch. Simulations of the follow-up model, where boundary conditions were modified to reflect change in supra-aortic vessel perfusion observed on the follow-up scan, predicted normal flow patterns but high levels of wall stress (up to 1.3M MPa) and increased displacement forces in regions at risk of compromising device stability. This might have contributed to the suspected endoleaks or device migration identified at the final follow up. Discussion Our study demonstrated that detailed haemodynamic and biomechanical analysis can help identify possible causes for post-TEVAR complications in a patient-specific setting. Further refinement and validation of the computational workflow will allow personalised assessment to aid in surgical planning and clinical decision making.
Collapse
Affiliation(s)
- Sampad Sengupta
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Xun Yuan
- National Heart and Lung Institute, Faculty of Medicine, Imperial College London, London, United Kingdom
- Cardiology and Aortic Centre, Royal Brompton and Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, London, United Kingdom
| | - Ludovica Maga
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- Department of Biomechanical Engineering, Delft University of Technology, Delft, Netherlands
| | - Selene Pirola
- Department of Biomechanical Engineering, Delft University of Technology, Delft, Netherlands
| | - Christoph A. Nienaber
- National Heart and Lung Institute, Faculty of Medicine, Imperial College London, London, United Kingdom
- Cardiology and Aortic Centre, Royal Brompton and Harefield Hospitals, Guy’s and St Thomas’ NHS Foundation Trust, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
14
|
Zhu Y, Xu XY, Rosendahl U, Pepper J, Mirsadraee S. Advanced risk prediction for aortic dissection patients using imaging-based computational flow analysis. Clin Radiol 2023; 78:e155-e165. [PMID: 36610929 DOI: 10.1016/j.crad.2022.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 11/28/2022] [Accepted: 12/02/2022] [Indexed: 12/24/2022]
Abstract
Patients with either a repaired or medically managed aortic dissection have varying degrees of risk of developing late complications. High-risk patients would benefit from earlier intervention to improve their long-term survival. Currently serial imaging is used for risk stratification, which is not always reliable. On the other hand, understanding aortic haemodynamics within a dissection is essential to fully evaluate the disease and predict how it may progress. In recent decades, computational fluid dynamics (CFD) has been extensively applied to simulate complex haemodynamics within aortic diseases, and more recently, four-dimensional (4D)-flow magnetic resonance imaging (MRI) techniques have been developed for in vivo haemodynamic measurement. This paper presents a comprehensive review on the application of image-based CFD simulations and 4D-flow MRI analysis for risk prediction in aortic dissection. The key steps involved in patient-specific CFD analyses are demonstrated. Finally, we propose a workflow incorporating computational modelling for personalised assessment to aid in risk stratification and treatment decision-making.
Collapse
Affiliation(s)
- Y Zhu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - X Y Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - U Rosendahl
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, UK; National Heart and Lung Institute, Imperial College London, London, UK
| | - J Pepper
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, UK; National Heart and Lung Institute, Imperial College London, London, UK
| | - S Mirsadraee
- National Heart and Lung Institute, Imperial College London, London, UK; Department of Radiology, Royal Brompton and Harefield Hospitals, London, UK.
| |
Collapse
|
15
|
Ramella A, Migliavacca F, Rodriguez Matas JF, Mandigers TJ, Bissacco D, Domanin M, Trimarchi S, Luraghi G. Applicability assessment for in-silico patient-specific TEVAR procedures. J Biomech 2023; 146:111423. [PMID: 36584506 DOI: 10.1016/j.jbiomech.2022.111423] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 12/05/2022] [Accepted: 12/23/2022] [Indexed: 12/25/2022]
Abstract
Thoracic Endovascular Aortic Repair (TEVAR) is a minimally invasive technique to treat thoracic aorta pathologies and consists of placing a self-expandable stent-graft into the pathological region to restore the vessel lumen and recreate a more physiological condition. Exhaustive computational models, namely the finite element analysis, can be implemented to reproduce the clinical procedure. In this context, numerical models, if used for clinical applications, must be reliable and the simulation credibility should be proved to predict clinical procedure outcomes or to build in-silico clinical trials. This work aims first at applying a previously validated TEVAR methodology to a patient-specific case. Then, defining the TEVAR procedure performed on a patient population as the context of use, the overall applicability of the TEVAR modeling is assessed to demonstrate the reliability of the model itself following a step-by-step method based on the ASME V&V40 protocol. Validation evidence sources are identified for the specific context of use and adopted to demonstrate the applicability of the numerical procedure, thereby answering a question of interest that evaluates the deployed stent-graft configuration in the vessel.
Collapse
Affiliation(s)
- Anna Ramella
- Department of Chemistry, Materials and Chemical Engineering, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Francesco Migliavacca
- Department of Chemistry, Materials and Chemical Engineering, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Jose Felix Rodriguez Matas
- Department of Chemistry, Materials and Chemical Engineering, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Tim J Mandigers
- Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Daniele Bissacco
- Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Maurizio Domanin
- Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Santi Trimarchi
- Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Giulia Luraghi
- Department of Chemistry, Materials and Chemical Engineering, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy.
| |
Collapse
|
16
|
Isselbacher EM, Preventza O, Hamilton Black J, Augoustides JG, Beck AW, Bolen MA, Braverman AC, Bray BE, Brown-Zimmerman MM, Chen EP, Collins TJ, DeAnda A, Fanola CL, Girardi LN, Hicks CW, Hui DS, Schuyler Jones W, Kalahasti V, Kim KM, Milewicz DM, Oderich GS, Ogbechie L, Promes SB, Gyang Ross E, Schermerhorn ML, Singleton Times S, Tseng EE, Wang GJ, Woo YJ. 2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. Circulation 2022; 146:e334-e482. [PMID: 36322642 PMCID: PMC9876736 DOI: 10.1161/cir.0000000000001106] [Citation(s) in RCA: 778] [Impact Index Per Article: 259.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
AIM The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. Structure: Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Bruce E Bray
- AHA/ACC Joint Committee on Clinical Data Standards liaison
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | - Y Joseph Woo
- AHA/ACC Joint Committee on Clinical Practice Guidelines liaison
| |
Collapse
|
17
|
Isselbacher EM, Preventza O, Hamilton Black Iii J, Augoustides JG, Beck AW, Bolen MA, Braverman AC, Bray BE, Brown-Zimmerman MM, Chen EP, Collins TJ, DeAnda A, Fanola CL, Girardi LN, Hicks CW, Hui DS, Jones WS, Kalahasti V, Kim KM, Milewicz DM, Oderich GS, Ogbechie L, Promes SB, Ross EG, Schermerhorn ML, Times SS, Tseng EE, Wang GJ, Woo YJ. 2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease: A Report of the American Heart Association/American College of Cardiology Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol 2022; 80:e223-e393. [PMID: 36334952 PMCID: PMC9860464 DOI: 10.1016/j.jacc.2022.08.004] [Citation(s) in RCA: 233] [Impact Index Per Article: 77.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AIM The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. STRUCTURE Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.
Collapse
|
18
|
Zhu Y, Mirsadraee S, Rosendahl U, Pepper J, Xu XY. Fluid-Structure Interaction Simulations of Repaired Type A Aortic Dissection: a Comprehensive Comparison With Rigid Wall Models. Front Physiol 2022; 13:913457. [PMID: 35774287 PMCID: PMC9237394 DOI: 10.3389/fphys.2022.913457] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Accepted: 05/17/2022] [Indexed: 11/26/2022] Open
Abstract
This study aimed to evaluate the effect of aortic wall compliance on intraluminal hemodynamics within surgically repaired type A aortic dissection (TAAD). Fully coupled two-way fluid-structure interaction (FSI) simulations were performed on two patient-specific post-surgery TAAD models reconstructed from computed tomography angiography images. Our FSI model incorporated prestress and different material properties for the aorta and graft. Computational results, including velocity, wall shear stress (WSS) and pressure difference between the true and false lumen, were compared between the FSI and rigid wall simulations. It was found that the FSI model predicted lower blood velocities and WSS along the dissected aorta. In particular, the area exposed to low time-averaged WSS ( ≤ 0.2 P a ) was increased from 21 cm2 (rigid) to 38 cm2 (FSI) in patient 1 and from 35 cm2 (rigid) to 144 cm2 (FSI) in patient 2. FSI models also produced more disturbed flow where much larger regions presented with higher turbulence intensity as compared to the rigid wall models. The effect of wall compliance on pressure difference between the true and false lumen was insignificant, with the maximum difference between FSI and rigid models being less than 0.25 mmHg for the two patient-specific models. Comparisons of simulation results for models with different Young's moduli revealed that a more compliant wall resulted in further reduction in velocity and WSS magnitudes because of increased displacements. This study demonstrated the importance of FSI simulation for accurate prediction of low WSS regions in surgically repaired TAAD, but a rigid wall computational fluid dynamics simulation would be sufficient for prediction of luminal pressure difference.
Collapse
Affiliation(s)
- Yu Zhu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| | - Saeed Mirsadraee
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Radiology, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - Ulrich Rosendahl
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - John Pepper
- National Heart and Lung Institute, Imperial College London, London, United Kingdom
- Department of Cardiac Surgery, Royal Brompton and Harefield Hospitals, London, United Kingdom
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, United Kingdom
| |
Collapse
|
19
|
Armour CH, Guo B, Saitta S, Pirola S, Liu Y, Dong Z, Xu XY. Evaluation and verification of patient-specific modelling of type B aortic dissection. Comput Biol Med 2022; 140:105053. [PMID: 34847383 DOI: 10.1016/j.compbiomed.2021.105053] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 11/16/2021] [Accepted: 11/16/2021] [Indexed: 02/07/2023]
Abstract
Quantitative assessment of the complex hemodynamic environment in type B aortic dissection (TBAD) through computational fluid dynamics (CFD) simulations can provide detailed insights into the disease and its progression. As imaging and computational technologies have advanced, methodologies have been developed to increase the accuracy and physiological relevance of CFD simulations. This study presents a patient-specific workflow to simulate blood flow in TBAD, utilising the maximum amount of in vivo data available in the form of CT images, 4D-flow MRI and invasive Doppler-wire pressure measurements, to implement the recommended current best practice methodologies in terms of patient-specific geometry and boundary conditions. The study aimed to evaluate and verify this workflow through detailed qualitative and quantitative comparisons of the CFD and in vivo data. Based on data acquired from five TBAD patients, a range of essential model inputs was obtained, including inlet flow waveforms and 3-element Windkessel model parameters, which can be utilised in further studies where in vivo flow data is not available. Local and global analysis showed good consistency between CFD results and 4D-MRI data, with the maximum velocity in the primary entry tear differing by up to 0.3 m/s, and 80% of the analysed regions achieving moderate or strong correlations between the predicted and in vivo velocities. CFD predicted pressures were generally well matched to the Doppler-wire measurements, with some deviation in peak systolic values. Overall, this study presents a validated comprehensive workflow with extensive data for CFD simulation of TBAD.
Collapse
Affiliation(s)
- Chlöe H Armour
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Baolei Guo
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
| | - Simone Saitta
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK; Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Selene Pirola
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Yifan Liu
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China
| | - Zhihui Dong
- Department of Vascular Surgery, Zhongshan Hospital, Institute of Vascular Surgery, Fudan University, Shanghai, China.
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK.
| |
Collapse
|
20
|
Ramella A, Migliavacca F, Rodriguez Matas JF, Heim F, Dedola F, Marconi S, Conti M, Allievi S, Mandigers TJ, Bissacco D, Domanin M, Trimarchi S, Luraghi G. Validation and Verification of High-Fidelity Simulations of Thoracic Stent-Graft Implantation. Ann Biomed Eng 2022; 50:1941-1953. [PMID: 35854187 PMCID: PMC9794542 DOI: 10.1007/s10439-022-03014-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 07/08/2022] [Indexed: 12/31/2022]
Abstract
Thoracic Endovascular Aortic Repair (TEVAR) is the preferred treatment option for thoracic aortic pathologies and consists of inserting a self-expandable stent-graft into the pathological region to restore the lumen. Computational models play a significant role in procedural planning and must be reliable. For this reason, in this work, high-fidelity Finite Element (FE) simulations are developed to model thoracic stent-grafts. Experimental crimp/release tests are performed to calibrate stent-grafts material parameters. Stent pre-stress is included in the stent-graft model. A new methodology for replicating device insertion and deployment with explicit FE simulations is proposed. To validate this simulation, the stent-graft is experimentally released into a 3D rigid aortic phantom with physiological anatomy and inspected in a computed tomography (CT) scan at different time points during deployment with an ad-hoc set-up. A verification analysis of the adopted modeling features compared to the literature is performed. With the proposed methodology the error with respect to the CT is on average 0.92 ± 0.64%, while it is higher when literature models are adopted (on average 4.77 ± 1.83%). The presented FE tool is versatile and customizable for different commercial devices and applicable to patient-specific analyses.
Collapse
Affiliation(s)
- Anna Ramella
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Francesco Migliavacca
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Jose Felix Rodriguez Matas
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - Frederic Heim
- grid.9156.b0000 0004 0473 5039Laboratoire de Physique et Mécanique des Textiles, Université de Haute-Alsace, 11 rue Alfred Werner, 68093 Mulhouse, France
| | - Francesca Dedola
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy
| | - Stefania Marconi
- grid.8982.b0000 0004 1762 5736Department of Civil Engineering and Architecture (DICAr), University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Michele Conti
- grid.8982.b0000 0004 1762 5736Department of Civil Engineering and Architecture (DICAr), University of Pavia, Via Ferrata 3, 27100 Pavia, Italy
| | - Sara Allievi
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy
| | - Tim J. Mandigers
- grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Daniele Bissacco
- grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Maurizio Domanin
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy ,grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Santi Trimarchi
- grid.4708.b0000 0004 1757 2822Clinical and Community Sciences Department, Università degli Studi di Milano, Via della Commenda 19, 20122 Milan, Italy ,grid.414818.00000 0004 1757 8749Unit of Vascular Surgery, I.R.C.C.S. Fondazione Cà Granda Policlinico Milano, Via Francesco Sforza 35, Milan, Italy
| | - Giulia Luraghi
- grid.4643.50000 0004 1937 0327Computational Biomechanics Laboratory – LaBS, Department of Chemistry, Materials and Chemical Engineering ‘Giulio Natta’, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| |
Collapse
|
21
|
Modelling Combined Intravenous Thrombolysis and Mechanical Thrombectomy in Acute Ischaemic Stroke: Understanding the Relationship between Stent Retriever Configuration and Clot Lysis Mechanisms. Life (Basel) 2021; 11:life11111271. [PMID: 34833146 PMCID: PMC8625756 DOI: 10.3390/life11111271] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/10/2021] [Accepted: 11/18/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Combined intravenous thrombolysis and mechanical thrombectomy (IVT-MT) is a common treatment in acute ischaemic stroke, however the interaction between IVT and MT from a physiological standpoint is poorly understood. In this pilot study, we conduct numerical simulations of combined IVT-MT with various idealised stent retriever configurations to evaluate performance in terms of complete recanalisation times and lysis patterns. Methods: A 3D patient-specific geometry of a terminal internal carotid artery with anterior and middle cerebral arteries is reconstructed, and a thrombus is artificially implanted in the MCA branch. Various idealised stent retriever configurations are implemented by varying stent diameter and stent placement, and a configuration without a stent retriever provides a baseline for comparison. A previously validated multi-level model of thrombolysis is used, which incorporates blood flow, drug transport, and fibrinolytic reactions within a fibrin thrombus. Results: Fastest total recanalisation was achieved in the thrombus without a stent retriever, with lysis times increasing with stent retriever diameter. Two mechanisms of clot lysis were established: axial and radial permeation. Axial permeation from the clot front was the primary mechanism of lysis in all configurations, as it facilitated increased protein binding with fibrin fibres. Introducing a stent retriever channel allowed for radial permeation, which occurred at the fluid-thrombus interface, although lysis was much slower in the radial direction because of weaker secondary velocities. Conclusions: Numerical models can be used to better understand the complex physiological relationship between IVT and MT. Two different mechanisms of lysis were established, providing a basis towards improving the efficacy of combined treatments.
Collapse
|
22
|
Gamage PT, Dong P, Lee J, Gharaibeh Y, Zimin VN, Dallan LAP, Bezerra HG, Wilson DL, Gu L. Hemodynamic alternations following stent deployment and post-dilation in a heavily calcified coronary artery: In silico and ex-vivo approaches. Comput Biol Med 2021; 139:104962. [PMID: 34715552 DOI: 10.1016/j.compbiomed.2021.104962] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 10/16/2021] [Accepted: 10/17/2021] [Indexed: 01/16/2023]
Abstract
In this work, hemodynamic alterations in a patient-specific, heavily calcified coronary artery following stent deployment and post-dilations are quantified using in silico and ex-vivo approaches. Three-dimensional artery models were reconstructed from OCT images. Stent deployment and post-dilation with various inflation pressures were performed through both the finite element method (FEM) and ex vivo experiments. Results from FEM agreed very well with the ex-vivo measurements, interms of lumen areas, stent underexpansion, and strut malapposition. In addition, computational fluid dynamics (CFD) simulations were performed to delineate the hemodynamic alterations after stent deployment and post-dilations. A pressure time history at the inlet and a lumped parameter model (LPM) at the outlet were adopted to mimic the aortic pressure and the distal arterial tree, respectively. The pressure drop across the lesion, pertaining to the clinical measure of instantaneous wave-free flow ratio (iFR), was investigated. Results have shown that post-dilations are necessary for the lumen gain as well as the hemodynamic restoration towards hemostasis. Malapposed struts induced much higher shear rate, flow disturbances and lower time-averaged wall shear stress (TAWSS) around struts. Post-dilations mitigated the strut malapposition, and thus the shear rate. Moreover, stenting induced larger area of low TAWSS (<0.4 Pa) and lager volume of high shear rate (>2000 s-1), indicating higher risks of in-stent restenosis (ISR) and stent thrombosis (ST), respectively. Oscillatory shear index (OSI) and relative residence time (RRT) indicated the wall regions more prone to ISR are located near the malapposed stent struts.
Collapse
Affiliation(s)
- Peshala T Gamage
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, 32901, USA
| | - Pengfei Dong
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, 32901, USA.
| | - Juhwan Lee
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Yazan Gharaibeh
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Vladislav N Zimin
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, 44106, USA
| | - Luis A P Dallan
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, 44106, USA
| | - Hiram G Bezerra
- Interventional Cardiology Center, Heart and Vascular Institute, The University of South Florida, Tampa, FL, 33606, USA
| | - David L Wilson
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Linxia Gu
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, 32901, USA.
| |
Collapse
|