1
|
Latia M, Bena A, Moisa-Luca L, Bunceanu Ș, Stoian D. Shear wave elastography for thyroid nodule evaluation in patients with chronic autoimmune thyroiditis. Endocrine 2025; 88:482-490. [PMID: 39827288 PMCID: PMC12069123 DOI: 10.1007/s12020-025-04159-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2024] [Accepted: 01/07/2025] [Indexed: 01/22/2025]
Abstract
PURPOSE Shear wave elastography (SWE) is a valuable tool in discerning the malignancy risk of thyroid nodules. This study investigates whether 2D-SWE can reliably differentiate malignant thyroid nodules in patients with chronic autoimmune thyroiditis (CAT), despite the challenges posed by fibrosis, which can increase tissue stiffness and complicate diagnosis. METHODS This retrospective observational study evaluated 130 thyroid nodules (91 benign, 39 malignant) in patients with underlying CAT using conventional ultrasound (B-mode) and 2D-SWE with SuperSonic Mach30 equipment (Supersonic Imagine, Aix-en-Provence, France). Pathology reports served as the reference standard. RESULTS Out of the 130 nodules, 30% were malignant, and 70% were benign. 2D-SWE proved to be an excellent distinguisher between benign and malignant nodules. Malignant nodules had significantly higher elasticity indices compared to benign nodules (mean elasticity index: 47.2 kPa vs. 18.1 kPa, p < 0.0001; maximum elasticity index: 75 kPa vs. 26.2 kPa, p < 0.0001). The mean elasticity index was the most reliable elastographic parameter (AUC 0.907, sensitivity 87.2% [95% CI: 77.3-94.0%], specificity 84.6% [95% CI: 75.4-91.5%], and NPV 93.9% for a cut-off value of 30.5 kPa). CONCLUSION Our results confirm that 2D-SWE can accurately diagnose malignant thyroid nodules in cases with CAT (p < 0.0001), supporting its use as a complementary tool to conventional ultrasound.
Collapse
Affiliation(s)
- Monica Latia
- Department of Doctoral Studies, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania
| | - Andreea Bena
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania.
- Center of Molecular Research in Nephrology and Vascular Disease, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania.
- Discipline of Endocrinology, Second Department of Internal Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania.
- Endocrinology Unit, Pius Brinzeu Emergency Clinical Hospital, Timisoara, Romania.
| | - Luciana Moisa-Luca
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania
- Center of Molecular Research in Nephrology and Vascular Disease, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Discipline of Endocrinology, Second Department of Internal Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
| | - Ștefania Bunceanu
- Department of Doctoral Studies, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
| | - Dana Stoian
- Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania
- Center of Molecular Research in Nephrology and Vascular Disease, Faculty of Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Discipline of Endocrinology, Second Department of Internal Medicine, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
- Endocrinology Unit, Pius Brinzeu Emergency Clinical Hospital, Timisoara, Romania
| |
Collapse
|
2
|
Borysewicz-Sańczyk H, Bossowski F, Anikiej K, Sawicka B, Michalak J, Dzięcioł J, Bossowski A. Application of shear wave elastography in the management of thyroid nodules in children and adolescents: our experience and a review of the literature. Front Endocrinol (Lausanne) 2024; 15:1486285. [PMID: 39634183 PMCID: PMC11614656 DOI: 10.3389/fendo.2024.1486285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2024] [Accepted: 10/25/2024] [Indexed: 12/07/2024] Open
Abstract
Introduction Shear wave elastography (SWE) is an ultrasound diagnostic method used to measure tissue stiffness. Since the mechanical properties of tissue involved in the pathological process change, SWE might indicate regions of the examined tissue covered by the disease. It is well documented that SWE helps to differentiate benign and malignant nodules in thyroid glands in adults, however, there are few studies on the application of SWE in thyroid diagnosis in children. The purpose of the study was to assess the application of SWE based on Young's modulus expressed in kPa in the management of thyroid nodules in children and adolescents. Methods In total, 116 pediatric patients (81 girls and 35 boys) with 168 thyroid nodules were enrolled in the study and qualified for SWE followed by fine needle aspiration biopsy. Results According to the result of the cytological examination presented in the Bethesda System, nodules were classified as benign (147 nodules classified as category II according to the Bethesda System) or indeterminate or suspicious (21 nodules classified as categories III, IV, and V according to the Bethesda System). Benign cytological diagnoses were nodular goiter, parenchymal goiter, nodular colloid goiter, or lymphocytic inflammation. Among the indeterminate or suspicious nodules, 15 were diagnosed as category III according to the Bethesda System (atypia of undetermined significance (AUS) or follicular lesion of undetermined significance (FLUS) in cytology), 1 nodule was diagnosed as category IV according to the Bethesda System (suspicious for follicular neoplasm - oxyphilic cell tumor), and 5 as category V according to the Bethesda System (suspicious for malignancy). There were no significant differences in thyrotropin (TSH) and free thyroxine (fT4) concentrations between the benign and suspicious groups. Patients with benign and indeterminate or suspicious thyroid nodules were of comparable age. Mean SWE in benign nodules was statistically significantly lower than in nodules with indeterminate or suspicious cytology (42.22 ± 16.69 vs. 57.4 ± 24.0 kPa, p=0.0004). Six patients from the indeterminate or suspicious group were revealed to be malignant in the final histopathological examination. Conclusion Our results suggest that SWE is a viable diagnostic method, however, it still seems to need some adjustment for pediatric patients.
Collapse
Affiliation(s)
- Hanna Borysewicz-Sańczyk
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Filip Bossowski
- Student Research Group by the Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Katarzyna Anikiej
- Student Research Group by the Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Beata Sawicka
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Justyna Michalak
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| | - Janusz Dzięcioł
- Department of Human Anatomy, Medical University of Bialystok, Bialystok, Poland
| | - Artur Bossowski
- Department of Pediatrics, Endocrinology, Diabetology with Cardiology Divisions, Medical University of Bialystok, Bialystok, Poland
| |
Collapse
|
3
|
Angelopoulos N, Goulis DG, Chrisogonidis I, Livadas S, Iakovou I. Color Doppler ultrasound and real-time elastography in patients with hypothyroidism for the prediction of levothyroxine replacement: a cross-sectional study of 338 patients. J Ultrasound 2024; 27:363-373. [PMID: 38393451 PMCID: PMC11178754 DOI: 10.1007/s40477-024-00876-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Accepted: 01/23/2024] [Indexed: 02/25/2024] Open
Abstract
AIMS While hormonal assays are commonly used for thyroid function assessment, Doppler sonography provides valuable information on vascularization and blood flow. This study aimed to examine the potential associations between Doppler parameters and clinical characteristics of hypothyroid patients, such as the autoimmune nature of the disease and adequacy of LT4 replacement. METHODS A total of 338 patients with hypothyroidism, primarily caused by autoimmune thyroiditis (AT), were enrolled in this study. Exclusion criteria comprised specific medical conditions, medication history, and nodular abnormalities of the thyroid gland. Patient demographics (age, sex, BMI), treatment parameters (LT4 daily dose), and thyroid hormone levels (TSH, fT4) were recorded. RESULTS Among the enrolled patients, 85.2% had autoimmune thyroiditis. Suboptimal levothyroxine (LT4) replacement was observed in 20.1% of patients at the time of enrollment. Patients with autoimmune thyroiditis had increased elastography ratios compared to those without autoimmune disease and present a positive association of elastography ratios with vascularity. In patients without autoimmune thyroiditis, those with suboptimal LT4 replacement had lower total thyroid volume. Patients with suboptimal LT4 replacement had higher peak systolic velocity (PSV) and end-diastolic velocity (EDV) in the inferior thyroid artery and lower resistive index (RI). The severity of hypothyroidism, as indicated by LT4 dose/body mass index (BMI), was negatively correlated with thyroid volume and EDV values of superior and inferior thyroid arteries. PSV of the inferior thyroid artery can predict suboptimal LT4 replacement (sensitivity 81.8%, specificity 42%). CONCLUSIONS In situations where obtaining blood tests may be challenging, utilizing color Doppler ultrasound can serve as an alternative method to assess treatment responses and identify patients who require further hormonal examinations.
Collapse
Affiliation(s)
- Nikolaos Angelopoulos
- 2nd Academic Department of Nuclear Medicine, Faculty of Medicine, School of Health Sciences, AHEPA University Hospital, Venizelou 26, Kavala, 65403, Thessaloniki, Greece.
| | - Dimitrios G Goulis
- Unit of Reproductive Endocrinology, 1st Department of Obstetrics and Gynecology, Faculty of Medicine, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Ioannis Chrisogonidis
- Department of Radiology, Faculty of Medicine, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | | | - Ioannis Iakovou
- 2nd Academic Department of Nuclear Medicine, Faculty of Medicine, School of Health Sciences, AHEPA University Hospital, Venizelou 26, Kavala, 65403, Thessaloniki, Greece
| |
Collapse
|
4
|
Stoian D, Borlea A, Moisa-Luca L, Paul C. Multiparametric ultrasound-based assessment of overt hyperthyroid diffuse thyroid disease. Front Endocrinol (Lausanne) 2023; 14:1300447. [PMID: 38179308 PMCID: PMC10764279 DOI: 10.3389/fendo.2023.1300447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 11/30/2023] [Indexed: 01/06/2024] Open
Abstract
Introduction Hyperthyroidismis a prevalent condition affecting global populations, with an overall prevalence of 1.2%. Our research aimed to establish a systematic diagnostic approach using multiparametric ultrasound (MPUS) to diagnose hyperthyroid diffuse thyroid disease (DTD). Methods We conducted a retrospective study from June 2021 to June 2023 at a specialized endocrinology center in Timisoara, Romania, enrolling subjects presenting with clinical hyperthyroidism. Using the Mach 30 Aixplorer ultrasound equipment, evaluations were performed initially in B-mode US, followed by Color Doppler and Spectral Doppler measurements, and finally, 2D Shear wave elastography (SWE). Results From the 218 patients analyzed, the diagnosis of DTD with hyperthyroidism was confirmed through biochemical assessment, subgrouping various pathologies such as subacute thyroiditis, Graves' disease, painless thyroiditis, Hashimoto's thyroiditis, iatrogenic, as well as healthy controls. In the first step, B-mode hypoechogenicity had an AUC of 0.951 for DTD detection. In the second step, the peak systolic velocity differentiated Graves' disease with a median of 42.4 cm/s and an AUC of 1. Lastly, the third step consisted of SWE evaluation, revealing a mean elasticity index in the SAT subgroup significantly higher from other subgroups (p<0.001) with an AUC of 1. Conclusion Our study offers a step-by-step evaluation algorithm for DTD diagnosis, with a very good overall diagnostic performance (AUC of 0.946).
Collapse
Affiliation(s)
- Dana Stoian
- Discipline of Endocrinology, Second Department of Internal Medicine, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
- Center for Molecular Research in Nephrology and Vascular Disease, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
| | - Andreea Borlea
- Discipline of Endocrinology, Second Department of Internal Medicine, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
- Center for Molecular Research in Nephrology and Vascular Disease, “Victor Babes” University of Medicine and Pharmacy, Timisoara, Romania
| | - Luciana Moisa-Luca
- Discipline of Endocrinology, Second Department of Internal Medicine, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
| | - Corina Paul
- Department of Pediatrics, University of Medicine and Pharmacy “Victor Babes”, Timisoara, Romania
| |
Collapse
|
5
|
Hoshi M, Jikuzono T, Suzuki S, Ishibashi O, Kawamoto Y, Kure S, Kawamoto M, Ohashi R, Sugitani I. Use of Ultrasonographic Shear Wave Measurements to Diagnose Thyroid Metastasis from Breast Carcinoma. J NIPPON MED SCH 2023; 90:398-403. [PMID: 35644558 DOI: 10.1272/jnms.jnms.2023_90-501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
A metastatic thyroid tumor (MTT) arising from breast carcinoma (BC) is rare and sometimes difficult to diagnose. We present a case of MTT from BC; we suspected anaplastic thyroid carcinoma at initial presentation. The patient was a 58-year-old female with a hard nodule in the right anterior neck and a history of breast cancer. Computed tomography indicated tumors on both thyroid lobes, and ultrasonography (US) with shear wave measurement (SWM) showed malignant features. We performed fine needle aspiration cytology (FNAC), the results of which led us to strongly suspect MTT from BC. The surgically resected specimen was evaluated histopathologically, including by immunohistochemistry (IHC), and the diagnosis was confirmed. In addition to FNAC and IHC, SWM is useful to diagnose MTT from BC.
Collapse
Affiliation(s)
- Masae Hoshi
- Department of Endocrine Surgery, Kanaji Thyroid Hospital
| | | | | | - Osamu Ishibashi
- Department of Endocrine Surgery, Nippon Medical School
- Laboratory of Biological Macromolecules, Department of Applied Life Sciences, Graduate School of Life & Environmental Sciences, Osaka Prefecture University
| | - Yoko Kawamoto
- Department of Integrated Diagnostic Pathology, Nippon Medical School
| | - Shoko Kure
- Department of Integrated Diagnostic Pathology, Nippon Medical School
| | - Masashi Kawamoto
- Department of Diagnostic Pathology, Shonan Fujisawa Tokushukai Hospital
| | - Ryuji Ohashi
- Department of Integrated Diagnostic Pathology, Nippon Medical School
| | - Iwao Sugitani
- Department of Endocrine Surgery, Nippon Medical School
| |
Collapse
|
6
|
Roi CM, Borlea A, Mihuta MS, Paul C, Stoian D. A Comparative Analysis of Strain and 2D Shear Wave Elastography in the Diagnosis of Autoimmune Thyroiditis in Pediatric Patients. Biomedicines 2023; 11:1970. [PMID: 37509609 PMCID: PMC10376998 DOI: 10.3390/biomedicines11071970] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 06/29/2023] [Accepted: 07/11/2023] [Indexed: 07/30/2023] Open
Abstract
This paper aims to assess the usefulness of shear-wave elastography (SWE) and strain elastography (SE) for identifying and monitoring thyroid gland changes in children diagnosed with chronic autoimmune thyroiditis (CAT). Our study included 77 children between the ages of six and eighteen. Of these, 45 were diagnosed with CAT, while 32 had no thyroid pathology. Following a clinical examination and laboratory tests, an ultrasound was carried out, and then a SE (using a Hitachi Preirus machine) and SWE (using an Aixplorer Mach 30, Supersonic imagine, France) were performed in the same session. The median thyroid elastic index (EI) in the CAT group was 13.8 (13.3-17) kPa compared to 10.1 (9.3-11.2) kPa in healthy children (p < 0.0001). We found a median strain ratio (SR) of 1.2 (1.2-1.3) for CAT compared to 0.7 (0.6-0.9) for healthy thyroid tissue (p < 0.0001). The optimal cut-off value for predicting the presence of CAT in children using SR was >1 (Se = 82.2%, Sp = 87.5%, PPV = 90.2%, and NPV = 77.8%, AUROC = 0.850), while using SWE, the optimal cut-off value for predicting the presence of CAT in children was >12 kPa (Se = 88.9%, Sp = 93.7%, PPV = 95.2%, and NPV = 85.5%, AUROC = 0.943). Both techniques are useful for measuring thyroid tissue elasticity, and their diagnostic accuracy and reliability are comparable.
Collapse
Affiliation(s)
- Cristina Mihaela Roi
- Department of Doctoral Studies, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Andreea Borlea
- Department of Internal Medicine II, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Monica Simina Mihuta
- Department of Doctoral Studies, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Corina Paul
- Department of Pediatrics, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Dana Stoian
- Department of Internal Medicine II, Victor Babes University of Medicine and Pharmacy, 300041 Timisoara, Romania
| |
Collapse
|
7
|
Stoian D, Borlea A, Sporea I, Popa A, Moisa-Luca L, Popescu A. Assessment of Thyroid Stiffness and Viscosity in Autoimmune Thyroiditis Using Novel Ultrasound-Based Techniques. Biomedicines 2023; 11:938. [PMID: 36979917 PMCID: PMC10046469 DOI: 10.3390/biomedicines11030938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/03/2023] [Accepted: 03/14/2023] [Indexed: 03/30/2023] Open
Abstract
The estimation of viscosity by measuring the shear-wave dispersion (SWD) using ultrasound 2D shear-wave elastography (SWE) is becoming more and more popular. Recent research suggests that SWD can be used in addition to 2D-SWE (shear-wave speed) to diagnose diffuse liver disease. Viscosity was studied for the assessment of normal thyroid tissue. This study aims to evaluate the use of viscosity measurements in patients with chronic autoimmune thyroiditis using the SuperSonic MACH®30 ultrasound machine (Hologic SuperSonic Imagine, Aix-en-Provence, France) which provides the Vi PLUS mode for viscosity and the 2D SWE PLUS mode for shear-wave speed measurements. Valid measurements were obtained in 308 cases, 153 with chronic autoimmune thyroiditis (CAT) and 155 with no thyroid pathology (95.95% feasibility of the methods). The differences between the healthy group and the CAT group were statistically significant both for Vi PLUS (2.5 ± 0.4 vs. 2.8 ± 0.5, p < 0.0001) and for 2D-SWE PLUS (13.5 ± 3.3 vs. 23.1 ± 8.3, p < 0.0001). The diagnostic performance was poor for Vi PLUS alone (AUC = 0.69; cut-off > 2.5 Pa·s, se = 68.6%; sp = 64.52%) and good for 2D-SWE PLUS alone (AUC = 0.861; cut-off > 18.4 kPa, se = 69.9%; sp = 92.2%). Vi PLUS correlated with 2D-SWE PLUS, with the presence of CAT, the thyroid volume, levothyroxine replacement therapy and age. Statistically significant differences were found between the CAT subgroup receiving thyroid replacement therapy and the subgroup without therapy: 24.74 ± 8.33 vs. 21.93 ± 8.12 kPa for 2D-SWE (p = 0.0380) and 3 ± 0.5 vs. 2.7 ± 0.4 Pa·s for Vi PLUS (p = 0.0193). Elastography-based methods improve the classic ultrasound evaluation: 2D-SWE PLUS performed somewhat better in distinguishing CAT from normal thyroid tissue, while Vi PLUS made a slightly better assessment regarding the functional status.
Collapse
Affiliation(s)
- Dana Stoian
- Division of Endocrinology, Department of Internal Medicine II, “Victor Babeș” University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania
- DrD Ultrasound Center, M. Cristea Nr. 9, 300029 Timisoara, Romania
- Centre for Molecular Research in Nephrology and Vascular Disease, “Victor Babeș” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Andreea Borlea
- Division of Endocrinology, Department of Internal Medicine II, “Victor Babeș” University of Medicine and Pharmacy, E. Murgu Square, Nr. 2, 300041 Timisoara, Romania
- DrD Ultrasound Center, M. Cristea Nr. 9, 300029 Timisoara, Romania
- Centre for Molecular Research in Nephrology and Vascular Disease, “Victor Babeș” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Ioan Sporea
- Division of Gastroenterology and Hepatology, Department of Internal Medicine II, Victor Babeș University of Medicine and Pharmacy, 300041 Timisoara, Romania
- Advanced Regional Research Center in Gastroenterology and Hepatology, “Victor Babeș” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | - Alexandru Popa
- Division of Gastroenterology and Hepatology, Department of Internal Medicine II, Victor Babeș University of Medicine and Pharmacy, 300041 Timisoara, Romania
- Advanced Regional Research Center in Gastroenterology and Hepatology, “Victor Babeș” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| | | | - Alina Popescu
- Division of Gastroenterology and Hepatology, Department of Internal Medicine II, Victor Babeș University of Medicine and Pharmacy, 300041 Timisoara, Romania
- Advanced Regional Research Center in Gastroenterology and Hepatology, “Victor Babeș” University of Medicine and Pharmacy, 300041 Timisoara, Romania
| |
Collapse
|
8
|
Düzkalır HG, Aydıner Ö, Söbü E, Dizman R. Clinical correlation of 2D shear wave elastography findings in children with type 1 diabetes mellitus without autoimmune thyroiditis. J Pediatr Endocrinol Metab 2023; 36:393-400. [PMID: 36883760 DOI: 10.1515/jpem-2023-0019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 02/20/2023] [Indexed: 03/09/2023]
Abstract
OBJECTIVES The aim of study was to evaluate the 2D shear wave sonoelastography (SWE) findings of the thyroid gland in children with type 1 diabetes mellitus (T1DM) with normal gray-scale findings and without thyroid autoimmunity (AIT) and obtain data that will be useful for the early detection of glandular involvement. METHODS The study included 46 T1DM patients (mean age: 11.28 ± 3.3 years) and 46 healthy children (mean age: 12.01 ± 3.8 years) as the control group. The thyroid gland mean elasticity value was obtained as kPa and compared in groups. A correlation was investigated between elasticity values and age at diabetes, serum free T4, thyroid stimulating hormone (TSH), anti-thyroglobulin, anti-tissue peroxidase, and hemoglobin A1c values. RESULTS No difference was found between T1DM patients and the control group in the thyroid 2D SWE evaluation (the median kPa value: 17.1 (10.2) in the study group and 16.8 (7.0) in the control group) (p=0.15). No significant correlation was found between 2D SWE kPa values and age at diagnosis, serum free T4, TSH, anti-thyroglobulin, anti-tissue peroxidase, and hemoglobin A1c levels in T1DM patients. CONCLUSIONS Our study showed that the elasticity of the thyroid gland in T1DM patients without AIT was not affected differently from that of the normal population. If 2D SWE is used in routine follow-up in T1DM patients before the development of AIT, we think that it will be useful in the early detection of thyroid gland affections and AIT, and long-term comprehensive studies in this direction will contribute to the literature.
Collapse
Affiliation(s)
| | - Ömer Aydıner
- Department of Radiology, Kartal Dr. Lütfi Kırdar City Hospital, Istanbul, Türkiye
| | - Elif Söbü
- Department of Pediatric Endocrinology, Kartal Dr. Lutfi Kirdar City Hospital, Istanbul, Türkiye
| | - Rıdvan Dizman
- Department of Radiology, Kartal Dr. Lütfi Kırdar City Hospital, Istanbul, Türkiye
| |
Collapse
|
9
|
Kojima H, Sofuni A, Sugimoto K, Tsuchiya T, Ishii K, Tanaka R, Tonozuka R, Yamamoto K, Hirakawa N, Itoi T. Efficacy of shear wave elastography for the diagnosis of chronic pancreatitis. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES 2023; 30:351-359. [PMID: 35918909 DOI: 10.1002/jhbp.1224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 07/01/2022] [Accepted: 07/27/2022] [Indexed: 11/10/2022]
Abstract
BACKGROUND/PURPOSE Shear wave elastography (SWE) is a clinical method used to evaluate liver hardness. In this study, we assessed its applicability in assessing the pancreas and its potential for diagnosing chronic pancreatitis. METHODS We performed SWE on 59 patients who underwent abdominal ultrasound, and measured the computed tomography (CT) values of the pancreas. Patients were classified as having a normal pancreas (NP), early chronic pancreatitis (ECP), or chronic pancreatitis (CP). SW elasticity (SWe), SW dispersion (SWd), and CT values between groups were analyzed. RESULTS SWe significantly differed between the CP and NP/ECP groups (NP vs CP; P = 0.001, ECP vs CP; P = 0.026,), while SWd showed a significant difference only between the NP and CP group (NP vs CP; P = 0.001). The CT values were significantly different between the CP and NP/ECP groups (NP vs CP; P = 0.0006, ECP vs CP; P = 0.0027). CONCLUSION Pancreatic SWE and CT values were helpful in the diagnosis of chronic pancreatitis. SWd may reveal status changes in ECP.
Collapse
Affiliation(s)
- Hiroyuki Kojima
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | - Atsushi Sofuni
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | | | | | - Kentaro Ishii
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | - Reina Tanaka
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | - Ryosuke Tonozuka
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | - Kenjiro Yamamoto
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | - Noriyuki Hirakawa
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| | - Takao Itoi
- Tokyo Medical University, Gastroenterology and Hepatology, Tokyo, Japan
| |
Collapse
|
10
|
Koca SB, Seber T. Can thyroid elastography with ultrasound be used to stage children with Hashimoto's thyroiditis? J Pediatr Endocrinol Metab 2023; 36:346-352. [PMID: 36843220 DOI: 10.1515/jpem-2022-0573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 02/07/2023] [Indexed: 02/28/2023]
Abstract
OBJECTIVES We aimed to evaluate the stiffness of the thyroid parenchyma with Shear wave elastography (SWE) in children with Hashimoto's thyroiditis (HT) and healthy controls. METHODS A total of 130 children with HT and 46 healthy controls were included in this study. The clinical and laboratory characteristics of the groups, thyroiditis stages in thyroid ultrasonography, and SWE scores which was obtained as kilopascal (kPa), were analysed. RESULTS We observed that SWE scores were significantly higher in children with HT compared to healthy controls, and SWE scores increased significantly in HT group, as the thyroiditis stage increased (p<0.001). Median, 1st (Q1) and 3rd (Q3) quartiles of SWE scores were as follows; healthy control: 7.4 kPa (6-10.6), stage 1 HT: 9.6 kPa (7.4-11.2), stage 2 HT: 15.2 kPa (10.8-19.9), stage 3 HT: 17.9 kPa (13.7-25.8), (p<0.001). Children with HT were divided into subgroups according to serum TSH and free T4 levels as euthyroid (103; 79.2% of children), euthyroid but subclinical TSH elevation (7; 5.4% of children), hypothyroidism (11; 8.5% of children) and hyperthyroidism (9; 6.9% of children). The SWE scores were significantly higher in children with hypothyroidism with HT compared to healthy controls 17.9 kPa (13.6-27.5) vs. 7.4 kPa (6-10.6), and in euthyroid children with HT compared to healthy controls 11.5 kPa (9.2-15.6) vs. 7.4 kPa (6-10.6), (p=0.006 and p<0.001, respectively). CONCLUSIONS The SWE scores increase as the thyroiditis stage increases in children with HT. There was no significant difference in SWE scores between stage 2 and stage 3 thyroiditis.
Collapse
Affiliation(s)
- Serkan Bilge Koca
- Department of Pediatrics, Division of Pediatric Endocrinology, Health Sciences University, Kayseri City Hospital, Kayseri, Türkiye
| | - Turgut Seber
- Department of Radiology, Division of Pediatric Radiology, Health Sciences University, Kayseri City Hospital, Kayseri, Türkiye
| |
Collapse
|
11
|
Bitkin EC, Toprak N. Diagnostic role of thyroid elastography in pediatric patients with Hashimoto's thyroiditis and Graves' disease: A prospective controlled study. Arch Pediatr 2023; 30:104-108. [PMID: 36509627 DOI: 10.1016/j.arcped.2022.11.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 05/13/2022] [Accepted: 11/11/2022] [Indexed: 12/14/2022]
Abstract
OBJECTIVE Hashimoto's thyroiditis and Graves' disease are autoimmune diseases of the thyroid gland, and both diseases are diagnosed with ultrasound findings and autoantibody height. However, ultrasound (US) findings may be normal in both diseases rarely. In some pediatric studies, it was reported that shear wave velocity values in autoimmune thyroiditis were significantly higher than normal thyroid parenchyma and it was recommended to be used as a diagnostic method. Our study will address the evaluation of patients with Hashimoto's thyroiditis and Graves' disease by thyroid elastography and the role of this method in diagnosis. MATERIALS AND METHODS 28 patients with Hashimoto's thyroiditis, 20 patients with Graves' disease and 40 healthy controls were enrolled in our study prospectively. Thyroid Elastography and US were applied to all patients. RESULTS In US, Hashimoto's thyroiditis had a hypoechoic echo pattern compared to graves' disease (p < 0.05). When shear wave velocity (SWV) value of children with Hashimoto's thyroiditis and Graves' disease were compared with the control group, thyroid tissue showed more stiffness in both disease groups (p = 0.001). When SWV values were compared between Hashimoto's thyroiditis and Graves' disease, there was no statistically significant difference (p = 0.73). CONCLUCION SWV values were found to be higher in children with Hashimoto's thyroiditis and Graves' disease compared to the control group and contributes to the diagnosis of these diseases. However, the elastography technique alone is not sufficient to differentiate. Hashimoto's thyroiditis and Graves' disease.
Collapse
Affiliation(s)
- Eda Celebi Bitkin
- Van Yüzüncü Yıl University Faculty of Medicine Department of Pediatrics, Division of Pediatric Endocrinology, Van, Turkey.
| | - Nursen Toprak
- Van Yüzüncü Yıl University Faculty of Medicine Department of Radiology, Van, Turkey
| |
Collapse
|
12
|
Decker T, Schnittka E, Stolzenberg L, Yalowitz J. Shear-Wave Elastography for the Diagnosis of Pediatric Hashimoto's Thyroiditis: A Systematic Review and Meta-Analysis. Cureus 2023; 15:e35490. [PMID: 37007310 PMCID: PMC10049949 DOI: 10.7759/cureus.35490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Accepted: 02/26/2023] [Indexed: 02/27/2023] Open
Abstract
Shear-wave elastography (SWE) has emerged as a novel ultrasonographic technique for the diagnosis of pediatric Hashimoto's Thyroiditis (HT). This systematic review and meta-analysis aim to summarize current evidence to determine the diagnostic value of SWE for HT. MEDLINE, a comprehensive search yielded five studies inclusive of 392 subjects. A meta-analysis comparing SWE values (kPa) between children with HT and healthy controls yielded a Cohen's d-value of 1.34 (CI 1.02-1.65), suggesting statistically significant differences in SWE values. Such evidence indicates that SWE may serve as a valuable tool in diagnosing HT in the pediatric population.
Collapse
Affiliation(s)
- Trevor Decker
- Radiology, Alabama College of Osteopathic Medicine, Dothan, USA
| | - Emma Schnittka
- Medicine, Alabama College of Osteopathic Medicine, Dothan, USA
| | | | | |
Collapse
|
13
|
Borysewicz-Sańczyk H, Sawicka B, Bossowski F, Dzięcioł J, Bossowski A. Elastographic Evaluation of Thyroid Nodules in Children and Adolescents with Hashimoto's Thyroiditis and Nodular Goiter with Reference to Cytological and/or Histopathological Diagnosis. J Clin Med 2022; 11:6339. [PMID: 36362565 PMCID: PMC9656584 DOI: 10.3390/jcm11216339] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Revised: 10/10/2022] [Accepted: 10/22/2022] [Indexed: 06/07/2025] Open
Abstract
There are data indicating the coexistence of papillary thyroid carcinoma and autoimmune thyroiditis (AIT) in children. The aim of the study was elastographic evaluation of thyroid nodules in children and adolescents with AIT and nodular goiter in relation to cytological and/or histopathological diagnosis. We examined 215 children (57 boys and 158 girls) with 261 thyroid nodules (143 non-AIT and 118 AIT). All study participants underwent a conventional ultrasound examination with elastography followed by fine needle aspiration biopsy (FNAB). Abnormal Strain Ratio (SR ≥ 5) was observed in 36 non-AIT nodules and 15 AIT nodules. Papillary thyroid carcinoma was diagnosed in 5 patients (2% of all investigated nodules). SR of malignant thyroid nodules was statistically higher in comparison to SR of benign nodules both in the group of non-AIT (6 ± 4 vs. 3.67 ± 2.62, p = 0.024) and AIT nodules (6.3 ± 0.01 vs. 2.92 ± 1.89, p = 0.047). Comparison of non-AIT and AIT benign nodules revealed that SR was higher in non-AIT nodules (3.67 ± 2.62 vs. 2.92 ± 1.89, p = 0.01). We observed a strong positive correlation (R = 1) between TSH concentration and SR ratio in the group of all malignant thyroid nodules. Autoimmune inflammatory process of the thyroid gland does not limit the use of elastography in the diagnosis of thyroid nodules in children.
Collapse
Affiliation(s)
- Hanna Borysewicz-Sańczyk
- Department of Paediatrics, Endocrinology, Diabetology with Cardiology Unit, Medical University of Bialystok, 15-089 Białystok, Poland
| | - Beata Sawicka
- Department of Paediatrics, Endocrinology, Diabetology with Cardiology Unit, Medical University of Bialystok, 15-089 Białystok, Poland
| | - Filip Bossowski
- Student Research Group, Department of Paediatrics, Endocrinology, Diabetology with Cardiology Unit, Medical University of Bialystok, 15-089 Białystok, Poland
| | - Janusz Dzięcioł
- Department of Human Anatomy, Medical University of Bialystok, 15-089 Białystok, Poland
| | - Artur Bossowski
- Department of Paediatrics, Endocrinology, Diabetology with Cardiology Unit, Medical University of Bialystok, 15-089 Białystok, Poland
| |
Collapse
|
14
|
Kamel SM, ElKhashab KM, Bhagat S, Elzayat WA. Shear wave elastography as a quantitative method for thyroid gland elasticity assessment in pediatrics patients with autoimmune-related thyroid disease, diagnostic utility and laboratory correlation. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2022. [DOI: 10.1186/s43055-022-00882-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Autoimmune thyroiditis (AIT) is the most common thyroid pathology in pediatric patients among which Hashimoto’s thyroiditis has the highest prevalence. Along with size, measuring mechano-acoustic tissue elasticity is evolving as an important parameter in the evaluation of diffuse thyroid pathology. This study aims to investigate the role of shear wave elastography (SWE) in the diagnosis of autoimmune thyroid disease (AITD) in the pediatric population and also compare the elasticity between them and healthy individuals.
Results
This case–control analytical study was carried out on 64 pediatric subjects ranging in age from 7 to 17 years. All the cases were diagnosed as AIT by anti-thyroid antibodies, and their thyroid function was evaluated by thyroid hormones. We performed thyroid Ultrasonography and Shear wave elastography. Patients with AIT had significantly higher elasticity values (35.6 kPa, IQR 8.43–103.7 kPa) than the control group (9.35 kPa, IQR 5.73–13.21 kPa). There was no correlation of elasticity values of thyroid gland in patients with AIT with autoantibodies and thyroid function test, respectively. The cutoff value for elasticity was 12.317 kPa with sensitivity and specificity of 96.9% and 100%, respectively.
Conclusions
SWE is a highly sensitive imaging method integrating routine ultrasonography in the diagnosis of AITD which estimates the extent of fibrosis in numerical value.
Collapse
|
15
|
Burakgazi G, Ilhan G, Ozcan O, Dirican E. Ultrasonographic shear wave elastography of the thyroid in patients with sickle cell anemia. ASIAN BIOMED 2022; 16:137-143. [PMID: 37551381 PMCID: PMC10321170 DOI: 10.2478/abm-2022-0017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Background Although thyroid radiology has been conducted in patients with sickle cell anemia (SCA), to our knowledge, there is no report of thyroid gland assessment using ultrasonographic shear wave elastography (US-SWE). Objectives To determine values for ultrasonographic US-SWE of the thyroid in patients with SCA and correlations between thyroid elasticity and biochemical variables used to evaluate thyroid function. Methods Prospective case-control observational study of 36 patients with SCA and 33 healthy volunteer controls. US-SWE measurements of thyroid gland parenchyma and biochemical parameters of the participants were obtained and compared, and the diagnostic accuracy of elasticity was determined. Results The thyroid volume was smaller in patients with SCA than that in controls (P = 0.001). Compared with the controls, the patients with SCA had significantly lower serum levels of free triiodothyronine (fT3) (P = 0.004) and thyroglobulin (Tg) (P = 0.001) and significantly higher levels of thyroid-stimulating hormone (P = 0.028). Thyroid stiffness was significantly higher in the left lobe (LL) of the patients with SCA than in the controls (P = 0.003). In the patients with SCA, we found a significant correlation between right lobe (RL) and LL stiffness and serum levels of Tg (RL [r = -0.439] and LL [r = -0.484]; P = 0.021) and fT3 (RL [r = -0.463] and LL [r = -0.386]; P = 0.012). Receiver operating characteristic (ROC) curve analysis of thyroid elasticity that represented a diagnosis of SCA found a cutoff of >7.31 kPa, a sensitivity of 52.0%, and a specificity of 72.0% for the RL (P = 0.316, area under the curve [AUC] 0.570), and a cutoff of >8.06 kPa, a sensitivity of 58.0%, and a specificity of 84.0% for the LL (P = 0.011, AUC 0.680). Conclusions US-SWE can be used to follow up thyroid changes in patients with SCA.
Collapse
Affiliation(s)
- Gulen Burakgazi
- Department of Radiology, Faculty of Medicine, Mustafa Kemal University, Antakya, Hatay31100, Turkey
| | - Gul Ilhan
- Department of Hematology, Faculty of Medicine, Mustafa Kemal University, Antakya, Hatay31100, Turkey
| | - Oguzhan Ozcan
- Department of Biochemistry, Faculty of Medicine, Mustafa Kemal University, Antakya, Hatay31100, Turkey
| | - Emre Dirican
- Department of Biostatistics, Faculty of Medicine, Mustafa Kemal University, Antakya, Hatay31100, Turkey
| |
Collapse
|
16
|
Li L, Zhang A, Chen D, Taragin BH, Luo X. Preliminary study of sound touch elastography in diffuse thyroid disease in children. Front Pediatr 2022; 10:964413. [PMID: 36275048 PMCID: PMC9582431 DOI: 10.3389/fped.2022.964413] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 09/13/2022] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVE The purpose of this study was to evaluate the use of sound touch elastography (STE) in conjunction with conventional ultrasound in the differential diagnosis of diffuse thyroid disease (DTD) and normal thyroid in children. METHODS Studies performed on 62 children with DTD and 30 normal volunteers were reviewed. Standard gray scale ultrasound, Doppler ultrasound and STE of the examinees, and the serum test results of children with DTD were collected, analyzed and compared. RESULTS The STE-Mean values in the Graves' disease (GD) group, Hashimoto's thyroiditis (HT) group, and normal control group, respectively, were 19.35 ± 5.00 kPa, 19.43 ± 6.06 kPa, and 11.24 ± 1.99 kPa. With an area under the ROC curve (AUC) of 0.945, STE-Mean values differentiated DTD from normal children. The peak systolic velocity (PSV) of the superior thyroid artery separated DTD from normal children and AUC from children with GD and HT, respectively, and was 0.992 and 0.864. The PSV of superior thyroid artery revealed a somewhat favorable connection with FT3 and FT4. CONCLUSION The STE results revealed that thyroid stiffness was higher in children with DTD than in normal children, but further differentiation into GD and HT subgroups lacked specificity, and the superior thyroid artery flow velocity might be a good supplement to distinguish both.
Collapse
Affiliation(s)
- Lin Li
- Department of Ultrasonography, Suining Central Hospital, Suining, China
| | - Aimei Zhang
- Department of Ultrasonography, Suining Central Hospital, Suining, China
| | - Dan Chen
- Department of Ultrasonography, Suining Central Hospital, Suining, China
| | - Benjamin H Taragin
- Department of Radiology, Samson Assuta Ashdod University Hospital, Ashdod, Israel
| | - Xiaoyong Luo
- Department of Ultrasonography, Suining Central Hospital, Suining, China
| |
Collapse
|
17
|
Liang S, Gao N, Bian D, Zhai Q, Yang P, Huang K. Clinical value of contrast-enhanced ultrasonography in focal hypoechogenic lesions of thyroid. Eur Arch Otorhinolaryngol 2021; 279:2077-2082. [PMID: 34274997 DOI: 10.1007/s00405-021-06982-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/05/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The objectives of this study were to analyze the accuracy of contrast-enhanced ultrasonography (CE-US) in diagnosing focal hypoechogenic lesions of the thyroid (FHLT), and to explore the clinical value of CE-US in the diagnosis of FHLT. METHODS Patients undergoing CE-US and ultrasound-guided fine needle aspiration (US-FNA) of FHLT at First Hospital of China Medical University between January 2017 and December 2018 were selected for the study; this included patients with papillary thyroid carcinoma (PTC), subacute thyroiditis (SAT) and focal Hashimoto thyroiditis (FHT). All patients underwent color Doppler ultrasonography (CD-US) after which thyroid image reporting and data system (TI-RADS) grading were done. Then, each patient underwent CE-US and US-FNA. The results of the CE-US were analyzed using descriptive statistics. The cytopathological results from the US-FNAs were the gold standard used to confirm the diagnoses. RESULTS A total of 56 patients were selected for the study. In the PTC group (n = 16), grading was as follows: TI-RADS4a, n = 3; TI-RADS4b, n = 12; and TI-RADS4c, n = 1. More patients with PTC showed heterogeneous hypoenhancement (n = 15) than heterogeneous isoenhancement (n = 1) on CE-US. In the SAT group (n = 24), grading was as follows: TI-RADS3, n = 1; TI-RADS4a, n = 18; TI-RADS4b, n = 5. Fewer patients with SAT showed heterogeneous hypoenhancement (n = 2) than heterogeneous isoenhancement (n = 22) on CE-US. In the FHT group (n = 16), grading was as follows: TI-RADS3, n = 1; TI-RADS4a, n = 11; TI-RADS4b, n = 4. Of those in the FHT group, one patient showed heterogeneous isoenhancement, one patient showed heterogeneous hypoenhancement, and 14 showed uniform isoenhancement on CE-US. The diagnostic accuracy of CD-US alone differed significantly from that of CD-US + CE-US (p < 0.05). CONCLUSION CE-US has a high diagnostic accuracy for FHLT and can be used to identify PTC, SAT, and FHT.
Collapse
Affiliation(s)
- Songnian Liang
- Department of Radiology, The First Affiliated Hospital of China Medical University, Shenyang, Liaoning, People's Republic of China
| | - Ningning Gao
- Department of Ultrasonic Diagnosis, Liaoning Province Cancer Hospital and Institute, Shenyang, Liaoning, People's Republic of China
| | - Donglin Bian
- Department of Ultrasonic Diagnosis, The First Affiliated Hospital of China Medical University, Nanjingbei Street 155#, Shenyang, Liaoning, People's Republic of China
| | - Qixi Zhai
- Department of Ultrasonic Diagnosis, The First Affiliated Hospital of China Medical University, Nanjingbei Street 155#, Shenyang, Liaoning, People's Republic of China
| | - Puxu Yang
- Department of Ultrasonic Diagnosis, The First Affiliated Hospital of China Medical University, Nanjingbei Street 155#, Shenyang, Liaoning, People's Republic of China
| | - Kun Huang
- Department of Ultrasonic Diagnosis, The First Affiliated Hospital of China Medical University, Nanjingbei Street 155#, Shenyang, Liaoning, People's Republic of China.
| |
Collapse
|
18
|
Fu Z, Zhang J, Lu Y, Wang S, Mo X, He Y, Wang C, Chen H. Clinical Applications of Superb Microvascular Imaging in the Superficial Tissues and Organs: A Systematic Review. Acad Radiol 2021; 28:694-703. [PMID: 32418782 DOI: 10.1016/j.acra.2020.03.032] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 03/13/2020] [Accepted: 03/20/2020] [Indexed: 12/12/2022]
Abstract
Superb microvascular imaging (SMI) is an innovative Doppler technique for vascular examination. It uses an intelligent algorithm that efficiently separates low-speed flow signals from motion artifacts so that it can assess microvessels and the vessel distribution in detail. This article reviews the clinical applications of SMI in the disorders of superficial tissues and organs including thyroid nodules, breast tumors and lymph node diseases etc. More information of diseases that are closely associated with angiogenesis can be shown by SMI than other noninvasive examinations. Although some limitations exist, this safe and convenient technique is becoming acceptable and would play a more important role in disease diagnosis and therapeutic responses evaluation.
Collapse
Affiliation(s)
- Zehui Fu
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China
| | - Jian Zhang
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China
| | - Yejun Lu
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China
| | - Siqi Wang
- Department of Radiology, The Third Affiliated Hospital of Soochow University, Changzhou 213003, China
| | - Xiaomin Mo
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China
| | - Ye He
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China
| | - Chong Wang
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China
| | - Hui Chen
- Department of Ultrasound, The Third Affiliated Hospital of Soochow University, No.185, Juqian Street, Changzhou 213003, China.
| |
Collapse
|
19
|
Andaç Baltacıoğlu N, Mantar F, Soydemir E. Evaluation of the relationship between shear wave elastography measurements with laboratory and Doppler US parameters in patients with adult Hashimoto’s thyroiditis. Turk J Med Sci 2021; 51:778-786. [PMID: 33244946 PMCID: PMC8203158 DOI: 10.3906/sag-2008-210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Accepted: 11/26/2020] [Indexed: 11/03/2022] Open
Abstract
Background/aim Hashimoto thyroiditis (HT) is an autoimmune disease that leads to tissue stiffening secondary to lymphocyte infiltration of the thyroid gland. Gray-scale ultrasound (US) is widely used in its diagnosis. Numerous studies have been conducted comparing elastography findings of HT with tissue stiffness and immunoreactivity levels. This study aims to reveal the relationship between shear wave elastography (SWE) and Doppler parameters in patients with HT. Materials and methods The study group consisted of 45 patients diagnosed with HT, and 20 control patients without thyroid pathology. Thyroid-stimulating hormone (TSH) and antithyroid peroxidase (TPO) values were examined in patients with HT. Thyroid gland volume and echo patterns were evaluated in the gray-scale US. Doppler measurements –peak systolic velocity (Vmax), end-diastolic velocity (Vmin), pulsatility index (PI), resistivity index (RI)– from the superior thyroidal artery and SWE measurements were taken from both thyroid lobes. Results The mean age of men and women in the HT group was 44.8 and 43.4 years. The mean TSH value (normal value: 0.3–4.2 uIU/ mL) was 3.90 ± 6.6 uIU/mL, and the anti-TPO value (normal value: < 35 IU/mL) was 235.47 ± 271.12 IU/mL. The average thyroid gland volume was 10.12 ± 2.71 mL in the HT group and 6.62 ± 2.11 mL in the control group (P = 0.034). HT group mean Vmax, mean Vmin, mean PI and RI values were significantly lower compared to normal subjects (P = 0.022, P = 0.026, P = 0.042, P = 0.046, respectively). The average SWE value of the thyroid gland was 24.56 ± 18.04 kPa in the experimental group and 7.34 ± 3.54 (P < 0.05) in the control group. Conclusion A positive correlation was found between PI and RI values and elastography values. An increase in SWE and decreases in Vmax and Vmin were found as high diagnostic value for HT.
Collapse
Affiliation(s)
| | - Ferhan Mantar
- Department of Endocrinology, VKV American Hospital, İstanbul, Türkiye
| | - Efe Soydemir
- Department of Radiology, Ministry of Health-Marmara University Pendik Education and Research Hospital, İstanbul, Türkiye
| |
Collapse
|
20
|
Kılınçer A, Durmaz MS, Baldane S, Kıraç CO, Cebeci H, Koplay M. Evaluation of the Stiffness of Thyroid Parenchyma With Shear Wave Elastography Using a Free-Region of Interest Technique in Graves Disease. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:471-480. [PMID: 32767605 DOI: 10.1002/jum.15422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 05/31/2020] [Accepted: 06/24/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES The first aim was to evaluate the stiffness of thyroid parenchyma with shear wave elastography (SWE) in patients with Graves disease (GD) and compare the elastographic values with those of asymptomatic volunteers. The second aim was to evaluate whether there was a correlation between SWE values and grayscale ultrasound (US) and laboratory parameters. METHODS In this prospective study, the thyroid gland parenchyma of 50 patients whose clinical and laboratory findings were indicative for GD and 54 asymptomatic participants with normal laboratory values was examined by SWE. Grayscale US images of the thyroid and submandibular gland were recorded. The volume of the thyroid gland was measured. Elastographic measurements were performed with a free region of interest. The quantitative SWE values (meters per second and kilopascals) of the patient and control groups were compared. A correlation analysis between the SWE values and grayscale US and laboratory parameters was performed. RESULTS The median (range) SWE values of the thyroid gland in patients with GD were significantly higher than those of the control group [17.34 (12.58-56.15) versus 12.05 (7.72-23.67) kPa and 2.28 (1.83-4.12) versus 1.92 (1.55-2.61) m/s; P < .001 for both comparisons]. When 14.5 kPa or 2.115 m/s was designated as the cutoff value, GD could be diagnosed with a high sensitivity and specificity. We showed a negative weak correlation between the SWE values and parenchymal echogenicity in the GD group. CONCLUSIONS Shear wave elastography can be used as an effective imaging method with high sensitivity and specificity rates in the diagnosis of GD.
Collapse
Affiliation(s)
- Abidin Kılınçer
- Department of Radiology, Selçuk University Faculty of Medicine, Konya, Turkey
| | - Mehmet Sedat Durmaz
- Department of Radiology, Selçuk University Faculty of Medicine, Konya, Turkey
| | - Süleyman Baldane
- Department of Internal Medicine, Selçuk University Faculty of Medicine, Konya, Turkey
| | - Cem Onur Kıraç
- Department of Internal Medicine, Selçuk University Faculty of Medicine, Konya, Turkey
| | - Hakan Cebeci
- Department of Radiology, Selçuk University Faculty of Medicine, Konya, Turkey
| | - Mustafa Koplay
- Department of Radiology, Selçuk University Faculty of Medicine, Konya, Turkey
| |
Collapse
|
21
|
Shear-Wave Elastography-Diagnostic Value in Children with Chronic Autoimmune Thyroiditis. Diagnostics (Basel) 2021; 11:diagnostics11020248. [PMID: 33562689 PMCID: PMC7915688 DOI: 10.3390/diagnostics11020248] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 02/01/2021] [Accepted: 02/02/2021] [Indexed: 11/17/2022] Open
Abstract
Chronic autoimmune thyroiditis (CAT) is the most common thyroid disorder in the pediatric population. Ultrasound evaluation may suggest the diagnosis. Additionally, shear-wave elastography (SWE) proved to be a valuable additional diagnosis tool in adults with CAT by assessing thyroid stiffness (TS). This study aims to assess its use also in detecting children with CAT. The study group consisted of 50 children with confirmed diagnosis of CAT, who were compared to the control group, consisting of 50 children with no thyroid pathology and with an adult group of 50 subjects with CAT. The evaluation included, besides bioimmunochemical evaluation, also thyroid ultrasound evaluation and elastography measurements in the same session (Aixplorer Mach 30, Supersonic imagine, France). The mean TS values were significantly lower for children in the CAT group compared to adults with CAT (15.51 ± 4.76 kPa vs. 20.96 ± 6.31 kPa; p < 0.0001) and higher compared to the healthy aged matched controls (15.51 ± 4.76 kPa vs. 10.41 ± 2.01 kPa; p < 0.0001). SWE elastography definitely seems a promising technique in the evaluation of children with autoimmune thyroid pathology.
Collapse
|
22
|
Suzuki H, Kawashima H, Ohno E, Ishikawa T, Hashimoto S, Nakamura M, Miyahara R, Ishigami M, Hirooka Y, Fujishiro M. What is the role of measuring shear wave dispersion using shear wave elastography in pancreatic parenchyma? J Med Ultrason (2001) 2020; 47:575-581. [PMID: 32602019 DOI: 10.1007/s10396-020-01033-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Accepted: 05/23/2020] [Indexed: 12/17/2022]
Abstract
PURPOSE Shear wave elastography (SWE) using transabdominal ultrasonography (US) is widely used for diagnosis of tissue stiffness. Ultrasound shear wave dispersion (SWD) enables evaluation of tissue viscosity using SWE. The objective of this study was to investigate the reliability and clinical significance of SWD in pancreatic screening. METHODS SWE and SWD were measured in 76 patients examined by US in pancreatic screenings performed between November 2017 and November 2018. The median pancreatic elastic modulus (PEM) and dispersion slope were obtained from at least five measurements. The reproducibility of these values and their correlations with patient characteristics, pancreatic echogenicity, and the pancreas-to-spleen attenuation ratio (P/S) on plain CT, which is associated with fatty change in pancreatic parenchyma, were investigated retrospectively. RESULTS The median PEM and dispersion slope were 7.4 kPa and 15.7 (m/sec)/kHz, respectively, and both values had high intraclass correlation coefficients, showing high reproducibility (ρ = 0.869 and ρ = 0.867, respectively). The interquartile range/median value of PEM and dispersion slope were 0.36 and 0.28, respectively. PEM had a positive correlation with age (rs = 0.348, p = 0.002), and dispersion slope was positively correlated with age (rs = 0.278, p = 0.016) and BMI (rs = 0.397, p < 0.001). The hyperechoic pancreas had significantly higher PEM (6.6 vs. 7.8 kPa, p = 0.037) and dispersion slope (13.2 vs. 16.3 (m/sec)/kHz, p < 0.001). On plain CT performed in 50 patients, the P/S was not correlated with PEM (rs = - 0.180, p = 0.221), but was inversely correlated with dispersion slope (rs = - 0.338, p = 0.019). CONCLUSION Measurement of SWD in pancreatic screening was highly reproducible and may permit objective evaluation of fatty change of the pancreas.
Collapse
Affiliation(s)
- Hirotaka Suzuki
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Hiroki Kawashima
- Department of Endoscopy, Nagoya University Hospital, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan.
| | - Eizaburo Ohno
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Takuya Ishikawa
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Senju Hashimoto
- Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, 470-1192, Japan
| | - Masanao Nakamura
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Ryoji Miyahara
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Masatoshi Ishigami
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Yoshiki Hirooka
- Department of Liver, Biliary Tract and Pancreas Diseases, Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, 470-1192, Japan
| | - Mitsuhiro Fujishiro
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, 65 Tsuruma-Cho, Showa-ku, Nagoya, 466-8550, Japan
| |
Collapse
|
23
|
Görgülü O, Görgülü FF, Koç AS. Can the unnecessary operations for suspected thyroid nodules be avoided by the combined use of the strain ratio and elastography score? Braz J Otorhinolaryngol 2020; 87:338-345. [PMID: 32653346 PMCID: PMC9422504 DOI: 10.1016/j.bjorl.2020.05.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 05/06/2020] [Accepted: 05/18/2020] [Indexed: 11/25/2022] Open
Abstract
Introduction Only 5%–15% of thyroid surgical specimens are reported as malignant. Most of the operations are performed due to suspicion of malignancy as a result of fine needle aspiration biopsy but invasiveness, non-diagnostic results and potential repeat biopsies are disadvantages of fine needle aspiration biopsy. Objective The aim of this study was to investigate the effectiveness of simultaneously using both the strain ratio and elasticity score in the differential diagnosis of thyroid nodules, as well as to assess the compatibility of these two methods. Methods A total of 144 nodules were included in the study. The final histopathologic diagnosis was used as the reference standard. The area under the curve sensitivity, specificity, and cut-off values of the strain ratio and elasticity score were determined using receiver operating characteristic curve analysis. The compatibility and comparison of strain ratio and elasticity score were also performed. Results Twenty eight nodules (19.4%) were malignant. The strain ratio and elasticity score results were found to be significantly successful in predicting thyroid malignancy (p < 0.001 for both). Moreover, the area under the curve for the strain ratio and elasticity score were found to be 0.944 and 0.960, respectively. The diagnostic accuracy of the elasticity score was found to be superior to that of the strain ratio, but this difference was not statistically significant (p = 0.456). When the compatibility of the strain ratio and elasticity score was examined, the two evaluations were revealed to be statistically consistent with each other (Kappa = 0.767; p < 0.001). When the strain ratio and the elasticity score were used together, the specificity of capturing the correct diagnosis increased from 84.5% to 93.1%. Conclusion When the strain ratio an elasticity score were used together for the differential diagnosis of thyroid nodules, more accurate results were obtained. Thus, combining both methods may be a promising alternative to fine needle aspiration biopsy in order to prevent unnecessary surgical interventions for suspected thyroid nodules.
Collapse
Affiliation(s)
- Orhan Görgülü
- University of Health Sciences, Adana Health Practice and Research Center, Department of Otorhinolaryngology, Adana, Turkey.
| | - Feride Fatma Görgülü
- University of Health Sciences, Adana Health Practice and Research Center, Radiology Department, Adana, Turkey
| | - Ayşe Selcan Koç
- University of Health Sciences, Adana Health Practice and Research Center, Radiology Department, Adana, Turkey
| |
Collapse
|
24
|
Sedlackova Z, Herman J, Furst T, Salzman R, Vachutka J, Herman M. Shear wave elastography in diffuse thyroid disease. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2020; 165:152-156. [PMID: 32394978 DOI: 10.5507/bp.2020.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 04/20/2020] [Indexed: 11/23/2022] Open
Abstract
AIM Our aim was to examine the contribution of shear wave elastography to ultrasonographic assessment in diffuse thyroid disease, specifically to evaluate the stiffness of the thyroid gland in diffuse thyroid disease and compare it with healthy controls. METHODS A total of 46 patients with diffuse thyroid disease were examined clinically, by conventional ultrasound, and shear wave elastography. The conventional ultrasound parameters followed were: volume, margin quality, presence of nodules, and vascularisation. We measured the mean, minimum, and maximum stiffnesses by shear wave elastography. Results were correlated with values in 128 healthy subjects. RESULTS Patients with diffuse thyroid disease had significantly higher mean and maximal stiffnesses of the thyroid gland: 12.5 ± 5 kPa and 35.3 ± 12.8 kPa, respectively, and lower minimal stiffness: 0.5 ± 0.6 kPa than the healthy control group with mean, maximal, and minimal values of 9.5 ± 3.6 kPa, 22.5 ± 7.3 kPa, and 2.2 ± 2.1 kPa (P<0.001). Stiffness values were positively correlated with BMI and volume of the thyroid; they did not correlate with margin quality, presence of nodules nor vascularisation. Compared with healthy volunteers, thyroid glands of patients with diffuse thyroid disease had a blurred margin more frequently and the amount of nodules and vascularisation were higher. Patients with Graves-Basedow disease did not have significantly different mean, maximal, nor minimal stiffnesses than those with thyroiditis. CONCLUSION Both mean and maximal stiffness of the thyroid gland are significantly higher in diffuse thyroid disease than in the healthy population, while minimal stiffness is lower.
Collapse
Affiliation(s)
- Zuzana Sedlackova
- Department of Radiology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital, Olomouc, Czech Republic
| | - Jan Herman
- Department of Otorhinolaryngology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital, Olomouc, Czech Republic
| | - Tomas Furst
- Department of Radiology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital, Olomouc, Czech Republic
| | - Richard Salzman
- Department of Otorhinolaryngology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital, Olomouc, Czech Republic
| | - Jaromir Vachutka
- Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University, Olomouc, Czech Republic
| | - Miroslav Herman
- Department of Radiology, Faculty of Medicine and Dentistry, Palacky University Olomouc and University Hospital, Olomouc, Czech Republic
| |
Collapse
|
25
|
Assessment of thyroid gland elasticity with shear-wave elastography in Hashimoto's thyroiditis patients. J Ultrasound 2020; 23:543-551. [PMID: 32185701 DOI: 10.1007/s40477-020-00437-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Accepted: 02/15/2020] [Indexed: 12/17/2022] Open
Abstract
PURPOSE We aimed to investigate the use and effectiveness of Shear-Wave Elastography (SWE) in Hashimoto's Thyroiditis (HT) diagnosis and compare the SWE values in HT patients with asymptomatic volunteers. METHODS The thyroid gland parenchyma of 74 patients whose clinical and laboratory findings and ultrasonography (US) features were indicative of HT and 75 healthy, asymptomatic participants with normal laboratory values were examined using SWE. Their thyroid parenchymal echoes and thyroid gland volume were measured using B-mode US examination. Elastographic measurements were made by plotting the boundaries of thyroid gland by hand, using Free Region of Interest (ROI). The quantitative SWE values [meters/second (m/s) and kilopascal (kPa)] were compared betweent the patients and the controls. The correlation analyses between the SWE measurements and the autoantibodies [Anti-thyroid peroxidase antibody (TPOAbs) and anti-thyroglobulin antibodies (TgAbs)], thyroid-stimulating hormone (TSH), freetriiodothyronine (fT3), free-thyroxine (fT4), and thyroglobulin levels were performed. RESULTS The mean thyroid SWE measurement values of HT group were significantly higher than the asymptomatic group (p < 0.001). This study proposes 29.45 kPa or 2.77 m/s as a sensitive-spesific cut-off value for HT. We revealed significant positive association between SWE values and TgAb levels, gland volume, TgAb, TPOAb levels, and a significant negative association between SWE and echogenicity (p < 0.001). CONCLUSION In the assessment of HT, SWE is a highly sensitive imaging method to estimate the degree of fibrosis and to provide objective numerical values.
Collapse
|
26
|
Li A, Peng XJ, Ma Q, Dong Y, Mao CL, Hu Y. Diagnostic performance of conventional ultrasound and quantitative and qualitative real-time shear wave elastography in musculoskeletal soft tissue tumors. J Orthop Surg Res 2020; 15:103. [PMID: 32160894 PMCID: PMC7066781 DOI: 10.1186/s13018-020-01620-x] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Accepted: 03/03/2020] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND To explore the feasibility to identify malignant musculoskeletal soft tissue tumors using real-time shear wave elastography (rtSWE). METHODS One hundred fifteen musculoskeletal soft tissue tumors in 92 consecutive patients were examined using both conventional ultrasonography (US) and rtSWE. For each patient, the rtSWE parameters including maximum elasticity (Emax), mean elasticity (Emean), minimum elasticity (Emin), standard deviation of the elasticity (Esd), and rtSWE image pattern were obtained. Eighty-one histopathologically confirmed tumors from 73 patients were subjected to analysis. RESULTS The 81 lesions included in the study were histopathologically classified as malignant (n = 21) or benign (n = 60). The statistically significant differences between benign and malignant lesions were found in conventional US characters including size, depth, margin, echogenicity, mass texture, and power Doppler signal. Meanwhile, the significant differences were also found in quantitative rtSWE findings including Emax, Emean, Emin, and Esd values and in qualitative rtSWE parameter named rtSWE image pattern. Multivariate analysis showed that infiltrative margin (OR, 4.470), and size (OR, 1.046) were independent predictors for malignancy in US findings, while Esd value (OR, 9.047) was independent predictors for malignancy in quantitative rtSWE parameters. Areas under the ROC curve (Azs) for US features, Esd value, and rtSWE image pattern were 0.851, 0.795, and 0.792, respectively. CONCLUSIONS Conventional US and quantitative and qualitative rtSWE parameters are useful for malignancy prediction of musculoskeletal soft tissue tumors. rtSWE can be used to supplement conventional US to diagnose musculoskeletal soft tissue tumors.
Collapse
Affiliation(s)
- Ao Li
- Department of Ultrasound, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China
| | - Xiao-Jing Peng
- Department of Ultrasound, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China
| | - Qian Ma
- Department of Ultrasound, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China
| | - Ye Dong
- Department of Ultrasound, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China
| | - Cui-Lian Mao
- Department of Ultrasound, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China
| | - Yu Hu
- Department of Ultrasound, the First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China.
| |
Collapse
|
27
|
Quantitative Assessment of Thyroid Glands in Healthy Children With Shear Wave Elastography. Ultrasound Q 2020; 35:297-300. [PMID: 30724864 DOI: 10.1097/ruq.0000000000000426] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The local shear wave speed (in meters per second) and Young modulus (in kilopascals) of normal thyroid glands were defined in healthy children to determine reference values.This prospective study assessed 107 pediatric cases (age interval, 3-17 years; mean, 9.37 ± 3.68 years), including 52 boys and 55 girls. The study group included children without thyroid gland disease (autoimmune, infectious, or neoplastic). Data about the sex, age, weight, height, and body mass index (BMI) of the subjects were recorded for all subjects. Elasticity values were measured from 3 different sites in both thyroid lobes and averaged.Median values for elasticity and shear wave velocity measured in bilateral thyroid lobes were 6.38 ± 1.97 kPa (range, 3.00-12.5 kPa) and 1.45 ± 0.21 m/s (range, 1.03-2.04 m/s) on the right and 8.81 ± 3.00 kPa (range, 3.80-22.6 kPa) and 1.69 ± 0.26 m/s (range, 1.13-2.68 m/s) on the left. There was no significant difference between the elasticity values for the right and left thyroid lobes between boys and girls. There was a positive correlation between right thyroid lobe mean elasticity (in kilopascals) and shear wave velocity (in meters per second) values with age, BMI, and right thyroid lobe volume in the whole group. No significant correlation was found between left thyroid lobe mean elasticity (in kilopascals) and shear wave velocity (in meters per second) values with age, BMI, and left thyroid lobe volume in the study population.This study determined mean elasticity and shear wave velocity values for thyroid gland in healthy children. This information can be used as a baseline for the investigation of thyroid diseases.
Collapse
|
28
|
Quantitative Assessment of Thyroid Gland Vascularization With Vascularization Index Using Color Superb Microvascular Imaging in Pediatric Patients With Hashimoto Thyroiditis. Ultrasound Q 2019; 35:281-289. [DOI: 10.1097/ruq.0000000000000430] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
29
|
Hefeda MM. Value of the New Elastography Technique using Acoustic Radiation Force Impulse in Differentiation between Hashimoto's Thyroiditis and Graves' Disease. J Clin Imaging Sci 2019; 9:17. [PMID: 31448168 PMCID: PMC6702860 DOI: 10.25259/jcis-22-2019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Accepted: 03/27/2019] [Indexed: 01/05/2023] Open
Abstract
Background and Aim: This study was performed to evaluate the role and accuracy of shear wave elastography in the differentiation between Graves’ disease (GD) and Hashimoto’s thyroiditis (HT), in comparison with the B-mode ultrasound and color Doppler ultrasound. Materials and Methods: This study was non-randomized prospective study. The study included 30 patients with GD, 65 patients with HT, and 35 patients with normal thyroid glands. Assessment of ultrasonographic criteria, color Doppler flow pattern, and shear patterns differed significantly between the control group and the group of diffuse thyroid disease (P < 0.001). The most specific sign for diagnosing HT was nodularity (97.87%), and the most sensitive sign was coarse echotexture (81.54%). Color Doppler flow (CDF) showed sensitivity of 91.8%, specificity of 56.92%, positive predictive value of 52.54%, negative predictive value of 92.5%, and diagnostic accuracy of 68.69% in the differentiation between GD and HT. The mean shear wave velocity (SWV) was 2.61 ± 0.32 m/s in the GD group (range: 2.1–3.21 m/s), 2.85 ± 0.52 m/s in the HT group (range: 2.31–3.82 m/s), and 1.75 ± 0.37 m/s in the control group (range: 1.24–2.36 m/s). The mean SWVs in the GD and HT groups were significantly higher than that in the control group (P < 0.001). The mean SWV in the HT group was higher than that in the GD group (P = 0.03). Conclusion: Quantitative and qualitative SWE is useful for diagnosing diffuse thyroid disease and evaluating the degree of fibrosis in autoimmune thyroiditis. However, acoustic radiation force impulse techniques cannot differentiate between HT and GD reliably.
Collapse
|
30
|
Adaletli I, Bayramoglu Z, Caliskan E, Yilmaz R, Akyol Sari ZN, Bas F, Kardelen AD, Poyrazoglu S, Darendeliler F. Multi-parametric Ultrasound Evaluation of Pediatric Thyroid Dyshormonogenesis. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1644-1653. [PMID: 31031038 DOI: 10.1016/j.ultrasmedbio.2019.03.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Revised: 02/01/2019] [Accepted: 03/05/2019] [Indexed: 06/09/2023]
Abstract
The aim of this study was to assess the diagnostic contribution of gray-scale ultrasonography, color Doppler, superb microvascular imaging and shear wave elastography in thyroid dyshormonogenesis (TD). From October 2017 to February 2018, the prospective study included 31 patients (13.6 y; 11-14 y) diagnosed with TD based on thyroid scintigraphy and perchlorate discharge tests and 40 healthy pediatric volunteers (12.8 y; 10-16 y). Median resistive indices (RIs), peak systolic and end-diastolic velocities, vascularity indices (VIs) via superb microvascular imaging and shear wave elastography parameters were evaluated. Median VI values were significantly higher and median RI values were significantly lower in the study group than the control group. No significant difference was found between shear wave elastography parameters of the TD and control group. VI was significantly correlated with median total thyroid gland volumes (p = 0.002, r = 0.28), medication dosage (p = 0.03, r = 0.48) and 2-h radioactive iodine uptake values (p = 0.008, r = 0.57). VI is a clinically significant and novel parameter useful for diagnosing TD.
Collapse
Affiliation(s)
- Ibrahim Adaletli
- Istanbul Medical Faculty, Radiology Department, Istanbul University, Istanbul, Turkey
| | - Zuhal Bayramoglu
- Istanbul Medical Faculty, Radiology Department, Istanbul University, Istanbul, Turkey.
| | - Emine Caliskan
- Radiology Department, Seyhan State Hospital, Adana, Turkey
| | - Ravza Yilmaz
- Istanbul Medical Faculty, Radiology Department, Istanbul University, Istanbul, Turkey
| | - Zeynep Nur Akyol Sari
- Istanbul Medical Faculty, Radiology Department, Istanbul University, Istanbul, Turkey
| | - Firdevs Bas
- Istanbul Medical Faculty, Pediatric Endocrinology Department, Istanbul University, Istanbul, Turkey
| | - Aslı Derya Kardelen
- Istanbul Medical Faculty, Pediatric Endocrinology Department, Istanbul University, Istanbul, Turkey
| | - Sukran Poyrazoglu
- Istanbul Medical Faculty, Pediatric Endocrinology Department, Istanbul University, Istanbul, Turkey
| | - Feyza Darendeliler
- Istanbul Medical Faculty, Pediatric Endocrinology Department, Istanbul University, Istanbul, Turkey
| |
Collapse
|
31
|
Bakırtaş Palabıyık F, İnci E, Papatya Çakır ED, Hocaoğlu E. Evaluation of Normal Thyroid Tissue and Autoimmune Thyroiditis in Children Using Shear Wave Elastography. J Clin Res Pediatr Endocrinol 2019; 11:132-139. [PMID: 30362325 PMCID: PMC6571532 DOI: 10.4274/jcrpe.galenos.2018.2018.0137] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
OBJECTIVE Shear wave elastography (SWE) is a user-independent ultrasonographic technique that evaluates tissue elasticity. It is used especially in the evaluation of thyroiditis and thyroid nodules when it is capable of distinguishing malignant from benign thyroiditis in adults. To date, no studies have evaluated SWE in pediatric thyroid patients. The aim of this study was to measure the elasticity of normal thyroid tissue in children and adolescents using SWE and to investigate its role in the diagnosis of pediatric autoimmune thyroiditis. METHODS In total, 113 healthy children of whom 66 (58.4%) were girls and 57 children with autoimmune thyroiditis of whom 45 (78.9%) were girls were evaluated by SWE after B-mode ultrasound. The quantitative evaluation of normal thyroid tissue in healthy children and those with autoimmune thyroiditis was performed using shear wave velocity (SWV) values (m/s). Thyroid antibodies were consistent with autoimmune thyroiditis. Data were compared using descriptive and analytical statistics and receiver-operating characteristic curves. RESULTS The mean ± standard deviation (range) of SWV value in thyroid parenchyma of the healthy children was 1.82±0.3 m/s (1.32-2.37) m/s. There was a significant positive correlation between age and SWV values which increased with age. The average SWV value of thyroid parenchyma in children with autoimmune thyroiditis was 3.7±1.2 (2.59-6.25) m/s which was statistically significantly greater than in healthy children (p=0.00). The cut-off value for elasticity with the highest diagnostic accuracy was 2.39 m/s; sensitivity and specificity were 97.4% and 100% respectively. There was no correlation between elasticity, thyroid function tests and autoantibody concentrations (p>0.05). CONCLUSION SWE is a useful imaging method that can be used with routine ultrasonography in evaluation of the thyroid in children.
Collapse
Affiliation(s)
- Figen Bakırtaş Palabıyık
- University of Health Sciences, Bakırköy Dr. Sadi Konuk Training and Research Hospital, Clinic of Radiology, İstanbul, Turkey
| | - Ercan İnci
- University of Health Sciences, Bakırköy Dr. Sadi Konuk Training and Research Hospital, Clinic of Radiology, İstanbul, Turkey
| | - Esra Deniz Papatya Çakır
- University of Health Sciences, Bakırköy Dr. Sadi Konuk Training and Research Hospital, Clinic of Radiology, Division of Pediatrics, İstanbul, Turkey
| | - Elif Hocaoğlu
- University of Health Sciences, Bakırköy Dr. Sadi Konuk Training and Research Hospital, Clinic of Radiology, İstanbul, Turkey
| |
Collapse
|