1
|
Dizon GV, Huang YJ, Lin FC, Maggay IV, Chang Y, Venault A. Assessment of the Blood Separation Performances of Asymmetric Cellulose Acetate Membranes Prepared through Combined Vapor-Induced Phase Separation and Electrospinning. ACS APPLIED MATERIALS & INTERFACES 2025. [PMID: 40393794 DOI: 10.1021/acsami.5c05283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2025]
Abstract
This study introduces the formation of a composite cellulose acetate (CA) membrane for the removal of blood cells from blood-derived solutions. A vapor-induced phase separation (VIPS) CA membrane formed the bottom layer of the composite membrane. The exposure time to vapors was adjusted with the aim to open the pores of the surface exposed to the nonsolvent and obtain a membrane with a mean pore size of less than 0.4 μm. A 20 min exposure led to few pores in the microfiltration range decorating the top surface, while much more numerous pores were observed on the bottom surface in contact with the substrate during the phase-inversion process. Differences between the top and bottom surface porosity in turn influenced wetting by water. The membranes with fastest top and bottom surfaces wettability were selected. Then, nanofibers with a mean pore size of 2.8 ± 0.3 μm were formed by electrospinning a CA solution on the bottom surface of the VIPS membrane. It resulted in the formation of a composite membrane with an asymmetric structure (large top surface pores and smaller bulk and bottom surface pores). The membranes were proven to be nonhemolytic (hemolysis rate <2%) and showed a plasma clotting time in the range 16-22 min. Applied to the gravity-driven filtration of platelet-poor plasma, platelet-rich plasma, and 10-fold and 5-fold dilutions of whole blood, complete blood count analyses showed that the optimized membrane referred to as 15V-15E could separate all platelets, red blood cells, and white blood cells from plasma (100% removal in each case). In addition, the hemolysis of the filtrate obtained with membrane 15V-15E after separation of the 5-fold dilution was extremely low. While the electrospun layer proved efficient for the gradual removal of most cells, SEM and confocal images also highlighted the efficacy of the VIPS layer to reject cells that managed to penetrate deeper in the bulk. However, a VIPS membrane alone failed (no flow) justifying the need for the composite structure. Overall, these membranes show significant potential for facilitating the separation of cells from plasma, which could be applied to the detection of biomarkers in plasma.
Collapse
Affiliation(s)
- Gian Vincent Dizon
- R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li 32023, Taiwan (R.O.C)
| | - Yu-Jen Huang
- R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li 32023, Taiwan (R.O.C)
| | - Fang-Cheng Lin
- R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li 32023, Taiwan (R.O.C)
| | - Irish Valerie Maggay
- R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li 32023, Taiwan (R.O.C)
| | - Yung Chang
- R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li 32023, Taiwan (R.O.C)
| | - Antoine Venault
- R&D Center for Membrane Technology and Department of Chemical Engineering, Chung Yuan Christian University, Chung-Li 32023, Taiwan (R.O.C)
| |
Collapse
|
2
|
Wang K, Seol H, Cheng A, McKeague N, Carlson M, Degraff W, Huang S, Kim S. Simple Bioparticle Filtration Device Based on an Ultralow-Fouling Zwitterionic Polyurethane Membrane for Rapid Large-Volume Separation of Plasma and Viruses from Whole Blood. MEMBRANES 2023; 13:membranes13050524. [PMID: 37233584 DOI: 10.3390/membranes13050524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 05/14/2023] [Accepted: 05/15/2023] [Indexed: 05/27/2023]
Abstract
Plasma separation from whole blood is oftent required as an essential first step when performing blood tests with a viral assay. However, developing a point-of-care plasma extraction device with a large output and high virus recovery remains a significant obstacle to the success of on-site viral load tests. Here, we report a portable, easy-to-use, cost-efficient, membrane-filtration-based plasma separation device that enables rapid large-volume plasma extraction from whole blood, designed for point-of-care virus assays. The plasma separation is realized by a low-fouling zwitterionic polyurethane-modified cellulose acetate (PCBU-CA) membrane. The zwitterionic coating on the cellulose acetate membrane can decrease surface protein adsorption by 60% and increase plasma permeation by 46% compared with a pristine membrane. The PCBU-CA membrane, with its ultralow-fouling properties, enables rapid plasma separation. The device can yield a total of 1.33 mL plasma from 10 mL whole blood in 10 min. The extracted plasma is cell-free and exhibits a low hemoglobin level. In addition, our device demonstrated a 57.8% T7 phage recovery in the separated plasma. The results of real-time polymerase chain reaction analysis confirmed that the nucleic acid amplification curve of the plasma extracted by our device is comparable to that obtained by centrifugation. With its high plasma yield and good phage recovery, our plasma separation device provides an excellent replacement for traditional plasma separation protocols for point-of-care virus assays and a broad spectrum of clinical tests.
Collapse
Affiliation(s)
- Kun Wang
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Hyang Seol
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Alex Cheng
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
- New Trier High School, New Trier, IL 60093, USA
| | - Nash McKeague
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
- University of Chicago Laboratory Schools, Chicago, IL 60637, USA
| | - Megan Carlson
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Wade Degraff
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| | - Sijia Huang
- Lawrence Livermore National Laboratory, Livermore, CA 94550, USA
| | - Sangil Kim
- Department of Chemical Engineering, University of Illinois at Chicago, Chicago, IL 60607, USA
| |
Collapse
|
3
|
Gradisteanu Pircalabioru G, Iliescu FS, Mihaescu G, Cucu AI, Ionescu ON, Popescu M, Simion M, Burlibasa L, Tica M, Chifiriuc MC, Iliescu C. Advances in the Rapid Diagnostic of Viral Respiratory Tract Infections. Front Cell Infect Microbiol 2022; 12:807253. [PMID: 35252028 PMCID: PMC8895598 DOI: 10.3389/fcimb.2022.807253] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Accepted: 01/04/2022] [Indexed: 12/16/2022] Open
Abstract
Viral infections are a significant public health problem, primarily due to their high transmission rate, various pathological manifestations, ranging from mild to severe symptoms and subclinical onset. Laboratory diagnostic tests for infectious diseases, with a short enough turnaround time, are promising tools to improve patient care, antiviral therapeutic decisions, and infection prevention. Numerous microbiological molecular and serological diagnostic testing devices have been developed and authorised as benchtop systems, and only a few as rapid miniaturised, fully automated, portable digital platforms. Their successful implementation in virology relies on their performance and impact on patient management. This review describes the current progress and perspectives in developing micro- and nanotechnology-based solutions for rapidly detecting human viral respiratory infectious diseases. It provides a nonexhaustive overview of currently commercially available and under-study diagnostic testing methods and discusses the sampling and viral genetic trends as preanalytical components influencing the results. We describe the clinical performance of tests, focusing on alternatives such as microfluidics-, biosensors-, Internet-of-Things (IoT)-based devices for rapid and accurate viral loads and immunological responses detection. The conclusions highlight the potential impact of the newly developed devices on laboratory diagnostic and clinical outcomes.
Collapse
Affiliation(s)
| | - Florina Silvia Iliescu
- National Institute for Research and Development in Microtechnologies—IMT, Bucharest, Romania
| | | | | | - Octavian Narcis Ionescu
- National Institute for Research and Development in Microtechnologies—IMT, Bucharest, Romania
- Petroleum-Gas University of Ploiesti, Ploiesti, Romania
| | - Melania Popescu
- National Institute for Research and Development in Microtechnologies—IMT, Bucharest, Romania
| | - Monica Simion
- National Institute for Research and Development in Microtechnologies—IMT, Bucharest, Romania
| | | | - Mihaela Tica
- Emergency University Hospital, Bucharest, Romania
| | - Mariana Carmen Chifiriuc
- Research Institute of the University of Bucharest, Bucharest, Romania
- Faculty of Biology, University of Bucharest, Bucharest, Romania
- Academy of Romanian Scientists, Bucharest, Romania
- The Romanian Academy, Bucharest, Romania
| | - Ciprian Iliescu
- National Institute for Research and Development in Microtechnologies—IMT, Bucharest, Romania
- Academy of Romanian Scientists, Bucharest, Romania
- Faculty of Applied Chemistry and Materials Science, University “Politehnica” of Bucharest, Bucharest, Romania
| |
Collapse
|
4
|
Gold nanoparticle-decorated metal organic frameworks on immunochromatographic assay for human chorionic gonadotropin detection. Mikrochim Acta 2020; 187:640. [PMID: 33151410 DOI: 10.1007/s00604-020-04617-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Accepted: 10/21/2020] [Indexed: 12/24/2022]
Abstract
Gold nanoparticle-decorated metal organic frameworks (MOF@AuNPs) with significantly enhanced color signal intensity were synthesized through in situ growth of AuNPs on the MOF skeleton. The resultant MOF@AuNP nanocomposites were characterized with 16.7-fold higher absorbance than conventional 40 nm AuNPs (AuNP40). Thus, for the first time, we applied it as a signal amplification label to improve the immunochromatographic assay (ICA) of human chorionic gonadotropin (HCG). The detection limit of our enhanced ICA was 1.69 mIU/mL, which is ca. 10.6-fold improvement in sensitivity compared to traditional AuNP40-ICA. The recoveries of this MOF@AuNPs-ICA ranged from 86.03 to 119.22%, with coefficients of variation of 3.05 to 13.74%. The reliability and practicability were further validated by the clinically used chemiluminescence immunoassay method. Given their excellent signal amplification ability, the proposed MOF@AuNPs could serve as an ideal ICA label for rapid and sensitive detection of disease biomarkers. Graphical abstract.
Collapse
|
5
|
Tripathi S, Agrawal A. Blood Plasma Microfluidic Device: Aiming for the Detection of COVID-19 Antibodies Using an On-Chip ELISA Platform. TRANSACTIONS OF THE INDIAN NATIONAL ACADEMY OF ENGINEERING : AN INTERNATIONAL JOURNAL OF ENGINEERING AND TECHNOLOGY 2020; 5:217-220. [PMID: 38624391 PMCID: PMC7283038 DOI: 10.1007/s41403-020-00123-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 05/27/2020] [Accepted: 06/05/2020] [Indexed: 11/18/2022]
Abstract
COVID-19 is a public health emergency of international concern. Detection of SARS-CoV-2 virus is an important step towards containing the virus spread. Although viral detection using molecular diagnostic methods is quite common and efficient, these methods are prone to errors, laborious and time consuming. There is an urgent need for blood-based tests which are simple to use, accurate, less time consuming, portable and cost-effective. Human blood plasma contains water, proteins, organic and in-organic substances including bacteria and viruses. Blood plasma can be effectively used to detect COVID-19 antibodies. The immune system generates antibodies (IgM/IgG proteins) in response to the virus and identification of these antibodies is related to the presence of the infection in the patient in the past. Therefore, detecting and testing the presence of these antibodies will be extremely useful for monitoring and surveillance of the population (Petherick, Lancet 395:1101-1102, 2020). Herein, we describe and propose a microfluidic ELISA (enzyme-linked immunosorbent assay) system to detect COVID-19 antibodies on a lab-on-chip platform. We propose to first separate plasma from whole human blood using a microfluidic device and subsequently perform the detection of antibodies in the separated plasma using a semi-automated on-chip ELISA.
Collapse
Affiliation(s)
- Siddhartha Tripathi
- Birla Institute of Technology and Science, Pilani, K. K. Birla Goa Campus, Goa, 403726 India
| | - Amit Agrawal
- Indian Institute of Technology Bombay, Powai, Mumbai, 400076 India
| |
Collapse
|
6
|
Xia Y, Chen Y, Tang Y, Cheng G, Yu X, He H, Cao G, Lu H, Liu Z, Zheng SY. Smartphone-Based Point-of-Care Microfluidic Platform Fabricated with a ZnO Nanorod Template for Colorimetric Virus Detection. ACS Sens 2019; 4:3298-3307. [PMID: 31769284 DOI: 10.1021/acssensors.9b01927] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Viruses pose serious infectious disease threats to humans and animals. To significantly decrease the mortality and morbidity caused by virus infections, there is an urgent need of sensitive and rapid point-of-care platforms for virus detection, especially in low-resource settings. Herein, we developed a smartphone-based point-of-care platform for highly sensitive and selective detection of the avian influenza virus based on nanomaterial-enabled colorimetric detection. The 3D nanostructures, which serve as a scaffold for antibody conjugation to capture the avian influenza virus, are made on PDMS herringbone structures with a ZnO nanorod template. After virus capture, the on-chip gold nanoparticle-based colorimetric reaction allows virus detection by naked eyes with a detection limit of 2.7 × 104 EID50/mL, which is one order of magnitude better than that of conventional fluorescence-based ELISA. Furthermore, a smartphone imaging system with data processing capability further improves the detection limit, reaching down to 8 × 103 EID50/mL. The entire virus capture and detection process can be completed in 1.5 h. We envision that this point-of-care microfluidic system integrated with smartphone imaging and colorimetric detection would provide a fast, cheap, sensitive, and user-friendly platform for virus detection in low-resource settings.
Collapse
|
7
|
Detection of Coxiella burnetii Using Silicon Microring Resonator in Patient Blood Plasma. MICROMACHINES 2019; 10:mi10070427. [PMID: 31252533 PMCID: PMC6680664 DOI: 10.3390/mi10070427] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 06/21/2019] [Accepted: 06/25/2019] [Indexed: 11/16/2022]
Abstract
Blood plasma from patients is a powerful resource for diagnosing infectious disease due to it having many genetic materials as well as being relatively easy to obtain. Thus, various biosensors have been investigated for diagnosing diseases in blood plasma. However, there are no optimized and validated sensors for clinical use due to the low sensitivity, complexity, and difficulties of removing the inhibitors from plasma samples. In this study, we described a silicon microring resonator sensor used to detect Coxiella burnetii from the blood plasma of Q-fever patients in a label-free, real-time manner. Q-fever is an infectious disease caused by Coxiella burnetii via direct contact or inhalation aerosols. We validated this biosensor in the blood plasma of 35 clinical samples (including 16 Q fever samples infected with Coxiella burnetii and 19 samples infected with other febrile diseases. The biosensors are capable of rapid (10 min), highly sensitive (87.5%), and specific (89.5%) detection in plasma samples compared to the use of the conventional method.
Collapse
|
8
|
Jin CE, Koo B, Lee EY, Kim JY, Kim SH, Shin Y. Simple and label-free pathogen enrichment via homobifunctional imidoesters using a microfluidic (SLIM) system for ultrasensitive pathogen detection in various clinical specimens. Biosens Bioelectron 2018; 111:66-73. [PMID: 29653418 PMCID: PMC7125596 DOI: 10.1016/j.bios.2018.04.001] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2017] [Revised: 03/16/2018] [Accepted: 04/01/2018] [Indexed: 01/12/2023]
Abstract
Diseases caused by pathogenic microorganisms including bacteria and viruses can cause serious medical issues including death and result in huge economic losses. Despite the myriad of recent advances in the rapid and accurate detection of pathogens, large volume clinical samples with a low concentration of pathogens continue to present challenges for diagnosis and surveillance. We here report a simple and label-free approach via homobifunctional imidoesters (HIs) with a microfluidic platform (SLIM) to efficiently enrich and extract pathogens at low concentrations from clinical samples. The SLIM system consists of an assembled double microfluidic chip for streamlining large volume processing and HIs for capturing pathogens and isolating nucleic acids by both electrostatic and covalent interaction without a chaotropic detergent or bulky instruments. The SLIM system significantly increases the enrichment and extraction rate of pathogens (up to 80% at 10 CFU (colony forming unit) in a 1 mL volume within 50 min). We demonstrated its clinical utility in large sample volumes from 46 clinical specimens including environmental swabs, saliva, and blood plasma. The SLIM system showed higher sensitivity with these samples and could detect pathogens that were below the threshold of detection with other methods. Finally, by combining our SLIM approach with an isothermal optical sensor, pathogens could be detected at a very high sensitivity in blood plasma samples within 80 min via enrichment, extraction and detection steps. Our SLIM system thus provides a simple, reliable, cost-effective and ultrasensitive pathogen diagnosis platform for use with large volume clinical samples and would thus have significant utility for various infectious diseases. SLIM system significantly increases the enrichment and extraction rate of pathogens. Demonstrated its clinical utility in large sample volumes from 46 clinical specimens. A simple, reliable, cost-effective and ultrasensitive pathogen diagnosis platform.
Collapse
Affiliation(s)
- Choong Eun Jin
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Biomedical Engineering Research Center, Asan Institute of Life Sciences, Asan Medical Center, 88 Olympicro-43gil, Songpa-gu, Seoul, Republic of Korea
| | - Bonhan Koo
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Biomedical Engineering Research Center, Asan Institute of Life Sciences, Asan Medical Center, 88 Olympicro-43gil, Songpa-gu, Seoul, Republic of Korea
| | - Eun Yeong Lee
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Biomedical Engineering Research Center, Asan Institute of Life Sciences, Asan Medical Center, 88 Olympicro-43gil, Songpa-gu, Seoul, Republic of Korea
| | - Ji Yeun Kim
- Department of Infectious Disease, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea
| | - Sung-Han Kim
- Department of Infectious Disease, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
| | - Yong Shin
- Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Biomedical Engineering Research Center, Asan Institute of Life Sciences, Asan Medical Center, 88 Olympicro-43gil, Songpa-gu, Seoul, Republic of Korea.
| |
Collapse
|
9
|
Xia Y, Tang Y, Yu X, Wan Y, Chen Y, Lu H, Zheng SY. Label-Free Virus Capture and Release by a Microfluidic Device Integrated with Porous Silicon Nanowire Forest. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2017; 13:10.1002/smll.201603135. [PMID: 27918640 PMCID: PMC5293663 DOI: 10.1002/smll.201603135] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 10/21/2016] [Indexed: 05/18/2023]
Abstract
Viral diseases are perpetual threats to human and animal health. Detection and characterization of viral pathogens require accurate, sensitive, and rapid diagnostic assays. For field and clinical samples, the sample preparation procedures limit the ultimate performance and utility of the overall virus diagnostic protocols. This study presents the development of a microfluidic device embedded with porous silicon nanowire (pSiNW) forest for label-free size-based point-of-care virus capture in a continuous curved flow design. The pSiNW forests with specific interwire spacing are synthesized in situ on both bottom and sidewalls of the microchannels in a batch process. With the enhancement effect of Dean flow, this study demonstrates that about 50% H5N2 avian influenza viruses are physically trapped without device clogging. A unique feature of the device is that captured viruses can be released by inducing self-degradation of the pSiNWs in physiological aqueous environment. About 60% of captured viruses can be released within 24 h for virus culture, subsequent molecular diagnosis, and other virus characterization and analyses. This device performs viable, unbiased, and label-free virus isolation and release. It has great potentials for virus discovery, virus isolation and culture, functional studies of virus pathogenicity, transmission, drug screening, and vaccine development.
Collapse
Affiliation(s)
- Yiqiu Xia
- Department of Biomedical Engineering, Micro & Nano Integrated Biosystem (MINIBio) Laboratory, The Pennsylvania State University, University Park, PA 16802, U.S.A
| | - Yi Tang
- Department of Veterinary and Biomedical Science, The Pennsylvania State University, University Park, PA 16802, U.S.A
| | - Xu Yu
- Department of Biomedical Engineering, Micro & Nano Integrated Biosystem (MINIBio) Laboratory, The Pennsylvania State University, University Park, PA 16802, U.S.A
| | - Yuan Wan
- Department of Biomedical Engineering, Micro & Nano Integrated Biosystem (MINIBio) Laboratory, The Pennsylvania State University, University Park, PA 16802, U.S.A
| | - Yizhu Chen
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802, U.S.A
| | - Huaguang Lu
- Department of Veterinary and Biomedical Science, The Pennsylvania State University, University Park, PA 16802, U.S.A
| | - Si-Yang Zheng
- Department of Biomedical Engineering, Micro & Nano Integrated Biosystem (MINIBio) Laboratory, The Pennsylvania State University, University Park, PA 16802, U.S.A
- Department of Electrical Engineering, The Pennsylvania State University, University Park, PA 16802, U.S.A
- Material Research Institute, The Pennsylvania State University, University Park, PA 16802, U.S.A
- Huck Institutes of Life Sciences, The Pennsylvania State University, University Park, PA 16802, U.S.A
| |
Collapse
|
10
|
Yeh YT, Tang Y, Sebastian A, Dasgupta A, Perea-Lopez N, Albert I, Lu H, Terrones M, Zheng SY. Tunable and label-free virus enrichment for ultrasensitive virus detection using carbon nanotube arrays. SCIENCE ADVANCES 2016; 2:e1601026. [PMID: 27730213 PMCID: PMC5055386 DOI: 10.1126/sciadv.1601026] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2016] [Accepted: 08/31/2016] [Indexed: 05/13/2023]
Abstract
Viral infectious diseases can erupt unpredictably, spread rapidly, and ravage mass populations. Although established methods, such as polymerase chain reaction, virus isolation, and next-generation sequencing have been used to detect viruses, field samples with low virus count pose major challenges in virus surveillance and discovery. We report a unique carbon nanotube size-tunable enrichment microdevice (CNT-STEM) that efficiently enriches and concentrates viruses collected from field samples. The channel sidewall in the microdevice was made by growing arrays of vertically aligned nitrogen-doped multiwalled CNTs, where the intertubular distance between CNTs could be engineered in the range of 17 to 325 nm to accurately match the size of different viruses. The CNT-STEM significantly improves detection limits and virus isolation rates by at least 100 times. Using this device, we successfully identified an emerging avian influenza virus strain [A/duck/PA/02099/2012(H11N9)] and a novel virus strain (IBDV/turkey/PA/00924/14). Our unique method demonstrates the early detection of emerging viruses and the discovery of new viruses directly from field samples, thus creating a universal platform for effectively remediating viral infectious diseases.
Collapse
Affiliation(s)
- Yin-Ting Yeh
- Micro and Nano Integrated Biosystem Laboratory, Department of Biomedical Engineering, Pennsylvania State University, University Park, PA 16802, USA
- Penn State Material Research Institute, Pennsylvania State University, University Park, PA 16802, USA
| | - Yi Tang
- Department of Veterinary and Biomedical Science, Pennsylvania State University, University Park, PA 16802, USA
| | - Aswathy Sebastian
- Department of Biochemistry and Molecular Biology, Pennsylvania State University, University Park, PA 16802, USA
| | - Archi Dasgupta
- Department of Chemistry, Pennsylvania State University, University Park, PA 16802, USA
| | - Nestor Perea-Lopez
- Department of Physics and Center for 2-Dimensional and Layered Materials, Pennsylvania State University, University Park, PA 16802, USA
| | - Istvan Albert
- Department of Biochemistry and Molecular Biology, Pennsylvania State University, University Park, PA 16802, USA
- Huck Institutes of the Life Sciences, Pennsylvania State University, University Park, PA 16802, USA
| | - Huaguang Lu
- Department of Veterinary and Biomedical Science, Pennsylvania State University, University Park, PA 16802, USA
| | - Mauricio Terrones
- Penn State Material Research Institute, Pennsylvania State University, University Park, PA 16802, USA
- Department of Chemistry, Pennsylvania State University, University Park, PA 16802, USA
- Department of Physics and Center for 2-Dimensional and Layered Materials, Pennsylvania State University, University Park, PA 16802, USA
- Huck Institutes of the Life Sciences, Pennsylvania State University, University Park, PA 16802, USA
- Department of Materials Science and Engineering, Pennsylvania State University, University Park, PA 16802, USA
- Corresponding author. (M.T.); (S.-Y.Z.)
| | - Si-Yang Zheng
- Micro and Nano Integrated Biosystem Laboratory, Department of Biomedical Engineering, Pennsylvania State University, University Park, PA 16802, USA
- Penn State Material Research Institute, Pennsylvania State University, University Park, PA 16802, USA
- Huck Institutes of the Life Sciences, Pennsylvania State University, University Park, PA 16802, USA
- Department of Electrical Engineering, Pennsylvania State University, University Park, PA 16802, USA
- Corresponding author. (M.T.); (S.-Y.Z.)
| |
Collapse
|
11
|
|