1
|
Gaidulis G, Padala M. Computational Modeling of the Subject-Specific Effects of Annuloplasty Ring Sizing on the Mitral Valve to Repair Functional Mitral Regurgitation. Ann Biomed Eng 2023; 51:1984-2000. [PMID: 37344691 PMCID: PMC10826925 DOI: 10.1007/s10439-023-03219-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 04/21/2023] [Indexed: 06/23/2023]
Abstract
Surgical repair of functional mitral regurgitation (FMR) that occurs in nearly 60% of heart failure (HF) patients is currently performed with undersizing mitral annuloplasty (UMA), which lacks short- and long-term durability. Heterogeneity in valve geometry makes tailoring this repair to each patient challenging, and predictive models that can help with planning this surgery are lacking. In this study, we present a 3D echo-derived computational model, to enable subject-specific, pre-surgical planning of the repair. Three computational models of the mitral valve were created from 3D echo data obtained in three pigs with HF and FMR. An annuloplasty ring model in seven sizes was created, each ring was deployed, and post-repair valve closure was simulated. The results indicate that large annuloplasty rings (> 32 mm) were not effective in eliminating regurgitant gaps nor in restoring leaflet coaptation or reducing leaflet stresses and chordal tension. Smaller rings (≤ 32 mm) restored better systolic valve closure in all investigated cases,but excessive valve tethering and restricted motion of the leaflets were still present. This computational study demonstrates that for effective correction of FMR, the extent of annular reduction differs between subjects, and overly reducing the annulus has deleterious effects on the valve.
Collapse
Affiliation(s)
- Gediminas Gaidulis
- Structural Heart Research and Innovation Laboratory, Carlyle Fraser Heart Center at Emory University Hospital Midtown, Atlanta, USA
- Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, USA
| | - Muralidhar Padala
- Structural Heart Research and Innovation Laboratory, Carlyle Fraser Heart Center at Emory University Hospital Midtown, Atlanta, USA.
- Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, USA.
| |
Collapse
|
2
|
Gaidulis G, Suresh KS, Xu D, Padala M. Patient-Specific Three-Dimensional Ultrasound Derived Computational Modeling of the Mitral Valve. Ann Biomed Eng 2022; 50:847-859. [PMID: 35380321 PMCID: PMC10826907 DOI: 10.1007/s10439-022-02960-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Accepted: 03/27/2022] [Indexed: 11/01/2022]
Abstract
Several new techniques to repair the mitral valve affected by functional mitral regurgitation are in development. However, due to the heterogeneity of valve lesions between patients, predicting the outcomes of novel treatment approaches is challenging. We present a patient-specific, 3D ultrasound-derived computational model of the mitral valve for procedure planning, that faithfully mimics the pathological valve dynamics. 3D ultrasound images were obtained in three pigs induced with heart failure and which developed functional mitral regurgitation. For each case, images were segmented, and finite element model of mitral valve was constructed. Annular and papillary muscle dynamics were extracted and imposed as kinematic boundary conditions, and the chordae were pre-strained to induce valve tethering. Valve closure was simulated by applying physiologic transvalvular pressure on the leaflets. Agreement between simulation results and truth datasets was confirmed, with accurate location of regurgitation jets and coaptation defects. Inclusion of kinematic patient-specific boundary conditions was necessary to achieve these results, whereas use of idealized boundary conditions deviated from the truth dataset. Due to the impact of boundary conditions on the model, the effect of repair strategies on valve closure varied as well, indicating that our approach of using patient-specific boundary conditions for mitral valve modeling is valid.
Collapse
Affiliation(s)
- Gediminas Gaidulis
- Structural Heart Research and Innovation Laboratory, Carlyle Fraser Heart Center at Emory University Hospital Midtown, 380B Northyards Blvd NW, Atlanta, GA, 30313, USA
- Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA
| | - Kirthana Sreerangathama Suresh
- Structural Heart Research and Innovation Laboratory, Carlyle Fraser Heart Center at Emory University Hospital Midtown, 380B Northyards Blvd NW, Atlanta, GA, 30313, USA
| | - Dongyang Xu
- Structural Heart Research and Innovation Laboratory, Carlyle Fraser Heart Center at Emory University Hospital Midtown, 380B Northyards Blvd NW, Atlanta, GA, 30313, USA
| | - Muralidhar Padala
- Structural Heart Research and Innovation Laboratory, Carlyle Fraser Heart Center at Emory University Hospital Midtown, 380B Northyards Blvd NW, Atlanta, GA, 30313, USA.
- Division of Cardiothoracic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
| |
Collapse
|
3
|
Galili L, White Zeira A, Marom G. Numerical biomechanics modelling of indirect mitral annuloplasty treatments for functional mitral regurgitation. ROYAL SOCIETY OPEN SCIENCE 2022; 9:211464. [PMID: 35242347 PMCID: PMC8753151 DOI: 10.1098/rsos.211464] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Accepted: 12/14/2021] [Indexed: 05/03/2023]
Abstract
Mitral valve regurgitation (MR) is a common valvular heart disease where an improper closure leads to leakage from the left ventricle into the left atrium. There is a need for less-invasive treatments such as percutaneous repairs for a large inoperable patient population. The aim of this study is to compare several indirect mitral annuloplasty (IMA) percutaneous repair techniques by finite-element analyses. Two types of generic IMA devices were considered, based on coronary sinus vein shortening (IMA-CS) to reduce the annulus perimeter and based on shortening of the anterior-posterior diameter (IMA-AP). The disease, its treatments, and the heart function post-repair were modelled by modifying the living heart human model (Dassault Systèmes). A functional MR pathology that represents ischaemic MR was generated and the IMA treatments were simulated in it, followed by heart function simulations with the devices and leakage quantification from blood flow simulations. All treatments were able to reduce leakage, the IMA-AP device achieved better sealing, and there was a correlation between the IMA-CS device length and the reduction in leakage. The results of this study can help in bringing IMA-AP to market, expanding the use of IMA devices, and optimizing future designs of such devices.
Collapse
Affiliation(s)
- Lee Galili
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Adi White Zeira
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv 6997801, Israel
| |
Collapse
|
4
|
Marom G, Plitman Mayo R, Again N, Raanani E. Numerical Biomechanics Models of the Interaction Between a Novel Transcatheter Mitral Valve Device and the Subvalvular Apparatus. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2021; 16:327-333. [PMID: 33818178 PMCID: PMC8414811 DOI: 10.1177/1556984521999362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Objective Mitral valve regurgitation (MR) is a common valvular heart disease where
improper closing causes leakage. Currently, no transcatheter mitral valve
device is commercially available. Raanani (co-author) and colleagues have
previously proposed a unique rotational implantation, ensuring anchoring by
metallic arms that pull the chordae tendineae. This technique is now being
implemented in a novel device design. The aim of this study is to quantify
the rotational implantation effect on the mitral annulus kinematics and on
the stresses in the chordae and papillary muscles. Methods Finite element analysis of the rotational step of the implantation in a whole
heart model is employed to compare 5 arm designs with varying diameters
(25.9 mm to 32.4 mm) and rotation angles (up to 140°). The arm rotation that
grabs the chordae was modeled when the valve was in systolic
configuration. Results An increase in the rotation angle results in reduced mitral annulus
perimeters. Larger rotation angles led to higher chordae stresses with the
29.8 mm experiencing the maximum stresses. The calculated chordae stresses
suggest that arm diameter should be <27.8 mm and the rotation angle
<120°. Conclusions The upper limit of this diameter range is preferred in order to reduce the
stresses in the papillary muscles while grabbing more chords. The findings
of this study can help improving the design and performance of this unique
device and procedural technique.
Collapse
Affiliation(s)
- Gil Marom
- 26745 School of Mechanical Engineering, Tel Aviv University, Israel
| | | | - Nadav Again
- The Sheba Fund for Health Services and Research, Tel Hashomer, Israel
| | - Ehud Raanani
- 26744 Leviev Cardiothoracic and Vascular Center, Chaim Sheba Medical Center, Tel Hashomer, Israel
| |
Collapse
|
5
|
Toma M, Einstein DR, Kohli K, Caroll SL, Bloodworth CH, Cochran RP, Kunzelman KS, Yoganathan AP. Effect of Edge-to-Edge Mitral Valve Repair on Chordal Strain: Fluid-Structure Interaction Simulations. BIOLOGY 2020; 9:biology9070173. [PMID: 32708356 PMCID: PMC7407795 DOI: 10.3390/biology9070173] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 07/13/2020] [Accepted: 07/16/2020] [Indexed: 11/22/2022]
Abstract
Edge-to-edge repair for mitral valve regurgitation is being increasingly performed in high-surgical risk patients using minimally invasive mitral clipping devices. Known procedural complications include chordal rupture and mitral leaflet perforation. Hence, it is important to quantitatively evaluate the effect of edge-to-edge repair on chordal integrity. in this study, we employ a computational mitral valve model to simulate functional mitral regurgitation (FMR) by creating papillary muscle displacement. Edge-to-edge repair is then modeled by simulated coaptation of the mid portion of the mitral leaflets. in the setting of simulated FMR, edge-to-edge repair was shown to sustain low regurgitant orifice area, until a two fold increase in the inter-papillary muscle distance as compared to the normal mitral valve. Strain in the chordae was evaluated near the papillary muscles and the leaflets. Following edge-to-edge repair, strain near the papillary muscles did not significantly change relative to the unrepaired valve, while strain near the leaflets increased significantly relative to the unrepaired valve. These data demonstrate the potential for computational simulations to aid in the pre-procedural evaluation of possible complications such as chordal rupture and leaflet perforation following percutaneous edge-to-edge repair.
Collapse
Affiliation(s)
- Milan Toma
- Department of Osteopathic Manipulative Medicine, College of Osteopathic Medicine, New York Institute of Technology, Old Westbury Campus, Northern Boulevard, Old Westbury, NY 11568-8000, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
- Correspondence:
| | - Daniel R. Einstein
- Department of Mechanical Engineering, St. Martin’s University, 5000 Abbey Way SE, Lacey, WA 98503, USA;
| | - Keshav Kohli
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| | - Sheridan L. Caroll
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| | - Charles H. Bloodworth
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| | - Richard P. Cochran
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME 04469-5711, USA; (R.P.C.); (K.S.K.)
| | - Karyn S. Kunzelman
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME 04469-5711, USA; (R.P.C.); (K.S.K.)
| | - Ajit P. Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, 387 Technology Circle, Atlanta, GA 30313-2412, USA; (K.K.); (S.L.C.); (C.H.B.IV); (A.P.Y.)
| |
Collapse
|
6
|
Fluid-Structure Interaction Analysis of Subject-Specific Mitral Valve Regurgitation Treatment with an Intra-Valvular Spacer. PROSTHESIS 2020. [DOI: 10.3390/prosthesis2020007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Mitral regurgitation imposes a significant symptomatic burden on patients who are not candidates for conventional surgery. For these patients, transcatheter repair and replacement devices are emerging as alternative options. One such device is an intravalvular balloon or spacer that is inserted between the mitral valve leaflets to fill the gap that gives rise to mitral regurgitation. In this study, we apply a large-deformation fluid-structure interaction analysis to a fully 3D subject-specific mitral valve model to assess the efficacy of the intra-valvular spacer for reducing mitral regurgitation severity. The model includes a topologically 3D subvalvular apparatus with unprecedented detail. Results show that device fixation and anchoring at the location of the subject’s regurgitant orifice is imperative for optimal reduction of mitral regurgitation.
Collapse
|
7
|
Abstract
Heart valve diseases are common disorders with five million annual diagnoses being made in the United States alone. All heart valve disorders alter cardiac hemodynamic performance; therefore, treatments aim to restore normal flow. This paper reviews the state-of-the-art clinical and engineering advancements in heart valve treatments with a focus on hemodynamics. We review engineering studies and clinical literature on the experience with devices for aortic valve treatment, as well as the latest advancements in mitral valve treatments and the pulmonic and tricuspid valves on the right side of the heart. Upcoming innovations will potentially revolutionize treatment of heart valve disorders. These advancements, and more gradual enhancements in the procedural techniques and imaging modalities, could improve the quality of life of patients suffering from valvular disease who currently cannot be treated.
Collapse
Affiliation(s)
- Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv Israel
- To whom correspondence should be addressed. E-mail:
| | - Shmuel Einav
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
8
|
Caballero A, Mao W, McKay R, Sun W. Transapical mitral valve repair with neochordae implantation: FSI analysis of neochordae number and complexity of leaflet prolapse. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3297. [PMID: 31833663 DOI: 10.1002/cnm.3297] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 11/05/2019] [Accepted: 12/09/2019] [Indexed: 06/10/2023]
Abstract
Transapical mitral valve repair with neochordae implantation is a relatively new minimally invasive technique to treat primary mitral regurgitation. Quantifying the complex biomechanical interaction and interdependence between the left heart structures and the neochordae during this procedure is technically challenging. The aim of this parametric computational study is to investigate the immediate effects of neochordae number and complexity of leaflet prolapse on restoring physiologic left heart dynamics after optimal transapical neochordae repair procedures. Neochordae implantation using three and four sutures was modeled under three clinically relevant prolapse conditions: isolated P2, multi-scallop P2/P3, and multi-scallop P2/P1. A fluid-structure interaction (FSI) modeling framework was used to evaluate the left heart dynamics under baseline, prerepair, and postrepair states. Despite immediate restoration of leaflet coaptation and no residual mitral regurgitation in all postrepair models, the average and peak stresses in the repaired scallop(s) increased >40% and >100%, respectively, compared with the baseline state. Additionally, anterior mitral leaflet marginal chordae tension increased >30%, while posterior mitral leaflet chordae tension decreased at least 30%. No marked differences in hemodynamic performance, in native and neochordae forces, and in leaflet stress were found when implanting three or four sutures. We report, to our knowledge, the first set of time-dependent in silico FSI human neochordae tension measurements during transapical neochordae repair. This work represents a further step towards an improved understanding of the biomechanical outcomes of minimally invasive mitral valve repair procedures.
Collapse
Affiliation(s)
- Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| | - Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| | - Raymond McKay
- Division of Cardiology, The Hartford Hospital, Hartford, Connecticut
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
| |
Collapse
|
9
|
Jaworek M, Pappalardo OA, Selmi M, Gelpi G, Romagnoni C, Lucherini F, Ajmone-Marsan N, Redaelli A, Fiore GB, Votta E, Antona C, Vismara R. Treatment of Tricuspid Regurgitation at Subvalvular Level: Hemodynamic and Morphological Assessment in Ex-Vivo Beating Heart Model. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM 2019. [DOI: 10.1080/24748706.2019.1686555] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Michal Jaworek
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
| | - Omar A. Pappalardo
- 3D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy
| | - Matteo Selmi
- Division of Cardiac Surgery, Department of Surgery, Università di Verona, Verona, Italy
| | - Guido Gelpi
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
- Cardiovascular Surgery Department, ASST Fatebenefratelli Luigi Sacco University Hospital, Milan, Italy
| | - Claudia Romagnoni
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
- Cardiovascular Surgery Department, ASST Fatebenefratelli Luigi Sacco University Hospital, Milan, Italy
| | - Federico Lucherini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
| | - Nina Ajmone-Marsan
- Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Gianfranco B. Fiore
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
| | - Emiliano Votta
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Carlo Antona
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
- Cardiovascular Surgery Department, ASST Fatebenefratelli Luigi Sacco University Hospital, Milan, Italy
| | - Riccardo Vismara
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
- ForcardioLab – Fondazione per la Ricerca in Cardiochirurgia ONLUS, Milan, Italy
| |
Collapse
|
10
|
Caballero A, Mao W, McKay R, Primiano C, Hashim S, Sun W. New insights into mitral heart valve prolapse after chordae rupture through fluid-structure interaction computational modeling. Sci Rep 2018; 8:17306. [PMID: 30470812 PMCID: PMC6251907 DOI: 10.1038/s41598-018-35555-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Accepted: 11/07/2018] [Indexed: 12/19/2022] Open
Abstract
Mitral valve (MV) dynamics depends on a force balance across the mitral leaflets, the chordae tendineae, the mitral annulus, the papillary muscles and the adjacent ventricular wall. Chordae rupture disrupts the link between the MV and the left ventricle (LV), causing mitral regurgitation (MR), the most common valvular disease. In this study, a fluid-structure interaction (FSI) modeling framework is implemented to investigate the impact of chordae rupture on the left heart (LH) dynamics and severity of MR. A control and seven chordae rupture LH models were developed to simulate a pathological process in which minimal chordae rupture precedes more extensive chordae rupture. Different non-eccentric and eccentric regurgitant jets were identified during systole. Cardiac efficiency was evaluated by the ratio of external stroke work. MV structural results showed that basal/strut chordae were the major load-bearing chordae. An increased number of ruptured chordae resulted in reduced basal/strut tension, but increased marginal/intermediate load. Chordae rupture in a specific scallop did not necessarily involve an increase in the stress of the entire prolapsed leaflet. This work represents a further step towards patient-specific modeling of pathological LH dynamics, and has the potential to improve our understanding of the biomechanical mechanisms and treatment of primary MR.
Collapse
Affiliation(s)
- Andrés Caballero
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Wenbin Mao
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA
| | - Raymond McKay
- Cardiology and Cardiac Surgery, The Hartford Hospital, Hartford, Connecticut, USA
| | - Charles Primiano
- Cardiology and Cardiac Surgery, The Hartford Hospital, Hartford, Connecticut, USA
| | - Sabet Hashim
- Cardiology and Cardiac Surgery, The Hartford Hospital, Hartford, Connecticut, USA
| | - Wei Sun
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, USA.
| |
Collapse
|
11
|
Govindarajan V, Mousel J, Udaykumar HS, Vigmostad SC, McPherson DD, Kim H, Chandran KB. Synergy between Diastolic Mitral Valve Function and Left Ventricular Flow Aids in Valve Closure and Blood Transport during Systole. Sci Rep 2018; 8:6187. [PMID: 29670148 PMCID: PMC5906696 DOI: 10.1038/s41598-018-24469-x] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 03/27/2018] [Indexed: 11/30/2022] Open
Abstract
Highly resolved three-dimensional (3D) fluid structure interaction (FSI) simulation using patient-specific echocardiographic data can be a powerful tool for accurately and thoroughly elucidating the biomechanics of mitral valve (MV) function and left ventricular (LV) fluid dynamics. We developed and validated a strongly coupled FSI algorithm to fully characterize the LV flow field during diastolic MV opening under physiologic conditions. Our model revealed that distinct MV deformation and LV flow patterns developed during different diastolic stages. A vortex ring that strongly depended on MV deformation formed during early diastole. At peak E wave, the MV fully opened, with a local Reynolds number of ~5500, indicating that the flow was in the laminar-turbulent transitional regime. Our results showed that during diastasis, the vortex structures caused the MV leaflets to converge, thus increasing mitral jet’s velocity. The vortex ring became asymmetrical, with the vortex structures on the anterior side being larger than on the posterior side. During the late diastolic stages, the flow structures advected toward the LV outflow tract, enhancing fluid transport to the aorta. This 3D-FSI study demonstrated the importance of leaflet dynamics, their effect on the vortex ring, and their influence on MV function and fluid transport within the LV during diastole.
Collapse
Affiliation(s)
- Vijay Govindarajan
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA.,Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas McGovern Medical School, Houston, TX, USA
| | - John Mousel
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - H S Udaykumar
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - Sarah C Vigmostad
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA
| | - David D McPherson
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas McGovern Medical School, Houston, TX, USA
| | - Hyunggun Kim
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas McGovern Medical School, Houston, TX, USA. .,Department of Biomechatronic Engineering, Sungkyunkwan University, Suwon, Gyeonggi, Korea.
| | - Krishnan B Chandran
- Department of Biomedical Engineering, The University of Iowa, Iowa City, IA, USA.
| |
Collapse
|
12
|
Gao H, Qi N, Feng L, Ma X, Danton M, Berry C, Luo X. Modelling mitral valvular dynamics-current trend and future directions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:e2858. [PMID: 27935265 PMCID: PMC5697636 DOI: 10.1002/cnm.2858] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2016] [Revised: 09/30/2016] [Accepted: 11/26/2016] [Indexed: 05/19/2023]
Abstract
Dysfunction of mitral valve causes morbidity and premature mortality and remains a leading medical problem worldwide. Computational modelling aims to understand the biomechanics of human mitral valve and could lead to the development of new treatment, prevention and diagnosis of mitral valve diseases. Compared with the aortic valve, the mitral valve has been much less studied owing to its highly complex structure and strong interaction with the blood flow and the ventricles. However, the interest in mitral valve modelling is growing, and the sophistication level is increasing with the advanced development of computational technology and imaging tools. This review summarises the state-of-the-art modelling of the mitral valve, including static and dynamics models, models with fluid-structure interaction, and models with the left ventricle interaction. Challenges and future directions are also discussed.
Collapse
Affiliation(s)
- Hao Gao
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Nan Qi
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | - Liuyang Feng
- School of Mathematics and StatisticsUniversity of GlasgowUK
| | | | - Mark Danton
- Department of Cardiac SurgeryRoyal Hospital for ChildrenGlasgowUK
| | - Colin Berry
- Institute of Cardiovascular and Medical SciencesUniversity of GlasgowUK
| | - Xiaoyu Luo
- School of Mathematics and StatisticsUniversity of GlasgowUK
| |
Collapse
|
13
|
Mao W, Caballero A, McKay R, Primiano C, Sun W. Fully-coupled fluid-structure interaction simulation of the aortic and mitral valves in a realistic 3D left ventricle model. PLoS One 2017; 12:e0184729. [PMID: 28886196 PMCID: PMC5590990 DOI: 10.1371/journal.pone.0184729] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2017] [Accepted: 08/29/2017] [Indexed: 12/17/2022] Open
Abstract
In this study, we present a fully-coupled fluid-structure interaction (FSI) framework that combines smoothed particle hydrodynamics (SPH) and nonlinear finite element (FE) method to investigate the coupled aortic and mitral valves structural response and the bulk intraventricular hemodynamics in a realistic left ventricle (LV) model during the entire cardiac cycle. The FSI model incorporates valve structures that consider native asymmetric leaflet geometries, anisotropic hyperelastic material models and human material properties. Comparison of FSI results with subject-specific echocardiography data demonstrates that the SPH-FE approach is able to quantitatively predict the opening and closing times of the valves, the mitral leaflet opening and closing angles, and the large-scale intraventricular flow phenomena with a reasonable agreement. Moreover, comparison of FSI results with a LV model without valves reveals substantial differences in the flow field. Peak systolic velocities obtained from the FSI model and the LV model without valves are 2.56 m/s and 1.16 m/s, respectively, compared to the Doppler echo data of 2.17 m/s. The proposed SPH-FE FSI framework represents a further step towards modeling patient-specific coupled LV-valve dynamics, and has the potential to improve our understanding of cardiovascular physiology and to support professionals in clinical decision-making.
Collapse
Affiliation(s)
- Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States of America
| | - Andrés Caballero
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States of America
| | - Raymond McKay
- Cardiology Department, The Hartford Hospital, Hartford, Connecticut, United States of America
| | - Charles Primiano
- Cardiology Department, The Hartford Hospital, Hartford, Connecticut, United States of America
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, United States of America
| |
Collapse
|
14
|
Toyama Y, Kanda H, Igarashi K, Iwasaki H, Kanao-Kanda M, Iida T, Kunisawa T. Morphologic Evaluation of the Mitral Annulus During Displacement of the Heart in Off-Pump Coronary Artery Bypass Surgery. J Cardiothorac Vasc Anesth 2017; 32:334-340. [PMID: 29217239 DOI: 10.1053/j.jvca.2017.08.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To evaluate the morphologic changes of the mitral annulus using 3-dimensional transesophageal echocardiography during heart displacement to expose the anastomosis site in off-pump coronary artery bypass surgery (OPCAB). DESIGN Prospective case series. SETTING Single center, university hospital. PARTICIPANTS The study comprised 34 consecutive patients who underwent OPCAB of the left circumflex artery (LCX) and the right coronary artery (RCA). INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Mitral annulus parameters were measured using the Mitral Valve Quantification program after sternotomy (physiologic position) and during displacement of the heart to expose the LCX (LCX position) and the RCA (RCA position). The height of the mitral annulus was significantly lower in the LCX (5.76 ± 0.90 mm) and RCA (5.92 ± 0.97 mm) positions than in the physiologic position (6.96 ± 0.99 mm; both p < 0.0001). The percent change in the height of the mitral annulus was significantly greater in the mitral regurgitation group than in the mitral regurgitation nondeterioration group when in the LCX (-16.3% ± 6.0% v -11.9% ± 3.3%, p = 0.0203) and RCA (-16.9% ± 6.3% v -12.1% ± 3.8%, p = 0.0207) positions. The anteroposterior and intercommissural diameters, annulus perimeter, and surface area of the mitral annulus did not differ significantly among all heart positions. CONCLUSIONS The mitral annulus flattened and lost its saddle shape without expanding while in the LCX and RCA positions. The greater percent change in the height of the mitral annulus may aggravate mitral regurgitation.
Collapse
Affiliation(s)
- Yuki Toyama
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Hokkaido, Japan.
| | - Hirotsugu Kanda
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | | | - Hajime Iwasaki
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Megumi Kanao-Kanda
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Takafumi Iida
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| | - Takayuki Kunisawa
- Department of Anesthesiology and Critical Care Medicine, Asahikawa Medical University, Asahikawa, Hokkaido, Japan
| |
Collapse
|
15
|
Gao H, Feng L, Qi N, Berry C, Griffith BE, Luo X. A coupled mitral valve-left ventricle model with fluid-structure interaction. Med Eng Phys 2017; 47:128-136. [PMID: 28751011 PMCID: PMC6779302 DOI: 10.1016/j.medengphy.2017.06.042] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 06/13/2017] [Accepted: 06/24/2017] [Indexed: 12/16/2022]
Abstract
Understanding the interaction between the valves and walls of the heart is important in assessing and subsequently treating heart dysfunction. This study presents an integrated model of the mitral valve (MV) coupled to the left ventricle (LV), with the geometry derived from in vivo clinical magnetic resonance images. Numerical simulations using this coupled MV-LV model are developed using an immersed boundary/finite element method. The model incorporates detailed valvular features, left ventricular contraction, nonlinear soft tissue mechanics, and fluid-mediated interactions between the MV and LV wall. We use the model to simulate cardiac function from diastole to systole. Numerically predicted LV pump function agrees well with in vivo data of the imaged healthy volunteer, including the peak aortic flow rate, the systolic ejection duration, and the LV ejection fraction. In vivo MV dynamics are qualitatively captured. We further demonstrate that the diastolic filling pressure increases significantly with impaired myocardial active relaxation to maintain a normal cardiac output. This is consistent with clinical observations. The coupled model has the potential to advance our fundamental knowledge of mechanisms underlying MV-LV interaction, and help in risk stratification and optimisation of therapies for heart diseases.
Collapse
Affiliation(s)
- Hao Gao
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK.
| | - Liuyang Feng
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| | - Nan Qi
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| | - Colin Berry
- Institute of Cardiovascular and Medical Science, University of Glasgow, Glasgow, UK
| | - Boyce E Griffith
- Departments of Mathematics and Biomedical Engineering and McAllister Heart Institute, University of North Carolina, Chapel Hill, NC, USA
| | - Xiaoyu Luo
- School of Mathematics and Statistics, University of Glasgow, Glasgow, UK
| |
Collapse
|
16
|
Bertrand PB, Schwammenthal E, Levine RA, Vandervoort PM. Exercise Dynamics in Secondary Mitral Regurgitation: Pathophysiology and Therapeutic Implications. Circulation 2017; 135:297-314. [PMID: 28093494 DOI: 10.1161/circulationaha.116.025260] [Citation(s) in RCA: 83] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Secondary mitral valve regurgitation (MR) remains a challenging problem in the diagnostic workup and treatment of patients with heart failure. Although secondary MR is characteristically dynamic in nature and sensitive to changes in ventricular geometry and loading, current therapy is mainly focused on resting conditions. An exercise-induced increase in secondary MR, however, is associated with impaired exercise capacity and increased mortality. In an era where a multitude of percutaneous solutions are emerging for the treatment of patients with heart failure, it becomes important to address the dynamic component of secondary MR during exercise as well. A critical reappraisal of the underlying disease mechanisms, in particular the dynamic component during exercise, is of timely importance. This review summarizes the pathophysiological mechanisms involved in the dynamic deterioration of secondary MR during exercise, its functional and prognostic impact, and the way current treatment options affect the dynamic lesion and exercise hemodynamics in general.
Collapse
Affiliation(s)
- Philippe B Bertrand
- From Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (P.B.B., P.M.V.); Faculty of Medicine and Life Sciences, Hasselt University, Belgium (P.B.B., P.M.V.); Heart Center, Sheba Medical Center, Tel Hashomer, Israel (E.S.); and Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston (R.A.L.).
| | - Ehud Schwammenthal
- From Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (P.B.B., P.M.V.); Faculty of Medicine and Life Sciences, Hasselt University, Belgium (P.B.B., P.M.V.); Heart Center, Sheba Medical Center, Tel Hashomer, Israel (E.S.); and Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston (R.A.L.)
| | - Robert A Levine
- From Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (P.B.B., P.M.V.); Faculty of Medicine and Life Sciences, Hasselt University, Belgium (P.B.B., P.M.V.); Heart Center, Sheba Medical Center, Tel Hashomer, Israel (E.S.); and Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston (R.A.L.)
| | - Pieter M Vandervoort
- From Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (P.B.B., P.M.V.); Faculty of Medicine and Life Sciences, Hasselt University, Belgium (P.B.B., P.M.V.); Heart Center, Sheba Medical Center, Tel Hashomer, Israel (E.S.); and Cardiac Ultrasound Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston (R.A.L.)
| |
Collapse
|
17
|
Toma M, Einstein DR, Bloodworth CH, Cochran RP, Yoganathan AP, Kunzelman KS. Fluid-structure interaction and structural analyses using a comprehensive mitral valve model with 3D chordal structure. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2017; 33:10.1002/cnm.2815. [PMID: 27342229 PMCID: PMC5183567 DOI: 10.1002/cnm.2815] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Revised: 05/24/2016] [Accepted: 06/13/2016] [Indexed: 05/18/2023]
Abstract
Over the years, three-dimensional models of the mitral valve have generally been organized around a simplified anatomy. Leaflets have been typically modeled as membranes, tethered to discrete chordae typically modeled as one-dimensional, non-linear cables. Yet, recent, high-resolution medical images have revealed that there is no clear boundary between the chordae and the leaflets. In fact, the mitral valve has been revealed to be more of a webbed structure whose architecture is continuous with the chordae and their extensions into the leaflets. Such detailed images can serve as the basis of anatomically accurate, subject-specific models, wherein the entire valve is modeled with solid elements that more faithfully represent the chordae, the leaflets, and the transition between the two. These models have the potential to enhance our understanding of mitral valve mechanics and to re-examine the role of the mitral valve chordae, which heretofore have been considered to be 'invisible' to the fluid and to be of secondary importance to the leaflets. However, these new models also require a rethinking of modeling assumptions. In this study, we examine the conventional practice of loading the leaflets only and not the chordae in order to study the structural response of the mitral valve apparatus. Specifically, we demonstrate that fully resolved 3D models of the mitral valve require a fluid-structure interaction analysis to correctly load the valve even in the case of quasi-static mechanics. While a fluid-structure interaction mode is still more computationally expensive than a structural-only model, we also show that advances in GPU computing have made such models tractable. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Milan Toma
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, 30313-2412, GA, U.S.A
| | - Daniel R Einstein
- Department of Mechanical Engineering, St. Martin's University, 5000 Abbey Way SE, Lacey, 98503, WA, U.S.A
| | - Charles H Bloodworth
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, 30313-2412, GA, U.S.A
| | - Richard P Cochran
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, 04469-5711, ME, U.S.A
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, 30313-2412, GA, U.S.A
| | - Karyn S Kunzelman
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, 04469-5711, ME, U.S.A
| |
Collapse
|
18
|
Toma M, Bloodworth CH, Pierce EL, Einstein DR, Cochran RP, Yoganathan AP, Kunzelman KS. Fluid-Structure Interaction Analysis of Ruptured Mitral Chordae Tendineae. Ann Biomed Eng 2017; 45:619-631. [PMID: 27624659 PMCID: PMC5332285 DOI: 10.1007/s10439-016-1727-y] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 09/02/2016] [Indexed: 10/21/2022]
Abstract
The chordal structure is a part of mitral valve geometry that has been commonly neglected or simplified in computational modeling due to its complexity. However, these simplifications cannot be used when investigating the roles of individual chordae tendineae in mitral valve closure. For the first time, advancements in imaging, computational techniques, and hardware technology make it possible to create models of the mitral valve without simplifications to its complex geometry, and to quickly run validated computer simulations that more realistically capture its function. Such simulations can then be used for a detailed analysis of chordae-related diseases. In this work, a comprehensive model of a subject-specific mitral valve with detailed chordal structure is used to analyze the distinct role played by individual chordae in closure of the mitral valve leaflets. Mitral closure was simulated for 51 possible chordal rupture points. Resultant regurgitant orifice area and strain change in the chordae at the papillary muscle tips were then calculated to examine the role of each ruptured chorda in the mitral valve closure. For certain subclassifications of chordae, regurgitant orifice area was found to trend positively with ruptured chordal diameter, and strain changes correlated negatively with regurgitant orifice area. Further advancements in clinical imaging modalities, coupled with the next generation of computational techniques will enable more physiologically realistic simulations.
Collapse
Affiliation(s)
- Milan Toma
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Charles H Bloodworth
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Eric L Pierce
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Daniel R Einstein
- Department of Mechanical Engineering, St. Martin's University, 5000 Abbey Way SE, Lacey, WA, 98503, USA
| | - Richard P Cochran
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME, 04469-5711, USA
| | - Ajit P Yoganathan
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA.
| | - Karyn S Kunzelman
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME, 04469-5711, USA
| |
Collapse
|
19
|
High-resolution subject-specific mitral valve imaging and modeling: experimental and computational methods. Biomech Model Mechanobiol 2016; 15:1619-1630. [PMID: 27094182 DOI: 10.1007/s10237-016-0786-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Accepted: 03/29/2016] [Indexed: 10/21/2022]
Abstract
The diversity of mitral valve (MV) geometries and multitude of surgical options for correction of MV diseases necessitates the use of computational modeling. Numerical simulations of the MV would allow surgeons and engineers to evaluate repairs, devices, procedures, and concepts before performing them and before moving on to more costly testing modalities. Constructing, tuning, and validating these models rely upon extensive in vitro characterization of valve structure, function, and response to change due to diseases. Micro-computed tomography ([Formula: see text]CT) allows for unmatched spatial resolution for soft tissue imaging. However, it is still technically challenging to obtain an accurate geometry of the diastolic MV. We discuss here the development of a novel technique for treating MV specimens with glutaraldehyde fixative in order to minimize geometric distortions in preparation for [Formula: see text]CT scanning. The technique provides a resulting MV geometry which is significantly more detailed in chordal structure, accurate in leaflet shape, and closer to its physiological diastolic geometry. In this paper, computational fluid-structure interaction (FSI) simulations are used to show the importance of more detailed subject-specific MV geometry with 3D chordal structure to simulate a proper closure validated against [Formula: see text]CT images of the closed valve. Two computational models, before and after use of the aforementioned technique, are used to simulate closure of the MV.
Collapse
|
20
|
Toma M, Jensen MØ, Einstein DR, Yoganathan AP, Cochran RP, Kunzelman KS. Fluid-Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure. Ann Biomed Eng 2015; 44:942-53. [PMID: 26183963 DOI: 10.1007/s10439-015-1385-5] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 07/07/2015] [Indexed: 11/28/2022]
Abstract
Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid-structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with [Formula: see text]CT. Experimental data from the in vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed leaflet dynamics, and force vectors from the in vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements enable validating and adjusting material parameters to improve the accuracy of computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.
Collapse
Affiliation(s)
- Milan Toma
- Department of Biomedical Engineering, Georgia Institute of Technology, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Morten Ø Jensen
- Department of Biomedical Engineering, Georgia Institute of Technology, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Daniel R Einstein
- Computational Biology & Bioinformatics, Pacific Northwest National Laboratory, Richland, WA, 99352, USA
| | - Ajit P Yoganathan
- Department of Biomedical Engineering, Georgia Institute of Technology, Technology Enterprise Park, Suite 200, 387 Technology Circle, Atlanta, GA, 30313-2412, USA
| | - Richard P Cochran
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME, 04469-5711, USA
| | - Karyn S Kunzelman
- Department of Mechanical Engineering, University of Maine, 219 Boardman Hall, Orono, ME, 04469-5711, USA.
| |
Collapse
|
21
|
Rim Y, Choi A, McPherson DD, Kim H. Personalized Computational Modeling of Mitral Valve Prolapse: Virtual Leaflet Resection. PLoS One 2015; 10:e0130906. [PMID: 26103002 PMCID: PMC4477933 DOI: 10.1371/journal.pone.0130906] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Accepted: 05/25/2015] [Indexed: 11/23/2022] Open
Abstract
Posterior leaflet prolapse following chordal elongation or rupture is one of the primary valvular diseases in patients with degenerative mitral valves (MVs). Quadrangular resection followed by ring annuloplasty is a reliable and reproducible surgical repair technique for treatment of posterior leaflet prolapse. Virtual MV repair simulation of leaflet resection in association with patient-specific 3D echocardiographic data can provide quantitative biomechanical and physiologic characteristics of pre- and post-resection MV function. We have developed a solid personalized computational simulation protocol to perform virtual MV repair using standard clinical guidelines of posterior leaflet resection with annuloplasty ring implantation. A virtual MV model was created using 3D echocardiographic data of a patient with posterior chordal rupture and severe mitral regurgitation. A quadrangle-shaped leaflet portion in the prolapsed posterior leaflet was removed, and virtual plication and suturing were performed. An annuloplasty ring of proper size was reconstructed and virtual ring annuloplasty was performed by superimposing the ring and the mitral annulus. Following the quadrangular resection and ring annuloplasty simulations, patient-specific annular motion and physiologic transvalvular pressure gradient were implemented and dynamic finite element simulation of MV function was performed. The pre-resection MV demonstrated a substantial lack of leaflet coaptation which directly correlated with the severe mitral regurgitation. Excessive stress concentration was found along the free marginal edge of the posterior leaflet involving the chordal rupture. Following the virtual resection and ring annuloplasty, the severity of the posterior leaflet prolapse markedly decreased. Excessive stress concentration disappeared over both anterior and posterior leaflets, and complete leaflet coaptation was effectively restored. This novel personalized virtual MV repair strategy has great potential to help with preoperative selection of the patient-specific optimal MV repair techniques, allow innovative surgical planning to expect improved efficacy of MV repair with more predictable outcomes, and ultimately provide more effective medical care for the patient.
Collapse
Affiliation(s)
- Yonghoon Rim
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas Health Science Center at Houston, Houston, Texas, United States of America
| | - Ahnryul Choi
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas Health Science Center at Houston, Houston, Texas, United States of America
| | - David D. McPherson
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas Health Science Center at Houston, Houston, Texas, United States of America
| | - Hyunggun Kim
- Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Texas Health Science Center at Houston, Houston, Texas, United States of America
| |
Collapse
|