1
|
Hajam MI, Khan MM. Microfluidics: a concise review of the history, principles, design, applications, and future outlook. Biomater Sci 2024; 12:218-251. [PMID: 38108438 DOI: 10.1039/d3bm01463k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
Microfluidic technologies have garnered significant attention due to their ability to rapidly process samples and precisely manipulate fluids in assays, making them an attractive alternative to conventional experimental methods. With the potential for revolutionary capabilities in the future, this concise review provides readers with insights into the fascinating world of microfluidics. It begins by introducing the subject's historical background, allowing readers to familiarize themselves with the basics. The review then delves into the fundamental principles, discussing the underlying phenomena at play. Additionally, it highlights the different aspects of microfluidic device design, classification, and fabrication. Furthermore, the paper explores various applications, the global market, recent advancements, and challenges in the field. Finally, the review presents a positive outlook on trends and draws lessons to support the future flourishing of microfluidic technologies.
Collapse
Affiliation(s)
- Mohammad Irfan Hajam
- Department of Mechanical Engineering, National Institute of Technology Srinagar, India.
| | - Mohammad Mohsin Khan
- Department of Mechanical Engineering, National Institute of Technology Srinagar, India.
| |
Collapse
|
2
|
Peng W, Reyes CDG, Gautam S, Yu A, Cho BG, Goli M, Donohoo K, Mondello S, Kobeissy F, Mechref Y. MS-based glycomics and glycoproteomics methods enabling isomeric characterization. MASS SPECTROMETRY REVIEWS 2023; 42:577-616. [PMID: 34159615 PMCID: PMC8692493 DOI: 10.1002/mas.21713] [Citation(s) in RCA: 37] [Impact Index Per Article: 37.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 06/01/2021] [Accepted: 06/02/2021] [Indexed: 05/03/2023]
Abstract
Glycosylation is one of the most significant and abundant posttranslational modifications in mammalian cells. It mediates a wide range of biofunctions, including cell adhesion, cell communication, immune cell trafficking, and protein stability. Also, aberrant glycosylation has been associated with various diseases such as diabetes, Alzheimer's disease, inflammation, immune deficiencies, congenital disorders, and cancers. The alterations in the distributions of glycan and glycopeptide isomers are involved in the development and progression of several human diseases. However, the microheterogeneity of glycosylation brings a great challenge to glycomic and glycoproteomic analysis, including the characterization of isomers. Over several decades, different methods and approaches have been developed to facilitate the characterization of glycan and glycopeptide isomers. Mass spectrometry (MS) has been a powerful tool utilized for glycomic and glycoproteomic isomeric analysis due to its high sensitivity and rich structural information using different fragmentation techniques. However, a comprehensive characterization of glycan and glycopeptide isomers remains a challenge when utilizing MS alone. Therefore, various separation methods, including liquid chromatography, capillary electrophoresis, and ion mobility, were developed to resolve glycan and glycopeptide isomers before MS. These separation techniques were coupled to MS for a better identification and quantitation of glycan and glycopeptide isomers. Additionally, bioinformatic tools are essential for the automated processing of glycan and glycopeptide isomeric data to facilitate isomeric studies in biological cohorts. Here in this review, we discuss commonly employed MS-based techniques, separation hyphenated MS methods, and software, facilitating the separation, identification, and quantitation of glycan and glycopeptide isomers.
Collapse
Affiliation(s)
- Wenjing Peng
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| | | | - Sakshi Gautam
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| | - Aiying Yu
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| | - Byeong Gwan Cho
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| | - Mona Goli
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| | - Kaitlyn Donohoo
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| | | | - Firas Kobeissy
- Program for Neurotrauma, Neuroproteomics & Biomarkers Research, Departments of Emergency Medicine, University of Florida, Gainesville, Florida, USA
| | - Yehia Mechref
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas, USA
| |
Collapse
|
3
|
Peng W, Kobeissy F, Mondello S, Barsa C, Mechref Y. MS-based glycomics: An analytical tool to assess nervous system diseases. Front Neurosci 2022; 16:1000179. [PMID: 36408389 PMCID: PMC9671362 DOI: 10.3389/fnins.2022.1000179] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Accepted: 10/05/2022] [Indexed: 08/27/2023] Open
Abstract
Neurological diseases affect millions of peopleochemistryorldwide and are continuously increasing due to the globe's aging population. Such diseases affect the nervous system and are characterized by a progressive decline in brain function and progressive cognitive impairment, decreasing the quality of life for those with the disease as well as for their families and loved ones. The increased burden of nervous system diseases demands a deeper insight into the biomolecular mechanisms at work during disease development in order to improve clinical diagnosis and drug design. Recently, evidence has related glycosylation to nervous system diseases. Glycosylation is a vital post-translational modification that mediates many biological functions, and aberrant glycosylation has been associated with a variety of diseases. Thus, the investigation of glycosylation in neurological diseases could provide novel biomarkers and information for disease pathology. During the last decades, many techniques have been developed for facilitation of reliable and efficient glycomic analysis. Among these, mass spectrometry (MS) is considered the most powerful tool for glycan analysis due to its high resolution, high sensitivity, and the ability to acquire adequate structural information for glycan identification. Along with MS, a variety of approaches and strategies are employed to enhance the MS-based identification and quantitation of glycans in neurological samples. Here, we review the advanced glycomic tools used in nervous system disease studies, including separation techniques prior to MS, fragmentation techniques in MS, and corresponding strategies. The glycan markers in common clinical nervous system diseases discovered by utilizing such MS-based glycomic tools are also summarized and discussed.
Collapse
Affiliation(s)
- Wenjing Peng
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, United States
| | - Firas Kobeissy
- Program for Neurotrauma, Neuroproteomics and Biomarkers Research, Department of Emergency Medicine, University of Florida, Gainesville, FL, United States
| | - Stefania Mondello
- Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Messina, Italy
| | - Chloe Barsa
- Program for Neurotrauma, Neuroproteomics and Biomarkers Research, Department of Emergency Medicine, University of Florida, Gainesville, FL, United States
| | - Yehia Mechref
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, TX, United States
| |
Collapse
|
4
|
Hamilton ES, Ganjalizadeh V, Wright JG, Pitt WG, Schmidt H, Hawkins AR. 3D hydrodynamic focusing in microscale channels formed with two photoresist layers. MICROFLUIDICS AND NANOFLUIDICS 2019; 23:122. [PMID: 35664662 PMCID: PMC9162057 DOI: 10.1007/s10404-019-2293-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Accepted: 10/09/2019] [Indexed: 06/01/2023]
Abstract
3D hydrodynamic focusing was implemented with channel cross-section dimensions smaller than 10 μm. Microchannels were formed using sacrificial etching of two photoresist layers on a silicon wafer. The photoresist forms a plus-shaped prismatic focusing fluid junction which was coated with plasma-enhanced chemical-vapor-deposited oxide. Buffer fluid carried to the focusing junction envelopes an intersecting sample fluid, resulting in 3D focusing of the sample stream. The design requires four fluid ports and operates across a wide range of fluid velocities through pressure-driven flow. The focusing design was integrated with optical waveguides to interrogate fluorescing particles and confirm 3D focusing. Particle diffusion away from a focused stream was characterized.
Collapse
Affiliation(s)
- Erik S. Hamilton
- Electrical and Computer Engineering, Brigham Young University, 450 Engineering Building, Provo, UT 84602, USA
| | - Vahid Ganjalizadeh
- Electrical and Computer Engineering, University of California, Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA
| | - Joel G. Wright
- Electrical and Computer Engineering, Brigham Young University, 450 Engineering Building, Provo, UT 84602, USA
| | - William G. Pitt
- Chemical Engineering, Brigham Young University, 330 Engineering Building, Provo, UT 84602, USA
| | - Holger Schmidt
- Electrical and Computer Engineering, University of California, Santa Cruz, 1156 High Street, Santa Cruz, CA 95064, USA
| | - Aaron R. Hawkins
- Electrical and Computer Engineering, Brigham Young University, 450 Engineering Building, Provo, UT 84602, USA
| |
Collapse
|
5
|
Meng ZJ, Wang W, Liang X, Zheng WC, Deng NN, Xie R, Ju XJ, Liu Z, Chu LY. Plug-n-play microfluidic systems from flexible assembly of glass-based flow-control modules. LAB ON A CHIP 2015; 15:1869-78. [PMID: 25711675 DOI: 10.1039/c5lc00132c] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
In this study, we report on a simple and versatile plug-n-play microfluidic system that is fabricated from flexible assembly of glass-based flow-control modules for flexibly manipulating flows for versatile emulsion generation. The microfluidic system consists of three basic functional units: a flow-control module, a positioning groove, and a connection fastener. The flow-control module that is based on simple assembly of low-cost glass slides, coverslips, and glass capillaries provides excellent chemical resistance and optical properties, and easy wettability modification for flow manipulation. The flexible combination of the flow-control modules with 3D-printed positioning grooves and connection fasteners enables creation of versatile microfluidic systems for generating various higher-order multiple emulsions. The simple and reversible connection of the flow-control modules also allows easy disassembly of the microfluidic systems for further scale-up and functionalization. We demonstrate the scalability and controllability of flow manipulation by creating microfluidic systems from flexible assembly of flow-control modules for controllable generation of multiple emulsions from double emulsions to quadruple emulsions. Meanwhile, the flexible flow manipulation in the flow-control module provides advanced functions for improved control of the drop size, and for controllable generation of drops containing distinct components within multiple emulsions to extend the emulsion structure. Such modular microfluidic systems provide flexibility and versatility to flexibly manipulate micro-flows for enhanced and extended applications.
Collapse
Affiliation(s)
- Zhi-Jun Meng
- School of Chemical Engineering, Sichuan University, Chengdu, Sichuan 610065, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Experimental and numerical analysis of high-resolution injection technique for capillary electrophoresis microchip. Int J Mol Sci 2011; 12:3594-605. [PMID: 21747696 PMCID: PMC3131580 DOI: 10.3390/ijms12063594] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2011] [Revised: 05/11/2011] [Accepted: 05/25/2011] [Indexed: 12/15/2022] Open
Abstract
This study presents an experimental and numerical investigation on the use of high-resolution injection techniques to deliver sample plugs within a capillary electrophoresis (CE) microchip. The CE microfluidic device was integrated into a U-shaped injection system and an expansion chamber located at the inlet of the separation channel, which can miniize the sample leakage effect and deliver a high-quality sample plug into the separation channel so that the detection performance of the device is enhanced. The proposed 45° U-shaped injection system was investigated using a sample of Rhodamine B dye. Meanwhile, the analysis of the current CE microfluidic chip was studied by considering the separation of Hae III digested ϕx-174 DNA samples. The experimental and numerical results indicate that the included 45° U-shaped injector completely eliminates the sample leakage and an expansion separation channel with an expansion ratio of 2.5 delivers a sample plug with a perfect detection shape and highest concentration intensity, hence enabling an optimal injection and separation performance.
Collapse
|
7
|
Fu LM, Hong TF, Wen CY, Tsai CH, Lin CH. Electrokinetic instability effects in microchannels with and without nanofilm coatings. Electrophoresis 2009; 29:4871-9. [PMID: 19130549 DOI: 10.1002/elps.200800455] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
This paper presents a parametric experimental investigation into the electrokinetic instability (EKI) phenomenon within three different types of microfluidic device, namely T-type, cross-shaped, and cross-form with an expansion configuration. The critical electric field strength at which the EKI phenomenon is induced is examined as a function of the conductivity ratio, the microchannel width, the expansion ratio, and the surface treatment of the microchannel walls. It is found that the critical electric field strength associated with the onset of EKI is strongly dependent on the conductivity ratio of the two samples within the microfluidic device and reduces as the channel width increases. The surfaces of the microchannel walls are coated with hydrophilic or hydrophobic organic-based spin-on-glass (SOG) nanofilms for glass-based microchips. The experimental results indicate that no significant difference exists in the critical electric field strengths in the hydrophilic or hydrophobic SOG-coated microchannels, respectively. However, for a given conductivity ratio and microchannel width, the critical strength of the electric field is slightly lower in the SOG-coated microchannels than in the non-coated channels. In general, the results presented in this study demonstrate the potential for designing and controlling on-chip assays requiring the manipulation of samples with high conductivity gradients, and provide a useful general reference for avoiding EKI effects in capillary electrophoresis analysis applications.
Collapse
Affiliation(s)
- Lung-Ming Fu
- Department of Materials Engineering, National Pingtung University of Science and Technology, Pingtung, Taiwan
| | | | | | | | | |
Collapse
|
8
|
Chang CL, Hou HH, Fu LM, Tsai CH. A low-leakage sample plug injection scheme for crossform microfluidic capillary electrophoresis devices incorporating a restricted cross-channel intersection. Electrophoresis 2008; 29:3135-44. [PMID: 18600833 DOI: 10.1002/elps.200800022] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This study develops a crossform CE microfluidic device in which a single-circular barrier or a double-circular barrier is introduced at the cross-channel intersection. Utilizing a conventional crossform injection scheme, it is shown that these barriers reduce sample leakage and deliver a compact sample band into the separation channel, thereby ensuring an enhanced detection performance. A series of numerical and experimental investigations are performed to investigate the effects of the barrier type and the barrier ratio on the flow streamlines within the microchannel and to clarify their respective effects on the sample leakage ratio and sample plug variance during the injection process. The results indicate that a single-circular barrier injector with a barrier ratio greater than 20% and a double-circular barrier injector with a barrier ratio greater than 40% minimize the sample leakage ratio and produce a compact sample plug. As a result, both injectors have an excellent potential for use in high-quality, high-throughput chemical analysis procedures and in many other applications throughout the micro-total analysis systems field.
Collapse
Affiliation(s)
- Chin-Lung Chang
- Department of Vehicle Engineering, National Pingtung University of Science and Technology, Pingtung, Taiwan
| | | | | | | |
Collapse
|
9
|
West J, Becker M, Tombrink S, Manz A. Micro Total Analysis Systems: Latest Achievements. Anal Chem 2008; 80:4403-19. [PMID: 18498178 DOI: 10.1021/ac800680j] [Citation(s) in RCA: 351] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Jonathan West
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | - Marco Becker
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | - Sven Tombrink
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| | - Andreas Manz
- ISAS, Institute for Analytical Sciences, Bunsen-Kirchhoff-Strasse 11, D-44139 Dortmund, Germany
| |
Collapse
|