1
|
Martinier I, Trichet L, Fernandes FM. Biomimetic tubular materials: from native tissues to a unifying view of new vascular, tracheal, gastrointestinal, oesophageal, and urinary grafts. Chem Soc Rev 2025; 54:790-826. [PMID: 39606835 DOI: 10.1039/d4cs00429a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2024]
Abstract
Repairing tubular tissues-the trachea, the esophagus, urinary and gastrointestinal tracts, and the circulatory system-from trauma or severe pathologies that require resection, calls for new, more effective graft materials. Currently, the relatively narrow family of materials available for these applications relies on synthetic polymers that fail to reproduce the biological and physical cues found in native tissues. Mimicking the structure and the composition of native tubular tissues to elaborate functional grafts is expected to outperform the materials currently in use, but remains one of the most challenging goals in the field of biomaterials. Despite their apparent diversity, tubular tissues share extensive compositional and structural features. Here, we assess the current state of the art through a dual layer model, reducing each tissue to an inner epithelial layer and an outer muscular layer. Based on this model, we examine the current strategies developed to mimic each layer and we underline how each fabrication method stands in providing a biomimetic material for future clinical translation. The analysis provided here, addressed to materials chemists, biomaterials engineers and clinical staff alike, sets new guidelines to foster the elaboration of new biomimetic materials for effective tubular tissue repair.
Collapse
Affiliation(s)
- Isabelle Martinier
- Laboratoire de Chimie de la Matière Condensée de Paris, Sorbonne Université, UMR 7574, Paris 75005, France.
| | - Léa Trichet
- Laboratoire de Chimie de la Matière Condensée de Paris, Sorbonne Université, UMR 7574, Paris 75005, France.
| | - Francisco M Fernandes
- Laboratoire de Chimie de la Matière Condensée de Paris, Sorbonne Université, UMR 7574, Paris 75005, France.
| |
Collapse
|
2
|
Maquignaz G, Zoll R, Karpelson M, Weaver JC, Wood RJ. Design and fabrication of a parasite-inspired, millimeter-scale tissue anchoring mechanism. PNAS NEXUS 2024; 3:pgae495. [PMID: 39712070 PMCID: PMC11660956 DOI: 10.1093/pnasnexus/pgae495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Accepted: 10/05/2024] [Indexed: 12/24/2024]
Abstract
Optimizing mechanical adhesion to specific human tissue types is a field of research that has gained increasing attention over the past two decades due to its utility for diagnostics, therapeutics, and surgical device design. This is especially relevent for medical devices, which could benefit from the presence of attachment mechanisms in order to better target-specific regions of the gastrointestinal (GI) tract or other soft tissues for sensing, sample collection, and drug release. In this work, and inspired by the tissue anchoring adaptations found in diverse parasitic taxa, we present a design and manufacturing platform for the production of a nonintuitive bioinspired millimeter-scale articulated attachment mechanism using laminate fabrication techniques. The functional design closely mimics the geometry and motions of curved hooks employed by some species of tapeworms to attach to their host's intestinal walls. Here, we show the feasibility of such a mechanism both in terms of attachment capabilities and manufacturability. Successful attachment of a prototype to tissue-simulating synthetic medical hydrogels is demonstrated with an adhesion force limited only by the ultimate strength of the tissue. These results demonstrate the efficacy of parasite-inspired deployable designs as an alternative to, or complement to, existing tissue attachment mechanisms. We also describe the design and manufacturing process workflow and provide insights for scaling the design for mass-production.
Collapse
Affiliation(s)
- Gabriel Maquignaz
- Harvard John A. Paulson School of Engineering and Applied Science, Harvard University, Cambridge, MA 02139, USA
- École Polytechnique Fédérale de Lausanne (EPFL), Institute of Electrical and Micro Engineering, Lausanne CH-1015, Vaud, Switzerland
| | - Rachel Zoll
- Harvard John A. Paulson School of Engineering and Applied Science, Harvard University, Cambridge, MA 02139, USA
| | - Michael Karpelson
- Harvard John A. Paulson School of Engineering and Applied Science, Harvard University, Cambridge, MA 02139, USA
| | - James C Weaver
- Harvard John A. Paulson School of Engineering and Applied Science, Harvard University, Cambridge, MA 02139, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02215, USA
| | - Robert J Wood
- Harvard John A. Paulson School of Engineering and Applied Science, Harvard University, Cambridge, MA 02139, USA
| |
Collapse
|
3
|
Naik DA, Matonis S, Balakrishnan G, Bettinger CJ. Intestinal retentive systems - recent advances and emerging approaches. J Mater Chem B 2023; 12:64-78. [PMID: 38047746 DOI: 10.1039/d3tb01842c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2023]
Abstract
Intestinal retentive devices (IRDs) are devices designed to anchor within the lumen of the intestines for long-term residence in the gastrointestinal tract. IRDs can enable impactful medical device technologies including sustained oral drug delivery systems, indwelling sensors, or real-time diagnostics. The design and testing of IRDs present a myriad of challenges, including precise deployment of the device at desired intestinal locations, secure anchoring within the gastrointestinal tract to allow for natural function, and safe removal of the IRD at user-defined times. Advancing the state-of-the-art of IRD is an interdisciplinary effort that requires innovations such as new materials, novel anchoring mechanisms, and medical device design with consistent input from clinical practitioners and end-users. This perspective briefly reviews the current state-of-the-art for IRDs and charts a path forward to inform the design of future concepts. Specifically, this article will highlight materials, retention mechanisms, and test beds to measure the efficacy of IRDs and their mechanisms. Finally, potential synergies between IRD and other medical device technologies are presented to identify future opportunities.
Collapse
Affiliation(s)
- Durva A Naik
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Wean Hall 3325, Pittsburgh, PA 15213, USA.
| | - Spencer Matonis
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Wean Hall 3325, Pittsburgh, PA 15213, USA.
| | - Gaurav Balakrishnan
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Wean Hall 3325, Pittsburgh, PA 15213, USA.
| | - Christopher J Bettinger
- Materials Science and Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Wean Hall 3325, Pittsburgh, PA 15213, USA.
- Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Scott Hall 4N201, Pittsburgh, PA 15213, USA
| |
Collapse
|
4
|
Naik D, Balakrishnan G, Rajagopalan M, Huang X, Trivedi N, Bhat A, Bettinger CJ. Villi Inspired Mechanical Interlocking for Intestinal Retentive Devices. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2301084. [PMID: 37449425 PMCID: PMC10602537 DOI: 10.1002/advs.202301084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 06/08/2023] [Indexed: 07/18/2023]
Abstract
Intestinal retentive devices have applications ranging from sustained oral drug delivery systems to indwelling ingestible medical devices. Current strategies to retain devices in the small intestine primarily focus on chemical anchoring using mucoadhesives or mechanical coupling using expandable devices or structures that pierce the intestinal epithelium. Here, the feasibility of intestinal retention using devices containing villi-inspired structures that mechanically interlock with natural villi of the small intestine is evaluated. First the viability of mechanical interlocking as an intestinal retention strategy is estimated by estimating the resistance to peristaltic shear between simulated natural villi and devices with various micropost geometries and parameters. Simulations are validated in vitro by fabricating micropost array patches via multistep replica molding and performing lap-shear tests to evaluate the interlocking performance of the fabricated microposts with artificial villi. Finally, the optimal material and design parameters of the patches that can successfully achieve retention in vivo are predicted. This study represents a proof-of-concept for the viability of micropost-villi mechanical interlocking strategy to develop nonpenetrative multifunctional intestinal retentive devices for the future.
Collapse
Affiliation(s)
- Durva Naik
- Materials Science and Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Wean Hall, 3325PittsburghPA15213USA
| | - Gaurav Balakrishnan
- Materials Science and Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Wean Hall, 3325PittsburghPA15213USA
| | - Mahathy Rajagopalan
- Biomedical Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Scott Hall, 4N201PittsburghPA15213USA
| | - Xiaozili Huang
- Materials Science and Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Wean Hall, 3325PittsburghPA15213USA
| | - Nihar Trivedi
- Materials Science and Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Wean Hall, 3325PittsburghPA15213USA
| | - Arnav Bhat
- Biomedical Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Scott Hall, 4N201PittsburghPA15213USA
| | - Christopher J. Bettinger
- Materials Science and Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Wean Hall, 3325PittsburghPA15213USA
- Biomedical Engineering DepartmentCarnegie Mellon University5000 Forbes Avenue, Scott Hall, 4N201PittsburghPA15213USA
| |
Collapse
|
5
|
Van de Steene T, Tanghe E, Martens L, Garripoli C, Stanzione S, Joseph W. Optimal Frequency and Wireless Power Budget for Miniature Receivers in Obese People. SENSORS (BASEL, SWITZERLAND) 2023; 23:8084. [PMID: 37836914 PMCID: PMC10574982 DOI: 10.3390/s23198084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/19/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023]
Abstract
This study investigates wireless power transfer for deep in-body receivers, determining the optimal frequency, power budget, and design for the transmitter and receiver. In particular, the focus is on small, in-body receivers at large depths up to 20 cm for obese patients. This enables long-term monitoring of the gastrointestinal tract for all body types. Numerical simulations are used to investigate power transfer and losses as a function of frequency and to find the optimal design at the selected frequency for an obese body model. From all ISM-frequencies in the investigated range (1 kHz-10 GHz), the value of 13.56 MHz yields the best performance. This optimum corresponds to the transition from dominant copper losses in conductors to dominant losses in conductive tissue. At this frequency, a transmitting and receiving coil are designed consisting of 12 and 23 windings, respectively. With a power transfer efficiency of 2.70×10-5, 18 µW can be received for an input power of 0.68 W while still satisfying exposure guidelines. The power transfer is validated by measurements. For the first time, efficiency values and the power budget are reported for WPT through 20 cm of tissue to mm sized receivers. Compared to WPT at higher frequencies, as commonly used for small receivers, the proposed system is more suitable for WPT to large depths in-body and comes with the advantage that no focusing is required, which can accommodate multiple receivers and uncertainty about receiver location more easily. The received power allows long-term sensing in the gastrointestinal tract by, e.g., temperature, pressure, and pH sensors, motility sensing, or even gastric stimulation.
Collapse
Affiliation(s)
- Tom Van de Steene
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | - Emmeric Tanghe
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | - Luc Martens
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| | | | | | - Wout Joseph
- Department of Information Technology, Ghent University/imec, B-9052 Ghent, Belgium
| |
Collapse
|
6
|
Ramadi KB, McRae JC, Selsing G, Su A, Fernandes R, Hickling M, Rios B, Babaee S, Min S, Gwynne D, Jia NXJ, Aragon A, Ishida K, Kuosmanen J, Jenkins J, Hayward A, Kamrin K, Traverso G. Bioinspired, ingestible electroceutical capsules for hunger-regulating hormone modulation. Sci Robot 2023; 8:eade9676. [PMID: 37099636 PMCID: PMC10508349 DOI: 10.1126/scirobotics.ade9676] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 03/29/2023] [Indexed: 04/28/2023]
Abstract
The gut-brain axis, which is mediated via enteric and central neurohormonal signaling, is known to regulate a broad set of physiological functions from feeding to emotional behavior. Various pharmaceuticals and surgical interventions, such as motility agents and bariatric surgery, are used to modulate this axis. Such approaches, however, are associated with off-target effects or post-procedure recovery time and expose patients to substantial risks. Electrical stimulation has also been used to attempt to modulate the gut-brain axis with greater spatial and temporal resolution. Electrical stimulation of the gastrointestinal (GI) tract, however, has generally required invasive intervention for electrode placement on serosal tissue. Stimulating mucosal tissue remains challenging because of the presence of gastric and intestinal fluid, which can influence the effectiveness of local luminal stimulation. Here, we report the development of a bioinspired ingestible fluid-wicking capsule for active stimulation and hormone modulation (FLASH) capable of rapidly wicking fluid and locally stimulating mucosal tissue, resulting in systemic modulation of an orexigenic GI hormone. Drawing inspiration from Moloch horridus, the "thorny devil" lizard with water-wicking skin, we developed a capsule surface capable of displacing fluid. We characterized the stimulation parameters for modulation of various GI hormones in a porcine model and applied these parameters to an ingestible capsule system. FLASH can be orally administered to modulate GI hormones and is safely excreted with no adverse effects in porcine models. We anticipate that this device could be used to treat metabolic, GI, and neuropsychiatric disorders noninvasively with minimal off-target effects.
Collapse
Affiliation(s)
- Khalil B Ramadi
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Engineering, New York University Abu Dhabi, Abu Dhabi, UAE
- Tandon School of Engineering, New York University, New York, NY, USA
| | - James C McRae
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - George Selsing
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Arnold Su
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Rafael Fernandes
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Maela Hickling
- Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Brandon Rios
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Sahab Babaee
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Seokkee Min
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Declan Gwynne
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Neil Xi-Juna Jia
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Aleyah Aragon
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Keiko Ishida
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Johannes Kuosmanen
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Josh Jenkins
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Alison Hayward
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Comparative Medicine, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Ken Kamrin
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA 02115, USA
- David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
7
|
Wu L, Lu K. Experimental investigation of a new type of driving concept for capsule robot. INTEL SERV ROBOT 2022. [DOI: 10.1007/s11370-022-00443-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
Sarker S, Wankum B, Perey T, Mau MM, Shimizu J, Jones R, Terry B. A Novel Capsule-Delivered Enteric Drug-Injection Device for Delivery of Systemic Biologics: A Pilot Study in a Porcine Model. IEEE Trans Biomed Eng 2021; 69:1870-1879. [PMID: 34807818 DOI: 10.1109/tbme.2021.3129653] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Innovative swallowable capsule technologies such as drug-loaded, dissolvable microneedles, mucoadhesive patches, and various microdevices present unique drug-carrying capabilities to overcome challenges regarding oral delivery of biologics. Here, we report a swallowable capsule for intestinal drug delivery (SCIDD) with the potential of directly injecting biological therapeutics into the insensate small intestine wall. The design, optimization, and validation of the SCIDD's primary subsystems were performed both ex-vivo and in-vivo. The assembled capsule was further tested in vivo to validate the actuation sequence and showed a 70% (n=17) success rate in an animal model. Additionally, a drug delivery study indicated systemic uptake of adalimumab via SCIDD compared with luminal delivery in the small intestine. The pilot study presented here establishes that the novel platform could be used to orally deliver systemic biologics.
Collapse
|
9
|
Smart pills for gastrointestinal diagnostics and therapy. Adv Drug Deliv Rev 2021; 177:113931. [PMID: 34416311 DOI: 10.1016/j.addr.2021.113931] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 08/03/2021] [Accepted: 08/13/2021] [Indexed: 12/13/2022]
Abstract
Ingestible smart pills have the potential to be a powerful clinical tool in the diagnosis and treatment of gastrointestinal disease. Though examples of this technology, such as capsule endoscopy, have been successfully translated from the lab into clinically used products, there are still numerous challenges that need to be overcome. This review gives an overview of the research being done in the area of ingestible smart pills and reports on the technical challenges in this field.
Collapse
|
10
|
Sarker S, Wankum B, Shimizu J, Jones R, Terry B. A Factorial Approach for Optimizing the Design Parameters of a Tissue Attachment Mechanism for Drug Delivery. IEEE Trans Biomed Eng 2021; 69:32-41. [PMID: 34097601 DOI: 10.1109/tbme.2021.3086975] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Biological macromolecule drugs or biologics are not suited for commonly preferred oral delivery due to their intrinsic instability and physical, chemical, or immunological barriers to the gastrointestinal tract. Ingestible capsule robots (ICR) have become a versatile platform, including use for drug delivery applications for various gastrointestinal pathologies with future potential for systemic drug delivery. In this work, a tissue attachment mechanism (TAM) for a drug delivery ICR is introduced that can facilitate a non-invasive systemic delivery of unaltered biologics via direct injection through the insensate layers of the small intestine. The main prerequisite for achieving systemic drug delivery via this device is to have strong tissue attachment of the TAM. This study aimed to optimize the attachment success rate for drug delivery and characterize attachment duration in vivo. A fractional factorial approach was used in vivo to identify and optimize factors that most influence attachment of the TAM to maximize attachment rate. Multiple in vivo optimization levels were performed using the small intestine of anesthetized pigs, and an attachment success rate of 92% was achieved. Optimal TAMs were surgically placed in vivo to determine the duration of attachment following anesthetization and surgery recovery. The average in vivo attachment duration was 32.29.4 hours. This work establishes a device for consistent and reliable attachment duration, making the TAM a suitable candidate for a 24-hour systemic drug delivery platform.
Collapse
|
11
|
Ramadi KB, Srinivasan SS, Traverso G. Electroceuticals in the Gastrointestinal Tract. Trends Pharmacol Sci 2020; 41:960-976. [PMID: 33127099 PMCID: PMC8186669 DOI: 10.1016/j.tips.2020.09.014] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Revised: 09/25/2020] [Accepted: 09/30/2020] [Indexed: 02/08/2023]
Abstract
The field of electroceuticals has attracted considerable attention over the past few decades as a novel therapeutic modality. The gastrointestinal (GI) tract (GIT) holds significant potential as a target for electroceuticals as the intersection of neural, endocrine, and immune systems. We review recent developments in electrical stimulation of various portions of the GIT (including esophagus, stomach, and small and large intestine) and nerves projecting to the GIT and supportive organs. This has been tested with varying degrees of success for several dysmotility, inflammatory, hormonal, and neurologic disorders. We outline a vision for the future of GI electroceuticals, building on advances in mechanistic understanding of GI physiology coupled with novel ingestible technologies. The next wave of electroceutical therapies will be minimally invasive and more targeted than current approaches, making them an indispensable tool in the clinical armamentarium.
Collapse
Affiliation(s)
- Khalil B Ramadi
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Shriya S Srinivasan
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA; David H. Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| |
Collapse
|
12
|
Abstract
Wireless capsule endoscopy (WCE) is noninvasive, painless, and riskless on detection for gastrointestinal disease. It attracts increasing attention. Wireless power transfer (WPT) technology is utilized to supply power for WCE. Receiving coil (RC) of WPT is capsulated into WCE. Its position and direction change all through gastrointestinal tract. Transmitting coil (TC) is worn by the patient. So the mutual inductance varies all the time. It should be studied to ensure sufficient receiving power. However, existing analytical methods do not reach satisfactory accuracy. They can only solve simple cases with positional misalignment. Numerical simulation models are time-consuming. Furthermore, an entirely new simulation must be repeated when any change in alignment occurs. Thus, based on geometry and misalignment of RC and TC, a model for mutual inductance is proposed. Compared with analytical methods, it is applicable to not only circular and rectangular RC, but also the elliptic, with directional misalignment. It costs below 0.1% of computational time of the simulation for the same accuracy. Moreover, any change in misalignment is easily handled by a simple change of parameter in the model. It reaches a tradeoff between computational accuracy and time. Receiving power is evaluated rapidly and accurately with proposed model.
Collapse
Affiliation(s)
- Shuai Kuang
- Department of Precise Medical Engineering and Intelligent Electronic Microsystems, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China.
| | - Guozheng Yan
- Department of Precise Medical Engineering and Intelligent Electronic Microsystems, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
13
|
Stilli A, Dimitrakakis E, D'Ettorre C, Tran M, Stoyanov D. Pneumatically Attachable Flexible Rails for Track-Guided Ultrasound Scanning in Robotic-Assisted Partial Nephrectomy—A Preliminary Design Study. IEEE Robot Autom Lett 2019. [DOI: 10.1109/lra.2019.2894499] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
14
|
Advances in Penetrating Multichannel Microelectrodes Based on the Utah Array Platform. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2019; 1101:1-40. [PMID: 31729670 DOI: 10.1007/978-981-13-2050-7_1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
The Utah electrode array (UEA) and its many derivatives have become a gold standard for high-channel count bi-directional neural interfaces, in particular in human subject applications. The chapter provides a brief overview of leading electrode concepts and the context in which the UEA has to be understood. It goes on to discuss the key advances and developments of the UEA platform in the past 15 years, as well as novel wireless and system integration technologies that will merge into future generations of fully integrated devices. Aspects covered include novel device architectures that allow scaling of channel count and density of electrode contacts, material improvements to substrate, electrode contacts, and encapsulation. Further subjects are adaptations of the UEA platform to support IR and optogenetic simulation as well as an improved understanding of failure modes and methods to test and accelerate degradation in vitro such as to better predict device failure and lifetime in vivo.
Collapse
|
15
|
Abstract
In this study, we propose a new magnetically actuated anchoring system for wireless capsule endoscopes (WCE) by employing the principle of a switchable magnetic spring. A force model is derived to predict the magnetic force needed to support the interaction between the anchors and the intestinal lumen. The theoretical and experimental analysis conducted shows that the magnetic spring is capable of providing the force needed to activate the anchoring mechanism, which consists of four foldable legs. A prototype capsule with a size comparable with the size of a commercial WCE was designed, fabricated, and tested. The in-vitro tests with a real small intestine show that the proposed anchoring mechanism is able to raise the friction force between the anchoring legs and inner wall of the intestine by more than two times after its activation using an external magnetic field. Experimental results presented demonstrate that the proposed anchoring system, which has a low foot-print not taking up too much space on the capsule, can provide a reliable anchoring capability with the capsule inside the intestinal lumen.
Collapse
|
16
|
Xie W, Lewis WM, Kaser J, Ross Welch C, Li P, Nelson CA, Kothari V, Terry BS. Design and Validation of a Biosensor Implantation Capsule Robot. J Biomech Eng 2017; 139:2625660. [DOI: 10.1115/1.4036607] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Indexed: 12/22/2022]
Abstract
We have proposed a long-term, noninvasive, nonrestrictive method of delivering and implanting a biosensor within the body via a swallowable implantation capsule robot (ICR). The design and preliminary validation of the ICR’s primary subsystem—the sensor deployment system—is discussed and evidence is provided for major design choices. The purpose of the sensor deployment system is to adhere a small biosensor to the mucosa of the intestine long-term, and the modality was inspired by tapeworms and other organisms that employ a strategy of mechanical adhesion to soft tissue via the combined use of hooks or needles and suckers. Testing was performed to refine the design of the suction and needle attachment as well as the sensor ejection features of the ICR. An experiment was conducted in which needle sharpness, needle length, and vacuum volume were varied, and no statistically significant difference was observed. Finally, preliminary testing, coupled with prior work within a live porcine model, provided evidence that this is a promising approach for implanting a biosensor within the small intestine.
Collapse
Affiliation(s)
- Wanchuan Xie
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526
| | - Weston M. Lewis
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526
| | - Jared Kaser
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526
| | - C. Ross Welch
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526
| | - Pengbo Li
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526
| | - Carl A. Nelson
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526
| | - Vishal Kothari
- Department of Surgery, University of Nebraska Medical Center, 4400 Emile Street, Omaha, NE 68198
| | - Benjamin S. Terry
- Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, W342 Nebraska Hall, Lincoln, NE 68588-0526 e-mail:
| |
Collapse
|