1
|
Sartoretti E, Gennari AG, Maurer A, Sartoretti T, Skawran S, Schwyzer M, Rossi A, Giannopoulos AA, Buechel RR, Gebhard C, Huellner MW, Messerli M. Opportunistic deep learning powered calcium scoring in oncologic patients with very high coronary artery calcium (≥ 1000) undergoing 18F-FDG PET/CT. Sci Rep 2022; 12:19191. [PMID: 36357446 PMCID: PMC9649723 DOI: 10.1038/s41598-022-20005-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 09/07/2022] [Indexed: 11/11/2022] Open
Abstract
Our aim was to identify and quantify high coronary artery calcium (CAC) with deep learning (DL)-powered CAC scoring (CACS) in oncological patients with known very high CAC (≥ 1000) undergoing 18F-FDG-PET/CT for re-/staging. 100 patients were enrolled: 50 patients with Agatston scores ≥ 1000 (high CACS group), 50 patients with Agatston scores < 1000 (negative control group). All patients underwent oncological 18F-FDG-PET/CT and cardiac SPECT myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin within 6 months. CACS was manually performed on dedicated non-contrast ECG-gated CT scans obtained from SPECT-MPI (reference standard). Additionally, CACS was performed fully automatically with a user-independent DL-CACS tool on non-contrast, free-breathing, non-gated CT scans from 18F-FDG-PET/CT examinations. Image quality and noise of CT scans was assessed. Agatston scores obtained by manual CACS and DL tool were compared. The high CACS group had Agatston scores of 2200 ± 1620 (reference standard) and 1300 ± 1011 (DL tool, average underestimation of 38.6 ± 26%) with an intraclass correlation of 0.714 (95% CI 0.546, 0.827). Sufficient image quality significantly improved the DL tool's capability of correctly assigning Agatston scores ≥ 1000 (p = 0.01). In the control group, the DL tool correctly assigned Agatston scores < 1000 in all cases. In conclusion, DL-based CACS performed on non-contrast free-breathing, non-gated CT scans from 18F-FDG-PET/CT examinations of patients with known very high (≥ 1000) CAC underestimates CAC load, but correctly assigns an Agatston scores ≥ 1000 in over 70% of cases, provided sufficient CT image quality. Subgroup analyses of the control group showed that the DL tool does not generate false-positives.
Collapse
Affiliation(s)
- Elisabeth Sartoretti
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Antonio G. Gennari
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Alexander Maurer
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Thomas Sartoretti
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Stephan Skawran
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Moritz Schwyzer
- grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland ,grid.412004.30000 0004 0478 9977Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland ,grid.5801.c0000 0001 2156 2780Health Sciences and Technology, Institute of Food, Nutrition and Health, ETH Zurich, Zurich, Switzerland
| | - Alexia Rossi
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Andreas A. Giannopoulos
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Ronny R. Buechel
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Catherine Gebhard
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland ,grid.7400.30000 0004 1937 0650Center for Molecular Cardiology, University of Zurich, Zurich, Switzerland
| | - Martin W. Huellner
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| | - Michael Messerli
- grid.412004.30000 0004 0478 9977Department of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091 Zurich, Switzerland ,grid.7400.30000 0004 1937 0650University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Zhang L, Li L, Feng G, Fan T, Jiang H, Wang Z. Advances in CT Techniques in Vascular Calcification. Front Cardiovasc Med 2021; 8:716822. [PMID: 34660718 PMCID: PMC8511450 DOI: 10.3389/fcvm.2021.716822] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 08/30/2021] [Indexed: 12/17/2022] Open
Abstract
Vascular calcification, a common pathological phenomenon in atherosclerosis, diabetes, hypertension, and other diseases, increases the incidence and mortality of cardiovascular diseases. Therefore, the prevention and detection of vascular calcification play an important role. At present, various techniques have been applied to the analysis of vascular calcification, but clinical examination mainly depends on non-invasive and invasive imaging methods to detect and quantify. Computed tomography (CT), as a commonly used clinical examination method, can analyze vascular calcification. In recent years, with the development of technology, in addition to traditional CT, some emerging types of CT, such as dual-energy CT and micro CT, have emerged for vascular imaging and providing anatomical information for calcification. This review focuses on the latest application of various CT techniques in vascular calcification.
Collapse
Affiliation(s)
- Lijie Zhang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Lihua Li
- Department of Pathology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Guoquan Feng
- Department of Radiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Tingpan Fan
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Han Jiang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Zhongqun Wang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| |
Collapse
|
3
|
Sun Z, Ng CKC, Wong YH, Yeong CH. 3D-Printed Coronary Plaques to Simulate High Calcification in the Coronary Arteries for Investigation of Blooming Artifacts. Biomolecules 2021; 11:biom11091307. [PMID: 34572520 PMCID: PMC8468360 DOI: 10.3390/biom11091307] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 08/26/2021] [Accepted: 08/31/2021] [Indexed: 11/16/2022] Open
Abstract
The diagnostic value of coronary computed tomography angiography (CCTA) is significantly affected by high calcification in the coronary arteries owing to blooming artifacts limiting its accuracy in assessing the calcified plaques. This study aimed to simulate highly calcified plaques in 3D-printed coronary models. A combination of silicone + 32.8% calcium carbonate was found to produce 800 HU, representing extensive calcification. Six patient-specific coronary artery models were printed using the photosensitive polyurethane resin and a total of 22 calcified plaques with diameters ranging from 1 to 4 mm were inserted into different segments of these 3D-printed coronary models. The coronary models were scanned on a 192-slice CT scanner with 70 kV, pitch of 1.4, and slice thickness of 1 mm. Plaque attenuation was measured between 1100 and 1400 HU. Both maximum-intensity projection (MIP) and volume rendering (VR) images (wide and narrow window widths) were generated for measuring the diameters of these calcified plaques. An overestimation of plaque diameters was noticed on both MIP and VR images, with measurements on the MIP images close to those of the actual plaque sizes (<10% deviation), and a large measurement discrepancy observed on the VR images (up to 50% overestimation). This study proves the feasibility of simulating extensive calcification in coronary arteries using a 3D printing technique to develop calcified plaques and generate 3D-printed coronary models.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA 6845, Australia;
- Curtin Health Innovation Research Institute (CHIRI), Faculty of Health Sciences, Curtin University, Perth, WA 6845, Australia
- Correspondence: ; Tel.: +61-8-9266-7509; Fax: +61-8-9266-2377
| | - Curtise Kin Cheung Ng
- Discipline of Medical Radiation Science, Curtin Medical School, Curtin University, Perth, WA 6845, Australia;
- Curtin Health Innovation Research Institute (CHIRI), Faculty of Health Sciences, Curtin University, Perth, WA 6845, Australia
| | - Yin How Wong
- Faculty of Health & Medical Sciences, School of Medicine, Taylor’s University, No. 1, Jalan Taylor’s, Subang Jaya 47500, Malaysia; (Y.H.W.); (C.H.Y.)
| | - Chai Hong Yeong
- Faculty of Health & Medical Sciences, School of Medicine, Taylor’s University, No. 1, Jalan Taylor’s, Subang Jaya 47500, Malaysia; (Y.H.W.); (C.H.Y.)
| |
Collapse
|
4
|
Juntunen MAK, Kotiaho AO, Nieminen MT, Inkinen SI. Optimizing iterative reconstruction for quantification of calcium hydroxyapatite with photon counting flat-detector computed tomography: a cardiac phantom study. J Med Imaging (Bellingham) 2021; 8:052102. [PMID: 33718518 PMCID: PMC7946398 DOI: 10.1117/1.jmi.8.5.052102] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Accepted: 01/28/2021] [Indexed: 11/28/2022] Open
Abstract
Purpose: Coronary artery calcium (CAC) scoring with computed tomography (CT) has been proposed as a screening tool for coronary artery disease, but concerns remain regarding the radiation dose of CT CAC scoring. Photon counting detectors and iterative reconstruction (IR) are promising approaches for patient dose reduction, yet the preservation of CAC scores with IR has been questioned. The purpose of this study was to investigate the applicability of IR for quantification of CAC using a photon counting flat-detector. Approach: We imaged a cardiac rod phantom with calcium hydroxyapatite (CaHA) inserts with different noise levels using an experimental photon counting flat-detector CT setup to simulate the clinical CAC scoring protocol. We applied filtered back projection (FBP) and two IR algorithms with different regularization strengths. We compared the air kerma values, image quality parameters [noise magnitude, noise power spectrum, modulation transfer function (MTF), and contrast-to-noise ratio], and CaHA quantification accuracy between FBP and IR. Results: IR regularization strength influenced CAC scores significantly ( p < 0.05 ). The CAC volumes and scores between FBP and IRs were the most similar when the IR regularization strength was chosen to match the MTF of the FBP reconstruction. Conclusion: When the regularization strength is selected to produce comparable spatial resolution with FBP, IR can yield comparable CAC scores and volumes with FBP. Nonetheless, at the lowest radiation dose setting, FBP produced more accurate CAC volumes and scores compared to IR, and no improved CAC scoring accuracy at low dose was demonstrated with the utilized IR methods.
Collapse
Affiliation(s)
- Mikael A. K. Juntunen
- University of Oulu, Research Unit of Medical Imaging, Physics, and Technology, Oulu, Finland
- Oulu University Hospital, Department of Diagnostic Radiology, Oulu, Finland
| | - Antti O. Kotiaho
- Oulu University Hospital, Department of Diagnostic Radiology, Oulu, Finland
| | - Miika T. Nieminen
- University of Oulu, Research Unit of Medical Imaging, Physics, and Technology, Oulu, Finland
- Oulu University Hospital, Department of Diagnostic Radiology, Oulu, Finland
- Medical Research Center, University of Oulu, Oulu University Hospital, Oulu, Finland
| | - Satu I. Inkinen
- University of Oulu, Research Unit of Medical Imaging, Physics, and Technology, Oulu, Finland
| |
Collapse
|
5
|
Pan YK, Sun MH, Wang JJ, Chen XB, Kan XJ, Ge YH, Guo ZP. Effect of different reconstruction algorithms on coronary artery calcium scores using the reduced radiation dose protocol: a clinical and phantom study. Quant Imaging Med Surg 2021; 11:1504-1517. [PMID: 33816187 DOI: 10.21037/qims-20-437] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Background This study aimed to evaluate the effects of different iterative reconstruction (IR) algorithms on coronary artery calcium (CAC) score quantification using the reduced radiation dose (RRD) protocol in an anthropomorphic phantom and in patients. Methods A thorax phantom, containing 9 calcification inserts with varying hydroxyapatite (HA) densities, was scanned with the reference protocol [120 kv, 80 mAs, filtered back projection (FBP)] and RRD protocol (120 kV, 20-80 mAs, 5 mAs interval) using a 256-slice computed tomography (CT) scanner. Raw data were reconstructed with different reconstruction algorithms [iDose4 levels 1-7 and iterative model reconstruction (IMR) levels 1-3]. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and Agatston score (AS) were calculated for each image series. The correction factor was derived from linear regression analysis between the reference image series and other image series with different parameters. Additionally, 40 patients were scanned with the RRD protocol (50 mAs) and reconstructed with FBP, iDose4 level 4, and IMR level 2. AS was calculated for the 3-group image series, and was corrected by applying a correction factor for the IMR group. The agreement of risk stratification with different reconstruction algorithms was also analyzed. Results For the phantom study, the iDose4 and IMR groups had significantly higher SNR and CNR than the FBP group (all P<0.05). There were no significant differences in the total AS after comparing image series reconstructed with iDose4 (level 1-7) and FBP (all P>0.05), while AS from the IMR (level 1-3) image series were lower than the FBP group (all P<0.05). The tube current of 50 mAs was determined for the clinical study, and the correction factor was 1.14. For the clinical study, the median AS from the iDose4 and IMR groups were both significantly lower compared to the FBP image series [(112.89 (63.01, 314.09), 113.22 (64.78, 364.95) vs. 118.59 (65.05, 374.48), both P<0.05]. After applying the correction factor, the adjusted AS from the IMR group was not significantly different from that of the FBP group [126.48 (69.62, 355.85) vs. 118.59 (65.05, 374.48), P=0.145]. Moreover, the agreement in risk stratification between FBP and IMR improved from 0.81 to 0.85. Conclusions The RRD CAC scoring scan using the IMR reconstruction algorithm is clinically feasible, and a correction factor can help reduce the AS underestimation effect.
Collapse
Affiliation(s)
- Yu-Kun Pan
- Department of Radiology, Central China Fuwai Hospital, People's Hospital of Zhengzhou University, Zhengzhou, China
| | - Ming-Hua Sun
- Department of Radiology, Henan Provincial People's Hospital, Department of Radiology of Central China Fuwai Hospital, Central China Fuwai Hospital of Zhengzhou University, Zhengzhou, China
| | - Jia-Jia Wang
- Department of Radiology, Central China Fuwai Hospital, People's Hospital of Zhengzhou University, Zhengzhou, China
| | | | - Xiao-Jing Kan
- Department of Radiology, Henan Provincial People's Hospital, Department of Radiology of Central China Fuwai Hospital, Central China Fuwai Hospital of Zhengzhou University, Zhengzhou, China
| | - Ying-Hui Ge
- Department of Radiology, Henan Provincial People's Hospital, Department of Radiology of Central China Fuwai Hospital, Central China Fuwai Hospital of Zhengzhou University, Zhengzhou, China
| | | |
Collapse
|
6
|
Tao S, Sheedy E, Bruesewitz M, Weber N, Williams K, Halaweish A, Schmidt B, Williamson E, McCollough C, Leng S. Technical Note: kV-independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction. Med Phys 2021; 48:1307-1314. [PMID: 33332626 DOI: 10.1002/mp.14663] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 12/04/2020] [Accepted: 12/08/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To determine the accuracy of CT number and calcium score of a kV-independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. METHODS Anthropomorphic chest phantoms were scanned on a third-generation dual-source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20-mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70-140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto-kV). Phantoms were also scanned at 120 kV using a size-dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. RESULTS The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto-kV provided a 25-34% dose reduction compared to AEC alone. CONCLUSION A kV-independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto-kV, this technique can reduce radiation by 25-34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
Collapse
Affiliation(s)
- Shengzhen Tao
- Department of Radiology, Mayo Clinic, Jacksonville, FL, USA
| | - Emily Sheedy
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Nikkole Weber
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Kyle Williams
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Bernhard Schmidt
- Siemens Healthineers, Siemensstraße 1, Forchheim, 91301, Germany
| | | | | | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
7
|
Steuwe A, Weber M, Bethge OT, Rademacher C, Boschheidgen M, Sawicki LM, Antoch G, Aissa J. Influence of a novel deep-learning based reconstruction software on the objective and subjective image quality in low-dose abdominal computed tomography. Br J Radiol 2021; 94:20200677. [PMID: 33095654 DOI: 10.1259/bjr.20200677] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. METHODS In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. RESULTS On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. CONCLUSION The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. ADVANCES IN KNOWLEDGE The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information.The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.
Collapse
Affiliation(s)
- Andrea Steuwe
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Marie Weber
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Oliver Thomas Bethge
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Christin Rademacher
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Matthias Boschheidgen
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Lino Morris Sawicki
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Gerald Antoch
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| | - Joel Aissa
- Department of Diagnostic and Interventional Radiology, University Dusseldorf, Medical Faculty, Dusseldorf, Germany
| |
Collapse
|
8
|
Sinogram-Affirmed Iterative Reconstruction Negatively Impacts the Risk Category Based on Agatston Score: A Study Combining Coronary Calcium Score Measurement and Coronary CT Angiography. BIOMED RESEARCH INTERNATIONAL 2020; 2020:6909130. [PMID: 32733949 PMCID: PMC7376420 DOI: 10.1155/2020/6909130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/24/2019] [Revised: 04/13/2020] [Accepted: 05/19/2020] [Indexed: 11/23/2022]
Abstract
Purpose To assess the impact of sinogram-affirmed iterative reconstruction (SAFIRE) on risk category for coronary artery disease by combining coronary calcium score measurement and coronary CT angiography (CCTA). Materials and Methods Eighty-nine patients (64.0% male) older than 18 years (64.4 ± 10.3 years) underwent coronary artery calcium scanning and prospectively ECG-triggered sequential CCTA examination. All raw data acquired in coronary artery calcium scanning were reconstructed by both filtered back projection (FBP) and SAFIRE algorithms with 5 different levels. Objective image quality and calcium quantification were evaluated and compared between FBP and all SAFIRE levels by the Sphericity Assumed test or Greenhouse-Geisser ε correction coefficient. Coronary artery stenosis was assessed in CCTA. Risk categories of all patients and of the patients with coronary artery stenosis in CCTA were compared between FBP and all SAFIRE levels by the Friedman test. Results The reconstruction protocol from traditional FBP to SAFIRE 5 was associated with a gradual reduction in CT value and image noise (P < 0.001) but associated with a gradual improvement in the signal-to-noise ratio (P < 0.001). There was a gradual reduction in coronary calcification quantification (Agatston score: from 73.5 in FBP to 38.1 in SAFIRE 5, P < 0.001) from traditional FBP to SAFIRE 5. There was a significant difference for the risk category between FBP and all levels of SAFIRE in all patients (from 3.5 in FBP to 3.2 in SAFIRE 5, P < 0.001) and in the patients with coronary artery stenosis in CCTA (from 4.0 in FBP to 3.6 in SAFIRE 5, P < 0.001). Conclusions SAFIRE significantly reduces coronary calcification quantification compared to FBP, resulting in the reduction of risk categories based on the Agatston score. The risk categories of the patients with coronary artery stenosis in CCTA may also decline. Thus, SAFIRE may lead risk categories to underestimate the existence of significant coronary artery stenosis.
Collapse
|
9
|
Best practice for the nuclear medicine technologist in CT-based attenuation correction and calcium score for nuclear cardiology. Eur J Hybrid Imaging 2020; 4:11. [PMID: 34191150 PMCID: PMC8218053 DOI: 10.1186/s41824-020-00080-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2019] [Accepted: 06/16/2020] [Indexed: 12/12/2022] Open
Abstract
The use of hybrid systems is increasingly growing in Europe and this is progressively important for the final result of diagnostic tests. As an integral part of the hybrid imaging system, computed tomography (CT) plays a crucial role in myocardial perfusion imaging diagnostics. Throughout Europe, a variety of equipment is available and also different university curricula of the nuclear medicine technologist are observed. Hence, the Technologist Committee of the European Association of Nuclear Medicine proposes to identify, through a bibliographic review, the recommendations for best practice in computed tomography applied to attenuation correction and calcium score in myocardial perfusion imaging, which courses in the set of knowledge, skills, and competencies for nuclear medicine technologists. This document aims at providing recommendations for CT acquisition protocols and CT image optimization in nuclear cardiology.
Collapse
|
10
|
Sun Z, Ng CKC, Squelch A. Synchrotron radiation computed tomography assessment of calcified plaques and coronary stenosis with different slice thicknesses and beam energies on 3D printed coronary models. Quant Imaging Med Surg 2019; 9:6-22. [PMID: 30788242 DOI: 10.21037/qims.2018.09.11] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Background To investigate the effect of different slice thicknesses and beam energies on the visualization and assessment of coronary artery stenosis caused by calcified plaques using synchrotron radiation computed tomography (CT) based on 3D printed coronary artery models. Methods Patient-specific 3D coronary models were created based on 3 sample coronary CT angiographic cases with calcified plaques in the left coronary arteries. In addition to the original significant coronary stenosis (>70%) shown on these CT images, stenoses of <50% and >90% were created in the segmented coronary models for simulation of different degrees of stenosis. The coronary lumen and calcification were printed with soft and rigid materials to simulate properties of coronary wall and calcified plaque, respectively. The models were scanned with synchrotron radiation CT with beam energies of 30, 40 and 50 keV and spatial resolution of 0.019×0.019×0.019 mm3 voxel size. Original high-resolution images were reconstructed with slice thicknesses of 0.095, 0.208, 0.302 and 0.491 mm to determine the effect of spatial resolution on plaque and coronary stenosis assessment based on 2D axial and 3D virtual intravascular endoscopy (VIE) images. Results Three coronary artery models were successfully printed with plaques placed in the coronary arteries to simulate different degrees of stenosis. 2D and 3D VIE images reconstructed with slice thicknesses of 0.095, 0.208 and 0.302 mm allowed for accurate assessment of coronary plaques and lumen stenosis with no significant differences (P>0.05). Synchrotron radiation CT images reconstructed with a slice thickness of 0.491 mm resulted in overestimation of coronary stenosis when compared to other images on 2D and 3D VIE views (<50% vs. 55-72%; 70-79% vs. 80-90%) with significant differences (P<0.05). Similarly, irregular plaque appearances were observed on 2D and 3D VIE images with a slice thickness of 0.491 mm when compared to others using thin slice thicknesses. The scanning protocol with beam energy of 30 keV provided optimal visualization of coronary lumen and plaque appearances. Conclusions This study shows the feasibility of using 3D printed coronary artery models to simulate calcifications and different degrees of coronary stenosis. High resolution synchrotron radiation CT imaging with the 30 keV beam energy enables accurate assessment of coronary stenosis in the presence of calcification, thus highlighting the importance of high spatial resolution in the diagnosis of calcified coronary plaques.
Collapse
Affiliation(s)
- Zhonghua Sun
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| | - Curtise K C Ng
- Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia
| | - Andrew Squelch
- Discipline of Exploration Geophysics, Western Australian School of Mines: Minerals, Energy and Chemical Engineering, Curtin University, Perth, Western Australia, Australia.,Computational Image Analysis Group, Curtin Institute for Computation, Curtin University, Perth, Western Australia, Australia
| |
Collapse
|
11
|
Hong SG, Kang EJ, Park JH, Choi WJ, Lee KN, Kwon HJ, Ha DH, Kim DW, Kim SH, Jo JH, Lee J. Effect of Hybrid Kernel and Iterative Reconstruction on Objective and Subjective Analysis of Lung Nodule Calcification in Low-Dose Chest CT. Korean J Radiol 2018; 19:888-896. [PMID: 30174478 PMCID: PMC6082754 DOI: 10.3348/kjr.2018.19.5.888] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Accepted: 03/02/2018] [Indexed: 12/30/2022] Open
Abstract
Objective To evaluate the differences in subjective calcification detection rates and objective calcium volumes in lung nodules according to different reconstruction methods using hybrid kernel (FC13-H) and iterative reconstruction (IR). Materials and Methods Overall, 35 patients with small (< 4 mm) calcified pulmonary nodules on chest CT were included. Raw data were reconstructed using filtered back projection (FBP) or IR algorithm (AIDR-3D; Canon Medical Systems Corporation), with three types of reconstruction kernel: conventional lung kernel (FC55), FC13-H and conventional soft tissue kernel (FC13). The calcium volumes of pulmonary nodules were quantified using the modified Agatston scoring method. Two radiologists independently interpreted the role of each nodule calcification on the six types of reconstructed images (FC55/FBP, FC55/AIDR-3D, FC13-H/FBP, FC13-H/AIDR-3D, FC13/FBP, and FC13/AIDR-3D). Results Seventy-eight calcified nodules detected on FC55/FBP images were regarded as reference standards. The calcium detection rates of FC55/AIDR-3D, FC13-H/FBP, FC13-H/AIDR-3D, FC13/FBP, and FC13/AIDR-3D protocols were 80.7%, 15.4%, 6.4%, 52.6%, and 28.2%, respectively, and FC13-H/AIDR-3D showed the smallest calcium detection rate. The calcium volume varied significantly with reconstruction protocols and FC13/AIDR-3D showed the smallest calcium volume (0.04 ± 0.22 mm3), followed by FC13-H/AIDR-3D. Conclusion Hybrid kernel and IR influence subjective detection and objective measurement of calcium in lung nodules, particularly when both techniques (FC13-H/AIDR-3D) are combined.
Collapse
Affiliation(s)
- Seul Gi Hong
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Eun-Ju Kang
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Jae Hyung Park
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Won Jin Choi
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Ki-Nam Lee
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Hee Jin Kwon
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Dong-Ho Ha
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Dong Won Kim
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Sang Hyeon Kim
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Jeong-Hyun Jo
- Department of Radiology, College of Medicine, Dong-A University, Busan 49201, Korea
| | - Jongmin Lee
- Department of Radiology, College of Medicine, Kyungpook National University, Daegu 41944, Korea
| |
Collapse
|
12
|
van der Werf NR, Willemink MJ, Willems TP, Greuter MJW, Leiner T. Influence of iterative reconstruction on coronary calcium scores at multiple heart rates: a multivendor phantom study on state-of-the-art CT systems. Int J Cardiovasc Imaging 2017; 34:947-957. [DOI: 10.1007/s10554-017-1292-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 12/19/2017] [Indexed: 10/18/2022]
|
13
|
Wolterink JM, Leiner T, Viergever MA, Isgum I. Generative Adversarial Networks for Noise Reduction in Low-Dose CT. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:2536-2545. [PMID: 28574346 DOI: 10.1109/tmi.2017.2708987] [Citation(s) in RCA: 420] [Impact Index Per Article: 60.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Noise is inherent to low-dose CT acquisition. We propose to train a convolutional neural network (CNN) jointly with an adversarial CNN to estimate routine-dose CT images from low-dose CT images and hence reduce noise. A generator CNN was trained to transform low-dose CT images into routine-dose CT images using voxelwise loss minimization. An adversarial discriminator CNN was simultaneously trained to distinguish the output of the generator from routine-dose CT images. The performance of this discriminator was used as an adversarial loss for the generator. Experiments were performed using CT images of an anthropomorphic phantom containing calcium inserts, as well as patient non-contrast-enhanced cardiac CT images. The phantom and patients were scanned at 20% and 100% routine clinical dose. Three training strategies were compared: the first used only voxelwise loss, the second combined voxelwise loss and adversarial loss, and the third used only adversarial loss. The results showed that training with only voxelwise loss resulted in the highest peak signal-to-noise ratio with respect to reference routine-dose images. However, CNNs trained with adversarial loss captured image statistics of routine-dose images better. Noise reduction improved quantification of low-density calcified inserts in phantom CT images and allowed coronary calcium scoring in low-dose patient CT images with high noise levels. Testing took less than 10 s per CT volume. CNN-based low-dose CT noise reduction in the image domain is feasible. Training with an adversarial network improves the CNNs ability to generate images with an appearance similar to that of reference routine-dose CT images.
Collapse
|
14
|
Halliburton SS, Tanabe Y, Partovi S, Rajiah P. The role of advanced reconstruction algorithms in cardiac CT. Cardiovasc Diagn Ther 2017; 7:527-538. [PMID: 29255694 DOI: 10.21037/cdt.2017.08.12] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Non-linear iterative reconstruction (IR) algorithms have been increasingly incorporated into clinical cardiac CT protocols at institutions around the world. Multiple IR algorithms are available commercially from various vendors. IR algorithms decrease image noise and are primarily used to enable lower radiation dose protocols. IR can also be used to improve image quality for imaging of obese patients, coronary atherosclerotic plaques, coronary stents, and myocardial perfusion. In this article, we will review the various applications of IR algorithms in cardiac imaging and evaluate how they have changed practice.
Collapse
Affiliation(s)
| | - Yuki Tanabe
- Cardiothoracic Imaging, Radiology Department, UT Southwestern Medical Center, Dallas, TX, USA
| | - Sasan Partovi
- University Hospitals Cleveland Medical Center, Cleveland, OH, USA
| | - Prabhakar Rajiah
- Cardiothoracic Imaging, Radiology Department, UT Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
15
|
Influence of dose reduction and iterative reconstruction on CT calcium scores: a multi-manufacturer dynamic phantom study. Int J Cardiovasc Imaging 2017; 33:899-914. [PMID: 28102510 PMCID: PMC5406488 DOI: 10.1007/s10554-017-1061-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Accepted: 01/02/2017] [Indexed: 11/13/2022]
Abstract
To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s corresponding to heart rates between 60 and 75 bpm. The inserts were scanned five times with routinely used CCS protocols at reference dose and 40 and 80% dose reduction on four high-end CT systems. Filtered back projection (FBP) and increasing levels of IR were applied. Noise levels were determined. CCS, quantified as Agatston and mass scores, were compared to physical mass and scores at FBP reference dose. For the reference dose in combination with FBP, noise level variation between CT systems was less than 18%. Decreasing dose almost always resulted in increased CCS, while at increased levels of IR, CCS decreased again. The influence of IR on CCS was smaller than the influence of dose reduction. At reference dose, physical mass was underestimated 3–30%. All CT systems showed similar CCS at 40% dose reduction in combinations with specific reconstructions. For some CT systems CCS was not affected at 80% dose reduction, in combination with IR. This multivendor study showed that radiation dose reductions of 40% did not influence CCS in a dynamic phantom using state-of-the-art CT systems in combination with specific reconstruction settings. Dose reduction resulted in increased noise and consequently increased CCS, whereas increased IR resulted in decreased CCS.
Collapse
|
16
|
Choi AD, Leifer ES, Yu J, Shanbhag SM, Bronson K, Arai AE, Chen MY. Prospective evaluation of the influence of iterative reconstruction on the reproducibility of coronary calcium quantification in reduced radiation dose 320 detector row CT. J Cardiovasc Comput Tomogr 2016; 10:359-63. [PMID: 27591767 PMCID: PMC7458582 DOI: 10.1016/j.jcct.2016.07.016] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Revised: 07/13/2016] [Accepted: 07/16/2016] [Indexed: 01/07/2023]
Abstract
BACKGROUND Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR; "reduced-dose/IR ") allows for similar image quality and reproducibility when compared to standard radiation dose acquisition with filtered back projection (FBP; "standard-dose/FBP") on 320-detector row computed tomography (320-CT). METHODS 200 consecutive patients (60 ± 9 years, 59% male) prospectively underwent two standard- and two reduced-dose acquisitions (800 total scans, 1600 reconstructions) using 320 slice CT and 120 kV tube voltage. Automated tube current modulation was used and for reduced-dose scans, prescribed tube current was lowered by 70%. Image noise and Agatston scores were determined and compared. RESULTS Regarding stratification by Agatston score categories (0, 1-10, 11-100, 101-400, >400), reduced-dose/IR versus standard-dose/FBP had excellent agreement at 89% (95% CI: 86-92%) with kappa 0.86 (95% CI: 0.81-0.90). Standard-dose/FBP rescan agreement was 93% (95% CI: 89-96%) with kappa = 0.91 (95% CI: 0.86-0.95) while reduced-dose/IR rescan agreement was similar at 91% (95% CI: 87-94%) with kappa 0.88 (95% CI: 0.83-0.93). Image noise was significantly higher but clinically acceptable for reduced-dose/IR (18 Hounsfield Unit [HU] mean) compared to standard-dose/FBP (16 HU; p < 0.0001). Median radiation exposure was 74% lower for reduced- (0.37 mSv) versus standard-dose (1.4 mSv) acquisitions. CONCLUSION Rescan agreement was excellent for reduced-dose image acquisition with iterative reconstruction and standard-dose acquisition with filtered back projection for the quantification of coronary calcium by CT. These methods make it possible to reduce radiation exposure by 74%. CLINICAL TRIAL REGISTRATION URL: https://clinicaltrials.gov/ct2/show/NCT01621594. UNIQUE IDENTIFIER NCT01621594.
Collapse
Affiliation(s)
- Andrew D Choi
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA; Division of Cardiology and Department of Radiology, The George Washington University School of Medicine, Washington, DC, USA
| | - Eric S Leifer
- Office of Biostatistics Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Jeannie Yu
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Sujata M Shanbhag
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Kathie Bronson
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Andrew E Arai
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA
| | - Marcus Y Chen
- Advanced Cardiovascular Imaging Laboratory, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA.
| |
Collapse
|
17
|
Abstract
Coronary computed tomography (CT) allows for the acquisition of thin slices of the heart and coronary arteries, which can be used to detect and quantify coronary artery calcium (CAC), a marker of atherosclerotic cardiovascular disease. Despite the proven clinical value in cardiac risk prognostication, there remain concerns regarding radiation exposure from CAC CT scans. There have been several recent technical advancements that allow for significant radiation dose reduction in CAC scoring. This paper reviews the clinical utility and recent literature in low radiation dose CAC scoring.
Collapse
|
18
|
Willemink MJ, den Harder AM, Foppen W, Schilham AM, Rienks R, Laufer EM, Nieman K, de Jong PA, Budde RP, Nathoe HM, Leiner T. Finding the optimal dose reduction and iterative reconstruction level for coronary calcium scoring. J Cardiovasc Comput Tomogr 2016; 10:69-75. [DOI: 10.1016/j.jcct.2015.08.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Revised: 08/01/2015] [Accepted: 08/18/2015] [Indexed: 01/07/2023]
|
19
|
Abstract
Coronary CT angiography (CTA) has emerged as a highly reliable and non-invasive modality for the exclusion of coronary artery disease. Recent technological advancements in coronary CTA imaging allow for robust qualitative and quantitative assessment of atherosclerotic plaques. Furthermore, CTA is a promising modality for functional evaluation of coronary lesions. Individual plaque features, the extent and severity of atherosclerotic plaque burden were proposed to improve cardiovascular risk stratification. It has been suggested that total atherosclerotic plaque burden is a stronger predictor of coronary events than total ischemia burden. The quest to noninvasively detect individual vulnerable plaques still remains. In the current review we sought to summarize state-of-the-art coronary artery plaque assessment by CTA.
Collapse
|