1
|
Spece H, Yarbrough RV, Kurtz SM. In Vivo Performance of Vitamin E Stabilized Polyethylene Implants for Total Hip Arthroplasty: A Review. J Arthroplasty 2022; 38:970-979. [PMID: 36481286 DOI: 10.1016/j.arth.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 10/28/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Vitamin E stabilization was introduced to improve the oxidative stability, wear resistance, and mechanical properties of highly crosslinked polyethylene (HXLPE). In this literature review, we asked: (1) How has vitamin E-stabilized HXLPE (VEPE) performed in vivo for total hip arthroplasty (THA) and how does it compare with conventional ultra-high molecular weight polyethylene (UHMWPE) and HXLPE without vitamin E; and (2) Is there an apparent difference in the clinical performance of VEPE created by blending versus diffusion? METHODS We performed a systematic search of the literature according to the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines using PubMed and Embase. Included studies reported the in vivo behavior of VEPE in THA. We reviewed 41 studies. RESULTS For all studies that compared polyethylene with and without VE stabilization, outcomes for VEPE were either equivalent or superior to the control group (for HXLPE without VE and conventional UHMWPE controls, respectively). Hip insert wear rates were generally less than 0.1 mm/year and in most cases were less than 0.05 mm/year. No VEPE components were revised for osteolysis or adverse outcomes specific to VE incorporation. CONCLUSION Across the literature, we found that VEPE was reported to be clinically effective for THA applications, with much of the research indicating positive clinical outcomes and lower or equivalent wear rates compared to conventional UHMWPE and HXLPE controls without VE. Instances of early component fracture were reported, but have multiple potential causes. There is a gap in the literature for comparison of blended and diffused components, so the in vivo impact of VE incorporation method remains to be seen. Overall, this study provides a comprehensive summary of VEPE clinical performance for THA and may serve as a resource for future investigations.
Collapse
Affiliation(s)
- Hannah Spece
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| | | | - Steven M Kurtz
- Implant Research Core, School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA; Gyroid, LLC, Haddonfield, NJ
| |
Collapse
|
2
|
Li Z, Xiang S, Wu C, Wang Y, Weng X. Vitamin E highly cross-linked polyethylene reduces mid-term wear in primary total hip replacement: a meta-analysis and systematic review of randomized clinical trials using radiostereometric analysis. EFORT Open Rev 2021; 6:759-770. [PMID: 34667647 PMCID: PMC8489480 DOI: 10.1302/2058-5241.6.200072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Vitamin E incorporation into highly cross-linked polyethylene (HXLPE) has been introduced to improve wear resistance, and vitamin E incorporated HXLPE (VEPE) has been used in total hip arthroplasty. The aim of this meta-analysis was to investigate the wear properties of VEPE in clinical practice by synthesizing the data provided in randomized clinical trials. The effects on implant stability, functional outcomes and revision rate of VEPE were also compared with those of HXPLE or ultra-high molecular weight polyethylene (UHMWPE). Literature searches were conducted on 1 January 2020 using MEDLINE, EMBASE, Cochrane and ClinicalTrials.gov databases. Randomized controlled trials (RCTs) comparing the aforementioned parameters between VEPE and standard HXPLE/UHMWPE liners were included. Methodological quality and the bias of the included studies were analysed. Meta-analyses were performed using the Review Manager software. Nine RCTs met the eligibility criteria and were included. At early and mid-term follow-up, the vertical penetration and the total penetration of the femoral head were both significantly reduced in the VEPE group. The steady state wear rate of the VEPE group was also remarkably lower. However, at two-year follow-up, significantly increased cup migration was observed in the VEPE group. Moreover, the mid-term clinical outcomes of the VEPE group were worse, while the total revision rates between the two groups were not significantly different. The limited number of included studies may compromise our conclusion regarding clinical outcomes of the VEPE bearing surface. More RCTs with longer follow-up periods are needed to further investigate the effects of VEPE in total hip arthroplasty.
Cite this article: EFORT Open Rev 2021;6:759-770. DOI: 10.1302/2058-5241.6.200072
Collapse
Affiliation(s)
- Zeng Li
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangdong, China.,Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China.,These authors contributed equally to the manuscript
| | - Shuai Xiang
- Department of Joint Surgery, the Affiliated Hospital of Qingdao University, Qingdao, Shandong, China.,These authors contributed equally to the manuscript
| | - Cuijiao Wu
- Department of Histology & Embryology, Qingdao University Medical School, Qingdao, Shandong, China
| | - Yingzhen Wang
- Department of Joint Surgery, the Affiliated Hospital of Qingdao University, Qingdao, Shandong, China
| | - Xisheng Weng
- Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, China
| |
Collapse
|
3
|
Hameister R, Kaur C, Dheen ST, Lohmann CH, Singh G. Reactive oxygen/nitrogen species (ROS/RNS) and oxidative stress in arthroplasty. J Biomed Mater Res B Appl Biomater 2020; 108:2073-2087. [PMID: 31898397 DOI: 10.1002/jbm.b.34546] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2019] [Revised: 11/19/2019] [Accepted: 12/08/2019] [Indexed: 12/16/2022]
Abstract
The interplay between implant design, biomaterial characteristics, and the local microenvironment adjacent to the implant is of utmost importance for implant performance and success of the joint replacement surgery. Reactive oxygen and nitrogen species (ROS/RNS) are among the various factors affecting the host as well as the implant components. Excessive formation of ROS and RNS can lead to oxidative stress, a condition that is known to damage cells and tissues and also to affect signaling pathways. It may further compromise implant longevity by accelerating implant degradation, primarily through activation of inflammatory cells. In addition, wear products of metallic, ceramic, polyethylene, or bone cement origin may also generate oxidative stress themselves. This review outlines the generation of free radicals and oxidative stress in arthroplasty and provides a conceptual framework on its implications for soft tissue remodeling and bone resorption (osteolysis) as well as implant longevity. Key findings derived from cell culture studies, animal models, and patients' samples are presented. Strategies to control oxidative stress by implant design and antioxidants are explored and areas of controversy and challenges are highlighted. Finally, directions for future research are identified. A better understanding of the host-implant interplay and the role of free radicals and oxidative stress will help to evaluate therapeutic approaches and will ultimately improve implant performance in arthroplasty.
Collapse
Affiliation(s)
- Rita Hameister
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Charanjit Kaur
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Shaikali Thameem Dheen
- Department of Anatomy, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Christoph H Lohmann
- Department of Orthopaedic Surgery, Otto-von-Guericke University, Magdeburg, Germany
| | - Gurpal Singh
- Centre for Orthopaedics Pte Ltd, Singapore, Singapore
| |
Collapse
|
4
|
The effect of vitamin E-enhanced cross-linked polyethylene on wear in shoulder arthroplasty-a wear simulator study. J Shoulder Elbow Surg 2019; 28:1771-1778. [PMID: 31029519 DOI: 10.1016/j.jse.2019.01.014] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 01/14/2019] [Accepted: 01/21/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Wear of the polyethylene glenoid component and subsequent particle-induced osteolysis remains one of the most important modes of failure of total shoulder arthroplasty. Vitamin E is added to polyethylene to act as an antioxidant to stabilize free radicals that exist as a byproduct of irradiation used to induce cross-linking. This study was performed to assess the in vitro performance of vitamin E-enhanced polyethylene compared with conventional polyethylene in a shoulder simulator model. METHODS Vitamin E-enhanced, highly cross-linked glenoid components were compared with conventional ultrahigh-molecular-weight polyethylene glenoids, both articulating with a ceramic humeral head component using a shoulder joint simulator over 500,000 cycles. Unaged and artificially aged comparisons were performed. Volumetric wear was assessed by gravimetric measurement, and wear particle analysis was also subsequently performed. RESULTS Vitamin E-enhanced polyethylene glenoid components were found to have significantly reduced wear rates compared with conventional polyethylene in both unaged (36% reduction) and artificially aged (49% reduction) comparisons. There were no differences detected in wear particle analysis between the 2 groups. CONCLUSION Vitamin E-enhanced polyethylene demonstrates improved wear compared with conventional polyethylene in both unaged and artificially aged comparisons and may have clinically relevant benefits.
Collapse
|
5
|
Takemura S, Minoda Y, Sugama R, Ohta Y, Nakamura S, Ueyama H, Nakamura H. Comparison of a vitamin E-infused highly crosslinked polyethylene insert and a conventional polyethylene insert for primary total knee arthroplasty at two years postoperatively. Bone Joint J 2019; 101-B:559-564. [PMID: 31039001 DOI: 10.1302/0301-620x.101b5.bjj-2018-1355.r1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
AIMS The use of vitamin E-infused highly crosslinked polyethylene (HXLPE) in total knee prostheses is controversial. In this paper we have compared the clinical and radiological results between conventional polyethylene and vitamin E-infused HXLPE inserts in total knee arthroplasty (TKA). PATIENTS AND METHODS The study included 200 knees (175 patients) that underwent TKA using the same total knee prostheses. In all, 100 knees (77 patients) had a vitamin E-infused HXLPE insert (study group) and 100 knees (98 patients) had a conventional polyethylene insert (control group). There were no significant differences in age, sex, diagnosis, preoperative knee range of movement (ROM), and preoperative Knee Society Score (KSS) between the two groups. Clinical and radiological results were evaluated at two years postoperatively. RESULTS Differences in postoperative ROM and KSS were not statistically significant between the study and control groups. No knee exhibited osteolysis, aseptic loosening, or polyethylene failure. Additionally, there was no significant difference in the incidence of a radiolucent line between the two groups. One patient from the study group required irrigation and debridement, due to deep infection, at six months postoperatively. CONCLUSION Clinical results were comparable between vitamin E-infused HXLPE inserts and conventional polyethylene inserts at two years after TKA, without any significant clinical failure. Cite this article: Bone Joint J 2019;101-B:559-564.
Collapse
Affiliation(s)
- S Takemura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Minoda
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - R Sugama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Ohta
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - S Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Ueyama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
6
|
Galliera E, Ragone V, Marazzi MG, Selmin F, Banci L, Corsi Romanelli MM. Vitamin E-stabilized UHMWPE: Biological response on human osteoblasts to wear debris. Clin Chim Acta 2018; 486:18-25. [DOI: 10.1016/j.cca.2018.07.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Accepted: 07/09/2018] [Indexed: 12/31/2022]
|
7
|
Ludwig KB, Chandrasekar V, Saylor DM, Van Citters DW, Reinitz SD, Forrey C, McDermott MK, Wickramasekara S, Janes DW. Characterizing the free volume of ultrahigh molecular weight polyethylene to predict diffusion coefficients in orthopedic liners. J Biomed Mater Res B Appl Biomater 2017; 106:2393-2402. [DOI: 10.1002/jbm.b.34045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Revised: 08/21/2017] [Accepted: 10/31/2017] [Indexed: 11/10/2022]
Affiliation(s)
- Kyle B. Ludwig
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - Vaishnavi Chandrasekar
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - David M. Saylor
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | | | - Steven D. Reinitz
- Thayer School of Engineering; Dartmouth College; Hanover New Hampshire 03755
| | - Christopher Forrey
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - Martin K. McDermott
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | - Samanthi Wickramasekara
- Center for Devices and Radiological Health, U.S. Food and Drug Administration; Silver Spring Maryland 20993
| | | |
Collapse
|
8
|
Gigante A, Bottegoni C, Ragone V, Banci L. Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review. J Funct Biomater 2015; 6:889-900. [PMID: 26371052 PMCID: PMC4598683 DOI: 10.3390/jfb6030889] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 07/24/2015] [Accepted: 08/08/2015] [Indexed: 12/25/2022] Open
Abstract
Since polyethylene is one of the most frequently used biomaterials, such as in bearing components in joint arthroplasty, strong efforts have been made to improve the design and material properties over the last decades. Antioxidants, such as vitamin-E, seem to be a promising alternative to further increase durability and reduce polyethylene wear and degradation in the long-term. Nevertheless, even if several promising in vitro results are available, there is yet no clinical evidence that vitamin-E polyethylenes show these advantages in vivo. The aim of this paper was to provide a comprehensive overview on the current knowledge regarding the biological and mechanical proprieties of this biomaterial, underlying the in vitro and in vivo evidence for effectiveness of vitamin-E-doped polyethylene in joint arthroplasty.
Collapse
Affiliation(s)
- Antonio Gigante
- Clinical Orthopaedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, via Tronto 10/A, 60126 Ancona, Italy.
| | - Carlo Bottegoni
- Clinical Orthopaedics, Department of Clinical and Molecular Science, School of Medicine, Università Politecnica delle Marche, via Tronto 10/A, 60126 Ancona, Italy.
| | - Vincenza Ragone
- Research and Development Department, Permedica S.p.A., via Como 38, 23807 Merate (LC), Italy.
| | - Lorenzo Banci
- Research and Development Department, Permedica S.p.A., via Como 38, 23807 Merate (LC), Italy.
| |
Collapse
|
9
|
van der Veen HC, van den Akker-Scheek I, Bulstra SK, van Raay JJ. Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial. BMC Musculoskelet Disord 2012; 13:178. [PMID: 22994935 PMCID: PMC3517763 DOI: 10.1186/1471-2474-13-178] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2012] [Accepted: 09/19/2012] [Indexed: 11/11/2022] Open
Abstract
Background Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to compare vitamin E-stabilized highly cross-linked polyethylene with conventional cross-linked polyethylene in “reversed hybrid” total hip arthroplasties (cemented all-polyethylene cups combined with uncemented femoral stems). We hypothesize that the adjunction of vitamin E leads to a decrease in polyethylene wear in the long-term. We also expect changes in bone mineral density, less osteolysis, equal functional scores and increased implant survival in polyethylene cemented cups incorporated with vitamin E in the long-term. Design A double-blinded randomized controlled trial will be conducted. Patients to be included are aged under 70, suffer from non-inflammatory degenerative joint disease of the hip and are scheduled for a primary total hip arthroplasty. The study group will receive a reversed hybrid total hip arthroplasty with a vitamin E-stabilized highly cross-linked polyethylene cemented cup. The control group will receive a reversed hybrid total hip arthroplasty with a conventional cross-linked polyethylene cemented cup. Radiological follow-up will be assessed at 6 weeks and at 1, 3, 5, 7 and 10 years postoperatively, to determine polyethylene wear and osteolysis. Patient-reported functional status (HOOS), physician-reported functional status (Harris Hip Score) and patients’ physical activity behavior (SQUASH) will also be assessed at these intervals. Acetabular bone mineral density will be assessed by dual energy X-ray absorptiometry (DEXA) at 6 weeks and at 1 year and 2 years postoperatively. Implant survival will be determined at 10 years postoperatively. Discussion In vitro results of vitamin E-stabilized polyethylene are promising, showing increased wear resistance. However, controlled clinical follow-up data are not available at this moment. This randomized controlled trial has been designed to determine wear, bone mineral density, functional outcome and survival in reversed hybrid total hip arthroplasty comparing cemented vitamin E-stabilized highly cross-linked polyethylene cups with cemented conventional cross-linked polyethylene cups. Trial registration Dutch Trial Registry NTR3049
Collapse
Affiliation(s)
- Hugo C van der Veen
- Department of Orthopaedic Surgery, Martini Hospital, P,O, Box 30033, 9700, RM, Groningen, The Netherlands.
| | | | | | | |
Collapse
|
10
|
Jarrett BT, Cofske J, Rosenberg AE, Oral E, Muratoglu O, Malchau H. In vivo biological response to vitamin E and vitamin-E-doped polyethylene. J Bone Joint Surg Am 2010; 92:2672-81. [PMID: 21084577 DOI: 10.2106/jbjs.i.00068] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Cross-linking has decreased the wear of ultra-high molecular weight polyethylene, a cause of osteolysis leading to total joint replacement failure. Compared with melting or annealing, doping cross-linked ultra-high molecular weight polyethylene with vitamin E stabilizes free radicals from irradiation while maintaining mechanical properties and wear resistance. This study was done to determine the local tissue effects of free vitamin E and vitamin E eluted from ultra-high molecular weight polyethylene implants in the joint space. METHODS Three studies were performed. First, pure vitamin E and solubilized vitamin E were injected into rabbit knees to simulate vitamin-E elution from radiation cross-linked ultra-high molecular weight polyethylene; second, vitamin-E-doped, irradiated ultra-high molecular weight polyethylene plugs were implanted into dorsal subcutaneous pouches of rabbits to determine the local effects of vitamin-E elution from radiation cross-linked ultra-high molecular weight polyethylene; and, third, two groups of vitamin-E-doped, irradiated acetabular liners (high surface and uniform vitamin-E concentration profiles) were compared with undoped, control ultra-high molecular weight polyethylene liners in a canine model of total hip replacement to determine the effect of possible vitamin-E elution on bone ingrowth and the local tissue response to it in a load-bearing environment. RESULTS Injection of solubilized vitamin E resulted in histologically normal surrounding soft tissue at both two and twelve-week follow-up intervals, while injection of pure vitamin E resulted in acute and chronic inflammation at the time of the two-week follow-up. Both control and vitamin-E-doped subcutaneous plugs showed inflammation associated with surgery at two weeks of follow-up, but showed stable fibrous encapsulation without inflammation at twelve weeks of follow-up. In the canine total hip replacement model, there was no qualitative difference in local tissue appearance and no significant difference in the percent bone ingrowth and the percent bone density between the control and vitamin-E groups. CONCLUSIONS These investigations showed that vitamin-E-doped ultra-high molecular weight polyethylene plugs and total hip replacement components are well tolerated in both a small and a large-animal model with no observed adverse effects on the surrounding tissues at twelve weeks of follow-up.
Collapse
Affiliation(s)
- Bryan T Jarrett
- Harris Orthopaedic Biomechanics and Biomaterials Laboratory, Massachusetts General Hospital, 1125 Gray/Jackson, 55 Fruit Street, Boston, MA 02115, USA.
| | | | | | | | | | | |
Collapse
|
11
|
Girdhar G, Bluestein D. Biological effects of dynamic shear stress in cardiovascular pathologies and devices. Expert Rev Med Devices 2008; 5:167-81. [PMID: 18331179 PMCID: PMC2865252 DOI: 10.1586/17434440.5.2.167] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Altered and highly dynamic shear stress conditions have been implicated in endothelial dysfunction leading to cardiovascular disease, and in thromboembolic complications in prosthetic cardiovascular devices. In addition to vascular damage, the pathological flow patterns characterizing cardiovascular pathologies and blood flow in prosthetic devices induce shear activation and damage to blood constituents. Investigation of the specific and accentuated effects of such flow-induced perturbations on individual cell-types in vitro is critical for the optimization of device design, whereby specific design modifications can be made to minimize such perturbations. Such effects are also critical in understanding the development of cardiovascular disease. This review addresses limitations to replicate such dynamic flow conditions in vitro and also introduces the idea of modified in vitro devices, one of which is developed in the authors' laboratory, with dynamic capabilities to investigate the aforementioned effects in greater detail.
Collapse
Affiliation(s)
- Gaurav Girdhar
- Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794-8181, USA.
| | | |
Collapse
|