Matsuoka T, Takahashi Y, Ishida T, Tateiwa T, Shishido T, Yamamoto K. In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty. Arch Orthop Trauma Surg 2023; 143:7195-7203. [PMID: 37438580 DOI: 10.1007/s00402-023-04972-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Accepted: 06/26/2023] [Indexed: 07/14/2023]
Abstract
INTRODUCTION An acetabular liner thickness of around 6 mm remains the "gold standard" in total hip arthroplasty. Some surgeons have been recommending the use of the thickest possible liner because contact stress and strain in articulating surfaces decrease with increasing the wall thickness. The purpose of this study was to determine whether in vivo creep and wear performance could be enhanced using a thicker liner over the standard thickness in vitamin-E-diffused highly crosslinked polyethylene (HXLPE). MATERIALS AND METHODS One hundred and twenty-two hips were allocated to age-matched, sex-matched, and body mass index-matched two subgroups implanted either with a 6.8- or 8.9-mm-thick vitamin-E-diffused HXLPE liner against 28-mm cobalt-chrome femoral head, and followed-up for 7 years. Linear and volumetric penetration of femoral head into the liners attributed to creep and wear were analyzed for each group. RESULTS Compressive creep strain generated at the initial 6 months was significantly larger in the 6.8-mm group (2.6%) than in the 8.9-mm group (2.2%). The linear steady-state wear observed after 2 years was 0.0019 and 0.0015 mm/year, whereas the volumetric steady-state wear was 0.54 and 0.45 mm3/years in the 6.8- and 8.9-mm-thick groups, respectively. Although less strain in the thicker group resulted in a slightly less wear, it did not reach significant differences in the steady-state wear rates between the groups. CONCLUSION No clinical significance for using a thicker liner over the standard thickness (6.8 mm → 8.9 mm) was confirmed in the vitamin-E-diffused HXLPE according to the 7-year follow-up. The wear rates for both thicknesses were very low enough to prevent osteolysis, and no mechanical failure was observed at any follow-up interval. Nevertheless, since the significantly higher strain was seen in the thinner liner, further follow-up is needed to compare the longer term wear and the incidence of osteolysis and component fracture.
Collapse
Affiliation(s)
- Tsunehiro Matsuoka
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Yasuhito Takahashi
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
- Department of Bone and Joint Biomaterial Research, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
| | - Tsunehito Ishida
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Toshiyuki Tateiwa
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Takaaki Shishido
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| | - Kengo Yamamoto
- Department of Orthopedic Surgery, Tokyo Medical University, 6-7-1, Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan
| |
Collapse
|
2
|
Cheung A, Chan PK, Fu H, Cheung MH, Chan VWK, Luk MH, Chiu KY. Metal-on-crosslinked polyethylene in total hip arthroplasty - an excellent combination at fifteen to twenty years of follow-up. Int Orthop 2023; 47:2547-2552. [PMID: 37247019 DOI: 10.1007/s00264-023-05844-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 05/15/2023] [Indexed: 05/30/2023]
Abstract
PURPOSE Cross-linked polyethylene (PE) has been used with great clinical success in total hip arthroplasty (THA) since its debut in the late 1990's. However, reports regarding this bearing couple near the end of its second decade of service are still scant. The aim of this study was to first determine the long term clinical and radiological results and second Investigate what factors affect wear rates using a metal-on-crosslinked PE bearing articulation. METHODS 55 THAs using a single brand of cross-linked liner, cementless cup and 28 mm hip ball were performed in 44 patients. Age, sex, Charlson Comorbidity Index (CCI) and need for revision surgery were recorded. Linear and volumetric wear was determined using the Martell method. RESULTS Mean age at operation was 51.2 (29-73 ± 12.1) years. Mean duration of follow-up was 16.9 years (range 15.0-20.1 ± 1.1 years). Osteolysis was not present in the latest follow-up radiographs. Median linear and volumetric wear rate was 0.038 mm/year (95% CI 0.032-0.047) and 7.115mm3/year (95% CI 6.92-17.25) respectively. Acetabular component position was not found to be related to both linear and volumetric wear. No significant difference was found in the linear and volumetric wear rates of thinner and thicker liners (8 mm or below and > 8 mm) (p = 0.849 and p = 0.64 respectively). CONCLUSION Metal-on-crosslinked PE is associated with low linear and volumetric wear rates which has virtually obviated osteolysis and has translated to excellent survivorship even at long term follow up. In-vivo oxidation does not appear to be of clinical concern at this point.
Collapse
Affiliation(s)
- Amy Cheung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China.
| | - Ping Keung Chan
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Henry Fu
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Man Hong Cheung
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Vincent Wai Kwan Chan
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Michelle Hilda Luk
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| | - Kwong-Yuen Chiu
- Department of Orthopaedics and Traumatology, Queen Mary Hospital, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong SAR, China
| |
Collapse
|
3
|
Abstract
More than two decades after their clinical introduction, crosslinked polyethylenes (XLPE) have been widely adopted. Though concerns were initially raised regarding oxidation and brittleness, on a large scale, the first generation of XLPE continues to be highly effective 15 years after the surgery, even in a young and active population. Remelted XLPE might display lower wear rates than annealed XLPE. Second generation XLPEs, not only including sequentially irradiated and annealed but also associated with antioxidants, demonstrate encouraging short- to mid-term results. Registry data support clinical trial reports. Even in less favorable settings (lipped liners, dual mobility cups, revision surgery, hip resurfacing) results are promising. However, failures (fractures) have already been described. Therefore, a high level of surveillance remains crucial.
Collapse
Affiliation(s)
- Jean Langlois
-
Centre Orthopédique Santy 24, avenue Paul Santy 69008 Lyon France
-
Hôpital Privé Jean-Mermoz 55, avenue Jean-Mermoz 69008 Lyon France
| | - Moussa Hamadouche
-
Département de Chirurgie Orthopédique, Université Paris-Descartes, Assistance Publique-Hôpitaux de Paris, Hôpital Cochin 27, rue du Faubourg Saint-Jacques 75014 Paris France
| |
Collapse
|
4
|
Sköldenberg OG, Rysinska AD, Chammout G, Salemyr M, Mukka SS, Bodén H, Eisler T. A randomized double-blind noninferiority trial, evaluating migration of a cemented vitamin E-stabilized highly crosslinked component compared with a standard polyethylene component in reverse hybrid total hip arthroplasty. Bone Joint J 2019; 101-B:1192-1198. [PMID: 31564144 DOI: 10.1302/0301-620x.101b10.bjj-2019-0456.r2] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
AIMS Radiostereometric analysis (RSA) studies of vitamin E-doped, highly crosslinked polyethylene (VEPE) liners show low head penetration rates in cementless acetabular components. There is, however, currently no data on cemented VEPE acetabular components in total hip arthroplasty (THA). The aim of this study was to evaluate the safety of a new cemented VEPE component, compared with a conventional polyethylene (PE) component regarding migration, head penetration, and clinical results. PATIENTS AND METHODS We enrolled 42 patients (21 male, 21 female) with osteoarthritis and a mean age of 67 years (sd 5), in a double-blinded, noninferiority, randomized controlled trial. The subjects were randomized in a 1:1 ratio to receive a reverse hybrid THA with a cemented component of either argon-gas gamma-sterilized PE component (controls) or VEPE, with identical geometry. The primary endpoint was proximal implant migration of the component at two years postoperatively measured with RSA. Secondary endpoints included total migration of the component, penetration of the femoral head into the component, and patient-reported outcome measurements. RESULTS In total, 19 control implants and 18 implants in the VEPE group were analyzed for the primary endpoint. We found a continuous proximal migration of the component in the VEPE group that was significantly higher with a difference at two years of a mean 0.21 mm (95% confidence interval (CI) 0.05 to 0.37; p = 0.013). The total migration was also significantly higher in the VEPE group, but femoral head penetration was lower. We found no difference in clinical outcomes between the groups. CONCLUSION At two years, this cemented VEPE component, although having a low head penetration and excellent clinical results, failed to meet noninferiority compared with the conventional implant by a proximal migration above the proposed safety threshold of RSA. The early proximal migration pattern of the VEPE component is a reason for continued monitoring, although a specific threshold for proximal migration and risk for later failure cannot be defined and needs further study. Cite this article: Bone Joint J 2019;101-B:1192-1198.
Collapse
Affiliation(s)
- Olof G Sköldenberg
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Agata D Rysinska
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Ghaz Chammout
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Mats Salemyr
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Sebastian S Mukka
- Department of Surgical and Perioperative Sciences, Umeå University, Umeå, Sweden
| | - Henrik Bodén
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| | - Thomas Eisler
- Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, Division of Orthopaedics, Stockholm, Sweden
| |
Collapse
|
5
|
Takemura S, Minoda Y, Sugama R, Ohta Y, Nakamura S, Ueyama H, Nakamura H. Comparison of a vitamin E-infused highly crosslinked polyethylene insert and a conventional polyethylene insert for primary total knee arthroplasty at two years postoperatively. Bone Joint J 2019; 101-B:559-564. [PMID: 31039001 DOI: 10.1302/0301-620x.101b5.bjj-2018-1355.r1] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
AIMS The use of vitamin E-infused highly crosslinked polyethylene (HXLPE) in total knee prostheses is controversial. In this paper we have compared the clinical and radiological results between conventional polyethylene and vitamin E-infused HXLPE inserts in total knee arthroplasty (TKA). PATIENTS AND METHODS The study included 200 knees (175 patients) that underwent TKA using the same total knee prostheses. In all, 100 knees (77 patients) had a vitamin E-infused HXLPE insert (study group) and 100 knees (98 patients) had a conventional polyethylene insert (control group). There were no significant differences in age, sex, diagnosis, preoperative knee range of movement (ROM), and preoperative Knee Society Score (KSS) between the two groups. Clinical and radiological results were evaluated at two years postoperatively. RESULTS Differences in postoperative ROM and KSS were not statistically significant between the study and control groups. No knee exhibited osteolysis, aseptic loosening, or polyethylene failure. Additionally, there was no significant difference in the incidence of a radiolucent line between the two groups. One patient from the study group required irrigation and debridement, due to deep infection, at six months postoperatively. CONCLUSION Clinical results were comparable between vitamin E-infused HXLPE inserts and conventional polyethylene inserts at two years after TKA, without any significant clinical failure. Cite this article: Bone Joint J 2019;101-B:559-564.
Collapse
Affiliation(s)
- S Takemura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Minoda
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - R Sugama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - Y Ohta
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - S Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Ueyama
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| | - H Nakamura
- Department of Orthopaedic Surgery, Osaka City University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
6
|
Teeter MG, Lanting BA, Naudie DD, McCalden RW, Howard JL, MacDonald SJ. Highly crosslinked polyethylene wear rates and acetabular component orientation: a minimum ten-year follow-up. Bone Joint J 2018; 100-B:891-897. [PMID: 29954202 DOI: 10.1302/0301-620x.100b7.bjj-2017-1457.r3] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Aims The aim of this study was to determine whether there is a difference in the rate of wear between acetabular components positioned within and outside the 'safe zones' of anteversion and inclination angle. Patients and Methods We reviewed 100 hips in 94 patients who had undergone primary total hip arthroplasty (THA) at least ten years previously. Patients all had the same type of acetabular component with a bearing couple which consisted of a 28 mm cobalt-chromium head on a highly crosslinked polyethylene (HXLPE) liner. A supine radiostereometric analysis (RSA) examination was carried out which acquired anteroposterior (AP) and lateral paired images. Acetabular component anteversion and inclination angles were measured as well as total femoral head penetration, which was divided by the length of implantation to determine the rate of polyethylene wear. Results The mean anteversion angle was 19.4° (-15.2° to 48°, sd 11.4°), the mean inclination angle 43.4° (27.3° to 60.5°, sd 6.6°), and the mean wear rate 0.055 mm/year (sd 0.060). Exactly half of the hips were positioned inside the 'safe zone'. There was no difference (median difference, 0.012 mm/year; p = 0.091) in the rate of wear between acetabular components located within or outside the 'safe zone'. When compared to acetabular components located inside the 'safe zone', the wear rate was no different for acetabular components that only achieved the target anteversion angle (median difference, 0.012 mm/year; p = 0.138), target inclination angle (median difference, 0.013 mm/year; p = 0.354), or neither target (median difference, 0.012 mm/year; p = 0.322). Conclusion Placing the acetabular component within or outside the 'safe zone' did not alter the wear rate of HXLPE at long-term follow-up to a level that risked osteolysis. HXLPE appears to be a forgiving bearing material in terms of articular surface wear, but care must still be taken to position the acetabular component correctly so that the implant is stable. Cite this article: Bone Joint J 2018;100-B:891-7.
Collapse
Affiliation(s)
- M G Teeter
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - B A Lanting
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - D D Naudie
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - R W McCalden
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - J L Howard
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| | - S J MacDonald
- Department of Surgery, Schulich School of Medicine and Dentistry, Western University and London Health Sciences Centre, London, Ontario, Canada
| |
Collapse
|
7
|
Teeter MG, MacLean CJ, Somerville LE, Howard JL, McCalden RW, Lanting BA, Vasarhelyi EM. Wear performance of cobalt chromium, ceramic, and oxidized zirconium on highly crosslinked polyethylene at mid-term follow-up. J Orthop 2018; 15:620-623. [PMID: 29881207 DOI: 10.1016/j.jor.2018.05.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2018] [Accepted: 05/06/2018] [Indexed: 10/17/2022] Open
Abstract
Patients with THA using a ceramic head and using an OxZr head were each matched to patients with a CoCr head. Mean implantation time was 5 years. There was no difference in steady state wear rate between the ceramic (0.066 ± 0.050 mm/year) and CoCr match groups (0.052 ± 0.041 mm/year), or between the OxZr (0.022 ± 0.029 mm/year) and CoCr match groups (0.048 ± 0.071 mm/year). Follow-up into the second decade will be necessary before any changes in THA wear rate from using ceramic or OxZr bearings may be appreciated clinically with available imaging techniques.
Collapse
Affiliation(s)
- Matthew G Teeter
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada.,Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada.,Imaging Research Laboratories, Robarts Research Institute, London, Ontario, Canada
| | - Colin J MacLean
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada
| | - Lyndsay E Somerville
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada
| | - James L Howard
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada
| | - Richard W McCalden
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada
| | - Brent A Lanting
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada
| | - Edward M Vasarhelyi
- Department of Surgery, Schulich School of Medicine & Dentistry, Western University and London Health Sciences Centre, London, Ontari, Canada
| |
Collapse
|
8
|
Callary SA, Field JR, Campbell DG. The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used. Bone Joint J 2017; 98-B:1604-1610. [PMID: 27909121 DOI: 10.1302/0301-620x.98b12.37682] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Accepted: 08/12/2016] [Indexed: 01/12/2023]
Abstract
AIMS The increased in vivo resistance to wear of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA) has led to an increased use of larger articulations which have been shown to reduce the incidence of early dislocation. To date, there are few reports of the wear of larger articulations using second generation HXLPE liners. Our prospective cohort study measured the bedding-in and early wear of large (36 mm and 40 mm diameter) articulations involving a second generation X3 HXLPE liner and compared our findings with previous clinical and in vitro studies of the same material. PATIENTS AND METHODS The proximal penetration of the femoral head five years post-operatively was measured for 15 patients using radiostereometric analysis (RSA). RESULTS The median proximal bedding-in within the first post-operative year was 0.022 mm (interquartile range (IQR) -0.050 to 0.091). The median proximal rate of wear between one and five years was -0.004 mm/year (IQR -0.021 to 0.022). The rates of proximal, medial, 2D or 3D wear between one and five years post-operatively of the X3 HXLPE liner did not increase with larger articulations compared with our previous study of 32 mm articulations. CONCLUSION Although reassuring, the use of larger articulations requires continued monitoring to determine whether the low wear observed in the short-term continues to the mid- to long-term. Cite this article: Bone Joint J 2016;98-B:1604-10.
Collapse
Affiliation(s)
- S A Callary
- Royal Adelaide Hospital, Orthopaedics and Trauma, Level 4, Bice Building, North Terrace, Adelaide, South Australia, 5000, Australia
| | - J R Field
- University of Adelaide, Adelaide 5000, South Australia, Australia
| | - D G Campbell
- Wakefield Orthopaedic Clinic, Wakefield Street, Adelaide 5000, South Australia, Australia
| |
Collapse
|
9
|
Malatray M, Roux JP, Gunst S, Pibarot V, Wegrzyn J. Highly crosslinked polyethylene: a safe alternative to conventional polyethylene for dual mobility cup mobile component. A biomechanical validation. Int Orthop 2016; 41:507-512. [PMID: 27837329 DOI: 10.1007/s00264-016-3334-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2016] [Accepted: 10/31/2016] [Indexed: 11/30/2022]
Abstract
PURPOSE Dual mobility cup (DMC) consists of a cobalt-chromium (CoCr) alloy cup articulated with a polyethylene (PE) mobile component capturing the femoral head in force using a snap-fit technique. This biomechanical study was the first to evaluate and compare the generation of cracks in the retentive area of DMC mobile components made of highly crosslinked PE (XLPE) or conventional ultra-high molecular weight PE (UHMWPE). METHODS Eighty mobile components designed for a 52-mm diameter Symbol® DMC (Dedienne Santé, Mauguio, France) and a 28-mm diameter femoral head were analyzed. Four groups of 20 mobile components were constituted according to the PE material: raw UHMWPE, sterilized UHMWPE, annealed XLPE and remelted XLPE. Ten mobile components in each group were impacted with a 28-mm diameter CoCr femoral head using a snap-fit technique. The occurrence, location and area of the cracks in the retentive area were investigated using micro-CT (Skyscan 1176®, Bruker, Aarsellar, Belgium) with a 35 μm nominal isotropic voxel size by two observers blinded to the PE material and impaction or not of the mobile components. RESULTS Compared to conventional UHMWPE, the femoral head snap-fit did not generate more or wider cracks in the retentive area of annealed or remelted XLPE mobile components. CONCLUSION This biomechanical study suggests that XLPE in DMC could be a safe alternative to conventional UHMWPE regarding the generation of cracks in the retentive area related to the femoral head snap-fit.
Collapse
Affiliation(s)
- Matthieu Malatray
- Department of Orthopedic Surgery - Pavillon T, Hôpital Edouard Herriot, Hospices Civils de Lyon, 5, place d'Arsonval, 69437, Lyon, France
- INSERM UMR 1033, Université de Lyon, Lyon, France
| | | | - Stanislas Gunst
- Department of Orthopedic Surgery - Pavillon T, Hôpital Edouard Herriot, Hospices Civils de Lyon, 5, place d'Arsonval, 69437, Lyon, France
| | - Vincent Pibarot
- Department of Orthopedic Surgery - Pavillon T, Hôpital Edouard Herriot, Hospices Civils de Lyon, 5, place d'Arsonval, 69437, Lyon, France
| | - Julien Wegrzyn
- Department of Orthopedic Surgery - Pavillon T, Hôpital Edouard Herriot, Hospices Civils de Lyon, 5, place d'Arsonval, 69437, Lyon, France.
- INSERM UMR 1033, Université de Lyon, Lyon, France.
| |
Collapse
|