van Wyk L, Austin T, Barzilay B, Bravo MC, Breindahl M, Czernik C, Dempsey E, de Boode WP, de Vries W, Eriksen BH, Fauchére JC, Kooi EMW, Levy PT, McNamara PJ, Mitra S, Nestaas E, Rabe H, Rabi Y, Rogerson SR, Savoia M, Schena F, Sehgal A, Schwarz CE, Thome U, van Laere D, Zaharie GC, Gupta S. A recommendation for the use of electrical biosensing technology in neonatology. Pediatr Res 2025; 97:510-523. [PMID: 38977797 PMCID: PMC12015118 DOI: 10.1038/s41390-024-03369-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 05/17/2024] [Accepted: 06/07/2024] [Indexed: 07/10/2024]
Abstract
Non-invasive cardiac output monitoring, via electrical biosensing technology (EBT), provides continuous, multi-parameter hemodynamic variable monitoring which may allow for timely identification of hemodynamic instability in some neonates, providing an opportunity for early intervention that may improve neonatal outcomes. EBT encompasses thoracic (TEBT) and whole body (WBEBT) methods. Despite the lack of relative accuracy of these technologies, as compared to transthoracic echocardiography, the use of these technologies in neonatology, both in the research and clinical arena, have increased dramatically over the last 30 years. The European Society of Pediatric Research Special Interest Group in Non-Invasive Cardiac Output Monitoring, a group of experienced neonatologists in the field of EBT, deemed it appropriate to provide recommendations for the use of TEBT and WBEBT in the field of neonatology. Although TEBT is not an accurate determinant of cardiac output or stroke volume, it may be useful for monitoring longitudinal changes of hemodynamic parameters. Few recommendations can be made for the use of TEBT in common neonatal clinical conditions. It is recommended not to use WBEBT to monitor cardiac output. The differences in technologies, study methodologies and data reporting should be addressed in ongoing research prior to introducing EBT into routine practice. IMPACT STATEMENT: TEBT is not recommended as an accurate determinant of cardiac output (CO) (or stroke volume (SV)). TEBT may be useful for monitoring longitudinal changes from baseline of hemodynamic parameters on an individual patient basis. TEBT-derived thoracic fluid content (TFC) longitudinal changes from baseline may be useful in monitoring progress in respiratory disorders and circulatory conditions affecting intrathoracic fluid volume. Currently there is insufficient evidence to make any recommendations regarding the use of WBEBT for CO monitoring in neonates. Further research is required in all areas prior to the implementation of these monitors into routine clinical practice.
Collapse
Affiliation(s)
- Lizelle van Wyk
- Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Cape Town, South Africa.
| | - Topun Austin
- Neonatal Intensive Care Unit, Rosie Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge Biomedical Campus, Cambridge, UK
| | - Bernard Barzilay
- Neonatal Intensive Care Unit, Assaf Harofeh Medical Center, Tzrifin, Israel
| | - Maria Carmen Bravo
- Department of Neonatology, La Paz University Hospital and IdiPaz, Madrid, Spain
| | - Morten Breindahl
- Department of Neonatology, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark
| | - Christoph Czernik
- Department of Neonatology, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Eugene Dempsey
- Department of Paediatrics and Child Health, University College Cork, Cork, Ireland
| | - Willem-Pieter de Boode
- Department of Neonatology, Radboud University Medical Center, Radboud Institute for Health Sciences, Amalia Children's Hospital, Nijmegen, The Netherlands
| | - Willem de Vries
- Division of Woman and Baby, Department of Neonatology, University Medical Centre Utrecht, Wilhelmina Children's Hospital, Utrecht University, Utrecht, The Netherlands
| | - Beate Horsberg Eriksen
- Department of Paediatrics, Møre and Romsdal Hospital Trust, Ålesund, Norway
- Clinical Research Unit, Norwegian University of Science and Technology, Trondheim, Norway
| | - Jean-Claude Fauchére
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Elisabeth M W Kooi
- Division of Neonatology, Department of Pediatrics, Beatrix Children's Hospital, University of Groningen, University Medical Centre, Groningen, The Netherlands
| | - Philip T Levy
- Department of Newborn Medicine, Boston Children's Hospital, Boston, MA, USA
- Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| | | | - Subhabrata Mitra
- Institute for Women's Health, University College London, London, UK
| | - Eirik Nestaas
- Institute of Clinical Medicine, Faculty of Medicine, University of Oslo, Oslo, Norway
- Clinic of Paediatrics and Adolescence, Akershus University Hospital, Lørenskog, Norway
| | - Heike Rabe
- Brighton and Sussex Medical School, University of Sussex, Brighton, UK
| | | | - Sheryle R Rogerson
- Newborn Research Centre, The Royal Women's Hospital, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, The University of Melbourne, Melbourne, VIC, Australia
| | - Marilena Savoia
- Neonatal Intensive Care Unit, S Maria Della Misericordia Hospital, Udine, Italy
| | | | - Arvind Sehgal
- Monash Newborn, Monash Children's Hospital, Melbourne, VIC, Australia
- Department of Paediatrics, Monash University, Melbourne, VIC, Australia
| | - Christoph E Schwarz
- Department of Neonatology, Center for Pediatric and Adolescent Medicine, University of Heidelberg, Heidelberg, Germany
| | - Ulrich Thome
- Division of Neonatology, Department of Pediatrics, University of Leipzig Medical Centre, Leipzig, Germany
| | - David van Laere
- Neonatal Intensive Care Unit, Universitair Ziekenhuis, Antwerp, Belgium
| | - Gabriela C Zaharie
- Neonatology Department, University of Medicine and Pharmacy, Iuliu Hatieganu, Cluj -Napoca, Romania
| | - Samir Gupta
- Department of Engineering, Durham University, Durham, UK
- Division of Neonatology, Department of Pediatrics, Sidra Medicine, Doha, Qatar
| |
Collapse
|
2
|
van der Hout-van der Jagt MB, Verweij EJT, Andriessen P, de Boode WP, Bos AF, Delbressine FLM, Eggink AJ, Erwich JJHM, Feijs LMG, Groenendaal F, Kramer BWW, Lely AT, Loop RFAM, Neukamp F, Onland W, Oudijk MA, te Pas AB, Reiss IKM, Schoberer M, Scholten RR, Spaanderman MEA, van der Ven M, Vermeulen MJ, van de Vosse FN, Oei SG. Interprofessional Consensus Regarding Design Requirements for Liquid-Based Perinatal Life Support (PLS) Technology. Front Pediatr 2022; 9:793531. [PMID: 35127593 PMCID: PMC8809135 DOI: 10.3389/fped.2021.793531] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 12/14/2021] [Indexed: 12/23/2022] Open
Abstract
Liquid-based perinatal life support (PLS) technology will probably be applied in a first-in-human study within the next decade. Research and development of PLS technology should not only address technical issues, but also consider socio-ethical and legal aspects, its application area, and the corresponding design implications. This paper represents the consensus opinion of a group of healthcare professionals, designers, ethicists, researchers and patient representatives, who have expertise in tertiary obstetric and neonatal care, bio-ethics, experimental perinatal animal models for physiologic research, biomedical modeling, monitoring, and design. The aim of this paper is to provide a framework for research and development of PLS technology. These requirements are considering the possible respective user perspectives, with the aim to co-create a PLS system that facilitates physiological growth and development for extremely preterm born infants.
Collapse
Affiliation(s)
- M. Beatrijs van der Hout-van der Jagt
- Department of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - E. J. T. Verweij
- Department of Obstetrics and Gynecology, Division of Fetal Therapy, Leiden University Medical Center (LUMC), Leiden, Netherlands
| | - Peter Andriessen
- Department of Neonatology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Applied Physics, School of Medical Physics and Engineering Eindhoven, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Willem P. de Boode
- Division of Neonatology, Department of Perinatology, Radboud University Medical Center, Radboud Institute for Health Sciences, Amalia Children's Hospital, Nijmegen, Netherlands
| | - Arend F. Bos
- Department of Neonatology, University Medical Center Groningen, University of Groningen, Beatrix Children's Hospital, Groningen, Netherlands
| | - Frank L. M. Delbressine
- Department of Industrial Design Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Alex J. Eggink
- Department of Obstetrics and Gynecology, Erasmus Medical Centre, Rotterdam, Netherlands
| | - Jan Jaap H. M. Erwich
- Department of Obstetrics and Gynecology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Loe M. G. Feijs
- Department of Industrial Design Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Floris Groenendaal
- Department of Neonatology, Utrecht University Medical Center, Utrecht, Netherlands
| | - Boris W. W. Kramer
- Department of Neonatology, Maastricht University Medical Center (MUMC), Maastricht, Netherlands
| | - A. Titia Lely
- Department of Obstetrics and Gynecology, Utrecht University Medical Center, Utrecht, Netherlands
| | - Rachel F. A. M. Loop
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Department of Industrial Design Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Franziska Neukamp
- Institute for Applied Medical Engineering and Clinic for Neonatology, University Hospital Aachen, Aachen, Germany
| | - Wes Onland
- Department of Neonatology, Amsterdam UMC, Amsterdam, Netherlands
| | - Martijn A. Oudijk
- Amsterdam Reproduction and Development Research Institute, Department of Obstetrics, Amsterdam UMC, University of Amsterdam, Amsterdam, Netherlands
| | - Arjan B. te Pas
- Department of Neonatology, Leiden University Medical Center (LUMC), Leiden, Netherlands
| | - Irwin K. M. Reiss
- Department of Neonatology, Erasmus Medical Centre, Rotterdam, Netherlands
| | - Mark Schoberer
- Institute for Applied Medical Engineering and Clinic for Neonatology, University Hospital Aachen, Aachen, Germany
| | - Ralph R. Scholten
- Department of Obstetrics and Gynecology, Radboud Medical Centre, Nijmegen, Netherlands
| | - Marc E. A. Spaanderman
- Department of Obstetrics and Gynecology, Radboud Medical Centre, Nijmegen, Netherlands
- Department of Obstetrics and Gynecology, Maastricht University Medical Center (MUMC), Maastricht, Netherlands
| | - Myrthe van der Ven
- Department of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Marijn J. Vermeulen
- Department of Neonatology, Erasmus Medical Centre, Rotterdam, Netherlands
- Care4Neo Foundation, Rotterdam, Netherlands
| | - Frans N. van de Vosse
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - S. Guid Oei
- Department of Obstetrics and Gynecology, Máxima Medical Centre, Veldhoven, Netherlands
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
3
|
Van Wyk L, Gupta S, Lawrenson J, de Boode WP. Accuracy and Trending Ability of Electrical Biosensing Technology for Non-invasive Cardiac Output Monitoring in Neonates: A Systematic Qualitative Review. Front Pediatr 2022; 10:851850. [PMID: 35372144 PMCID: PMC8968571 DOI: 10.3389/fped.2022.851850] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 02/14/2022] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Electrical biosensing technology (EBT) is an umbrella term for non-invasive technology utilizing the body's fluctuating resistance to electrical current flow to estimate cardiac output. Monitoring cardiac output in neonates may allow for timely recognition of hemodynamic compromise and allow for prompt therapy, thereby mitigating adverse outcomes. For a new technology to be safely used in the clinical environment for therapeutic decisions, it must be proven to be accurate, precise and be able to track temporal changes. The aim of this systematic review was to identify and analyze studies that describe the accuracy, precision, and trending ability of EBT to non-invasively monitor Left ventricular cardiac output and/or stroke volume in neonates. METHODS A qualitative systematic review was performed. Studies were identified from PubMed NCBI, SCOPUS, and EBSCOHost up to November 2021, where EBT technologies were analyzed in neonates, in comparison to a reference technology. Outcome measures were bias, limits of agreement, percentage error for agreement studies and data from 4-quadrant and polar plots for trending studies. Effect direction plots were used to present results. RESULTS Fifteen neonatal studies were identified, 14 for agreement and 1 for trending analysis. Only thoracic electrical biosensing technology (TEBT), with transthoracic echocardiography (TTE) as the comparator, studies were available for analyzes. High heterogeneity existed between studies. An equal number of studies showed over- and underestimation of left ventricular output parameters. All studies showed small bias, wide limits of agreement, with most studies having a percentage error >30%. Sub-analyses for respiratory support mode, cardiac anomalies and type of technology showed similar results. The single trending study showed poor concordance, high angular bias, and poor angular concordance. DISCUSSION Overall, TEBT shows reasonable accuracy, poor precision, and non-interchangeability with TTE. However, high heterogeneity hampered proper analysis. TEBT should be used with caution in the neonatal population for monitoring and determining therapeutic interventions. The use of TEBT trend monitoring has not been sufficiently studied and requires further evaluation in future trials.
Collapse
Affiliation(s)
- Lizelle Van Wyk
- Division Neonatology, Department of Pediatrics and Child Health, Stellenbosch University and Tygerberg Children's Hospital, Cape Town, South Africa
| | - Samir Gupta
- Department of Engineering and Medical Physics, Durham University, Durham, United Kingdom.,Division of Neonatology, Sidra Medicine, Doha, Qatar
| | - John Lawrenson
- Pediatric Cardiology Unit, Department of Pediatrics and Child Health, Stellenbosch University, Cape Town, South Africa
| | - Willem-Pieter de Boode
- Division of Neonatology, Department of Perinatology, Radboud University Medical Center, Radboud Institute for Health Sciences, Amalia Children's Hospital, Nijmegen, Netherlands
| |
Collapse
|
4
|
Chen J, He C, Yin J, Li J, Duan X, Cao Y, Sun L, Hu M, Li W, Li Q. Quantitative Analysis and Automated Lung Ultrasound Scoring for Evaluating COVID-19 Pneumonia With Neural Networks. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2507-2515. [PMID: 33798078 PMCID: PMC8864919 DOI: 10.1109/tuffc.2021.3070696] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 03/28/2021] [Indexed: 05/18/2023]
Abstract
As being radiation-free, portable, and capable of repetitive use, ultrasonography is playing an important role in diagnosing and evaluating the COVID-19 Pneumonia (PN) in this epidemic. By virtue of lung ultrasound scores (LUSS), lung ultrasound (LUS) was used to estimate the excessive lung fluid that is an important clinical manifestation of COVID-19 PN, with high sensitivity and specificity. However, as a qualitative method, LUSS suffered from large interobserver variations and requirement for experienced clinicians. Considering this limitation, we developed a quantitative and automatic lung ultrasound scoring system for evaluating the COVID-19 PN. A total of 1527 ultrasound images prospectively collected from 31 COVID-19 PN patients with different clinical conditions were evaluated and scored with LUSS by experienced clinicians. All images were processed via a series of computer-aided analysis, including curve-to-linear conversion, pleural line detection, region-of-interest (ROI) selection, and feature extraction. A collection of 28 features extracted from the ROI was specifically defined for mimicking the LUSS. Multilayer fully connected neural networks, support vector machines, and decision trees were developed for scoring LUS images using the fivefold cross validation. The model with 128×256 two fully connected layers gave the best accuracy of 87%. It is concluded that the proposed method could assess the ultrasound images by assigning LUSS automatically with high accuracy, potentially applicable to the clinics.
Collapse
|
5
|
Karbing DS, Rees SE, Jaffe MB. Journal of Clinical Monitoring and Computing 2016 end of year summary: respiration. J Clin Monit Comput 2017; 31:247-252. [PMID: 28255799 DOI: 10.1007/s10877-017-0008-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 02/23/2017] [Indexed: 12/30/2022]
Abstract
This paper reviews 16 papers or commentaries published in Journal of Clinical Monitoring and Computing in 2016, within the field of respiration. Papers were published covering peri- and post-operative monitoring of respiratory rate, perioperative monitoring of CO2, modeling of oxygen gas exchange, and techniques for respiratory monitoring.
Collapse
Affiliation(s)
- D S Karbing
- Respiratory and Critical Care (RCARE), Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.
| | - S E Rees
- Respiratory and Critical Care (RCARE), Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - M B Jaffe
- Cardiorespiratory Consulting, LLC, Cheshire, CT, USA
| |
Collapse
|
6
|
Tipping the Scales With Fluid Overload in Pediatric Bronchiolitis: When Will We and What Can We Learn From Here? Pediatr Crit Care Med 2017; 18:289-290. [PMID: 28257372 DOI: 10.1097/pcc.0000000000001076] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|