1
|
Chatterjee D, Silva SRP, Tiwari I. Lab-on-a chip electrochemical sensing platform for simultaneous, ultra-sensitive and on-spot detection of 4-aminosalicylic acid and 5-aminosalicylic acid based on synergistic potential of chitosan functionalized MWCNTs supported on Ni doped Bi 2S 3. CHEMOSPHERE 2025; 379:144425. [PMID: 40267767 DOI: 10.1016/j.chemosphere.2025.144425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2024] [Revised: 04/08/2025] [Accepted: 04/13/2025] [Indexed: 04/25/2025]
Abstract
Mesalamine or 5-aminosalicylic acid (5-ASA) and its isomer 4-aminosalicylic acid (4-ASA), well known key therapeutic agents used to treat inflammatory bowel diseases (IBDs) can pose toxicity risks upon unregulated consumption. However, their simultaneous real-time detection from physiological fluids like urine remains unexplored. This study presents an innovative electrochemical sensing platform using modified screen-printed electrodes capable of simultaneous detection of both the drugs by harnessing the synergistic potential of a novel nanocomposite comprising chitosan functionalized multi-walled carbon nanotubes and nickel doped bismuth sulphide. Comprehensive optical and microstructural characterization validate the modified sensor platform's morphological characteristics. The sensor was evaluated using CV and DPV, exhibiting notably low detection limits which is of the value 39.559 μM for 5-ASA and 85.21 μM for 4-ASA. Sensitivity was found to be 0.174 μA μM-1cm-2 for the linear dynamic range (LDR) of 50 μM-5750 μM for 5-ASA and 0.139 μA μM-1cm-2 for the linear dynamic range (LDR) of 100 μM-2200 μM for 4-ASA. Moreover, the adaptability of the sensor for integration into hand-held point-of-care devices for practical application has been demonstrated in this paper. Experimental validation using real urine samples underscores the sensor's impressive recovery rate of 98-99.6 % for 5-ASA and 95.12-99.24 % for 4-ASA and its capability of detecting target drugs even when present with typical urinary constituents as interferences. The real-world applicability of this sensing platform is further emphasized by conducting experiments on miniaturized hand-held device thus making it a promising tool for on-the-spot detection, offering substantial potential for future integration into point-of-care diagnostic devices to monitor patients requiring precise medical monitoring. Our approach offers unprecedented real-time identification capabilities of 4-ASA and 5-ASA which has not been explored before.
Collapse
Affiliation(s)
- Darshana Chatterjee
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi, 211005, India; Advanced Technology Institute, School of Computer Science and Electronic Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, United Kingdom.
| | - S Ravi P Silva
- Advanced Technology Institute, School of Computer Science and Electronic Engineering, Faculty of Engineering and Physical Sciences, University of Surrey, United Kingdom; Institute for Sustainability, University of Surrey, United Kingdom.
| | - Ida Tiwari
- Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi, 211005, India.
| |
Collapse
|
2
|
Singh AK, Agrahari S, Gautam RK, Tiwari I. A highly efficient NiCo 2O 4 decorated g-C 3N 4 nanocomposite for screen-printed carbon electrode based electrochemical sensing and adsorptive removal of fast green dye. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2024; 31:67339-67354. [PMID: 37837595 DOI: 10.1007/s11356-023-30373-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 10/06/2023] [Indexed: 10/16/2023]
Abstract
Herein, we demonstrate the preparation and application of NiCo2O4 decorated over a g-C3N4-based novel nanocomposite (NiCo2O4@g-C3N4). The prepared material was well characterized through several physicochemical techniques, including FT-IR, XRD, SEM, and TEM. The electrochemical characterizations via electrochemical impedance spectroscopy show the low electron transfer resistance of NiCo2O4@g-C3N4 owing to the successful incorporation of NiCo2O4 nanoparticles on the sheets of g-C3N4. NiCo2O4@g-C3N4 nanocomposite was employed in the fabrication of a screen-printed carbon electrode-based innovative electrochemical sensing platform and the adsorptive removal of a food dye, i.e., fast green FCF dye (FGD). The electrochemical oxidation of FGD at the developed NiCo2O4@g-C3N4 nanocomposite modified screen-printed carbon electrode (NiCo2O4@g-C3N4/SPCE) was observed at an oxidation potential of 0.65 V. A wide dual calibration range for electrochemical determination of FGD was successfully established at the prepared sensing platform, showing an excellent LOD of 0.13 µM and sensitivity of 0.6912 µA.µM-1.cm-2 through differential pulse voltammetry. Further, adsorbent dose, pH, contact time, and temperature were optimized to study the adsorption phenomena. The adsorption thermodynamics, isotherm, and kinetics were also investigated for efficient removal of FGD at NiCo2O4@g-C3N4-based adsorbents. The adsorption phenomenon of FGD on NiCo2O4@g-C3N4 was best fitted (R2 = 0.99) with the Langmuir and Henry model, and the corresponding value of Langmuir adsorption efficiency (qm) was 3.72 mg/g for the removal of FGD. The reaction kinetics for adsorption phenomenon were observed to be pseudo-second order. The sensitive analysis of FGD in a real sample was also studied.
Collapse
Affiliation(s)
- Ankit Kumar Singh
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Shreanshi Agrahari
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Ravindra Kumar Gautam
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India
| | - Ida Tiwari
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| |
Collapse
|
3
|
Delmo N, Pande I, Peltola E. Key role of adsorption site abundance in the direct electrochemical co-detection of estradiol and dopamine. DISCOVER NANO 2024; 19:134. [PMID: 39196483 PMCID: PMC11358574 DOI: 10.1186/s11671-024-04092-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Accepted: 08/22/2024] [Indexed: 08/29/2024]
Abstract
Estradiol (E2) is a hormone that influences various aspects of women's health. Beyond its reproductive functions, E2 impacts neurotransmitter systems such as dopamine (DA). Vertically aligned carbon nanofibers (VACNFs) have shown good sensitivity, selectivity against ascorbic acid (AA) and uric acid (UA), biocompatibility, and reduced fouling in DA sensing. In this study, we explore the use of Ti-Ni-CNF electrodes with CNFs grown for 5 min and 30 min for the direct electrochemical co-detection of E2 and DA. The longer growth time led to a 142% increase in average CNF length and a 36% larger electroactive surface area. In E2 detection, the electrodes demonstrate a wide linear range of 0.05-10 µM and sensitivity of 0.016 and 0.020 µA/µM for Ti-Ni-CNF-5 min and Ti-Ni-CNF-30 min, respectively. The sensor performance remains largely unaffected even in the presence of other steroid hormones such as progesterone and testosterone. Co-detection of equimolar E2 and DA shows promising peak separation of 0.34 ± 0.01 V and repeatability after 10 measurements. A notable improvement in the E2/DA peak current ratio, from 0.53 ± 0.07 to 0.81 ± 0.16, was achieved with the increased CNF length. Our results demonstrate the influence of adsorption sites in electrochemical detection, especially for analytes such as E2 and DA that both rely on adsorption for oxidation. While detecting small and fluctuating physiological concentrations remains a challenge, these findings can be used in choosing and fabricating electrode materials for more accurate and accessible continuous hormone measurements, including the possibility of multianalyte sensing platforms.
Collapse
Affiliation(s)
- Naela Delmo
- Department of Mechanical and Materials Engineering, Faculty of Technology, University of Turku, 20500, Turku, Finland
| | - Ishan Pande
- Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 00076, Aalto, Finland
| | - Emilia Peltola
- Department of Mechanical and Materials Engineering, Faculty of Technology, University of Turku, 20500, Turku, Finland.
- Department of Electrical Engineering and Automation, School of Electrical Engineering, Aalto University, 00076, Aalto, Finland.
| |
Collapse
|
4
|
de Faria LV, Villafuerte LM, do Nascimento SFL, de Sá IC, Peixoto DA, Ribeiro RSDA, Nossol E, Lima TDM, Semaan FS, Pacheco WF, Dornellas RM. 3D-printed electrodes using graphite/carbon nitride/polylactic acid composite material: A greener platform for detection of amaranth dye in food samples. Food Chem 2024; 442:138497. [PMID: 38271904 DOI: 10.1016/j.foodchem.2024.138497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 12/27/2023] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
The production of sustainable materials with properties aimed at the additive manufacturing of electrochemical sensors has gained prestige in the scientific scenario. Here, a novel lab-made composite material using graphite (G) and carbon nitride (C3N4) embedded into polylactic acid (PLA) biopolymer is proposed to produce 3D-printed electrodes. PLA offers printability and mechanical stability in this composition, while G and C3N4 provide electrical properties and electrocatalytic sites, respectively. Characterizations by Raman and infrared spectroscopies and Energy Dispersive X-rays indicated that the G/C3N4/PLA composite was successfully obtained, while electron microscopy images revealed non-homogeneous rough surfaces. Better electrochemical properties were achieved when the G/C3N4/PLA proportion (35:5:60) was used. As a proof of concept, amaranth (AMR), a synthetic dye, was selected as an analyte, and a fast method using square wave voltammetry was developed. Utilizing the 3D-printed G/C3N4/PLA electrode, a more comprehensive linear range (0.2 to 4.2 μmol/L), a 5-fold increase in sensitivity (9.83 μmol-1 L μA), and better limits of detection (LOD = 0.06 μmol/L) and quantification (LOQ = 0.18 μmol/L) were achieved compared to the G/PLA electrode. Samples of jelly, popsicles, isotonic drinks, and food flavoring samples were analyzed, and similar results to those obtained by UV-vis spectrometry confirmed the method's reliability. Therefore, the described sensor is a simple, cost-effective alternative for assessing AMR in routine food analysis.
Collapse
Affiliation(s)
- Lucas V de Faria
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil.
| | - Luana M Villafuerte
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Suéllen F L do Nascimento
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Igor C de Sá
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Diego A Peixoto
- Instituto de Química, Universidade Federal de Uberlândia, 38408-100 Uberlândia-MG, Brazil
| | - Ruan S de A Ribeiro
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Edson Nossol
- Instituto de Química, Universidade Federal de Uberlândia, 38408-100 Uberlândia-MG, Brazil
| | - Thiago de M Lima
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Felipe S Semaan
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Wagner F Pacheco
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil
| | - Rafael M Dornellas
- Departamento de Química Analítica, Instituto de Química, Universidade Federal Fluminense, 24020-141 Niterói-RJ, Brazil.
| |
Collapse
|
5
|
Erk N, Kurtay G, Bouali W, Sakal ZG, Genç AA, Erbaş Z, Soylak M. Electrochemical Detection of Melphalan in Biological Fluids Using a g-C 3N 4@ND-COOH@MoSe 2 Modified Electrode Complemented by Molecular Docking Studies with Cellular Tumor Antigen P53. ACS OMEGA 2024; 9:21058-21070. [PMID: 38764632 PMCID: PMC11097377 DOI: 10.1021/acsomega.4c00558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 04/04/2024] [Accepted: 04/16/2024] [Indexed: 05/21/2024]
Abstract
Melphalan (Mel) is a potent alkylating agent utilized in chemotherapy treatments for a diverse range of malignancies. The need for its accurate and timely detection in pharmaceutical preparations and biological samples is paramount to ensure optimized therapeutic efficacy and to monitor treatment progression. To address this critical need, our study introduced a cutting-edge electrochemical sensor. This device boasts a uniquely modified electrode crafted from graphitic carbon nitride (g-C3N4), decorated with activated nanodiamonds (ND-COOH) and molybdenum diselenide (MoSe2), and specifically designed to detect Mel with unparalleled precision. Our rigorous testing employed advanced techniques such as cyclic voltammetry and differential pulse voltammetry. The outcomes were promising; the sensor consistently exhibited a linear response in the range of 0.5 to 12.5 μM. Even more impressively, the detection threshold was as low as 0.03 μM, highlighting its sensitivity. To further enhance our understanding of Mel's biological interactions, we turned to molecular docking studies. These studies primarily focused on Mel's interaction dynamics with the cellular tumor antigen P53, revealing a binding affinity of -5.0 kcal/mol. A fascinating observation was made when Mel was covalently conjugated with nanodiamond-COOH (ND-COOH). This conjugation resulted in a binding affinity that surged to -10.9 kcal/mol, clearly underscoring our sensor's superior detection capabilities. This observation also reinforced the wisdom behind incorporating ND-COOH in our electrode design. In conclusion, our sensor not only stands out in terms of sensitivity but also excels in selectivity and accuracy. By bridging electrochemical sensing with computational insights, our study illuminates Mel's intricate behavior, driving advancements in sensor technology and potentially revolutionizing cancer therapeutic strategies.
Collapse
Affiliation(s)
- Nevin Erk
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560 Ankara, Turkey
| | - Gülbin Kurtay
- Hacettepe University, Faculty of Sciences, Department of Chemistry, 06800 Ankara, Turkey
| | - Wiem Bouali
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560 Ankara, Turkey
- Ankara University, Graduate School of Health Sciences, 06110 Ankara, Turkey
| | - Zeyneb Gülsüm Sakal
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560 Ankara, Turkey
- Ankara University, Graduate School of Health Sciences, 06110 Ankara, Turkey
| | - Asena Ayşe Genç
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, 06560 Ankara, Turkey
- Ankara University, Graduate School of Health Sciences, 06110 Ankara, Turkey
| | - Zeliha Erbaş
- Yozgat Bozok University, Science and Technology Application and Research Center, 66200 Yozgat, Turkey
- Erciyes University, Technology Research & Application Center (TAUM), 38039 Kayseri, Turkey
| | - Mustafa Soylak
- Erciyes University, Technology Research & Application Center (TAUM), 38039 Kayseri, Turkey
- Turkish Academy of Sciences (TUBA), Çankaya, Ankara 06670, Turkey
| |
Collapse
|
6
|
Agrahari S, Singh AK, Gautam RK, Tiwari I. Electrochemical oxidation and sensing of para benzoquinone using a novel SPE based disposable sensor. CHEMOSPHERE 2023; 342:140078. [PMID: 37714484 DOI: 10.1016/j.chemosphere.2023.140078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/31/2023] [Accepted: 09/04/2023] [Indexed: 09/17/2023]
Abstract
Para-benzoquinone (PBQ) is an emerging micro-contaminant owing to its chronic toxicity to plants and animals as well as its potential to induce cytotoxicity in primary rat hepatocytes and kidney cell injury. Hence, it is of utmost importance to monitor this contaminant in industrial wastewater and groundwater. In this article, we devised a unique disposable sensor that is based on a screen-printed electrode using MnO2@Co-Ni MOFs/fMWCNTs nanocomposite and is able to detect PBQ. The as-produced nanocomposite was prepared via ultrasonic assisted reflux condition and thoroughly examined by several physicochemical characterisation methods such as SEM, EDX, TEM, Raman, AFM, UV-visible, and FT-IR. Moreover, electrochemical methods like CV, DPV, EIS, and chronoamperometry were used for detecting PBQ on MnO2@Co-Ni MOFs/fMWCNTs/SPCE. Sensor performance has been investigated thoroughly and optimized to enhance the analytical potential of the fabricated sensor. DPV analysis was done on MnO2@Co-Ni MOFs/fMWCNTs that exhibit high selectivity, low peak potential, a broader linear detection range (0.005 mM-30 mM), and a LOD of 0.0027 ± 0.0005 mM. The designed electrode has shown remarkable reproducibility and excellent repeatability, with relative standard deviations of 0.12%, and 0.17%, respectively. Additionally, MnO2@Co-Ni MOFs/fMWCNTs/SPCE have been used to analyse PBQ in industrial wastewater samples, and the results have shown a significant level of recovery between 96.91 and 105.67%. Moreover, the PBQ sensor displays high applicability and was verified via the use of HPLC techniques. This disposable sensor is quick, easy, and cost-effective, so it can be useful in the future for analysing other phenolic contaminants present in environmental samples.
Collapse
Affiliation(s)
- Shreanshi Agrahari
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| | - Ankit Kumar Singh
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| | - Ravindra Kumar Gautam
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| | - Ida Tiwari
- Department of Chemistry (Centre of Advanced Study), Institute of Science, Banaras Hindu University, Varanasi, 221005, India.
| |
Collapse
|
7
|
Ivanišević I. The Role of Silver Nanoparticles in Electrochemical Sensors for Aquatic Environmental Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:3692. [PMID: 37050752 PMCID: PMC10099384 DOI: 10.3390/s23073692] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/30/2023] [Accepted: 03/31/2023] [Indexed: 06/19/2023]
Abstract
With rapidly increasing environmental pollution, there is an urgent need for the development of fast, low-cost, and effective sensing devices for the detection of various organic and inorganic substances. Silver nanoparticles (AgNPs) are well known for their superior optoelectronic and physicochemical properties, and have, therefore, attracted a great deal of interest in the sensor arena. The introduction of AgNPs onto the surface of two-dimensional (2D) structures, incorporation into conductive polymers, or within three-dimensional (3D) nanohybrid architectures is a common strategy to fabricate novel platforms with improved chemical and physical properties for analyte sensing. In the first section of this review, the main wet chemical reduction approaches for the successful synthesis of functional AgNPs for electrochemical sensing applications are discussed. Then, a brief section on the sensing principles of voltammetric and amperometric sensors is given. The current utilization of silver nanoparticles and silver-based composite nanomaterials for the fabrication of voltammetric and amperometric sensors as novel platforms for the detection of environmental pollutants in water matrices is summarized. Finally, the current challenges and future directions for the nanosilver-based electrochemical sensing of environmental pollutants are outlined.
Collapse
Affiliation(s)
- Irena Ivanišević
- Department of General and Inorganic Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, 10000 Zagreb, Croatia
| |
Collapse
|