Matuleviciute-Stojanoska A, Sautier J, Bauer V, Nuessel M, Nizhnikava V, Stumpf C, Klink T. Coronary CT angiography: First comparison of model-based and hybrid iterative reconstruction with the reference standard invasive catheter angiography for CAD-RADS reporting. Eur J Radiol Open 2024; 13:100612. [PMID: 39639859 PMCID: PMC11617778 DOI: 10.1016/j.ejro.2024.100612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2024] [Revised: 10/16/2024] [Accepted: 11/10/2024] [Indexed: 12/07/2024] Open
Abstract
Background The purpose of this study was to compare CCTA images generated using HIR and IMR algorithm with the reference standard ICA, and to determine to what extend further improvements of IMR over HIR can be expected. Methods This retrospective study included 60 patients with low to intermediate CAD risk, who underwent coronary CTA (with HIR and IMR) and ICA. ICA was used as reference standard. Two independent and blinded readers evaluated 2226 segments, classifying stenosis with CAD-RADS (significant stenosis ≥3). Image quality was assessed with a 5-point scale, SNR in the ascending aorta, and FWHM of proximal LCA calibers. The impact of image noise, radiation dose, and BMI on diagnostic accuracy was evaluated using ROC curves and Fisher's Exact Test. Quantitative plaque analysis was performed on 28 plaques. Results IMR showed higher image quality than HIR (IMR 4.4, HIR 3.97, p<0.001) with better SNR (21.4 vs. 13.28, p<0.001) and FWHM (4.44 vs. 4.55, p=0.003). IMR had better diagnostic accuracy (ROC AUC 0.967 vs. 0.948, p=0.16, performed better at higher radiation doses (p=0.02) and showed a larger minimum lumen area (p=0.022 and p=0.046). Conclusion IMR offers significantly superior image quality of CCTA, more precise measurements, and a stronger positive correlation with ICA. The overall diagnostic accuracy may be superior with IMR, although the differences were not statistically significant. However, in patients who are exposed to higher radiation doses during CCTA due to their constitution, IMR enables significantly better diagnostic accuracy than HIR thus providing a specific benefit for obese patients.
Collapse
Affiliation(s)
- Aiste Matuleviciute-Stojanoska
- Institute of Diagnostic and Interventional Radiology, Klinikum Bayreuth, Medical Campus Oberfranken, Friedrich Alexander University Erlangen, Bayreuth, Germany
| | - Julia Sautier
- Institute of Diagnostic and Interventional Radiology, Klinikum Bayreuth, Medical Campus Oberfranken, Friedrich Alexander University Erlangen, Bayreuth, Germany
| | - Verena Bauer
- Department of Cardiology, Klinikum Bayreuth, Medical Campus Oberfranken, Friedrich Alexander University Erlangen, Bayreuth, Germany
| | - Martin Nuessel
- Institute of Diagnostic and Interventional Radiology, Klinikum Bayreuth, Medical Campus Oberfranken, Friedrich Alexander University Erlangen, Bayreuth, Germany
| | - Volha Nizhnikava
- Department of Radiology, Kantonsspital Graubuenden, Chur, Switzerland
| | - Christian Stumpf
- Department of Cardiology, Klinikum Bayreuth, Medical Campus Oberfranken, Friedrich Alexander University Erlangen, Bayreuth, Germany
| | - Thorsten Klink
- Institute of Diagnostic and Interventional Radiology, Klinikum Bayreuth, Medical Campus Oberfranken, Friedrich Alexander University Erlangen, Bayreuth, Germany
| |
Collapse
|
2
|
Fan Y, Qin T, Sun Q, Wang M, Liang B. A Review of Factors Affecting Radiation Dose and Image Quality in Coronary CTA Performed with Wide-Detector CT. Tomography 2024; 10:1730-1743. [PMID: 39590936 PMCID: PMC11598146 DOI: 10.3390/tomography10110127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2024] [Revised: 10/19/2024] [Accepted: 10/22/2024] [Indexed: 11/28/2024] Open
Abstract
Compared with traditional invasive coronary angiography (ICA), coronary CT angiography (CCTA) has the advantages of being rapid, economical, and minimally invasive. The wide-detector CT, with its superior temporal resolution and robust three-dimensional reconstruction technology, thus enables CCTA in patients with high heart rates and arrhythmias, leading to a high potential for clinical application. This paper systematically summarizes wide-detector CT hardware configurations of various vendors routinely used for CCTA examinations and reviews the effects of patient heart rate and heart rate variability, scanning modality, reconstruction algorithms, tube voltage, and scanning field of view on image quality and radiation dose. In addition, novel technologies in the field of CT applied to CCTA examinations are also presented. Since this examination has a diagnostic accuracy that is highly consistent with ICA, it can be further used as a routine examination tool for coronary artery disease in clinical practice.
Collapse
Affiliation(s)
- Yihan Fan
- School of Medical Imaging, Bengbu Medical University, Bengbu 233000, China; (Y.F.); (T.Q.); (Q.S.)
| | - Tian Qin
- School of Medical Imaging, Bengbu Medical University, Bengbu 233000, China; (Y.F.); (T.Q.); (Q.S.)
| | - Qingting Sun
- School of Medical Imaging, Bengbu Medical University, Bengbu 233000, China; (Y.F.); (T.Q.); (Q.S.)
| | - Mengting Wang
- The Second Hospital of Anhui Medical University, Hefei 230000, China;
| | - Baohui Liang
- School of Medical Imaging, Bengbu Medical University, Bengbu 233000, China; (Y.F.); (T.Q.); (Q.S.)
| |
Collapse
|
3
|
Ryu JK, Kim KH, Otgonbaatar C, Kim DS, Shim H, Seo JW. Improved stent sharpness evaluation with super-resolution deep learning reconstruction in coronary CT angiography. Br J Radiol 2024; 97:1286-1294. [PMID: 38733576 PMCID: PMC11186566 DOI: 10.1093/bjr/tqae094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 02/27/2024] [Accepted: 05/04/2024] [Indexed: 05/13/2024] Open
Abstract
OBJECTIVES This study aimed to assess the impact of super-resolution deep learning reconstruction (SR-DLR) on coronary CT angiography (CCTA) image quality and blooming artifacts from coronary artery stents in comparison to conventional methods, including hybrid iterative reconstruction (HIR) and deep learning-based reconstruction (DLR). METHODS A retrospective analysis included 66 CCTA patients from July to November 2022. Major coronary arteries were evaluated for image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Stent sharpness was quantified using 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD). Qualitative analysis employed a 5-point scoring system to assess overall image quality, image noise, vessel wall, and stent structure. RESULTS SR-DLR demonstrated significantly lower image noise compared to HIR and DLR. SNR and CNR were notably higher in SR-DLR. Stent ERS was significantly improved in SR-DLR, with mean ERD values of 0.70 ± 0.20 mm for SR-DLR, 1.13 ± 0.28 mm for HIR, and 0.85 ± 0.26 mm for DLR. Qualitatively, SR-DLR scored higher in all categories. CONCLUSIONS SR-DLR produces images with lower image noise, leading to improved overall image quality, compared with HIR and DLR. SR-DLR is a valuable image reconstruction algorithm for enhancing the spatial resolution and sharpness of coronary artery stents without being constrained by hardware limitations. ADVANCES IN KNOWLEDGE The overall image quality was significantly higher in SR-DLR, resulting in sharper coronary artery stents compared to HIR and DLR.
Collapse
Affiliation(s)
- Jae-Kyun Ryu
- Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea
| | - Ki Hwan Kim
- Department of Radiology, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea
| | | | - Da Som Kim
- Department of Radiology, Inje University Busan Paik Hospital, Inje University College of Medicine, Busan, Republic of Korea
| | - Hackjoon Shim
- Medical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea
- ConnectAI Research Center, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jung Wook Seo
- Department of Radiology, Inje University Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea
| |
Collapse
|
4
|
Guido G, Polici M, Nacci I, Bozzi F, De Santis D, Ubaldi N, Polidori T, Zerunian M, Bracci B, Laghi A, Caruso D. Iterative Reconstruction: State-of-the-Art and Future Perspectives. J Comput Assist Tomogr 2023; 47:244-254. [PMID: 36728734 DOI: 10.1097/rct.0000000000001401] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
ABSTRACT Image reconstruction processing in computed tomography (CT) has evolved tremendously since its creation, succeeding at optimizing radiation dose while maintaining adequate image quality. Computed tomography vendors have developed and implemented various technical advances, such as automatic noise reduction filters, automatic exposure control, and refined imaging reconstruction algorithms.Focusing on imaging reconstruction, filtered back-projection has represented the standard reconstruction algorithm for over 3 decades, obtaining adequate image quality at standard radiation dose exposures. To overcome filtered back-projection reconstruction flaws in low-dose CT data sets, advanced iterative reconstruction algorithms consisting of either backward projection or both backward and forward projections have been developed, with the goal to enable low-dose CT acquisitions with high image quality. Iterative reconstruction techniques play a key role in routine workflow implementation (eg, screening protocols, vascular and pediatric applications), in quantitative CT imaging applications, and in dose exposure limitation in oncologic patients.Therefore, this review aims to provide an overview of the technical principles and the main clinical application of iterative reconstruction algorithms, focusing on the strengths and weaknesses, in addition to integrating future perspectives in the new era of artificial intelligence.
Collapse
Affiliation(s)
- Gisella Guido
- From the Department of Surgical Medical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit, Sant'Andrea University Hospital, Rome, Italy
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Du Y, Wang YN, Wang Q, Qi XH, Shi GF, Jia LT, Wang XM, Shi JB, Liu FY, Wang LJ, Liu X. A comparison of the use of contrast media with different iodine concentrations for enhanced computed tomography. Front Physiol 2023; 14:1141135. [PMID: 37064921 PMCID: PMC10101225 DOI: 10.3389/fphys.2023.1141135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 03/03/2023] [Indexed: 04/18/2023] Open
Abstract
Objective: In this study, we compared the enhancement of blood vessels and liver parenchyma on enhanced computed tomography (CT) of the upper abdomen with two concentrations of contrast media (400 and 300 mg I/mL) based on similar iodine delivery rate (IDR) of 0.88 and 0.9 g I/s and iodine load of 450 mg I/kg. Methods: We randomly assigned 160 patients into two groups: iomeprol 400 mg I/mL (A group) and iohexol 300 mg I/mL (B group). The CT attenuation values of the main anatomical structures in the two groups with different scanning phases were measured and the image quality of the two groups was analyzed and compared. The peak pressure and local discomfort (including fever and pain) during contrast medium injection were recorded. Results: The mean attenuation value of the abdominal aorta was 313.6 ± 29.6 in the A group and 322.4 ± 30.1 in the B group during the late arterial phase (p = 0.8). Meanwhile, the mean enhancement values of the portal vein were 176.2 ± 19.3 and 165.9 ± 24.5 in the A and B groups, respectively, during the portal venous phase (p = 0.6). The mean CT values of liver parenchyma were 117.1 ± 15.3 and 108.8 ± 18.7 in the A and B groups, respectively, during the portal venous phase (p = 0.9). There was no statistical difference in image quality, peak injection pressure (psi), and local discomfort between the two groups (p > 0.05). Conclusion: When a similar IDR and the same iodine load are used, CT images with different concentrations of contrast media have the same subjective and objective quality, and can meet the diagnostic needs.
Collapse
|
6
|
He W, Chen X, Hu R, Sun W, Tan W. Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging. Front Surg 2022; 9:862697. [PMID: 35449554 PMCID: PMC9018106 DOI: 10.3389/fsurg.2022.862697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 02/21/2022] [Indexed: 11/13/2022] Open
Abstract
Objective To explore the influence of a contrast agent injection scheme customized by dual-source CT based on automatic tube voltage technology on coronary imaging image quality and radiation dose. Methods A total of 205 patients who underwent coronary CT angiography (CCTA) in our hospital from June 2021 to September 2021 were selected. 105 patients in the control group who underwent routine scanning according to body mass (BMI) and 100 patients in the observation group who set tube voltage and contrast agent dosage according to automatic tube voltage selection technology. CT values of the aortic root (AO); left anterior descending (LAD) branch; proximal, middle, and distal segments of the right coronary artery (RCA); and proximal and distal segments of left circumflex (LCX) branch were measured. We calculated the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the image. Image quality scoring and effective dose (ED) calculation were carried out. Results There was no significant difference in the CT value, SNR value, and CNR value of each part of the artery between the two groups (P > 0.05). Image quality scores of the control group and the observation group were 1.28 ± 0.25 and 1.25 ± 0.23, respectively, and there was no significant difference in scores (P > 0.05). In the control group, the dosage of comparator was 43.81 ± 6.74 ml, and the ED was 4.92 ± 1.26 mSv. The dosage of contrast agent in the observation group was 34.23 ± 6.39 ml, and ED was 3.05 ± 0.94 mSv. The dosage of contrast agent and ED in the observation group were lower than those in the control group (P < 0.05). Conclusion The contrast agent injection scheme customized by dual-source CT based on automatic tube voltage technology can meet the clinical requirements of coronary image quality, reduce the radiation dose and contrast agent consumption, and help doctors choose a more accurate and reasonable examination scheme, which has certain clinical application value.
Collapse
Affiliation(s)
- Weiling He
- Department of Radiology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Xin Chen
- Diagnostic Radiology Department, Hunan Cancer Hospital, Changsha, China
| | - Rui Hu
- Interventional Vascular Surgery Department, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Wenjie Sun
- Department of Radiology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Weili Tan
- Diagnostic Radiology Department, Hunan Cancer Hospital, Changsha, China
- *Correspondence: Weili Tan
| |
Collapse
|
7
|
Albano D, Bruno F, Agostini A, Angileri SA, Benenati M, Bicchierai G, Cellina M, Chianca V, Cozzi D, Danti G, De Muzio F, Di Meglio L, Gentili F, Giacobbe G, Grazzini G, Grazzini I, Guerriero P, Messina C, Micci G, Palumbo P, Rocco MP, Grassi R, Miele V, Barile A. Dynamic contrast-enhanced (DCE) imaging: state of the art and applications in whole-body imaging. Jpn J Radiol 2022; 40:341-366. [PMID: 34951000 DOI: 10.1007/s11604-021-01223-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 11/17/2021] [Indexed: 12/18/2022]
Abstract
Dynamic contrast-enhanced (DCE) imaging is a non-invasive technique used for the evaluation of tissue vascularity features through imaging series acquisition after contrast medium administration. Over the years, the study technique and protocols have evolved, seeing a growing application of this method across different imaging modalities for the study of almost all body districts. The main and most consolidated current applications concern MRI imaging for the study of tumors, but an increasing number of studies are evaluating the use of this technique also for inflammatory pathologies and functional studies. Furthermore, the recent advent of artificial intelligence techniques is opening up a vast scenario for the analysis of quantitative information deriving from DCE. The purpose of this article is to provide a comprehensive update on the techniques, protocols, and clinical applications - both established and emerging - of DCE in whole-body imaging.
Collapse
Affiliation(s)
- Domenico Albano
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- IRCCS Istituto Ortopedico Galeazzi, Milan, Italy
- Dipartimento Di Biomedicina, Neuroscienze E Diagnostica Avanzata, Sezione Di Scienze Radiologiche, Università Degli Studi Di Palermo, via Vetoio 1L'Aquila, 67100, Palermo, Italy
| | - Federico Bruno
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy.
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy.
| | - Andrea Agostini
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Clinical, Special and Dental Sciences, Department of Radiology, University Politecnica delle Marche, University Hospital "Ospedali Riuniti Umberto I - G.M. Lancisi - G. Salesi", Ancona, Italy
| | - Salvatore Alessio Angileri
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Radiology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Massimo Benenati
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Dipartimento di Diagnostica per Immagini, Fondazione Policlinico Universitario A. Gemelli IRCCS, Oncologia ed Ematologia, RadioterapiaRome, Italy
| | - Giulia Bicchierai
- Diagnostic Senology Unit, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Michaela Cellina
- Department of Radiology, ASST Fatebenefratelli Sacco, Ospedale Fatebenefratelli, Milan, Italy
| | - Vito Chianca
- Ospedale Evangelico Betania, Naples, Italy
- Clinica Di Radiologia, Istituto Imaging Della Svizzera Italiana - Ente Ospedaliero Cantonale, Lugano, Switzerland
| | - Diletta Cozzi
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Emergency Radiology, Careggi University Hospital, Florence, Italy
| | - Ginevra Danti
- Department of Emergency Radiology, Careggi University Hospital, Florence, Italy
| | - Federica De Muzio
- Department of Medicine and Health Sciences "Vincenzo Tiberio", University of Molise, Campobasso, Italy
| | - Letizia Di Meglio
- Postgraduation School in Radiodiagnostics, University of Milan, Milan, Italy
| | - Francesco Gentili
- Unit of Diagnostic Imaging, Azienda Ospedaliera Universitaria Senese, Siena, Italy
| | - Giuliana Giacobbe
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Precision Medicine, University of Campania "L. Vanvitelli", Naples, Italy
| | - Giulia Grazzini
- Department of Radiology, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Irene Grazzini
- Department of Radiology, Section of Neuroradiology, San Donato Hospital, Arezzo, Italy
| | - Pasquale Guerriero
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Medicine and Health Sciences "Vincenzo Tiberio", University of Molise, Campobasso, Italy
| | | | - Giuseppe Micci
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Dipartimento Di Biomedicina, Neuroscienze E Diagnostica Avanzata, Sezione Di Scienze Radiologiche, Università Degli Studi Di Palermo, via Vetoio 1L'Aquila, 67100, Palermo, Italy
| | - Pierpaolo Palumbo
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Abruzzo Health Unit 1, Department of diagnostic Imaging, Area of Cardiovascular and Interventional Imaging, L'Aquila, Italy
| | - Maria Paola Rocco
- Department of Precision Medicine, University of Campania "L. Vanvitelli", Naples, Italy
| | - Roberto Grassi
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Precision Medicine, University of Campania "L. Vanvitelli", Naples, Italy
| | - Vittorio Miele
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Radiology, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Antonio Barile
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, Milan, Italy
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, L'Aquila, Italy
| |
Collapse
|
8
|
Vecsey-Nagy M, Jermendy ÁL, Suhai FI, Panajotu A, Csőre J, Borzsák S, Fontanini DM, Kolossváry M, Vattay B, Boussoussou M, Csobay-Novák C, Merkely B, Maurovich-Horvat P, Szilveszter B. Model-based adaptive filter for a dedicated cardiovascular CT scanner: Assessment of image noise, sharpness and quality. Eur J Radiol 2021; 145:110032. [PMID: 34800835 DOI: 10.1016/j.ejrad.2021.110032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Revised: 10/29/2021] [Accepted: 11/12/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR) are ubiquitously applied in the reconstruction of coronary CT angiography (CCTA) datasets. However, currently no data is available on the impact of a model-based adaptive filter (MBAF2), recently developed for a dedicated cardiac scanner. PURPOSE Our aim was to determine the effect of MBAF2 on subjective and objective image quality parameters of coronary arteries on CCTA. METHODS Images of 102 consecutive patients referred for CCTA were evaluated. Four reconstructions of coronary images (FBP, ASIR, MBAF2, ASIR + MBAF2) were co-registered and cross-section were assessed for qualitative (graininess, sharpness, overall image quality) and quantitative [image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR)] image quality parameters. Image noise and signal were measured in the aortic root and the left main coronary artery, respectively. Graininess, sharpness, and overall image quality was assessed on a 4-point Likert scale. RESULTS As compared to FBP, ASIR, and MBAF2, ASIR + MBAF2 resulted in reduced image noise [53.1 ± 12.3, 30.6 ± 8.5, 36.3 ± 4.2, 26.3 ± 4.0 Hounsfield units (HU), respectively; p < 0.001], improved SNR (8.4 ± 2.6, 14.1 ± 3.6, 11.8 ± 2.3, 16.3 ± 3.3 HU, respectively; p < 0.001) and CNR (9.4 ± 2.7, 15.9 ± 4.0, 13.3 ± 2.5, 18.3 ± 3.5 HU, respectively; p < 0.001). No difference in sharpness was observed amongst the reconstructions (p = 0.08). Although ASIR + MBAF2 was non-superior to ASIR regarding overall image quality (p = 0.99), it performed better than FBP (p < 0.001) and MBAF2 (p < 0.001) alone. CONCLUSION The combination of ASIR and MBAF2 resulted in reduced image noise and improved SNR and CNR. The implementation of MBAF2 in clinical practice may result in improved noise reduction performance and could potentiate radiation dose reduction.
Collapse
Affiliation(s)
- Milán Vecsey-Nagy
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary.
| | - Ádám Levente Jermendy
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Ferenc Imre Suhai
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Alexisz Panajotu
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Judit Csőre
- Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Sarolta Borzsák
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | | | - Márton Kolossváry
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Borbála Vattay
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Melinda Boussoussou
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Csaba Csobay-Novák
- Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Béla Merkely
- Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| | - Pál Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary; Medical Imaging Centre, Semmelweis University, 78.a Ulloi av., 1082 Budapest, Hungary
| | - Bálint Szilveszter
- MTA-SE Cardiovascular Imaging Research Group, Heart and Vascular Center, Semmelweis University, 68. Varosmajor st., 1122 Budapest, Hungary
| |
Collapse
|
9
|
Zhang Q, Mi H, Shi X, Li W, Guo S, Wang P, Suo H, Wang Z, Jin S, Yan F, Niu Y, Xian J. Higher Iodine Concentration Enables Radiation Dose Reduction in Coronary CT Angiography. Acad Radiol 2021; 28:1072-1080. [PMID: 32553279 DOI: 10.1016/j.acra.2020.05.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 05/13/2020] [Accepted: 05/13/2020] [Indexed: 01/01/2023]
Abstract
RATIONALE AND OBJECTIVES To test whether higher iodine concentration together with higher noise level could lead to a further dose reduction in an already low dose coronary CT angiography (CCTA) protocol without comprising image quality. MATERIALS AND METHODS One hundred eighty patients with suspected coronary artery disease (CAD) were randomly assigned into three groups: (a) conventional dose (CD) group, 100 kV with a noise index (NI) of 25 and iohexol (350 mg I/ml); (b) low dose (LD) group, 80 kV with a NI of 25 and iohexol (350 mg I/ml); (c) further low dose (FLD) group, 80 kV with a NI of 30 and iomeprol (400 mg I/ml). The volume and injection rate of contrast medium were fixed at 60 ml and 5 ml/s. The radiation dose (volume CT dose index [CTDIvol], dose length product [DLP], and effective dose [ED]) were recorded. For image quality, both quantitative (enhancement, noise, signal-to-noise ratio [SNR], and contrast-to-noise ratio [CNR]) and qualitative indices were assessed. RESULTS Compared to the CD group, ED was reduced by 16% and 42% in the LD and FLD groups, respectively (p < 0.05). Qualitative analysis showed no significant difference among the 3 groups (p > 0.05), while quantitative analysis revealed significantly higher attenuation in the LD and FLD groups. Signal-to-noise ratios and CNRs of the LD and FLD groups were significantly higher except for the CNR at the left circumflex branch of the FLD group (p < 0.05). CONCLUSION Increasing iodine concentration and noise level may further reduce the radiation dose by 26% on top of a 16% reduction from 100 kV to 80 kV without image quality compromise.
Collapse
Affiliation(s)
- Qing Zhang
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Haifeng Mi
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Xubo Shi
- Department of Cardiology, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China
| | - Wei Li
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Senlin Guo
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Ping Wang
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Hongna Suo
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Ziyi Wang
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Shanshan Jin
- Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, P.R. China
| | - Fei Yan
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Yantao Niu
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China
| | - Junfang Xian
- Department of Radiology, Beijing Tongren Hospital, Capital Medical University, No. 1 Dongjiaomin lane, Dongcheng District, Beijing 100730, P.R. China.
| |
Collapse
|
10
|
Schicchi N, Fogante M, Palumbo P, Agliata G, Esposto Pirani P, Di Cesare E, Giovagnoni A. The sub-millisievert era in CTCA: the technical basis of the new radiation dose approach. LA RADIOLOGIA MEDICA 2020; 125:1024-1039. [PMID: 32930945 DOI: 10.1007/s11547-020-01280-1] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 09/03/2020] [Indexed: 12/12/2022]
Abstract
Computed tomography coronary angiography (CTCA) has become a cornerstone in the diagnostic process of the heart disease. Although the cardiac imaging with interventional procedures is responsible for approximately 40% of the cumulative effective dose in medical imaging, a relevant radiation dose reduction over the last decade was obtained, with the beginning of the sub-mSv era in CTCA. The main technical basis to obtain a radiation dose reduction in CTCA is the use of a low tube voltage, the adoption of a prospective electrocardiogram-triggering spiral protocol and the application of the tube current modulation with the iterative reconstruction technique. Nevertheless, CTCA examinations are characterized by a wide range of radiation doses between different radiology departments. Moreover, the dose exposure in CTCA is extremely important because the benefit-risk calculus in comparison with other modalities also depends on it. Finally, because anatomical evaluation not adequately predicts the hemodynamic relevance of coronary stenosis, a low radiation dose in routine CTCA would allow the greatest use of the myocardial CT perfusion, fractional flow reserve-CT, dual-energy CT and artificial intelligence, to shift focus from morphological assessment to a comprehensive morphological and functional evaluation of the stenosis. Therefore, the aim of this work is to summarize the correct use of the technical basis in order that CTCA becomes an established examination for assessment of the coronary artery disease with low radiation dose.
Collapse
Affiliation(s)
- Nicolò Schicchi
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Marco Fogante
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy.
| | - Pierpaolo Palumbo
- Radiology Department, Azienda Ospedaliero Universitaria "San Salvatore", 60126, L'Aquila, Italy
| | - Giacomo Agliata
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Paolo Esposto Pirani
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| | - Ernesto Di Cesare
- Radiology Department, Azienda Ospedaliero Universitaria "San Salvatore", 60126, L'Aquila, Italy
| | - Andrea Giovagnoni
- Radiology Department, Azienda Ospedaliero Universitaria "Ospedali Riuniti", 60126, Ancona, Italy
| |
Collapse
|
11
|
Palumbo P, Cannizzaro E, Di Cesare A, Bruno F, Schicchi N, Giovagnoni A, Splendiani A, Barile A, Masciocchi C, Di Cesare E. Cardiac magnetic resonance in arrhythmogenic cardiomyopathies. Radiol Med 2020; 125:1087-1101. [PMID: 32978708 DOI: 10.1007/s11547-020-01289-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 09/08/2020] [Indexed: 12/13/2022]
Abstract
Over the past few years, the approach to the 'arrhythmic patient' has profoundly changed. An early clinical presentation of arrhythmia is often accompanied by non-specific symptoms and followed by inconclusive electrocardiographic findings. In this scenario, cardiac magnetic resonance (CMR) has been established as a clinical tool of fundamental importance for a correct prognostic stratification of the arrhythmic patient. This technique provides a high-spatial-resolution tomographic evaluation of the heart, which allows studying accurately the ventricular volumes, identifying even segmental kinetic anomalies and properly detecting diffuse or focal tissue alterations through an excellent tissue characterization, while depicting different patterns of fibrosis distribution, myocardial edema or fatty substitution. Through these capabilities, CMR has a pivotal role for the adequate management of the arrhythmic patient, allowing the identification of those phenotypic manifestations characteristic of structural heart diseases. Therefore, CMR provides valuable information to reclassify the patient within the wide spectrum of potentially arrhythmogenic heart diseases, the definition of which remains the major determinants for both an adequate treatment and a poor prognosis. The purpose of this review study was to focus on the role of CMR in the evaluation of the main cardiac clinical entities associated with arrhythmogenic phenomena and to present a brief debate on the main pathophysiological mechanisms involved in the arrhythmogenesis process.
Collapse
Affiliation(s)
- Pierpaolo Palumbo
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, AQ, Italy.
| | | | - Annamaria Di Cesare
- Department of Morphology, Surgery and Experimental Medicine, University of Ferrara, Ferrara, Italy
| | - Federico Bruno
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, AQ, Italy
| | - Nicolò Schicchi
- Department of Radiology, Azienda Ospedaliero-Universitaria, Ospedali Riuniti Di Ancona, Ancona, Italy
| | - Andrea Giovagnoni
- Department of Radiology, Azienda Ospedaliero-Universitaria, Ospedali Riuniti Di Ancona, Ancona, Italy
| | - Alessandra Splendiani
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, AQ, Italy
| | - Antonio Barile
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, AQ, Italy
| | - Carlo Masciocchi
- Department of Biotechnological and Applied Clinical Sciences, University of L'Aquila, Via Vetoio 1, 67100, L'Aquila, AQ, Italy
| | - Ernesto Di Cesare
- Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| |
Collapse
|
12
|
Coronary computed tomography angiography using model-based iterative reconstruction algorithms in the detection of significant coronary stenosis: how the plaque type influences the diagnostic performance. Pol J Radiol 2019; 84:e522-e529. [PMID: 32082450 PMCID: PMC7016499 DOI: 10.5114/pjr.2019.91259] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 11/04/2019] [Indexed: 01/14/2023] Open
Abstract
Purpose To evaluate the ability of coronary computed tomography angiography (CCTA) with model-based iterative reconstruction (MBIR) algorithm in detecting significant coronary artery stenosis compared with invasive coronary angiography (ICA). Material and methods We retrospectively identified 55 patients who underwent CCTA using the MBIR algorithm with evidence of at least one significant stenosis (≥ 50%) and an ICA within three months. Patients were stratified based on calcium score; stenoses were classified by type and by coronary segment involved. Dose-length-product was compared with the literature data obtained with previous reconstruction algorithms. Coronary artery stenosis was estimated on ICAs based on a qualitative method. Results CCTA data were confirmed by ICA in 89% of subjects, and in 73% and 94% of patients with CS < 400 and ≥ 400, respectively. ICA confirmed 81% of calcific stenoses, 91% of mixed, and 67% of soft plaques. Both the dose exposure of patients with prospective acquisition (34) and the exposure of the whole population were significantly lower than the standard of reference (p < 0.001 and p = 0.007). Conclusions CCTA with MBIR is valuable in detecting significant coronary artery stenosis with a solid reduction of radiation dose. Diagnostic performance was influenced by plaque composition, being lower compared with ICA for patients with lower CAC score and soft plaques; the visualisation of an intraluminal hypodensity could cause false positives, particularly in D1 and MO segments.
Collapse
|