1
|
Park HJ, Choi H, Ryu RR. Double low protocol in pediatric abdominal CT for evaluating right lower quadrant pain. Jpn J Radiol 2025:10.1007/s11604-025-01766-w. [PMID: 40156737 DOI: 10.1007/s11604-025-01766-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2024] [Accepted: 02/27/2025] [Indexed: 04/01/2025]
Abstract
PURPOSE In pediatric patients, minimizing radiation and contrast media exposure without compromising diagnostic accuracy is paramount. Double low protocol, which utilizes a low dose contrast concentration and low tube voltage, could be a safer alternative. We compare diagnostic efficacy of double low protocol (Group A, 240 mgI/ml + 80 kVp) with conventional protocol (Group B, 350 mgI/ml + 120 kVp) in pediatric patients (< 10 years) presenting with abdominal pain and suspected acute appendicitis. MATERIALS AND METHODS This retrospective study included 121 pediatric patients who underwent enhanced abdominal CT between January 2019 and February 2023: 62 with Group A and 59 with Group B. We compared radiation dose, iodine load, and quantitative image quality parameters. Two radiologists independently assessed diagnostic image quality on a 5-point scale, visualization of the appendix, and diagnostic performance for acute appendicitis and its complications. RESULTS There were no significant differences in mean age (7.6 ± 2.0 vs. 7.6 ± 2.1, p = 0.956), body weight (31.4 ± 11.2 kg vs. 31.7 ± 11.4 kg, p = 0.972), and contrast media volume used (59.3 ± 21.0 ml vs. 65.0 ± 20.0 ml, p = 135) between the two groups. However, effective dose and iodine load used were significantly lower in Group A compared to Group B (2.7 ± 1.1 mSv vs. 4.3 ± 1.5 mSv and vs. 12.7 ± 4.6gI vs.18.6 ± 6.7gI, all p < 0.001). Although diagnostic image quality, noise and signal-to-noise ratio were significantly lower in Group A, visualization of the appendix (p = 0.853) and diagnostic accuracy for appendicitis were comparable between the two groups (98.4% vs. 94.9%, p = 0.284). DISCUSSION The double low protocol offers an effective alternative for evaluating pediatric patients requiring enhanced abdomen CT, achieving comparable diagnostic performance while significantly reducing radiation dose. We believe that our findings support safer CT acquisition practices for pediatric patients requiring enhanced CT imaging.
Collapse
Affiliation(s)
- Hyun Jeong Park
- Department of Radiology, Chung-Ang University Hospitall, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
| | - Hyewon Choi
- Department of Radiology, Chung-Ang University Hospitall, Chung-Ang University College of Medicine, Seoul, Republic of Korea
| | - Rae Rim Ryu
- Department of Radiology, Chung-Ang University Hospitall, Chung-Ang University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
2
|
Sayed IS, Mohd Yusof MI. Techniques and Strategies to Minimize Radiation Exposure in Pediatric Computed Tomography (CT) Abdominal Examinations: A Review. Cureus 2024; 16:e67494. [PMID: 39310635 PMCID: PMC11416189 DOI: 10.7759/cureus.67494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/22/2024] [Indexed: 09/25/2024] Open
Abstract
As children are more vulnerable to radiation-induced cancers and have longer life expectancies, it is essential to implement strict radiation protection measures in pediatric imaging. This study aimed to review radiation dose-minimizing measures in pediatric abdominal computed tomography (CT) examinations. A systematic search across various databases, including Web of Science, PubMed, SpringerLink, ScienceDirect, and Google Scholar, yielded a total of 7,314 articles. The search used keywords that aligned with the objectives of the study. This study included 77 publications after applying the criteria for inclusion and exclusion. We carefully reviewed these selected articles for compliance with the inclusion criteria and excluded them if they did not meet the specified criteria. Only 12 articles fulfilled the strict criteria. An in-depth review of 12 selected articles demonstrated the radiation dose reduction techniques and strategies, which include prefiltering and post-processing algorithms, careful adjustment of exposure parameters such as tube voltage (kVp) and current (mAs), and the establishment of diagnostic reference levels (DRL). Reduction of radiation exposure in pediatric CT imaging demands multifaceted approaches. To reduce the ionizing radiation dose while still obtaining high-quality diagnostic images, healthcare practitioners should adhere to DRL, adjust exposure factors, implement prefiltration, employ AI, and use post-processing algorithms.
Collapse
Affiliation(s)
- Inayatullah Shah Sayed
- Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Kuantan, MYS
| | - Muhammad Irfan Mohd Yusof
- Department of Diagnostic Imaging and Radiotherapy, Kulliyyah of Allied Health Sciences, International Islamic University Malaysia, Kuantan, MYS
| |
Collapse
|
3
|
Ippolito D, Porta M, Maino C, Riva L, Ragusi M, Giandola T, Franco PN, Cangiotti C, Gandola D, De Vito A, Talei Franzesi C, Corso R. Feasibility of Low-Dose and Low-Contrast Media Volume Approach in Computed Tomography Cardiovascular Imaging Reconstructed with Model-Based Algorithm. Tomography 2024; 10:286-298. [PMID: 38393291 PMCID: PMC10891780 DOI: 10.3390/tomography10020023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/02/2024] [Accepted: 02/13/2024] [Indexed: 02/25/2024] Open
Abstract
Aim: To evaluate the dose reduction and image quality of low-dose, low-contrast media volume in computed tomography (CT) examinations reconstructed with the model-based iterative reconstruction (MBIR) algorithm in comparison with the hybrid iterative (HIR) one. Methods: We prospectively enrolled a total of 401 patients referred for cardiovascular CT, evaluated with a 256-MDCT scan with a low kVp (80 kVp) reconstructed with an MBIR (study group) or a standard HIR protocol (100 kVp-control group) after injection of a fixed dose of contrast medium volume. Vessel contrast enhancement and image noise were measured by placing the region of interest (ROI) in the left ventricle, ascending aorta; left, right and circumflex coronary arteries; main, right and left pulmonary arteries; aortic arch; and abdominal aorta. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed. Subjective image quality obtained by consensus was assessed by using a 4-point Likert scale. Radiation dose exposure was recorded. Results: HU values of the proximal tract of all coronary arteries; main, right and left pulmonary arteries; and of the aorta were significantly higher in the study group than in the control group (p < 0.05), while the noise was significantly lower (p < 0.05). SNR and CNR values in all anatomic districts were significantly higher in the study group (p < 0.05). MBIR subjective image quality was significantly higher than HIR in CCTA and CTPA protocols (p < 0.05). Radiation dose was significantly lower in the study group (p < 0.05). Conclusions: The MBIR algorithm combined with low-kVp can help reduce radiation dose exposure, reduce noise, and increase objective and subjective image quality.
Collapse
Affiliation(s)
- Davide Ippolito
- Departement of Medicine and Surgery, University of Milano-Bicocca, Piazza OMS 1, 20100 Milano, Italy;
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Marco Porta
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Cesare Maino
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Luca Riva
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Maria Ragusi
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Teresa Giandola
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Paolo Niccolò Franco
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Cecilia Cangiotti
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Davide Gandola
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Andrea De Vito
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Cammillo Talei Franzesi
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| | - Rocco Corso
- Department of Diagnostic Radiology, Fondazione IRCCS Fondazione San Gerardo dei Tintori, Via Pergolesi 33, 20900 Monza, Italy; (M.P.); (L.R.); (M.R.); (T.G.); (P.N.F.); (C.C.); (D.G.); (A.D.V.); (C.T.F.); (R.C.)
| |
Collapse
|
4
|
Guido G, Polici M, Nacci I, Bozzi F, De Santis D, Ubaldi N, Polidori T, Zerunian M, Bracci B, Laghi A, Caruso D. Iterative Reconstruction: State-of-the-Art and Future Perspectives. J Comput Assist Tomogr 2023; 47:244-254. [PMID: 36728734 DOI: 10.1097/rct.0000000000001401] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
ABSTRACT Image reconstruction processing in computed tomography (CT) has evolved tremendously since its creation, succeeding at optimizing radiation dose while maintaining adequate image quality. Computed tomography vendors have developed and implemented various technical advances, such as automatic noise reduction filters, automatic exposure control, and refined imaging reconstruction algorithms.Focusing on imaging reconstruction, filtered back-projection has represented the standard reconstruction algorithm for over 3 decades, obtaining adequate image quality at standard radiation dose exposures. To overcome filtered back-projection reconstruction flaws in low-dose CT data sets, advanced iterative reconstruction algorithms consisting of either backward projection or both backward and forward projections have been developed, with the goal to enable low-dose CT acquisitions with high image quality. Iterative reconstruction techniques play a key role in routine workflow implementation (eg, screening protocols, vascular and pediatric applications), in quantitative CT imaging applications, and in dose exposure limitation in oncologic patients.Therefore, this review aims to provide an overview of the technical principles and the main clinical application of iterative reconstruction algorithms, focusing on the strengths and weaknesses, in addition to integrating future perspectives in the new era of artificial intelligence.
Collapse
Affiliation(s)
- Gisella Guido
- From the Department of Surgical Medical Sciences and Translational Medicine, Sapienza University of Rome - Radiology Unit, Sant'Andrea University Hospital, Rome, Italy
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Russo GM, Russo A, Urraro F, Cioce F, Gallo L, Belfiore MP, Sangiovanni A, Napolitano S, Troiani T, Verolino P, Sica A, Brancaccio G, Briatico G, Nardone V, Reginelli A. Management of Non-Melanoma Skin Cancer: Radiologists Challenging and Risk Assessment. Diagnostics (Basel) 2023; 13:diagnostics13040793. [PMID: 36832281 PMCID: PMC9955870 DOI: 10.3390/diagnostics13040793] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/16/2023] [Accepted: 02/17/2023] [Indexed: 02/22/2023] Open
Abstract
Basal cell carcinoma, squamous cell carcinoma, and Merkel cell carcinoma are the three main types of nonmelanoma skin cancers and their rates of occurrence and mortality have been steadily rising over the past few decades. For radiologists, it is still difficult to treat patients with advanced nonmelanoma skin cancer. Nonmelanoma skin cancer patients would benefit greatly from an improved diagnostic imaging-based risk stratification and staging method that takes into account patient characteristics. The risk is especially elevated among those who previously received systemic treatment or phototherapy. Systemic treatments, including biologic therapies and methotrexate (MTX), are effective in managing immune-mediated diseases; however, they may increase susceptibility to NMSC due to immunosuppression or other factors. Risk stratification and staging tools are crucial in treatment planning and prognostic evaluation. PET/CT appears more sensitive and superior to CT and MRI for nodal and distant metastasis as well as in surveillance after surgery. The patient treatment response improved with advent and utilization of immunotherapy and different immune-specific criteria are established to standardized evaluation criteria of clinical trials but none of them have been utilized routinely with immunotherapy. The advent of immunotherapy has also arisen new critical issues for radiologists, such as atypical response pattern, pseudo-progression, as well as immune-related adverse events that require early identification to optimize and improve patient prognosis and management. It is important for radiologists to have knowledge of the radiologic features site of the tumor, clinical stage, histological subtype, and any high-risk features to assess immunotherapy treatment response and immune-related adverse events.
Collapse
Affiliation(s)
- Gaetano Maria Russo
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
- Correspondence:
| | - Anna Russo
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Fabrizio Urraro
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Fabrizio Cioce
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Luigi Gallo
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Maria Paola Belfiore
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Angelo Sangiovanni
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Stefania Napolitano
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Teresa Troiani
- Unit of Plastic Surgery, Multidisciplinary Department of Medical Surgical and Dental Specialties, University of Campania “Luigi Vanvitelli”, 80120 Naples, Italy
| | - Pasquale Verolino
- Unit of Plastic Surgery, Multidisciplinary Department of Medical Surgical and Dental Specialties, University of Campania “Luigi Vanvitelli”, 80120 Naples, Italy
| | - Antonello Sica
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Gabriella Brancaccio
- Unit of Dermatology, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Giulia Briatico
- Unit of Dermatology, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Valerio Nardone
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| | - Alfonso Reginelli
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80123 Naples, Italy
| |
Collapse
|
6
|
Granata V, Simonetti I, Fusco R, Setola SV, Izzo F, Scarpato L, Vanella V, Festino L, Simeone E, Ascierto PA, Petrillo A. Management of cutaneous melanoma: radiologists challenging and risk assessment. LA RADIOLOGIA MEDICA 2022; 127:899-911. [PMID: 35834109 DOI: 10.1007/s11547-022-01522-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Accepted: 06/27/2022] [Indexed: 02/07/2023]
Abstract
Melanoma patient remains a challenging for the radiologist, due to the difficulty related to the management of a patient more often in an advanced stage of the disease. It is necessary to determine a stratification of risk, optimizing the means, with diagnostic tools that should be optimized in relation to the type of patient, and improving knowledge. Staging and risk assessment procedures are determined by disease presentation at diagnosis. Melanoma staging is a critical tool to assist clinical decision-making and prognostic assessment. It is used for clinical trial design, eligibility, stratification, and analysis. The current standard for regional lymph nodes staging is represented by the sentinel lymph node excision biopsy procedure. For staging of distant metastases, PET-CT has the highest sensitivity and diagnostic odds ratio. Similar trend is observed during melanoma surveillance. The advent of immunotherapy, which has improved patient outcome, however, has determined new issues for radiologists, partly due to atypical response patterns, partly due to adverse reactions that must be identified as soon as possible for the correct management of the patient. The main objectives of the new ir-criteria are to standardize the assessment between different trials. However, these ir-criteria do not take into account all cases of atypical response patterns, as hyperprogression or dissociated responses. None of these criteria has actually been uniformly adopted in routine. The immune-related adverse events (irAEs) can involve various organs from head to toe. It is crucial for radiologists to know the imaging appearances of this condition, to exclude recurrent or progressive disease and for pneumonitis, since it could be potentially life-threatening toxicity, resulting in pneumonitis-related deaths in early phase trials, to allow a proper patient management.
Collapse
Affiliation(s)
- Vincenza Granata
- Radiology Division, "Istituto Nazionale Tumori - IRCCS - Fondazione G. Pascale, Naples, Italia", Via Mariano Semmola, Naples, Italy.
| | - Igino Simonetti
- Radiology Division, "Istituto Nazionale Tumori - IRCCS - Fondazione G. Pascale, Naples, Italia", Via Mariano Semmola, Naples, Italy
| | | | - Sergio Venanzio Setola
- Radiology Division, "Istituto Nazionale Tumori - IRCCS - Fondazione G. Pascale, Naples, Italia", Via Mariano Semmola, Naples, Italy
| | - Francesco Izzo
- Hepatobiliary Surgical Oncology Division, "Istituto Nazionale Tumori - IRCCS - Fondazione G. Pascale, Naples, Italia",, Via Mariano Semmola, Naples, Italy
| | - Luigi Scarpato
- Department of Skin Cancers, Cancer Immunotherapy and Development Therapeutics, Istituto Nazionale Tumori IRCCS Fondazione Pascale, Naples, Italy
| | - Vito Vanella
- Department of Skin Cancers, Cancer Immunotherapy and Development Therapeutics, Istituto Nazionale Tumori IRCCS Fondazione Pascale, Naples, Italy
| | - Lucia Festino
- Department of Skin Cancers, Cancer Immunotherapy and Development Therapeutics, Istituto Nazionale Tumori IRCCS Fondazione Pascale, Naples, Italy
| | - Ester Simeone
- Department of Skin Cancers, Cancer Immunotherapy and Development Therapeutics, Istituto Nazionale Tumori IRCCS Fondazione Pascale, Naples, Italy
| | - Paolo Antonio Ascierto
- Department of Skin Cancers, Cancer Immunotherapy and Development Therapeutics, Istituto Nazionale Tumori IRCCS Fondazione Pascale, Naples, Italy
| | - Antonella Petrillo
- Radiology Division, "Istituto Nazionale Tumori - IRCCS - Fondazione G. Pascale, Naples, Italia", Via Mariano Semmola, Naples, Italy
| |
Collapse
|
7
|
Granata V, Fusco R, Belli A, Danti G, Bicci E, Cutolo C, Petrillo A, Izzo F. Diffusion weighted imaging and diffusion kurtosis imaging in abdominal oncological setting: why and when. Infect Agent Cancer 2022; 17:25. [PMID: 35681237 PMCID: PMC9185934 DOI: 10.1186/s13027-022-00441-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 05/30/2022] [Indexed: 12/13/2022] Open
Abstract
This article provides an overview of diffusion kurtosis (DKI) imaging in abdominal oncology. DKI allows for more data on tissue structures than the conventional diffusion model (DWI). However, DKI requires high quality images at b-values greater than 1000 s/mm2 and high signal-to-noise ratio (SNR) that traditionally MRI systems are not able to acquire and therefore there are generally amplified anatomical distortions on the images due to less homogeneity of the field. Advances in both hardware and software on modern MRI scanners have currently enabled ultra-high b-value imaging and offered the ability to apply DKI to multiple extracranial sites. Previous studies have evaluated the ability of DKI to characterize and discriminate tumor grade compared to conventional DWI. Additionally, in several studies the DKI sequences used were based on planar echo (EPI) acquisition, which is susceptible to motion, metal and air artefacts and prone to low SNRs and distortions, leading to low quality images for some small lesions, which may affect the accuracy of the results. Another problem is the optimal b-value of DKI, which remains to be explored and not yet standardized, as well as the manual selection of the ROI, which could affect the accuracy of some parameters.
Collapse
Affiliation(s)
- Vincenza Granata
- Division of Radiology, "Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli", I-80131, Naples, Italy.
| | | | - Andrea Belli
- Division of Hepatobiliary Surgical Oncology, "Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli", I-80131, Naples, Italy
| | - Ginevra Danti
- Department of Radiology, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy.,Italian Society of Medical and Interventional Radiology, SIRM Foundation, Milan, Italy
| | - Eleonora Bicci
- Department of Radiology, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Carmen Cutolo
- Department of Medicine, Surgery and Dentistry, University of Salerno, Salerno, Italy
| | - Antonella Petrillo
- Division of Radiology, "Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli", I-80131, Naples, Italy
| | - Francesco Izzo
- Division of Hepatobiliary Surgical Oncology, "Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli", I-80131, Naples, Italy
| |
Collapse
|
8
|
Analysis of a monocentric computed tomography dosimetric database using a radiation dose index monitoring software: dose levels and alerts before and after the implementation of the adaptive statistical iterative reconstruction on CT images. Radiol Med 2022; 127:733-742. [PMID: 35579854 DOI: 10.1007/s11547-022-01481-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 03/08/2022] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To analyze dosimetric data of a single center by a radiation dose index monitoring software evaluating quantitatively the dose reduction obtained with the implementation of the adaptive statistical iterative reconstruction (ASIR) on Computed Tomography in terms of both the value of the dose length product (DLP) and the alerts provided by the dose tool. METHODS Dosimetric quantities were acquired using Qaelum DOSE tool (QAELUM NV, Leuven-Heverlee, Belgium). Dose data pertaining to CT examinations were performed using a General Electric Healthcare CT tomography with 64 detectors. CT dose data were collected over 4 years (January 1, 2017 to December 31, 2020) and included CT dose length product (DLP). Moreover, all CT examinations that triggered a high radiation dose (twice the median for that study description), termed alerts on Dose tool, were retrieved for the analysis. Two radiologists retrospectively assessed CT examinations in consensus for the images quality and for the causes of the alerts issued. A Chi-square test was used to assess whether there were any statistically significant differences among categorical variable while a Kruskal Wallis test was considered to assess differences statistically significant for continuous variables. RESULTS Differences statistically significant were found for the DLP median values between the dosimetric data recorded on 2017-2018 versus 2019-2020. The differences were linked to the implementation of ASIR technique at the end of 2018 on the CT scanner. The highest percentage of alerts was reported in the CT study group "COMPLETE ABDOMEN + CHEST + HEAD" (range from 1.26% to 2.14%). A reduction year for year was relieved linked to the CT protocol optimization with a difference statistically significant. The highest percentage of alerts was linked to wrong study label/wrong study protocol selection with a range from 29 to 40%. CONCLUSIONS Automated methods of radiation dose data collection allowed for detailed radiation dose analysis according to protocol and equipment over time. The use of CT ASIR technique could determine considerable reduction in radiation dose.
Collapse
|
9
|
The Role of Magnetic Resonance Enterography in Crohn’s Disease: A Review of Recent Literature. Diagnostics (Basel) 2022; 12:diagnostics12051236. [PMID: 35626391 PMCID: PMC9140029 DOI: 10.3390/diagnostics12051236] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 05/06/2022] [Accepted: 05/13/2022] [Indexed: 11/17/2022] Open
Abstract
Inflammatory bowel disease (IBD) is the term used to identify a form of chronic inflammation of the gastrointestinal tract that primarily contemplates two major entities: ulcerative colitis (UC) and Crohn’s disease (CD). The classic signs are abdominal pain and diarrhoea that correlate with the localization of gastro-enteric disease, although in this pathology extraintestinal symptoms may coexist. The diagnosis of CD relies on a synergistic combination of clinical, laboratory (stool and biochemical), cross-sectional imaging evaluation, as well as endoscopic and histologic assessments. The purpose of this paper is to prove the role of imaging in the diagnosis and follow-up of patients with CD with particular focus on recent innovations of magnetic resonance enterography (MRE) as a pivotal diagnostic tool, analysing the MRE study protocol and imaging features during the various phases of disease activity and its complications.
Collapse
|
10
|
Granata V, Fusco R, De Muzio F, Cutolo C, Setola SV, Simonetti I, Dell’Aversana F, Grassi F, Bruno F, Belli A, Patrone R, Pilone V, Petrillo A, Izzo F. Complications Risk Assessment and Imaging Findings of Thermal Ablation Treatment in Liver Cancers: What the Radiologist Should Expect. J Clin Med 2022; 11:2766. [PMID: 35628893 PMCID: PMC9147303 DOI: 10.3390/jcm11102766] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 05/10/2022] [Accepted: 05/12/2022] [Indexed: 02/04/2023] Open
Abstract
One of the major fields of application of ablation treatment is liver tumors. With respect to HCC, ablation treatments are considered as upfront treatments in patients with early-stage disease, while in colorectal liver metastases (CLM), they can be employed as an upfront treatment or in association with surgical resection. The main prognostic feature of ablation is the tumor size, since the goal of the treatment is the necrosis of all viable tumor tissue with an adequate tumor-free margin. Radiofrequency ablation (RFA) and microwave ablation (MWA) are the most employed ablation techniques. Ablation therapies in HCC and liver metastases have presented a challenge to radiologists, who need to assess response to determine complication-related treatment. Complications, defined as any unexpected variation from a procedural course, and adverse events, defined as any actual or potential injury related to the treatment, could occur either during the procedure or afterwards. To date, RFA and MWA have shown no statistically significant differences in mortality rates or major or minor complications. To reduce the rate of major complications, patient selection and risk assessment are essential. To determine the right cost-benefit ratio for the ablation method to be used, it is necessary to identify patients at high risk of infections, coagulation disorders and previous abdominal surgery interventions. Based on risk assessment, during the procedure as part of surveillance, the radiologists should pay attention to several complications, such as vascular, biliary, mechanical and infectious. Multiphase CT is an imaging tool chosen in emergency settings. The radiologist should report technical success, treatment efficacy, and complications. The complications should be assessed according to well-defined classification systems, and these complications should be categorized consistently according to severity and time of occurrence.
Collapse
Affiliation(s)
- Vincenza Granata
- Radiology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (S.V.S.); (I.S.); (A.P.)
| | - Roberta Fusco
- Medical Oncology Division, Igea SpA, 80013 Naples, Italy;
| | - Federica De Muzio
- Department of Medicine and Health Sciences V. Tiberio, University of Molise, 86100 Campobasso, Italy;
| | - Carmen Cutolo
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84084 Fisciano, Italy; (C.C.); (V.P.)
| | - Sergio Venanzio Setola
- Radiology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (S.V.S.); (I.S.); (A.P.)
| | - Igino Simonetti
- Radiology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (S.V.S.); (I.S.); (A.P.)
| | - Federica Dell’Aversana
- Division of Radiology, Università degli Studi della Campania Luigi Vanvitelli, 80138 Naples, Italy; (F.D.); (F.G.)
| | - Francesca Grassi
- Division of Radiology, Università degli Studi della Campania Luigi Vanvitelli, 80138 Naples, Italy; (F.D.); (F.G.)
| | - Federico Bruno
- Italian Society of Medical and Interventional Radiology (SIRM), SIRM Foundation, 20122 Milan, Italy;
- Department of Applied Clinical Sciences and Biotechnology, University of L’Aquila, 67100 L’Aquila, Italy
| | - Andrea Belli
- Hepatobiliary Surgical Oncology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (A.B.); (R.P.); (F.I.)
| | - Renato Patrone
- Hepatobiliary Surgical Oncology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (A.B.); (R.P.); (F.I.)
| | - Vincenzo Pilone
- Department of Medicine, Surgery and Dentistry, University of Salerno, 84084 Fisciano, Italy; (C.C.); (V.P.)
| | - Antonella Petrillo
- Radiology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (S.V.S.); (I.S.); (A.P.)
| | - Francesco Izzo
- Hepatobiliary Surgical Oncology Division, Istituto Nazionale Tumori—IRCCS—Fondazione G. Pascale, Via Mariano Semmola, 80131 Naples, Italy; (A.B.); (R.P.); (F.I.)
| |
Collapse
|
11
|
Complications after Thermal Ablation of Hepatocellular Carcinoma and Liver Metastases: Imaging Findings. Diagnostics (Basel) 2022; 12:diagnostics12051151. [PMID: 35626306 PMCID: PMC9139664 DOI: 10.3390/diagnostics12051151] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 04/26/2022] [Accepted: 05/03/2022] [Indexed: 01/25/2023] Open
Abstract
Tumour ablation is a strategy of treatment of hepatic tumours in patients with small hepatocellular carcinoma (HCC) (<3 cm) or in patients unfit for surgical resection. Moreover, tumor ablation can be used as an adjuvant therapy or may be used in association with resection in case of patients with poor functional liver disease. These types of treatment usually could be performed percutaneously under image guidance. The most clinically verified and used ablation modalities are Radiofrequency Ablation (RFA) and microwave ablation (MWA). However, despite both of them are considered minimally invasive techniques, they could be related to post-procedural complications. The International Working Group on Image-Guided Tumor and the Society of Interventional Radiology (SIR) identified major and minor post-ablative complications. Major complications, as vascular complications, occur in 2.2% to 3.1% of cases and include all the high risk pathological conditions which could increase the level of care or result in hospital admission or substantially prolonged hospital stay (SIR classifications C−E). Minor complications, as biliary complications, occur in 5% to 8.9% and include self-limiting conditions that are considered to be of low risk for the patient’s outcome. The purpose of this review is to summarise the main pathological ultrasound (US) and Computed Tomography (CT) findings, that may arise after ablative treatment. To simplify the analysis, the pathological pictures are divided according to the site of damage into vascular, biliary and extrahepatic complications.
Collapse
|
12
|
Sun J, Li H, Li H, Li M, Gao Y, Zhou Z, Peng Y. Application of deep learning image reconstruction algorithm to improve image quality in CT angiography of children with Takayasu arteritis. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2022; 30:177-184. [PMID: 34806646 DOI: 10.3233/xst-211033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
BACKGROUND The inflammatory indexes of children with Takayasu arteritis (TAK) usually tend to be normal immediately after treatment, therefore, CT angiography (CTA) has become an important method to evaluate the status of TAK and sometime is even more sensitive than laboratory test results. OBJECTIVE To evaluate image quality improvement in CTA of children diagnosed with TAK using a deep learning image reconstruction (DLIR) in comparison to other image reconstruction algorithms. METHODS hirty-two TAK patients (9.14±4.51 years old) underwent neck, chest and abdominal CTA using 100 kVp were enrolled. Images were reconstructed at 0.625 mm slice thickness using Filtered Back-Projection (FBP), 50%adaptive statistical iterative reconstruction-V (ASIR-V), 100%ASIR-V and DLIR with high setting (DLIR-H). CT number and standard deviation (SD) of the descending aorta and back muscle were measured and contrast-to-noise ratio (CNR) for aorta was calculated. The vessel visualization, overall image noise and diagnostic confidence were evaluated using a 5-point scale (5, excellent; 3, acceptable) by 2 observers. RESULTS There was no significant difference in CT number across images reconstructed using different algorithms. Image noise values (in HU) were 31.36±6.01, 24.96±4.69, 18.46±3.91 and 15.58±3.65, and CNR values for aorta were 11.93±2.12, 15.66±2.37, 22.54±3.34 and 24.02±4.55 using FBP, 50%ASIR-V, 100%ASIR-V and DLIR-H, respectively. The 100%ASIR-V and DLIR-H images had similar noise and CNR (all P > 0.05), and both had lower noise and higher CNR than FBP and 50%ASIR-V images (all P < 0.05). The subjective evaluation suggested that all images were diagnostic for large arteries, however, only 50%ASIR-V and DLIR-H met the diagnostic requirement for small arteries (3.03±0.18 and 3.53±0.51). CONCLUSION DLIR-H improves CTA image quality and diagnostic confidence for TAK patients compared with 50%ASIR-V, and best balances image noise and spatial resolution compared with 100%ASIR-V.
Collapse
Affiliation(s)
- Jihang Sun
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Haoyan Li
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Haiyun Li
- School of Biomedical Engineering, Capital Medical University, Fengtai District, Beijing, China
| | - Michelle Li
- Department of Human Biology, Stanford University, Stanford, CA, USA
| | - Yingzi Gao
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Zuofu Zhou
- Department of Radiology, Fujian Provincial Maternity and Children's Hospital, Affiliated Hospital of Fujian Medical University, Gulou District, Fujian, China
| | - Yun Peng
- Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| |
Collapse
|
13
|
Structured Reporting of Computed Tomography and Magnetic Resonance in the Staging of Pancreatic Adenocarcinoma: A Delphi Consensus Proposal. Diagnostics (Basel) 2021; 11:diagnostics11112033. [PMID: 34829384 PMCID: PMC8621603 DOI: 10.3390/diagnostics11112033] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 10/31/2021] [Accepted: 11/01/2021] [Indexed: 12/12/2022] Open
Abstract
Background: Structured reporting (SR) in radiology has been recognized recently by major scientific societies. This study aims to build structured computed tomography (CT) and magnetic resonance (MR)-based reports in pancreatic adenocarcinoma during the staging phase in order to improve communication between the radiologist and members of multidisciplinary teams. Materials and Methods: A panel of expert radiologists, members of the Italian Society of Medical and Interventional Radiology, was established. A modified Delphi process was used to develop the CT-SR and MRI-SR, assessing a level of agreement for all report sections. Cronbach’s alpha (Cα) correlation coefficient was used to assess internal consistency for each section and to measure quality analysis according to the average inter-item correlation. Results: The final CT-SR version was built by including n = 16 items in the “Patient Clinical Data” section, n = 11 items in the “Clinical Evaluation” section, n = 7 items in the “Imaging Protocol” section, and n = 18 items in the “Report” section. Overall, 52 items were included in the final version of the CT-SR. The final MRI-SR version was built by including n = 16 items in the “Patient Clinical Data” section, n = 11 items in the “Clinical Evaluation” section, n = 8 items in the “Imaging Protocol” section, and n = 14 items in the “Report” section. Overall, 49 items were included in the final version of the MRI-SR. In the first round for CT-SR, all sections received more than a good rating. The overall mean score of the experts was 4.85. The Cα correlation coefficient was 0.85. In the second round, the overall mean score of the experts was 4.87, and the Cα correlation coefficient was 0.94. In the first round, for MRI-SR, all sections received more than a good rating. The overall mean score of the experts was 4.73. The Cα correlation coefficient was 0.82. In the second round, the overall mean score of the experts was 4.91, and the Cα correlation coefficient was 0.93. Conclusions: The CT-SR and MRI-SR are based on a multi-round consensus-building Delphi exercise derived from the multidisciplinary agreement of expert radiologists in order to obtain more appropriate communication tools for referring physicians.
Collapse
|
14
|
Sun J, Li H, Gao J, Li J, Li M, Zhou Z, Peng Y. Performance evaluation of a deep learning image reconstruction (DLIR) algorithm in "double low" chest CTA in children: a feasibility study. Radiol Med 2021; 126:1181-1188. [PMID: 34132926 DOI: 10.1007/s11547-021-01384-2] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Accepted: 06/08/2021] [Indexed: 01/06/2023]
Abstract
BACKGROUND Chest CT angiography (CTA) is a convenient clinical examination for children with an increasing need to reduce both radiation and contrast medium doses. Iterative Reconstruction algorithms are often used to reduce image noise but encounter limitations under low radiation dose and conventional 100 kVp tube voltage may not provide adequate enhancement under low contrast dose. PURPOSE To evaluate the performance of a deep learning image reconstruction (DLIR) algorithm in conjunction with lower tube voltage in chest CTA in children under reduced radiation and contrast medium (CM) dose. MATERIALS AND METHODS 46 Children (age 5.9 ± 4.2 years) in the study group underwent chest CTA with 70 kVp and CM dose of 0.8-1.2 ml/kg. Images were reconstructed at 0.625 mm using a high setting DLIR (DLIR-H). The control group consisted of 46 age-matching children scanned with 100 kVp, CM dose of 1.3-1.8 ml/kg and images reconstructed with 50% and 100% adaptive statistical iterative reconstruction-V. Two radiologists evaluated images subjectively for overall image noise, vessel contrast and vessel margin clarity separately on a 5-point scale (5, excellent and 1, not acceptable). CT value and image noise of aorta and erector spinae muscle were measured. RESULTS Compared to the control group, the study group reduced the dose-length-product by 11.2% (p = 0.01) and CM dose by 24% (p < 0.001), improved the enhancement in aorta (416.5 ± 113.1HU vs. 342.0 ± 57.6HU, p < 0.001) and reduced noise (15.1 ± 3.5HU vs. 18.6 ± 4.4HU, p < 0.001). The DLIR-H images provided acceptable scores on all 3 aspects of the qualitative evaluation. CONCLUSION "Double low" chest CTA in children using 70 kVp and DLIR provides high image quality with reduced noise and improved vessel enhancement for diagnosis while further reduces radiation and CM dose.
Collapse
Affiliation(s)
- Jihang Sun
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing, 100045, China
| | - Haoyan Li
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing, 100045, China
| | - Jun Gao
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing, 100045, China
| | | | | | - Zuofu Zhou
- Department of Radiology, Fujian Provincial Maternity and Children's Hospital, Affiliated Hospital of Fujian Medical University, No. 18 Daoshan Road, Gulou District, Fujian, 350000, China
| | - Yun Peng
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, No. 56, Nanlishi Road, Xicheng District, Beijing, 100045, China.
| |
Collapse
|
15
|
Zhang X, Chen J, Yu N, Ren Z, Tian Q, Tian X, Jia Y, He T, Guo C. Reducing contrast medium dose with low photon energy images in renal dual-energy spectral CT angiography and adaptive statistical iterative reconstruction (ASIR). Br J Radiol 2021; 94:20200974. [PMID: 33684310 DOI: 10.1259/bjr.20200974] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE To evaluate the value of using low energy (keV) images in renal dual-energy spectral CT angiography (CTA) and adaptive statistical iterative reconstruction (ASIR) to reduce contrast medium dose. METHODS 40 patients with renal CTA on a Discovery CT750HD were randomly divided into two groups: 20 cases (Group A) with 600 mgI kg-1 and 20 cases (Group B) with 300 mgI kg-1. The scan protocol for both groups was: dual-energy mode with mA selection for noise index of 10 HU, pitch 1.375:1, rotating speed 0.6 s/r. Images were reconstructed at 0.625 mm thickness with 40%ASIR, Group A used the conventional 70keV monochromatic images, and Group B used monochromatic images from 40 to 70 keV at 5 keV interval for analysis. The CT values and standard deviation (SD) values of the renal artery and erector spine in the plain and arterial phases were measured with the erector spine SD value representing image noise. The enhancement degree of the renal artery (ΔCT = CT(arterial) -CT(plain)), signal-to-noise ratio (SNR=CTrenal-artery/SDrenal-artery) and contrast-to-noise ratio (CNR=(CTrenal-artery-CTerector spine)/SDerector-spine) were calculated. The single factor analysis of variance was used to analyze the difference of ΔCT, SNR and CNR among image groups with p < 0.05 being statistically significant. The subjective image scores of the groups were assessed blindly by two experienced physicians using a 5-point system and the score consistency was compared by the κ test. RESULTS Contrast medium dose in the 300 mgI kg-1 group was reduced by 50% compared with the 600 mgI kg-1 group, while radiation dose was similar between the two groups. The subjective scores were 4.00 ± 0.65, 4.50 ± 0.60 and 3.70 ± 0.80 for images at 70 keV (600 mgI kg-1 group), 40 keV (300 mgI kg-1 group) and 45 keV (300 mgI kg-1 group), respectively with good consistency between the two reviewers (p > 0.05). The 40 keV images in the 300 mgI kg-1 group had similar ΔCT (469.77 ± 86.95 HU vs 398.54 ± 73.68 HU) and CNR (15.52 ± 3.32 vs 18.78 ± 6.71) values as the 70 keV images in the 600 mgI kg-1) group but higher SNR values (30.19 ± 4.41 vs 16.91 ± 11.12, p < 0,05). CONCLUSION Contrast dose may be reduced by 50% while maintaining image quality by using lower energy images combined with ASIR in renal dual-energy CTA. ADVANCES IN KNOWLEDGE Combined with ASIR and energy spectrum, can reduce the amount of contrast dose in renal CTA.
Collapse
Affiliation(s)
- Xirong Zhang
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Jing Chen
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Nan Yu
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Zhanli Ren
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Qian Tian
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Xin Tian
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Yongjun Jia
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Taiping He
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| | - Changyi Guo
- Department of Medical Techniques, Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China.,Department of Radiology, The Second Affiliated Hospital of Shaanxi University of Chinese medicine, Xianyang, China
| |
Collapse
|