1
|
Shi LQ, Sun J, Yuan L, Wang XW, Li W, Cheng CY, Guo WD, Hong Y. Diagnostic performance of renal cortical elasticity by supersonic shear wave imaging in pediatric glomerular disease. Eur J Radiol 2023; 168:111113. [PMID: 37820521 DOI: 10.1016/j.ejrad.2023.111113] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 09/22/2023] [Accepted: 09/24/2023] [Indexed: 10/13/2023]
Abstract
PURPOSE To explore the diagnostic performance of renal cortical elasticity expressed by Young's modulus (YM) using the supersonic shear wave imaging (SSI) technique in pediatric glomerular disease. MATERIALS AND METHODS Seventy-one children with glomerular disease confirmed by renal biopsy and sixty healthy volunteers were enrolled in this study. Conventional and SSI ultrasound examinations were performed in all individuals for both kidneys. We measured renal length, renal width, renal thickness, parenchyma thickness, interlobar arterial resistive index (RI) and the YM of the middle and lower pole. RESULTS Regardless of which pole and which side of the kidney, the YM in the disease group was significantly higher than that in the control group (P < 0.001). The YM of the middle pole in the left kidney demonstrated the largest AUC (0.936, P < 0.001), and the corresponding cut-off value was 15.48 kPa with a sensitivity of 87.3% and a specificity of 86.7%. There was no significant difference in the YM among different pathological types of pediatric glomerular disease in the disease group, and the same in different grades of patients with Immunoglobulin A (IgA) nephropathy by Lee classification and the Oxford Classification as well as Henoch-Schonlein purpura nephritis (HSPN) by International Study of Kidney Disease in Children (ISKDC) classification (P > 0.05). We found positive but weak correlations between the YM and renal length (r = 0.299, P = 0.001), renal width (r = 0.408, P < 0.001), renal thickness (r = 0.299, P = 0.001), and parenchyma thickness (r = 0.212, P = 0.015), whereas the YM had no significant correlations with age, sex, BMI, interlobar arterial RI, and laboratory findings (P > 0.05). CONCLUSIONS SSI technology is a non-invasive and feasible method for the diagnosis of pediatric glomerular disease. However, SSI did not show good performance in distinguishing different pathological types and disease grades in our study.
Collapse
Affiliation(s)
- Li-Qiong Shi
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| | - Jie Sun
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| | - Li Yuan
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China.
| | - Xiao-Wen Wang
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| | - Wei Li
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| | - Chun-Yue Cheng
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| | - Wu-Dan Guo
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| | - Yue Hong
- Department of Ultrasound Imaging, Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science & Technology, No. 100 Xianggang Road, Wuhan City, Hubei 430016, China
| |
Collapse
|
2
|
Yao S, Cai Y, Hu S, Liu X, Gao X, Li G, Wang H, Yu H. The value of shear wave elasticity and shear wave dispersion imaging to evaluate the viscoelasticity of renal parenchyma in children with glomerular diseases. BMC Nephrol 2023; 24:306. [PMID: 37858094 PMCID: PMC10588180 DOI: 10.1186/s12882-023-03357-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 09/30/2023] [Indexed: 10/21/2023] Open
Abstract
BACKGROUND To study the value of shear wave elasticity and shear wave dispersion imaging to evaluate the viscoelasticity of renal parenchyma in children with glomerular diseases. METHODS Forty-three children with glomerular diseases were prospectively evaluated by shear wave elasticity (SWE) and shear wave dispersion imaging (SWD); 43 healthy volunteers served as the control group. The shear wave velocities (SWV) and the dispersion slopes were measured at the upper, middle, and lower poles of both kidneys. The analysis of mean SWV and mean dispersion slope in control and patient groups was used to further evaluate the value of SWE and SWD in the viscoelasticity of renal parenchyma in children with glomerular disease. RESULTS The mean SWV in children with glomerular disease was higher than that in the healthy control group (1.61 ± 0.09 m/s vs. 1.43 ± 0.07 m/s, p < 0.001). Compared with healthy group, the mean dispersion slope in children with glomerular disease was significantly increased (13.5 ± 1.39 (m/s)/kHz vs. 12.4 ± 1.40 (m/s)/kHz, p < 0.001). Correlation analysis showed absence of correlation between the SWV and dispersion slope of occult blood, serum creatinine, 24-h urine protein, blood albumin, BMI and ROI box depth of children with glomerular disease. CONCLUSIONS The present study shows that it is feasible to use SWE and SWD to evaluate the difference of viscoelasticity of the renal parenchyma between healthy children and those with glomerular disease.
Collapse
Affiliation(s)
- Shixiang Yao
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No.9, Jinsui Road, Guangzhou, Guangdong, China
| | - Yingying Cai
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No.9, Jinsui Road, Guangzhou, Guangdong, China
| | - Shanshan Hu
- The Sixth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, Guangdong, China
| | - Xiao Liu
- Department of Ultrasonography, Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen, Guangdong, China
| | - Xia Gao
- Nephrology department, Guangdong Provincial Clinical Research Center for Child Health, Guangzhou Women and Children's medical center, Guangzhou city, China
| | - Guanyu Li
- Nephrology department, Guangdong Provincial Clinical Research Center for Child Health, Guangzhou Women and Children's medical center, Guangzhou city, China
| | - Hongying Wang
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No.9, Jinsui Road, Guangzhou, Guangdong, China
| | - Hongkui Yu
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, No.9, Jinsui Road, Guangzhou, Guangdong, China.
| |
Collapse
|
3
|
Ozmen Z, Kasap T, Aktas F, Ozmen ZC. Shear wave elastography evaluation of kidneys in children with familial mediterranean fever. Niger J Clin Pract 2023; 26:957-962. [PMID: 37635580 DOI: 10.4103/njcp.njcp_698_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2023]
Abstract
Background and Aim Familial Mediterranean fever (FMF) is an autosomal recessive disorder. Typical clinical manifestations are self-limiting attacks of recurrent fever, abdominal pain, arthralgia, and chest pain due to aseptic polyserositis. Renal involvement is common in FMF patients. Shear wave elastography (SWE) is a noninvasive method that provides the measurement of tissue stiffness. In this study, we aimed to show that SWE can be used as an adjunctive method for evaluating renal involvement in children with FMF. Materials and Methods Our study group consists of 79 pediatric FMF patients and 79 control individuals. The study was planned prospectively. The variables, such as age, height, weight, and body mass index (BMI) of the patient and control groups, were kept in a similar way in order not to be affected by the differences. The right and left kidney sizes, parenchymal thicknesses, and SWE values in both groups were compared. The parenchymal stiffness degrees of the kidneys were quantified by shear modulus values in kilopascals. Results In our study, no statistically significant difference was found between the control and patient groups in terms of the right and left kidney longitudinal dimensions, transverse dimensions, and parenchymal thicknesses. When the kidneys were evaluated in terms of the right and left kidney stiffness values, the stiffness values in the patient group were significantly higher in both kidneys compared with those in the control group (P < 0.001). Conclusions SWE can be a noninvasive quantitative imaging method that can be used to evaluate kidney involvement by detecting changes in kidney stiffness in children with FMF.
Collapse
Affiliation(s)
- Z Ozmen
- Department of Radiology, School of Medicine, Gaziosmanpasa University, Tokat, Turkey
| | - T Kasap
- Department of Pediatric Diseases, School of Medicine, Gaziosmanpasa University, Tokat, Turkey
| | - F Aktas
- Department of Radiology, School of Medicine, Gaziosmanpasa University, Tokat, Turkey
| | - Z C Ozmen
- Department of Biochemistry, School of Medicine, Gaziosmanpasa University, Tokat, Turkey
| |
Collapse
|
4
|
Yao S, Liu X, Wang H, Yu H. Evaluation of renal parenchyma stiffness in children with nephropathy by shear wave elastography: A systematic review and meta-analysis. Int J Urol 2023; 30:28-35. [PMID: 36125940 DOI: 10.1111/iju.15054] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 09/07/2022] [Indexed: 01/31/2023]
Abstract
BACKGROUND The role of shear wave elastography (SWE) in assessing renal parenchymal stiffness in children with nephropathy is obscure. This systematic review and meta-analysis investigated this issue. MATERIALS AND METHODS PubMed, Embase, Web of Science, and the Cochrane Library databases were searched for studies evaluating renal parenchyma stiffness in children with nephropathy by SWE from inception to October 2021. The search was not limited by language. Two investigators independently screened the literature and extracted data. Any discrepancies were resolved via discussion with the senior professor. Study quality was assessed by the Newcastle-Ottawa Scale and the standardized mean difference of shear wave velocity (SWV) for the evaluation of renal parenchyma stiffness was determined. RESULTS Eight studies involving a total of 496 children with nephropathy and 353 healthy children were selected. Eight studies used SWV as parameters of renal parenchyma stiffness. The SWV was not significantly different in children with renal lesion than in those without renal lesion, with a standardized mean difference of 0.49 (95% confidence level, -0.40 to 1.39, p = 0.28). There was a high heterogeneity between studies. CONCLUSION Although there was significant difference in SWE of renal parenchyma between controls and patients in each study we included, statistical differences were not seen after results of all research were amalgamated due to different diseases with different pathomechanisms. SWE could be used to evaluate renal parenchymal stiffness in children with kidney disease after more well-designed and high-quality studies with a large sample size will be performed in the future.
Collapse
Affiliation(s)
- Shixiang Yao
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Xiao Liu
- Department of Ultrasonography, Shenzhen Hospital of Guangzhou University of Chinese Medicine, Shenzhen, Guangdong, China
| | - Hongying Wang
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, China
| | - Hongkui Yu
- Department of Ultrasonography, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, China
| |
Collapse
|
5
|
Yoǧurtçuoǧlu B, Damar Ç. Renal elastography measurements in children with acute glomerulonephritis. Ultrasonography 2021; 40:575-583. [PMID: 33906284 PMCID: PMC8446499 DOI: 10.14366/usg.20173] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 02/10/2021] [Accepted: 03/04/2021] [Indexed: 12/17/2022] Open
Abstract
PURPOSE The aim of this study was to compare the acoustic radiation force impulse elastography (ARFI-e) values of the renal cortical parenchyma in children with acute glomerulonephritis (AGN) and healthy children, and to determine a cut-off point for the diagnosis of AGN. METHODS This prospective study included 30 children with biopsy-proven AGN and 30 healthy children. All the children underwent renal ARFI-e measurements. Values were obtained from the upper, middle, and lower zones of the right kidney parenchyma. A total of nine ARFI-e measurements (three from each zone) were made. Statistical analyses were conducted of the mean elastography values (MEVs) of the children in both groups. RESULTS In the patient group, the MEVs measured from the upper, middle and lower zones of the right kidney were 3.42±0.42 m/s, 3.45±0.45 m/s, and 3.39±0.39 m/s (average, 3.42±0.34 m/s), respectively. In the healthy control group, the MEVs measured from the upper, middle, and lower zones of the right kidney were 2.85±0.63 m/s, 2.85±0.68 m/s, and 2.86±0.66 m/s (average, 2.85±0.57 m/s), respectively. The MEVs in all zones were significantly higher in the patient group than in the healthy group (P<0.001). The cut-off values determined to predict AGN in the upper, middle, and lower zones of the kidney were 2.74 m/s (sensitivity, 96.67%; specificity, 46.67%), 2.71 m/s (sensitivity, 96.67%; specificity, 53.33%), and 2.81 m/s (sensitivity, 93.33%; specificity, 56.67%), respectively. CONCLUSION The ARFI-e technique can be considered as a non-invasive, easily applicable, auxiliary method for the early diagnosis of AGN.
Collapse
Affiliation(s)
- Burak Yoǧurtçuoǧlu
- Department of Radiology, Faculty of Medicine, Gaziantep University, Üniversite Bulvarı, Șehitkamil, Turkey
| | - Çaǧrı Damar
- Department of Radiology, Faculty of Medicine, Gaziantep University, Üniversite Bulvarı, Șehitkamil, Turkey
| |
Collapse
|
6
|
Olchowy C, Olchowy A, Pawluś A, Więckiewicz M, Sconfienza LM. Stiffness of the Masseter Muscle in Children-Establishing the Reference Values in the Pediatric Population Using Shear-Wave Elastography. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18189619. [PMID: 34574544 PMCID: PMC8469581 DOI: 10.3390/ijerph18189619] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/23/2021] [Accepted: 09/09/2021] [Indexed: 12/16/2022]
Abstract
In children, the quality and muscle function are altered in many pathologic conditions, including temporomandibular disorders. Although several methods have been used to evaluate muscle tonus, none became a golden standard. Moreover, the masseter muscle characteristics in children have not been investigated to date. This study aimed to measure the stiffness of the masseter muscle using shear-wave elastography in healthy children. We enrolled 30 healthy children (mean age 10.87 ± 3.38 years). The stiffness of masseter muscles was measured with shear wave elastography. Stiffness for the total sample was 6.37 ± 0.77 kPa. A comparison of the measurements did not show significant differences between the right and the left masseter muscles (left—6.47 ± 0.78 kPa; right—6.24 ± 0.76 kPa; p = 0.3546). A significant difference was seen between boys and girls (boys—5.94 ± 0.50 kPa; girls—6.63 ± 0.80; p = 0.0006). Shear-wave elastography is a promising diagnostic tool. It may help to detect changes in the stiffness of the masseter muscle and draw attention to pathological processes within the jaw muscles. Directions for further research shall include determining stiffness values in pathological conditions and the impact of biological and functional factors on the stiffness of the masseter muscle.
Collapse
Affiliation(s)
- Cyprian Olchowy
- Department of Oral Surgery, Wroclaw Medical University, 50-425 Wroclaw, Poland
- Correspondence:
| | - Anna Olchowy
- Department of Experimental Dentistry, Wroclaw Medical University, 50-425 Wroclaw, Poland; (A.O.); (M.W.)
| | - Aleksander Pawluś
- Department of General Radiology, Provincial Specialist Hospital in Legnica, 59-220 Legnica, Poland;
| | - Mieszko Więckiewicz
- Department of Experimental Dentistry, Wroclaw Medical University, 50-425 Wroclaw, Poland; (A.O.); (M.W.)
| | - Luca Maria Sconfienza
- Unità Operativa di Radiologia Diagnostica e Interventistica, IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy;
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20161 Milano, Italy
| |
Collapse
|
7
|
Technical feasibility and correlations between shear-wave elastography and histology in kidney fibrosis in children. Pediatr Radiol 2021; 51:1879-1888. [PMID: 33893848 DOI: 10.1007/s00247-021-05068-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 09/18/2020] [Accepted: 03/21/2021] [Indexed: 12/17/2022]
Abstract
BACKGROUND Ultrasound elastography has been suggested for assessing organ fibrosis. OBJECTIVE To study the feasibility of shear-wave elastography in children with kidney disease and the correlation between elasticity and kidney fibrosis in order to reduce the indications for kidney biopsy and its complications. MATERIALS AND METHODS Four operators measured kidney elasticity in children with kidney diseases or transplants, all of whom also had a renal biopsy. We assessed the feasibility and the intraobserver variability of the elasticity measurements for each probe used and each kidney explored. Then we tested the correlation between elasticity measurements and the presence of fibrosis. RESULTS Overall, we analyzed 95 children and adolescents, 31 of whom had renal transplant. Measurements with the convex probe were possible in 100% of cases. Linear probe analysis was only possible for 20% of native kidneys and 50% of transplants. Intraobserver variabilities ranged from moderate to high, depending on the probe and kidney studied. Elasticity was higher with the linear probe than with the convex probe (P<0.001 for left kidney and P=0.03 for right kidney). Measurements did not differ from one kidney to another in the same child. Elasticity and fibrosis were both higher in transplant patients (P=0.02 with convex probe; P=0.01 with linear probe; P=0.04 overall). There was no correlation between elasticity and fibrosis. CONCLUSION Of the devices used in this work, kidney elastography was more accurately analyzed with a convex probe. Our study did not identify any correlation between elasticity and kidney fibrosis.
Collapse
|
8
|
Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Mohd Sharif NH, Abas NK, Ng KH. Stiffness and Anisotropy Effect on Shear Wave Elastography: A Phantom and in Vivo Renal Study. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:34-45. [PMID: 31594681 DOI: 10.1016/j.ultrasmedbio.2019.08.011] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2019] [Revised: 08/08/2019] [Accepted: 08/16/2019] [Indexed: 05/28/2023]
Abstract
Tissue elasticity is related to the pathologic state of kidneys and can be measured using shear wave elastography (SWE). However, SWE quantification has not been rigorously validated. The aim of this study was to evaluate the accuracy of SWE-measured stiffness and the effect of tissue anisotropy on SWE measurements. Point SWE (pSWE), 2-D SWE and dynamic mechanical analysis (DMA) were used to measure stiffness and evaluate the effect of tissue anisotropy on the measurements. SWE and DMA were performed on phantoms of different gelatin concentrations. In the tissue anisotropy study, SWE and DMA were performed on the outer cortex of sheep kidneys. In the in vivo study, 15 patients with different levels of interstitial fibrosis were recruited for pSWE measurements. Another 10 healthy volunteers were recruited for tissue anisotropy studies. SWE imaging revealed a non-linear increase with gelatin concentration. There was a significant correlation between pSWE and 2-D SWE, leading to the establishment of a linear regression equation between the two SWE ultrasound measurements. In the anisotropy study, the median difference in stiffness between shear waves oriented at 0° and 90° towards the pyramid axis was significant. In the in vivo study, there was a strong positive linear correlation between pSWE and the percentage of interstitial fibrosis. There was a significant difference in the Young's modulus (YM) between severities of fibrosis. The mean YM values were lower in control patients than in patients with mild, moderate and severe fibrosis. YM values were also significantly higher when shear waves were oriented at 0° toward the pyramid axis. Tissue stiffness and anisotropy affects SWE measurements. These factors should be recognized before applying SWE for the interpretation of measured values.
Collapse
Affiliation(s)
- Sook Sam Leong
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; Department of Biomedical Imaging, University of Malaya Medical Centre, Kuala Lumpur, Malaysia
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia.
| | - Mohammad Nazri Md Shah
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| | - Anushya Vijayananthan
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| | | | | | | | - Kwan Hoong Ng
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
9
|
Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Ng KH. Comparison of Shear Wave Elastography and Conventional Ultrasound in Assessing Kidney Function as Measured Using 51Cr-ethylenediaminetetraacetic Acid and 99Tc-Dimercaptosuccinic Acid. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1417-1426. [PMID: 30962016 DOI: 10.1016/j.ultrasmedbio.2019.01.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 01/25/2019] [Accepted: 01/28/2019] [Indexed: 05/28/2023]
Abstract
The purpose of this study was to assess the potential of shear wave elastography (SWE) as an indicator of abnormal kidney function defined by radiolabeled glomerular filtration rate (GFR). Fifty-seven patients referred for 51Cr-ethylenediaminetetraacetic acid GFR and 99mTc-dimercaptosuccinic acid renal scintigraphy were included. Young's modulus (YM) measured with SWE and kidney length, volume, cortical thickness and parenchymal echogenicity measured with conventional ultrasound were correlated with patients' GFR and renal scintigraphy results. Spearman correlation coefficients between SWE and GFR were negative for the right (r = -0.635, p < 0.0001) and left (r = -0.817, p < 0.0001) kidneys. Positive correlations between left renal cortical thickness (r = 0.381, p = 0.04) and left kidney volume (r = 0.356, p = 0.019) with GFR were reported. SWE correctly predicted the dominant functioning kidney in 94.7% of cases. The area under the receiver operating characteristic curve for SWE (0.800) was superior to that for conventional ultrasound (0.252-0.415). The cutoff value of ≥5.52 kPa suggested a kidney function ≤60 mL/min/1.73 m2 (82.4% sensitivity and 76.2% specificity). SWE has advantages over conventional ultrasound in assessing kidney function and distinguishing the dominant functioning kidney.
Collapse
Affiliation(s)
- Sook Sam Leong
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; Department of Biomedical Imaging, University of Malaya Medical Centre, Kuala Lumpur, Malaysia
| | - Jeannie Hsiu Ding Wong
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| | - Mohammad Nazri Md Shah
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia.
| | - Anushya Vijayananthan
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| | | | - Kwan Hoong Ng
- Department of Biomedical Imaging, University of Malaya, Kuala Lumpur, Malaysia; University of Malaya Research Imaging Centre, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
10
|
|
11
|
Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Ng KH. Shear wave elastography in the evaluation of renal parenchymal stiffness in patients with chronic kidney disease. Br J Radiol 2018; 91:20180235. [PMID: 29869920 DOI: 10.1259/bjr.20180235] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
OBJECTIVE To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR). METHODS The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR. RESULTS Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity). CONCLUSION SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.
Collapse
Affiliation(s)
- Sook Sam Leong
- 1 Department of Biomedical Imaging, University of Malaya , Kuala Lumpur , Malaysia.,2 Department of Biomedical Imaging, University of Malaya Medical Centre , Kuala Lumpur , Malaysia
| | - Jeannie Hsiu Ding Wong
- 1 Department of Biomedical Imaging, University of Malaya , Kuala Lumpur , Malaysia.,3 University of Malaya Research Imaging Centre, University of Malaya , Kuala Lumpur , Malaysia
| | - Mohammad Nazri Md Shah
- 1 Department of Biomedical Imaging, University of Malaya , Kuala Lumpur , Malaysia.,3 University of Malaya Research Imaging Centre, University of Malaya , Kuala Lumpur , Malaysia
| | - Anushya Vijayananthan
- 1 Department of Biomedical Imaging, University of Malaya , Kuala Lumpur , Malaysia.,3 University of Malaya Research Imaging Centre, University of Malaya , Kuala Lumpur , Malaysia
| | - Maisarah Jalalonmuhali
- 4 Division of Nephrology, Department of Medicine, University of Malaya , Kuala Lumpur , Malaysia
| | - Kwan Hoong Ng
- 1 Department of Biomedical Imaging, University of Malaya , Kuala Lumpur , Malaysia.,3 University of Malaya Research Imaging Centre, University of Malaya , Kuala Lumpur , Malaysia
| |
Collapse
|