Accuracy of intraoperative approximation of pelvic tilt using preoperative standing radiographs. J Orthop 2024; 54:120-123. [PMID: 38560587 PMCID: PMC10979016 DOI: 10.1016/j.jor.2024.03.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 03/12/2024] [Accepted: 03/14/2024] [Indexed: 04/04/2024] Open
Abstract
Background Anterior approach surgeons who utilize intraoperative fluoroscopy often try to match a preoperative radiograph as a reference for intraoperative cup position. Every degree of inaccuracy in tilt leads to a roughly 0.7° change in anteversion. This study aimed to determine how closely pelvic tilt (PT) is approximated intraoperatively when compared to preoperative anteroposterior (AP) radiographs. Methods This was a retrospective review of 193 primary THA's done by 2 surgeons at an academic tertiary referral center between September 2021-January 2023. There were 24 patients excluded for distorted anatomy, post-traumatic arthritis, insufficient x-rays, or a sacroiliac joint that could not be visualized on film. Data collected included age and BMI. PT was calculated using the formula, Tilt = -(ln((B/A) x (1/0.483)))/0.051. Value A is the distance from the base of the SI joint to the superior margin of the obturator foramen; value B is the height of the obturator foramen. Results Mean preoperative PT was 0.2° versus intraoperative PT was 3.4° (p < 0.001). Mean absolute difference was 6.5°. 48% of patients (n = 81) had an absolute difference less than 5°, 31% (n = 52) between 5° and 10°, 14% (n = 24) between 10° and 15°, and 7% (n = 12) greater than 15°. There was no correlation between BMI or age and PT discrepancy. Conclusion Of the patients, 21% had a discrepancy of 10° or greater between their preoperative radiographs and intraoperative fluoroscopic images. Surgeons should be aware of potential errors in cup positioning and be particularly diligent in high-risk cases.
Collapse
|
2
|
Comparison between accuracy of augmented reality computed tomography-based and portable augmented reality-based navigation systems for cup insertion in total hip arthroplasty. Sci Rep 2024; 14:8332. [PMID: 38594498 PMCID: PMC11004011 DOI: 10.1038/s41598-024-59115-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 04/08/2024] [Indexed: 04/11/2024] Open
Abstract
Augmented reality (AR) has been used for navigation during total hip arthroplasty (THA). AR computed tomography (CT)-based navigation systems and AR-based portable navigation systems that use smartphones can also be used. This study compared the accuracy of cup insertion during THA using AR-CT-based and portable AR-based navigation systems. Patients with symptomatic hip disease who underwent primary THA in the supine position using both AR CT-based and portable AR-based navigation systems simultaneously between October 2021 and July 2023 were included. The primary outcome of this study was the absolute difference between cup angles in the intraoperative navigation record and those measured on postoperative CT. The secondary outcome was to determine the factors affecting the absolute value of the navigation error in radiographic inclination (RI) and radiographic anteversion (RA) of the cup, including sex, age, body mass index, left or right side, approach, and preoperative pelvic tilt. This study included 94 consecutive patients. There were 11 men and 83 women, with a mean age of 68 years. The mean absolute errors of RI were 2.7° ± 2.0° in the AR CT-based and 3.3° ± 2.4° in the portable AR-based navigation system. The mean absolute errors of RA were 2.5° ± 2.1° in the AR CT-based navigation system and 2.3° ± 2.2° in the portable AR-based navigation system. No significant differences were observed in RI or RA of the cup between the two navigation systems (RI: p = 0.706; RA: p = 0.329). No significant factors affected the absolute value of the navigation errors in RI and RA. In conclusion, there were no differences in the accuracy of cup insertion between the AR CT-based and portable AR-based navigation systems.
Collapse
|
3
|
Robotics and Navigation Do Not Affect the Risk of Periprosthetic Joint Infection Following Primary Total Hip Arthroplasty: A Propensity Score-Matched Cohort Analysis. J Bone Joint Surg Am 2024; 106:582-589. [PMID: 38324646 DOI: 10.2106/jbjs.23.00289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/09/2024]
Abstract
BACKGROUND The use of computer navigation or robotic assistance during primary total hip arthroplasty (THA) has yielded numerous benefits due to more accurate component positioning. The utilization of these tools is generally associated with longer operative times and also necessitates additional surgical equipment and personnel in the operating room. Thus, the aim of this study was to evaluate the impact of technology assistance on periprosthetic joint infection (PJI) after primary THA. METHODS We retrospectively reviewed the records for 12,726 patients who had undergone primary THA at a single high-volume institution between 2018 and 2021. Patients were stratified by surgical technique (conventional THA, computer-navigated THA [CN-THA], or robotic-assisted THA [RA-THA]) and were matched 1:1 with use of propensity score matching. Univariate and logistic regression analyses were performed to compare the rates of PJI within 90 days postoperatively between the cohorts. RESULTS After propensity score matching, there were 4,006 patients in the THA versus RA-THA analysis (2,003 in each group) and 5,288 patients in the THA versus CN-THA analysis (2,644 in each group). CN-THA (p < 0.001) and RA-THA (p < 0.001) were associated with longer operative times compared with conventional THA by 3 and 11 minutes, respectively. The rates of PJI after conventional THA (0.2% to 0.4%) were similar to those after CN-THA (0.4%) and RA-THA (0.4%). On the basis of logistic regression, the development of PJI was not associated with the use of computer navigation (odds ratio [OR], 1.8 [95% confidence interval (CI), 0.7 to 5.3]; p = 0.232) or robotic assistance (OR, 0.9 [95% CI, 0.3 to 2.3]; p = 0.808). CONCLUSIONS Despite longer operative times associated with the use of computer navigation and robotic assistance, the use of these tools was not associated with an increased risk of PJI within 90 days after surgery. LEVEL OF EVIDENCE Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
4
|
Patient-reported outcome differences for navigated and robot-assisted total hip arthroplasty frequently do not achieve clinically important differences: a systematic review. Hip Int 2024:11207000241241797. [PMID: 38566302 DOI: 10.1177/11207000241241797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Total hip arthroplasty (THA) using computer-assisted navigation (N-THA) and robot-assisted surgery (RA-THA) has been increasingly adopted to improve implant positioning and offset/leg-length restoration. Whether clinically meaningful differences in patient-reported outcomes (PROMs) compared to conventional THA (C-THA) are achieved with intraoperative technology has not been established. This systematic review aimed to assess whether published relative PROM improvements with technology use in THA achieved minimal clinically important differences (MCIDs). METHODS PubMed/MEDLINE/Cochrane Library were systematically reviewed for studies comparing PROMs for primary N-THA or RA-THA with C-THA as the control group. Relative improvement differences between groups were compared to established MCID values. Reported clinical and radiographic differences were assessed. Review of N-THA and RA-THA literature yielded 6 (n = 2580) and 10 (n = 2786) studies, respectively, for analyses. RESULTS Statistically significant improvements in postoperative PROM scores were reported in 2/6 (33.3%) studies comparing N-THA with C-THA, though only 1 (16.7%) reported clinically significant relative improvements. Statistically significant improvements in postoperative PROMs were reported in 6/10 (60.0%) studies comparing RA-THA and C-THA, though none reported clinically significant relative improvements. Improved radiographic outcomes for N-THA and RA-THA were reported in 83.3% and 70.0% of studies, respectively. Only 1 study reported a significant improvement in revision rates with RA-THA as compared to C-THA. CONCLUSIONS Reported PROM scores in studies comparing N-THA or RA-THA to C-THA often do not achieve clinically significant relative improvements. Future studies reporting PROMs should be interpreted in the context of validated MCID values to accurately establish the clinical impact of intraoperative technology.
Collapse
|
5
|
Does a Commercially Available Augmented Reality-based Portable Hip Navigation System Improve Cup Positioning During THA Compared With the Conventional Technique? A Randomized Controlled Study. Clin Orthop Relat Res 2024; 482:458-467. [PMID: 37650864 PMCID: PMC10871751 DOI: 10.1097/corr.0000000000002819] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 07/19/2023] [Indexed: 09/01/2023]
Abstract
BACKGROUND Portable hip navigation systems have been developed to combine the accuracy of cup positioning by large console navigation systems with the ease of use and convenience of conventional surgical techniques. Although a novel augmented reality-based portable hip navigation system using a smartphone (AR navigation) has become available recently, no studies, to our knowledge, have compared commercially available AR navigation with the conventional technique. Additionally, no studies, except for those from designer-surgeon series, have demonstrated the results of AR navigation. QUESTIONS/PURPOSES (1) Does intraoperative use of commercially available AR navigation improve cup positioning compared with the conventional technique? (2) Are operative factors, clinical scores, and postoperative course different between the two groups? METHODS In this randomized trial, 72 patients undergoing THA were randomly assigned to undergo either commercially available AR navigation or a conventional technique for cup placement. All patients received the same cementless acetabular cups through a posterior approach in the lateral decubitus position. The primary outcome of the present study was cup positioning, including the absolute differences between the intended target and angle achieved, as well as the number of cups inside the Lewinnek safe zone. Our target cup position was 40° abduction and 20° anteversion. Secondary outcomes were operative factors, between-group difference in improvement in the Hip Disability and Osteoarthritis Outcome Score (HOOS), and the postoperative course, including the operative time (between the start of the surgical approach and skin closure), procedure time (between the first incision and skin closure, including the time to insert pins, registration, and transfer and redrape patients in the navigation group), time taken to insert pins and complete registration in the navigation group, intraoperative and postoperative complications, and reoperations. The minimum follow-up period was 6 months, because data regarding the primary outcome-cup positioning-were collected within 1 week after surgery. The between-group difference in improvement in HOOS, which was the secondary outcome, was much lower than the minimum clinically important difference for the HOOS. No patients in either group were lost to follow-up, and there was no crossover (the randomized treatment was performed in all patients, so there was no difference between an intention-to-treat and a per-protocol analysis). RESULTS The use of the commercially available AR navigation slightly improved cup positioning compared with the conventional technique in terms of the absolute difference between the desired and achieved amounts of cup abduction and anteversion (which we defined as "absolute differences"; median 1° [IQR 0° to 4.0°] versus median 5° [IQR 3.0° to 7.5°], difference of medians 4°; p < 0.001 and median 2° [IQR 1.9° to 3.7°] versus median 5° [IQR 3.2° to 9.7°], difference of medians 2°; p = 0.001). A higher proportion of cups were placed inside the Lewinnek safe zone in the navigation group than in the control group (94% [34 of 36] compared with 64% [23 of 36]; p < 0.001). Median operative times were not different between the two groups (58 minutes [IQR 49 to 72 minutes] versus 57 minutes [IQR 49 to 69 minutes], difference of medians 1 minute; p = 0.99). The median procedure time was longer in the navigation group (95 minutes [IQR 84 to 109 minutes] versus 57 minutes [IQR 49 to 69 minutes], difference of medians 38 minutes; p < 0.001). There were no differences between the two groups in improvement in HOOS (27 ± 17 versus 28 ± 19, mean difference -1 [95% CI -9.5 to 7.4]; p = 0.81). In the navigation group, no complications occurred in the pin sites; however, one anterior dislocation occurred. In the conventional group, one hip underwent reoperation because of a deep infection. CONCLUSION Although the use of commercially available AR navigation improved cup positioning in THA, the improvement in clinical scores and postoperative complication rates were not different between the two groups, and the overall magnitude of the difference in accuracy was small. Future studies will need to determine whether the improvement in the percentage of hips inside the Lewinnek safe zone results in differences in late dislocation or polyethylene wear, and whether such benefits-if any-justify the added costs and surgical time. Until or unless more compelling evidence in favor of the new system emerges, we recommend against widespread use of the system in clinical practice. LEVEL OF EVIDENCE Level Ⅱ, therapeutic study.
Collapse
|
6
|
Measurement accuracy of the acetabular cup position using an inertial portable hip navigation system with patients in the lateral decubitus position. Sci Rep 2024; 14:1158. [PMID: 38212422 PMCID: PMC10784560 DOI: 10.1038/s41598-024-51785-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Accepted: 01/09/2024] [Indexed: 01/13/2024] Open
Abstract
Accurate cup placement is critical to ensure satisfactory outcomes after total hip arthroplasty. Portable hip navigation systems are novel intraoperative guidance tools that achieve accurate cup placement in the supine position; however, accuracy in the lateral decubitus position is under debate. A new inertial portable navigation system has recently become available. The present study investigated the accuracy of measurements of the cup position in 54 patients in the lateral decubitus position using this system and compared it with that by a goniometer. After cup placement, cup abduction and anteversion were measured using the system and by the goniometer, and were then compared with postoperatively measured angles. Absolute measurement errors with the system were 2.8° ± 2.6° for cup abduction and 3.9° ± 2.9° for anteversion. The system achieved 98 and 96% measurement accuracies within 10° for cup abduction and anteversion, respectively. The system was more accurate than the goniometer for cup anteversion (p < 0.001), but not for abduction (p = 0.537). The system uses a new registration method of the pelvic reference plane and corrects intraoperative pelvic motion errors, which may affect measurement accuracy. In the present study, reliable and reproducible intraoperative measurements of the cup position were obtained using the inertial portable navigation system.
Collapse
|
7
|
Varying Complication Rates and Increased Costs in Technology-Assisted Total Hip Arthroplasty Versus Conventional Instrumentation in 1,372,300 Primary Total Hips. J Arthroplasty 2023:S0883-5403(23)01211-1. [PMID: 38103802 DOI: 10.1016/j.arth.2023.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 12/08/2023] [Accepted: 12/12/2023] [Indexed: 12/19/2023] Open
Abstract
BACKGROUND The use of technology allows surgeons increased precision in component positioning in total hip arthroplasty (THA). The objective of this study was to compare (1) perioperative complications and (2) resource utilizations between robotic-assisted (RA) and computer-navigated (CN) versus conventional instrumenttaion (CI) THA. METHODS A retrospective cohort study was performed using a large national database to identify patients undergoing unilateral, primary elective THA from January 1, 2016 to December 31, 2019 using RA, CN, or CI. There were 1,372,300 total patients identified and included RA (29,735), CN (28,480), and CI (1,314,085) THA. Demographics, complications, lengths of stay, dispositions, and costs were compared between the cohorts. Binary logistic regression analyses were performed. RESULTS The use of RA THA led to lower rates of intraoperative fracture (0.22% versus 0.39%), delirium (0.1% versus 0.2%), postoperative anemia (14.4% versus 16.7%), higher myocardial infarction (0.13% versus 0.08%), renal failure (1.7% versus 1.6%), blood transfusion (2.0% versus 1.9%), and wound dehiscence (0.02% versus 0.01%) compared to CI THA. The use of CN led to lower rates of respiratory complication (0.5% versus 0.8%), renal failure (1.1% versus 1.6%), blood transfusion (1.3% versus 1.9%), and pulmonary embolism (0.02% versus 0.1%) compared to CI THA. Total costs were increased in RA ($17,729 versus $15,977) and CN ($22,529 versus $15,977). Lengths of hospital stay were decreased in RA (1.8 versus 1.9 days) and CN (1.7 versus 1.9 days). CONCLUSIONS Perioperative complication rates vary in technology-assisted THA, with higher rates in RA THA and lower rates in CN THA, relative to CI THA. Both RA THA and CN THA were associated with more costs, shorter postoperative hospital stays, and higher rates of discharge home compared to CI THA.
Collapse
|
8
|
CT-based navigation for total hip arthroplasty: a meta-analysis. Eur J Med Res 2023; 28:443. [PMID: 37853456 PMCID: PMC10583311 DOI: 10.1186/s40001-023-01437-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 10/07/2023] [Indexed: 10/20/2023] Open
Abstract
INTRODUCTION Computer tomography (CT) based navigation is considered by some authors as an advance in total hip arthroplasty (THA). A meta-analysis was conducted to compare CT based versus conventional THA in terms of surgical duration of the procedure, leg length difference, acetabular cup position, and rate of dislocation. MATERIAL AND METHODS The present study was conducted according to the PRISMA 2020. In December 2022, the following databases were accessed: PubMed, Web of Science, Google Scholar, Embase with no time constrain. All the clinical studies comparing CT based navigation versus the conventional THA were accessed. RESULTS Data from 1801 procedures were collected. The mean age of the patients was 61.6 ± 5.3 years, and the mean BMI was 26.9 ± 2.3 kg/m2. There was between studies comparability at baseline in terms of age, BMI, pain score, Harris hip score, leg length discrepancy (P > 0.1). The navigated group demonstrated lower leg length discrepancy (P = 0.02), and lower degrees of cup anteversion (P = 0.002). Similarity was found in cup inclination (P = 0.98), surgical duration (P = 0.3), and the rate of dislocation (P = 0.6). CONCLUSION CT guided THA may have the potential to increase the accuracy of acetabular positioning and reduce the leg length discrepancy. Current evidence is very limited and heterogeneous, and no recommendations can be inferred. Further investigations are required to definitely clarify the role of CT based THA in current practice.
Collapse
|
9
|
Does fluoroscopy improve baseplate position compared to conventional technique in reverse shoulder arthroplasty? A preliminary study. Shoulder Elbow 2023; 15:15-26. [PMID: 36895612 PMCID: PMC9990097 DOI: 10.1177/17585732211020657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Revised: 05/07/2021] [Accepted: 05/09/2021] [Indexed: 11/15/2022]
Abstract
Background Accurate placement of glenoid component in reverse shoulder arthroplasty remains a challenge for surgeons of all levels of expertise; however, no studies have evaluated the utility of fluoroscopy as a surgical assistance method. Methods Prospective comparative study of 33 patients undergoing primary reverse shoulder arthroplasty during a 12-month period. Fifteen patients had a baseplate placed using the conventional "free hand" technique (control group), and 18 patients using intraoperative fluoroscopy assistance group, in a case-control design. Postoperative glenoid position was evaluated on postoperative Computed Tomography (CT) scan. Results The mean deviation of version and inclination for fluoroscopy assistance vs. control group was 1.75° (0.675-3.125) vs. 4.2° (1.975-10.45) (p = .015), and 3.85° (0-7.225) vs. 10.35° (4.35-18.75) (p = .009). The distance from the central peg midpoint to the inferior glenoid rim (fluoroscopy assistance 14.61 mm/control 4.75 mm, p = .581) and the surgical time (fluoroscopy assistance 1.93 ± 0.57/control 2.18 ± 0.44 h, p = .400) showed no differences, with an average radiation dose of 0.45 mGy and fluoroscopy time of 14 s. Conclusions Accurate axial and coronal scapular plane positioning of glenoid component is improved with intraoperative fluoroscopy at the cost of a greater radiation dose and without differences in surgical time. Comparative studies are needed to determine whether their use in relation to more expensive surgical assistance systems result in similar effectiveness.L evel of evidence : Level III, therapeutic study.
Collapse
|
10
|
Robotic Assistance for Posterior Approach Total Hip Arthroplasty Is Associated With Lower Risk of Revision for Dislocation When Compared to Manual Techniques. J Arthroplasty 2022; 37:1124-1129. [PMID: 35124193 DOI: 10.1016/j.arth.2022.01.085] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2021] [Revised: 01/25/2022] [Accepted: 01/26/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Robotic-assistance total hip arthroplasty (RA-THA) and computer navigation THA (CN-THA) have been shown to improve accuracy of component positioning compared to manual techniques; however, controversy exists regarding clinical benefit. Moreover, these technologies may expose patients to risks. The purpose of this study is to compare rates of intraoperative fracture and complications requiring reoperation within 1 year for posterior approach RA-THA, CN-THA, and THA with no technology (Manual-THA). METHODS In total, 13,802 primary, unilateral, elective, posterior approach THAs (1770 RA-THAs, 3155 CN-THAs, and 8877 Manual-THAs) were performed at a single institution between 2016 and 2020. Intraoperative fractures and reoperations within 1 year of the index procedure were identified. Cohorts were balanced using inverse probability of treatment weight based on age, gender, body mass index, femoral cementation, history of spine fusion, and Charlson Comorbidity Index. Logistic regression was performed to create odds ratios for complications. Additional regression analysis for dislocation was performed, adjusting for dual mobility and femoral head size. RESULTS There were no differences in intraoperative fracture and postoperative complication rates between the groups (P = .521). RA-THA had a 0.3 odds ratio (95% confidence interval 0.1-0.9, P = .046) compared to Manual-THA for reoperation due to dislocation. CN-THA had an odds ratio of 3.0 for reoperation due to dislocation (95% confidence interval 0.8-11.3, P = .114) compared to RA-THA. The remaining complication odds ratios, including those for infection, loosening, dehiscence, and "other" were similar between the groups. CONCLUSION RA-THA is associated with lower risk of revision for dislocation within 1 year of index surgery, when compared to Manual-THA performed through the posterior approach.
Collapse
|
11
|
Imageless navigation for primary total hip arthroplasty: a meta-analysis study. J Orthop Traumatol 2022; 23:21. [PMID: 35426527 PMCID: PMC9012775 DOI: 10.1186/s10195-022-00636-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 02/26/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND There has been a growing interest in imageless navigation for primary total hip arthroplasty (THA). Its superiority over standard THA is debated. This meta-analysis compared surgical duration, implant positioning, Harris Hip Score and rate of dislocation of imageless navigation versus conventional THA. METHODS The present study was conducted according to the PRISMA 2020 guidelines. All the clinical trials comparing imageless navigation versus conventional for primary THA were accessed. In January 2022, the following databases were accessed: PubMed, Web of Science, Google Scholar and Embase. No time constraints were used for the search. The outcomes of interest were to compare cup inclination and anteversion, leg length discrepancy, surgical duration, Harris Hip Score and rate of dislocation of imageless navigation versus conventional THA. RESULTS Twenty-one studies (2706 procedures) were retrieved. Fifty-two percent of patients were women. There was between-group comparability at baseline in terms of age, body mass index (BMI), visual analogue scale, Harris Hip Score and leg length discrepancy (P > 0.1). Compared with conventional THA, the navigated group demonstrated slightly lower leg length discrepancy (P = 0.02) but longer duration of the surgical procedure (P < 0.0001). Cup anteversion (P = 0.6) and inclination (P = 0.5), Harris Hip Score (P = 0.1) and rate of dislocation (P = 0.98) were similar between the two interventions. CONCLUSION Imageless navigation may represent a viable option for THA.
Collapse
|
12
|
Comparison of Surgical Time, Short-term Adverse Events, and Implant Placement Accuracy Between Manual, Robotic-assisted, and Computer-navigated Total Hip Arthroplasty: A Network Meta-analysis of Randomized Controlled Trials. J Am Acad Orthop Surg Glob Res Rev 2022; 6:e21.00200. [PMID: 35472191 PMCID: PMC10566925 DOI: 10.5435/jaaosglobal-d-21-00200] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Accepted: 02/12/2022] [Indexed: 01/13/2023]
Abstract
INTRODUCTION Recent years have observed the increasing utilization of robotic-assisted and computer navigation techniques in total hip arthroplasty (THA), given the proposed benefits of enhanced consistency and precision in implant placement. The purpose of this study was to conduct a systematic review of randomized controlled trials (RCTs) to determine whether differences in surgical times, adverse events, and implant positioning existed between manual, robotic-assisted, and computer navigation THA. METHODS PubMed, OVID/MEDLINE, and Cochrane databases were queried for RCTs comparing robotic-assisted versus manual THA and computer navigation versus manual THA at a minimum 1-year follow-up. Frequentist model network meta-analyses with P-scores were conducted to compare revisions, complications, and surgical times among the three treatment groups. A random-effects meta-analysis between computer navigation and manual THAs was conducted to analyze cup positioning because no robotic-assisted THA studies reported this outcome. RESULTS Five RCTs compared robotic-assisted and manual THAs, while seven compared computer navigation and manual THAs. manual THA was associated with significantly reduced surgical time in comparison with computer navigation (mean difference: 23.3 minutes) and robotic-assisted THAs (mean difference: 8.6 minutes; P < 0.001). No difference was observed in the incidence of all-cause complications (computer navigation: 1.7%, manual: 6.6%, and robotic-assisted: 16.2%) or revisions (computer navigation: 1.0%, manual: 1.7%, and robotic-assisted 4.8%) among the three treatment groups based on the network meta-analysis. In three studies that reported acetabular implant positioning, computer navigation had a significantly higher percentage of acetabular cups placed in the Lewinnek "safe zone" compared with manual THA (79% versus 52%; P = 0.02). CONCLUSIONS manual THA results in markedly shorter surgical times and a similar incidence of complications and revisions compared with robotic-assisted and computer navigation THAs, given the sample sizes available for study. However, computer navigation THA led to increased precision in the placement of acetabular implants.
Collapse
|
13
|
Comparison of the accuracies of computed tomography-based navigation and image-free navigation for acetabular cup insertion in total hip arthroplasty in the lateral decubitus position. Comput Assist Surg (Abingdon) 2021; 26:69-76. [PMID: 34874219 DOI: 10.1080/24699322.2021.1949494] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Image-free navigation has been proven as reliable as that using computed tomography (CT) in positioning the acetabular cup in total hip arthroplasty (THA), but previous studies rarely included hip dysplasia cases. The purpose of the present study was to determine the accuracies of CT-based navigation and image-free navigation for acetabular cup insertion, including hip dysplasia cases. Sixty-three hips were studied, including 57 with hip dysplasia. The hips were divided into two groups based on the registration point of image-free navigation. In Group I, the ipsilateral anterior superior iliac spine (ASIS) and the L5 spinous process were registered in 31 hips. In Group II, bilateral ASIS points were registered in 32 hips. Final component orientation was measured from postoperative CT scans. The accuracy of cup orientation was compared between CT-based and image-free navigation. In Group I, the cup inclination was more accurate with CT-based navigation (1.9°) than with image-free navigation (4.4°, p=.009). Cup anteversion was also more accurate with CT-based navigation (2.9°) than with image-free navigation (7.1°, p<.001). In Group II, the accuracies of cup inclination and anteversion showed no differences between CT-based and image-free navigation. The accuracy of cup positioning was better with CT-based navigation than with image-free navigation when the ipsilateral ASIS and L5 spinous process were digitized. However, accuracy was similar when bilateral ASIS points were digitized.
Collapse
|
14
|
Fragility Index as a Measure of Randomized Clinical Trial Quality in Adult Reconstruction: A Systematic Review. Arthroplast Today 2021; 11:239-251. [PMID: 34692962 PMCID: PMC8517286 DOI: 10.1016/j.artd.2021.08.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 08/08/2021] [Accepted: 08/29/2021] [Indexed: 12/16/2022] Open
Abstract
Background The Fragility Index (FI) and Reverse Fragility Index are powerful tools to supplement the P value in evaluation of randomized clinical trial (RCT) outcomes. These metrics are defined as the number of patients needed to change the significance level of an outcome. The purpose of this study was to calculate these metrics for published RCTs in total joint arthroplasty (TJA). Methods We performed a systematic review of RCTs in TJA over the last decade. For each study, we calculated the FI (for statistically significant outcomes) or Reverse Fragility Index (for nonstatistically significant outcomes) for all dichotomous, categorical outcomes. We also used the Pearson correlation coefficient to evaluate publication-level variables. Results We included 104 studies with 473 outcomes; 92 were significant, and 381 were nonstatistically significant. The median FI was 6 overall and 4 and 7 for significant and nonsignificant outcomes, respectively. There was a positive correlation between FI and sample size (R = 0.14, P = .002) and between FI and P values (R = 0.197, P = .000012). Conclusions This study is the largest evaluation of FI in orthopedics literature to date. We found a median FI that was comparable to or higher than FIs calculated in other orthopedic subspecialties. Although the mean and median FIs were greater than the 2 recommended by the American Academy of Orthopaedic Surgeons Clinical Practice Guidelines to demonstrate strong evidence, a large percentage of studies have an FI < 2. This suggests that the TJA literature is on par or slightly better than other subspecialties, but improvements must be made. Level of Evidence Level I; Systematic Review.
Collapse
|
15
|
The Use of Computer Navigation in Total Hip Arthroplasty Is Associated with a Reduced Rate of Revision for Dislocation: A Study of 6,912 Navigated THA Procedures from the Australian Orthopaedic Association National Joint Replacement Registry. J Bone Joint Surg Am 2021; 103:1900-1905. [PMID: 34143758 DOI: 10.2106/jbjs.20.00950] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The use of computer navigation has been shown to produce more accurate cup positioning when compared with non-navigated total hip arthroplasty (THA), but so far there is only limited evidence to show its effect on clinical outcomes. The present study analyzed data from the Australian Orthopaedic Association National Joint Replacement Registry to assess the impact of computer navigation on the rates of all-cause revision and revision for dislocation following THA. METHODS Data for all non-navigated and navigated primary THAs performed for osteoarthritis in Australia from January 1, 2009, to December 31, 2019, were examined to assess the rate of revision. We analyzed the effects of navigation on rate, reason, and type of revision. Hazard ratios (HRs) from Cox proportional hazard models, adjusted for age, sex, and head size, were utilized. Because of known prosthesis-specific differences in outcomes, we performed a further analysis of the 5 acetabular and femoral component combinations most commonly used with navigation. RESULTS Computer navigation was utilized in 6,912 primary THAs for osteoarthritis, with the use of navigation increasing from 1.9% in 2009 to 4.4% of all primary THAs performed in 2019. There was no difference in the rate of all-cause revision between navigated and non-navigated THAs looking at the entire group. There was a lower rate of revision for dislocation in the navigation THA cohort. The cumulative percent revision for dislocation at 10 years was 0.4% (95% confidence interval [CI], 0.2% to 0.6%) for navigated compared with 0.8% (95% CI, 0.8% to 0.9%) for non-navigated THAs (HR adjusted for age, sex, and head size, 0.46; 95% CI, 0.29 to 0.74; p = 0.002). In the 5 component combinations most commonly used with navigation, the rate of all-cause revision was significantly lower when these components were navigated compared with non-navigated. The cumulative percent revision at 10 years for these 5 prostheses combined was 2.4% (95% CI, 1.6% to 3.4%) for navigated compared with 4.2% (95% CI, 4.0% to 4.5%) for non-navigated THAs (HR, 0.64; 95% CI, 0.48 to 0.86; p = 0.003). CONCLUSIONS This study showed that the use of computer navigation was associated with a reduced rate of revision for dislocation following THA. Furthermore, in the component combinations most commonly used with navigation there was also a reduction in the rate of all-cause revision. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
16
|
Preoperative Guidance With Weight-Bearing Computed Tomography and Patient-Specific Instrumentation in Foot and Ankle Surgery. HSS J 2021; 17:326-332. [PMID: 34539274 PMCID: PMC8436345 DOI: 10.1177/15563316211026325] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Accepted: 05/05/2021] [Indexed: 11/16/2022]
Abstract
The use of preoperative and intraoperative guidance in foot and ankle surgery has grown substantially in recent years. Weight-bearing computed tomography (WBCT) and patient-specific instrumentation (PSI) are used in total ankle arthroplasty (TAA) to achieve precise bone cutting and implant positioning, and intraoperative 3-dimensional (3D) imaging has been used to reduce complications and improve clinical outcomes in other foot and ankle surgical procedures. This narrative review of the literature focuses on the evidence supporting the use of WBCT and PSI in TAA and looks at other promising technologies used to guide foot and ankle surgery.
Collapse
|
17
|
Surgical cup placement affects the heating up of total joint hip replacements. Sci Rep 2021; 11:15851. [PMID: 34349160 PMCID: PMC8338953 DOI: 10.1038/s41598-021-95387-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 07/07/2021] [Indexed: 11/16/2022] Open
Abstract
The long-term success of highly effective total hip arthroplasty (THA) is mainly restricted by aseptic loosening, which is widely associated with friction between the head and cup liner. However, knowledge of the in vivo joint friction and resulting temperature increase is limited. Employing a novel combination of in vivo and in silico technologies, we analyzed the hypothesis that the intraoperatively defined implant orientation defines the individual joint roofing, friction and its associated temperature increase. A total of 38,000 in vivo activity trials from a special group of 10 subjects with instrumented THA implants with an identical material combination were analyzed and showed a significant link between implant orientation, joint kinematics, joint roofing and friction-induced temperature increase but surprisingly not with acting joint contact force magnitude. This combined in vivo and in silico analysis revealed that cup placement in relation to the stem is key to the in vivo joint friction and heating-up of THA. Thus, intraoperative placement, and not only articulating materials, should be the focus of further improvements, especially for young and more active patients.
Collapse
|
18
|
Robotics Versus Navigation Versus Conventional Total Hip Arthroplasty: Does the Use of Technology Yield Superior Outcomes? J Arthroplasty 2021; 36:2801-2807. [PMID: 33773864 DOI: 10.1016/j.arth.2021.02.074] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 02/15/2021] [Accepted: 02/27/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The use of technology such as navigation and robotic systems may improve the accuracy of component positioning in total hip arthroplasty (THA), but its impact on patient-reported outcome measures (PROMs) remains unclear. This study aims to elucidate the association between the use of intraoperative technology and PROMs in patients who underwent primary THA. METHODS We retrospectively reviewed a consecutive series of patients who underwent primary THA between 2016 and 2020 and answered PROM questionnaires. Patients were separated into 3 groups depending on intraoperative technology utilization: computer-assisted navigation, robotic-assisted, or no technology (conventional) THA. Forgotten Joint Score-12 and Hip disability and Osteoarthritis Outcome Score, Joint Replacemen scores were collected at various time points. Demographic differences were assessed with chi-square and analysis of variance. Mean scores between groups were compared using univariate analysis of covariance, controlling for all significant demographic differences. RESULTS Of the 1960 cases identified, 896 used navigation, 135 used robotics, and 929 used no technology. There were significant statistical differences in one-year Hip disability and Osteoarthritis Outcome Score, Joint Replacement scores (85.23 vs 85.95 vs 86.76, respectively; P = .014) and two-year Forgotten Joint Score-12 scores (64.72 vs 73.35 vs 74.63, respectively; P = .004) between the 3 groups. However, these differences did not exceed the mean clinically important differences. Length of stay was statistically longest for patients who underwent conventionally performed THA versus navigation and robotics (2.22 vs 1.46 vs 1.91, respectively; P < .001). Surgical time was significantly longer for cases performed using robotics versus navigation and conventionally (119.61 vs 90.35 vs 95.35, respectively; P < .001). CONCLUSION Statistical differences observed between all modalities are not likely to be clinically meaningful with regard to early patient-reported outcomes. Although intraoperative use of technology may improve the accuracy of implant placement, these modalities have not yet translated into improved early reported functional outcomes. LEVEL III EVIDENCE Retrospective cohort.
Collapse
|
19
|
Reduced Risk of Revision with Computer-Guided Versus Non-Computer-Guided THA: An Analysis of Manufacturer-Specific Data from the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man. JB JS Open Access 2021; 6:JBJSOA-D-21-00006. [PMID: 34337286 PMCID: PMC8318654 DOI: 10.2106/jbjs.oa.21.00006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Computer-assisted total hip arthroplasty (THA) is known to improve implantation precision, but clinical data demonstrating an improvement in survivorship and patient-reported outcome measures (PROMs) are lacking. Our aim was to compare the risk of revision, PROMs, and patient satisfaction between cohorts who underwent THA with and without the use of computer guidance. Methods We used the data set and linked PROM data of the National Joint Registry of England, Wales, Northern Ireland and the Isle of Man. Our sample included THAs performed for osteoarthritis using cementless acetabular components from a single manufacturer (cementless and hybrid THAs). An additional analysis was performed limiting the sample size to cementless-only THAs. The primary end point was revision (any component) for any reason. Kaplan-Meier survivorship analysis and an adjusted Cox proportional-hazards model were used. Results There were 41,683 non-computer-guided and 871 (2%) computer-guided cases included in our analysis of the cementless and hybrid group. There were 943 revisions in the non-computer-guided group and 7 in the computer-guided group. The cumulative revision rate at 10 years was 3.88% (95% confidence interval [CI]: 3.59% to 4.18%) for the non-computer-guided group and 1.06% (95% CI: 0.45% to 2.76%) for the computer-guided group. The Cox proportional-hazards model yielded a hazard ratio of 0.45 (95% CI: 0.21 to 0.96; p = 0.038). In the analysis of the cementless-only group, the cumulative revision rate at 10 years was 3.99% (95% CI: 3.62% to 4.38%) and 1.20% (95% CI: 0.52% to 3.12%) for the 2 groups, respectively. The Cox proportional-hazards model yielded a hazard ratio of 0.47 (95% CI: 0.22 to 1.01; p = 0.053). There was no significant difference in the 6-month Oxford Hip Score, the EuroQol-5 Dimension (EQ-5D) and EQ-VAS (Visual Analogue Scale) scores, and patient-reported success rates. Patient satisfaction (single-item satisfaction outcome measure) was higher in the computer-guided group, but this finding was limited by a reduced number of responses. Conclusions In our analysis, the use of computer-guided surgery was associated with a lower rate of revision at mean follow-up of 5.6 years. This finding was upheld when the sample was restricted to cementless-only THAs. Causality cannot be inferred in view of the observational nature of the study, and additional studies are recommended to validate these findings. Level of Evidence Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
20
|
Comparison of Outcomes After Robotic-Assisted or Conventional Total Hip Arthroplasty at a Minimum 2-Year Follow-up: A Systematic Review. JBJS Rev 2021; 9:01874474-202106000-00011. [PMID: 34130305 DOI: 10.2106/jbjs.rvw.20.00144] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
BACKGROUND This systematic review aimed to present an updated analysis of the evidence comparing outcomes between robotic-assisted total hip arthroplasty (robotic THA) and conventional manual total hip arthroplasty (manual THA). METHODS A PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) systematic review was performed using the Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, PubMed, MEDLINE, and Embase. Controlled studies comparing primary robotic THA and manual THA utilizing patient-reported outcome measures (PROMs) at a minimum follow-up of 2 years were included. We also compared radiographic outcomes, dislocation rates, and revision surgical procedures between groups. The ROBINS-I (Risk of Bias in Non-Randomized Studies - of Interventions) and Cochrane Risk of Bias 2.0 tools were used to assess study quality and risk of bias. RESULTS Of 765 studies identified, 7 articles comparing robotic THA with manual THA met inclusion criteria. A total of 658 patients were assessed, 335 of whom underwent robotic THA. The majority of studies found no significant differences (p > 0.05) in PROMs between the 2 techniques. Two low-quality studies (Level III) found significantly better postoperative PROMs favoring robotic THA at 2 years. When assessing radiographic outcomes, 6 studies showed that robotic THA resulted in more consistent and accurate component placement. No differences in postoperative dislocations, complications, or revision rates were found between groups except in 1 study, which found significantly more dislocations and revisions in the robotic THA cohort. Reported operative times were a mean of 12 to 25 minutes longer when using robotic THA. CONCLUSIONS The existing literature comparing robotic THA and manual THA is scarce and low-quality, with findings limited by methodological flaws in study design. Although evidence exists to support increased accuracy and reproducibility of THA component placement with robotic THA, this has not been shown to reduce postoperative dislocation and revision rates. Based on the available evidence, functional outcomes are comparable between techniques, and robotic THA appears to be associated with longer operative times. To fully evaluate the utility of robotic THA, additional well-designed, prospective controlled studies with continuous long-term monitoring are required. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
21
|
Comparison of Cup Setting Angle Accuracy between Computed Tomography-Based and Computed Tomography-Free Navigation in the Same Patients with Crowe's Classification I or II Hip Dysplasia. Clin Orthop Surg 2021; 13:144-151. [PMID: 34094004 PMCID: PMC8173244 DOI: 10.4055/cios20145] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 09/28/2020] [Accepted: 11/25/2020] [Indexed: 12/21/2022] Open
Abstract
Backgroud In total hip arthroplasty, the cup setting angle may affect the postoperative results. In recent years, both computed tomography-based navigation and computed tomography-free (imageless) navigation have been reported to produce high accuracy in cup installation; however, no direct comparison between these two methods has been performed. The present study aimed to directly compare the cup installation angle accuracy between computed tomography-based navigation and computed tomography-free navigation in patients with Crowe's classification stage I or II dysplastic osteoarthritis and to examine the factors affecting the cup installation accuracy. Methods Using both navigation systems for the same technique, primary total hip arthroplasty was performed by the same surgeon in 36 patients. A cup was installed using computed tomography-based navigation, and the installed cup was measured again using computed tomography-free navigation. We compared the error between the target angle and the intraoperative installation angle for each navigation method by performing statistical analyses. Results For computed tomography-based navigation, errors in the inclination and the anteversion angles compared to the target angle were 3.14° ± 1.55° and 1.47° ± 0.99°, respectively. For computed tomography-free navigation, the inclination and anteversion angle errors were significantly larger, i.e., 6.84° ± 4.78° and 5.43° ± 5.22°, respectively (p < 0.01). The inclination and anteversion angles of computed tomography-free navigation were correlated, and there were no significant factors influencing the error. Conclusions Computed tomography-based navigation is more accurate for cup installation than computed tomography-free navigation. When using computed tomography-free navigation, it is necessary to add technical schemes before and during surgery to improve the cup installation accuracy.
Collapse
|
22
|
Abstract
Total hip arthroplasty dislocations that occur inside Lewinnek's anatomical safe zone represent a need to better understand the hip-spine relationship. Unfortunately, the use of obtuse and redundant terminology to describe the hip-spine relationship has made it a relatively inaccessible topic in orthopaedics. However, with a few basic definitions and principles, the hip-spine relationship can be simplified and understood to prevent unnecessary dislocations following total hip arthroplasty.In the following text, we use common language to define a normal and abnormal hip-spine relationship, present an algorithm for recognising and treating a high-risk hip-spine patient, and discuss several common, high-risk hip-spine pathologies to apply these concepts. Simply, high-risk hip-spine patients often require subtle adjustments to acetabular anteversion based on radiographic evaluations and should also be considered for a high-offset stem, dual-mobility articulation, or large femoral head for additional protection against instability and dislocation.
Collapse
|
23
|
Patient-specific total hip arthroplasty is superior to conventional methods for Crowe III and IV adult developmental hip dysplasia: a randomized controlled trial. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:212. [PMID: 33708839 PMCID: PMC7940928 DOI: 10.21037/atm-20-3488] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Background Restoration of the acetabulum during total hip arthroplasty in adults with developmental dysplasia of the hip (DDH-THA) and resumption of hip function remain major challenges. Herein, a new patient-specific instrument (PSI) was developed that uses the superolateral rim of the acetabulum as a positioning marker to assist surgeons in adult DDH-THA. Methods From January 2017 to October 2018, 104 adult DDH patients were randomized to either the PSI group or conventional operation (CO) group, and further divided into eight subgroups by stratified random sampling using Crowe's classification. Complications, Harris hip scores (HHS), and X-ray results were recorded at 3 and 12 months after surgery. Results With the exception of anteversion in CO-Crowe II group patients, there was no difference in the accuracy of cup placement and orientation between the PSI and CO groups in Crowe I and II DDH patients. With the exception of percentage of acetabular cup coverage (PACC) and the qualification rate of Crowe IV PACC patients, among all Crowe III and IV DDH groups, all postoperative indexes of cup orientation and positioning exhibited significant differences between the PSI and CO groups; however, no significant differences were observed in Crowe I and II DDH patients. Conclusions Compared with conventional methods, the new PSI-assisted surgical method improved the accuracy of placement and orientation of the acetabulum and cup prosthesis, optimized the surgical process, reduced complications, and contributed to quicker recovery of hip function after surgery in adults with Crowe III and IV DDH-THA, but little difference was noted for those with Crowe I and II DDH.
Collapse
|
24
|
Computer-Assisted Orthopedic and Trauma Surgery. DEUTSCHES ARZTEBLATT INTERNATIONAL 2020; 117:793-800. [PMID: 33549155 PMCID: PMC7947640 DOI: 10.3238/arztebl.2020.0793] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 04/06/2020] [Accepted: 08/24/2020] [Indexed: 11/27/2022]
Abstract
BACKGROUND There are many ways in which computer-assisted orthopedic and trauma surgery (CAOS) procedures can help surgeons to plan and execute an intervention. METHODS This study is based on data derived from a selective search of the literature in the PubMed database, supported by a Google Scholar search. RESULTS For most applications the evidence is weak. In no sector did the use of computer-assisted surgery yield any relevant clinical or functional improvement. In trauma surgery, 3D-navigated sacroiliac screw fixation has become clinically established for the treatment of pelvic fractures. One randomized controlled trial showed a reduction in the rate of screw misplacement: 0% with 3D navigation versus 20.4% with the conventional procedure und 16.6% with 2D navigation. Moreover, navigation-assisted pedicle screw stabilization lowers the misplacement rate. In joint replacements, the long-term results showed no difference in respect of clinical/functional scores, the time for which the implant remained in place, or aseptic loosening. CONCLUSION Computer-assisted procedures can improve the precision of certain surgical interventions. Particularly in joint replacement and spinal surgery, the research is moving away from navigation in the direction of robotic procedures. Future studies should place greater emphasis on clinical and functional results.
Collapse
|
25
|
Adult Measures of General Health and Health‐Related Quality of Life. Arthritis Care Res (Hoboken) 2020; 72 Suppl 10:522-564. [DOI: 10.1002/acr.24216] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 04/07/2020] [Indexed: 12/15/2022]
|
26
|
WITHDRAWN: Comparison of the accuracy between imageless navigation and manual freehand approaches for total hip arthroplasty: a systematic review and meta-analysis. Chin J Traumatol 2020:S1008-1275(20)30180-2. [PMID: 33008740 DOI: 10.1016/j.cjtee.2020.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 04/07/2020] [Accepted: 06/06/2020] [Indexed: 02/04/2023] Open
Abstract
This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/our-business/policies/article-withdrawal.
Collapse
|
27
|
[Hip-spine syndrome-current developments and state of the evidence]. DER ORTHOPADE 2020; 49:841-848. [PMID: 32857167 DOI: 10.1007/s00132-020-03972-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The movements between the spine, pelvis and hip joints are coordinated to allow for a physiological balance of the upper body and the pelvis during sitting and standing. Degenerative changes or spondylodesis of the spine result in decreased pelvic mobility and can lead to increased rates of instability in the presence of total hip arthroplasty (THA). To reduce the risk of THA dislocation several authors have recently recommended functional radiographs of the spine and pelvis, as well as individual safe zones for THA components. The aim of this article is to summarize the current body of knowledge regarding the influence of spinopelvic alignment on THA and provide recommendations for everyday clinical practice.
Collapse
|
28
|
CORR Insights®: The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components. Clin Orthop Relat Res 2020; 478:1919-1921. [PMID: 32732576 PMCID: PMC7371076 DOI: 10.1097/corr.0000000000001299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 04/22/2020] [Indexed: 01/31/2023]
|
29
|
Augmented Reality for Acetabular Component Placement in Direct Anterior Total Hip Arthroplasty. J Arthroplasty 2020; 35:1636-1641.e3. [PMID: 32063415 DOI: 10.1016/j.arth.2020.01.025] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 12/20/2019] [Accepted: 01/10/2020] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Malposition of the acetabular component of a hip prosthesis can lead to poor outcomes. Traditional placement with fluoroscopic guidance results in a 35% malpositioning rate. We compared the (1) accuracy and precision of component placement, (2) procedure time, (3) radiation dose, and (4) usability of a novel 3-dimensional augmented reality (AR) guidance system vs standard fluoroscopic guidance for acetabular component placement. METHODS We simulated component placement using a radiopaque foam pelvis. Cone-beam computed tomographic data and optical data from a red-green-blue-depth camera were coregistered to create the AR environment. Eight orthopedic surgery trainees completed component placement using both methods. We measured component position (inclination, anteversion), procedure time, radiation dose, and usability (System Usability Scale score, Surgical Task Load Index value). Alpha = .05. RESULTS Compared with fluoroscopic technique, AR technique was significantly more accurate for achieving target inclination (P = .01) and anteversion (P = .02) and more precise for achieving target anteversion (P < .01). AR technique was faster (mean ± standard deviation, 1.8 ± 0.25 vs 3.9 ± 1.6 minute; P < .01), and participants rated it as significantly easier to use according to both scales (P < .05). Radiation dose was not significantly different between techniques (P = .48). CONCLUSION A novel 3-dimensional AR guidance system produced more accurate inclination and anteversion and more precise anteversion in the placement of the acetabular component of a hip prosthesis. AR guidance was faster and easier to use than standard fluoroscopic guidance and did not involve greater radiation dose.
Collapse
|
30
|
Total Hip Arthroplasty Using Imageless Computer-Assisted Navigation-2-Year Follow-Up of a Prospective Randomized Study. J Clin Med 2020; 9:jcm9061620. [PMID: 32471214 PMCID: PMC7355989 DOI: 10.3390/jcm9061620] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 05/12/2020] [Accepted: 05/20/2020] [Indexed: 02/06/2023] Open
Abstract
The purpose of this study is to compare computer-assisted to manual implantation-techniques in total hip arthroplasty (THA) and to find out if the computer-assisted surgery is able to improve the clinical and functional results and reduce the dislocation rate in short-terms after THA. We performed a concise minimum 2-year follow-up of the patient cohort of a prospective randomized study published in 2014 and evaluated if the higher implantation accuracy in the navigated group can be seen as an important determinant of success in total hip arthroplasty. Although a significant difference was found in mean postoperative acetabular component anteversion and in the outliers regarding inclination and anteversion (p < 0.05) between the computer-assisted and the manual-placed group, we could not find significant differences regarding clinical outcome or revision rates at 2-years follow-up. The implantation accuracy in the navigated group can be regarded as an important determinant of success in THA, although no significant differences in clinical outcome could be detected at short-term follow-up. Therefore, further long-term follow-up of our patient group is needed.
Collapse
|
31
|
Effect of patient-specific instrument on lowering threshold for junior physicians to perform total hip arthroplasty on developmental dysplasia of the hip patients. INTERNATIONAL ORTHOPAEDICS 2020; 44:1281-1286. [PMID: 32405884 DOI: 10.1007/s00264-020-04599-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Accepted: 04/27/2020] [Indexed: 01/11/2023]
Abstract
PURPOSE To create a patient-specific instrument (PSI) in lowering the surgical experience requirement for junior physicians to perform total hip arthroplasty (THA) on developmental dysplasia of the hip (DDH) patients. METHODS Combined with rapid prototyping technology, we created a PSI and established DDH hip model in vitro. We enrolled 48 junior physicians and randomly assigned them into two groups. After creation of the PSI, they performed simulated THA surgery on a full-scale hip model with or without PSI on DDH models. The planned prothesis orientation, post-operative prothesis orientation, and surgery time were recorded. RESULTS The final cup inclination was 42.0 ± 0.8° in PSI group and 37.8 ± 2.0° in control group, while final cup anteversion was 16.0 ± 0.7° in PSI group and 24.7 ± 3.5° in control group. The △inclination in PSI group was smaller than that in control group (4.2 ± 0.5° vs 9.5 ± 1.4°, P < 0.01), so does △inclination (2.9 ± 0.4° in PSI group vs 15.2 ± 2.5° in control group, P < 0.01). The outlier percent was 8.3% in PSI group and 70.8% in control group (P < 0.01). At the same time, the PSI group did not prolong the operation time (P = 0.551). CONCLUSION The PSI can greatly increase the accuracy of placing the cup orientation and lower the threshold for junior physicians to perform THA on DDH patients. It could be a training tool for them to increase their THA surgical skills.
Collapse
|
32
|
CORR Insights®: Does An Augmented Reality-based Portable Navigation System Improve the Accuracy of Acetabular Component Orientation During THA? A Randomized Controlled Trial. Clin Orthop Relat Res 2020; 478:944-946. [PMID: 32068550 PMCID: PMC7170701 DOI: 10.1097/corr.0000000000001174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
33
|
|
34
|
Trends and patient factors associated with technology-assisted total hip arthroplasty in the United States from 2005 to 2014. Arthroplast Today 2020; 6:112-117.e1. [PMID: 32211486 PMCID: PMC7083725 DOI: 10.1016/j.artd.2019.12.009] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 12/07/2019] [Accepted: 12/27/2019] [Indexed: 01/14/2023] Open
Abstract
Background Technology-assisted total hip arthroplasty (TA-THA) using either computer-assisted navigation or robotic assistance has become increasingly more popular. The purpose of this study was to examine the trends and patient factors associated with TA-THA. Methods This is a retrospective review utilizing the National Inpatient Sample, a large national database incorporating inpatient hospitalization information. International Classification of Diseases, 9th Revision codes were used to identify patients with hip osteoarthritis who underwent primary total hip arthroplasty (THA). Patients were then separated into those who underwent TA-THA or conventional THA. Outcomes of interest included annual TA-THA utilization; patient and hospital characteristics associated with TA-THA; and trends for length of stay (LOS), cost, and discharge to home. Results From 2005 to 2014, a total of 2,588,304 patients with hip osteoarthritis who underwent THA were identified in the National Inpatient Sample database. Of those, 39,700 (1.5%) underwent TA-THA. The number of TA-THA procedures increased from 178 (0.1% of all THA) in 2005 to 10,045 (3.0% of all THA) in 2014, which represented a 30-fold increase in incidence (P-trend <.0001). TA-THA was associated with Hispanic race, higher patient income, and the Western region of the United States. During the study period, there was a trend toward decreased LOS and increased discharge to home for both TA-THA and conventional THA. TA-THA was associated with higher inpatient cost. Conclusion TA-THA is being increasingly used in the United States and is associated with specific patient factors. However, the value of TA-THA compared to conventional THA remains unclear and should be assessed with future research. Level of Evidence III (retrospective cohort study).
Collapse
|
35
|
Computerized navigation for total hip arthroplasty is associated with lower complications and ninety-day readmissions: a nationwide linked analysis. INTERNATIONAL ORTHOPAEDICS 2020; 44:471-476. [PMID: 31919568 DOI: 10.1007/s00264-019-04475-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Accepted: 12/23/2019] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The objective was to evaluate if the use of CA-THA was associated with lower complications in the first 90 days following THA compared with conventional THA. METHODS The Nationwide Readmission Database (NRD) was queried to identify patients who underwent THA between 2012 and 2014. The primary outcome was arthroplasty-related complications within the first 90 days following THA. Multivariate models predicting the risk of complications, readmission, and revision-related readmission within 90 days of discharge were created. RESULTS A total of 309,252 patients with a minimum 90-day follow-up following elective primary THA were identified. After controlling for age, sex, comorbidities, indication, income, and type of insurance, the use of CA during THA resulted in a 12% reduced odds of 90-day complications (OR 0.88, 95% CI 0.77-0.99, p = 0.04). DISCUSSION The use of CA-THA resulted in lower 90-day complication rates and readmission rates compared with traditional THA after controlling for confounding variables. There was no significant difference in the rates of revision surgery between the groups within the first 90 days.
Collapse
|
36
|
The Accuracy of the Computed Tomography-Based Navigation System in Total Hip Arthroplasty Is Comparable With Crowe Type IV and Crowe Type I Dysplasia: A Case-Control Study. J Arthroplasty 2019; 34:2686-2691. [PMID: 31256919 DOI: 10.1016/j.arth.2019.06.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 05/27/2019] [Accepted: 06/03/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Clinical outcomes of total hip arthroplasty (THA) for Crowe type IV are poorer than for Crowe type I, because it is more difficult to accurately position the acetabular components. This study aimed to examine the accuracy of the computed tomography (CT)-based navigation system for acetabular component positioning in primary THA for Crowe type IV. METHODS From 2006 to 2018, 29 patients who underwent 34 primary THAs for Crowe type IV were enrolled in the "Type IV" group and 32 patients who underwent 34 THAs for Crowe type I were enrolled in the "Type I" group, formed by matching patients in the Type IV group on age, gender, body mass index, and surgical approach. We investigated (1) the accuracy of the cup size between that at preoperative planning and that actually implanted and (2) the mean deviation of the cup angle and 3-dimensional position of acetabular components between preoperative plan and postoperative records. RESULTS The accuracy of the cup size was 79.4% and 94.1% in the Type IV and Type I groups, respectively, without a statistically significant change detected (P = .075). The mean deviations of the cup angle and 3-dimensional position were comparable in both groups. CONCLUSION Using the CT-based navigation system, it was possible to accurately implant the acetabular component for Crowe type IV, and the accuracy was comparable to that for Crowe type I. The CT-based navigation system is a useful intraoperative tool to accurately implant the acetabular component, especially with severe pelvic deformities such as Crowe type IV.
Collapse
|
37
|
Risk factors for dislocation after primary total hip replacement: a systematic review and meta-analysis of 125 studies involving approximately five million hip replacements. THE LANCET. RHEUMATOLOGY 2019; 1:e111-e121. [PMID: 38229338 DOI: 10.1016/s2665-9913(19)30045-1] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 08/15/2019] [Accepted: 08/16/2019] [Indexed: 11/19/2022]
Abstract
BACKGROUND Dislocation following total hip replacement is associated with repeated admissions to hospital and substantial costs to the health system. Factors influencing dislocation following primary total hip replacement are not well understood. We aimed to assess the association of various factors with dislocation risk following primary total hip replacement. METHODS We did a systematic review and meta-analysis of longitudinal studies reporting associations of patient-related, surgery-related, implant-related, and hospital-related factors with dislocation risk after primary total hip replacement. We searched MEDLINE, Embase, Web of Science, and the Cochrane Library for all relevant articles published up to March 8, 2019. Summary measures of association were calculated with relative risks (RRs) and 95% CIs. This study is registered on PROSPERO, number CRD42019121378. FINDINGS We identified 149 articles based on 125 unique studies with data on 4 633 935 primary total hip replacements and 35 264 dislocations. The incidence of dislocation ranged from 0·12% to 16·13%, with an overall pooled incidence of 2·10% (95% CI 1·83-2·38) over a weighted mean follow-up duration of 6 years. Based on the median year of data collection, a significant decline in dislocation rates was observed from 1971 to 2015. The risk of dislocation did not differ significantly between male versus female patients (RR 0·97; 95% CI 0·88-1·08), was higher in those aged 70 years and older than in those younger than 70 years (1·27; 1·02-1·57), and was lower in those from high versus low income groups (0·79; 0·74-0·85). White ethnicity (only when compared with Asian ethnicity), drug use disorder, and social deprivation were significantly associated with increased dislocation risk. The risk of dislocation was higher in patients with body-mass index (BMI) of 30 kg/m2 or higher than in those with BMI lower than 30 kg/m2 (RR 1·38; 95% CI 1·03-1·85). Medical factors and those related to surgical history that were significantly associated with increased dislocation risk included neurological disorder, psychiatric disease, comorbidity indices, previous surgery including spinal fusion, and surgical indications including avascular necrosis, rheumatoid arthritis, inflammatory arthritis, and osteonecrosis. Surgical factors such as the anterolateral, direct anterior, or lateral approach, and posterior approach with short external rotator and capsule repair were significantly associated with reduced dislocation risk. At the implant level, larger femoral head diameters, elevated acetabular liners, dual mobility cups, cemented fixations, and standard femoral neck lengths significantly reduced the risk of dislocation. Hospital-related factors such as experienced surgeons and high surgeon procedure volume significantly reduced the risk of dislocation. INTERPRETATION Dislocation following primary total hip replacement has declined over time. Surgical approaches that reduce dislocation risk can be used by clinicians during primary total hip replacement, and alternative bearings such as dual mobility can be used in individuals at high risk of dislocation. Modifiable risk factors such as high BMI and comorbidities might also be amenable to optimisation before surgery. FUNDING National Institute for Health Research.
Collapse
|
38
|
Modern cup alignment techniques in total hip arthroplasty: A systematic review. Orthop Traumatol Surg Res 2019; 105:907-913. [PMID: 31054840 DOI: 10.1016/j.otsr.2019.03.015] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2018] [Revised: 03/05/2019] [Accepted: 03/14/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION A systematic review was conducted to assess the clinical and radiological outcomes of the alternative surgical techniques that consider the dynamic aspect of the acetabular orientation when aligning a cup (pelvic tilt-, lumbo-pelvic kinematics-, and spine-hip relationship-adjusted cup alignment techniques). METHOD Eight eligible articles reported the outcomes of total hip arthroplasty (THA) performed with alternative techniques. Clinical and radiological data were extracted. One study had a control group of patients who underwent conventional THAs (level III) while the seven other studies were level IV. Computer navigation system (CAS), Optimized Positioning System (OPS™), and manual instrumentation were used to align components in four, two, and two studies, respectively. A meta-analysis was not carried out because there was a lack of homogeneity between included articles regarding the method to position the cup and the nature of the reported data. RESULTS THA performed with alternative techniques had an early dislocation rate ranging from 0 to 1.9%, no unexpected catastrophic failure, and acceptable radiographic cup orientations. One study compared kinematically and mechanically aligned THAs and found no dislocation in either groups, similar patient reported outcome measures (43 Oxford-12 Score for both groups), and similar proportions of cup in the Lewinnek zone (respectively 65% and 70%). DISCUSSION/CONCLUSION Alternative methods accounting for the functional acetabular orientation seem to be clinically safe and effective in the early-term, and generate acceptable cup orientation on radiographs. Their values compare to those of more conventional techniques for cup implantation remain to be determined. We developed a classification of the multiple methods for aligning an acetabular component. LEVEL OF EVIDENCE IV, systematic review of level III and IV studies.
Collapse
|
39
|
A novel positioner for accurately sitting the acetabular component: a retrospective comparative study. J Orthop Surg Res 2019; 14:279. [PMID: 31462276 PMCID: PMC6714239 DOI: 10.1186/s13018-019-1331-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Accepted: 08/19/2019] [Indexed: 02/02/2023] Open
Abstract
Introduction In this study, we described a positioner which allows a combination of preoperative plan and intraoperative insertion of the cup to improve the reconstruction of the rotation center of the hip. Materials and methods A retrospective study was conducted on 32 consecutive patients (group A) using this positioner and 40 consecutive patients (group B) using conventional method; radiological parameters and clinical measurements before operation and at last follow-up were collected and evaluated. Results Group A had a reconstructed center of rotation (COR) that was 0.19 mm closer to the anatomic COR in height (P < 0.005), compared with group B with 3.45 mm vertical dislocation. There were no statistically significant differences in the horizontal displacement between the two groups. The accuracy of cup inclination was 42.14 ± 3.57 in the group A and 38.73 ± 7.65 in the group B (P = 0.015). The accuracy of cup anteversion was 14.82 ± 1.44 in the group A and 13.08 ± 5.95 in the group B (P = 0.082). All cups in the group A were radiologically stable, while one cup in the group B was radiologically unstable and was successfully treated with second-stage revision. Both of the groups obtained a higher mean postoperative Harris Hip Score. Conclusions Utilizing this positioner helps to restore the COR position more precisely and provides satisfactory radiological and clinical outcomes in the short term, and more studies are required before its widespread adoption for complicated cases.
Collapse
|
40
|
|
41
|
An Open-Label, Single-Arm Study of a Patient-Specific Femoral Guide for Total Hip Arthroplasty via the Anterolateral Supine Approach, Linked with Three-Dimensional Surgical Support Software: Study Protocol. Kurume Med J 2019; 65:71-75. [PMID: 30197407 DOI: 10.2739/kurumemedj.ms652002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
In total hip arthroplasty (THA), it is generally accepted that the bones of the acetabular cup and femur of hip joint must be accurately cut and components (artificial joint parts) be implanted in exact positions at exact angles to achieve improvement of daily living (ADL) and quality of life (QOL). However, with the conventional surgical method, it is difficult to grasp and measure the acetabular cup and femoral stem precisely during surgery, making some kind of reliable guide necessary. Although it was reported that an accurate angle was achieved in acetabular cup implantation by support instruments for surgical planning, an effective support instrument is now being developed for stem implantation on the out-of-reach femur side. This is the first clinical study to assess the efficacy and safety of anterolateral approach THA using an extracorporeal patient-specific femoral guide (PSG) for stem implantation with three-dimensional (3D) surgical support software in patients with hip joint disease.
Collapse
|
42
|
From Bench to Bedside: Robotics and Navigation in Orthopaedics-Rise of the Machines or Just Rising Costs? Clin Orthop Relat Res 2019; 477:692-694. [PMID: 30844827 PMCID: PMC6437387 DOI: 10.1097/corr.0000000000000668] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
43
|
Computer-Assisted Navigation Is Associated with Reductions in the Rates of Dislocation and Acetabular Component Revision Following Primary Total Hip Arthroplasty. J Bone Joint Surg Am 2019; 101:250-256. [PMID: 30730484 DOI: 10.2106/jbjs.18.00108] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Prior work suggests that computer-assisted navigation improves acetabular component position during primary total hip arthroplasty (THA). However, it is not known whether this translates to improvements in clinical outcomes. The purpose of this study was to test for associations between navigation use and the risk of dislocation, aseptic revision of the acetabular component, aseptic revision of the femoral component, aseptic revision of either component, and acute periprosthetic joint infection (PJI). METHODS This was a retrospective cohort study, conducted using the 100% Medicare Part A claims data set. Inclusion criteria were an age of ≥65 years and primary THA for osteoarthritis. First, the association between navigation use and patient and hospital characteristics was assessed. Second, while controlling for these characteristics, multivariate regression was used to test for the association of navigation use and the outcomes listed above. RESULTS A total of 803,732 primary THA procedures were identified; 14,540 (1.81%) involved the use of navigation. Navigation use was associated with younger age, other/unknown race, the Western census region, higher socioeconomic status, lower Charlson Comorbidity Index, shorter length of stay, private hospitals, teaching hospitals, and larger hospitals (p < 0.05 for each). Navigation use was associated with a lower rate of dislocation (1.00% versus 1.70% for no navigation; adjusted hazard ratio [HR] = 0.69; 95% confidence interval [CI] = 0.58 to 0.82; p < 0.001) and aseptic revision of the acetabular component (1.03% versus 1.55%; adjusted HR = 0.75; 95% CI = 0.64 to 0.88; p < 0.001). Navigation was not associated with aseptic revision of the femoral component (1.54% versus 1.87%; p = 0.064), aseptic revision of either component (1.91% versus 2.31%; p = 0.077), acute PJI at 6 weeks (0.34% versus 0.45%; p = 0.121), or acute PJI at 90 days (0.50% versus 0.66%; p = 0.458). CONCLUSIONS The findings of this study suggest that navigation is associated with reductions in the rates of dislocation and aseptic acetabular revision following primary THA. However, these results should be interpreted carefully in the setting of potential confounding by unmeasured variables, such as surgeon volume, family support, and patient compliance. Causality cannot be inferred until further prospective trials can vet this technology. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
|
44
|
Accuracy and practicability of a patient-specific guide using acetabular superolateral rim during THA in Crowe II/III DDH patients: a retrospective study. J Orthop Surg Res 2019; 14:19. [PMID: 30642333 PMCID: PMC6332857 DOI: 10.1186/s13018-018-1029-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 12/04/2018] [Indexed: 01/27/2023] Open
Abstract
Background It is challenging to create an ideal artificial acetabulum during total hip arthroplasty (THA) in adult DDH. Our team developed a new patient-specific instrument (PSI) that uses the superolateral rim of the acetabulum as a positioning mark to assist in the production of an artificial acetabulum in adult Crowe II/III DDH patients. The purpose of this retrospective study is to verify whether this new PSI can be used to implement the preoperative plan accurately and quickly to create an ideal artificial acetabulum during THA in adult Crowe II/III DDH patients. Methods We selected suitable adult Crowe II/III DDH patients from the registration system for artificial joint surgery at our hospital during April 2016 to March 2018 who underwent THA assisted by a PSI using the superolateral rim of the acetabulum as a positioning mark. We retrospectively analyzed data, including preoperative and postoperative anteversion, inclination, postoperative bilateral rotator center discrepancy (BRCD), surgery time, and the incidence of neurovascular injury. All patients underwent follow-up, and their Harris hip score (HHS) and X-ray data were recorded. Then, we performed statistical analyses on the data described above. Results A total of 20 hip surgeries from 17 patients were included in our study. All patients underwent a successful operation assisted by the PSI. The mean anteversion of the cup in our preoperative plan was 15.1° (range, 10.0° to 20.0°), while the mean postoperative anteversion of the cup was 15.3° (range, 7.0° to 28.6°). The mean inclination of the cup in our preoperative plan was 44.7° (range, 40.0° to 50.0°), while the mean postoperative inclination of the cup was 45.6° (range, 35.0° to 57.6°). Paired-samples t test revealed no significant differences in anteversion and inclination between pre- and postoperation times (P > 0.05). The mean BRCD was 3.38 ± 3.0 mm (range, 0.5 to 11.0 mm). The average operation time was 105.1 ± 15.4 min, and no patients had neurovascular injury complications. All patients’ acetabular components appeared clinically and radiologically stable after surgery. The mean HHS values were significantly improved at 12 weeks (P < 0.05) and 24 weeks (P < 0.05) postoperatively compared to the preoperative mean scores. Conclusions The new PSI is accurate and practical to create an ideal artificial acetabulum during THA in adult Crowe II/III DDH patients. Electronic supplementary material The online version of this article (10.1186/s13018-018-1029-1) contains supplementary material, which is available to authorized users.
Collapse
|
45
|
Guided Pelvic Resections in Tumor Surgery. Tech Orthop 2018. [DOI: 10.1097/bto.0000000000000299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
46
|
Is anatomic acetabular orientation related to pelvic morphology? CT analysis of 150 healthy pelvises. Orthop Traumatol Surg Res 2018; 104:347-351. [PMID: 29122687 DOI: 10.1016/j.otsr.2017.10.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 10/04/2017] [Accepted: 10/31/2017] [Indexed: 02/02/2023]
Abstract
BACKGROUND Links between sagittal spinal alignment and acetabular orientation attract considerable research attention with the goal of optimising prosthetic cup position. However, whether pelvic incidence (PI) is related to anatomic acetabular orientation remains unknown. We therefore conducted a radiological study with the following objectives: to look for correlations between PI and anatomic acetabular parameters; to describe the sacro-pubic angle (SPA), defined by fixed bony pelvic landmarks, and its relations with acetabular anteversion; and to determine whether anatomical parameters (PI and SPA) correlate with demographic characteristics. HYPOTHESIS PI correlates with anatomical acetabular parameters. MATERIALS AND METHODS We conducted a computed tomography (CT) study of the pelvises of 150 patients free of degenerative disease. Three parameters were measured: anatomic acetabular orientation in the Lewinnek reference plane, PI, and the SPA subtended by the line connecting the midpoint of the sacral endplate to the pubic symphysis and the anterior pelvic plane. Statistical tests were performed to look for correlations among these parameters. RESULTS Intra-observer and inter-observer reproducibility was considered highly satisfactory (inter-class correlation coefficient, >86% and >82%, respectively). Mean PI was 58.6°±10.2° (range, 32.8°-97.6°), with no significant differences between genders or across age groups. Mean SPA was 34.7°±5.5° (range, 18.3°-49.8°). Mean anatomic acetabular anteversion (AAA) was greater in females (23.4°; range, 11.5°-34.5°) than in males (20°; range, 7.5°-34.5°) (P<0.001). PI did not correlate with any of the acetabular parameters (PI/AAA, r=0.8 and P=0.33; PI/acetabular inclination on the horizontal, r=-0.96 and P=0.24). SPA correlated significantly with both PI (r=0.33 and P<0.001) and AAA (r=0.33 and P<0.001). DISCUSSION This CT study of normal pelvises showed that AAA was significantly greater in females and that SPA correlated significantly with both PI and acetabular anteversion. SPA could serve to define the "theoretical" AAA of each individual patient and could thus be incorporated into surgical planning protocols or intra-operative guidance methods for hip replacement surgery. LEVEL OF EVIDENCE IV, retrospective study with no control group.
Collapse
|
47
|
Risk Factors for Early Dislocation Following Primary Elective Total Hip Arthroplasty. J Arthroplasty 2018; 33:1567-1571.e2. [PMID: 29395718 DOI: 10.1016/j.arth.2017.12.034] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 12/12/2017] [Accepted: 12/14/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Dislocation following total hip arthroplasty (THA) continues to be one of the most common reasons for revision THA. The purpose of this study is to measure the current rate of dislocation following THA in the United States. A secondary goal is to identify patients at highest risk of instability after THA. METHODS The Nationwide Readmissions Database was used to identify cases of elective primary THA between 2012 and 2014. All readmissions associated with dislocations were identified. Kaplan-Meier curves were used to assess the time to dislocation in the study population. A multivariate logistic regression was modeled to assess risk factors associated with readmission for dislocation. RESULTS A total of 207,285 THAs were identified between 2012 and 2014. Of the total, 2842 dislocation-associated readmissions (1.4%) were identified, at a median of 40 days post-THA. A history of spinal fusion was the strongest independent predictor of dislocation (odds ratio [OR], 2.45; 95% confidence interval [CI], 1.97-3.04; P < .0001). Parkinson's disease was also significantly associated with dislocation (OR, 1.63; 95% CI, 1.05-2.51; P = .03), as well as dementia (OR, 1.96; 95% CI, 1.13-3.39; P = .02), depression (OR, 1.28; 95% CI, 1.13-1.43; P < .0001), and chronic lung disease (OR, 1.2; 95% CI, 1.07-1.33; P = .001). Inflammatory arthritis and avascular necrosis were independent risk factors for dislocation (OR, 1.56; 95% CI, 1.25-1.97; P < .0001; OR, 1.67; 95% CI, 1.45-1.93; P < .0001). CONCLUSION THA is a highly effective procedure with a low overall rate of instability. A history of spinal fusion was the most significant independent risk factor for dislocation within the first 6 months following THA.
Collapse
|
48
|
Internet Promotion of Direct Anterior Approach Total Hip Arthroplasty by Members of the American Association of Hip and Knee Surgeons. J Arthroplasty 2018; 33:167-170.e1. [PMID: 29066111 DOI: 10.1016/j.arth.2017.08.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 07/27/2017] [Accepted: 08/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The direct anterior approach (DAA) in total hip arthroplasty is of significant interest to both patients and surgeons, largely due to intense marketing. This study addressed the question, "What is the level of promotion of DAA total hip arthroplasty on the internet by American Association of Hip and Knee Surgeons (AAHKS) members?" METHODS An internet search was performed to identify surgeon-specific websites for each member of the AAHKS using the members' full name and a previously published set of criteria. Each website was evaluated utilizing a questionnaire to systematically identify claims made regarding proposed DAA-specific risks, benefits, as well as the presence/absence of supporting data. RESULTS We identified 1855 qualified websites. The DAA was referenced on 22.8% (423/1855) of these websites. Claims regarding DAA-specific benefits included less invasive/muscle sparing (46.3%), quicker recovery (45.2%), decreased pain (28.1%), decreased hospital stay (22.0%), and decreased dislocation risk (16.3%). Potential DAA risks including lateral femoral cutaneous nerve injury, periprosthetic/greater trochanteric fracture, and wound complication/hematoma were addressed on only 4.7%, 3.1%, and 1.7% of websites, respectively. Supporting peer-reviewed literature was identified on only 3.6% of DAA websites. CONCLUSION Over one-fifth of AAHKS members promoted the DAA on the internet. Member websites claimed DAA benefits such as faster recovery and decreased pain approximately 9 times more frequently than any potential risk of the procedure (P < .001). While AAHKS policy does not regulate member marketing, it is the responsibility of all orthopedic surgeons to disseminate accurate, validated information concerning the procedures we perform.
Collapse
|
49
|
Abstract
The goal of this review paper is to retrieve from the existing literature relevant information (1) about the learning curve of the currently existing navigation systems and (2) about the use of navigation system for teaching orthopaedic procedures. All studies reporting on the learning curve of navigation systems support the hypothesis that computer-navigated total knee arthroplasty (TKA) involves only a short learning curve and that beginners can obtain good results from the beginning of their experience, as navigation provides continuous feedback during all phases of the knee replacement surgery and allows for correcting any bone cut errors. Interestingly, there is no comparable research on the learning curve of TKA with standard, manual instrumentation. One might postulate that this learning curve might be longer than with navigation, with potentially a higher rate of outliers. The current literature does support that navigation may be an efficient teaching tool for both experienced orthopaedic surgeons and trainees. Experienced surgeons may improve their skills with conventional techniques and learn new techniques more efficiently and more quickly. Trainees may have a better understanding of the procedure and learn standard techniques with a shorter learning curve. This is probably due to the immediate feedback of navigation systems. A shorter learning curve may be associated with improved clinical and functional results for the patient during this critical period. However, there is no evidence that training with navigation excludes trainees from the need to work in academic environments with experienced teachers. Future techniques in training may include the development of laboratory simulation procedures using navigated feedback.
Collapse
|
50
|
Management of recurrent dislocation after total hip arthroplasty. CURRENT ORTHOPAEDIC PRACTICE 2017. [DOI: 10.1097/bco.0000000000000507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|