1
|
Guo D, Qi J, Du Y, Zhao C, Liu S, Lu Y, Zhu X. Tear inflammatory cytokines as potential biomarkers for myopic macular degeneration. Exp Eye Res 2023; 235:109648. [PMID: 37704045 DOI: 10.1016/j.exer.2023.109648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2023] [Revised: 08/26/2023] [Accepted: 09/10/2023] [Indexed: 09/15/2023]
Abstract
Previous studies have reported that inflammatory cytokine levels increase in the intraocular fluids (aqueous humor and vitreous) of highly myopic eyes, However, there has been currently no study revealing the levels of inflammatory cytokines in tear. Therefore, this study aimed to determine tear cytokine levels of highly myopic eyes, and their relationships with myopic macular degeneration (MMD). This case-control study screened inflammatory cytokines of tear samples from 132 highly myopic and 105 emmetropic eyes using a multiplex cytokine antibody array, and cytokines showing significant intergroup differences were further validated using ProQuantum immunoassays in tear samples from another 60 highly myopic and 60 emmetropic eyes. Ultra-widefield fundus photographs of eyes were classified according to the meta-analyses of the Pathologic Myopia Classification. Associations between tear cytokine levels and MMD category were investigated. As a result, tear levels of interleukin (IL)-6, IL-13 and monocyte chemoattractant protein (MCP)-1 were screened significantly higher in highly myopic eyes than in emmetropic controls (IL-6: 11.70 ± 16.81 versus 8.22 ± 10.76 pg/mL; MCP-1: 63.60 ± 54.40 versus 33.87 ± 43.82 pg/mL; both P < 0.05). Validation assays further demonstrated the elevated concentrations of IL-6 and MCP-1 (IL-6: 13.97 ± 8.41 versus 8.06 ± 7.94 pg/mL, P < 0.001; MCP-1: 32.69 ± 8.41 versus 18.07 ± 8.41 pg/mL, P = 0.003). Tear levels of IL-6 and MCP-1 differed significantly among MMD categories (both P < 0.05). The area under receiver operating characteristic curve were 0.783 and 0.682 respectively (both P < 0.05), when using tear IL-6 and MCP-1 levels to predict the presence of MMD (category ≥2). The ordered logistic regression model also indicated that longer axial length, and higher IL-6 and MCP-1 tear levels were independent predictors of higher MMD category. In our study, highly myopic eyes presented significantly higher levels of tear IL-6 and MCP-1, which may also serve as potential biomarkers for MMD.
Collapse
Affiliation(s)
- Dongling Guo
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China; Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Jiao Qi
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China; Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Yu Du
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China; Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Chen Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
| | - Shuyu Liu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China; Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Yi Lu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China; Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Xiangjia Zhu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Myopia, Fudan University, Shanghai, China; Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, China; Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China.
| |
Collapse
|
2
|
Abstract
![]()
Personalized and
point-of-care (POC) diagnoses are critical for
ocular physiology and disease diagnosis. Real-time monitoring and
continuous sampling abilities of tear fluid and user-friendliness
have become the key characteristics for the applied ophthalmic techniques.
Fluorescence technologies, as one of the most popular methods that
can fulfill the requirements of clinical ophthalmic applications for
optical sensing, have been raised and applied for tear sensing and
diagnostic platforms in recent decades. Wearable sensors in this case
have been increasingly developed for ocular diagnosis. Contact lenses,
as one of the commercialized and popular tools for ocular dysfunction,
have been developed as a platform for fluorescence sensing in tears
diagnostics and real-time monitoring. Numbers of biochemical analytes
have been examined through developed fluorescent contact lens sensors,
including pH values, electrolytes, glucose, and enzymes. These sensors
have been proven for monitoring ocular conditions, enhancing and detecting
medical treatments, and tracking efficiency of related ophthalmic
surgeries at POC settings. This review summarizes the applied ophthalmic
fluorescence sensing technologies in tears for ocular diagnosis and
monitoring. In addition, the cooperation of fabricated fluorescent
sensor with mobile phone readout devices for diagnosing ocular diseases
with specific biomarkers continuously is also discussed. Further perspectives
for the developments and applications of fluorescent ocular sensing
and diagnosing technologies are also provided.
Collapse
Affiliation(s)
- Yuqi Shi
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, United Kingdom
| | - Yubing Hu
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, United Kingdom
| | - Nan Jiang
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu 610041, China
| | - Ali K. Yetisen
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, United Kingdom
| |
Collapse
|
3
|
Biochemistry of human tear film: A review. Exp Eye Res 2022; 220:109101. [DOI: 10.1016/j.exer.2022.109101] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 04/18/2022] [Accepted: 04/26/2022] [Indexed: 12/13/2022]
|
4
|
Elsherif M, Alam F, Salih AE, AlQattan B, Yetisen AK, Butt H. Wearable Bifocal Contact Lens for Continual Glucose Monitoring Integrated with Smartphone Readers. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2021; 17:e2102876. [PMID: 34605152 DOI: 10.1002/smll.202102876] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/22/2021] [Indexed: 06/13/2023]
Abstract
Commercial implantable continuous glucose monitoring devices are invasive and discomfort. Here, a minimally-invasive glucose detection system is developed to provide quantitative glucose measurements continually based on bifocal contact lenses. A glucose-sensitive phenylboronic acid derivative is immobilized in a hydrogel matrix and the surface of the hydrogel is imprinted with a Fresnel lens. The glucose-responsive hydrogel is attached to a commercial soft contact lens to be transformed into a bifocal contact lens. The contact lens showed bifocal lengths; far-field focal length originated from the contact lens' curvature, and near-field focal length resulting from the Fresnel lens. When tear glucose increased, the refractive index and groove depth of the Fresnel lens changed, shifting the near-field focal length and the light focusing efficiency. The recorded optical signals are detected at an identical distance far from the contact lens change. The bifocal contact lens allowed for detecting the tear glucose concentration within the physiological range of healthy individuals and diabetics (0.0-3.3 mm). The contact lens rapidly responded to glucose concentration changes and reached 90% of equilibrium within 40 min. The bifocal contact lens is a wearable diagnostic platform for continual biomarker detection at point-of-care settings.
Collapse
Affiliation(s)
- Mohamed Elsherif
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, 127788, UAE
| | - Fahad Alam
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, 127788, UAE
| | - Ahmed E Salih
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, 127788, UAE
| | - Bader AlQattan
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, 127788, UAE
| | - Ali K Yetisen
- Department of Chemical Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Haider Butt
- Department of Mechanical Engineering, Khalifa University, Abu Dhabi, 127788, UAE
| |
Collapse
|
5
|
Shi Y, Jiang N, Bikkannavar P, Cordeiro MF, Yetisen AK. Ophthalmic sensing technologies for ocular disease diagnostics. Analyst 2021; 146:6416-6444. [PMID: 34591045 DOI: 10.1039/d1an01244d] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Point-of-care diagnosis and personalized treatments are critical in ocular physiology and disease. Continuous sampling of tear fluid for ocular diagnosis is a need for further exploration. Several techniques have been developed for possible ophthalmological applications, from traditional spectroscopies to wearable sensors. Contact lenses are commonly used devices for vision correction, as well as for other therapeutic and cosmetic purposes. They are increasingly being developed into ocular sensors, being used to sense and monitor biochemical analytes in tear fluid, ocular surface temperature, intraocular pressure, and pH value. These sensors have had success in detecting ocular conditions, optimizing pharmaceutical treatments, and tracking treatment efficacy in point-of-care settings. However, there is a paucity of new and effective instrumentation reported in ophthalmology. Hence, this review will summarize the applied ophthalmic technologies for ocular diagnostics and tear monitoring, including both conventional and biosensing technologies. Besides applications of smart readout devices for continuous monitoring, targeted biomarkers are also discussed for the convenience of diagnosis of various ocular diseases. A further discussion is also provided for future aspects and market requirements related to the commercialization of novel types of contact lens sensors.
Collapse
Affiliation(s)
- Yuqi Shi
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| | - Nan Jiang
- West China School of Basic Medical Sciences and Forensic Medicine, Sichuan University, Chengdu 610041, China.
| | | | - M Francesca Cordeiro
- UCL Institute of Ophthalmology, London, UK.,ICORG, Imperial College London, London, UK
| | - Ali K Yetisen
- Department of Chemical Engineering, Imperial College London, South Kensington, London, SW7 2BU, UK.
| |
Collapse
|
6
|
Alotaibi S, Markoulli M, Ozkan J, Papas E. Bio-chemical markers of chronic, non-infectious disease in the human tear film. Clin Exp Optom 2021; 105:166-176. [PMID: 34592130 DOI: 10.1080/08164622.2021.1974282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
The tear film is a thin, moist layer covering the ocular surface and is laden with proteins, peptides, lipids, mucins, electrolytes and cellular debris which function to maintain the healthy status of the ocular surface. In many cases of ocular or systemic disease, the integrity of this layer is changed and/or the balance of its constituents is disturbed. Since tears are easy and quick to collect and can be stored for long periods, they have the potential to be a valuable source of information relevant to many disease states. The purpose of this review is to collate information on the known biomarkers of systemic disease that have been identified in tears. The range of conditions covered includes diabetes mellitus, diabetic retinopathy, diabetic peripheral neuropathy, multiple sclerosis, Parkinson's disease, Alzheimer's disease, migraine, systemic sclerosis, cystic fibrosis, thyroid disorders and cancer.
Collapse
Affiliation(s)
- Sultan Alotaibi
- Department of Optometry & Vision Science, University of New South Wales, Sydney, Australia.,King Saud University, Riyadh, Saudi Arabia
| | - Maria Markoulli
- Department of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Jerome Ozkan
- Department of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| | - Eric Papas
- Department of Optometry & Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
7
|
Gulias-Cañizo R, Ruíz-Leyja ED, Sánchez-Huerta V, Ochoa-de la Paz L. SARS-CoV-2 and the Eye: A Relationship for a Possible Prognostic Tool in COVID-19 Patients. Clin Ophthalmol 2021; 15:707-712. [PMID: 33658751 PMCID: PMC7917349 DOI: 10.2147/opth.s284191] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 12/04/2020] [Indexed: 01/08/2023] Open
Abstract
PURPOSE In December 2019 there was the first report about a new viral infection in Wuhan, China. The new virus was taxonomically designed as Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) causing the coronavirus disease 2019 (COVID-19). SARS-CoV-2 uses the angiotensin-converting enzyme 2 (ACE2) receptor for cell invasion, which is expressed in different tissues including lungs, small intestine, testicles, kidneys, brain, and the eye. The purpose of this article is to review the available information on the relationship of COVID-19 with the eye, as well as evaluating the possible usefulness of ocular diagnostic tests to help in the diagnosis and/or monitoring of patients with this disease. METHODS We performed a retrospective review of relevant articles from November 2019 to April 2020. RESULTS Ocular infection by SARS-CoV-2 is still controversial; nevertheless, the possibility of being a viral reservoir has been suggested, increasing the likelihood of infection. Some reports demonstrated the presence of SARS-CoV-2 in tears, and previously published data suggest a pathological increase of cytokine concentrations in COVID-19 patients; the cytokine release syndrome or cytokine storm contributes to lung and central nervous system damage. The usefulness of tears for the measurement of inflammatory cytokines in various diseases is well known, in particular IL-6, which has been correlated to the severity of COVID-19. CONCLUSION Considering that the IL-6 signaling cascade may be activated in patients with COVID-19, makes it an excellent target for diagnostic and/or monitoring purposes.
Collapse
Affiliation(s)
- Rosario Gulias-Cañizo
- Facultad de Ciencias de la Salud, Universidad Anáhuac México, Huixquilucan, Edo. de México, México
| | - Estela D’Abril Ruíz-Leyja
- Asociación Para Evitar la Ceguera en México I.A.P. Hospital Dr. Luis Sánchez Bulnes, Mexico City, 04020, Mexico
| | - Valeria Sánchez-Huerta
- Asociación Para Evitar la Ceguera en México I.A.P. Hospital Dr. Luis Sánchez Bulnes, Mexico City, 04020, Mexico
| | - Lenin Ochoa-de la Paz
- Asociación Para Evitar la Ceguera en México I.A.P. Hospital Dr. Luis Sánchez Bulnes, Mexico City, 04020, Mexico
- Departamento de Bioquímica, Facultad de Medicina, Universidad Nacional Autónoma de México, Mexico City, 04510, Mexico
| |
Collapse
|
8
|
Moreddu R, Vigolo D, Yetisen AK. Contact Lens Technology: From Fundamentals to Applications. Adv Healthc Mater 2019; 8:e1900368. [PMID: 31183972 DOI: 10.1002/adhm.201900368] [Citation(s) in RCA: 98] [Impact Index Per Article: 19.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Revised: 05/20/2019] [Indexed: 12/29/2022]
Abstract
Contact lenses are ocular prosthetic devices used by over 150 million people worldwide. Primary applications of contact lenses include vision correction, therapeutics, and cosmetics. Contact lens materials have significantly evolved over time to minimize adverse effects associated with contact lens wearing, to maintain a regular corneal metabolism, and to preserve tear film stability. This article encompasses contact lens technology, including materials, chemical and physical properties, manufacturing processes, microbial contamination, and ocular complications. The function and the composition of the tear fluid are discussed to assess its potential as a diagnostic media. The regulatory standards of contact lens devices with regard to biocompatibility and contact lens market are presented. Future prospects in contact lens technology are evaluated, with particular interest given to theranostic applications for in situ continuous monitoring the ocular physiology.
Collapse
Affiliation(s)
- Rosalia Moreddu
- Department of Chemical EngineeringImperial College London SW7 2AZ London UK
- School of Chemical EngineeringUniversity of Birmingham B15 2TT Birmingham UK
| | - Daniele Vigolo
- School of Chemical EngineeringUniversity of Birmingham B15 2TT Birmingham UK
| | - Ali K. Yetisen
- Department of Chemical EngineeringImperial College London SW7 2AZ London UK
| |
Collapse
|
9
|
Balne PK, Au VB, Tong L, Ghosh A, Agrawal M, Connolly J, Agrawal R. Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles. J Vis Exp 2017. [PMID: 29053687 DOI: 10.3791/55993] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
Tear film is a complex mixture of lipids, proteins and minerals which covers the external surface of the eye, thereby providing lubrication, nutrition and protection to the underlying cells. Analysis of tears is an emerging area for the identification of biomarkers for the prediction, diagnosis, and prognosis of various ocular diseases. Tears are easily accessible and their collection is non-invasive. Therefore, advancing technologies are gaining prominence for identification of multiple analytes in tears to study changes in protein or metabolite composition and its association with pathological conditions. Tear cytokines are ideal biomarkers for studying the health of the ocular surface and also help in understanding the mechanisms of different ocular surface disorders like dry eye disease and vernal conjunctivitis. Bead based multiplex assays have the capability of detecting multiple analytes in a small amount of sample with a higher sensitivity. Here we describe a standardized protocol of tear sample collection, extraction and analysis of cytokine profiling using a bead based multiplex assay.
Collapse
Affiliation(s)
- Praveen Kumar Balne
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital; Singapore Eye Research Institute (SERI)
| | | | | | | | | | | | - Rupesh Agrawal
- National Healthcare Group Eye Institute, Tan Tock Seng Hospital;
| |
Collapse
|
10
|
Hagan S, Martin E, Enríquez-de-Salamanca A. Tear fluid biomarkers in ocular and systemic disease: potential use for predictive, preventive and personalised medicine. EPMA J 2016; 7:15. [PMID: 27413414 PMCID: PMC4942926 DOI: 10.1186/s13167-016-0065-3] [Citation(s) in RCA: 196] [Impact Index Per Article: 24.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Accepted: 06/03/2016] [Indexed: 11/10/2022]
Abstract
In the field of predictive, preventive and personalised medicine, researchers are keen to identify novel and reliable ways to predict and diagnose disease, as well as to monitor patient response to therapeutic agents. In the last decade alone, the sensitivity of profiling technologies has undergone huge improvements in detection sensitivity, thus allowing quantification of minute samples, for example body fluids that were previously difficult to assay. As a consequence, there has been a huge increase in tear fluid investigation, predominantly in the field of ocular surface disease. As tears are a more accessible and less complex body fluid (than serum or plasma) and sampling is much less invasive, research is starting to focus on how disease processes affect the proteomic, lipidomic and metabolomic composition of the tear film. By determining compositional changes to tear profiles, crucial pathways in disease progression may be identified, allowing for more predictive and personalised therapy of the individual. This article will provide an overview of the various putative tear fluid biomarkers that have been identified to date, ranging from ocular surface disease and retinopathies to cancer and multiple sclerosis. Putative tear fluid biomarkers of ocular disorders, as well as the more recent field of systemic disease biomarkers, will be shown.
Collapse
Affiliation(s)
- Suzanne Hagan
- Department of Life Sciences, Vision Sciences, Glasgow Caledonian University (GCU ), G4 0BA Glasgow, Scotland, UK
| | - Eilidh Martin
- Department of Life Sciences, Vision Sciences, Glasgow Caledonian University (GCU ), G4 0BA Glasgow, Scotland, UK
| | - Amalia Enríquez-de-Salamanca
- Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain ; Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|