1
|
Altunay N, Hazer B, Farooque Lanjwani M, Tuzen M, Ul Haq H, Boczkaj G. Ultrasound assisted dispersive solid phase microextraction using polystyrene-polyoleic acid graft copolymer for determination of Sb(III) in various bottled beverages by HGAAS. Food Chem 2023; 425:136523. [PMID: 37295209 DOI: 10.1016/j.foodchem.2023.136523] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 05/26/2023] [Accepted: 05/31/2023] [Indexed: 06/12/2023]
Abstract
A new polyoleic acid-polystyrene (PoleS) block/graft copolymer was synthesized and applied as adsorbent for ultrasound assisted dispersive solid phase microextraction (UA-DSPME) of Sb(III) in different bottled beverages and analysis using hydride generation atomic absorption spectrometry (HGAAS). Adsorption capacity of the PoleS was 150 mg g-1. Several sample preparation parameters such as sorbent amount, solvent type, pH, sample volume and shaking time were optimized (based on central composite design (CCD) approach) and evaluated in respect to the recovery of Sb(III). The method revealed a high tolerance limit of matrix ions presence. Under optimized conditions, linearity range, the limit of detection, the limit of quantitation, extraction recovery, enhancement factor, preconcentration factor were 5-800 ng L-1, 1.5 ng L-1, 5.0 ng L-1, 96%, 82, 90, respectively. Accuracy of the UA-DSPME method was confirmed based on different certified reference materials and standard addition method. Factorial design was utilized to estimate the influences of variables of recovery of Sb(III).
Collapse
Affiliation(s)
- Nail Altunay
- Sivas Cumhuriyet University, Faculty of Science, Department of Chemistry, Sivas, Turkey
| | - Baki Hazer
- Kapadokya University, Department of Aircraft Airframe Engine Maintenance, Mustafapaşa Kasabası, 50420 Ürgüp, Turkey; Zonguldak Bülent Ecevit University, Departments of Chemistry/Nano Technology Engineering, 67100 Zonguldak, Turkey
| | - Muhammad Farooque Lanjwani
- Tokat Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey; Dr M. A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Sindh, Pakistan
| | - Mustafa Tuzen
- Tokat Gaziosmanpasa University, Faculty of Science and Arts, Chemistry Department, 60250 Tokat, Turkey.
| | - Hameed Ul Haq
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Sanitary Engineering, 80 - 233 Gdansk, G. Narutowicza St. 11/12, Poland
| | - Grzegorz Boczkaj
- Gdansk University of Technology, Faculty of Civil and Environmental Engineering, Department of Sanitary Engineering, 80 - 233 Gdansk, G. Narutowicza St. 11/12, Poland
| |
Collapse
|
2
|
Dong L, Wang W, Ning Y, Deng X, Gao Y. Detection of trace antimony by vanadium (IV) ion assisted photochemical vapor generation with inductively coupled plasma mass spectrometry measurement. Anal Chim Acta 2023; 1251:341006. [PMID: 36925311 DOI: 10.1016/j.aca.2023.341006] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 02/21/2023] [Accepted: 02/21/2023] [Indexed: 02/24/2023]
Abstract
In this work, a method for sensitive detection of trace antimony (Sb) was developed by inductively coupled plasma mass spectrometry (ICP MS) coupled with photochemical vapor generation (PVG). V(IV) ions were used as new "sensitizers" for improving the PVG efficiency of Sb. Factors influenced the PVG and the detection of Sb by ICP MS were investigated, including the type and concentration of low molecular weight organic acids, the UV irradiation time, the concentration of V(IV) ions, the air-liquid interface, the flow rate of Ar carrier gas, and interferences from co-existing ions. It was found that efficient reduction of Sb was obtained in the medium of 10% (v/v) formic acid (FA), 10% (v/v) acetic acid (AA), and 80 mg L-1 of V(IV) with 100 s UV irradiation. Under the selected conditions, there was no significant difference in analytical sensitivity between Sb(III) and Sb(V). The limit of detection (LOD, 3σ) was 4.7 ng L-1 for Sb with ICP MS measurement. Compared to traditional direct solution nebulization, the analytical sensitivity obtained in this work was enhanced about 19-fold. Relative standard deviations (RSDs, n = 7) were 1.9% and 2.3% for replicate measurement of 0.5 μg L-1 Sb(III) and Sb(V) standard solutions, respectively. The proposed method was applied for the determination of trace Sb in water samples and two certified reference materials (CRMs) of sediments with satisfactory results. Moreover, the generated volatile species of Sb in this work was found to be (CH3)3Sb.
Collapse
Affiliation(s)
- Liang Dong
- State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, College of Earth Sciences, Chengdu University of Technology, Sichuan, 610059, China
| | - Weigao Wang
- State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, College of Earth Sciences, Chengdu University of Technology, Sichuan, 610059, China
| | - Yongyan Ning
- State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, College of Earth Sciences, Chengdu University of Technology, Sichuan, 610059, China
| | - Xiuqin Deng
- State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, College of Earth Sciences, Chengdu University of Technology, Sichuan, 610059, China
| | - Ying Gao
- State Key Laboratory of Geohazard Prevention and Geoenvironment Protection, College of Earth Sciences, Chengdu University of Technology, Sichuan, 610059, China.
| |
Collapse
|
3
|
Kang JY, Shi YP. Recent advances and application of carbon nitride framework materials in sample preparation. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116661] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
4
|
Chen S, Liu J, Yan J, Wang C, Lu D. In-syringe solid phase extraction and in-syringe vortex-assisted solidified floating organic drop microextraction of Sb(III) and Sb(V) in rice wines with determination by graphite furnace atomic absorption spectrometry. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2022; 39:499-507. [PMID: 35061579 DOI: 10.1080/19440049.2021.2021301] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
The current non-chromatographic speciation methods generally involve the conversion of different species by oxidation/reduction reactions, which may cause inherent problems such as contamination risk, time consumption and complex operations. In this work, in-syringe solid phase extraction (IS-SPE) was combined with in-syringe vortex-assisted solidified floating organic drop microextraction (IS-VA-SFODME) for the detection of Sb(V) and Sb(III) in rice wines by graphite furnace atomic absorption spectrometry. Firstly, IS-SPE involved the use of ZnFe2O4 nanotubes as the sorbent for the isolation and enrichment of Sb(V) and removal of the matrix components such as ethanol, pigment, sugars and carbohydrates. Then, IS-VA-SFODME was used for enriching Sb(III) in the original sample solution after IS-SPE. This technique exhibited good anti-interference ability and high enrichment efficiency without tedious pre-oxidation/pre-reduction and centrifugation/filtration operations, which may cause the contamination of samples. Under the selected conditions, the detection limits were 4.5 ng L-1 and 3.2 ng L-1 for Sb(III) and Sb(V) with relative standard deviations of 7.3% and 5.1%, respectively. This procedure was used with satisfactory results for the detection of Sb(III) and Sb(V) in rice wine samples and a certified reference material of water sample. Recoveries of spiked experiments ranged from 91.0 to 107%.
Collapse
Affiliation(s)
- Shizhong Chen
- College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Jinhong Liu
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Juntao Yan
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Chunlei Wang
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Dengbo Lu
- College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China
| |
Collapse
|
5
|
Chen S, Liu Y, Wang C, Yan J, Lu D. Speciation of As(III) and As(V) in Food by Magnetic Dispersive Microsolid Phase Extraction with Dispersive Liquid–Liquid Microextraction with Graphite Furnace Atomic Absorption Spectrometry (GFAAS) Detection. ANAL LETT 2021. [DOI: 10.1080/00032719.2021.1925290] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
- Shizhong Chen
- College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Yuxiu Liu
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Chunlei Wang
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Juntao Yan
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Dengbo Lu
- College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China
| |
Collapse
|
6
|
Chen S, Liu Y, Wang C, Yan J, Lu D. Magnetic dispersive micro-solid phase extraction coupled with dispersive liquid-liquid microextraction followed by graphite furnace atomic absorption spectrometry for quantification of Se(IV) and Se(VI) in food samples. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2021; 38:1539-1550. [PMID: 34157956 DOI: 10.1080/19440049.2021.1927202] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
In this work, magnetic dispersive micro-solid phase extraction (MDMSPE) coupled with dispersive liquid-liquid microextraction (DLLME) was developed for Se(IV) and Se(VI) followed by graphite furnace atomic absorption spectrometry. MDMSPE involved the use of magnetic ZnFe2O4 nanotubes for adsorbing Se(VI). The sorbent was isolated from aqueous phase by using an external magnetic field instead of tedious centrifugation or filtration. In the following step, Se(IV) in the upper aqueous phase of MDMSPE was enriched by DLLME. Samples were prepared with artificial gastric juice to avoid the inter-conversion of target species. The main factors affecting the determination of the analytes were studied in detail. the detection limits of this method were 1.0 and 1.3 pg mL-1 for Se(IV) and Se(VI) with relative standard deviations of 4.6% and 5.1% (c = 1.0 ng mL-1, n = 9), respectively. An enrichment factor of 200 was obtained. This method was used for the detection of Se(IV) and Se(VI) in food samples without any pre-oxidation or pre-reduction operation. A certified reference material of milk powder was analysed by this method, and the determined values were in good agreement with the certified values. Recoveries of spike experiments were in the range of 91.0-107%.
Collapse
Affiliation(s)
- Shizhong Chen
- College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Yuxiu Liu
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Chunlei Wang
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Juntao Yan
- College of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan, China
| | - Dengbo Lu
- College of Food Science and Engineering, Wuhan Polytechnic University, Wuhan, China
| |
Collapse
|
7
|
Hagarová I, Nemček L. Application of Metallic Nanoparticles and Their Hybrids as Innovative Sorbents for Separation and Pre-concentration of Trace Elements by Dispersive Micro-Solid Phase Extraction: A Minireview. Front Chem 2021; 9:672755. [PMID: 34017823 PMCID: PMC8129025 DOI: 10.3389/fchem.2021.672755] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 04/12/2021] [Indexed: 11/13/2022] Open
Abstract
It is indisputable that separation techniques have found their rightful place in current analytical chemistry, considering the growing complexity of analyzed samples and (ultra)trace concentration levels of many studied analytes. Among separation techniques, extraction is one of the most popular ones due to its efficiency, simplicity, low cost and short processing times. Nonetheless, research interests are directed toward the enhancement of performance of these procedures in terms of selectivity. Dispersive solid phase extraction (DSPE) represents a novel alternative to conventional solid phase extraction (SPE) which not only delivers environment-friendly extraction with less solvent consumption, but also significantly improves analytical figures of merit. A miniaturized modification of DSPE, known as dispersive micro-solid phase extraction (DMSPE), is one of the most recent trends and can be applied for the extraction of wide variety of analytes from various liquid matrices. While DSPE procedures generally use sorbents of different origin and sizes, in DMSPE predominantly nanostructured materials are required. The aim of this paper is to provide an overview of recently published original papers on DMSPE procedures in which metallic nanoparticles and hybrid materials containing metallic particles along with other (often carbon-based) constituent(s) at the nanometer level have been utilized for separation and pre-concentration of (ultra)trace elements in liquid samples. The studies included in this review emphasize the great analytical potential of procedures producing reliable results in the analysis of complex liquid matrices, where the detection of target analyte is often complicated by the presence of interfering substances.
Collapse
Affiliation(s)
- Ingrid Hagarová
- Institute of Laboratory Research on Geomaterials, Faculty of Natural Sciences, Comenius University in Bratislava, Bratislava, Slovakia
| | - Lucia Nemček
- Institute of Laboratory Research on Geomaterials, Faculty of Natural Sciences, Comenius University in Bratislava, Bratislava, Slovakia
| |
Collapse
|
8
|
Syed SA, Al-Qahtani A, Aldughaim MS, Bari A, Kazi M. Comparative Analysis of Metal Ions and Texture of Ajwa Seed Powder Using Inductively Coupled Plasma–Mass Spectrometry. FOOD ANAL METHOD 2021. [DOI: 10.1007/s12161-020-01945-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|