1
|
Costa-Ribeiro A, Lamas A, Mora A, Prado M, Garrido-Maestu A. Moving towards on-site detection of Shiga toxin-producing Escherichia coli in ready-to-eat leafy greens. Curr Res Food Sci 2024; 8:100716. [PMID: 38511154 PMCID: PMC10950744 DOI: 10.1016/j.crfs.2024.100716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 03/01/2024] [Accepted: 03/06/2024] [Indexed: 03/22/2024] Open
Abstract
Rapid identification of Shiga toxin-producing Escherichia coli, or STEC, is of utmost importance to assure the innocuousness of the foodstuffs. STEC have been implicated in outbreaks associated with different types of foods however, among them, ready-to-eat (RTE) vegetables are particularly problematic as they are consumed raw, and are rich in compounds that inhibit DNA-based detection methods such as qPCR. In the present study a novel method based on Loop-mediated isothermal amplification (LAMP) to overcome the limitations associated with current molecular methods for the detection of STEC in RTE vegetables targeting stx1 and stx2 genes. In this sense, LAMP demonstrated to be more robust against inhibitory substances in food. In this study, a comprehensive enrichment protocol was combined with four inexpensive DNA extraction protocols. The one based on silica purification enhanced the performance of the method, therefore it was selected for its implementation in the final method. Additionally, three different detection chemistries were compared, namely real-time fluorescence detection, and two end-point colorimetric strategies, one based on the addition of SYBR Green, and the other based on a commercial colorimetric master mix. After optimization, all three chemistries demonstrated suitable for the detection of STEC in spiked RTE salad samples, as it was possible to reach a LOD50 of 0.9, 1.4, and 7.0 CFU/25 g for the real-time, SYBR and CC LAMP assays respectively. All the performance parameters reached values higher than 90 %, when compared to a reference method based on multiplex qPCR. More specifically, the analytical sensitivity was 100, 90.0 and 100 % for real-time, SYBR and CC LAMP respectively, the specificity 100 % for all three assays, and accuracy 100, 96 and 100 %. Finally, a high degree of concordance was also obtained (1, 0.92 and 1 respectively). Considering the current technological advances, the method reported, using any of the three detection strategies, demonstrated suitable for their implementation in decentralized settings, with low equipment resources.
Collapse
Affiliation(s)
- Ana Costa-Ribeiro
- International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga s/n, 4715-330, Braga, Portugal
- Department of Biochemistry, Genetics and Immunology, University of Vigo, 36310, Vigo, Spain
| | - Alexandre Lamas
- Food Hygiene, Inspection and Control Laboratory (Lhica), Department of Analytical Chemistry, Nutrition, and Bromatology, Veterinary School, Campus Terra, Universidade de Santiago de Compostela (USC), 27002, Lugo, Spain
| | - Azucena Mora
- Laboratorio de Referencia de E. coli (LREC), Dpto. de Microbioloxía e Parasitoloxía, Facultade de Veterinaria, Universidade de Santiago de Compostela (USC), Lugo, Spain
- Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago, Spain
| | - Marta Prado
- International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga s/n, 4715-330, Braga, Portugal
- Food Hygiene, Inspection and Control Laboratory (Lhica), Department of Analytical Chemistry, Nutrition, and Bromatology, Veterinary School, Campus Terra, Universidade de Santiago de Compostela (USC), 27002, Lugo, Spain
| | - Alejandro Garrido-Maestu
- International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga s/n, 4715-330, Braga, Portugal
- Laboratory of Microbiology and Technology of Marine Products (MicroTEC), Instituto de Investigaciones Marinas (IIM), CSIC, Eduardo Cabello, 6, 36208, Vigo, Spain
| |
Collapse
|
2
|
Yinur D, Moges B, Hassen A, Tessema TS. Loop mediated isothermal amplification as a molecular diagnostic assay: Application and evaluation for detection of Enterohaemorrhagic Escherichia coli (O157:H7). Pract Lab Med 2023; 37:e00333. [PMID: 37693632 PMCID: PMC10492192 DOI: 10.1016/j.plabm.2023.e00333] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 07/27/2023] [Accepted: 08/25/2023] [Indexed: 09/12/2023] Open
Abstract
Purpose This study aimed at evaluating the performance of the Loop Mediated Isothermal Amplification (LAMP) diagnostic test, which targets the putative Fimbria protein-encoding gene (Z3276) for rapid and specific detection of locally isolated enterohemorrhagic Escherichia coli (EHEC) O157:H7. Results A total number of 40 locally available bacteria isolates and standard strains, among them 6 entrohemorrhagic (O157:H7) and 10 entropathogenic E. coli, 7 non diarrheic E. coli strains and 13 non entrohemorrhagic shiga toxic (stx) E. coli isolates as well as 4 pathogenic non E. coli species were used to optimize and evaluate the LAMP assay. The LAMP amplified DNA samples were visualized as turbid DNA both by naked eye and gel electrophoresis followed by staining. The assay had a sensitivity of 100% (6/6), a specificity of 97.05% (33/34), and an efficiency of 97.5% (39/40). The assay was also exhibited with 100% negative predicted value and 85.7% positive predicted value. The LAMP assay was also 10-fold more sensitive than the conventional PCR assay; sensitivity was determined by serial dilution. The results of LAMP and the PCR tests showed very high agreement (k = 0.97) in the detection of the bacteria studied. Conclusion Compared with the performance of PCR and SMAC, LAMP assay was better in terms of efficiency, rapidity and cost-effectiveness, which can be used as a point-care diagnostic test in resource-limited laboratories.
Collapse
Affiliation(s)
- Degisew Yinur
- Department of Medical Biotechnology, Institute of Biotechnology, University of Gondar, Gondar, Ethiopia
| | - Biniam Moges
- Department of Biotechnology, Debre Berhan University, Debre Berhan, Ethiopia
| | - Aliyi Hassen
- Department of Biotechnology, Ambo University, Ambo, Ethiopia
| | | |
Collapse
|
3
|
Wang Z, Cui X, Hu A, Lu Z, Meng F, Zhou L, Bie X. Establishment of real-time fluorescence and visual LAMP for rapid detection of Escherichia coli O157:H7 and kits construction. Lett Appl Microbiol 2023; 76:ovad122. [PMID: 37863833 DOI: 10.1093/lambio/ovad122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 09/23/2023] [Accepted: 10/19/2023] [Indexed: 10/22/2023]
Abstract
Escherichia coli O157:H7 is a common pathogenic bacterium in food and water that can pose a threat to human health. The aim of this study was to develop loop-mediated isothermal amplification (LAMP) method for the detection of E. coli O157:H7 in food based on the specific gene Ecs_2840 and to construct rapid detection kits based on the established methods. Specifically, we established two methods of real-time fluorescent LAMP (RT-LAMP) and visual LAMP with calcein as an indicator. In pure bacterial culture, the cell sensitivity and genomic sensitivity of the RT-LAMP kit were 8.8 × 100 CFU ml-1 and 4.61 fg µl-1, respectively. The sensitivity of the visual LAMP kit was 2.35 × 100 CFU ml-1 and 4.61 fg µl-1. Both kits had excellent specificity and anti-interference performance. In addition, milk inoculated with 2.26 × 100 CFU ml-1E. coli O157:H7 could be detected within the reaction time after enrichment for 3 h. The results showed that the LAMP kits were rapid, sensitive, and specific for the detection of E. coli O157:H7 in food and had good application prospects in food safety surveillance.
Collapse
Affiliation(s)
- Zuwei Wang
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| | - Xinping Cui
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| | - Antuo Hu
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| | - Zhaoxin Lu
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| | - Fanqiang Meng
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| | - Libang Zhou
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| | - Xiaomei Bie
- Nanjing Agricultural University, College of Food Science and Technology, Nanjing 210095, People's Republic of China
| |
Collapse
|
4
|
Jena S, Gaur D, Dubey NC, Tripathi BP. Advances in paper based isothermal nucleic acid amplification tests for water-related infectious diseases. Int J Biol Macromol 2023:125089. [PMID: 37245760 DOI: 10.1016/j.ijbiomac.2023.125089] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 05/14/2023] [Accepted: 05/22/2023] [Indexed: 05/30/2023]
Abstract
Water-associated or water-related infectious disease outbreaks are caused by pathogens such as bacteria, viruses, and protozoa, which can be transmitted through contaminated water sources, poor sanitation practices, or insect vectors. Low- and middle-income countries bear the major burden of these infections due to inadequate hygiene and subpar laboratory facilities, making it challenging to monitor and detect infections in a timely manner. However, even developed countries are not immune to these diseases, as inadequate wastewater management and contaminated drinking water supplies can also contribute to disease outbreaks. Nucleic acid amplification tests have proven to be effective for early disease intervention and surveillance of both new and existing diseases. In recent years, paper-based diagnostic devices have made significant progress and become an essential tool in detecting and managing water-associated diseases. In this review, we highlight the importance of paper and its variants as a diagnostic tool and discuss the properties, design modifications, and various paper-based device formats developed and used for detecting water-associated pathogens.
Collapse
Affiliation(s)
- Saikrushna Jena
- Department of Materials Science & Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India
| | - Divya Gaur
- Department of Materials Science & Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India
| | - Nidhi C Dubey
- Department of Molecular Medicine, Jamia Hamdard, New Delhi 110062, India
| | - Bijay P Tripathi
- Department of Materials Science & Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India.
| |
Collapse
|
5
|
Point-of-Care Lateral Flow Detection of Viable Escherichia coli O157:H7 Using an Improved Propidium Monoazide-Recombinase Polymerase Amplification Method. Foods 2022; 11:3207. [PMCID: PMC9602316 DOI: 10.3390/foods11203207] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The detection of both viable and viable but non-culturable (VBNC) Escherichia coli O157:H7 is a crucial part of food safety. Traditional culture-dependent methods are lengthy, expensive, laborious, and unable to detect VBNC. Hence, there is a need to develop a rapid, simple, and cost-effective detection method to differentiate between viable/dead E. coli O157:H7 and detect VBNC cells. In this work, recombinase polymerase amplification (RPA) was developed for the detection of viable E. coli O157:H7 through integration with propidium monoazide (PMAxx). Initially, two primer sets, targeting two different genes (rfbE and stx) were selected, and DNA amplification by RPA combined with PMAxx treatment and the lateral flow assay (LFA) was carried out. Subsequently, the rfbE gene target was found to be more effective in inhibiting the amplification from dead cells and detecting only viable E. coli O157:H7. The assay’s detection limit was found to be 102 CFU/mL for VBNC E. coli O157:H7 when applied to spiked commercial beverages including milk, apple juice, and drinking water. pH values from 3 to 11 showed no significant effect on the efficacy of the assay. The PMAxx-RPA-LFA was completed at 39 °C within 40 min. This study introduces a rapid, robust, reliable, and reproducible method for detecting viable bacterial counts. In conclusion, the optimised assay has the potential to be used by the food and beverage industry in quality assurance related to E. coli O157:H7.
Collapse
|