1
|
Saaidi R, Rodríguez-Villafuerte M, Alva-Sánchez H, Martínez-Dávalos A. Crystal scatter effects in a large-area dual-panel Positron Emission Mammography system. PLoS One 2024; 19:e0297829. [PMID: 38427663 PMCID: PMC10906883 DOI: 10.1371/journal.pone.0297829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 01/11/2024] [Indexed: 03/03/2024] Open
Abstract
Positron Emission Mammography (PEM) is a valuable molecular imaging technique for breast studies using pharmaceuticals labeled with positron emitters and dual-panel detectors. PEM scanners normally use large scintillation crystals coupled to sensitive photodetectors. Multiple interactions of the 511 keV annihilation photons in the crystals can result in event mispositioning leading to a negative impact in radiopharmaceutical uptake quantification. In this work, we report the study of crystal scatter effects of a large-area dual-panel PEM system designed with either monolithic or pixelated lutetium yttrium orthosilicate (LYSO) crystals using the Monte Carlo simulation platform GATE. The results show that only a relatively small fraction of coincidences (~20%) arise from events where both coincidence photons undergo single interactions (mostly through photoelectric absorption) in the crystals. Most of the coincidences are events where at least one of the annihilation photons undergoes a chain of Compton scatterings: approximately 79% end up in photoelectric absorption while the rest (<1%) escape the detector. Mean positioning errors, calculated as the distance between first hit and energy weighted (assigned) positions of interaction, were 1.70 mm and 1.92 mm for the monolithic and pixelated crystals, respectively. Reconstructed spatial resolution quantification with a miniDerenzo phantom and a list mode iterative reconstruction algorithm shows that, for both crystal types, 2 mm diameter hot rods were resolved, indicating a relatively small effect in spatial resolution. A drastic reduction in peak-to-valley ratios for the same hot-rod diameters was observed, up to a factor of 14 for the monolithic crystals and 7.5 for the pixelated ones.
Collapse
Affiliation(s)
- Rahal Saaidi
- Instituto de Física, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, Mexico City, Mexico
| | | | - Héctor Alva-Sánchez
- Instituto de Física, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, Mexico City, Mexico
| | - Arnulfo Martínez-Dávalos
- Instituto de Física, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, Mexico City, Mexico
| |
Collapse
|
2
|
Saleh GA, Batouty NM, Gamal A, Elnakib A, Hamdy O, Sharafeldeen A, Mahmoud A, Ghazal M, Yousaf J, Alhalabi M, AbouEleneen A, Tolba AE, Elmougy S, Contractor S, El-Baz A. Impact of Imaging Biomarkers and AI on Breast Cancer Management: A Brief Review. Cancers (Basel) 2023; 15:5216. [PMID: 37958390 PMCID: PMC10650187 DOI: 10.3390/cancers15215216] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/13/2023] [Accepted: 10/21/2023] [Indexed: 11/15/2023] Open
Abstract
Breast cancer stands out as the most frequently identified malignancy, ranking as the fifth leading cause of global cancer-related deaths. The American College of Radiology (ACR) introduced the Breast Imaging Reporting and Data System (BI-RADS) as a standard terminology facilitating communication between radiologists and clinicians; however, an update is now imperative to encompass the latest imaging modalities developed subsequent to the 5th edition of BI-RADS. Within this review article, we provide a concise history of BI-RADS, delve into advanced mammography techniques, ultrasonography (US), magnetic resonance imaging (MRI), PET/CT images, and microwave breast imaging, and subsequently furnish comprehensive, updated insights into Molecular Breast Imaging (MBI), diagnostic imaging biomarkers, and the assessment of treatment responses. This endeavor aims to enhance radiologists' proficiency in catering to the personalized needs of breast cancer patients. Lastly, we explore the augmented benefits of artificial intelligence (AI), machine learning (ML), and deep learning (DL) applications in segmenting, detecting, and diagnosing breast cancer, as well as the early prediction of the response of tumors to neoadjuvant chemotherapy (NAC). By assimilating state-of-the-art computer algorithms capable of deciphering intricate imaging data and aiding radiologists in rendering precise and effective diagnoses, AI has profoundly revolutionized the landscape of breast cancer radiology. Its vast potential holds the promise of bolstering radiologists' capabilities and ameliorating patient outcomes in the realm of breast cancer management.
Collapse
Affiliation(s)
- Gehad A. Saleh
- Diagnostic and Interventional Radiology Department, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt; (G.A.S.)
| | - Nihal M. Batouty
- Diagnostic and Interventional Radiology Department, Faculty of Medicine, Mansoura University, Mansoura 35516, Egypt; (G.A.S.)
| | - Abdelrahman Gamal
- Computer Science Department, Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt (A.E.T.)
| | - Ahmed Elnakib
- Electrical and Computer Engineering Department, School of Engineering, Penn State Erie, The Behrend College, Erie, PA 16563, USA;
| | - Omar Hamdy
- Surgical Oncology Department, Oncology Centre, Mansoura University, Mansoura 35516, Egypt;
| | - Ahmed Sharafeldeen
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA
| | - Ali Mahmoud
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA
| | - Mohammed Ghazal
- Electrical, Computer, and Biomedical Engineering Department, Abu Dhabi University, Abu Dhabi 59911, United Arab Emirates; (M.G.)
| | - Jawad Yousaf
- Electrical, Computer, and Biomedical Engineering Department, Abu Dhabi University, Abu Dhabi 59911, United Arab Emirates; (M.G.)
| | - Marah Alhalabi
- Electrical, Computer, and Biomedical Engineering Department, Abu Dhabi University, Abu Dhabi 59911, United Arab Emirates; (M.G.)
| | - Amal AbouEleneen
- Computer Science Department, Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt (A.E.T.)
| | - Ahmed Elsaid Tolba
- Computer Science Department, Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt (A.E.T.)
- The Higher Institute of Engineering and Automotive Technology and Energy, New Heliopolis, Cairo 11829, Egypt
| | - Samir Elmougy
- Computer Science Department, Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt (A.E.T.)
| | - Sohail Contractor
- Department of Radiology, University of Louisville, Louisville, KY 40202, USA
| | - Ayman El-Baz
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA
| |
Collapse
|
3
|
Hrynchak I, Santos L, Falcão A, Gomes CM, Abrunhosa AJ. Nanobody-Based Theranostic Agents for HER2-Positive Breast Cancer: Radiolabeling Strategies. Int J Mol Sci 2021; 22:ijms221910745. [PMID: 34639086 PMCID: PMC8509594 DOI: 10.3390/ijms221910745] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 09/29/2021] [Accepted: 10/01/2021] [Indexed: 02/07/2023] Open
Abstract
The overexpression of human epidermal growth factor 2 (HER2) in breast cancer (BC) has been associated with a more aggressive tumor subtype, poorer prognosis and shorter overall survival. In this context, the development of HER2-targeted radiotracers is crucial to provide a non-invasive assessment of HER2 expression to select patients for HER2-targeted therapies, monitor response and identify those who become resistant. Antibodies represent ideal candidates for this purpose, as they provide high contrast images for diagnosis and low toxicity in the therapeutic setting. Of those, nanobodies (Nb) are of particular interest considering their favorable kinetics, crossing of relevant biological membranes and intratumoral distribution. The purpose of this review is to highlight the unique characteristics and advantages of Nb-based radiotracers in BC imaging and therapy. Additionally, radiolabeling methods for Nb including direct labeling, indirect labeling via prosthetic group and indirect labeling via complexation will be discussed, reporting advantages and drawbacks. Furthermore, the preclinical to clinical translation of radiolabeled Nbs as promising theranostic agents will be reported.
Collapse
Affiliation(s)
- Ivanna Hrynchak
- ICNAS-Produção Unipessoal, Lda.—University of Coimbra, 3000-548 Coimbra, Portugal; (I.H.); (L.S.)
- CIBIT/ICNAS—Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal;
| | - Liliana Santos
- ICNAS-Produção Unipessoal, Lda.—University of Coimbra, 3000-548 Coimbra, Portugal; (I.H.); (L.S.)
- CIBIT/ICNAS—Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal;
| | - Amílcar Falcão
- CIBIT/ICNAS—Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal;
| | - Célia M. Gomes
- iCBR—Coimbra Institute for Clinical and Biomedical Research, Faculty of Medicine, University of Coimbra, 3000-548 Coimbra, Portugal;
- CIBB—Center for Innovative Biomedicine and Biotechnology, University of Coimbra, 3000-548 Coimbra, Portugal
- CACC—Clinical Academic Center of Coimbra, 3000-075 Coimbra, Portugal
| | - Antero J. Abrunhosa
- ICNAS-Produção Unipessoal, Lda.—University of Coimbra, 3000-548 Coimbra, Portugal; (I.H.); (L.S.)
- CIBIT/ICNAS—Institute for Nuclear Sciences Applied to Health, University of Coimbra, 3000-548 Coimbra, Portugal;
- Correspondence:
| |
Collapse
|
4
|
Keshavarz K, Jafari M, Lotfi F, Bastani P, Salesi M, Gheisari F, Rezaei Hemami M. Positron Emission Mammography (PEM) in the diagnosis of breast cancer: A systematic review and economic evaluation. Med J Islam Repub Iran 2020; 34:100. [PMID: 33315994 PMCID: PMC7722955 DOI: 10.34171/mjiri.34.100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Indexed: 12/09/2022] Open
Abstract
Background: Positron Emission Mammography (PEM) is an imaging technique which is increasing focuses on imaging the chest instead of imaging the whole body. The aim of this study was to conduct a systematic review of the clinical efficacy and coste-ffectiveness of PEM technology, as compared with PET, as a diagnostic method used for breast cancer patients.
Methods: The present study was a Health Technology Assessment (HTA), which was conducted via a systematic review of clinical efficacy and cost-effectiveness of the methods based on domestic evidence. To evaluate the efficacy of the PEM diagnostic method, as compared with PET, we used efficacy indices, including Sensitivity, Specificity, Accuracy, PPV, and NPV. The required data were collected through a meta-analysis of studies published in electronic databases from 1990 to 2016. In addition, direct costs in both methods were estimated and finally, a cost-effectiveness analysis was performed using the results of the study. Also, a one-way sensitivity analysis was performed to examine the effects of parameters’ uncertainty in the model. In this study, we used STATA software to integrate the results of studies with similar parameters.
Results: A total of 722 cases (N) were obtained from the five final studies. The results of the meta-analysis performed on the collected data showed that the two methods were identical in terms of the Specificity and PPV parameters. However, as to Sensitivity, NPV, and Accuracy parameters, the PEM method was superior to the PET for diagnosis of primary breast cancer. The total cost of using PEM and PET was $1737385.7 and $1940903.5, respectively, and the cost of a one-time scan (cost per unit) using PEM and PET devices was $86.82 and $157.63, respectively. As compared with the PET method, the use of the PEM diagnostic method for diagnosis of breast cancer was cost-effective in terms of all the five studied parameters (it was definitely cost-effective for four parameters and was also considered as cost-effective for another index, since ICER was below the threshold).
Conclusion: The results showed that the use of PEM technology for the diagnosis of primary breast cancer is more cost-effective than PET technology; thus, due to the wide range of PET technology in different fields, it is recommended that this method should be used in other areas of priority.
Collapse
Affiliation(s)
- Khosro Keshavarz
- Health Human Resources Research Center, School of Management and Medical Informatics, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mojtaba Jafari
- Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Farhad Lotfi
- Health Human Resources Research Center, School of Management and Medical Informatics, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Peivand Bastani
- Health Human Resources Research Center, School of Management and Medical Informatics, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Mahmood Salesi
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran
| | - Farshid Gheisari
- Faculty of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.,Ionizing and Non-Ionizing Radiation Protection Research Center, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iran
| | | |
Collapse
|
5
|
Multiple Bilateral Circumscribed Breast Masses Detected at Imaging: Review of Evidence for Management Recommendations. AJR Am J Roentgenol 2019; 214:276-281. [PMID: 31825259 DOI: 10.2214/ajr.19.22061] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE. Historically, management recommendations for multiple bilateral circumscribed breast masses encountered with breast imaging have varied. This article reviews the evidence and provides best-practice recommendations for managing these masses. CONCLUSION. Meticulous imaging technique and interpretation are required to correctly diagnose multiple bilateral circumscribed breast masses. Radiologists should classify such masses identified at mammography, digital breast tomosynthesis, or bilateral whole-breast sonography as benign and recommend annual follow-up. Elucidating the significance of these masses on MRI, contrast-enhanced mammography, or nuclear breast imaging requires further study.
Collapse
|
6
|
Advanced approaches to imaging primary breast cancer: an update. Clin Transl Imaging 2019. [DOI: 10.1007/s40336-019-00346-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
7
|
Paydary K, Seraj SM, Zadeh MZ, Emamzadehfard S, Shamchi SP, Gholami S, Werner TJ, Alavi A. The Evolving Role of FDG-PET/CT in the Diagnosis, Staging, and Treatment of Breast Cancer. Mol Imaging Biol 2019. [PMID: 29516387 DOI: 10.1007/s11307-018-1181-3] [Citation(s) in RCA: 101] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The applications of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography/X-ray computed tomography (PET/CT) in the management of patients with breast cancer have been extensively studied. According to these studies, PET/CT is not routinely performed for the diagnosis of primary breast cancer, although PET/CT in specific subtypes of breast cancer correlates with histopathologic features of the primary tumor. PET/CT can detect metastases to mediastinal, axial, and internal mammary nodes, but it cannot replace the sentinel node biopsy. In detection of distant metastases, this imaging tool may have a better accuracy in detecting lytic bone metastases compared to bone scintigraphy. Thus, PET/CT is recommended when advanced-stage disease is suspected, and conventional modalities are inconclusive. Also, PET/CT has a high sensitivity and specificity to detect loco-regional recurrence and is recommended in asymptomatic patients with rising tumor markers. Numerous studies support the future role of PET/CT in prediction of response to neoadjuvant chemotherapy (NAC). PET/CT has a higher diagnostic value for prognostic risk stratification in comparison with conventional modalities. With the continuing research on the treatment planning and evaluation of patients with breast cancer, the role of PET/CT can be further extended.
Collapse
Affiliation(s)
- Koosha Paydary
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | | | | | | | | | - Saeid Gholami
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Thomas J Werner
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Abass Alavi
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA. .,Division of Nuclear Medicine, Department of Radiology, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA, 19104, USA.
| |
Collapse
|
8
|
Narayanan D, Berg WA. Use of Breast-Specific PET Scanners and Comparison with MR Imaging. Magn Reson Imaging Clin N Am 2018; 26:265-272. [PMID: 29622131 DOI: 10.1016/j.mric.2017.12.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The goals of this article are to discuss the role of breast-specific PET imaging of women with breast cancer, compare the clinical performance of positron emission mammography (PEM) and MR imaging for current indications, and provide recommendations for when women should undergo PEM instead of breast MR imaging.
Collapse
Affiliation(s)
- Deepa Narayanan
- SBIR Development Center, National Cancer Institute, 9609 Medical Center Drive, Rockville, MD 20850, USA.
| | - Wendie A Berg
- Department of Radiology, University of Pittsburgh School of Medicine, Magee-Womens Hospital of UPMC, 300 Halket Street, Pittsburgh, PA 15213, USA
| |
Collapse
|
9
|
Improving women's health in low-income and middle-income countries. Part II: the needs of diagnostic imaging. Nucl Med Commun 2018; 38:1024-1028. [PMID: 28953209 PMCID: PMC5704652 DOI: 10.1097/mnm.0000000000000752] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
10
|
Guo R, Lu G, Qin B, Fei B. Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:37-70. [PMID: 29107353 PMCID: PMC6169997 DOI: 10.1016/j.ultrasmedbio.2017.09.012] [Citation(s) in RCA: 241] [Impact Index Per Article: 34.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 09/12/2017] [Accepted: 09/13/2017] [Indexed: 05/25/2023]
Abstract
Ultrasound imaging is a commonly used modality for breast cancer detection and diagnosis. In this review, we summarize ultrasound imaging technologies and their clinical applications for the management of breast cancer patients. The technologies include ultrasound elastography, contrast-enhanced ultrasound, 3-D ultrasound, automatic breast ultrasound and computer-aided detection of breast ultrasound. We summarize the study results seen in the literature and discuss their future directions. We also provide a review of ultrasound-guided, breast biopsy and the fusion of ultrasound with other imaging modalities, especially magnetic resonance imaging (MRI). For comparison, we also discuss the diagnostic performance of mammography, MRI, positron emission tomography and computed tomography for breast cancer diagnosis at the end of this review. New ultrasound imaging techniques, ultrasound-guided biopsy and the fusion of ultrasound with other modalities provide important tools for the management of breast patients.
Collapse
Affiliation(s)
- Rongrong Guo
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA; Department of Ultrasound, Shanxi Provincial Cancer Hospital, Taiyuan, Shanxi, China
| | - Guolan Lu
- The Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Binjie Qin
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Baowei Fei
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA; The Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA; Department of Mathematics and Computer Science, Emory College of Emory University, Atlanta, Georgia, USA; Winship Cancer Institute of Emory University, Atlanta, Georgia, USA.
| |
Collapse
|
11
|
Materia ME, Pernia Leal M, Scotto M, Balakrishnan PB, Kumar Avugadda S, García-Martín ML, Cohen BE, Chan EM, Pellegrino T. Multifunctional Magnetic and Upconverting Nanobeads as Dual Modal Imaging Tools. Bioconjug Chem 2017; 28:2707-2714. [PMID: 28945361 PMCID: PMC6091499 DOI: 10.1021/acs.bioconjchem.7b00432] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
![]()
We
report the fabrication of aqueous multimodal imaging nanocomposites
based on superparamagnetic nanoparticles (MNPs) and two different
sizes of photoluminescent upconverting nanoparticles (UCNPs). The
controlled and simultaneous incorporation of both types of nanoparticles
(NPs) was obtained by controlling the solvent composition and the
addition rate of the destabilizing solvent. The magnetic properties
of the MNPs remained unaltered after their encapsulation into the
polymeric beads as shown by the T2 relaxivity measurements. The UCNPs
maintain photoluminescent properties even when embedded with the MNPs
into the polymer bead. Moreover, the light emitted by the magnetic
and upconverting nanobeads (MUCNBs) under NIR excitation (λexc = 980 nm) was clearly observed through different thicknesses
of agarose gel or through a mouse skin layer. The comparison with
magnetic and luminescent nanobeads based on red-emitting quantum dots
(QDs) demonstrated that while the QD-based beads show significant
autofluorescence background from the skin, the signal obtained by
the MUCNBs allows a decrease in this background. In summary, these
results indicate that MUCNBs are good magnetic and optical probes
for in vivo multimodal imaging sensors.
Collapse
Affiliation(s)
| | - Manuel Pernia Leal
- Istituto Italiano di Tecnologia , Via Morego 30, 16163 Genova, Italy.,BIONAND, Andalusian Centre for Nanomedicine and Biotechnology (Junta de Andalucía-Universidad de Málaga) , 29590 Málaga, Spain
| | - Marco Scotto
- Istituto Italiano di Tecnologia , Via Morego 30, 16163 Genova, Italy
| | | | | | - María L García-Martín
- BIONAND, Andalusian Centre for Nanomedicine and Biotechnology (Junta de Andalucía-Universidad de Málaga) , 29590 Málaga, Spain
| | - Bruce E Cohen
- The Molecular Foundry, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - Emory M Chan
- The Molecular Foundry, Lawrence Berkeley National Laboratory , Berkeley, California 94720, United States
| | - Teresa Pellegrino
- Istituto Italiano di Tecnologia , Via Morego 30, 16163 Genova, Italy
| |
Collapse
|
12
|
Slavine NV, Seiler SJ, McColl RW, Lenkinski RE. Image improvement method for positron emission mammography. Phys Med 2017; 39:164-173. [PMID: 28688583 DOI: 10.1016/j.ejmp.2017.06.025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2016] [Revised: 06/09/2017] [Accepted: 06/29/2017] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To evaluate in clinical use a rapidly converging, efficient iterative deconvolution algorithm (RSEMD) for improving the quantitative accuracy of previously reconstructed breast images by a commercial positron emission mammography (PEM) scanner. MATERIALS AND METHODS The RSEMD method was tested on imaging data from clinical Naviscan Flex Solo II PEM scanner. This method was applied to anthropomorphic like breast phantom data and patient breast images previously reconstructed with Naviscan software to determine improvements in image resolution, signal to noise ratio (SNR) and contrast to noise ratio (CNR). RESULTS In all of the patients' breast studies the improved images proved to have higher resolution, contrast and lower noise as compared with images reconstructed by conventional methods. In general, the values of CNR reached a plateau at an average of 6 iterations with an average improvement factor of about 2 for post-reconstructed Flex Solo II PEM images. Improvements in image resolution after the application of RSEMD have also been demonstrated. CONCLUSIONS A rapidly converging, iterative deconvolution algorithm with a resolution subsets-based approach (RSEMD) that operates on patient DICOM images has been used for quantitative improvement in breast imaging. The RSEMD method can be applied to PEM images to enhance the resolution and contrast in cancer diagnosis to monitor the tumor progression at the earliest stages.
Collapse
Affiliation(s)
- Nikolai V Slavine
- Translational Research, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9061, USA.
| | - Stephen J Seiler
- Breast Imaging, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9061, USA
| | - Roderick W McColl
- Clinical Medical Physics, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9061, USA
| | - Robert E Lenkinski
- Translational Research, Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9061, USA
| |
Collapse
|
13
|
Zimmermann BB, Deng B, Singh B, Martino M, Selb J, Fang Q, Sajjadi AY, Cormier J, Moore RH, Kopans DB, Boas DA, Saksena MA, Carp SA. Multimodal breast cancer imaging using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:46008. [PMID: 28447102 PMCID: PMC5406652 DOI: 10.1117/1.jbo.22.4.046008] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Accepted: 04/07/2017] [Indexed: 05/02/2023]
Abstract
Diffuse optical tomography (DOT) is emerging as a noninvasive functional imaging method for breast cancer diagnosis and neoadjuvant chemotherapy monitoring. In particular, the multimodal approach of combining DOT with x-ray digital breast tomosynthesis (DBT) is especially synergistic as DBT prior information can be used to enhance the DOT reconstruction. DOT, in turn, provides a functional information overlay onto the mammographic images, increasing sensitivity and specificity to cancer pathology. We describe a dynamic DOT apparatus designed for tight integration with commercial DBT scanners and providing a fast (up to 1 Hz) image acquisition rate to enable tracking hemodynamic changes induced by the mammographic breast compression. The system integrates 96 continuous-wave and 24 frequency-domain source locations as well as 32 continuous wave and 20 frequency-domain detection locations into low-profile plastic plates that can easily mate to the DBT compression paddle and x-ray detector cover, respectively. We demonstrate system performance using static and dynamic tissue-like phantoms as well as in vivo images acquired from the pool of patients recalled for breast biopsies at the Massachusetts General Hospital Breast Imaging Division.
Collapse
Affiliation(s)
- Bernhard B. Zimmermann
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, Cambridge, Massachusetts, United States
| | - Bin Deng
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
| | - Bhawana Singh
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
| | - Mark Martino
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
| | - Juliette Selb
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
| | - Qianqian Fang
- Northeastern University, Department of Bioengineering, Boston, Massachusetts, United States
| | - Amir Y. Sajjadi
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
| | - Jayne Cormier
- Massachusetts General Hospital, Breast Imaging Division, Department of Radiology, Boston, Massachusetts, United States
| | - Richard H. Moore
- Massachusetts General Hospital, Breast Imaging Division, Department of Radiology, Boston, Massachusetts, United States
| | - Daniel B. Kopans
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
- Massachusetts General Hospital, Breast Imaging Division, Department of Radiology, Boston, Massachusetts, United States
| | - David A. Boas
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
| | - Mansi A. Saksena
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
- Massachusetts General Hospital, Breast Imaging Division, Department of Radiology, Boston, Massachusetts, United States
| | - Stefan A. Carp
- Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown, Massachusetts, United States
- Harvard Medical School, Department of Radiology, Boston, Massachusetts, United States
- Address all correspondence to: Stefan A. Carp, E-mail:
| |
Collapse
|
14
|
Bitencourt AGV, Lima ENP, Macedo BRC, Conrado JLFA, Marques EF, Chojniak R. Can positron emission mammography help to identify clinically significant breast cancer in women with suspicious calcifications on mammography? Eur Radiol 2016; 27:1893-1900. [PMID: 27585658 DOI: 10.1007/s00330-016-4576-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 07/24/2016] [Accepted: 08/22/2016] [Indexed: 01/21/2023]
Abstract
OBJECTIVE To evaluate the diagnostic accuracy of positron emission mammography (PEM) for identifying malignant lesions in patients with suspicious microcalcifications detected on mammography. METHODS A prospective, single-centre study that evaluated 40 patients with suspicious calcifications at mammography and indication for percutaneous or surgical biopsy, with mean age of 56.4 years (range: 28-81 years). Patients who agreed to participate in the study underwent PEM with 18F-fluorodeoxyglucose before the final histological evaluation. PEM findings were compared with mammography and histological findings. RESULTS Most calcifications (n = 34; 85.0 %) were classified as BIRADS 4. On histology, there were 25 (62.5 %) benign and 15 (37.5 %) malignant lesions, including 11 (27.5 %) ductal carcinoma in situ (DCIS) and 4 (10 %) invasive carcinomas. On subjective analysis, PEM was positive in 15 cases (37.5 %) and most of these cases (n = 14; 93.3 %) were confirmed as malignant on histology. There was one false-positive result, which corresponded to a fibroadenoma, and one false negative, which corresponded to an intermediate-grade DCIS. PEM had a sensitivity of 93.3 %, specificity of 96.0 % and accuracy of 95 %. CONCLUSION PEM was able to identify all invasive carcinomas and high-grade DCIS (nuclear grade 3) in the presented sample, suggesting that this method may be useful for further evaluation of patients with suspected microcalcifications. KEY POINTS • Many patients with suspicious microcalcifications at mammography have benign results at biopsy. • PEM may help to identify invasive carcinomas and high-grade DCIS. • Management of patients with suspicious calcifications can be improved.
Collapse
Affiliation(s)
- Almir G V Bitencourt
- A C Camargo Cancer Center-Department of Imaging, R. Prof. Antônio Prudente, 211, São Paulo, SP, Brazil, 01509-010.
| | - Eduardo N P Lima
- A C Camargo Cancer Center-Department of Imaging, R. Prof. Antônio Prudente, 211, São Paulo, SP, Brazil, 01509-010
| | - Bruna R C Macedo
- A C Camargo Cancer Center-Department of Imaging, R. Prof. Antônio Prudente, 211, São Paulo, SP, Brazil, 01509-010
| | - Jorge L F A Conrado
- A C Camargo Cancer Center-Department of Imaging, R. Prof. Antônio Prudente, 211, São Paulo, SP, Brazil, 01509-010
| | - Elvira F Marques
- A C Camargo Cancer Center-Department of Imaging, R. Prof. Antônio Prudente, 211, São Paulo, SP, Brazil, 01509-010
| | - Rubens Chojniak
- A C Camargo Cancer Center-Department of Imaging, R. Prof. Antônio Prudente, 211, São Paulo, SP, Brazil, 01509-010
| |
Collapse
|
15
|
ADVANTAGE OF CORE NEEDLE BIOPSY OVER FINE NEEDLE ASPIRATION CYTOLOGY IN PALPABLE BREAST LUMPS. ACTA ACUST UNITED AC 2016. [DOI: 10.14260/jemds/2016/1085] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
16
|
Leithner D, Baltzer PA, Magometschnigg HF, Wengert GJ, Karanikas G, Helbich TH, Weber M, Wadsak W, Pinker K. Quantitative Assessment of Breast Parenchymal Uptake on 18F-FDG PET/CT: Correlation with Age, Background Parenchymal Enhancement, and Amount of Fibroglandular Tissue on MRI. J Nucl Med 2016; 57:1518-1522. [PMID: 27230924 DOI: 10.2967/jnumed.116.174904] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Accepted: 04/12/2016] [Indexed: 01/26/2023] Open
Abstract
Background parenchymal enhancement (BPE), and the amount of fibroglandular tissue (FGT) assessed with MRI have been implicated as sensitive imaging biomarkers for breast cancer. The purpose of this study was to quantitatively assess breast parenchymal uptake (BPU) on 18F-FDG PET/CT as another valuable imaging biomarker and examine its correlation with BPE, FGT, and age. METHODS This study included 129 patients with suspected breast cancer and normal imaging findings in one breast (BI-RADS 1), whose cases were retrospectively analyzed. All patients underwent prone 18F-FDG PET/CT and 3-T contrast-enhanced MRI of the breast. In all patients, interpreter 1 assessed BPU quantitatively using SUVmax Interpreters 1 and 2 assessed amount of FGT and BPE in the normal contralateral breast by subjective visual estimation, as recommended by BI-RADS. Interpreter 1 reassessed all cases and repeated the BPU measurements. Statistical tests were used to assess correlations between BPU, BPE, FGT, and age, as well as inter- and intrainterpreter agreement. RESULTS BPU on 18F-FDG PET/CT varied among patients. The mean BPU SUVmax ± SD was 1.57 ± 0.6 for patients with minimal BPE, 1.93 ± 0.6 for mild BPE, 2.42 ± 0.5 for moderate BPE, and 1.45 ± 0.3 for marked BPE. There were significant (P < 0.001) moderate to strong correlations among BPU, BPE, and FGT. BPU directly correlated with both BPE and FGT on MRI. Patient age showed a moderate to strong indirect correlation with all 3 imaging-derived tissue biomarkers. The coefficient of variation for quantitative BPU measurements with SUVmax was 5.6%, indicating a high reproducibility. Interinterpreter and intrainterpreter agreement for BPE and FGT was almost perfect, with a κ-value of 0.860 and 0.822, respectively. CONCLUSION The results of our study demonstrate that BPU varied among patients. BPU directly correlated with both BPE and FGT on MRI, and BPU measurements were highly reproducible. Patient age showed a strong inverse correlation with all 3 imaging-derived tissue biomarkers. These findings indicate that BPU may serve as a sensitive imaging biomarker for breast cancer prediction, prognosis, and risk assessment.
Collapse
Affiliation(s)
- Doris Leithner
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany; and
| | - Pascal A Baltzer
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria
| | - Heinrich F Magometschnigg
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria
| | - Georg J Wengert
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria
| | - Georgios Karanikas
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria
| | - Thomas H Helbich
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria
| | - Michael Weber
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Wadsak
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria
| | - Katja Pinker
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
17
|
Mastografía por emisión de positrones: revisión de un promisorio instrumento diagnóstico. GACETA MEXICANA DE ONCOLOGÍA 2016. [DOI: 10.1016/j.gamo.2016.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
18
|
Role of Multidetector Computed Tomography in Evaluating Incidentally Detected Breast Lesions. TUMORI JOURNAL 2015; 101:455-60. [DOI: 10.5301/tj.5000291] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/13/2014] [Indexed: 11/20/2022]
Abstract
Aims and Background Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Methods and Study design Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Results Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. Conclusions MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.
Collapse
|
19
|
Vercher-Conejero JL, Pelegrí-Martinez L, Lopez-Aznar D, Cózar-Santiago MDP. Positron Emission Tomography in Breast Cancer. Diagnostics (Basel) 2015; 5:61-83. [PMID: 26854143 PMCID: PMC4665546 DOI: 10.3390/diagnostics5010061] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Revised: 03/03/2015] [Accepted: 03/04/2015] [Indexed: 12/26/2022] Open
Abstract
Gradually, FDG-PET/CT has been strengthening within the diagnostic algorithms of oncological diseases. In many of these, PET/CT has shown to be useful at different stages of the disease: diagnosis, staging or re-staging, treatment response assessment, and recurrence. Some of the advantages of this imaging modality versus CT, MRI, bone scan, mammography, or ultrasound, are based on its great diagnostic capacity since, according to the radiopharmaceutical used, it reflects metabolic changes that often occur before morphological changes and therefore allows us to stage at diagnosis. Moreover, another advantage of this technique is that it allows us to evaluate the whole body so it can be very useful for the detection of distant disease. With regard to breast cancer, FDG-PET/CT has proven to be important when recurrence is suspected or in the evaluation of treatment response. The technological advancement of PET equipment through the development of new detectors and equipment designed specifically for breast imaging, and the development of more specific radiopharmaceuticals for the study of the different biological processes of breast cancer, will allow progress not only in making the diagnosis of the disease at an early stage but also in enabling personalized therapy for patients with breast cancer.
Collapse
Affiliation(s)
- Jose Luis Vercher-Conejero
- Clinical Area of Medical Imaging, Department of Nuclear Medicine, GIBI230, Polytechnic and University Hospital La Fe, Valencia 46026, Spain.
| | - Laura Pelegrí-Martinez
- Diagnostic Imaging, Sant Joan Despí Moisès Broggi Hospital, Sant Joan Despí, Barcelona 08970, Spain.
| | - Diego Lopez-Aznar
- Department of Nuclear Medicine, Provincial Hospital Consortium, Castellón de la Plana 12002, Spain.
| | | |
Collapse
|
20
|
Choudhery S, Seiler S. Positron Emission Mammography Imaging with Low Activity Fluorodeoxyglucose and Novel Utilization in Core-needle Biopsy Sampling. World J Nucl Med 2015; 14:63-5. [PMID: 25709550 PMCID: PMC4337013 DOI: 10.4103/1450-1147.150557] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Positron emission mammography (PEM), a relatively novel breast imaging modality, provides certain advantages over magnetic resonance imaging, including the ability to image biopsy samples. However, the radiation activity associated with PEM has remained a concern in clinical practice. We present a case of an invasive ductal carcinoma that was adequately imaged with a much lower than the standard 185 to 370 MBq activity of (18)F-fluorodeoxyglucose. In addition, we demonstrate ultrasound-guided core-needle biopsy sample imaging with PEM to assess adequacy of sampling, a strategy that has previously only been documented with vacuum-assisted biopsy samples.
Collapse
Affiliation(s)
- Sadia Choudhery
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, Tx 75390, USA
| | - Stephen Seiler
- Department of Radiology, UT Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, Tx 75390, USA
| |
Collapse
|
21
|
Greene LR, Wilkinson D. The role of general nuclear medicine in breast cancer. J Med Radiat Sci 2015; 62:54-65. [PMID: 26229668 PMCID: PMC4364807 DOI: 10.1002/jmrs.97] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2014] [Revised: 01/08/2015] [Accepted: 01/14/2015] [Indexed: 12/12/2022] Open
Abstract
The rising incidence of breast cancer worldwide has prompted many improvements to current care. Routine nuclear medicine is a major contributor to a full gamut of clinical studies such as early lesion detection and stratification; guiding, monitoring, and predicting response to therapy; and monitoring progression, recurrence or metastases. Developments in instrumentation such as the high-resolution dedicated breast device coupled with the diagnostic versatility of conventional cameras have reinserted nuclear medicine as a valuable tool in the broader clinical setting. This review outlines the role of general nuclear medicine, concluding that targeted radiopharmaceuticals and versatile instrumentation position nuclear medicine as a powerful modality for patients with breast cancer.
Collapse
Affiliation(s)
- Lacey R Greene
- Faculty of Science, Charles Sturt University Wagga Wagga, New South Wales, Australia
| | - Deborah Wilkinson
- Faculty of Health, Wheeling Jesuit University Wheeling, West Virginia
| |
Collapse
|
22
|
Hildebrandt MG, Kodahl AR, Teilmann-Jørgensen D, Mogensen O, Jensen PT. [18F]Fluorodeoxyglucose PET/Computed Tomography in Breast Cancer and Gynecologic Cancers. PET Clin 2015; 10:89-104. [DOI: 10.1016/j.cpet.2014.09.007] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
23
|
Alcantara D, Leal MP, García-Bocanegra I, García-Martín ML. Molecular imaging of breast cancer: present and future directions. Front Chem 2014; 2:112. [PMID: 25566530 PMCID: PMC4270251 DOI: 10.3389/fchem.2014.00112] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Accepted: 12/01/2014] [Indexed: 12/21/2022] Open
Abstract
Medical imaging technologies have undergone explosive growth over the past few decades and now play a central role in clinical oncology. But the truly transformative power of imaging in the clinical management of cancer patients lies ahead. Today, imaging is at a crossroads, with molecularly targeted imaging agents expected to broadly expand the capabilities of conventional anatomical imaging methods. Molecular imaging will allow clinicians to not only see where a tumor is located in the body, but also to visualize the expression and activity of specific molecules (e.g., proteases and protein kinases) and biological processes (e.g., apoptosis, angiogenesis, and metastasis) that influence tumor behavior and/or response to therapy. Breast cancer, the most common cancer among women and a research area where our group is actively involved, is a very heterogeneous disease with diverse patterns of development and response to treatment. Hence, molecular imaging is expected to have a major impact on this type of cancer, leading to important improvements in diagnosis, individualized treatment, and drug development, as well as our understanding of how breast cancer arises.
Collapse
Affiliation(s)
- David Alcantara
- Laboratory of Metabolomics and Molecular Imaging, BIONAND, Centro Andaluz de Nanomedicina y Biotecnología (Junta de Andalucía, Universidad de Málaga) Malaga, Spain
| | - Manuel Pernia Leal
- Laboratory of Metabolomics and Molecular Imaging, BIONAND, Centro Andaluz de Nanomedicina y Biotecnología (Junta de Andalucía, Universidad de Málaga) Malaga, Spain
| | - Irene García-Bocanegra
- Laboratory of Metabolomics and Molecular Imaging, BIONAND, Centro Andaluz de Nanomedicina y Biotecnología (Junta de Andalucía, Universidad de Málaga) Malaga, Spain
| | - Maria L García-Martín
- Laboratory of Metabolomics and Molecular Imaging, BIONAND, Centro Andaluz de Nanomedicina y Biotecnología (Junta de Andalucía, Universidad de Málaga) Malaga, Spain
| |
Collapse
|
24
|
Pinker K, Helbich TH, Magometschnigg H, Fueger B, Baltzer P. [Molecular breast imaging. An update]. Radiologe 2014; 54:241-53. [PMID: 24557495 DOI: 10.1007/s00117-013-2580-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
CLINICAL/METHODICAL ISSUE The aim of molecular imaging is to visualize and quantify biological, physiological and pathological processes at cellular and molecular levels. Molecular imaging using various techniques has recently become established in breast imaging. STANDARD RADIOLOGICAL METHODS Currently molecular imaging techniques comprise multiparametric magnetic resonance imaging (MRI) using dynamic contrast-enhanced MRI (DCE-MRI), diffusion-weighted imaging (DWI), proton MR spectroscopy ((1)H-MRSI), nuclear imaging by breast-specific gamma imaging (BSGI), positron emission tomography (PET) and positron emission mammography (PEM) and combinations of techniques (e.g. PET-CT and multiparametric PET-MRI). METHODICAL INNOVATIONS Recently, novel techniques for molecular imaging of breast tumors, such as sodium imaging ((23)Na-MRI), phosphorus spectroscopy ((31)P-MRSI) and hyperpolarized MRI as well as specific radiotracers have been developed and are currently under investigation. PRACTICAL RECOMMENDATIONS It can be expected that molecular imaging of breast tumors will enable a simultaneous assessment of the multiple metabolic and molecular processes involved in cancer development and thus an improved detection, characterization, staging and monitoring of response to treatment will become possible.
Collapse
Affiliation(s)
- K Pinker
- Abteilung für Molekulare Bildgebung, Universitätsklinik für Radiologie und Nuklearmedizin, Medizinische Universität Wien, Währinger Gürtel 18-20, 1090, Wien, Österreich
| | | | | | | | | |
Collapse
|
25
|
Fluorodeoxyglucose Positron Emission Tomography With Computed Tomography Detects Greater Metabolic Changes That Are Not Represented by Plain Radiography for Patients With Osteonecrosis of the Jaw. J Oral Maxillofac Surg 2014; 72:1957-65. [DOI: 10.1016/j.joms.2014.04.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2013] [Revised: 04/08/2014] [Accepted: 04/12/2014] [Indexed: 12/17/2022]
|
26
|
Caldarella C, Treglia G, Giordano A. Diagnostic Performance of Dedicated Positron Emission Mammography Using Fluorine-18-Fluorodeoxyglucose in Women With Suspicious Breast Lesions: A Meta-analysis. Clin Breast Cancer 2014; 14:241-8. [DOI: 10.1016/j.clbc.2013.12.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2013] [Revised: 12/12/2013] [Accepted: 12/23/2013] [Indexed: 10/25/2022]
|
27
|
Correlation of PUV and SUV in the extremities while using PEM as a high-resolution positron emission scanner. Skeletal Radiol 2014; 43:453-8. [PMID: 24430256 PMCID: PMC4086781 DOI: 10.1007/s00256-013-1795-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Revised: 11/23/2013] [Accepted: 12/01/2013] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Owing to its unique configuration of two adjustable plate detectors positron emission mammography, or PEM, could theoretically also function as a high-resolution positron emission scanner for the extremities or neck. PEM quantitates its activity via a "PEM uptake value," or PUV, and although its relationship to the standardized uptake value, or SUV, has been demonstrated in the breasts, to our knowledge there are no studies validating PUV in other sites such as the extremities. MATERIALS AND METHODS This was a retrospective chart review of two separate protocols of a total of 15 patients. The patients all had hypermetabolic lesions in the extremities or neck on imaging with PET/CT and were sent after their PET/CT to PEM for further imaging. Owing to the sequential nature of these examinations no additional radiotracer was administered. RESULTS Spearman's rank order correlation was calculated between the PUVmax obtained from PEM images, and the SUVmax for all. Spearman's rank order correlation for all sites was 0.42, which is not significantly different from 0 (p = 0.13). When neck lesions were excluded from the group, there was a strong and statistically significant correlation between PUVmax and SUVmax, with Spearman's rank correlation of 0.73, and significantly different from 0 (p = 0.0068). DISCUSSION The correlation of PUV and SUV in the extremities indicates the potential use of PEM as a semiquantitative, high-resolution positron emission scanner and warrants further investigation, especially in the realms of disease processes that often present in the extremities, such as melanoma, osteomyelitis, and arthritis, as well as playing a role in the imaging of patients with metallic hardware post-limb salvage surgery.
Collapse
|
28
|
Magometschnigg HF, Helbich T, Brader P, Abeyakoon O, Baltzer P, Füger B, Wengert G, Polanec S, Bickel H, Pinker K. Molecular imaging for the characterization of breast tumors. Expert Rev Anticancer Ther 2014; 14:711-22. [DOI: 10.1586/14737140.2014.885383] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
29
|
Is imaging the extremities with PEM feasible? A novel application for a high-resolution positron emission scanner. Clin Imaging 2013; 38:307-13. [PMID: 24485528 DOI: 10.1016/j.clinimag.2013.11.013] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2013] [Revised: 11/13/2013] [Accepted: 11/16/2013] [Indexed: 11/23/2022]
Abstract
INTRODUCTION Positron emission mammography (PEM) has better spatial resolution than positron emission tomography/computed tomography (PET/CT), or PET/CT. We evaluated the feasibility of extremity imaging with PEM using PET as a standard. METHODS/MATERIALS Fourteen patients underwent sequential PET/CT and PEM. RESULTS/DISCUSSION PEM visualized with equal or improved resolution all of the lesions identified on PET/CT. It often provided additional information such improved uptake localization and also visualized activity in an adjacent structures that was not seen on PET/CT or magnetic resonance imaging. We believe PEM can image the extremities in diseases like melanoma, arthritis and osteomyelitis and patients with metallic hardware.
Collapse
|