1
|
Elghadban H, Mahmoud A, Negm A, Dawoud IES, Taki-Eldin A. Evaluation of Safety and Feasibility of Using LigaSure During Clipless Single-Incision Laparoscopic Cholecystectomy: A Prospective Clinical Study. J Laparoendosc Adv Surg Tech A 2024; 34:1000-1006. [PMID: 39083433 DOI: 10.1089/lap.2024.0157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/02/2024] Open
Abstract
Background: Single-incision laparoscopic cholecystectomy (SILC) is a minimally invasive procedure designed to minimize the number and size of the incisions needed for cholecystectomy. Titanium clips are traditionally used to close the cystic duct and artery. Although it is considered safe, dislodgement can result in bleeding and biliary leakage. Using LigaSure for duct sealing is still controversial. The aim of this study was to evaluate the safety and feasibility of using LigaSure to close the cystic duct during SILC. Methods: A prospective study over two years was conducted at the General Surgery Department, Mansoura University Hospital, on 102 patients, 51 in each group. They underwent SILC using LigaSure (Group 1) or titanium clips (Group 2) to control the cystic duct and artery. Results: The data analyzed included demographic data, operative time, intra- and postoperative complications, postoperative pain, and hospital stay. The operative time was significantly shorter in LigaSure group (68.5 ± 9.8 versus 72.9 ± 10.6 minutes in the clips group, P .03). There was no significant difference between the two groups regarding postoperative bile leak or bleeding. However, two cases in Group 1 and four cases in Group 2 were converted to multiple port laparoscopic cholecystectomy; this was statistically nonsignificant. Postoperative pain and hospital stay showed no significant difference between the two groups. Two patients in each group developed port-site incisional hernia. Conclusions: Clipless SILC using LigaSure is a feasible and safe procedure with acceptable morbidity with shorter operative time than SILC using clips. Nevertheless, the risk of port-site incisional hernia should be explained to the patients.
Collapse
Affiliation(s)
- Hosam Elghadban
- General Surgery Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Abdallah Mahmoud
- General Surgery Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Ahmed Negm
- General Surgery Department, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | | | - Ahmed Taki-Eldin
- General Surgery Department, Faculty of Medicine, Horus University-Egypt, New Damietta, Egypt
| |
Collapse
|
2
|
Montori G, Botteri E, Ortenzi M, Gerardi C, Allocati E, Giordano A, Vettoretto N, Arezzo A, Huo B, Bergamini C, Podda M, Agresta F. Systematic review and meta-analysis of the use of high-energy devices for thyroid surgery. Langenbecks Arch Surg 2024; 409:217. [PMID: 39017727 DOI: 10.1007/s00423-024-03399-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Accepted: 06/26/2024] [Indexed: 07/18/2024]
Abstract
BACKGROUND We conducted a systematic review and meta-analysis to evaluate the role of High Energy Devices (HEDs) versus conventional clamp and tie technique in thyroidectomy. This work is endorsed by the Italian Society of Surgical Endoscopy (Italian Society of Endoscopic Surgery and new technologies-SICE) in the broader project on the evaluation of the role of HEDs in different surgical settings with the full health technology assessment report. MEHODS Inclusion criteria were adult patients (≥ 18 years old) undergoing Thyroidectomy/Parathyroidectomy conducted with High Energy Devices (as ultrasonic (US), radiofrequency (RF), and hybrid energy (H-US/RF)) in the setting of thyroid surgery (both partial and total) for benign and malign diseases. However, some variability was found in included studies and described in the text. This systematic review and meta-analysis were performed according to the Cochrane handbook for systematic reviews, and the recommendations of the 2020 updated Preferred Reporting Items for Systematic reviews and Meta-analyses (PRISMA) guidelines were pursuit. Selection of abstracts was performed in Ryyan system by 2 independent reviewers, and doubts were solved by another independent reviewer. At the end of literature research, Randomized controlled trials and observational studies were included. Risk of Bias was assessed with ROB2 for RCTs, and New Castle Ottawa Scale for Observational studies. RESULTS The literature search yielded 47 studies, including 29 RCTs and 18 observational studies. Meta-analysis was performed for 29 randomized clinical trials. Outcomes included in the comparison between High Energy Devise and conventional technique groups were operative time, operative blood loss, overall post-operative drainage volume, length of stay, complications, and costs. HED significantly reduced operative time (28 studies, 3097patients; MD -128.8; 95% CI -34.4 to -23.20; I2 = 96%, p < 0.00001, Random-effect), intra-operative blood loss (13 studies, 642 vs 519 patients; SMD -0.82; 95% CI -1.33 to -0.32; I2 = 93%, p < 0.00001, Random-effect), LOS (22 studies, 2808 vs 2789 patients; MD -0.38, 95% CI -0.59 to -0.17; I2 = 98%, p < 0.00001 Random-effect), and healthcare costs (8 studies, 1138 vs 1129 patients, SMD 1.05; 95% CI -0.06 to 2.16; I2 = 99%, p < 0.00001 Random-effect). The rate of overall intraoperative complications was significantly different between both groups (25 studies, 2804 vs 2775 patients; RR 0.88, 95% CI 0.80 to 0.97; I2 = 38%, p = 0.03 Random-effect), but the sensitivity analysis did not find a statistically significant difference (6 studies, 605 vs 594 patients, RR; 95% CI to; I2 = 0%, p = 0.50, Random-effect). There was no difference in the subgroup analysis for the occurrence of transient and permanent RLN palsy, nor hematoma formation and hypocalcaemia. DISCUSSION Though findings of our systematic review and metanalysis are limited by heterogeneous data, surgeons, hospital managers, and policymakers should note that the use of High Energy Devices compared to conventional clamp and tie technique have reduced operative times, intra-operative blood loss, length of stay, and hospital costs in patients underwent to tyroid surgery. Future work must explore issues of equity to mitigate barriers to patient access to safe thyroid surgical care and define better this initial results.
Collapse
Affiliation(s)
- Giulia Montori
- Department of General and Emergency Surgery, Vittorio Veneto Hospital, Vittorio Veneto (Treviso), Italy.
| | - Emanuele Botteri
- General Surgery, ASST Spedali Civili Di Brescia PO Montichiari, Brescia, Montichiari, Italy
| | - Monica Ortenzi
- Department of General Surgery, Università Politecnica Delle Marche, Piazza Roma 22, 60121, Ancona, Italy
| | - Chiara Gerardi
- Istituto Di Ricerche Farmacologiche Mario Negri IRCCS, Milan, Italy
| | | | - Alessio Giordano
- Department of Emergency, Emergency General Surgery Unit, AOU Careggi, Florence, Italy
| | - Nereo Vettoretto
- General Surgery, ASST Spedali Civili Di Brescia PO Montichiari, Brescia, Montichiari, Italy
| | - Alberto Arezzo
- Department of Surgical Sciences, University of Torino, Turin, Italy
| | - Bright Huo
- Division of General Surgery, Department of Surgery, Ma, Hamilton, Canada
| | - Carlo Bergamini
- Department of Emergency, Emergency General Surgery Unit, AOU Careggi, Florence, Italy
| | - Mauro Podda
- Department of Surgical Science, Emergency Surgery Unit, University of Cagliari, Cagliari, Italy
| | - Ferdinando Agresta
- Department of General and Emergency Surgery, Vittorio Veneto Hospital, Vittorio Veneto (Treviso), Italy
| |
Collapse
|
3
|
Vettoretto N, Foglia E, Gerardi C, Lettieri E, Nocco U, Botteri E, Bracale U, Caracino V, Carrano FM, Cassinotti E, Giovenzana M, Giuliani B, Iossa A, Milone M, Montori G, Peltrini R, Piatto G, Podda M, Sartori A, Allocati E, Ferrario L, Asperti F, Songia L, Garattini S, Agresta F. High-energy devices in different surgical settings: lessons learnt from a full health technology assessment report developed by SICE (Società Italiana di Chirurgia Endoscopica). Surg Endosc 2023; 37:2548-2565. [PMID: 36333498 PMCID: PMC9638482 DOI: 10.1007/s00464-022-09734-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 10/11/2022] [Indexed: 11/06/2022]
Abstract
BACKGROUND The present paper aims at evaluating the potential benefits of high-energy devices (HEDs) in the Italian surgical practice, defining the comparative efficacy and safety profiles, as well as the potential economic and organizational advantages for hospitals and patients, with respect to standard monopolar or bipolar devices. METHODS A Health Technology Assessment was conducted in 2021 assuming the hospital perspective, comparing HEDs and standard monopolar/bipolar devices, within eleven surgical settings: appendectomy, hepatic resections, colorectal resections, cholecystectomy, splenectomy, hemorrhoidectomy, thyroidectomy, esophago-gastrectomy, breast surgery, adrenalectomy, and pancreatectomy. The nine EUnetHTA Core Model dimensions were deployed considering a multi-methods approach. Both qualitative and quantitative methods were used: (1) a systematic literature review for the definition of the comparative efficacy and safety data; (2) administration of qualitative questionnaires, completed by 23 healthcare professionals (according to 7-item Likert scale, ranging from - 3 to + 3); and (3) health-economics tools, useful for the economic evaluation of the clinical pathway and budget impact analysis, and for the definition of the organizational and accessibility advantages, in terms of time or procedures' savings. RESULTS The literature declared a decrease in operating time and length of stay in using HEDs in most surgical settings. While HEDs would lead to a marginal investment for the conduction of 178,619 surgeries on annual basis, their routinely implementation would generate significant organizational savings. A decrease equal to - 5.25/-9.02% of operating room time and to - 5.03/-30.73% of length of stay emerged. An advantage in accessibility to surgery could be hypothesized in a 9% of increase, due to the gaining in operatory slots. Professionals' perceptions crystallized and confirmed literature evidence, declaring a better safety and effectiveness profile. An improvement in both patients and caregivers' quality-of-life emerged. CONCLUSIONS The results have demonstrated the strategic relevance related to HEDs introduction, their economic sustainability, and feasibility, as well as the potentialities in process improvement.
Collapse
Affiliation(s)
- Nereo Vettoretto
- U.O.C. Chirurgia Generale, ASST Spedali Civili di Brescia P.O. Montichiari, Ospedale di Montichiari, Chirurgia, V.le Ciotti 154, 25018, Montichiari, BS, Italy.
| | - Emanuela Foglia
- Centre for Health Economics, Social and Health Care Management, Università Carlo Cattaneo - LIUC, Castellanza, Italy
| | - Chiara Gerardi
- Mario Negri Institute for Pharmacological Research IRCCS, Milan, Italy
| | - Emanuele Lettieri
- Dipartimento di Ingegneria Gestionale, Politecnico di Milano, Milan, Italy
| | - Umberto Nocco
- S.C. Ingegneria Clinica, ASST Grande Ospedale Metropolitano Niguarda and Associazione Italiana Ingegneri Clinici, Milan, Italy
| | - Emanuele Botteri
- U.O.C. Chirurgia Generale, ASST Spedali Civili di Brescia P.O. Montichiari, Ospedale di Montichiari, Chirurgia, V.le Ciotti 154, 25018, Montichiari, BS, Italy
| | - Umberto Bracale
- U.O.C. Chirurgie Generale e Oncologica Mini Invasiva, A.O.U. Policlinico Federico II, Naples, Italy
| | - Valerio Caracino
- U.O.C. Chirurgia Generale e d'Urgenza, AUSL Pescara, Pescara, Italy
| | | | - Elisa Cassinotti
- Chirurgia Generale, Fondazione IRCCS Ca' Granda - Ospedale Maggiore Policlinico, Milan, Italy
| | - Marco Giovenzana
- Unit of HepatoBilioPancreatic and Digestive Surgery, Ospedale San Paolo, University of Milan, Milan, Italy
| | - Beatrice Giuliani
- Unit of HepatoBilioPancreatic and Digestive Surgery, Ospedale San Paolo, University of Milan, Milan, Italy
| | - Angelo Iossa
- Department of Medico-Surgical Sciences and Biotechnologies, Faculty of Pharmacy and Medicine, University of Rome Sapienza Polo Pontino, Rome, Italy
| | - Marco Milone
- U.O.C. Chirurgia Generale, Azienda Ospedaliera Universitaria Federico II di Napoli, Naples, Italy
| | - Giulia Montori
- U.O.C. Chirurgia Generale, Ospedale di Vittorio Veneto, Treviso, Italy
| | - Roberto Peltrini
- U.O.C. Chirurgie Generale e Oncologica Mini Invasiva, A.O.U. Policlinico Federico II, Naples, Italy
| | - Giacomo Piatto
- UOC Chirurgia Generale e d'Urgenza, Ospedale di Montebelluna (TV), AULSS 2 Marca Trevigiana, Treviso, Italy
| | - Mauro Podda
- Dipartimento di Scienze Chirurgiche, Università degli Studi di Cagliari, Cagliari, Italy
| | - Alberto Sartori
- UOC Chirurgia Generale e d'Urgenza, Ospedale di Montebelluna (TV), AULSS 2 Marca Trevigiana, Treviso, Italy
| | - Eleonora Allocati
- Mario Negri Institute for Pharmacological Research IRCCS, Milan, Italy
| | - Lucrezia Ferrario
- Centre for Health Economics, Social and Health Care Management, Università Carlo Cattaneo - LIUC, Castellanza, Italy
| | - Federica Asperti
- Centre for Health Economics, Social and Health Care Management, Università Carlo Cattaneo - LIUC, Castellanza, Italy
| | - Letizia Songia
- S.C. Ingegneria Clinica, ASST Grande Ospedale Metropolitano Niguarda and Associazione Italiana Ingegneri Clinici, Milan, Italy
- SC Ingengeria Clinica, ASST di Lecco, Lecco, Italy
| | - Silvio Garattini
- Centre for Health Economics, Social and Health Care Management, Università Carlo Cattaneo - LIUC, Castellanza, Italy
| | | |
Collapse
|
4
|
Spartalis E, Giannakodimos A, Giannakodimos I, Ziogou A, Papasilekas T, Patelis N, Schizas D, Troupis T. The role of LigaSure™ and Harmonic Scalpel in the preservation of recurrent laryngeal nerve during thyroidectomy. Ann R Coll Surg Engl 2021; 104:324-329. [PMID: 34415202 DOI: 10.1308/rcsann.2021.0125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
INTRODUCTION Transient or permanent damage to the recurrent laryngeal nerve (RLN) during thyroidectomy is of paramount importance for patient quality of life. The aim of this study is to systematically review the literature concerning the role of the most popular energy-based vessel-sealing devices (LigaSure™ (LS) and Harmonic Scalpel (HS)) in preservation of the RLN during thyroidectomy. The safety and inferiority or superiority of LS and HS compared with conventional haemostatic techniques are highlighted. METHODS A systematic search of the literature was performed. Clinical trials, prospective and retrospective studies that significantly compared the use of LS and HS with conventional haemostasis regarding the postoperative incidence of RLN palsy were included. FINDINGS The search resulted in 43 studies, including 17,953 patients treated using energy-based devices or conventional haemostatic methods. Concerning the incidence of RLN palsy, 40 studies showed no significant difference between the energy-based device and conventional groups, whereas two studies demonstrated a significant superiority in performance for LS and HS compared with conventional haemostasis. Only one study exhibited significant inferiority of LS and HS compared with conventional methods. No statistical relationship was observed between energy-based devices and conventional techniques regarding permanent damage to the RLN. CONCLUSION The performance of both LS and HS shows no inferiority compared with conventional haemostatic techniques, regarding damage to the laryngeal nerve. Further well-designed studies are needed to investigate their potential benefit in preservation of the RLN.
Collapse
Affiliation(s)
- E Spartalis
- National and Kapodistrian University of Athens, Greece
| | | | | | - A Ziogou
- National and Kapodistrian University of Athens, Greece
| | - T Papasilekas
- National and Kapodistrian University of Athens, Greece
| | - N Patelis
- National and Kapodistrian University of Athens, Greece
| | - D Schizas
- National and Kapodistrian University of Athens, Greece
| | - T Troupis
- National and Kapodistrian University of Athens, Greece
| |
Collapse
|
5
|
Spartalis E, Giannakodimos A, Ziogou A, Giannakodimos I, Paschou SA, Spartalis M, Schizas D, Troupis T. Effect of energy-based devices on post-operative parathyroid function and blood calcium levels after total thyroidectomy. Expert Rev Med Devices 2021; 18:291-298. [PMID: 33666537 DOI: 10.1080/17434440.2021.1899805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
Introduction: Energy-based devices are widely used in thyroid surgery in order to achieve optimal hemostasis, while their role in the incidence of hypocalcemia and hypoparathyroidism comprises a topic evaluated in numerous studies.Areas covered: The aim of this systematic review is to investigate the potential benefit of Ultrasonic Shears and Electrothermal Bipolar (Radiofrequency) System in thyroid surgery regarding the incidence of post-operative hypocalcemia and hypoparathyroidism. A systematic review of the literature in PubMed/Medline and Scopus databases was conducted. Forty-nine studies met the inclusion criteria and were analyzed. A statistically decreased rate of transient hypocalcemia and hypoparathyroidism was reported in 15 studies and 4 studies, respectively, when using energy-based devices. However, 18 and 13 surveys examined transient hypocalcemia and hypoparathyroidism, respectively, and demonstrated no statistical difference between energy-based devices and conventional hemostasis. No difference was observed between the groups concerning permanent hypocalcemia. Out of 13 studies, only 2 showed a significant reduction in the occurrence of permanent hypoparathyroidism in the energy-based device group.Expert opinion: Energy-based devices reduced the rate of transient hypocalcemia and hypoparathyroidism after thyroid surgeries in 42.8% and 23.5% of the included studies, respectively. Further studies are needed to evaluate their impact on permanent post-operative hypocalcemia and hypoparathyroidism.
Collapse
Affiliation(s)
- Eleftherios Spartalis
- 2nd Department of Propaedeutic Surgery, National and Kapodistrian University of Athens, Medical School, Athens, Greece
- Laboratory of Experimental Surgery and Surgical Research "N.S Christeas," National and Kapodistrian University of Athens, Medical School, Athens, Greece
- Department of Anatomy, Medical School, National and Kapodistrian University of Athens, Medical School, Athens, Greece
| | - Alexios Giannakodimos
- 2 Department of Propaedeutic Surgery, National and Kapodistrian University of Athens, Medical School, Athens, Greece
| | - Afroditi Ziogou
- Third Department of Surgery, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Ilias Giannakodimos
- 1st Department of Surgery, National and Kapodistrian University of Athens, Athens, Greece
| | - Stavroula A Paschou
- Division of Endocrinology, Diabetes and Metabolism, Department of Clinical Therapeutics, Alexandra Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
| | - Michael Spartalis
- Laboratory of Experimental Surgery and Surgical Research "N.S Christeas," National and Kapodistrian University of Athens, Medical School, Athens, Greece
| | - Dimitrios Schizas
- 1st Department of Surgery, National and Kapodistrian University of Athens, Athens, Greece
| | - Theodore Troupis
- Department of Anatomy, Medical School, National and Kapodistrian University of Athens, Medical School, Athens, Greece
| |
Collapse
|
6
|
Liu CH, Wang CC, Wu CW, Lin YC, Lu IC, Chang PY, Lien CF, Wang CC, Hwang TZ, Huang TY, Chiang FY. Comparison of Surgical Complications Rates Between LigaSure Small Jaw and Clamp-and-Tie Hemostatic Technique in 1,000 Neuro-Monitored Thyroidectomies. Front Endocrinol (Lausanne) 2021; 12:638608. [PMID: 33897619 PMCID: PMC8058413 DOI: 10.3389/fendo.2021.638608] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 03/15/2021] [Indexed: 01/27/2023] Open
Abstract
Over the past decade, the use of neuromonitoring in thyroid surgery has become well established and is increasing accepted across the world. In addition, new developments in energy devices have significantly improved efficacy in achieving hemostasis in thyroid surgery. Few studies focused on the complication rates in energy device-assisted sutureless neuro-monitored thyroidectomy. This study investigates a novel LigaSure Small Jaw (LSJ) technique for sutureless thyroidectomy and compares the surgical complication rates between LSJ and conventional clamp-and-tie technique in one thousand consecutive neuro-monitored thyroidectomy patients. Five hundred patients received sutureless thyroidectomy performed with LSJ (Group L), and 500 patients received surgery performed with conventional clamp-and-tie technique (Group C). Complication rates of postoperative hematoma, hypocalcemia and recurrent laryngeal nerve (RLN) palsy were compared between groups. The overall complication rates of hematoma, hypocalcemia (temporary/ permanent), and RLN (temporary/ permanent) palsy were 0.9%, 24.9% (24.6%/0.3%), and 1.7% (1.5%/0.2%), respectively. Group L and Group C significantly differed in postoperative hematoma rate (0.0% vs. 1.8%, respectively; p = 0.0026) and in postoperative hypocalcemia rate (20.1% vs. 30.0%, respectively; p = 0.0032). The incidence of RLN palsy did not significantly differ between Group L and Group C (1.38% vs. 2.08%; p = 0.2652). The overall surgical complication rates are low in neuro-monitored thyroidectomy. The LSJ is feasible for performing completely sutureless thyroidectomy and obtains superior outcomes of postoperative hematoma and hypocalcemia in comparison with clamp-and-tie hemostatic technique. The novel LSJ technique using double or overlapped sealing is useful for sutureless thyroidectomy. However, surgeons must carefully observe the tissue contraction that may reduce the LSJ-RLN distance and increase the risk of thermal injury during the LSJ activation.
Collapse
Affiliation(s)
- Cheng-Hsin Liu
- International Thyroid Surgery Center, Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Chih-Chun Wang
- Department of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan
| | - Che-Wei Wu
- International Thyroid Surgery Center, Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Yi-Chu Lin
- International Thyroid Surgery Center, Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - I-Cheng Lu
- Department of Anesthesiology, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Pi-Ying Chang
- Department of Anesthesiology, Kaohsiung Municipal Ta-Tung Hospital, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Ching-Feng Lien
- Department of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan
| | - Chien-Chung Wang
- Department of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan
| | - Tzer-Zen Hwang
- Department of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan
| | - Tzu-Yen Huang
- International Thyroid Surgery Center, Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Biological Science and Technology, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
- *Correspondence: Feng-Yu Chiang, ; Tzu-Yen Huang,
| | - Feng-Yu Chiang
- Department of Otolaryngology-Head and Neck Surgery, E-Da Hospital, Kaohsiung, Taiwan
- School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan
- *Correspondence: Feng-Yu Chiang, ; Tzu-Yen Huang,
| |
Collapse
|
7
|
Chiang FY, Lee KD, Tae K, Tufano RP, Wu CW, Lu IC, Chang PY, Lin YC, Huang TY. Comparison of hypocalcemia rates between LigaSure and clamp-and-tie hemostatic technique in total thyroidectomies. Head Neck 2019; 41:3677-3683. [PMID: 31347742 DOI: 10.1002/hed.25884] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Revised: 06/10/2019] [Accepted: 07/11/2019] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Postoperative hypocalcemia (PH) is a serious complication after total thyroidectomy. This study aimed to compare PH rates between LigaSure Small Jaw (LSJ) and clamp-and-tie hemostatic technique in patients undergoing total thyroidectomy. METHODS Four hundred twenty patients were divided into two groups: group L (210 patients) performed with LSJ and group C (210 patients) with clamp-and-tie technique. Serum ionized calcium (iCa) was measured before and 12, 24, 48, 72 hours after surgery. PH was defined as iCa lower than 4.2 mg/dL in at least two measurements. RESULTS There was no significant difference between groups in sex, age, extent of surgery, pathology, and the strategy of intraoperative management of parathyroid glands (PG). The PH rate was significantly lower in group L compared to group C (22.9% vs 32.4%, P = .03). CONCLUSIONS Compared to clamp-and-tie technique, LigaSure is superior to decrease PH rate after total thyroidectomy.
Collapse
Affiliation(s)
- Feng-Yu Chiang
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.,Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Kang Dae Lee
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Kosin University, Busan, South Korea
| | - Kyung Tae
- Department of Otolaryngology-Head and Neck Surgery, College of Medicine, Hanyang University, Seoul, South Korea
| | - Ralph P Tufano
- Department of Otolaryngology-Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Che-Wei Wu
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.,Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - I-Cheng Lu
- Faculty of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.,Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Pi-Ying Chang
- Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Yi-Chu Lin
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Tzu-Yen Huang
- Department of Otolaryngology-Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
8
|
Arowolo OA, Olasehinde O, Adisa AO, Adeyemo A, Alatise OI, Wuraola F. Early Experience with LigaSure Thyroidectomy in a Nigeria Teaching Hospital. Niger J Surg 2019; 25:64-69. [PMID: 31007515 PMCID: PMC6452764 DOI: 10.4103/njs.njs_40_18] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND The principles of safe and efficient thyroid surgery had been established and the technique has remained the same for over the century without any major significant changes. The introductions of electrosurgical devices constitute a major shift in the technique of thyroid surgery. OBJECTIVE We present our early experience with the use of LIGASURE vessel sealing system for the procedure of thyroidectomy. MATERIALS AND METHODS This was a quasi-experimental study comparing outcome of LigaSure thyroidectomy in a prospective nonrandomized cohort with another retrospective cohort of preintervention clamp-and-tie thyroidectomy. RESULTS A total of 30 patients with a clinical diagnosis of goiter were recruited into the study. There were two males and 28 females with a mean age of 42.6 years. Diagnosis was simple multinodular goiter 24 (80%), controlled toxic nodular goiter 3 (10%), grave disease 1 (3.3%), and multinodular goiter with retrosternal extension 2 (6.7%). The mean thyroid weight was 121.0 g. The mean duration of surgery was 59 min compared to 128 min for traditional technique (P < 0.01). The mean blood loss of 116 ml was significantly less than 328 ml following the traditional technique (P < 0.01). Mean duration of hospital stay was 1.9 days, compared to 3.55 days in the traditional technique group (P = 0.02). Troubling postoperative complications of change in voice quality occurred in only one patient (3.3%). CONCLUSION LigaSure thyroidectomy was found to be easier and faster to carry out with no learning curve and easy to learn and adapt.
Collapse
Affiliation(s)
| | - Olalekan Olasehinde
- Department of Surgery, Obafemi Awolowo University, Ile Ife, Osun State, Nigeria
| | | | - Adekunle Adeyemo
- Department of Surgery, Obafemi Awolowo University, Ile Ife, Osun State, Nigeria
| | | | - Funmilola Wuraola
- Department of Surgery, Obafemi Awolowo University Teaching Hospitals Complex, Ile Ife, Osun State, Nigeria
| |
Collapse
|
9
|
Ramouz A, Rasihashemi SZ, Safaeiyan A, Hosseini M. Comparing postoperative complication of LigaSure Small Jaw instrument with clamp and tie method in thyroidectomy patients: a randomized controlled trial [IRCT2014010516077N1]. World J Surg Oncol 2018; 16:154. [PMID: 30236136 PMCID: PMC6148793 DOI: 10.1186/s12957-018-1448-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2018] [Accepted: 07/05/2018] [Indexed: 11/10/2022] Open
Abstract
Background LigaSure® Small Jaw (LSJ) has been recently introduced as an energy-based vessel sealing device, which has provided better intraoperative and postoperative outcomes in thyroidectomies, compared to conventional technique. In the current study, we aimed to examine the efficiency of hand-sewn and LSJ thyroidectomy, based on operation time and perioperative complications. Methods All patients with the diagnosis of multinodular goiter, thyroid cancers, retrosternal goiter and other indications for thyroid surgeries, enrolled. Of 550 patients, 261 patients randomly assigned to the conventional group (A) and 274 patients to LigaSure Small Jaw group (B). Study groups compared concerning operative time, recurrent laryngeal nerve (RLN) injury, hypocalcemia, and postoperative complications. Results There was no significant difference regarding demographic data between groups A and B. During total thyroidectomy, intraoperative blood loss was 64.42 ± 20.72 ml and 49.64 ± 17.92 ml in groups A and B, respectively (P 0.043). Operative time was significantly lower in LSJ group compared to the conventional group in total and subtotal thyroidectomy (P 0.002; P 0.001). Three patients who underwent conventional total thyroidectomy had RLN palsy. However, there was no significant difference between techniques regarding RLN injury (P 0.134). Postoperative total and ionized serum calcium levels decreased compared to preoperative levels in both conventional and LSJ technique; however, changes in total and ionized serum calcium were more severe in patients with conventional thyroidectomy (total calcium, P < 0.0001) (ionized calcium, P 0.005). Conclusion The LigaSure Small Jaw device decreases operative time and intraoperative bleeding compared to conventional technique. Besides, changes in total and ionized calcium levels in patients with LSJ thyroidectomy are subtle compared to HS technique. Trial registration Registered in Iranian Registry of Clinical Trials (www.irct.com), trial registration: IRCT2014010516077N1, Registered: 23 May 2014).
Collapse
Affiliation(s)
- Ali Ramouz
- Department of Cardiothoracic Surgery, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Seyed Ziaeddin Rasihashemi
- Department of Cardiothoracic Surgery, Tabriz University of Medical Sciences, Tabriz, Iran. .,Imam Reza Hospital, Golgasht street, 5183915881, Tabriz, Iran.
| | - Abdolrasoul Safaeiyan
- Department of Vital Statistics and Epidemiology, School of Health, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mahdie Hosseini
- Department of Cardiothoracic Surgery, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
10
|
Trilling B, Riboud R, Abba J, Girard E, Faucheron JL. Energy vessel sealing systems versus mechanical ligature of the inferior mesenteric artery in laparoscopic sigmoidectomy. Int J Colorectal Dis 2016; 31:903-8. [PMID: 26841803 DOI: 10.1007/s00384-016-2508-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/21/2016] [Indexed: 02/04/2023]
Abstract
PURPOSE With the development of new devices, our ligation technique of the inferior mesenteric artery changed from mechanical ligature (ML) to energized vessel sealing systems (EVSS) ligature. The aim of this study was to determine if EVSS could be considered as safe and effective as the more convention ML of the inferior mesenteric vessels division during elective laparoscopic left colectomy. METHODS Between 2001 and 2014, 200 consecutive patients (111 males) of mean age 54.1 years were operated laparoscopically for a symptomatic sigmoid diverticulitis. Vascular interruptions were performed using mechanical ligatures including double clipping, staples or surgical thread (100 patients) or, starting from 2006, with EVSS thereafter (100 patients). Section of the inferior mesenteric artery is performed systematically at its origin in our institution for teaching purposes. Technical results were prospectively collected perioperatively and postoperatively. RESULTS There was no mortality. Mean operating time was 253.7 and 200.7 min in the ML and EVSS groups, respectively (p < 0.001). Mean hospital stay was 10.4 and 8.1 days (p < 0.001). Thirty-day complications occurred in 31 versus 25 % of patients (p = 0.26). Leakage with peritonitis occurred in 3 patients in the ML group. Hemorrhagic events occurred in both groups (2 in ML group versus 1 in EVSS group). Limitations of the study are its retrospective design and the bias due to the comparison of two historical cohorts. CONCLUSIONS EVSS for the inferior mesenteric artery are as safe and effective as ML in elective sigmoidectomy for diverticular disease with lower operative time and hospital stay.
Collapse
Affiliation(s)
- Bertrand Trilling
- Colorectal Unit, Department of Surgery, Michalon University Hospital, CS 10 217, 38 043, Grenoble cedex, France.,Grenoble Alpes University, UMR 5525, CNRS, TIMC-IMAG, Grenoble, France
| | - Romain Riboud
- Colorectal Unit, Department of Surgery, Michalon University Hospital, CS 10 217, 38 043, Grenoble cedex, France.,Visceral Surgery Department, Voiron Regional Hospital, Voiron, France
| | - Julio Abba
- Colorectal Unit, Department of Surgery, Michalon University Hospital, CS 10 217, 38 043, Grenoble cedex, France
| | - Edouard Girard
- Colorectal Unit, Department of Surgery, Michalon University Hospital, CS 10 217, 38 043, Grenoble cedex, France.,Grenoble Alpes University, UMR 5525, CNRS, TIMC-IMAG, Grenoble, France
| | - Jean-Luc Faucheron
- Colorectal Unit, Department of Surgery, Michalon University Hospital, CS 10 217, 38 043, Grenoble cedex, France. .,Grenoble Alpes University, UMR 5525, CNRS, TIMC-IMAG, Grenoble, France.
| |
Collapse
|
11
|
Single incision cholecystectomy using a clipless technique with LigaSure in a resource limited environment: The Bahamas experience. Int J Surg Case Rep 2015; 11:104-109. [PMID: 25958050 PMCID: PMC4446690 DOI: 10.1016/j.ijscr.2015.04.034] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 04/23/2015] [Accepted: 04/23/2015] [Indexed: 01/24/2023] Open
Abstract
SILC in the third world. The addition of LigaSure to enhance procedure. Look at feasibility. Look at cost different.
Background Scarless/single-incision laparoscopic cholecystectomy (SILC) is a new procedure. It affords a superior cosmetic outcome when compared to conventional laparoscopic cholecystectomy. We examine the application of this technique using LigaSure via a clipless method. The present study looks at the experience of a single surgeon using this method with initial evaluation of the safety, feasibility, affordability, and benefits of this procedure. Methods Twenty-eight patients underwent transumbilical SILC at Doctors Hospital from January to December, 2014. The cohort included both emergency and elective patients. There was no difference in the preoperative work-up as indicated. To perform the operation, a 2–2.5-cm linear incision was made through the umbilicus and the single port platform utilized. A 10 mm 30-degree laparoscope, a 5 mm LigaSure and straight instruments were used to perform the laparoscopic cholecystectomy procedure. Results All patients except two were operated on successfully. Conversion was considered the placement of an additional epigastric/Right upper quadrant (RUQ) port. The conversion rate to standard LC was 7%. No patient was converted to open cholecystectomy. In the 28 successfully completed patients, the median duration of the operation was 38.5 min and estimated operative blood loss was 24 ml. Patients were commenced on liquid diet immediately on being fully conscious and after return to the ward with an estimated time of 6 h. The mean postoperative hospital stay was 1.4 days. Follow-up visits were conducted for all patients at 2-weeks intervals and continued for 6 weeks after surgery where possible. Two patients developed wound infections. All patients were satisfied with the good cosmetic effect of the surgery. The total satisfaction rate was 100%. Conclusions SILC is a safe and feasible technique for operating with scarless outcomes and reducing perioperative discomfort at the same time. The GelPOINTTM is a safe and feasible platform to be used. The procedure can be accomplished using regular instruments and laparoscope. Curved instruments and a bariatric length laparoscope may make the procedure easier and result in greater time saving. The addition of LigaSure™ decreases the complexity of the operation, decreases operative time and blood loss. The technique is economical in a resource-limited environment.
Collapse
|
12
|
Ahnen TV, Ahnen MV, Wirth U, Barisic A, Schardey HM, Schopf S. Comparison of an Intraoperative Application of a Haemostatic Agent (PerClot<sup>®</sup>) with Conventional Haemostatic Procedure after Thyroid Resection. ACTA ACUST UNITED AC 2015. [DOI: 10.4236/ss.2015.66037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
13
|
Butskiy O, Wiseman SM. Electrothermal bipolar vessel sealing system (LigaSure™) for hemostasis during thyroid surgery: a comprehensive review. Expert Rev Med Devices 2014; 10:389-410. [DOI: 10.1586/erd.13.6] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
14
|
Total thyroidectomy: Ligasure versus Clamp & Knot technique for intraoperative hemostasis. ACTA ACUST UNITED AC 2013. [DOI: 10.1016/j.ejenta.2013.02.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
15
|
Martin ST, Heeney A, Pierce C, O’Connell PR, Hyland JM, Winter DC. Use of an electrothermal bipolar sealing device in ligation of major mesenteric vessels during laparoscopic colorectal resection. Tech Coloproctol 2011; 15:285-9. [DOI: 10.1007/s10151-011-0707-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Accepted: 06/20/2011] [Indexed: 11/24/2022]
|
16
|
Smith CT, Zarebczan B, Alhefdhi A, Chen H. Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma. J Surg Res 2011; 170:64-8. [PMID: 21529840 DOI: 10.1016/j.jss.2011.03.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2011] [Revised: 02/07/2011] [Accepted: 03/02/2011] [Indexed: 11/13/2022]
Abstract
BACKGROUND During thyroid lobectomy, division of the thyroid parenchyma has traditionally been accomplished using suture ligation. Development of hemostatic techniques in the forms of ultrasonic dissection (UD) and electronic vessel sealing (EVS) have increased the usage of these devices during thyroid operations. We sought to characterize the thermal profile of each of these devices when used to divide the parenchyma of the thyroid gland. METHODS Using a porcine model, the parenchyma of the gland was sealed by alternating application of the UD and EVS devices. In each case, the thermal activity was recorded using infrared thermal imaging. We performed multiple seals with each instrument and then compared the thermal profiles. RESULTS There was no significant difference in lateral thermal spread of EVS and UD above 39, 40 or 60°C (2.30 ± 0.31 mm versus 2.53 ± 0.47 mm, P = 0.26; 2.22 ± 0.27 mm versus 2.47 ± 0.47 mm, P = 0.22, and 1.37 ± 0.27 mm versus 1.54 ± 0.26 mm, P = 0.22). There was no significant difference in mean time above 39 or 40°C (35.1 ± 8.7 s versus 31.7 ± 9.3 s, P = 0.47 and 29.9 ± 8.1 s versus 27.3 ± 6.7 s, P = 0.50). UD reached a greater maximum temperature (179.12 ± 0.0008C versus 96.52 ± 5.6C, P ≤ 0.001) and stayed over 60°C for longer than EVS (9.5 ± 1.8 s versus 5.3 ± 0.97 , P ≤ 0.001). CONCLUSIONS The amount of lateral spread of thermal energy was not significantly different between the UD and EVS devices. However, the use of UD produced a higher maximum temperature during thyroid parenchyma sealing and remained above 60°C longer than EVS. This may translate into greater thermal injury to thyroid and surrounding tissues during division.
Collapse
Affiliation(s)
- Carter T Smith
- Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin 53792, USA
| | | | | | | |
Collapse
|
17
|
Turial S, Engel V, Sultan T, Schier F. Closure of the Cystic Duct During Laparoscopic Cholecystectomy in Children Using the LigaSure Vessel Sealing System. World J Surg 2010; 35:212-6. [DOI: 10.1007/s00268-010-0813-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|