Nakajima K, Okuda K, Momose M, Matsuo S, Kondo C, Sarai M, Shibutani T, Onoguchi M, Shimizu T, Vija AH. IQ·SPECT technology and its clinical applications using multicenter normal databases. Ann Nucl Med 2017; 31:649-659. [PMID: 28940141 PMCID: PMC5651712 DOI: 10.1007/s12149-017-1210-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2017] [Accepted: 09/11/2017] [Indexed: 11/26/2022]
Abstract
IQ·SPECT (Siemens Medical Solutions) is a solution for high-sensitivity and short-time acquisition imaging of the heart for a variable angle general purpose gamma camera. It consists of a multi-focal collimator, a cardio-centric orbit and advanced iterative reconstruction, modeling the image formation physics accurately. The multi-focal collimator enables distance-dependent enlargement of the center region while avoiding truncation at the edges. With the specified configuration and a cardio-centric orbit it can obtain a fourfold sensitivity increase for the heart at the center of the scan orbit. Since IQ·SPECT shows characteristic distribution patterns in the myocardium, appropriate acquisition and processing conditions are required, and normal databases are convenient for quantification of both normal and abnormal perfusion images. The use of prone imaging can be a good option when X-ray computed tomography (CT) is not available for attenuation correction. CT-based attenuation correction changes count distribution significantly in the inferior wall and around the apex, hence image interpretation training and additional use of normal databases are recommended. Recent reports regarding its technology, Japanese Society of Nuclear Medicine working group activities, and clinical studies using 201Tl and 99mTc-perfusion tracers in Japan are summarized.
Collapse
Affiliation(s)
- Kenichi Nakajima
- Department of Nuclear Medicine, Kanazawa University, 13-1 Takara-machi, Kanazawa, 920-8641, Japan.
| | - Koichi Okuda
- Department of Physics, Kanazawa Medical University, Uchinada, Kahoku, Japan
| | - Mitsuru Momose
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Woman's Medical University, Tokyo, Japan
| | - Shinro Matsuo
- Department of Nuclear Medicine, Kanazawa University, 13-1 Takara-machi, Kanazawa, 920-8641, Japan
| | - Chisato Kondo
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Woman's Medical University, Tokyo, Japan
- Koishikawa Yanagimachi Clinic, Tokyo, Japan
| | - Masayoshi Sarai
- Department of Cardiology, Fujita Health University Hospital, Toyoake, Japan
| | - Takayuki Shibutani
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | - Masahisa Onoguchi
- Department of Quantum Medical Technology, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Japan
| | | | - A Hans Vija
- Siemens Medical Solution USA, Inc., Molecular Imaging, Hoffman Estates, IL, USA
| |
Collapse
|
2
|
Nakajima K, Scholte AJHA, Nakata T, Dimitriu-Leen AC, Chikamori T, Vitola JV, Yoshinaga K. Cardiac sympathetic nervous system imaging with 123I-meta-iodobenzylguanidine: Perspectives from Japan and Europe. J Nucl Cardiol 2017; 24:952-960. [PMID: 28290098 DOI: 10.1007/s12350-017-0818-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2017] [Accepted: 01/31/2017] [Indexed: 10/20/2022]
Abstract
Cardiac sympathetic nervous system dysfunction is closely associated with risk of serious cardiac events in patients with heart failure (HF), including HF progression, pump-failure death, and sudden cardiac death by lethal ventricular arrhythmia. For cardiac sympathetic nervous system imaging, 123I-meta-iodobenzylguanidine (123I-MIBG) was approved by the Japanese Ministry of Health, Labour and Welfare in 1992 and has therefore been widely used since in clinical settings. 123I-MIBG was also later approved by the Food and Drug Administration (FDA) in the United States of America (USA) and it was expected to achieve broad acceptance. In Europe, 123I-MIBG is currently used only for clinical research. This review article is based on a joint symposium of the Japanese Society of Nuclear Cardiology (JSNC) and the American Society of Nuclear Cardiology (ASNC), which was held in the annual meeting of JSNC in July 2016. JSNC members and a member of ASNC discussed the standardization of 123I-MIBG parameters, and clinical aspects of 123I-MIBG with a view to further promoting 123I-MIBG imaging in Asia, the USA, Europe, and the rest of the world.
Collapse
Affiliation(s)
- Kenichi Nakajima
- Department of Nuclear Medicine, Kanazawa University Hospital, Kanazawa, Japan
| | - Arthur J H A Scholte
- Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Tomoaki Nakata
- Department of Cardiology, Hakodate Goryokaku Hospital, Hakodate, Japan
| | | | | | | | - Keiichiro Yoshinaga
- Diagnostic and Therapeutic Nuclear Medicine, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-Ku, Chiba, 263-8555, Japan.
| |
Collapse
|