1
|
Maruyama S. Gaussian Function Model for Task-Specific Evaluation in Medical Imaging: A Theoretical Investigation. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2025:10.1007/s10278-025-01511-9. [PMID: 40274693 DOI: 10.1007/s10278-025-01511-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2025] [Revised: 04/02/2025] [Accepted: 04/15/2025] [Indexed: 04/26/2025]
Abstract
In medical image diagnosis, understanding image characteristics is crucial for selecting and optimizing imaging systems and advancing their development. Objective image quality assessments, based on specific diagnostic tasks, have become a standard in medical image analysis, bridging the gap between experimental observations and clinical applications. However, conventional task-based assessments often rely on ideal observer models that assume target signals have circular shapes with well-defined edges. This simplification rarely reflects the true complexity of lesion morphology, where edges exhibit variability. This study proposes a more practical approach by employing a Gaussian distribution to represent target signal shapes. This study explicitly derives the task function for Gaussian signals and evaluates the detectability index through simulations based on head computed tomography (CT) images with low-contrast lesions. Detectability indices were calculated for both circular and Gaussian signals using non-prewhitening and Hotelling observer models. The results demonstrate that Gaussian signals consistently exhibit lower detectability indices compared to circular signals, with differences becoming more pronounced for larger signal sizes. Simulated images closely resembling actual CT images confirm the validity of these calculations. These findings quantitatively clarify the influence of signal shape on detection performance, highlighting the limitations of conventional circular models. Thus, it provides a theoretical framework for task-based assessments in medical imaging, offering improved accuracy and clinical relevance for future advancements in the field.
Collapse
Affiliation(s)
- Sho Maruyama
- Department of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Gunma, Japan.
| |
Collapse
|
2
|
Chen Y, Pretorius PH, Yang Y, King MA, Lindsay C. Investigation of scatter energy window width and count levels for deep learning-based attenuation map estimation in cardiac SPECT/CT imaging. Phys Med Biol 2024; 69:10.1088/1361-6560/ad8b09. [PMID: 39447603 PMCID: PMC11636602 DOI: 10.1088/1361-6560/ad8b09] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2024] [Accepted: 10/23/2024] [Indexed: 10/26/2024]
Abstract
Objective.Deep learning (DL) is becoming increasingly important in generating attenuation maps for accurate attenuation correction (AC) in cardiac perfusion SPECT imaging. Typically, DL models take inputs from initial reconstructed SPECT images, which are performed on the photopeak window and often also on scatter windows. While prior studies have demonstrated improvements in DL performance when scatter window images are incorporated into the DL input, the comprehensive analysis of the impact of employing different scatter windows remains unassessed. Additionally, existing research mainly focuses on applying DL to SPECT scans obtained at clinical standard count levels. This study aimed to assess utilities of DL from two aspects: (1) investigating the impact when different scatter windows were used as input to DL, and (2) evaluating the performance of DL when applied on SPECT scans acquired at a reduced count level.Approach.We utilized 1517 subjects, with 386 subjects for testing and the remaining 1131 for training and validation.Main results.The results showed that as scatter window width increased from 4% to 30%, a slight improvement was observed in DL estimated attenuation maps. The application of DL models to quarter-count (¼-count) SPECT scans, compared to full-count scans, showed a slight reduction in performance. Nonetheless, discrepancies across different scatter window configurations and between count levels were minimal, with all normalized mean square error (NMSE) values remaining within 2.1% when comparing the different DL attenuation maps to the reference CT maps. For attenuation corrected SPECT slices using DL estimated maps, NMSE values were within 0.5% when compared to CT correction.Significance.This study, leveraging an extensive clinical dataset, showed that the performance of DL seemed to be consistent across the use of varied scatter window settings. Moreover, our investigation into reduced count studies indicated that DL could provide accurate AC even at a ¼-count level.
Collapse
Affiliation(s)
- Yuan Chen
- Department of Radiology, University of Massachusetts
Medical School, Worcester, MA, USA
| | - P. Hendrik Pretorius
- Department of Radiology, University of Massachusetts
Medical School, Worcester, MA, USA
| | - Yongyi Yang
- Department of Electrical and Computer Engineering, Illinois
Institute of Technology, Chicago, IL, USA
| | - Michael A. King
- Department of Radiology, University of Massachusetts
Medical School, Worcester, MA, USA
| | - Clifford Lindsay
- Department of Radiology, University of Massachusetts
Medical School, Worcester, MA, USA
| |
Collapse
|
3
|
Pretorius PH, Liu J, Kalluri KS, Jiang Y, Leppo JA, Dahlberg ST, Kikut J, Parker MW, Keating FK, Licho R, Auer B, Lindsay C, Konik A, Yang Y, Wernick MN, King MA. Observer studies of image quality of denoising reduced-count cardiac single photon emission computed tomography myocardial perfusion imaging by three-dimensional Gaussian post-reconstruction filtering and deep learning. J Nucl Cardiol 2023; 30:2427-2437. [PMID: 37221409 PMCID: PMC11401514 DOI: 10.1007/s12350-023-03295-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Accepted: 04/25/2023] [Indexed: 05/25/2023]
Abstract
BACKGROUND The aim of this research was to asses perfusion-defect detection-accuracy by human observers as a function of reduced-counts for 3D Gaussian post-reconstruction filtering vs deep learning (DL) denoising to determine if there was improved performance with DL. METHODS SPECT projection data of 156 normally interpreted patients were used for these studies. Half were altered to include hybrid perfusion defects with defect presence and location known. Ordered-subset expectation-maximization (OSEM) reconstruction was employed with the optional correction of attenuation (AC) and scatter (SC) in addition to distance-dependent resolution (RC). Count levels varied from full-counts (100%) to 6.25% of full-counts. The denoising strategies were previously optimized for defect detection using total perfusion deficit (TPD). Four medical physicist (PhD) and six physician (MD) observers rated the slices using a graphical user interface. Observer ratings were analyzed using the LABMRMC multi-reader, multi-case receiver-operating-characteristic (ROC) software to calculate and compare statistically the area-under-the-ROC-curves (AUCs). RESULTS For the same count-level no statistically significant increase in AUCs for DL over Gaussian denoising was determined when counts were reduced to either the 25% or 12.5% of full-counts. The average AUC for full-count OSEM with solely RC and Gaussian filtering was lower than for the strategies with AC and SC, except for a reduction to 6.25% of full-counts, thus verifying the utility of employing AC and SC with RC. CONCLUSION We did not find any indication that at the dose levels investigated and with the DL network employed, that DL denoising was superior in AUC to optimized 3D post-reconstruction Gaussian filtering.
Collapse
Affiliation(s)
- P Hendrik Pretorius
- Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, USA.
| | - Junchi Liu
- Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Kesava S Kalluri
- Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, USA
| | | | | | - Seth T Dahlberg
- Cardiovascular Medicine, University of Massachusetts Chan Medical School, Worcester, MA, USA
| | - Janusz Kikut
- University of Vermont Medical Center, Burlington, VT, USA
| | - Matthew W Parker
- Cardiovascular Medicine, University of Massachusetts Chan Medical School, Worcester, MA, USA
| | | | - Robert Licho
- UMass Memorial Medical Center - University Campus, Worcester, MA, USA
| | - Benjamin Auer
- Brigham and Women's Hospital Department of Radiology, Boston, MA, USA
| | - Clifford Lindsay
- Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, USA
| | - Arda Konik
- Dana-Farber Cancer Institute Department of Radiation Oncology, Boston, MA, USA
| | - Yongyi Yang
- Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Miles N Wernick
- Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | - Michael A King
- Division of Nuclear Medicine, Department of Radiology, University of Massachusetts Chan Medical School, Worcester, MA, USA
| |
Collapse
|
4
|
Garcia EV. Deep learning, another important tool for improving acquisition efficiency in SPECT MPI Imaging. J Nucl Cardiol 2021; 28:2780-2783. [PMID: 32419070 DOI: 10.1007/s12350-020-02188-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 05/04/2020] [Indexed: 12/18/2022]
Affiliation(s)
- Ernest V Garcia
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, 101 Woodruff Circle, Room 1203, Atlanta, GA, 30322, USA.
| |
Collapse
|
5
|
Krupinski EA. The important role of task-based model observers and related techniques in medical imaging. J Nucl Cardiol 2021; 28:638-640. [PMID: 31144227 DOI: 10.1007/s12350-019-01769-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Accepted: 05/21/2019] [Indexed: 11/24/2022]
Affiliation(s)
- Elizabeth A Krupinski
- Department of Radiology & Imaging Sciences Emory University, 1364 Clifton Rd NE, Atlanta, GA, 30322, USA.
| |
Collapse
|
6
|
Liu J, Yang Y, Wernick MN, Pretorius PH, King MA. Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging. Med Phys 2020; 48:156-168. [PMID: 33145782 DOI: 10.1002/mp.14577] [Citation(s) in RCA: 31] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2020] [Revised: 08/20/2020] [Accepted: 09/17/2020] [Indexed: 02/06/2023] Open
Abstract
PURPOSE Post-reconstruction filtering is often applied for noise suppression due to limited data counts in myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT). We study a deep learning (DL) approach for denoising in conventional SPECT-MPI acquisitions, and investigate whether it can be more effective for improving the detectability of perfusion defects compared to traditional postfiltering. METHODS Owing to the lack of ground truth in clinical studies, we adopt a noise-to-noise (N2N) training approach for denoising in SPECT-MPI images. We consider a coupled U-Net (CU-Net) structure which is designed to improve learning efficiency through feature map reuse. For network training we employ a bootstrap procedure to generate multiple noise realizations from list-mode clinical acquisitions. In the experiments we demonstrated the proposed approach on a set of 895 clinical studies, where the iterative OSEM algorithm with three-dimensional (3D) Gaussian postfiltering was used to reconstruct the images. We investigated the detection performance of perfusion defects in the reconstructed images using the non-prewhitening matched filter (NPWMF), evaluated the uniformity of left ventricular (LV) wall in terms of image intensity, and quantified the effect of smoothing on the spatial resolution of the reconstructed LV wall by using its full-width at half-maximum (FWHM). RESULTS Compared to OSEM with Gaussian postfiltering, the DL denoised images with CU-Net significantly improved the detection performance of perfusion defects at all contrast levels (65%, 50%, 35%, and 20%). The signal-to-noise ratio (SNRD ) in the NPWMF output was increased on average by 8% over optimal Gaussian smoothing (P < 10-4 , paired t-test), while the inter-subject variability was greatly reduced. The CU-Net also outperformed a 3D nonlocal means (NLM) filter and a convolutional autoencoder (CAE) denoising network in terms of SNRD . In addition, the FWHM of the LV wall in the reconstructed images was varied by less than 1%. Furthermore, CU-Net also improved the detection performance when the images were processed with less post-reconstruction smoothing (a trade-off of increased noise for better LV resolution), with SNRD improved on average by 23%. CONCLUSIONS The proposed DL with N2N training approach can yield additional noise suppression in SPECT-MPI images over conventional postfiltering. For perfusion defect detection, DL with CU-Net could outperform conventional 3D Gaussian filtering with optimal setting as well as NLM and CAE.
Collapse
Affiliation(s)
- Junchi Liu
- Medical Imaging Research Center and Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA
| | - Yongyi Yang
- Medical Imaging Research Center and Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA
| | - Miles N Wernick
- Medical Imaging Research Center and Department of Electrical and Computer Engineering, Illinois Institute of Technology, Chicago, IL, 60616, USA
| | - P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, Worcester, MA, 01655, USA
| | - Michael A King
- Department of Radiology, University of Massachusetts Medical School, Worcester, MA, 01655, USA
| |
Collapse
|