1
|
Madani-Nejad E, Shokrollahi A, Shahdost-Fard F. Central composite design-assisted visual and non-invasive detection of sertraline by sweet lemon waste-derived core-shell AuNPs@CDs. Anal Chim Acta 2024; 1312:342721. [PMID: 38834258 DOI: 10.1016/j.aca.2024.342721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/08/2024] [Accepted: 05/12/2024] [Indexed: 06/06/2024]
Abstract
This study reports a fast and visual detection method of antidepressant sertraline (SRT) drug by the core-shell AuNPs@CDs as the nanoprobes. The CDs has been eco-friendly synthesized from sweet lemon wastes to directly reduce Au+ to AuNPs without any external photoirradiation process or additional reductants. Optimizing key variables that impact the sensing process has been done using the central composite design (CCD) approach to simulate the assay condition before the analysis. Adding SRT with different concentrations to the nanoprobes under mildly acidic conditions presents an absorbance peak at 560 nm with purple color tonalities that differ from the behavior of alone nanoprobes (530 nm, pink color). The obtained absorption change is linearly proportional to the increase of SRT concentration from 1 μM to 35 μM with a limit of detection (LOD) value of 100 nM. The color changes with a vivid tonality from pink and purple to violet as the colorful fingerprint patterns are readily traceable by the naked eye, allowing the visual assay of SRT. The greenness of the developed approach is well evaluated by some international indexes including the complimentary green analytical procedure (ComplexGAPI) and also, the analytical greenness (AGREE) indexes. The proposed waste-derived nanoprobes based on the eco-friendly procedure not only conduct quantitative and qualitative non-invasive analysis of SRT by the naked eye but also, may widen for other applications in various fields.
Collapse
Affiliation(s)
| | | | - Faezeh Shahdost-Fard
- Department of Chemistry Education, Farhangian University, P.O. Box 14665-889, Tehran, Iran.
| |
Collapse
|
2
|
de Lima LF, Lopes Ferreira A, Martinez de Freitas ADS, de Souza Rodrigues J, Lemes AP, Ferreira M, de Araujo WR. Biodegradable and Flexible Thermoplastic Composite Graphite Electrodes: A Promising Platform for Inexpensive and Sensitive Electrochemical Detection of Creatine Kinase at the Point-of-Care. ACS APPLIED MATERIALS & INTERFACES 2023; 15:18694-18706. [PMID: 37014991 DOI: 10.1021/acsami.3c01379] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/19/2023]
Abstract
Acute myocardial infarction (AMI) is the main cause of death worldwide, and the time of diagnosis is decisive for the effectiveness of the treatment of patients with AMI. Creatine kinase-myocardial band (CK-MB) has a predominance and high affinity with myocardial tissue, making it considered one of the main biomarkers for the diagnosis of AMI. In this work, we report a novel biodegradable composite material based on a polymer blend of Poly(3-hydroxybutyrate-co-3-hydroxyvalerate) and Poly(butylene adipate-co-terephthalate) (PHBV:Ecoflex) and graphite microparticles for sensitive and selective electrochemical detection of CK-MB. The morphological and physicochemical characterizations of the thermoplastic composite material revealed a homogeneous and synergistic distribution of the graphite microparticles through the blend structure, providing low defects and high electrical conductivity with high electron transfer kinetics (k0 = 3.54 × 10-3 cm s-1) features with adequate flexibility for point-of-care applications. The portable and disposable devices were applied to detect CK-MB using the electrochemical impedance spectroscopy (EIS) technique in a relevant clinical concentration ranging from 5.0 ng mL-1 to 100.0 ng mL-1 and presented a limit of detection of 0.26 ng mL-1 CK-MB. The selectivity of the sensor was confirmed by testing the potential interference of major biomolecules found in biofluids and other relevant macromolecules. The accuracy and robustness were assessed by addition and recovery protocol in urine and saliva samples without sample pretreatment and demonstrated the potential of our method for rapid and decentralized tests of AMI. In addition, the study of the thermal, biological, and photodegradation of the devices after being used was also carried out, aiming at the disposal of the material more sustainably.
Collapse
Affiliation(s)
- Lucas Felipe de Lima
- Portable Chemical Sensors Lab, Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas (UNICAMP), 13083-970, Campinas, São Paulo, Brazil
| | - André Lopes Ferreira
- Portable Chemical Sensors Lab, Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas (UNICAMP), 13083-970, Campinas, São Paulo, Brazil
| | - Amanda de Sousa Martinez de Freitas
- Polymers and Biopolymers Technology Lab. (TecPBio), Institute of Science and Technology (ICT), Federal University of São Paulo (UNIFESP), 12231-280, São José dos Campos, São Paulo, Brazil
| | - Jéssica de Souza Rodrigues
- Center of Science and Technology for Sustainability (CCTS), Federal University of São Carlos (UFSCar), 18052-780, Sorocaba, São Paulo, Brazil
| | - Ana Paula Lemes
- Polymers and Biopolymers Technology Lab. (TecPBio), Institute of Science and Technology (ICT), Federal University of São Paulo (UNIFESP), 12231-280, São José dos Campos, São Paulo, Brazil
| | - Marystela Ferreira
- Center of Science and Technology for Sustainability (CCTS), Federal University of São Carlos (UFSCar), 18052-780, Sorocaba, São Paulo, Brazil
| | - William Reis de Araujo
- Portable Chemical Sensors Lab, Department of Analytical Chemistry, Institute of Chemistry, State University of Campinas (UNICAMP), 13083-970, Campinas, São Paulo, Brazil
| |
Collapse
|
3
|
Papavasileiou AV, Hoder T, Medek T, Prodromidis MI, Hrbac J. Sensitive riboflavin sensing using silver nanoparticles deposited onto screen-printed electrodes via controlled-energy spark discharges. Talanta 2023; 258:124409. [PMID: 36871518 DOI: 10.1016/j.talanta.2023.124409] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 02/27/2023] [Accepted: 03/01/2023] [Indexed: 03/05/2023]
Abstract
In this work, we elaborated the graphite screen-printed electrodes (SPEs) modification with metal nanoparticles formed as a result of spark discharges produced between a metal wire electrode and SPE that are connected to an Arduino board-based DC high voltage power supply. This sparking device allows, on the one hand, the toposelective formation of NPs of controlled dimensions through a direct and liquid-free approach, and on the other hand, controls the number and energy of the discharges delivered to the electrode surface during a single spark event. This way, the potential damage to the SPE surface by the action of heat evolved during the sparking process is considerably minimized compared with the standard setup in which each spark event consists of multiple electrical discharges. Data demonstrated that the sensing properties of the resulting electrodes are significantly improved compared with those achieved when conventional spark generators are employed, as demonstrated for silver-sparked SPEs that exhibit enhanced sensitivity to riboflavin. Sparked AgNp-SPEs were characterized using scanning electron microscopy and voltammetric measurements in alkaline conditions. The analytical performance of sparked AgNP-SPEs was evaluated by various electrochemical techniques. Under optimum conditions, the detection range for DPV was from 1.9 (LOQ) to 100 nM riboflavin (R2 = 0.997), while a limit of detection (LOD, S/N 3) of 0.56 nM was achieved. The analytical utility is demonstrated for the determination of riboflavin in the real matrices of B-complex pharmaceutical preparation and an energy drink.
Collapse
Affiliation(s)
- Anastasios V Papavasileiou
- Department of Chemistry, University of Ioannina, Ioannina 451 10, Greece; Institute of Chemistry, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Tomas Hoder
- Department of Physical Electronics, Masaryk University, Kotlarska 2, 611 37 Brno, Czech Republic
| | - Tomas Medek
- Department of Physical Electronics, Masaryk University, Kotlarska 2, 611 37 Brno, Czech Republic
| | | | - Jan Hrbac
- Institute of Chemistry, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
| |
Collapse
|
4
|
Comparative In Vitro Cytotoxicity Study of Carbon Dot-Based Organometallic Nanoconjugates: Exploration of Their Cell Proliferation, Uptake, and Localization in Cancerous and Normal Cells. OXIDATIVE MEDICINE AND CELLULAR LONGEVITY 2022; 2022:3483073. [PMID: 35340219 PMCID: PMC8941570 DOI: 10.1155/2022/3483073] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 02/03/2022] [Accepted: 02/10/2022] [Indexed: 11/18/2022]
Abstract
Organometallic nanoconjugates have raised great interest due to their bimodal properties and high stability. In the present study, we analyzed the cytotoxicity property of carbon dots (CDs) and a series of organometallic nanoconjugates including gold@carbon dots (Au@CDs) and silver@carbon dots (Ag@CDs) synthesized via an aqueous mode. We aimed to divulge a comparative analysis of cell proliferation, uptake, and localization of the particles in HeLa and HEK293 cell lines. Our results showed dose-dependent cytotoxicity of Au@CDs, Ag@CDs, and CDs. However, Ag@CDs showed the highest inhibition through HeLa cells with an IC50 value of around 50 ± 1.0 μg/mL. Confocal imaging signified the uptake of the particles suggested by blue fluorescence in the interior region of HeLa cells. Furthermore, the TEM micrographs depicted that the particles are entrapped by endocytosis assisted through the cell microvilli. The CDs and Au@CDs were thus observed to be relatively safe up to a concentration of 100 μg/mL and did not induce any morphological changes in the cells. Moreover, the cell proliferation assay of these nanoconjugates against HEK 293 cells signified the nontoxic nature of the nanoconjugates. The results thus revealed two major facts: firstly, the Ag@CDs had potent therapeutic potential, signifying their potential as a promising anticancer drug, and secondly, the CDs and Au@CDs at a defined dose could be used as probes for detection and also bioimaging agents.
Collapse
|
5
|
Recent analytical methodologies and analytical trends for riboflavin (vitamin B2) analysis in food, biological and pharmaceutical samples. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116412] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Hussain A, Rafeeq H, Qasim M, Jabeen Z, Bilal M, Franco M, Iqbal HMN. Engineered tyrosinases with broadened bio-catalysis scope: immobilization using nanocarriers and applications. 3 Biotech 2021; 11:365. [PMID: 34290948 PMCID: PMC8257883 DOI: 10.1007/s13205-021-02913-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2021] [Accepted: 06/28/2021] [Indexed: 02/08/2023] Open
Abstract
Enzyme immobilization is a widely used technology for creating more stable, active, and reusable biocatalysts. The immobilization process also improves the enzyme's operating efficiency in industrial applications. Various support matrices have been designed and developed to enhance the biocatalytic efficiency of immobilized enzymes. Given their unique physicochemical attributes, including substantial surface area, rigidity, semi-conductivity, high enzyme loading, hyper catalytic activity, and size-assisted optical properties, nanomaterials have emerged as fascinating matrices for enzyme immobilization. Tyrosinase is a copper-containing monooxygenase that catalyzes the o-hydroxylation of monophenols to catechols and o-quinones. This enzyme possesses a wide range of uses in the medical, biotechnological, and food sectors. This article summarizes an array of nanostructured materials as carrier matrices for tyrosinase immobilization. Following a detailed background overview, various nanomaterials, as immobilization support matrices, including carbon nanotubes (CNTs), carbon dots (CDs), carbon black (CB), nanofibers, Graphene nanocomposite, platinum nanoparticles, nano-sized magnetic particles, lignin nanoparticles, layered double hydroxide (LDH) nanomaterials, gold nanoparticles (AuNPs), and zinc oxide nanoparticles have been discussed. Next, applied perspectives have been spotlights with particular reference to environmental pollutant sensing, phenolic compounds detection, pharmaceutical, and food industry (e.g., cereal processing, dairy processing, and meat processing), along with other miscellaneous applications.
Collapse
Affiliation(s)
- Asim Hussain
- Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Hamza Rafeeq
- Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Muhammad Qasim
- International Islamic University Islamabad, Islamabad, Pakistan
| | - Zara Jabeen
- Department of Biochemistry, Riphah International University, Faisalabad, Pakistan
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huai’an, 223003 China
| | - Marcelo Franco
- Departament of Exact Sciences and Technology, State University of Santa Cruz, Ilhéus, Brazil
| | - Hafiz M. N. Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, 64849 Monterrey, Mexico
| |
Collapse
|
7
|
Wang Z, Zhang L, Hao Y, Dong W, Liu Y, Song S, Shuang S, Dong C, Gong X. Ratiometric fluorescent sensors for sequential on-off-on determination of riboflavin, Ag + and l-cysteine based on NPCl-doped carbon quantum dots. Anal Chim Acta 2021; 1144:1-13. [PMID: 33453785 DOI: 10.1016/j.aca.2020.11.054] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/25/2020] [Accepted: 11/30/2020] [Indexed: 01/25/2023]
Abstract
The fluorescent sensor, especially ratiometric fluorescent sensor, is one of the most important applications for CQDs, which is becoming a research hotspot. Herein, carbon quantum dots co-doped with nitrogen, phosphorus and chlorine (NPCl-CQDs) were synthesized by acid-base neutralization reaction exothermic carbonization method. The as-fabricated NPCl-CQDs could emit blue fluorescence and possess excellent fluorescence properties. Based on the FRET, multifunctional and ratiometric fluorescent sensors for "on-off-on" sequential determination of riboflavin, Ag+, and Cys with good selectivity and high sensitivity were established. The linear range of riboflavin, Ag+, and Cys are 0.50-10.18 μM and 15.89-27.76 μM, 0.66-1.46 mM and 1.50-4.20 mM, and 0.01-0.15 μM and 0.15-0.36 μM with the limit of detection of 3.50 nM, 26.38 μM, and 0.96 nM, respectively. Furthermore, the sensors were successfully used to determine riboflavin, Ag+, and Cys in tablets, river water, and human urine with the recoveries of 95.2-104.0%, 95.6-102.0%, and 94.8-106.4%, respectively. More importantly, the as-constructed "on-off-on" NPCl-CQDs-based ratiometric fluorescent sensors were applied for detecting riboflavin, Ag+, and Cys in HeLa cells with satisfying results. The finding of this study shows the feasibility and effectiveness of the NPCl-CQDs as the available ratiometric fluorescent sensors for the determination of riboflavin, Ag+, and Cys in real samples and living cells.
Collapse
Affiliation(s)
- Zihan Wang
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Li Zhang
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Yumin Hao
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Wenjuan Dong
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Yang Liu
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Shengmei Song
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Shaomin Shuang
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China
| | - Chuan Dong
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China.
| | - Xiaojuan Gong
- Institute of Environmental Science, And School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan, 030006, PR China.
| |
Collapse
|
8
|
Papavasileiou AV, Panagiotopoulos I, Prodromidis MI. All-screen-printed graphite sensors integrating permanent bonded magnets. Fabrication, characterization and analytical utility. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136981] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
9
|
Baluta S, Lesiak A, Cabaj J. Simple and Cost-Effective Electrochemical Method for Norepinephrine Determination Based on Carbon Dots and Tyrosinase. SENSORS 2020; 20:s20164567. [PMID: 32823962 PMCID: PMC7472078 DOI: 10.3390/s20164567] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Revised: 08/10/2020] [Accepted: 08/10/2020] [Indexed: 12/27/2022]
Abstract
Although neurotransmitters are present in human serum at the nM level, any dysfunction of the catecholamines concentration may lead to numerous serious health problems. Due to this fact, rapid and sensitive catecholamines detection is extremely important in modern medicine. However, there is no device that would measure the concentration of these compounds in body fluids. The main goal of the present study is to design a simple as possible, cost-effective new biosensor-based system for the detection of neurotransmitters, using nontoxic reagents. The miniature Au-E biosensor was designed and constructed through the immobilization of tyrosinase on an electroactive layer of cysteamine and carbon nanoparticles covering the gold electrode. This sensing arrangement utilized the catalytic oxidation of norepinephrine (NE) to NE quinone, measured with voltammetric techniques: cyclic voltammetry and differential pulse voltammetry. The prepared bio-system exhibited good parameters: a broad linear range (1–200 μM), limit of detection equal to 196 nM, limit of quantification equal to 312 nM, and high selectivity and sensitivity. It is noteworthy that described method was successfully applied for NE determination in real samples.
Collapse
Affiliation(s)
- Sylwia Baluta
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland; (S.B.); (A.L.)
| | - Anna Lesiak
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland; (S.B.); (A.L.)
- Faculty of Fundamental Problems of Technology, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland
| | - Joanna Cabaj
- Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland; (S.B.); (A.L.)
- Correspondence: ; Tel.: +48-71-320-4641
| |
Collapse
|