1
|
Kostorz-Nosal S, Jastrzębski D, Błach A, Skoczyński S. Window of opportunity for respiratory oscillometry: A review of recent research. Respir Physiol Neurobiol 2023; 316:104135. [PMID: 37536553 DOI: 10.1016/j.resp.2023.104135] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/19/2023] [Accepted: 07/30/2023] [Indexed: 08/05/2023]
Abstract
Oscillometry has been around for almost 70 years, but there are still many unknowns. The test is performed during tidal breathing and is therefore free from patient-dependent factors that could influence the results. The Forced Oscillation Technique (FOT), which requires minimal patient cooperation, is gaining ground, particularly with elderly patients and children. In pulmonology, it is a valuable tool for assessing obstructive conditions (with a distinction between central and peripheral obstruction) and restrictive disorders (intrapulmonary and extrapulmonary). Its sensitivity allows the assessment of bronchodilator and bronchoconstrictor responses. Different lung diseases show different patterns of changes in FOT, especially studied in asthma and chronic obstructive pulmonary disease. Because of these differences, many studies have analysed the usefulness of this technique in different areas of medicine. In this paper, the authors would like to present the basics of oscillometry with the areas of its most recent clinical applications.
Collapse
Affiliation(s)
- Sabina Kostorz-Nosal
- Department of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-803 Zabrze, Poland.
| | - Dariusz Jastrzębski
- Department of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-803 Zabrze, Poland
| | - Anna Błach
- Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland
| | - Szymon Skoczyński
- Department of Lung Diseases and Tuberculosis, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, 41-803 Zabrze, Poland
| |
Collapse
|
2
|
Abstract
Lung function testing is an essential modality of investigation in children as it provides objective evidence of lung disease/health. With advances in technology, various tests are available that can aid in the diagnosis of lung disease, assess the progression and response to therapy and document the lung development and evolving lung diseases in infants. This narrative review discusses lung function tests in infants and children. Currently, lung function tests can be performed in every age group, from neonates to the elderly. Spirometry and peak expiratory flow rate (PEFR) are the most employed tests in children more than six years of age. Spirometry helps diagnose and monitoring of both obstructive and restrictive diseases. There is a need for expertise to perform and interpret spirometry correctly. The forced oscillation technique (FOT) or impulse oscillometry (IOS) is done with tidal volume breathing and is feasible even in preschool children. Their utility is mainly restricted to asthma in children at present. Lung function tests can be performed in neonates, infants and children using infant pulmonary function test (PFT) equipment, although their availability is limited. Diffusion capacity for carbon monoxide (DLCO) is a valuable tool in restrictive lung diseases. Lung volumes can be assessed by body plethysmography and multiple washout technique. The latter can also assess lung clearance index. It is essential to perform and interpret the lung function test results correctly and correlate them with the clinical condition for optimum treatment and outcome.
Collapse
Affiliation(s)
- Kana Ram Jat
- Department of Pediatrics, All India Institute of Medical Sciences, New Delhi, 110029, India.
| | - Sheetal Agarwal
- Department of Pediatrics, All India Institute of Medical Sciences, New Delhi, 110029, India
- Department of Pediatrics, ABVIMS and Dr. RML Hospital, New Delhi, India
| |
Collapse
|
3
|
Lung Function Tests, Quality of Life and Telemedicine: Three Windows on the Multifaceted World of Asthma in Adolescents. CHILDREN 2022; 9:children9040476. [PMID: 35455520 PMCID: PMC9026868 DOI: 10.3390/children9040476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/15/2022] [Accepted: 03/28/2022] [Indexed: 11/17/2022]
Abstract
Asthma is a heterogeneous disease usually characterized by chronic airway inflammation and recognized as the most prevalent chronic illness among children. Despite this, the knowledge as to how asthma affects adolescents is still scarce. One of the main management problems of asthmatic adolescents is the poor adherence to pharmacological and non-pharmacological treatments. The assessment of respiratory function and the impact on quality of life are still two crucial challenges in the management of asthmatic adolescents. Additionally, the COVID-19 pandemic has prompted physicians to explore complementary management strategies including telemedicine technologies. This review aims to provide an update on the contribution of respiratory functional tests, how asthma affects quality of life of adolescents and, finally, how telemedicine contributes to the management of adolescent asthmatics during the COVID-19 pandemic.
Collapse
|
4
|
Evaluation of Impulse Oscillometry in Respiratory Airway Casts with Varying Obstruction Phenotypes, Locations, and Complexities. JOURNAL OF RESPIRATION 2022. [DOI: 10.3390/jor2010004] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
The use of impulse oscillometry (IOS) for lung function testing does not need patient cooperation and has gained increasing popularity among both young and senior populations, as well as in patients with breathing difficulties. However, studies of the IOS sensitivity to regional lung obstructions are limited and have shown mixed results. The objective of this study was to evaluate the performance of an IOS system in 3D-printed lung models with structural abnormalities at different locations and with different severities. Lung trees of two complexity levels were tested, with one extending to the sixth generation (G6) and the other to G12. The IOS responses to varying glottal apertures, carina ridge tumors, and segmental bronchial constrictions were quantified in the G6 lung geometry. Both the G6 and G12 lung casts were prepared using high-resolution 3D printers. Overall, IOS detected the progressive airway obstructions considered in this study. The resonant frequency dropped with increasing obstructions for all three disease phenotypes in the G6 lung models. R20Hz increased with the increase in airway obstructions. Specifically, R20Hz in the airway model with varying glottal apertures agreed reasonably well with complementary measurements using TSI VelociCalc. In contrast to the high-resistance (R) sensitivity to the frequency in G6 lung models, R was nearly independent of frequency in G12 lung models. IOS R20Hz demonstrated adequate sensitivity to the structural remodeling in the central airways. However, the changes of R5Hz and X5Hz vs. airway obstructions were inconclusive in this study, possibly due to the rigid lung casts and the difference of a container–syringe system from human lungs.
Collapse
|
5
|
Ling Y, Si M, Niu Y, Han Y, Xu Y. The predictive value of impulse oscillometry for asthma exacerbations in childhood: A systematic review and meta-analyses. Pediatr Pulmonol 2021; 56:1850-1856. [PMID: 33756052 PMCID: PMC8251639 DOI: 10.1002/ppul.25374] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 02/08/2021] [Accepted: 03/01/2021] [Indexed: 12/12/2022]
Abstract
OBJECTIVE Several studies have explored the predictive value of impulse oscillometry (IOS) for asthma exacerbations in childhood, but its specific parameters are still unclear. Therefore, we designed this meta-analysis to determine the related indicators of acute asthma attacks. METHODS A comprehensive literature search was performed on July 9, 2020 based on PubMed, Embase, and Web of Science database. Weighted mean differences (WMDs) were calculated using fixed- or random-effects models. RESULTS A total of 615 patients from six trials were included in this analysis. IOS may be a useful tool to predict asthma exacerbations. And the results showed that R5 (WMD = -1.21, 95% CI: -1.55 to -0.87, p < .001), Fres (WMD = -1.34, 95% CI: -2.03 to -0.65, p = .018), and AX (WMD = -7.35, 95% CI: -9.94 to -4.76, p < .001) had significant correlation with asthma exacerbations. In addition, X5 may also predict the acute attack of asthma (WMD = 0.81, 95% CI: 0.56 to 1.01, p < .001). CONCLUSIONS R5, AX, Fres, and X5 may be able to identify the risk of an acute attack of asthma. Besides, our research further demonstrated that peripheral airway injury may play an important role in the acute attack of asthma.
Collapse
Affiliation(s)
- Yaoyao Ling
- Graduate School of Tianjin Medical University, Tianjin, China
| | - Minghui Si
- Graduate School of Tianjin Medical University, Tianjin, China
| | - Yufan Niu
- Graduate School of Tianjin Medical University, Tianjin, China
| | - Yuqi Han
- Graduate School of Tianjin Medical University, Tianjin, China
| | - Yongsheng Xu
- Department of Respiratory, The Children's Hospital of Tianjin (Children's Hospital of Tianjin University), Tianjin, China
| |
Collapse
|
6
|
Chaiwong W, Namwongprom S, Liwsrisakun C, Pothirat C. The roles of impulse oscillometry in detection of poorly controlled asthma in adults with normal spirometry. J Asthma 2021; 59:561-571. [PMID: 33356696 DOI: 10.1080/02770903.2020.1868499] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
BACKGROUND Impulse oscillometry (IOS) has been introduced as a method of assessing asthma control. However, the cutoff IOS values for the detection of asthma control in adults are still unclear. OBJECTIVE To assess the diagnostic ability of IOS for distinguishing between poorly controlled and well controlled adult asthmatic subjects with normal spirometry. METHODS This cross-sectional study was conducted at the Lung Health Center, Chiang Mai, Thailand, between July 2019 and June 2020. IOS and spirometry were performed in all adult asthmatic subjects but only subjects with normal spirometry were enrolled. Poorly controlled asthma was defined in accordance with the Global Initiative for Asthma (GINA) plus an asthma control test (ACT) score ≤19. A Receiver Operating Characteristic (ROC) curve was plotted to detect poorly controlled asthma using the area under the ROC (AuROC) and 95%CI. RESULTS One hundred and forty-two adult asthmatic subjects registering normal spirometry with a mean age of 53.4 ± 15.8 years were enrolled. Eighty-nine (62.7%) subjects were female. IOS parameters including heterogeneity of resistance at 5 Hz and resistance at 20 Hz (R5-R20) and area under reactance (AX) demonstrated excellent detection of poorly controlled asthma with an AuROC of 0.911 and 0.904, respectively. The z-score or absolute value of R5-R20 ≥ 0 and 1 cmH2O/L/s, respectively, represented the highest AuROC of 0.86, with a sensitivity and a specificity of ≥80.0% for the detection of poorly controlled asthma. CONCLUSION IOS is a valuable tool for the detection of poorly controlled asthma in adults with normal spirometry.
Collapse
Affiliation(s)
- Warawut Chaiwong
- Division of Pulmonary, Critical Care, and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Clinical Epidemiology and Clinical Statistics Center, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Sirianong Namwongprom
- Clinical Epidemiology and Clinical Statistics Center, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.,Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Chalerm Liwsrisakun
- Division of Pulmonary, Critical Care, and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| | - Chaicharn Pothirat
- Division of Pulmonary, Critical Care, and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
7
|
Postek M, Walicka-Serzysko K, Milczewska J, Sands D. What Is Most Suitable for Children With Cystic Fibrosis-The Relationship Between Spirometry, Oscillometry, and Multiple Breath Nitrogen Washout. Front Pediatr 2021; 9:692949. [PMID: 35096700 PMCID: PMC8795905 DOI: 10.3389/fped.2021.692949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 11/29/2021] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION In cystic fibrosis (CF), pathological lung changes begin early in life. The technological progress currently gives many diagnostic possibilities. However, pulmonary function testing in children remains problematic. OBJECTIVES Our study aimed to correlate the results of impulse oscillometry (IOS) with those of multiple breath nitrogen washout (MBNW) in our pediatric CF population. We also compared those parameters between the groups with and without spirometric features of obturation. METHODS We collected 150 pulmonary function test sets, including spirometry, IOS, and MBNW in patients with CF aged 12.08 ± 3.85 years [6-18]. The study group was divided into two subgroups: IA (without obturation) and IB (with obturation). We also compared Sacin, Scond, and oscillometry parameters of 20 patients aged 14-18 years who reached the appropriate tidal volume (VT) during MBNW. RESULTS Statistical analysis showed a negative correlation between lung clearance index (LCI) and spimoetric parameters. Comparison of subgroups IA (n = 102) and IB (n = 48) indicated a statistically significant difference in LCI (p < 0.001) and FEV1z-score (p < 0.001), FEV1% pred (p < 0.001), MEF25z-score (p < 0.001), MEF50 z-score (p < 0.001), MEF75 z-score (p < 0.001), R5% pred (p < 0.05), and R20% pred (p < 0.01). LCI higher than 7.91 was found in 75.33% of the study group, in subgroup IB-91.67%, and IA-67.6%. CONCLUSIONS LCI derived from MBNW may be a better tool than IOS for assessing pulmonary function in patients with CF, particularly those who cannot perform spirometry.
Collapse
Affiliation(s)
- Magdalena Postek
- Cystic Fibrosis Department, Institute of Mother and Child, Warsaw, Poland.,Cystic Fibrosis Centre, Pediatric Hospital, Dziekanów Leśny, Poland
| | - Katarzyna Walicka-Serzysko
- Cystic Fibrosis Department, Institute of Mother and Child, Warsaw, Poland.,Cystic Fibrosis Centre, Pediatric Hospital, Dziekanów Leśny, Poland
| | - Justyna Milczewska
- Cystic Fibrosis Department, Institute of Mother and Child, Warsaw, Poland.,Cystic Fibrosis Centre, Pediatric Hospital, Dziekanów Leśny, Poland
| | - Dorota Sands
- Cystic Fibrosis Department, Institute of Mother and Child, Warsaw, Poland.,Cystic Fibrosis Centre, Pediatric Hospital, Dziekanów Leśny, Poland
| |
Collapse
|
8
|
Yadav CP, Lodha R, Kabra SK, Sreenivas V, Sinha A, Khan MA, Pandey RM. Comparison of statistical methods for recurrent event analysis using pediatrics asthma data. Pharm Stat 2020; 19:803-813. [PMID: 32484295 DOI: 10.1002/pst.2032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 04/30/2020] [Accepted: 05/06/2020] [Indexed: 11/10/2022]
Abstract
When the same type of event is experienced by a subject more than once it is called recurrent event, which possess two important characteristics, namely "within-subject correlation" and "time-varying covariate." As a result, the traditional statistical methods do not work well on recurrent event data. Over the past few decades, many alternatives methods have been proposed for the analysis of recurrent event data. In this article, the six most prominent methods for recurrent event analysis have been compared on pediatric asthma data. Three variance corrected models (viz "Anderson and Gill [AG] model," "Prentice, William, and Peterson-Counting Process [PWP-CP] model," and "Prentice, William, and Peterson-Gap Time [PWP-GT] model") and three corresponding frailty variants (AG-frailty, PWP-CP-frailty, and PWP-GT-frailty) were compared using three mathematical criterion (AIC, BIC, and log-likelihood) and one graphical criteria (Cox-Snell goodness of fit, visual test). All model comparison indices showed the PWP-GT model as the most appropriate model on asthma data over other models. By using PWP-GT model, seven predictors of asthma exacerbation (viz "abdominal pain at previous visit," "Z5 (%) at previous visit," "diagnosis of asthma at previous visit," "calendar month of exacerbation," "history of maternal asthma," "monthly per capita income," and "emotional stress") were identified. The PWP-GT model was identified as the most appropriate model over other models on pediatrics asthma data.
Collapse
Affiliation(s)
- C P Yadav
- ICMR-National Institute of Malaria Research (NIMR), New Delhi, India.,Department of Biostatistics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Rakesh Lodha
- Department of Pediatrics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - S K Kabra
- Department of Pediatrics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - V Sreenivas
- Department of Biostatistics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - Abhinav Sinha
- ICMR-National Institute of Malaria Research (NIMR), New Delhi, India
| | - M A Khan
- Department of Biostatistics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| | - R M Pandey
- Department of Biostatistics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
| |
Collapse
|
9
|
Bednarek M, Grabicki M, Piorunek T, Batura-Gabryel H. "Current place of impulse oscillometry in the assessment of pulmonary diseases.". Respir Med 2020; 170:105952. [PMID: 32843158 DOI: 10.1016/j.rmed.2020.105952] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Revised: 03/30/2020] [Accepted: 03/31/2020] [Indexed: 12/01/2022]
Abstract
In 1956, a diagnostic tool using the forced oscillation technique (FOT) was developed to examine respiratory functions. A modification of this method is impulse oscillometry (IOS). In the latter, a loudspeaker delivers to the respiratory system a regular, square pressure wave at a constant frequency from which all other individual frequencies are derived using spectral analysis. The usefulness of IOS has been examined in relation to COPD, asthma, interstitial lung diseases, obstructive sleep apnea, and other conditions. The greatest advantage, most notable in children, is the ability to monitor the course of a disease and to assess the response to therapy in a simple way, i.e., minimal requirements for the cooperation of the patient, rapid and reproducible measurements. The IOS shows similar or even higher sensitivity than spirometry in detecting small airways dysfunction (SAD). The most well-known result observed in peripheral airways disease (PAD) is the frequency dependence of resistance. Importantly, the abnormal resistance at a specific frequency may occur with normal spirometry in those with early PAD. Moreover, IOS is particularly useful if the patient cannot perform effort dependent exhalation. Despite its advantages, the technique is still poorly found in official worldwide recommendations. Nonetheless, considering the promising results of many studies, an increase in interest in IOS is expected, and it could soon be on par with standard pulmonary function tests. The aim of this work is to present the basics, current views, and various aspects of IOS. To carry out our analysis, we searched for relevant publications on PubMed, Web of Science. Original and review articles were selected and discussed.
Collapse
Affiliation(s)
- Marcin Bednarek
- Poznan University of Medical Sciences, Department of Pulmonology, Allergology and Respiratory Oncology, ul. Szamarzewskiego 84, 60-569, Wielkopolska, Poznan, Poland.
| | - Marcin Grabicki
- Poznan University of Medical Sciences, Department of Pulmonology, Allergology and Respiratory Oncology, ul. Szamarzewskiego 84, 60-569, Wielkopolska, Poznan, Poland
| | - Tomasz Piorunek
- Poznan University of Medical Sciences, Department of Pulmonology, Allergology and Respiratory Oncology, ul. Szamarzewskiego 84, 60-569, Wielkopolska, Poznan, Poland
| | - Halina Batura-Gabryel
- Poznan University of Medical Sciences, Department of Pulmonology, Allergology and Respiratory Oncology, ul. Szamarzewskiego 84, 60-569, Wielkopolska, Poznan, Poland
| |
Collapse
|
10
|
Can Impulse Oscillometry be Used to Monitor Asthmatic Children? Indian Pediatr 2020. [DOI: 10.1007/s13312-020-1723-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|