1
|
Will A, Oliinyk D, Bleiholder C, Meier F. Peptide collision cross sections of 22 post-translational modifications. Anal Bioanal Chem 2023; 415:6633-6645. [PMID: 37758903 PMCID: PMC10598134 DOI: 10.1007/s00216-023-04957-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 07/13/2023] [Accepted: 08/23/2023] [Indexed: 09/29/2023]
Abstract
Recent advances have rekindled the interest in ion mobility as an additional dimension of separation in mass spectrometry (MS)-based proteomics. Ion mobility separates ions according to their size and shape in the gas phase. Here, we set out to investigate the effect of 22 different post-translational modifications (PTMs) on the collision cross section (CCS) of peptides. In total, we analyzed ~4300 pairs of matching modified and unmodified peptide ion species by trapped ion mobility spectrometry (TIMS). Linear alignment based on spike-in reference peptides resulted in highly reproducible CCS values with a median coefficient of variation of 0.26%. On a global level, we observed a redistribution in the m/z vs. ion mobility space for modified peptides upon changes in their charge state. Pairwise comparison between modified and unmodified peptides of the same charge state revealed median shifts in CCS between -1.4% (arginine citrullination) and +4.5% (O-GlcNAcylation). In general, increasing modified peptide masses were correlated with higher CCS values, in particular within homologous PTM series. However, investigating the ion populations in more detail, we found that the change in CCS can vary substantially for a given PTM and is partially correlated with the gas phase structure of its unmodified counterpart. In conclusion, our study shows PTM- and sequence-specific effects on the cross section of peptides, which could be further leveraged for proteome-wide PTM analysis.
Collapse
Affiliation(s)
- Andreas Will
- Functional Proteomics, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany
| | - Denys Oliinyk
- Functional Proteomics, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany
| | - Christian Bleiholder
- Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, 32304, USA
| | - Florian Meier
- Functional Proteomics, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany.
| |
Collapse
|
2
|
Ma X. Recent Advances in Mass Spectrometry-Based Structural Elucidation Techniques. Molecules 2022; 27:6466. [PMID: 36235003 PMCID: PMC9572214 DOI: 10.3390/molecules27196466] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 09/23/2022] [Accepted: 09/26/2022] [Indexed: 11/17/2022] Open
Abstract
Mass spectrometry (MS) has become the central technique that is extensively used for the analysis of molecular structures of unknown compounds in the gas phase. It manipulates the molecules by converting them into ions using various ionization sources. With high-resolution MS, accurate molecular weights (MW) of the intact molecular ions can be measured so that they can be assigned a molecular formula with high confidence. Furthermore, the application of tandem MS has enabled detailed structural characterization by breaking the intact molecular ions and protonated or deprotonated molecules into key fragment ions. This approach is not only used for the structural elucidation of small molecules (MW < 2000 Da), but also crucial biopolymers such as proteins and polypeptides; therefore, MS has been extensively used in multiomics studies for revealing the structures and functions of important biomolecules and their interactions with each other. The high sensitivity of MS has enabled the analysis of low-level analytes in complex matrices. It is also a versatile technique that can be coupled with separation techniques, including chromatography and ion mobility, and many other analytical instruments such as NMR. In this review, we aim to focus on the technical advances of MS-based structural elucidation methods over the past five years, and provide an overview of their applications in complex mixture analysis. We hope this review can be of interest for a wide range of audiences who may not have extensive experience in MS-based techniques.
Collapse
Affiliation(s)
- Xin Ma
- School of Chemistry and Biochemistry, Georgia Institute of Technology, 901 Atlantic Dr NW, Atlanta, GA 30332, USA
| |
Collapse
|
3
|
Wang JY, Yin YH, Zheng JY, Liu LF, Yao ZP, Xin GZ. Least absolute shrinkage and selection operator-based prediction of collision cross section values for ion mobility mass spectrometric analysis of lipids. Analyst 2022; 147:1236-1244. [DOI: 10.1039/d1an02161c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A least absolute shrinkage and selection operator (LASSO)-based prediction method was developed for the prediction of lipids’ CCS values.
Collapse
Affiliation(s)
- Jian-Ying Wang
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, School of Traditional Chinese Pharmacy, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
- State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of Hong Kong Polytechnic University, Shenzhen 518057, China
- State Key Laboratory of Chemical Biology and Drug Discovery, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR, China
| | - Ying-Hao Yin
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, School of Traditional Chinese Pharmacy, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
| | - Jia-Yi Zheng
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, School of Traditional Chinese Pharmacy, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
| | - Li-Fang Liu
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, School of Traditional Chinese Pharmacy, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
| | - Zhong-Ping Yao
- State Key Laboratory of Chinese Medicine and Molecular Pharmacology (Incubation) and Shenzhen Key Laboratory of Food Biological Safety Control, Shenzhen Research Institute of Hong Kong Polytechnic University, Shenzhen 518057, China
- State Key Laboratory of Chemical Biology and Drug Discovery, Food Safety and Technology Research Centre and Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong SAR, China
| | - Gui-Zhong Xin
- State Key Laboratory of Natural Medicines, Department of Chinese Medicines Analysis, School of Traditional Chinese Pharmacy, China Pharmaceutical University, No. 24 Tongjia Lane, Nanjing, China
| |
Collapse
|
4
|
Ieritano C, Campbell JL, Hopkins WS. Predicting differential ion mobility behaviour in silico using machine learning. Analyst 2021; 146:4737-4743. [PMID: 34212943 DOI: 10.1039/d1an00557j] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Although there has been a surge in popularity of differential mobility spectrometry (DMS) within analytical workflows, determining separation conditions within the DMS parameter space still requires manual optimization. A means of accurately predicting differential ion mobility would benefit practitioners by significantly reducing the time associated with method development. Here, we report a machine learning (ML) approach that predicts dispersion curves in an N2 environment, which are the compensation voltages (CVs) required for optimal ion transmission across a range of separation voltages (SVs) between 1500 to 4000 V. After training a random-forest based model using the DMS information of 409 cationic analytes, dispersion curves were reproduced with a mean absolute error (MAE) of ≤ 2.4 V, approaching typical experimental peak FWHMs of ±1.5 V. The predictive ML model was trained using only m/z and ion-neutral collision cross section (CCS) as inputs, both of which can be obtained from experimental databases before being extensively validated. By updating the model via inclusion of two CV datapoints at lower SVs (1500 V and 2000 V) accuracy was further improved to MAE ≤ 1.2 V. This improvement stems from the ability of the "guided" ML routine to accurately capture Type A and B behaviour, which was exhibited by only 2% and 17% of ions, respectively, within the dataset. Dispersion curve predictions of the database's most common Type C ions (81%) using the unguided and guided approaches exhibited average errors of 0.6 V and 0.1 V, respectively.
Collapse
Affiliation(s)
- Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada. and Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| | - J Larry Campbell
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada. and WaterMine Innovation, Inc., Waterloo, Ontario N0B 2T0, Canada and Bedrock Scientific Inc., Milton, Ontario L6T 6J9, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada. and Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada and WaterMine Innovation, Inc., Waterloo, Ontario N0B 2T0, Canada and Centre for Eye and Vision Research, Hong Kong Science Park, New Territories, 999077, Hong Kong
| |
Collapse
|
5
|
Chang CH, Yeung D, Spicer V, Ogata K, Krokhin O, Ishihama Y. Sequence-Specific Model for Predicting Peptide Collision Cross Section Values in Proteomic Ion Mobility Spectrometry. J Proteome Res 2021; 20:3600-3610. [PMID: 34133192 DOI: 10.1021/acs.jproteome.1c00185] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The contribution of peptide amino acid sequence to collision cross section values (CCS) has been investigated using a dataset of ∼134 000 peptides of four different charge states (1+ to 4+). The migration data were acquired using a two-dimensional liquid chromatography (LC)/trapped ion mobility spectrometry/quadrupole/time-of-flight mass spectrometry (MS) analysis of HeLa cell digests created using seven different proteases and was converted to CCS values. Following the previously reported modeling approaches using intrinsic size parameters (ISP), we extended this methodology to encode the position of individual residues within a peptide sequence. A generalized prediction model was built by dividing the dataset into eight groups (four charges for both tryptic/nontryptic peptides). Position-dependent ISPs were independently optimized for the eight subsets of peptides, resulting in prediction accuracy of ∼0.981 for the entire population of peptides. We find that ion mobility is strongly affected by the peptide's ability to solvate the positively charged sites. Internal positioning of polar residues and proline leads to decreased CCS values as they improve charge solvation; conversely, this ability decreases with increasing peptide charge due to electrostatic repulsion. Furthermore, higher helical propensity and peptide hydrophobicity result in a preferential formation of extended structures with higher than predicted CCS values. Finally, acidic/basic residues exhibit position-dependent ISP behavior consistent with electrostatic interaction with the peptide macrodipole, which affects the peptide helicity. The MS raw data files have been deposited with the ProteomeXchange Consortium via the jPOST partner repository (http://jpostdb.org) with the dataset identifiers PXD021440/JPST000959, PXD022800/JPST001017, and PXD026087/ JPST001176.
Collapse
Affiliation(s)
- Chih-Hsiang Chang
- Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Darien Yeung
- Department of Biochemistry and Medical Genetics, University of Manitoba, Winnipeg, Manitoba R3E 0J9, Canada
- Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, Winnipeg, Manitoba R3E 3P4, Canada
- Department of Internal Medicine, University of Manitoba, Winnipeg, Manitoba R3E 3P4, Canada
| | - Victor Spicer
- Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, Winnipeg, Manitoba R3E 3P4, Canada
| | - Kosuke Ogata
- Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
| | - Oleg Krokhin
- Department of Biochemistry and Medical Genetics, University of Manitoba, Winnipeg, Manitoba R3E 0J9, Canada
- Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, Winnipeg, Manitoba R3E 3P4, Canada
- Department of Internal Medicine, University of Manitoba, Winnipeg, Manitoba R3E 3P4, Canada
- Department of Chemistry, University of Manitoba, 360 Parker Building, Winnipeg, Manitoba R3T 2N2, Canada
| | - Yasushi Ishihama
- Graduate School of Pharmaceutical Sciences, Kyoto University, Kyoto 606-8501, Japan
- Laboratory of Clinical and Analytical Chemistry, National Institute of Biomedical Innovation, Health and Nutrition, Ibaraki, Osaka 567-0085, Japan
| |
Collapse
|
6
|
Ieritano C, Lee A, Crouse J, Bowman Z, Mashmoushi N, Crossley PM, Friebe BP, Campbell JL, Hopkins WS. Determining Collision Cross Sections from Differential Ion Mobility Spectrometry. Anal Chem 2021; 93:8937-8944. [PMID: 34132546 DOI: 10.1021/acs.analchem.1c01420] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
The experimental determination of ion-neutral collision cross sections (CCSs) is generally confined to ion mobility spectrometry (IMS) technologies that operate under the so-called low-field limit or those that enable empirical calibration strategies (e.g., traveling wave IMS; TWIMS). Correlation of ion trajectories to CCS in other non-linear IMS techniques that employ dynamic electric fields, such as differential mobility spectrometry (DMS), has remained a challenge since its inception. Here, we describe how an ion's CCS can be measured from DMS experiments using a machine learning (ML)-based calibration. The differential mobility of 409 molecular cations (m/z: 86-683 Da and CCS 110-236 Å2) was measured in a N2 environment to train the ML framework. Several open-source ML routines were tested and trained using DMS-MS data in the form of the parent ion's m/z and the compensation voltage required for elution at specific separation voltages between 1500 and 4000 V. The best performing ML model, random forest regression, predicted CCSs with a mean absolute percent error of 2.6 ± 0.4% for analytes excluded from the training set (i.e., out-of-the-bag external validation). This accuracy approaches the inherent statistical error of ∼2.2% for the MobCal-MPI CCS calculations employed for training purposes and the <2% threshold for matching literature CCSs with those obtained on a TWIMS platform.
Collapse
Affiliation(s)
- Christian Ieritano
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Arthur Lee
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Jeff Crouse
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
| | - Zack Bowman
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Nour Mashmoushi
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Paige M Crossley
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - Benjamin P Friebe
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
| | - J Larry Campbell
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Bedrock Scientific Inc., Milton, L6T 6J9, Ontario, Canada
| | - W Scott Hopkins
- Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- WaterMine Innovation, Inc., Waterloo N0B 2T0, Ontario, Canada
- Waterloo Institute for Nanotechnology, University of 200 University Avenue West, Waterloo N2L 3G1, Ontario, Canada
- Centre for Eye and Vision Research, Hong Kong Science Park, New Territories 999077, Hong Kong
| |
Collapse
|
7
|
Belova L, Caballero-Casero N, van Nuijs ALN, Covaci A. Ion Mobility-High-Resolution Mass Spectrometry (IM-HRMS) for the Analysis of Contaminants of Emerging Concern (CECs): Database Compilation and Application to Urine Samples. Anal Chem 2021; 93:6428-6436. [PMID: 33845572 DOI: 10.1021/acs.analchem.1c00142] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Ion mobility mass spectrometry (IM-MS)-derived collision cross section (CCS) values can serve as a valuable additional identification parameter within the analysis of compounds of emerging concern (CEC) in human matrices. This study introduces the first comprehensive database of DTCCSN2 values of 148 CECs and their metabolites including bisphenols, alternative plasticizers (AP), organophosphate flame retardants (OP), perfluoroalkyl chemicals (PFAS), and others. A total of 311 ions were included in the database, whereby the DTCCSN2 values for 113 compounds are reported for the first time. For 105 compounds, more than one ion is reported. Moreover, the DTCCSN2 values of several isomeric CECs and their metabolites are reported to allow a distinction between isomers. Comprehensive quality assurance guidelines were implemented in the workflow of acquiring DTCCSN2 values to ensure reproducible experimental conditions. The reliability and reproducibility of the complied database were investigated by analyzing pooled human urine spiked with 30 AP and OP metabolites at two concentration levels. For all investigated metabolites, the DTCCSN2 values measured in urine showed a percent error of <1% in comparison to database values. DTCCSN2 values of OP metabolites showed an average percent error of 0.12% (50 ng/mL in urine) and 0.15% (20 ng/mL in urine). For AP metabolites, these values were 0.10 and 0.09%, respectively. These results show that the provided database can be of great value for enhanced identification of CECs in environmental and human matrices, which can advance future suspect screening studies on CECs.
Collapse
Affiliation(s)
- Lidia Belova
- Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
| | | | | | - Adrian Covaci
- Toxicological Centre, University of Antwerp, Universiteitsplein 1, 2610 Antwerp, Belgium
| |
Collapse
|
8
|
Deep learning the collisional cross sections of the peptide universe from a million experimental values. Nat Commun 2021; 12:1185. [PMID: 33608539 PMCID: PMC7896072 DOI: 10.1038/s41467-021-21352-8] [Citation(s) in RCA: 64] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 01/22/2021] [Indexed: 01/09/2023] Open
Abstract
The size and shape of peptide ions in the gas phase are an under-explored dimension for mass spectrometry-based proteomics. To investigate the nature and utility of the peptide collisional cross section (CCS) space, we measure more than a million data points from whole-proteome digests of five organisms with trapped ion mobility spectrometry (TIMS) and parallel accumulation-serial fragmentation (PASEF). The scale and precision (CV < 1%) of our data is sufficient to train a deep recurrent neural network that accurately predicts CCS values solely based on the peptide sequence. Cross section predictions for the synthetic ProteomeTools peptides validate the model within a 1.4% median relative error (R > 0.99). Hydrophobicity, proportion of prolines and position of histidines are main determinants of the cross sections in addition to sequence-specific interactions. CCS values can now be predicted for any peptide and organism, forming a basis for advanced proteomics workflows that make full use of the additional information. Proteomics has been advanced by algorithms that can predict different peptide features, but predicting peptide collisional cross sections (CCS) has remained challenging. Here, the authors measure over one million CCS values of tryptic peptides and develop a deep learning model for peptide CCS prediction.
Collapse
|
9
|
Ogata K, Chang CH, Ishihama Y. Effect of Phosphorylation on the Collision Cross Sections of Peptide Ions in Ion Mobility Spectrometry. Mass Spectrom (Tokyo) 2021; 10:A0093. [PMID: 33552826 PMCID: PMC7843839 DOI: 10.5702/massspectrometry.a0093] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 12/09/2020] [Indexed: 11/23/2022] Open
Abstract
The insertion of ion mobility spectrometry (IMS) between LC and MS can improve peptide identification in both proteomics and phosphoproteomics by providing structural information that is complementary to LC and MS, because IMS separates ions on the basis of differences in their shapes and charge states. However, it is necessary to know how phosphate groups affect the peptide collision cross sections (CCS) in order to accurately predict phosphopeptide CCS values and to maximize the usefulness of IMS. In this work, we systematically characterized the CCS values of 4,433 pairs of mono-phosphopeptide and corresponding unphosphorylated peptide ions using trapped ion mobility spectrometry (TIMS). Nearly one-third of the mono-phosphopeptide ions evaluated here showed smaller CCS values than their unphosphorylated counterparts, even though phosphorylation results in a mass increase of 80 Da. Significant changes of CCS upon phosphorylation occurred mainly in structurally extended peptides with large numbers of basic groups, possibly reflecting intramolecular interactions between phosphate and basic groups.
Collapse
Affiliation(s)
- Kosuke Ogata
- Department of Molecular and Cellular BioAnalysis, Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606–8501, Japan
| | - Chih-Hsiang Chang
- Department of Molecular and Cellular BioAnalysis, Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606–8501, Japan
| | - Yasushi Ishihama
- Department of Molecular and Cellular BioAnalysis, Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606–8501, Japan
| |
Collapse
|
10
|
Mesa Sanchez D, Creger S, Singla V, Kurulugama RT, Fjeldsted J, Laskin J. Ion Mobility-Mass Spectrometry Imaging Workflow. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2437-2442. [PMID: 32841564 DOI: 10.1021/jasms.0c00142] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Mass spectrometry imaging (MSI) is a powerful technique for the label-free spatially resolved analysis of biological tissues. Coupling ion mobility (IM) separation with MSI allows for separation of isobars in the mobility dimension and increases confidence of peak assignments. Recently, imaging experiments have been implemented on several commercially available and custom-designed ion mobility instruments, making IM-MSI experiments more broadly accessible to the MS community. However, the absence of open access data analysis software for IM-MSI systems presents a bottleneck. Herein, we present an imaging workflow to visualize IM-MSI data produced on the Agilent 6560 ion mobility quadrupole time-of-flight system. Specifically, we have developed a Python script, the ion mobility-mass spectrometry image creation script (IM-MSIC), which interfaces Agilent's Mass Hunter Mass Profiler software with the MacCoss lab's Skyline software and generates drift time and mass-to-charge-selected ion images. In the workflow, Mass Profiler is used for an untargeted feature detection. The IM-MSIC script mediates user input of data, extracts ion chronograms utilizing Skyline's command-line interface, and then proceeds toward ion image generation within a single user interface. Ion image postprocessing is subsequently performed using different tools implemented in accompanying scripts. Though the current work only showcases Agilent IM-MSI data, this workflow can be readily adapted for use with most major instrument vendors.
Collapse
Affiliation(s)
- Daniela Mesa Sanchez
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47906, United States
| | - Steve Creger
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47906, United States
| | - Veerupaksh Singla
- Department of Chemical Engineering, Indian Institute of Technology Bombay, Powai, Mumbai, Maharashtra 400076, India
| | | | - John Fjeldsted
- Agilent Technologies Inc., Santa Clara, California 95051, United States
| | - Julia Laskin
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47906, United States
| |
Collapse
|
11
|
Li A, Conant CR, Zheng X, Bloodsworth KJ, Orton DJ, Garimella SVB, Attah IK, Nagy G, Smith RD, Ibrahim YM. Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations. Anal Chem 2020; 92:14976-14982. [PMID: 33136380 DOI: 10.1021/acs.analchem.0c02829] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling wave ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20, 25, and 30 V0-p). The calibration errors for the three calibrant sets (Agilent tuning mixture, polyalanine, and one assembled in-house) showed negligible differences using a sine-shaped TW waveform. Calibration errors were all within 1-2% of the drift tube ion mobility spectrometry (DTIMS) measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh-resolution multipass (long path length) SLIM TWIMS separations demonstrated improved CCS calibration for phospholipid and bile acid isomers.
Collapse
Affiliation(s)
- Ailin Li
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Christopher R Conant
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Xueyun Zheng
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Kent J Bloodsworth
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Daniel J Orton
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Sandilya V B Garimella
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Isaac K Attah
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Gabe Nagy
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Richard D Smith
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| | - Yehia M Ibrahim
- Biological Sciences Division, Pacific Northwest National Laboratory, Richland, Washington 99354, United States
| |
Collapse
|
12
|
The use of UHPLC, IMS, and HRMS in multiresidue analytical methods: A critical review. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1158:122369. [PMID: 33091675 DOI: 10.1016/j.jchromb.2020.122369] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 08/31/2020] [Accepted: 09/02/2020] [Indexed: 12/12/2022]
Abstract
Residue chemists who analyse pesticides in vegetables or veterinary drugs in animal-based food are currently facing a situation where there is a requirement to detect more and more compounds at lower and lower concentrations. Conventional tandem quadrupole instruments provide sufficient sensitivity, but speed and selectivity appear as future limitations. This will become an even larger issue when there is a need to not only detect active compounds but also their degradation products and metabolites. This will likely lead to a situation in which the conventional targeted approach must be expanded or augmented by a certain non-targeted strategy. High-resolution mass spectrometry provides such capabilities, but it frequently requires an additional degree of selectivity for the unequivocal confirmation of analytes present at trace levels in highly complex and variable food matrices. The hyphenation of ultrahigh performance liquid chromatography with ion mobility and high-resolution mass spectrometry provides analytical chemists with a new tool for performing such a demanding multiresidue analysis. The objective of this paper is to investigate the benefits of the added ion mobility dimension as well as to critically discuss the current limitations of this commercially available technology.
Collapse
|
13
|
Kaufmann A, Butcher P, Maden K, Walker S, Widmer M. Does the ion mobility resolving power as provided by commercially available ion mobility quadrupole time-of-flight mass spectrometry instruments permit the unambiguous identification of small molecules in complex matrices? Anal Chim Acta 2020; 1107:113-126. [DOI: 10.1016/j.aca.2020.02.032] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 02/10/2020] [Accepted: 02/14/2020] [Indexed: 12/17/2022]
|
14
|
DeLaney K, Li L. Data Independent Acquisition Mass Spectrometry Method for Improved Neuropeptidomic Coverage in Crustacean Neural Tissue Extracts. Anal Chem 2019; 91:5150-5158. [PMID: 30888792 PMCID: PMC6481171 DOI: 10.1021/acs.analchem.8b05734] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Neuropeptides are an important class of signaling molecules in the nervous and neuroendocrine system, but they are challenging to study due to their low concentration in vivo in the presence of numerous interfering artifacts. Often the limitation of mass spectrometry analyses of neuropeptides in complex tissue extracts is not due to neuropeptides being below the detection limit but due to ions not being selected for tandem mass spectrometry during the liquid chromatography elution time and therefore not being identified. In this study, a data independent acquisition (DIA) method was developed to improve the coverage of neuropeptides in neural tissue from the model organism C. borealis. The optimal mass-to-charge ratio range and isolation window were determined and subsequently used to detect more neuropeptides in extracts from the brain and pericardial organs than the conventional data dependent acquisition method. The DIA method led to the detection of almost twice as many neuropeptides in the brain and approximately 1.5-fold more neuropeptides in the pericardial organs. The technical and biological reproducibility were also explored and found to be improved over the original method, with 56% of neuropeptides detected in 3 out of 3 replicate injections and 62% in 3 out of 3 biological replicates. Furthermore, 68 putative novel neuropeptides were detected and identified with de novo sequencing. The quantitative accuracy of the method was also explored. The developed method is anticipated to be useful for gaining a deeper profiling of neuropeptides, especially those in low abundance, in a variety of sample types.
Collapse
Affiliation(s)
- Kellen DeLaney
- Department of Chemistry, University of Wisconsin–Madison, 1101 University Avenue, Madison, Wisconsin 53706-1322, United States
| | - Lingjun Li
- Department of Chemistry, University of Wisconsin–Madison, 1101 University Avenue, Madison, Wisconsin 53706-1322, United States
- School of Pharmacy, University of Wisconsin–Madison, 5125 Rennebohm Hall, 777 Highland Avenue, Madison, Wisconsin 53705-2222, United States
| |
Collapse
|
15
|
Picache JA, Rose BS, Balinski A, Leaptrot KL, Sherrod SD, May JC, McLean JA. Collision cross section compendium to annotate and predict multi-omic compound identities. Chem Sci 2019; 10:983-993. [PMID: 30774892 PMCID: PMC6349024 DOI: 10.1039/c8sc04396e] [Citation(s) in RCA: 180] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Accepted: 11/21/2018] [Indexed: 01/01/2023] Open
Abstract
Ion mobility mass spectrometry (IM-MS) expands the analyte coverage of existing multi-omic workflows by providing an additional separation dimension as well as a parameter for characterization and identification of molecules - the collision cross section (CCS). This work presents a large, Unified CCS compendium of >3800 experimentally acquired CCS values obtained from traceable molecular standards and measured with drift tube ion mobility-mass spectrometers. An interactive visualization of this compendium along with data analytic tools have been made openly accessible. Represented in the compendium are 14 structurally-based chemical super classes, consisting of a total of 80 classes and 157 subclasses. Using this large data set, regression fitting and predictive statistics have been performed to describe mass-CCS correlations specific to each chemical ontology. These structural trends provide a rapid and effective filtering method in the traditional untargeted workflow for identification of unknown biochemical species. The utility of the approach is illustrated by an application to metabolites in human serum, quantified trends of which were used to assess the probability of an unknown compound belonging to a given class. CCS-based filtering narrowed the chemical search space by 60% while increasing the confidence in the remaining isomeric identifications from a single class, thus demonstrating the value of integrating predictive analyses into untargeted experiments to assist in identification workflows. The predictive abilities of this compendium will improve in specificity and expand to more chemical classes as additional data from the IM-MS community is contributed. Instructions for data submission to the compendium and criteria for inclusion are provided.
Collapse
Affiliation(s)
- Jaqueline A Picache
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| | - Bailey S Rose
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| | - Andrzej Balinski
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| | - Katrina L Leaptrot
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| | - Stacy D Sherrod
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| | - Jody C May
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| | - John A McLean
- Department of Chemistry , Center for Innovative Technology , Vanderbilt Institute of Chemical Biology , Vanderbilt Institute for Integrative Biosystems Research and Education , Vanderbilt-Ingram Cancer Center , Vanderbilt University , Nashville , Tennessee 37235 , USA .
| |
Collapse
|
16
|
Meier F, Brunner AD, Koch S, Koch H, Lubeck M, Krause M, Goedecke N, Decker J, Kosinski T, Park MA, Bache N, Hoerning O, Cox J, Räther O, Mann M. Online Parallel Accumulation-Serial Fragmentation (PASEF) with a Novel Trapped Ion Mobility Mass Spectrometer. Mol Cell Proteomics 2018; 17:2534-2545. [PMID: 30385480 PMCID: PMC6283298 DOI: 10.1074/mcp.tir118.000900] [Citation(s) in RCA: 523] [Impact Index Per Article: 87.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 10/30/2018] [Indexed: 11/06/2022] Open
Abstract
In bottom-up proteomics, peptides are separated by liquid chromatography with elution peak widths in the range of seconds, whereas mass spectra are acquired in about 100 microseconds with time-of-flight (TOF) instruments. This allows adding ion mobility as a third dimension of separation. Among several formats, trapped ion mobility spectrometry (TIMS) is attractive because of its small size, low voltage requirements and high efficiency of ion utilization. We have recently demonstrated a scan mode termed parallel accumulation - serial fragmentation (PASEF), which multiplies the sequencing speed without any loss in sensitivity (Meier et al., PMID: 26538118). Here we introduce the timsTOF Pro instrument, which optimally implements online PASEF. It features an orthogonal ion path into the ion mobility device, limiting the amount of debris entering the instrument and making it very robust in daily operation. We investigate different precursor selection schemes for shotgun proteomics to optimally allocate in excess of 100 fragmentation events per second. More than 600,000 fragmentation spectra in standard 120 min LC runs are achievable, which can be used for near exhaustive precursor selection in complex mixtures or accumulating the signal of weak precursors. In 120 min single runs of HeLa digest, MaxQuant identified more than 6,000 proteins without matching to a library and with high quantitative reproducibility (R > 0.97). Online PASEF achieves a remarkable sensitivity with more than 2,500 proteins identified in 30 min runs of only 10 ng HeLa digest. We also show that highly reproducible collisional cross sections can be acquired on a large scale (R > 0.99). PASEF on the timsTOF Pro is a valuable addition to the technological toolbox in proteomics, with a number of unique operating modes that are only beginning to be explored.
Collapse
Affiliation(s)
- Florian Meier
- Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Andreas-David Brunner
- Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Scarlet Koch
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Heiner Koch
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Markus Lubeck
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Michael Krause
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Niels Goedecke
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Jens Decker
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Thomas Kosinski
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Melvin A Park
- Bruker Daltonics Inc., Manning Road, Billerica, Massachusetts 01821
| | - Nicolai Bache
- Evosep Biosystems, Thriges Pl. 6, 5000 Odense, Denmark
| | - Ole Hoerning
- Evosep Biosystems, Thriges Pl. 6, 5000 Odense, Denmark
| | - Jürgen Cox
- Computational Systems Biochemistry, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany
| | - Oliver Räther
- Bruker Daltonik GmbH, Fahrenheitstr. 4, 28359 Bremen, Germany
| | - Matthias Mann
- Proteomics and Signal Transduction, Max Planck Institute of Biochemistry, Am Klopferspitz 18, 82152 Martinsried, Germany; NNF Center for Protein Research, Faculty of Health Sciences, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen, Denmark.
| |
Collapse
|
17
|
Baksi A, Chakraborty P, Nag A, Ghosh D, Bhat S, Pradeep T. Monolayer-Protected Noble-Metal Clusters as Potential Standards for Negative-Ion Mass Spectrometry. Anal Chem 2018; 90:11351-11357. [DOI: 10.1021/acs.analchem.8b02280] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Ananya Baksi
- DST Unit of Nanoscience and Thematic Unit of Excellence, Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Papri Chakraborty
- DST Unit of Nanoscience and Thematic Unit of Excellence, Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Abhijit Nag
- DST Unit of Nanoscience and Thematic Unit of Excellence, Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Debasmita Ghosh
- DST Unit of Nanoscience and Thematic Unit of Excellence, Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Shridevi Bhat
- DST Unit of Nanoscience and Thematic Unit of Excellence, Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| | - Thalappil Pradeep
- DST Unit of Nanoscience and Thematic Unit of Excellence, Department of Chemistry, Indian Institute of Technology Madras, Chennai 600036, India
| |
Collapse
|
18
|
Maleki H, Karanji AK, Majuta S, Maurer MM, Valentine SJ. Ion Mobility Spectrometry-Mass Spectrometry Coupled with Gas-Phase Hydrogen/Deuterium Exchange for Metabolomics Analyses. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:230-241. [PMID: 28956290 PMCID: PMC5942887 DOI: 10.1007/s13361-017-1798-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 08/22/2017] [Accepted: 08/26/2017] [Indexed: 05/11/2023]
Abstract
Ion mobility spectrometry-mass spectrometry (IMS-MS) in combination with gas-phase hydrogen/deuterium exchange (HDX) and collision-induced dissociation (CID) is evaluated as an analytical method for small-molecule standard and mixture characterization. Experiments show that compound ions exhibit unique HDX reactivities that can be used to distinguish different species. Additionally, it is shown that gas-phase HDX kinetics can be exploited to provide even further distinguishing capabilities by using different partial pressures of reagent gas. The relative HDX reactivity of a wide variety of molecules is discussed in light of the various molecular structures. Additionally, hydrogen accessibility scoring (HAS) and HDX kinetics modeling of candidate (in silico) ion structures is utilized to estimate the relative ion conformer populations giving rise to specific HDX behavior. These data interpretation methods are discussed with a focus on developing predictive tools for HDX behavior. Finally, an example is provided in which ion mobility information is supplemented with HDX reactivity data to aid identification efforts of compounds in a metabolite extract. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Hossein Maleki
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | - Ahmad K Karanji
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | - Sandra Majuta
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | - Megan M Maurer
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA
| | - Stephen J Valentine
- C. Eugene Bennett Department of Chemistry, West Virginia University, Morgantown, WV, 26506, USA.
| |
Collapse
|
19
|
DeLaney K, Buchberger A, Li L. Identification, Quantitation, and Imaging of the Crustacean Peptidome. Methods Mol Biol 2018; 1719:247-269. [PMID: 29476517 DOI: 10.1007/978-1-4939-7537-2_17] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Crustaceans serve as a useful, simplified model for studying peptides and neuromodulation, as they contain numerous neuropeptide homologs to mammals and enable electrophysiological studies at the single-cell and neural circuit levels. In particular, crustaceans contain well-defined neural networks, including the stomatogastric ganglion, esophageal ganglion, commissural ganglia, and several neuropeptide-rich organs, such as the brain, pericardial organs, and sinus glands. Due to the lack of a genomic database for crustacean peptides, an important step of crustacean peptidomics involves the discovery and identification of novel peptides and the construction of a database, more recently with the aid of mass spectrometry (MS). Herein, we present a general workflow and detailed methods for MS-based peptidomic analysis of crustacean tissue samples and circulating fluids. In conjunction with profiling, quantitation can also be performed with isotopic or isobaric labeling. Information regarding the localization patterns and changes of peptides can be studied via mass spectrometry imaging. Combining these sample preparation strategies and MS analytical techniques allows for a multifaceted approach to obtaining deep knowledge of crustacean peptidergic signaling pathways.
Collapse
Affiliation(s)
- Kellen DeLaney
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, USA
| | - Amanda Buchberger
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, USA
| | - Lingjun Li
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, USA. .,School of Pharmacy, University of Wisconsin-Madison, Madison, WI, USA.
| |
Collapse
|
20
|
Abstract
In this review, we focus on an important aspect of ion mobility (IM) research, namely the reporting of quantitative ion mobility measurements in the form of the gas-phase collision cross section (CCS), which has provided a common basis for comparison across different instrument platforms and offers a unique form of structural information, namely size and shape preferences of analytes in the absence of bulk solvent. This review surveys the over 24,000 CCS values reported from IM methods spanning the era between 1975 to 2015, which provides both a historical and analytical context for the contributions made thus far, as well as insight into the future directions that quantitative ion mobility measurements will have in the analytical sciences. The analysis was conducted in 2016, so CCS values reported in that year are purposely omitted. In another few years, a review of this scope will be intractable, as the number of CCS values which will be reported in the next three to five years is expected to exceed the total amount currently published in the literature.
Collapse
Affiliation(s)
- Jody C May
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - Caleb B Morris
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University , Nashville, Tennessee 37235, United States
| |
Collapse
|
21
|
Allen SJ, Bush MF. Radio-Frequency (rf) Confinement in Ion Mobility Spectrometry: Apparent Mobilities and Effective Temperatures. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:2054-2063. [PMID: 27582119 DOI: 10.1007/s13361-016-1479-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Revised: 08/08/2016] [Accepted: 08/11/2016] [Indexed: 06/06/2023]
Abstract
Ion mobility is a powerful tool for separating and characterizing the structures of ions. Here, a radio-frequency (rf) confining drift cell is used to evaluate the drift times of ions over a broad range of drift field strengths (E/P, V cm-1 Torr-1). The presence of rf potentials radially confines ions and results in excellent ion transmission at low E/P (less than 1 V cm-1 Torr-1), thereby reducing the dependence of ion transmission on the applied drift voltage. Non-linear responses between drift time and reciprocal drift voltages are observed for extremely low E/P and high rf amplitudes. Under these conditions, pseudopotential wells generated by the rf potentials dampen the mobility of ions. The effective potential approximation is used to characterize this mobility dampening behavior, which can be mitigated by adjusting rf amplitudes and electrode dimensions. Using SIMION trajectories and statistical arguments, the effective temperatures of ions in an rf-confining drift cell are evaluated. Results for the doubly charged peptide GRGDS suggest that applied rf potentials can result in a subtle increase (2 K) in effective temperature compared to an electrostatic drift tube. Additionally, simulations of native-like ions of the protein complex avidin suggest that rf potentials have a negligible effect on the effective temperature of these ions. In general, the results of this study suggest that applied rf potentials enable the measurement of drift times at extremely low E/P and that these potentials have negligible effects on ion effective temperature. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Samuel J Allen
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA, 98195-1700, USA
| | - Matthew F Bush
- Department of Chemistry, University of Washington, Box 351700, Seattle, WA, 98195-1700, USA.
| |
Collapse
|
22
|
Zhou Z, Shen X, Tu J, Zhu ZJ. Large-Scale Prediction of Collision Cross-Section Values for Metabolites in Ion Mobility-Mass Spectrometry. Anal Chem 2016; 88:11084-11091. [DOI: 10.1021/acs.analchem.6b03091] [Citation(s) in RCA: 133] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Zhiwei Zhou
- Interdisciplinary
Research
Center on Biology and Chemistry and Shanghai
Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, 200032 P. R. China
| | - Xiaotao Shen
- Interdisciplinary
Research
Center on Biology and Chemistry and Shanghai
Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, 200032 P. R. China
| | - Jia Tu
- Interdisciplinary
Research
Center on Biology and Chemistry and Shanghai
Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, 200032 P. R. China
| | - Zheng-Jiang Zhu
- Interdisciplinary
Research
Center on Biology and Chemistry and Shanghai
Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai, 200032 P. R. China
| |
Collapse
|
23
|
Pepin R, Laszlo KJ, Marek A, Peng B, Bush MF, Lavanant H, Afonso C, Tureček F. Toward a Rational Design of Highly Folded Peptide Cation Conformations. 3D Gas-Phase Ion Structures and Ion Mobility Characterization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:1647-60. [PMID: 27400696 PMCID: PMC5031493 DOI: 10.1007/s13361-016-1437-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2016] [Revised: 05/27/2016] [Accepted: 06/16/2016] [Indexed: 05/18/2023]
Abstract
Heptapeptide ions containing combinations of polar Lys, Arg, and Asp residues with non-polar Leu, Pro, Ala, and Gly residues were designed to study polar effects on gas-phase ion conformations. Doubly and triply charged ions were studied by ion mobility mass spectrometry and electron structure theory using correlated ab initio and density functional theory methods and found to exhibit tightly folded 3D structures in the gas phase. Manipulation of the basic residue positions in LKGPADR, LRGPADK, KLGPADR, and RLGPADK resulted in only minor changes in the ion collision cross sections in helium. Replacement of the Pro residue with Leu resulted in only marginally larger collision cross sections for the doubly and triply charged ions. Disruption of zwitterionic interactions in doubly charged ions was performed by converting the C-terminal and Asp carboxyl groups to methyl esters. This resulted in very minor changes in the collision cross sections of doubly charged ions and even slightly diminished collision cross sections in most triply charged ions. The experimental collision cross sections were related to those calculated for structures of lowest free energy ion conformers that were obtained by extensive search of the conformational space and fully optimized by density functional theory calculations. The predominant factors that affected ion structures and collision cross sections were due to attractive hydrogen bonding interactions and internal solvation of the charged groups that overcompensated their Coulomb repulsion. Structure features typically assigned to the Pro residue and zwitterionic COO-charged group interactions were only secondary in affecting the structures and collision cross sections of these gas-phase peptide ions. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Robert Pepin
- Department of Chemistry, Bagley Hall, University of Washington, Seattle, WA, USA
| | - Kenneth J Laszlo
- Department of Chemistry, Bagley Hall, University of Washington, Seattle, WA, USA
| | - Aleš Marek
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic
| | - Bo Peng
- Department of Chemistry, Bagley Hall, University of Washington, Seattle, WA, USA
| | - Matthew F Bush
- Department of Chemistry, Bagley Hall, University of Washington, Seattle, WA, USA
| | - Helène Lavanant
- Laboratoire COBRA CNRS UMR 6014 & FR 3038, Université de Rouen, INSA de Rouen, Mont St Aignan Cedex, France
| | - Carlos Afonso
- Laboratoire COBRA CNRS UMR 6014 & FR 3038, Université de Rouen, INSA de Rouen, Mont St Aignan Cedex, France
| | - František Tureček
- Department of Chemistry, Bagley Hall, University of Washington, Seattle, WA, USA.
| |
Collapse
|
24
|
Lietz CB, Chen Z, Yun Son C, Pang X, Cui Q, Li L. Multiple gas-phase conformations of proline-containing peptides: is it always cis/trans isomerization? Analyst 2016; 141:4863-9. [PMID: 27434776 PMCID: PMC4972606 DOI: 10.1039/c5an00835b] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Ion mobility-mass spectrometry (IM-MS) is often employed to look at the secondary, tertiary, and quaternary structures of naked peptides and proteins in the gas-phase. Recently, it has offered a unique glimpse into proline-containing peptides and their cis/trans Xxx-Pro isomers. An experimental "signature" has been identified wherein a proline-containing peptide has its Pro residues substituted with another amino acid and the presence or absence of conformations in the IM-MS spectra is observed. Despite the high probability that one could attribute these conformations to cis/trans isomers, it is also possible that cis/trans isomers are not the cause of the additional conformations in proline-containing peptides. However, the experimental evidence of such a system has not been demonstrated or reported. Herein, we present the IM-MS analysis of Neuropeptide Y's wild-type (WT) signal sequence and Leu7Pro (L7P) mutant. Although comparison of arrival times and collision cross-sections of [M + 4H](4+) ions yields the cis/trans "signature", molecular dynamics indicates that a cis-Pro7 is not very stable and that trans-Pro7 conformations of the same cross-section arise with equal frequency. We believe that this work further underscores the importance of theoretical calculations in IM-MS structural assignments.
Collapse
Affiliation(s)
- Christopher B Lietz
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA.
| | - Zhengwei Chen
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA.
| | - Chang Yun Son
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA.
| | - Xueqin Pang
- School of Pharmacy, University of Wisconsin-Madison, 777 Highland Avenue, Madison, WI 53705, USA
| | - Qiang Cui
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA.
| | - Lingjun Li
- Department of Chemistry, University of Wisconsin-Madison, 1101 University Avenue, Madison, WI 53706, USA. and School of Pharmacy, University of Wisconsin-Madison, 777 Highland Avenue, Madison, WI 53705, USA
| |
Collapse
|
25
|
Pepin R, Petrone A, Laszlo KJ, Bush MF, Li X, Tureček F. Does Thermal Breathing Affect Collision Cross Sections of Gas-Phase Peptide Ions? An Ab Initio Molecular Dynamics Study. J Phys Chem Lett 2016; 7:2765-71. [PMID: 27389035 PMCID: PMC5032842 DOI: 10.1021/acs.jpclett.6b01187] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Ab initio molecular dynamics (AIMD) with density functional theory (DFT) was applied to explore conformational motions and collision cross sections (Ω) of folded (2) and extended (7) conformers of doubly charged peptide ions, (Ala-Ala-Leu-Arg + 2H)(2+), in the gas phase at 300 and 473 K. The experimental Ω of (Ala-Ala-Leu-Arg +2H)(2+) was measured as 149 ± 1.2 Å(2) at 298 K. Thermally distributed mean values of Ω for 2 and 7 at 300 and 473 K were only 0.8-1.1% larger than for the equilibrium 0 K structures. Long (>10 ps) trajectory calculations indicated entropy-driven conformational change of 2 to 7 that occurred at random within a ∼ 4 ps time window. The experimental Ω was found to fit the calculated population averaged values for 2 and 7, indicating a rapid conformer interconversion. Overall, thermal breathing had only a minor effect on the peptide ion collision cross sections.
Collapse
|
26
|
May JC, McLean JA. Advanced Multidimensional Separations in Mass Spectrometry: Navigating the Big Data Deluge. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2016; 9:387-409. [PMID: 27306312 PMCID: PMC5763907 DOI: 10.1146/annurev-anchem-071015-041734] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Hybrid analytical instrumentation constructed around mass spectrometry (MS) is becoming the preferred technique for addressing many grand challenges in science and medicine. From the omics sciences to drug discovery and synthetic biology, multidimensional separations based on MS provide the high peak capacity and high measurement throughput necessary to obtain large-scale measurements used to infer systems-level information. In this article, we describe multidimensional MS configurations as technologies that are big data drivers and review some new and emerging strategies for mining information from large-scale datasets. We discuss the information content that can be obtained from individual dimensions, as well as the unique information that can be derived by comparing different levels of data. Finally, we summarize some emerging data visualization strategies that seek to make highly dimensional datasets both accessible and comprehensible.
Collapse
Affiliation(s)
- Jody C May
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, Tennessee 37235;
| | - John A McLean
- Department of Chemistry, Center for Innovative Technology, Vanderbilt Institute for Chemical Biology, Vanderbilt Institute for Integrative Biosystems Research and Education, Vanderbilt University, Nashville, Tennessee 37235;
| |
Collapse
|
27
|
Forsythe JG, Petrov AS, Walker CA, Allen SJ, Pellissier JS, Bush MF, Hud NV, Fernández FM. Collision cross section calibrants for negative ion mode traveling wave ion mobility-mass spectrometry. Analyst 2016; 140:6853-61. [PMID: 26148962 DOI: 10.1039/c5an00946d] [Citation(s) in RCA: 74] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Unlike traditional drift-tube ion mobility-mass spectrometry, traveling-wave ion mobility-mass spectrometry typically requires calibration in order to generate collision cross section (CCS) values. Although this has received a significant amount of attention for positive-ion mode analysis, little attention has been paid for CCS calibration in negative ion mode. Here, we provide drift-tube CCS values for [M - H](-) ions of two calibrant series, polyalanine and polymalic acid, and evaluate both types of calibrants in terms of the accuracy and precision of the traveling-wave ion mobility CCS values that they produce.
Collapse
|
28
|
Sun Y, Vahidi S, Sowole MA, Konermann L. Protein Structural Studies by Traveling Wave Ion Mobility Spectrometry: A Critical Look at Electrospray Sources and Calibration Issues. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:31-40. [PMID: 26369778 DOI: 10.1007/s13361-015-1244-5] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2015] [Revised: 07/27/2015] [Accepted: 07/29/2015] [Indexed: 06/05/2023]
Abstract
The question whether electrosprayed protein ions retain solution-like conformations continues to be a matter of debate. One way to address this issue involves comparisons of collision cross sections (Ω) measured by ion mobility spectrometry (IMS) with Ω values calculated for candidate structures. Many investigations in this area employ traveling wave IMS (TWIMS). It is often implied that nanoESI is more conducive for the retention of solution structure than regular ESI. Focusing on ubiquitin, cytochrome c, myoglobin, and hemoglobin, we demonstrate that Ω values and collisional unfolding profiles are virtually indistinguishable under both conditions. These findings suggest that gas-phase structures and ion internal energies are independent of the type of electrospray source. We also note that TWIMS calibration can be challenging because differences in the extent of collisional activation relative to drift tube reference data may lead to ambiguous peak assignments. It is demonstrated that this problem can be circumvented by employing collisionally heated calibrant ions. Overall, our data are consistent with the view that exposure of native proteins to electrospray conditions can generate kinetically trapped ions that retain solution-like structures on the millisecond time scale of TWIMS experiments. ᅟ
Collapse
Affiliation(s)
- Yu Sun
- Department of Chemistry, The University of Western Ontario, London, ON, N6A 5B7, Canada
| | - Siavash Vahidi
- Department of Chemistry, The University of Western Ontario, London, ON, N6A 5B7, Canada
| | - Modupeola A Sowole
- Department of Chemistry, The University of Western Ontario, London, ON, N6A 5B7, Canada
| | - Lars Konermann
- Department of Chemistry, The University of Western Ontario, London, ON, N6A 5B7, Canada.
| |
Collapse
|
29
|
Jia C, Lietz CB, Yu Q, Li L. Site-specific Localization of D-Amino Acids in Bioactive Peptides by Ion Mobility Spectrometry. ANALYSIS OF POST-TRANSLATIONAL MODIFICATIONS AND PROTEOLYSIS IN NEUROSCIENCE 2016. [DOI: 10.1007/7657_2015_82] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
30
|
Doneanu CE, Anderson M, Williams BJ, Lauber MA, Chakraborty A, Chen W. Enhanced Detection of Low-Abundance Host Cell Protein Impurities in High-Purity Monoclonal Antibodies Down to 1 ppm Using Ion Mobility Mass Spectrometry Coupled with Multidimensional Liquid Chromatography. Anal Chem 2015; 87:10283-91. [DOI: 10.1021/acs.analchem.5b02103] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Catalin E. Doneanu
- Waters Corporation, 34 Maple
Street, Milford, Massachusetts 01757, United States
| | - Malcolm Anderson
- Waters Corporation, Stamford
Avenue, Altrincham Road, Wilmslow, SK9 4AX, U.K
| | - Brad J. Williams
- Waters Corporation, 100 Cummings
Center, Suite 407N, Beverly, Massachusetts 01915, United States
| | - Matthew A. Lauber
- Waters Corporation, 34 Maple
Street, Milford, Massachusetts 01757, United States
| | - Asish Chakraborty
- Waters Corporation, 34 Maple
Street, Milford, Massachusetts 01757, United States
| | - Weibin Chen
- Waters Corporation, 34 Maple
Street, Milford, Massachusetts 01757, United States
| |
Collapse
|
31
|
Affiliation(s)
- Jody C. May
- Department
of Chemistry,
Center for Innovative Technology, Vanderbilt Institute for Chemical
Biology, Vanderbilt Institute for Integrative Biosystems Research
and Education , Vanderbilt University, Nashville, Tennessee 37235, United States
| | - John A. McLean
- Department
of Chemistry,
Center for Innovative Technology, Vanderbilt Institute for Chemical
Biology, Vanderbilt Institute for Integrative Biosystems Research
and Education , Vanderbilt University, Nashville, Tennessee 37235, United States
| |
Collapse
|
32
|
Greer T, Lietz CB, Xiang F, Li L. Novel isotopic N,N-dimethyl leucine (iDiLeu) reagents enable absolute quantification of peptides and proteins using a standard curve approach. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:107-19. [PMID: 25377360 PMCID: PMC4276538 DOI: 10.1007/s13361-014-1012-y] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2014] [Revised: 09/20/2014] [Accepted: 09/23/2014] [Indexed: 05/23/2023]
Abstract
Absolute quantification of protein targets using liquid chromatography-mass spectrometry (LC-MS) is a key component of candidate biomarker validation. One popular method combines multiple reaction monitoring (MRM) using a triple quadrupole instrument with stable isotope-labeled standards (SIS) for absolute quantification (AQUA). LC-MRM AQUA assays are sensitive and specific, but they are also expensive because of the cost of synthesizing stable isotope peptide standards. While the chemical modification approach using mass differential tags for relative and absolute quantification (mTRAQ) represents a more economical approach when quantifying large numbers of peptides, these reagents are costly and still suffer from lower throughput because only two concentration values per peptide can be obtained in a single LC-MS run. Here, we have developed and applied a set of five novel mass difference reagents, isotopic N,N-dimethyl leucine (iDiLeu). These labels contain an amine reactive group, triazine ester, are cost effective because of their synthetic simplicity, and have increased throughput compared with previous LC-MS quantification methods by allowing construction of a four-point standard curve in one run. iDiLeu-labeled peptides show remarkably similar retention time shifts, slightly lower energy thresholds for higher-energy collisional dissociation (HCD) fragmentation, and high quantification accuracy for trypsin-digested protein samples (median errors <15%). By spiking in an iDiLeu-labeled neuropeptide, allatostatin, into mouse urine matrix, two quantification methods are validated. The first uses one labeled peptide as an internal standard to normalize labeled peptide peak areas across runs (<19% error), whereas the second enables standard curve creation and analyte quantification in one run (<8% error).
Collapse
Affiliation(s)
- Tyler Greer
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706, United States
| | - Christopher B. Lietz
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706, United States
| | - Feng Xiang
- School of Pharmacy, University of Wisconsin-School of Madison, Madison, WI, 53705, United States
| | - Lingjun Li
- Department of Chemistry, University of Wisconsin-Madison, Madison, WI, 53706, United States
- School of Pharmacy, University of Wisconsin-School of Madison, Madison, WI, 53705, United States
| |
Collapse
|