Zhan L, Chen G, Li K. Quantifying photon counting detector (PCD) performance using PCD-CT images. Med Phys 2025; 52:2796-2809. [PMID: 39971720 PMCID: PMC12064383 DOI: 10.1002/mp.17701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2024] [Revised: 02/05/2025] [Accepted: 02/09/2025] [Indexed: 02/21/2025] Open
Abstract
BACKGROUND Photon counting detector CTs (PCD-CTs) have recently been introduced to clinical imaging. This development creates a new need for end-users to quantify and monitor the physical performance of PCDs. Traditionally, the characterization of PCD performance relied on detector counts, which are typically accessible to the manufacturer but are not usually available to clinical end-users. PURPOSE The goal of this work was to develop a new method for quantifying PCD performance using reconstructed PCD-CT images, without requiring access to the PCD counts. METHODS The proposed method is based on a set of closed-form relationships that connect PCD-CT image noise, the PCD deadtime ( τ $\tau$ ), and the zero-frequency detective quantum efficiency (DQE 0 ${\rm DQE}_0$ ) of PCDs. At a low tube current (mA) level, the mean output counts of the PCD were estimated by fitting the measured PCD-CT noise power spectrum (NPS) to a parametric model.DQE 0 ${\rm DQE}_0$ was then calculated by normalizing the estimated mean detector counts to the expected input x-ray photon number. To estimate τ $\tau$ , the image variance of PCD-CT was measured at different mA levels. A novel quantitative relationship between PCD-CT image variance, τ $\tau$ , and mA was employed to estimate τ $\tau$ through parametric fitting. The method was validated using both simulated and experimental PCD-CT data, covering a range of τ $\tau$ ,DQE 0 ${\rm DQE}_0$ , and system geometries. RESULTS For the simulated curved-detector PCD-CT, the estimation errors forDQE 0 ${\rm DQE}_0$ and deadtime were -3.7% and 0.5%, respectively. For the simulated collinear-detector PCD-CT, the estimation errors forDQE 0 ${\rm DQE}_0$ and deadtime were -3.3% and -1.0%, respectively. For the experimental collinear-detector PCD-CT, the estimation errors forDQE 0 ${\rm DQE}_0$ and deadtime were -2.6% and 1.6%, respectively. CONCLUSIONS By analyzing the variance and NPS of PCD-CT images,DQE 0 ${\rm DQE}_0$ and deadtime of scanner's PCD can be accurately estimated, without access to raw detector counts or projection data.
Collapse
Affiliation(s)
- Linying Zhan
- Department of Medical PhysicsUniversity of Wisconsin‐MadisonMadisonWisconsinUSA
| | - Guang‐Hong Chen
- Department of Medical PhysicsUniversity of Wisconsin‐MadisonMadisonWisconsinUSA
- Department of RadiologyUniversity of Wisconsin‐MadisonMadisonWisconsinUSA
| | - Ke Li
- Department of Medical PhysicsUniversity of Wisconsin‐MadisonMadisonWisconsinUSA
- Department of Imaging PhysicsMD Anderson Cancer Center, University of TexasHoustonTexasUSA
- Department of Interventional RadiologyMD Anderson Cancer Center, University of TexasHoustonTexasUSA
| |
Collapse
|
2
|
Song J, He Y, Hu H, Li M, Li C, Yang B, Wei H. Anti-Scattering Perovskite Scintillator Arrays for High-Resolution Computed Tomography Imaging. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2025; 37:e2417248. [PMID: 39846284 DOI: 10.1002/adma.202417248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2024] [Revised: 01/13/2025] [Indexed: 01/24/2025]
Abstract
Computed tomography (CT) imaging has emerge as an effective medical diagnostic technique due to its rapid and 3D imaging capabilities, often employing indirect imaging methods through scintillator materials. Arraying scintillators that can confine light scattering to enable high-resolution CT imaging remains an area of ongoing exploration for emerging perovskite scintillators. Here an anti-scattering cesium lead bromide (CsPbBr3) scintillator array embedded within a polyurethane acrylate matrix for CT imaging using a cost-effective solution-processed method is reported. Due to the large refractive index contrast between the scintillator and matrix, photon propagation can be well confined within the CsPbBr3 scintillator array to significantly suppress the light scattering and enhance the light collection efficiency by nearly two times compared to the monolithic film. Furthermore, the scintillator array exhibits low-dosage and high-resolution CT imaging capability by reconstructing a 3D tooth image with a good spatial resolution of 20.1 lp cm-1 at a low effective dose of 0.22 mSv. This work highlights that the CsPbBr3 scintillator array is a highly promising candidate for CT imaging.
Collapse
Affiliation(s)
- Jinmei Song
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Yuhong He
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Haijing Hu
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Mingbian Li
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Chenglong Li
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
| | - Bai Yang
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
- Optical Functional Theranostics Joint Laboratory of Medicine and Chemistry, The First Hospital of Jilin University, Changchun, 130012, P. R. China
| | - Haotong Wei
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun, 130012, P. R. China
- Optical Functional Theranostics Joint Laboratory of Medicine and Chemistry, The First Hospital of Jilin University, Changchun, 130012, P. R. China
| |
Collapse
|
3
|
Gaztanaga J, Lopez-Mattei J. Modern CT detector technology and innovations in image reconstruction enhance cardiovascular CT. J Cardiovasc Comput Tomogr 2025; 19:72-73. [PMID: 39848820 DOI: 10.1016/j.jcct.2024.12.090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2024] [Accepted: 12/16/2024] [Indexed: 01/25/2025]
Affiliation(s)
- Juan Gaztanaga
- Department of Cardiac Imaging, Lee Health Heart Institute, Fort Myers, FL, United States
| | - Juan Lopez-Mattei
- Department of Cardiac Imaging, Lee Health Heart Institute, Fort Myers, FL, United States.
| |
Collapse
|
4
|
Pyakurel U, Sabounchi R, Eldib M, Bayat F, Phan H, Altunbas C. Evaluation of a compact cone beam CT concept with high image fidelity for point-of-care brain imaging. Sci Rep 2024; 14:28286. [PMID: 39550458 PMCID: PMC11569191 DOI: 10.1038/s41598-024-79874-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Accepted: 11/13/2024] [Indexed: 11/18/2024] Open
Abstract
Cone beam computed tomography (CBCT) has potential advantages for developing portable, cost-effective point-of-care CT systems for intracranial imaging, such as early stroke diagnosis, hemorrhage detection, and intraoperative navigation. However, large volume imaging with flat panel detector based CBCT significantly increases the scattered radiation fluence which reduces its image quality and utility. To address these issues, a compact CBCT concept with enhanced image quality was investigated for intracranial imaging. The new system features a novel antiscatter collimator and data correction method to address the challenges in imaging large volumes with CBCT. A benchtop CBCT prototype was constructed. Imaging studies with anthropomorphic phantoms showed that soft tissue visualization, Hounsfield Unit (HU) accuracy, contrast, and spatial resolution increased significantly with the proposed CBCT concept, and they were comparable to the values measured in the gold standard multidetector-row CT (MDCT) images. Contrast-to-noise ratio (CNR) in CBCT images was within 12-31% of the CNR in MDCT images. These findings indicate that a compact CBCT system integrated with effective scatter suppression techniques may have increased utility in the context of brain imaging, and the proposed approach may enable the development of point-of-care CT systems for head imaging based on flat panel detector based CBCT technology.
Collapse
Affiliation(s)
- Uttam Pyakurel
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA.
| | - Ryan Sabounchi
- Department of Bioengineering, University of Colorado Denver, 12705 East Montview Boulevard, Suite 100, Aurora, CO, 80045, USA
| | - Mohamed Eldib
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA
| | - Farhang Bayat
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA
| | - Hien Phan
- Department of Mechanical Engineering, University of Colorado Denver College of Engineering, Design and Computing, 1200 Larimer Street Suite 3034, Denver, CO, 80204, USA
| | - Cem Altunbas
- Department of Radiation Oncology, University of Colorado School of Medicine, 1665 Aurora Court, Suite 1032, Mail Stop F-706, Aurora, CO, 80045, USA.
| |
Collapse
|
5
|
Michail C, Liaparinos P, Kalyvas N, Kandarakis I, Fountos G, Valais I. Radiation Detectors and Sensors in Medical Imaging. SENSORS (BASEL, SWITZERLAND) 2024; 24:6251. [PMID: 39409289 PMCID: PMC11478476 DOI: 10.3390/s24196251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2024] [Revised: 09/23/2024] [Accepted: 09/25/2024] [Indexed: 10/20/2024]
Abstract
Medical imaging instrumentation design and construction is based on radiation sources and radiation detectors/sensors. This review focuses on the detectors and sensors of medical imaging systems. These systems are subdivided into various categories depending on their structure, the type of radiation they capture, how the radiation is measured, how the images are formed, and the medical goals they serve. Related to medical goals, detectors fall into two major areas: (i) anatomical imaging, which mainly concerns the techniques of diagnostic radiology, and (ii) functional-molecular imaging, which mainly concerns nuclear medicine. An important parameter in the evaluation of the detectors is the combination of the quality of the diagnostic result they offer and the burden of the patient with radiation dose. The latter has to be minimized; thus, the input signal (radiation photon flux) must be kept at low levels. For this reason, the detective quantum efficiency (DQE), expressing signal-to-noise ratio transfer through an imaging system, is of primary importance. In diagnostic radiology, image quality is better than in nuclear medicine; however, in most cases, the dose is higher. On the other hand, nuclear medicine focuses on the detection of functional findings and not on the accurate spatial determination of anatomical data. Detectors are integrated into projection or tomographic imaging systems and are based on the use of scintillators with optical sensors, photoconductors, or semiconductors. Analysis and modeling of such systems can be performed employing theoretical models developed in the framework of cascaded linear systems analysis (LCSA), as well as within the signal detection theory (SDT) and information theory.
Collapse
Affiliation(s)
| | | | | | - Ioannis Kandarakis
- Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, University of West Attica, Ag. Spyridonos, 12210 Athens, Greece; (C.M.); (P.L.); (N.K.); (G.F.); (I.V.)
| | | | | |
Collapse
|
6
|
Wang C, Zhang G, Liu Q, Kang S, Deng S, Chen J. Fabrication of ZnO Nanowire Cold Cathode Flat-Panel X-ray Source with a Reflective Anode. NANOMATERIALS (BASEL, SWITZERLAND) 2024; 14:1504. [PMID: 39330661 PMCID: PMC11435381 DOI: 10.3390/nano14181504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Revised: 09/12/2024] [Accepted: 09/14/2024] [Indexed: 09/28/2024]
Abstract
A novel reflective anode flat-panel X-ray source using ZnO nanowire cold cathode and a metal anode has been developed. Simulation analysis indicated that the reflective anode structure reduces electric field concentration compared to a transmission anode structure. The current-voltage characteristics, X-ray radiation dose rate, and stability of the fabricated device were thoroughly characterized. The device demonstrated a maximum emission current of 481.1 μA and a maximum radiation dose rate of 303 μGy/s at an anode voltage of 40 kV. The X-ray imaging of various objects was also conducted. Our findings are of significance for developing high-performance, robust flat-panel X-ray sources for diverse applications.
Collapse
Affiliation(s)
| | | | | | | | | | - Jun Chen
- State Key Laboratory of Optoelectronic Materials and Technologies, Guangdong Province Key Laboratory of Display Material and Technology, School of Electronics and Information Technology, Sun Yat-Sen University, Guangzhou 510275, China; (C.W.); (G.Z.); (Q.L.); (S.K.); (S.D.)
| |
Collapse
|
7
|
Toia GV, Mileto A, Borhani AA, Chen GH, Ren L, Uyeda JW, Marin D. Approaches, advantages, and challenges to photon counting detector and multi-energy CT. Abdom Radiol (NY) 2024; 49:3251-3260. [PMID: 38744702 DOI: 10.1007/s00261-024-04357-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 04/21/2024] [Accepted: 04/21/2024] [Indexed: 05/16/2024]
Abstract
Photon counting detector CT (PCD-CT) is the newest major development in CT technology and has been commercially available since 2021. It offers major technological advantages over current standard-of-care energy integrating detector CT (EID-CT) including improved spatial resolution, improved iodine contrast to noise ratio, multi-energy imaging, and reduced noise. This article serves as a foundational basis to the technical approaches and concepts of PCD-CT technology with primary emphasis on detector technology in direct comparison to EID-CT. The article also addresses current technological challenges to PCD-CT with particular attention to cross talk and its causes (e.g., Compton scattering, fluorescence, charge sharing, K-escape) as well as pile-up.
Collapse
Affiliation(s)
- Giuseppe V Toia
- Departments of Radiology and Medical Physics, University of Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI, 53792, USA.
| | - Achille Mileto
- Department of Radiology, University of Washington, Seattle, WA, USA
| | - Amir A Borhani
- Department of Radiology, Northwestern University, Chicago, IL, USA
| | - Guang-Hong Chen
- Departments of Radiology and Medical Physics, University of Wisconsin School of Medicine and Public Health, 600 Highland Ave, Madison, WI, 53792, USA
| | - Liqiang Ren
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX, USA
| | - Jennifer W Uyeda
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Daniele Marin
- Department of Radiology, Duke University Health System, Durham, NC, USA
| |
Collapse
|
8
|
Zhu Q, Wei S, Wang Z, Xu H, Zhou B, Qu H, Nie M, Guo N, Wang W, Yang B, Qiu J. Feasibility of dose calculation for treatment plans using electron density maps from a novel dual-layer detector spectral CT simulator. Radiat Oncol 2024; 19:93. [PMID: 39049106 PMCID: PMC11267670 DOI: 10.1186/s13014-024-02479-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 06/21/2024] [Indexed: 07/27/2024] Open
Abstract
BACKGROUND Conventional single-energy CT can only provide a raw estimation of electron density (ED) for dose calculation by developing a calibration curve that simply maps the HU values to ED values through their correlations. Spectral CT, also known as dual-energy CT (DECT) or multi-energy CT, can generate a series of quantitative maps, such as ED maps. Using spectral CT for radiotherapy simulations can directly acquire ED information without developing specific calibration curves. The purpose of this study is to assess the feasibility of utilizing electron density (ED) maps generated by a novel dual-layer detector spectral CT simulator for dose calculation in radiotherapy treatment plans. METHODS 30 patients from head&neck, chest, and pelvic treatment sites were selected retrospectively, and all of them underwent spectral CT simulation. Treatment plans based on conventional CT images were transplanted to ED maps with the same structure set, including planning target volume (PTV) and organs at risk (OARs), and the dose distributions were then recalculated. The differences in dose and volume histogram (DVH) parameters of the PTV and OARs between the two types of plans were analyzed and compared. Besides, gamma analysis between these plans was performed by using MEPHYSTO Navigator software. RESULTS In terms of PTV, the homogeneity index (HI), gradient index (GI), D2%, D98%, and Dmean showed no significant difference between conventional plans and ED plans. For OARs, statistically significant differences were observed in parotids D50%, brainstem in head&neck plans, spinal cord in chest plans and rectum D50% in pelvic plans, whereas the variance remained minor. For the rest, the DVH parameters exhibited no significant difference between conventional plans and ED plans. All of the mean gamma passing rates (GPRs) of gamma analysis were higher than 90%. CONCLUSION Compared to conventional treatment plans relying on CT images, plans utilizing ED maps demonstrated similar dosimetric quality. However, the latter approach enables direct utilization in dose calculation without the requirements of establishing and selecting a specific Hounsfield unit (HU) to ED calibration curve, providing an advantage in clinical applications.
Collapse
Affiliation(s)
- Qizhen Zhu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Shuoyang Wei
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zhiqun Wang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Haoran Xu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Bing Zhou
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Huiying Qu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | | | - Ning Guo
- Philips Clinical Science, Beijing, China
| | | | - Bo Yang
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| | - Jie Qiu
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| |
Collapse
|
9
|
Fix Martinez M, Klein L, Maier J, Rotkopf LT, Schlemmer HP, Schönberg SO, Kachelrieß M, Sawall S. Potential radiation dose reduction in clinical photon-counting CT by the small pixel effect: ultra-high resolution (UHR) acquisitions reconstructed to standard resolution. Eur Radiol 2024; 34:4484-4491. [PMID: 38133673 PMCID: PMC11213748 DOI: 10.1007/s00330-023-10499-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/13/2023] [Accepted: 11/08/2023] [Indexed: 12/23/2023]
Abstract
OBJECTIVE To assess the potential dose reduction achievable with clinical photon-counting CT (PCCT) in ultra-high resolution (UHR) mode compared to acquisitions using the standard resolution detector mode (Std). MATERIALS AND METHODS With smaller detector pixels, PCCT achieves far higher spatial resolution than energy-integrating (EI) CT systems. The reconstruction of UHR acquisitions to the lower spatial resolution of conventional systems results in an image noise and radiation dose reduction. We quantify this small pixel effect in measurements of semi-anthropomorphic abdominal phantoms of different sizes as well as in a porcine knuckle in the first clinical PCCT system by using the UHR mode (0.2 mm pixel size at isocenter) in comparison to the standard resolution mode (0.4 mm). At different slice thicknesses (0.4 up to 4 mm) and dose levels between 4 and 12 mGy, reconstructions using filtered backprojection were performed to the same target spatial resolution, i.e., same modulation transfer function, using both detector modes. Image noise and the resulting potential dose reduction was quantified as a figure of merit. RESULTS Images acquired using the UHR mode yield lower noise in comparison to acquisitions using standard pixels at the same resolution and noise level. This holds for sharper convolution kernels at the spatial resolution limit of the standard mode, e.g., up to a factor 3.2 in noise reduction and a resulting potential dose reduction of up to almost 90%. CONCLUSION Using sharper convolution kernels, UHR acquisitions allow for a significant dose reduction compared to acquisitions using the standard detector mode. CLINICAL RELEVANCE Acquisitions should always be performed using the ultra-high resolution detector mode, if possible, to benefit from the intrinsic noise and dose reduction. KEY POINTS • Ionizing radiation used in computed tomography examinations is a concern to public health. • The ultra-high resolution of novel photon-counting systems can be invested towards a noise and dose reduction if only a spatial resolution below the resolution limit of the detector is desired. • Acquisitions should always be performed in ultra-high resolution mode, if possible, to benefit from an intrinsic dose reduction.
Collapse
Affiliation(s)
- Markel Fix Martinez
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Laura Klein
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Joscha Maier
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Lukas Thomas Rotkopf
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Heinz-Peter Schlemmer
- Division of Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Stefan Oswald Schönberg
- Department of Clinical Radiology and Nuclear Medicine, University Hospital Mannheim, Theodor-Kurz-Ufer 1-3, 68167, Mannheim, Germany
| | - Marc Kachelrieß
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
- Medical Faculty, Heidelberg University, Im Neuenheimer Feld 672, 69120, Heidelberg, Germany
| | - Stefan Sawall
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
- Medical Faculty, Heidelberg University, Im Neuenheimer Feld 672, 69120, Heidelberg, Germany.
| |
Collapse
|
10
|
Yu H, Liu C, Thies M, Wagner F, Wang A, Zhang G, Huang Y, Liu F, Maier A. Reducing penumbral blur in computed tomography by learning the inverse finite focal spot model. OPTICS EXPRESS 2024; 32:23674-23686. [PMID: 39538824 DOI: 10.1364/oe.527304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Accepted: 06/04/2024] [Indexed: 11/16/2024]
Abstract
Penumbral blur is one of the major limitations of the high spatial resolution micro-CT, due to a nonideal large focal spot. Penumbral blur hinders the ability to resolve small features that may only be a few pixels in size. Reducing the focal spot size by decreasing the x-ray tube power is a straightforward solution, but it leads to prolonged scan durations. In this paper, we propose to mitigate the penumbral blur by learning the inverse finite focal spot model. First, we derived the finite focal spot model that builds a relationship from the ideal point source projection to the finite focal spot projection. Based on the derived model, we numerically compute a paired projection dataset. Second, we utilized two neural networks-U-net, and convolution modulation-based U-net (CMU-net) -to learn the inverse finite focal spot model. The goal is to estimate the ideal point source projection from the actual finite focal spot projection. CMU-net, which introduces convolution modulation blocks into the contracting path of the U-net, is proposed to boost the robustness of the U-net. Finally, the standard filtered back-projection (FBP) is employed for reconstruction using the estimated ideal point projection. The experiments show that both U-net and CMU-net can effectively reduce the penumbral blur, whereas CMU-net demonstrates better performance on the real data. Experiments on real measured data demonstrate that CMU-net is more robust than U-net and can effectively resolve fine details. This method has great potential in improving the efficiency of micro-CT acquisition. It allows increasing the tube power since our method can computationally compensate for the blur caused by an increased focal spot size.
Collapse
|
11
|
Kazimirov D, Polevoy D, Ingacheva A, Chukalina M, Nikolaev D. Adaptive automated sinogram normalization for ring artifacts suppression in CT. OPTICS EXPRESS 2024; 32:17606-17643. [PMID: 38858941 DOI: 10.1364/oe.522941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 04/13/2024] [Indexed: 06/12/2024]
Abstract
Ring artifacts pose a major barrier to obtaining precise reconstruction in computed tomography (CT). The presence of ring artifacts complicates the use of automatic means of processing CT reconstruction results, such as segmentation, correction of geometric shapes, alignment of reconstructed volumes. Although there are numerous efficient methods for suppressing ring artifacts, many of them appear to be manual. Along with this, a large proportion of the automatic methods cope unsatisfactorily with the target task while requiring computational capacity. The current work introduces a projection data preprocessing method for suppressing ring artifacts that constitutes a compromise among the outlined aspects - automaticity, high efficiency and computational speed. Derived as the automation of the classical sinogram normalization method, the proposed method specific advantages consist in adaptability in relation to the filtered sinograms and the edge-preservation property proven within the experiments on both synthetic and real CT data. Concerning the challenging open-access data, the method has performed superior quality comparable to that of the advanced methods: it has demonstrated 70.4% ring artifacts suppression percentage (RASP) quality metric. In application to our real laboratory CT data, the proposed method allowed us to gain significant refinement of the reconstruction quality which has not been surpassed by a range of compared manual ring artifacts suppression methods.
Collapse
|
12
|
Dillenseger JP, Gillet R, Louis M, Bach J, Sieffert C, Meylheuc L, Palpacuer C, Bierry G, Garnon J, Blum A. Quantitative and qualitative evaluation of three MSCT for high resolution bone imaging. Eur J Radiol 2024; 173:111394. [PMID: 38428256 DOI: 10.1016/j.ejrad.2024.111394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 11/09/2023] [Accepted: 02/23/2024] [Indexed: 03/03/2024]
Abstract
INTRODUCTION Strategies for achieving high resolution varies between manufacturers. In CT, the helical mode with narrow collimation has long been considered as the gold standard for high-resolution imaging. More recently, incremental modes with small dexels and focal spot, have been developed but have not been compared with helical acquisitions under optimal conditions. The aim of this work is to compare the high-resolution acquisition strategies currently proposed by recent MSCT. METHODS Three CT systems were compared. A phantom was used to evaluate geometric accuracy, uniformity, scan slice geometry, and spatial resolution. Human dry bones were used to test different protocols on real bone architecture. A blind visual analysis was conducted by trained CT users for classifying the different acquisitions (p-values). RESULTS All systems give satisfactory results in terms of geometric accuracy and uniformity. The in-plane MTF at 5% were respectively 13.4, 15.9 and 18.1 lp/cm. Dry-bones evaluation confirms that acquisition#3 is considered as the best. CONCLUSIONS The incremental acquisition coupled with à small focal spot, and a high-sampling detector, overpasses the reference of low-pitch helical acquisitions for high-resolution imaging. Cortical bone, bony vessels, and tumoral matrix analysis are the very next challenges that will have to be managed to improve normal and pathologic bone imaging thanks to the availability UHR-CT systems.
Collapse
Affiliation(s)
- Jean-Philippe Dillenseger
- ICube - UMR 7357, CNRS, Université de Strasbourg, Strasbourg, France; Pole d'imagerie médicale, Hôpitaux universitaire de Strasbourg, Strasbourg, France.
| | - Romain Gillet
- Service D'imagerie Guilloz, CHRU Nancy, Nancy, France; IADI - U1254, Inserm, Université de Lorraine, Nancy, France
| | | | - Justin Bach
- Pole d'imagerie médicale, Hôpitaux universitaire de Strasbourg, Strasbourg, France.
| | - Cléa Sieffert
- ICube - UMR 7357, CNRS, Université de Strasbourg, Strasbourg, France.
| | - Laurence Meylheuc
- ICube - UMR 7357, CNRS, Université de Strasbourg, Strasbourg, France.
| | - Clément Palpacuer
- Clinical research department, Groupe Hospitalier Mulhouse et Sud Alsace, Mulhouse, France.
| | - Guillaume Bierry
- ICube - UMR 7357, CNRS, Université de Strasbourg, Strasbourg, France; Pole d'imagerie médicale, Hôpitaux universitaire de Strasbourg, Strasbourg, France.
| | - Julien Garnon
- ICube - UMR 7357, CNRS, Université de Strasbourg, Strasbourg, France; Pole d'imagerie médicale, Hôpitaux universitaire de Strasbourg, Strasbourg, France.
| | - Alain Blum
- Service D'imagerie Guilloz, CHRU Nancy, Nancy, France; IADI - U1254, Inserm, Université de Lorraine, Nancy, France.
| |
Collapse
|
13
|
Van Ballaer V, Dubbeldam A, Muscogiuri E, Cockmartin L, Bosmans H, Coudyzer W, Coolen J, de Wever W. Impact of ultra-high-resolution imaging of the lungs on perceived diagnostic image quality using photon-counting CT. Eur Radiol 2024; 34:1895-1904. [PMID: 37650968 DOI: 10.1007/s00330-023-10174-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 07/06/2023] [Accepted: 07/13/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVES To compare clinical image quality and perceived impact on diagnostic interpretation of chest CT findings between ultra-high-resolution photon-counting CT (UHR-PCCT) and conventional high-resolution energy-integrating-detector CT (HR-EIDCT) using visual grading analysis (VGA) scores. MATERIALS AND METHODS Fifty patients who underwent a UHR-PCCT (matrix 512 × 512, 768 × 768, or 1024 × 1024; FOV average 275 × 376 mm, 120 × 0.2 mm; focal spot size 0.6 × 0.7 mm) between November 2021 and February 2022 and with a previous HR-EIDCT within the last 14 months were included. Four readers evaluated central and peripheral airways, lung vasculature, nodules, ground glass opacities, inter- and intralobular lines, emphysema, fissures, bullae/cysts, and air trapping on PCCT (0.4 mm) and conventional EIDCT (1 mm) via side-by-side reference scoring using a 5-point diagnostic quality score. The median VGA scores were compared and tested using one-sample Wilcoxon signed rank tests with hypothesized median values of 0 (same visibility) and 2 (better visibility on PCCT with impact on diagnostic interpretation) at a 2.5% significance level. RESULTS Almost all lung structures had significantly better visibility on PCCT compared to EIDCT (p < 0.025; exception for ground glass nodules (N = 2/50 patients, p = 0.157)), with the highest scores seen for peripheral airways, micronodules, inter- and intralobular lines, and centrilobular emphysema (mean VGA > 1). Although better visibility, a perceived difference in diagnostic interpretation could not be demonstrated, since the median VGA was significantly different from 2. CONCLUSION UHR-PCCT showed superior visibility compared to HR-EIDCT for central and peripheral airways, lung vasculature, fissures, ground glass opacities, macro- and micronodules, inter- and intralobular lines, paraseptal and centrilobular emphysema, bullae/cysts, and air trapping. CLINICAL RELEVANCE STATEMENT UHR-PCCT has emerged as a promising technique for thoracic imaging, offering improved spatial resolution and lower radiation dose. Implementing PCCT into daily practice may allow better visibility of multiple lung structures and optimization of scan protocols for specific pathology. KEY POINTS • The aim of this study was to verify if the higher spatial resolution of UHR-PCCT would improve the visibility and detection of certain lung structures and abnormalities. • UHR-PCCT was judged to have superior clinical image quality compared to conventional HR-EIDCT in the evaluation of the lungs. UHR-PCCT showed better visibility for almost all tested lung structures (except for ground glass nodules). • Despite superior image quality, the readers perceived no significant impact on the diagnostic interpretation of the studied lung structures and abnormalities.
Collapse
Affiliation(s)
- Valerie Van Ballaer
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium.
| | - Adriana Dubbeldam
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| | - Emanuele Muscogiuri
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| | - Lesley Cockmartin
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| | - Hilde Bosmans
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| | - Walter Coudyzer
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| | - Johan Coolen
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| | - Walter de Wever
- Department of Radiology, University Hospitals Leuven, Herestraat 49 3000, Louvain, Belgium
| |
Collapse
|
14
|
Skrodzki D, Molinaro M, Brown R, Moitra P, Pan D. Synthesis and Bioapplication of Emerging Nanomaterials of Hafnium. ACS NANO 2024; 18:1289-1324. [PMID: 38166377 DOI: 10.1021/acsnano.3c08917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2024]
Abstract
A significant amount of progress in nanotechnology has been made due to the development of engineered nanoparticles. The use of metallic nanoparticles for various biomedical applications has been extensively investigated. Biomedical research is highly focused on them because of their inert nature, nanoscale structure, and similar size to many biological molecules. The intrinsic characteristics of these particles, including electronic, optical, physicochemical, and surface plasmon resonance, that can be altered by altering their size, shape, environment, aspect ratio, ease of synthesis, and functionalization properties, have led to numerous biomedical applications. Targeted drug delivery, sensing, photothermal and photodynamic therapy, and imaging are some of these. The promising clinical results of NBTXR3, a high-Z radiosensitizing nanomaterial derived from hafnium, have demonstrated translational potential of this metal. This radiosensitization approach leverages the dependence of energy attenuation on atomic number to enhance energy-matter interactions conducive to radiation therapy. High-Z nanoparticle localization in tumor issue differentially increases the effect of ionizing radiation on cancer cells versus nearby healthy ones and mitigates adverse effects by reducing the overall radiation burden. This principle enables material multifunctionality as contrast agents in X-ray-based imaging. The physiochemical properties of hafnium (Z = 72) are particularly advantageous for these applications. A well-placed K-edge absorption energy and high mass attenuation coefficient compared to elements in human tissue across clinical energy ranges leads to significant attenuation. Chemical reactivity allows for variety in nanoparticle synthesis, composition, and functionalization. Nanoparticles such as hafnium oxide exhibit excellent biocompatibility due to physiochemical inertness prior to incidence with ionizing radiation. Additionally, the optical and electronic properties are applicable in biosensing, optical component coatings, and semiconductors. The wide interest has prompted extensive research in design and synthesis to facilitate property fine-tuning. This review summarizes synthetic methods for hafnium-based nanomaterials and applications in therapy, imaging, and biosensing with a mechanistic focus. A discussion and future perspective section highlights clinical progress and elaborates on current challenges. By focusing on factors impacting applicational effectiveness and examining limitations this review aims to support researchers and expedite clinical translation of future hafnium-based nanomedicine.
Collapse
Affiliation(s)
- David Skrodzki
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Matthew Molinaro
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Richard Brown
- Department of Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Parikshit Moitra
- Department of Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Dipanjan Pan
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Department of Nuclear Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Huck Institutes of the Life Sciences, 101 Huck Life Sciences Building, University Park, Pennsylvania 16802, United States
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
15
|
Zhan X, Zhang R, Niu X, Hein I, Budden B, Wu S, Markov N, Clarke C, Qiang Y, Taguchi H, Nomura K, Muramatsu Y, Yu Z, Kobayashi T, Thompson R, Miyazaki H, Nakai H. Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies. Phys Med Biol 2023; 68:175007. [PMID: 37506710 DOI: 10.1088/1361-6560/acebb3] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 07/28/2023] [Indexed: 07/30/2023]
Abstract
Objective. Photon counting CT (PCCT) has been a research focus in the last two decades. Recent studies and advancements have demonstrated that systems using semiconductor-based photon counting detectors (PCDs) have the potential to provide better contrast, noise and spatial resolution performance compared to conventional scintillator-based systems. With multi-energy threshold detection, PCD can simultaneously provide the photon energy measurement and enable material decomposition for spectral imaging. In this work, we report a performance evaluation of our first CdZnTe-based prototype full-size PCCT system through various phantom imaging studies.Approach.This prototype system supports a 500 mm scan field-of-view and 10 mmz-coverage at isocenter. Phantom scans were acquired using 120 kVp from 50 to 400 mAs to assess the imaging performance on: CT number accuracy, uniformity, noise, spatial resolution, material differentiation and quantification.Main results.Both qualitative and quantitative evaluations show that PCCT, under the tested conditions, has superior imaging performance with lower noise and improved spatial resolution compared to conventional energy integrating detector (EID)-CT. Using projection domain material decomposition approach with multiple energy bin measurements, PCCT virtual monoenergetic images have lower noise, and good accuracy in quantifying iodine and calcium concentrations. These results lead to increased contrast-to-noise ratio (CNR) for both high and low contrast study objects compared to EID-CT at matched dose and spatial resolution. PCCT can also generate super-high resolution images using much smaller detector pixel size than EID-CT and greatly improve image spatial resolution.Significance.Improved spatial resolution and quantification accuracy with reduced image noise of the PCCT images can potentially lead to better diagnosis at reduced radiation dose compared to conventional EID-CT. Increased CNR achieved by PCCT suggests potential reduction in iodine contrast media load, resulting in better patient safety and reduced cost.
Collapse
Affiliation(s)
- Xiaohui Zhan
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Ruoqiao Zhang
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Xiaofeng Niu
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Ilmar Hein
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Brent Budden
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Shuoxing Wu
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Nicolay Markov
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Cameron Clarke
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Yi Qiang
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | - Hiroki Taguchi
- Canon Medical System Corporation, Otawara, Tochigi, Japan
| | - Keiichi Nomura
- National Cancer Centre Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Japan
| | | | - Zhou Yu
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | | | - Richard Thompson
- Canon Medical Research USA, Inc., 706 Deerpath Drive, Vernon Hills, IL 60061, United States of America
| | | | - Hiroaki Nakai
- Canon Medical System Corporation, Otawara, Tochigi, Japan
| |
Collapse
|
16
|
Stein T, Rau A, Russe MF, Arnold P, Faby S, Ulzheimer S, Weis M, Froelich MF, Overhoff D, Horger M, Hagen F, Bongers M, Nikolaou K, Schönberg SO, Bamberg F, Weiß J. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. ROFO-FORTSCHR RONTG 2023; 195:691-698. [PMID: 36863367 DOI: 10.1055/a-2018-3396] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
BACKGROUND Photon-counting computed tomography (PCCT) is a promising new technology with the potential to fundamentally change today's workflows in the daily routine and to provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD The content of this review is based on an unrestricted literature search on PubMed and Google Scholar using the search terms "Photon-Counting CT", "Photon-Counting detector", "spectral CT", "Computed Tomography" as well as on the authors' experience. RESULTS The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCCT allows counting of every single photon at the detector level. Based on the identified literature, PCCT phantom measurements and initial clinical studies have demonstrated that the new technology allows improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION For clinical practice, the potential benefits include fewer beam hardening artifacts, radiation dose reduction, and the use of new contrast agents. In this review, we will discuss basic technical principles and potential clinical benefits and demonstrate first clinical use cases. KEY POINTS · Photon-counting computed tomography (PCCT) has been implemented in the clinical routine. · Compared to energy-integrating detector CT, PCCT allows the reduction of electronic image noise. · PCCT provides increased spatial resolution and a higher contrast-to-noise ratio. · The novel detector technology allows the quantification of spectral information. CITATION FORMAT · Stein T, Rau A, Russe MF et al. Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience. Fortschr Röntgenstr 2023; 195: 691 - 698.
Collapse
Affiliation(s)
- Thomas Stein
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Alexander Rau
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Maximilian Frederik Russe
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Philipp Arnold
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Sebastian Faby
- Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany
| | - Stefan Ulzheimer
- Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany
| | - Meike Weis
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Matthias F Froelich
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Daniel Overhoff
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Marius Horger
- Department of Radiology, University Hospitals Tübingen, Germany
| | - Florian Hagen
- Department of Radiology, University Hospitals Tübingen, Germany
| | - Malte Bongers
- Department of Radiology, University Hospitals Tübingen, Germany
| | | | - Stefan O Schönberg
- Department of Radiology and Nuclear Medicine, University Medical Centre Mannheim, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| | - Jakob Weiß
- Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Germany
| |
Collapse
|
17
|
Tessitore G, Mandl GA, Maurizio SL, Kaur M, Capobianco JA. The role of lanthanide luminescence in advancing technology. RSC Adv 2023; 13:17787-17811. [PMID: 37323462 PMCID: PMC10263103 DOI: 10.1039/d3ra00991b] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 05/30/2023] [Indexed: 06/17/2023] Open
Abstract
Our society is indebted to the numerous inventors and scientists who helped bring about the incredible technological advances in modern society that we all take for granted. The importance of knowing the history of these inventions is often underestimated, although our reliance on technology is escalating. Lanthanide luminescence has paved the way for many of these inventions, from lighting and displays to medical advancements and telecommunications. Given the significant role of these materials in our daily lives, knowingly or not, their past and present applications are reviewed. A majority of the discussion is devoted to pointing out the benefits of using lanthanides over other luminescent species. We aimed to give a short outlook outlines promising directions for the development of the considered field. This review aims to provide the reader enough content to further appreciate the benefits that these technologies have brought into our lives, with the perspective of travelling among the past and latest advances in lanthanide research, aiming for an even brighter future.
Collapse
Affiliation(s)
- Gabriella Tessitore
- Concordia University, Department of Chemistry and Biochemistry & Center for NanoScience Research 7141 Rue Sherbrooke Ouest Montreal QC Canada
- Department of Chemistry, Université Laval 1045 Av. de la Médecine Québec QC G1V 0A6 Canada
| | - Gabrielle A Mandl
- Concordia University, Department of Chemistry and Biochemistry & Center for NanoScience Research 7141 Rue Sherbrooke Ouest Montreal QC Canada
| | - Steven L Maurizio
- Concordia University, Department of Chemistry and Biochemistry & Center for NanoScience Research 7141 Rue Sherbrooke Ouest Montreal QC Canada
| | - Mannu Kaur
- Concordia University, Department of Chemistry and Biochemistry & Center for NanoScience Research 7141 Rue Sherbrooke Ouest Montreal QC Canada
| | - John A Capobianco
- Concordia University, Department of Chemistry and Biochemistry & Center for NanoScience Research 7141 Rue Sherbrooke Ouest Montreal QC Canada
| |
Collapse
|
18
|
Agostini A, Borgheresi A, Mariotti F, Ottaviani L, Carotti M, Valenti M, Giovagnoni A. New Frontiers in Oncological Imaging With Computed Tomography: From Morphology to Function. Semin Ultrasound CT MR 2023; 44:214-227. [PMID: 37245886 DOI: 10.1053/j.sult.2023.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
Abstract
The latest evolutions in Computed Tomography (CT) technology have several applications in oncological imaging. The innovations in hardware and software allow for the optimization of the oncological protocol. Low-kV acquisitions are possible thanks to the new powerful tubes. Iterative reconstruction algorithms and artificial intelligence are helpful for the management of image noise during image reconstruction. Functional information is provided by spectral CT (dual-energy and photon counting CT) and perfusion CT.
Collapse
Affiliation(s)
- Andrea Agostini
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy.
| | - Alessandra Borgheresi
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Francesco Mariotti
- Department of Radiological Sciences, Division of Medical Physics, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Letizia Ottaviani
- Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Marina Carotti
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Marco Valenti
- Department of Radiological Sciences, Division of Medical Physics, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| | - Andrea Giovagnoni
- Department of Clinical, Special and Dental Sciences. University Politecnica delle Marche, Ancona, Italy; Department of Radiological Sciences, Division of Clinical Radiology, University Hospital "Azienda Ospedaliero Universitaria delle Marche", Ancona, Italy
| |
Collapse
|
19
|
Lyu Q, Neph R, Sheng K. Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing. Nat Biomed Eng 2023; 7:323-334. [PMID: 36280738 PMCID: PMC10038801 DOI: 10.1038/s41551-022-00953-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 09/14/2022] [Indexed: 01/07/2023]
Abstract
Measuring the radiation dose reaching a patient's body is difficult. Here we report a technique for the tomographic reconstruction of the location of photon pairs originating from the annihilation of positron-electron pairs produced by high-energy X-rays travelling through tissue. We used Monte Carlo simulations on pre-recorded data from tissue-mimicking phantoms and from a patient with a brain tumour to show the feasibility of this imaging modality, which we named 'pair-production tomography', for the monitoring of radiotherapy dosing. We simulated three image-reconstruction methods, one applicable to a pencil X-ray beam scanning through a region of interest, and two applicable to the excitation of tissue volumes via broad beams (with temporal resolution sufficient to identify coincident photon pairs via filtered back projection, or with higher temporal resolution sufficient for the estimation of a photon's time-of-flight). In addition to the monitoring of radiotherapy dosing, we show that image contrast resulting from pair-production tomography is highly proportional to the material's atomic number. The technique may thus also allow for element mapping and for soft-tissue differentiation.
Collapse
Affiliation(s)
- Qihui Lyu
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, USA
| | - Ryan Neph
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, USA
| | - Ke Sheng
- Department of Radiation Oncology, University of California Los Angeles, Los Angeles, CA, USA.
| |
Collapse
|
20
|
Sartoretti T, Wildberger JE, Flohr T, Alkadhi H. Photon-counting detector CT: early clinical experience review. Br J Radiol 2023:20220544. [PMID: 36744809 DOI: 10.1259/bjr.20220544] [Citation(s) in RCA: 46] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Since its development in the 1970s, X-ray CT has emerged as a landmark diagnostic imaging modality of modern medicine. Technological advances have been crucial to the success of CT imaging, as they have increasingly enabled improvements in image quality and diagnostic value at increasing radiation dose efficiency. With recent advances in engineering and physics, a novel technology has emerged with the potential to surpass several shortcomings and limitations of current CT systems. Photon-counting detector (PCD)-CT might substantially improve and expand the applicability of CT imaging by offering intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise and improved image contrast. In this review we sought to summarize the first clinical experience of PCD-CT. We focused on most recent prototype and first clinically approved PCD-CT systems thereby reviewing initial publications and presenting corresponding clinical cases.
Collapse
Affiliation(s)
- Thomas Sartoretti
- Diagnostic and Interventional Radiology, University Hospital Zürich, University of Zürich, Zürich, Switzerland.,Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Joachim E Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, The Netherlands.,Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands
| | - Thomas Flohr
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zürich, University of Zürich, Zürich, Switzerland
| |
Collapse
|
21
|
Mahani H, Taheri A, Askari M. Detection performance of pixelated lutetium-yttrium oxyorthosilicate (LYSO) scintillators for high-resolution photon-counting CT imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:023308. [PMID: 36859068 DOI: 10.1063/5.0125952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Accepted: 02/02/2023] [Indexed: 06/18/2023]
Abstract
High-resolution photon-counting detector (PCD) computed tomography (CT) imaging is increasingly used for several applications. Recent technological advances in CT instrumentation have introduced various types of radiation detectors. Therefore, this work aims at evaluating the lutetium-yttrium oxyorthosilicate (LYSO) scintillator for use in PCD CT from a detector point of view. To do so, a mini-CT prototype was designed and constructed based on the pixelated LYSO blocks. The detector comprises four 10 × 10 linearly arranged LYSO blocks coupled with four position-sensitive photomultiplier tubes. The prototype utilizes a point gamma-ray source along with a cone-beam collimator. An in-home MATLAB-based data processing software package was also developed for storing the list-mode data, event positioning, and energy windowing. A set of experiments were conducted to assess the performance of the constructed energy-resolved LYSO:Ce detector for mini-CT imaging. The results show good crystal identification for all blocks with a maximum peak-to-valley ratio of 3.48. In addition, the findings confirm that the developed detector is position-sensitive. The 20% energy window provides an optimal performance by simultaneously providing good crystal identification and a scatter removal factor of 0.71. A 96% uniformity was also observed when the detector was irradiated with a uniform flood. The spatial resolution of the mini-CT prototype in the x- and y-directions was calculated to be 0.9 and 0.93 mm, respectively, corrected for a magnification factor of 2.5. It is concluded that the pixelated LYSO crystal is a promising alternative to the current detectors and would be the scintillator of choice for high-resolution PCD CT imaging tasks.
Collapse
Affiliation(s)
- Hojjat Mahani
- Radiation Applications Research School, Nuclear Science and Technology Research Institute, P.O. Box 14395-836, Tehran, Iran
| | - Ali Taheri
- Radiation Applications Research School, Nuclear Science and Technology Research Institute, P.O. Box 14395-836, Tehran, Iran
| | - Mojtaba Askari
- Radiation Applications Research School, Nuclear Science and Technology Research Institute, P.O. Box 14395-836, Tehran, Iran
| |
Collapse
|
22
|
Langguth P, Aludin S, Horr A, Campbell GM, Lebenatus A, Salehi Ravesh M, Schunk D, Austein F, Larsen N, Syrek H, Both M, Jansen O, Sedaghat S. Iodine uptake of adrenal glands: A novel and reliable spectral dual-layer computed tomographic-derived biomarker for acute septic shock. Eur J Radiol 2022; 156:110492. [PMID: 36108480 DOI: 10.1016/j.ejrad.2022.110492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/09/2022] [Accepted: 08/15/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Septic shock is a potentially fatal condition. This study aims to assess whether iodine uptake and iodine density of abdominal organs on dual-layer spectral detector computed tomography (SDCT) could serve as a new imaging biomarker for patients in septic shock. METHODS Here, 95 patients who received contrast-enhanced abdominal CT examinations were included and separated into two groups: group A - septic shock; group B - no shock condition. Preselected abdominal (right and left adrenal gland, right and left kidney, infrarenal inferior vena cava (IVC), pancreas, spleen, and liver) localizations were independently evaluated by two radiologists, who measured iodine concentrations (mg/ml) and Hounsfield units (HU). RESULTS In all, 1520 measurements of iodine concentrations in mg/ml and HU were performed, with 27 patients in group A and 68 in group B. Iodine concentrations in mg/ml and HU correlated significantly in all organs measured. The corresponding correlation coefficient (r) ranged from 0.809 (pancreas) to 0.963 (right kidney). Inter-rater reliability (IRR) was very good for mg/ml (κ = 0.8; p < 0.01) and good for HU (κ = 0.773; p < 0.01) measurements. The mean iodine concentration and HU of the adrenal glands in septic and nonseptic patients was 4.88 ± 1.16 mg/ml/153 ± 36 HU and 2.67 ± 1.07 mg/ml/112 ± 41 HU, respectively. Iodine concentrations in the adrenal glands were significantly higher in group A than in group B patients (p < 0.01). The other organs remained unaffected and no significant difference was observed between patients in group A and B. Patients in group A presented significantly more often with an iodine uptake of >3.5 mg/ml of one adrenal gland (sensitivity = 0.926, specificity = 0.849, AUC = 0.951) or/and a combined concentration of >7 mg/ml of both adrenal glands (sensitivity = 0.889, specificity = 0.836, AUC = 0.928). CONCLUSION SDCT-derived iodine concentration of the adrenal glands could serve as a novel imaging biomarker for patients in acute septic shock. Our data suggest that an iodine uptake of >3.5 mg/ml of at least one adrenal gland or a combined iodine uptake of >7 mg/ml in both adrenal glands identifies patients in this condition.
Collapse
Affiliation(s)
- P Langguth
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany.
| | - S Aludin
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - A Horr
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | | | - A Lebenatus
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - M Salehi Ravesh
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - D Schunk
- Department for Interdisciplinary Emergency, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - F Austein
- Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - N Larsen
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - H Syrek
- Mediri GmbH, Heidelberg, Germany
| | - M Both
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - O Jansen
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany
| | - S Sedaghat
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Campus Kiel, Germany; Department of Radiology, University of California San Diego, San Diego, CA, United States
| |
Collapse
|
23
|
Luminescence Efficiency of Cerium Bromide Single Crystal under X-ray Radiation. CRYSTALS 2022. [DOI: 10.3390/cryst12070909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
A rare-earth trihalide scintillator, CeBr3, in 1 cm edge cubic monocrystal form, is examined with regard to its principal luminescence and scintillation properties, as a candidate for radiation imaging applications. This relatively new material exhibits attractive properties, including short decay time, negligible afterglow, high stopping power and emission spectrum compatible with several commercial optical sensors. In a setting typical for X-ray radiology (medical X-ray tube, spectra in the range 50–140 kVp, human chest equivalent filtering), the crystal’s light energy flux, absolute efficiency (AE) and X-ray luminescence efficiency (XLE) were determined. Light energy flux results are superior in comparison to other four materials broadly used in modern medical imaging (slope of the linear no-threshold fit was 29.5). The AE is superior from 90 kVp onwards and reaches a value of 29.5 EU at 140 kVp. The same is true for the XLE that, following a flat response, reaches 9 × 10−3 at 90 kVp. Moreover, the spectral matching factors and the respective effective efficiencies (EE) are calculated for a variety of optical sensors. The material exhibits full compatibility with all the flat-panel arrays and most of the photocathodes and Si PMs considered in this work, a factor that proves its suitability for use in state-of-the-art medical imaging applications, such as CT detectors and planar arrays for projection imaging.
Collapse
|
24
|
Lewis MA, Soesbe TC, Duan X, Goshen L, Yagil Y, Gotman S, Lenkinski RE. MADplots: A methodology for visualizing and characterizing energy-dependent attenuation of tissues in spectral computed tomography. RESEARCH IN DIAGNOSTIC AND INTERVENTIONAL IMAGING 2022; 2:100011. [PMID: 39076838 PMCID: PMC11265196 DOI: 10.1016/j.redii.2022.100011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Accepted: 07/21/2022] [Indexed: 07/31/2024]
Abstract
Rationale and objectives A method for visualizing and analyzing the complete information contained in spectral CT scans using two-dimensional histograms (i.e. Material Attenuation Decomposition plots - MADplots) of the water-photoelectric attenuation versus water-scatter attenuation at the cohort (combination of multiple studies across patients), examination, series, slice, and organ/ROI levels is described. Materials and methods The appearance of a MADplot with several standard biological materials was predicted using ideal material properties available from NIST and the ICRU to generate a map for this non-spatial data space. Software tools were developed to generate MADplots as new DICOM series that facilitate spectral analysis. Illustrative examples were selected from an IRB-approved, retrospective cohort of Spectral Basis Images (SBIs) scanned using a pre-release, dual-layer detector spectral CT. Results By combining all of the voxels for contrast and non-contrast studies, the predicted appearance of the MADplot was confirmed. Locations of several kinds of tissue, the shape of the tissue distributions in normal lung, and the variations in the manner in which organ-specific MADplots change with pathology are demonstrated for the presence of fat in both the liver and pancreas highlighting the potential use for identifying pathologies on spectral CT images. Conclusions The examples of MADplots shown at cohort (combined studies), examination, series, slice, organ, and ROI levels illustrate their potential utility in analyzing and displaying spectral CT data. Future studies are directed at developing MADplot based organ segmentation and the automated detection and display of organ based pathologies.
Collapse
Affiliation(s)
- Matthew A. Lewis
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Todd C. Soesbe
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Xinhui Duan
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | | | | | | | - Robert E. Lenkinski
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
- Advanced Imaging Research Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
25
|
Numerical optimization of transmission bremsstrahlung target for intense pulsed electron beam. NUCLEAR ENGINEERING AND TECHNOLOGY 2022. [DOI: 10.1016/j.net.2021.08.021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
26
|
Lu L, Sun M, Wu T, Lu Q, Chen B, Huang B. All-inorganic perovskite nanocrystals: next-generation scintillation materials for high-resolution X-ray imaging. NANOSCALE ADVANCES 2022; 4:680-696. [PMID: 36131822 PMCID: PMC9417099 DOI: 10.1039/d1na00815c] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 12/29/2021] [Indexed: 05/04/2023]
Abstract
With super strong penetrability, high-energy X-rays can be applied to probe the inner structure of target objects under nondestructive situations. Scintillation materials can down-convert X-rays into visible light, enabling the reception of photon signals and photoelectric conversion by common sensing arrays such as photomultiplier tubes and amorphous-Si photodiode matrixes. All-inorganic perovskite nanocrystals are emerging photovoltaic and scintillation materials, with tremendous light-conversion efficiency and tunable luminous properties, exhibiting great potential for high-quality X-ray imaging. Recent advancements in nanotechnology further accelerate the performance improvement of scintillation materials. In this review, we will provide a comprehensive overview of novel all-inorganic perovskite nano-scintillators in terms of potential applications in low-dose X-ray medical radiography. Compared with conventional scintillators, the merits/drawbacks, challenges, and scintillation performance control will be the focus of this article.
Collapse
Affiliation(s)
- Lu Lu
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong SAR China
| | - Mingzi Sun
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong SAR China
| | - Tong Wu
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong SAR China
| | - Qiuyang Lu
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong SAR China
| | - Baian Chen
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong SAR China
| | - Bolong Huang
- Department of Applied Biology and Chemical Technology, The Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong SAR China
| |
Collapse
|
27
|
Montoya JC, Zhang C, Li Y, Li K, Chen GH. Reconstruction of three-dimensional tomographic patient models for radiation dose modulation in CT from two scout views using deep learning. Med Phys 2022; 49:901-916. [PMID: 34908175 PMCID: PMC9080958 DOI: 10.1002/mp.15414] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Revised: 11/11/2021] [Accepted: 11/16/2021] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND A tomographic patient model is essential for radiation dose modulation in x-ray computed tomography (CT). Currently, two-view scout images (also known as topograms) are used to estimate patient models with relatively uniform attenuation coefficients. These patient models do not account for the detailed anatomical variations of human subjects, and thus, may limit the accuracy of intraview or organ-specific dose modulations in emerging CT technologies. PURPOSE The purpose of this work was to show that 3D tomographic patient models can be generated from two-view scout images using deep learning strategies, and the reconstructed 3D patient models indeed enable accurate prescriptions of fluence-field modulated or organ-specific dose delivery in the subsequent CT scans. METHODS CT images and the corresponding two-view scout images were retrospectively collected from 4214 individual CT exams. The collected data were curated for the training of a deep neural network architecture termed ScoutCT-NET to generate 3D tomographic attenuation models from two-view scout images. The trained network was validated using a cohort of 55 136 images from 212 individual patients. To evaluate the accuracy of the reconstructed 3D patient models, radiation delivery plans were generated using ScoutCT-NET 3D patient models and compared with plans prescribed based on true CT images (gold standard) for both fluence-field-modulated CT and organ-specific CT. Radiation dose distributions were estimated using Monte Carlo simulations and were quantitatively evaluated using the Gamma analysis method. Modulated dose profiles were compared against state-of-the-art tube current modulation schemes. Impacts of ScoutCT-NET patient model-based dose modulation schemes on universal-purpose CT acquisitions and organ-specific acquisitions were also compared in terms of overall image appearance, noise magnitude, and noise uniformity. RESULTS The results demonstrate that (1) The end-to-end trained ScoutCT-NET can be used to generate 3D patient attenuation models and demonstrate empirical generalizability. (2) The 3D patient models can be used to accurately estimate the spatial distribution of radiation dose delivered by standard helical CTs prior to the actual CT acquisition; compared to the gold-standard dose distribution, 95.0% of the voxels in the ScoutCT-NET based dose maps have acceptable gamma values for 5 mm distance-to-agreement and 10% dose difference. (3) The 3D patient models also enabled accurate prescription of fluence-field modulated CT to generate a more uniform noise distribution across the patient body compared to tube current-modulated CT. (4) ScoutCT-NET 3D patient models enabled accurate prescription of organ-specific CT to boost image quality for a given body region-of-interest under a given radiation dose constraint. CONCLUSION 3D tomographic attenuation models generated by ScoutCT-NET from two-view scout images can be used to prescribe fluence-field-modulated or organ-specific CT scans with high accuracy for the overall objective of radiation dose reduction or image quality improvement for a given imaging task.
Collapse
Affiliation(s)
- Juan C Montoya
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Chengzhu Zhang
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Yinsheng Li
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Ke Li
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| | - Guang-Hong Chen
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA
| |
Collapse
|
28
|
Caputo D, Massari R. Principles of computed tomography. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00144-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
29
|
Abuzaid MM, Elshami W, Tekin HO, Sulieman A, Bradley DA. COMPARISON OF RADIATION DOSE AND IMAGE QUALITY IN HEAD CT SCANS AMONG MULTIDETECTOR CT SCANNERS. RADIATION PROTECTION DOSIMETRY 2021; 196:10-16. [PMID: 34423365 DOI: 10.1093/rpd/ncab125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 07/02/2021] [Accepted: 07/26/2021] [Indexed: 06/13/2023]
Abstract
The present study compares three different multidetector CT (MDCT) scanners for routine brain imaging in terms of image quality and radiation doses. The volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose (E) were calculated. Subjective image assessment was obtained based on a scale ranging from 1 (unacceptable) to 5 (optimum). All images scored 3.5 or over, with the 160-slice MDCT images being favoured. For the 4-, 16- and 160-slice MDCT scanners, the respective median values for CTDIvol were 57 mGy, 41 mGy, and 28 mGy; DLP values were 901 mGy.cm, 680 mGy.cm, and 551 mGy.cm; and effective doses were 2 mSv, 1.5 mSv, and 1 mSv, respectively. Compared to the 160-slice MDCT, the dose values for the 4- and 16-slice units were significantly greater. In practice, the CT modality used must be carefully selected to avoid elevated radiation doses and maintain image quality.
Collapse
Affiliation(s)
- Mohamed M Abuzaid
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah, UAE
| | - Wiam Elshami
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah, UAE
| | - H O Tekin
- Medical Diagnostic Imaging Department, College of Health Sciences, University of Sharjah, Sharjah, UAE
| | - Abdelmoneim Sulieman
- Radiology and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University, Alkharj, Kingdom of Saudi Arabia
| | - D A Bradley
- Sunway University, Centre for Applied Physics and Radiation Technologies, Jalan Universiti, 46150 PJ, Malaysia
- Department of Physics, University of Surery, Guildford, Surrey GU2 7XH, UK
| |
Collapse
|
30
|
Moseley ODI, Doherty TAS, Parmee R, Anaya M, Stranks SD. Halide perovskites scintillators: unique promise and current limitations. JOURNAL OF MATERIALS CHEMISTRY. C 2021; 9:11588-11604. [PMID: 34671480 PMCID: PMC8444306 DOI: 10.1039/d1tc01595h] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 05/28/2021] [Indexed: 05/31/2023]
Abstract
The widespread use of X- and gamma-rays in a range of sectors including healthcare, security and industrial screening is underpinned by the efficient detection of the ionising radiation. Such detector applications are dominated by indirect detectors in which a scintillating material is combined with a photodetector. Halide perovskites have recently emerged as an interesting class of semiconductors, showing enormous promise in optoelectronic applications including solar cells, light-emitting diodes and photodetectors. Here, we discuss how the same superior semiconducting properties that have catalysed their rapid development in these optoelectronic devices, including high photon attenuation and fast and efficient emission properties, also make them promising scintillator materials. By outlining the key mechanisms of their operation as scintillators, we show why reports of remarkable performance have already emerged, and describe how further learning from other optoelectronic devices will propel forward their applications as scintillators. Finally, we outline where these materials can make the greatest impact in detector applications by maximally exploiting their unique properties, leading to dramatic improvements in existing detection systems or introducing entirely new functionality.
Collapse
Affiliation(s)
- Oliver D I Moseley
- Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue Cambridge CB3 0HE UK
| | - Tiarnan A S Doherty
- Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue Cambridge CB3 0HE UK
| | - Richard Parmee
- Cheyney Design and Development, Ltd., Litlington Cambridge SG8 0SS UK
| | - Miguel Anaya
- Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue Cambridge CB3 0HE UK
- Department of Chemical Engineering & Biotechnology, University of Cambridge, Philippa Fawcett Drive Cambridge CB3 0AS UK
| | - Samuel D Stranks
- Cavendish Laboratory, University of Cambridge, JJ Thomson Avenue Cambridge CB3 0HE UK
- Department of Chemical Engineering & Biotechnology, University of Cambridge, Philippa Fawcett Drive Cambridge CB3 0AS UK
| |
Collapse
|
31
|
Sedaghat S, Langguth P, Larsen N, Campbell G, Both M, Jansen O. Diagnostic Accuracy of Dual-Layer Spectral CT Using Electron Density Images to Detect Post-Traumatic Prevertebral Hematoma of the Cervical Spine. ROFO-FORTSCHR RONTG 2021; 193:1445-1450. [PMID: 34352915 DOI: 10.1055/a-1529-7010] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE To investigate the diagnostic value of dual-layer spectral detector computed tomography (SDCT) in detecting posttraumatic prevertebral hematoma of the cervical spine by including electron density images. METHODS 38 patients with post-traumatic imaging of the cervical spine were included in this study and received both SDCT and MRI examinations. MRI was set as the reference and combined conventional/electron density (C + ED) images were compared to conventional CT (CCT) images alone. RESULTS A total of 18 prevertebral hematomas were identified. Reader 1 identified 14 of 18 and reader 2 15 of 18 prevertebral hematomas by using C + ED reconstructions. Readers 1 and 2 detected 6 and 9 of 18 hematomas on CCT, respectively. CCT showed a sensitivity of 33-50 % and a specificity of 75-80 %, while for C + ED reconstructed images the sensitivity was 77-83 % and the specificity was 85-90 %. Accuracy increased from 55-66 % to 84 % by using C + ED images. The minimum thickness for detecting hematoma on C + ED images was 3 mm. The sizes of prevertebral hematoma on CCT/C + ED were not significantly under- or overestimated compared to the MRI reference. There was a significant difference between the two readers for measuring hematoma sizes on CCT (p = 0.04). Readers showed an excellent inter-rater reliability (kappa = 0.82) for C + ED images and a moderative inter-rater reliability (kappa = 0.44) for CCT. CONCLUSION With SDCT, the diagnostic accuracy for detecting post-traumatic prevertebral hematoma is improved by using combined conventional and electron density reconstructions compared to conventional images alone. KEY POINTS · SDCT has a high potential for detecting post-traumatic prevertebral hematomas of the cervical spine by using combined conventional and electron density images.. · Prevertebral hematomas with a thickness of less than 3 mm cannot be reliably identified by SDCT.. · There is no discernible value of conventional SDCT images for diagnosing prevertebral hematoma.. CITATION FORMAT · Sedaghat S, Langguth P, Larsen N et al. Diagnostic Accuracy of Dual-Layer Spectral CT Using Electron Density Images to Detect Post-Traumatic Prevertebral Hematoma of the Cervical Spine. Fortschr Röntgenstr 2021; DOI: 10.1055/a-1529-7010.
Collapse
Affiliation(s)
- Sam Sedaghat
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein - Campus Kiel, Germany
| | - Patrick Langguth
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein - Campus Kiel, Germany
| | - Naomi Larsen
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein - Campus Kiel, Germany
| | | | - Marcus Both
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein - Campus Kiel, Germany
| | - Olav Jansen
- Department for Radiology and Neuroradiology, University Hospital Schleswig-Holstein - Campus Kiel, Germany
| |
Collapse
|
32
|
Abstract
In this review, the roles of detectors in various medical imaging techniques were described. Ultrasound, optical (near-infrared spectroscopy and optical coherence tomography) and thermal imaging, magnetic resonance imaging, computed tomography, single-photon emission tomography, positron emission tomography were the imaging modalities considered. For each methodology, the state of the art of detectors mainly used in the systems was described, emphasizing new technologies applied.
Collapse
|
33
|
On a new multi-source X-ray tube concept for minimizing imaging time in digital breast tomosynthesis. Phys Med 2021; 88:20-22. [PMID: 34167003 DOI: 10.1016/j.ejmp.2021.06.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/07/2021] [Accepted: 06/12/2021] [Indexed: 11/21/2022] Open
Abstract
Replacing moving mechanics in computed tomography (CT) and digital breast tomosynthesis (DBT) has inspired numerous projects to develop alternative X-ray sources. While less suitable for CT, DBT is a viable target application for the multi-X-ray-source array tube suggested in Becker, A.E., et al. (2020): A prototype Multi-X-ray-source array (MXA) for digital breast tomosynthesis. Physics in Medicine & Biology, 65(23), 235033. The proposed prototype MXA tube comprises rotating anode disks and a set of thermionic grid switchable cathodes. It is a first-of-a-kind X-ray tube emitting brake radiation (Bremsstrahlung), developed to minimize exposure times for DBT down to the limits set by the dynamics of the employed flat panel detectors. This commentary takes a closer look at the above article and the presented concept. The MXA is expected to be scalable for long service life. The technology has potential for further extension beyond the primary target application of mammography tomosynthesis.
Collapse
|
34
|
Modeling and Reconstruction Strategy for Compton Scattering Tomography with Scintillation Crystals. CRYSTALS 2021. [DOI: 10.3390/cryst11060641] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The recent development of energy-resolved scintillation crystals opens the way to build novel imaging concepts based on the variable energy. Among them, Compton scattering tomography (CST) is one of the most ambitious concepts. Akin to Computerized Tomography (CT), it consists in probing the attenuation map of an object of interest using external ionizing sources but strives to exploit the scattered radiation as an imaging agent. For medical applications, the scattered radiation represents 70 to 80% when the energy of the source is larger than 100 keV and results from the Compton effect. This phenomenon stands for the collision of a photon with an electron and rules the change of course and loss of energy undergone by the photon. In this article, we propose a modeling for the scattered radiation assuming polychromatic sources such as 60Co and scintillation crystals such as LBC:Ce. Further, we design a general strategy for reconstructing the electron density of the target specimen. Our results are illustrated for toy objects.
Collapse
|
35
|
Shapira N, Mei K, Noël PB. Spectral CT quantification stability and accuracy for pediatric patients: A phantom study. J Appl Clin Med Phys 2021; 22:16-26. [PMID: 33426801 PMCID: PMC7984483 DOI: 10.1002/acm2.13161] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 12/08/2020] [Accepted: 12/16/2020] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Spectral computed tomography (spectral CT) provides access to clinically relevant measures of endogenous and exogenous materials in patients. For pediatric patients, current spectral CT applications include lesion characterization, quantitative vascular imaging, assessments of tumor response to treatment, and more. OBJECTIVE The aim of this study is a comprehensive investigation of the accuracy and stability of spectral quantifications from a spectral detector-based CT system with respect to different patient sizes and radiation dose levels relevant for the pediatric population. MATERIALS AND METHODS A spectral CT phantom with tissue-mimicking materials and iodine concentrations relevant for pediatric imaging was scanned on a spectral detector CT system using a standard pediatric abdominal protocol at 100%, 67%, 33% and 10% of the nominal radiation dose level. Different pediatric patient sizes were simulated using supplemental 3D-printed extension rings. Virtual mono-energetic, iodine density, effective atomic number, and electron density results were analyzed for stability with respect to radiation dose and patient size. RESULTS Compared to conventional CT imaging, a pronounced improvement in the stability of attenuation measurements across patient size was observed when using virtual mono-energetic images. Iodine densities were within 0.1 mg/ml, effective atomic numbers were within 0.26 atomic numbers and electron density quantifications were within ±1.0% of their respective nominal values. Relative to the nominal dose clinical protocol, differences in attenuation of all tissue-mimicking materials were maintained below 1.6 HU for a 33% dose reduction, below 2.7 HU for a 67% dose reduction and below 3.7 HU for a 90% dose reduction, for all virtual mono-energetic energies equal to or greater than 50 keV. Iodine, and effective atomic number quantifications were stable to within 0.1 mg/ml and 0.06 atomic numbers, respectively, across all measured dose levels. CONCLUSION Spectral CT provides accurate and stable material quantification with respect to radiation dose reduction (up to 90%) and differing pediatric patient size. The observed consistency is an important step towards quantitative pediatric imaging at low radiation exposure levels.
Collapse
Affiliation(s)
- Nadav Shapira
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaUSA
| | - Kai Mei
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaUSA
| | - Peter B. Noël
- Department of RadiologyUniversity of PennsylvaniaPhiladelphiaUSA
- Department of Diagnostic and Interventional RadiologyTechnical University of MunichMunichGermany
| |
Collapse
|
36
|
Abstract
The introduction of photon-counting detectors is expected to be the next major breakthrough in clinical x-ray computed tomography (CT). During the last decade, there has been considerable research activity in the field of photon-counting CT, in terms of both hardware development and theoretical understanding of the factors affecting image quality. In this article, we review the recent progress in this field with the intent of highlighting the relationship between detector design considerations and the resulting image quality. We discuss detector design choices such as converter material, pixel size, and readout electronics design, and then elucidate their impact on detector performance in terms of dose efficiency, spatial resolution, and energy resolution. Furthermore, we give an overview of data processing, reconstruction methods and metrics of imaging performance; outline clinical applications; and discuss potential future developments.
Collapse
Affiliation(s)
- Mats Danielsson
- Department of Physics, KTH Royal Institute of Technology, AlbaNova University Center, SE-106 91 Stockholm, Sweden. Prismatic Sensors AB, AlbaNova University Center, SE-106 91 Stockholm, Sweden
| | | | | |
Collapse
|
37
|
Liu R, Zhang S, Zhao T, O'Sullivan JA, Williamson JF, Webb T, Porras-Chaverri M, Whiting B. Impact of bowtie filter and detector collimation on multislice CT scatter profiles: A simulation study. Med Phys 2020; 48:852-870. [PMID: 33296513 DOI: 10.1002/mp.14652] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 09/30/2020] [Accepted: 11/13/2020] [Indexed: 01/20/2023] Open
Abstract
PURPOSE To investigate via Monte Carlo simulations, the impact of scan subject size, antiscatter grid (ASG), collimator size, and bowtie filter on the distribution of scatter radiation in a typical realistically modeled third generation 16 slice diagnostic computed tomography (CT) scanner. METHODS Full radiation transport was simulated with Geant4 in a realistic CT scanner geometric model, including the imaging phantom, bowtie filter (BTF), collimators and detector assembly, except for the ASGs. An analytical method was employed to quantify the probable transmission through the ASG of each photon intersecting the detector array. Normalized scatter profiles (NSP) and scatter-to-primary-ratio (SPR) profiles were simulated for 90 and 140 kVp beams for different size phantoms and slice thicknesses. The impact of CT scatter on the reconstructed attenuation coefficient factor was also studied as were the modulating effects of phantom- and patient-tissue heterogeneities on scatter profiles. A method to characterize the relative spatial frequency content of sinogram signals was developed to assess the latter. RESULTS For the 21.4-cm diameter phantom, NSP and SPR increase linearly with collimator opening for both tube potentials, with the 90 kVp scan exhibiting slightly larger NSP and SPR. The BTF modestly modulates scatter under the phantom center, reducing the prominent off-axis lobes by factors of 1.1-1.3. The ASG reduces scatter on the central axis NSP threefold, and reduces scatter at the detectors outside the phantom shadow by factors of 25 to 500. For the phantoms with diameters of 27 and 32 cm, the scatter increases roughly three- and fourfold, respectively, demonstrating that scatter monotonically increases with phantom size, despite deployment of the ASG and BTF. In the absence of a scan subject, the ASG reduces the signal profile arising photons scattered by the BTF. Without ASG, the in-air scatter profile is relatively flat compared to the scatter profile when the ASG is present. For both 90 and 140 kVp photon spectra, the calculated attenuation coefficient decreases linearly with increasing collimation size. For both homogeneous and heterogeneous objects, NSPs are dominated by low spatial frequency content compared to the primary signal. However, the SPR, which quantifies the local magnitude of nonlinear detector response and is dominated by the high frequency content of the primary profile, can contribute strongly to high-spatial frequency streaking artifacts near high-density structures in reconstructed image artifacts. CONCLUSION Public-domain Monte Carlo codes, Geant-4 in particular, is a feasible method for characterizing CT detector response to scattered- and off-focal radiation. Our study demonstrates that the ASG substantially reduces the scatter radiation and reshapes scatter-radiation profiles and affects the accuracy with which the detector array can measure narrow-beam attenuation due its inability to distinguish between true uncollided primary and narrow-angle coherently scattered photons. Hence, incorporating the impact of detector array collimation into the forward-projection signal formation models used by iterative reconstruction algorithms is necessary to use CT for accurately characterizing material properties. While tissue heterogeneities exercise a modest influence on local NPS shape and magnitude, they do not add significant high spatial frequency content.
Collapse
Affiliation(s)
- Ruirui Liu
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Shuangyue Zhang
- Department of Electrical and Systems Engineering, Washington University, St. Louis, MO, USA
| | - Tianyu Zhao
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Joseph A O'Sullivan
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Jeffrey F Williamson
- Department of Radiation Oncology, Washington University School of Medicine, St. Louis, MO, 63110, USA
| | - Tyler Webb
- Department of Electrical and Systems Engineering, Washington University, St. Louis, MO, USA
| | - Mariela Porras-Chaverri
- Atomic, Nuclear and Molecular Sciences Research Center (CICANUM), University of Costa Rica, San José, Coast Rica
| | - Bruce Whiting
- Radiology Department, University of Pittsburgh, Pittsburgh, PA, USA
| |
Collapse
|
38
|
Shapira N, Scheuermann J, Perkins AE, Kim J, Liu LP, Karp JS, Noël PB. Quantitative positron emission tomography imaging in the presence of iodinated contrast media using electron density quantifications from dual-energy computed tomography. Med Phys 2020; 48:273-286. [PMID: 33170953 DOI: 10.1002/mp.14589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 07/31/2020] [Accepted: 11/02/2020] [Indexed: 11/10/2022] Open
Abstract
PURPOSE As preparation for future positron emission tomography (PET)/dual-energy computed tomography (DECT)T imaging modality and new possible clinical applications, the study aimed to evaluate the utility of clinically available spectral results from a DECT system for improving attenuation corrections of PET acquisitions in the presence of iodinated contrast media. The dependence of the accuracy of PET quantification values, reconstructed with conventional and spectral-based attenuation corrections, was examined as a function of the amount of iodine content and x-ray radiation exposure. METHODS Measurements were performed on commercial PET/CT and DECT systems, using a semi-anthropomorphic phantom with seven centrifuge tubes in its bore. Five different configurations of tube contents were scanned by both PET/CT and DECT. With the aim of mimicking clinically observed concentrations, in all phantom configurations the center tube contained a high concentration of radionuclide while the peripheral tubes contained a lower concentration of radionuclide. Iodine content was incrementally increased between phantom configurations by replacing iodine-free tubes with tubes that contained the original radionuclide concentration within a 10 mg/ml iodine dilution. DECT-based attenuation correction maps were generated by scaling electron density spectral results into corresponding 511 keV photon linear attenuation coefficients. RESULTS Mean SUV values obtained from the nominal PET reconstruction, using conventional CT images as input for the attenuation correction, demonstrate a monotonic increase of 8.6% when the water and radionuclide mixtures were replaced by iodine, water, and radionuclide (same level of activity) mixture. Mean SUV values obtained from the DECT-based reconstruction, in which the attenuation correction utilizes electron density values as input, demonstrate different, more stable behavior across all iodine insert configurations, with a standard deviation to mean ratio of less than 1%. This observed behavior was independent of the area size used for measurement. A minor radiation dose dependency of the electron density values (below 0.5%) was observed. This resulted in consistent (iodine independent) PET quantification behavior, which persisted even at the lowest radiation dose levels tested in our experiment, that is, 25% of the radiation dose utilized for CT acquisition in the clinical PET/CT protocol. CONCLUSIONS Utilization of DECT-generated electron density estimations for attenuation correction benefit PET quantification consistency in the presence of iodine and at nominal and low DECT radiation exposure levels. The ability to correctly account for iodinated contrast media in PET acquisitions will allow the development of new clinical applications that rely on the quantitative capabilities of spectral CT technologies and modern PET systems.
Collapse
Affiliation(s)
- Nadav Shapira
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Joshua Scheuermann
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | | | - Johoon Kim
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Leening P Liu
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Joel S Karp
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| | - Peter B Noël
- Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA.,Department of Diagnostic and Interventional Radiology, School of Medicine & klinikum rechts der Isar, Technical University of Munich, München, Germany
| |
Collapse
|
39
|
Roski F, Hammel J, Mei K, Haller B, Baum T, Kirschke JS, Pfeiffer D, Woertler K, Pfeiffer F, Noël PB, Gersing AS, Schwaiger BJ. Opportunistic osteoporosis screening: contrast-enhanced dual-layer spectral CT provides accurate measurements of vertebral bone mineral density. Eur Radiol 2020; 31:3147-3155. [PMID: 33052464 PMCID: PMC8043862 DOI: 10.1007/s00330-020-07319-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 08/04/2020] [Accepted: 09/17/2020] [Indexed: 11/28/2022]
Abstract
Objectives Osteoporosis remains under-diagnosed, which may be improved by opportunistic bone mineral density (BMD) measurements on CT. However, correcting for the influence of intravenous iodine-based contrast agent is challenging. The purpose of this study was to assess the diagnostic accuracy of iodine-corrected vertebral BMD measurements derived from non-dedicated contrast-enhanced phantomless dual-layer spectral CT (DLCT) examinations. Methods Vertebral volumetric DLCT-BMD was measured in native, arterial, and portal-venous scans of 132 patients (63 ± 16 years; 32% women) using virtual monoenergetic images (50 and 200 keV). For comparison, conventional BMD was determined using an asynchronous QCT calibration. Additionally, iodine densities were measured in the abdominal aorta (AA), inferior vena cava, and vena portae (VP) on each CT phase to adjust for iodine-related measurement errors in multivariable linear regressions and a generalized estimated equation, and conversion equations were calculated. Results BMD values derived from contrast-enhanced phases using conversion equations adjusted for individual vessel iodine concentrations of VP and/or AA showed a high agreement with those from non-enhanced scans in Bland-Altman plots. Mean absolute errors (MAE) of DLCT-BMD were 3.57 mg/ml for the arterial (R2 = 0.989) and 3.69 mg/ml for the portal-venous phase (R2 = 0.987) (conventional BMD: 4.70 [R2 = 0.983] and 5.15 mg/ml [R2 = 0.981]). In the phase-independent analysis, MAE was 4.49 mg/ml for DLCT (R2 = 0.989) (conventional BMD: 4.82 mg/ml [R2 = 0.981]). Conclusions Converted BMD derived from contrast-enhanced DLCT examinations and adjusted for individual vessel iodine concentrations showed a high agreement with non-enhanced DLCT-BMD, suggesting that opportunistic BMD measurements are feasible even in non-dedicated contrast-enhanced DLCT examinations. Key Points • Accurate BMD values can be converted from contrast-enhanced DLCT scans, independent from the used scan phase. • DLCT-BMD measurements from contrast-enhanced scans should be adjusted with iodine concentrations of portal vein and/or abdominal aorta, which significantly improves the goodness-of-fit of conversion models.
Collapse
Affiliation(s)
- Ferdinand Roski
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
| | - Johannes Hammel
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.,Biomedical Physics & Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Kai Mei
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.,Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Bernhard Haller
- Institute of Medical Statistics and Epidemiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, 81675, Munich, Germany
| | - Thomas Baum
- Department of Neuroradiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, 81675, Munich, Germany
| | - Jan S Kirschke
- Department of Neuroradiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, 81675, Munich, Germany
| | - Daniela Pfeiffer
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Klaus Woertler
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Franz Pfeiffer
- Biomedical Physics & Munich School of BioEngineering, Technical University of Munich, 85748, Garching, Germany
| | - Peter B Noël
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Alexandra S Gersing
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany
| | - Benedikt J Schwaiger
- Department of Radiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.,Department of Neuroradiology, Klinikum rechts der Isar, School of Medicine, Technical University of Munich, 81675, Munich, Germany
| |
Collapse
|
40
|
Effects of Detector Sampling on Noise Reduction in Clinical Photon-Counting Whole-Body Computed Tomography. Invest Radiol 2020; 55:111-119. [PMID: 31770298 DOI: 10.1097/rli.0000000000000616] [Citation(s) in RCA: 69] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
OBJECTIVES Reconstructing images from measurements with small pixels below the system's resolution limit theoretically results in image noise reduction compared with measurements with larger pixels. We evaluate and quantify this effect using data acquired with the small pixels of a photon-counting (PC) computed tomography scanner that can be operated in different detector pixel binning modes and with a conventional energy-integrating (EI) detector. MATERIALS AND METHODS An anthropomorphic abdominal phantom that can be extended to 3 sizes by adding fat extension rings, equipped with iodine inserts as well as human cadavers, was measured at tube voltages ranging from 80 to 140 kV. The images were acquired with the EI detector (0.6 mm pixel size at isocenter) and the PC detector operating in Macro mode (0.5 mm pixel size at iso) and ultrahigh-resolution (UHR) mode (0.25 mm pixel size at iso). Both detectors are components of the same dual-source prototype computed tomography system. During reconstruction, the modulation transfer functions were matched to the one of the EI detector. The dose-normalized contrast-to-noise ratio (CNRD) values are evaluated as a figure of merit. RESULTS Images acquired in UHR mode achieve on average approximately 6% higher CNRD compared with Macro mode at the same spatial resolution for a quantitative D40f kernel. Using a sharper B70f kernel, the improvement increases to 21% on average. In addition, the better performance of PC detectors compared with EI detectors with regard to iodine imaging has been evaluated by comparing CNRD values for Macro and EI. Combining both of these effects, a CNRD improvement of up to 34%, corresponding to a potential dose reduction of up to 43%, can be achieved for D40f. CONCLUSIONS Reconstruction of UHR data with a modulation transfer function below the system's resolution limit reduces image noise for all patient sizes and tube voltages compared with standard acquisitions. Thus, a relevant dose reduction may be clinically possible while maintaining image quality.
Collapse
|
41
|
Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiol Res Pract 2020; 2020:1403957. [PMID: 32373363 PMCID: PMC7189324 DOI: 10.1155/2020/1403957] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2019] [Accepted: 02/04/2020] [Indexed: 12/18/2022] Open
Abstract
CT and its comprehensive usage have become one of the most indispensable components in medical field especially in the diagnosis of several diseases. SECT and DECT have developed CT diagnostic potentials in several means. In this review article we have discussed the basic principles of single-energy and dual-energy computed tomography and their important physical differences which can cause better diagnostic evaluation. Moreover, different organs diagnostic evaluations through single-energy and dual-energy computed tomography have been discussed. Conventional or single-energy CT (SECT) uses a single polychromatic X-ray beam (ranging from 70 to 140 kVp with a standard of 120 kVp) emitted from a single source and received by a single detector. The concept of dual-energy computed tomography (DECT) is almost as old as the CT technology itself; DECT initially required substantially higher radiation doses (nearly two times higher than those employed in single-energy CT) and presented problems associated with spatial misregistration of the two different kV image datasets between the two separate acquisitions. The basic principles of single-energy and dual-energy computed tomography and their important physical differences can cause better diagnostic evaluation. Moreover, different organs diagnostic evaluations through single-energy and dual-energy computed tomography have been discussed. According to diverse data and statistics it is controversial to definitely indicate the accurate comparison of image quality and dose amount.
Collapse
|
42
|
Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J, Heinze S, Schlemmer HP, Ziener C, Uhrig M, Kachelrieß M. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 2020; 126:108909. [DOI: 10.1016/j.ejrad.2020.108909] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Revised: 02/09/2020] [Accepted: 02/14/2020] [Indexed: 10/25/2022]
|
43
|
Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study. Eur Radiol 2020; 30:2712-2721. [PMID: 32025830 DOI: 10.1007/s00330-019-06650-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 12/04/2019] [Accepted: 12/19/2019] [Indexed: 01/08/2023]
Abstract
OBJECTIVES To compare the scan acquisition time, radiation dose, subjective and objective image quality of two dual-source CT scanners (DSCT) for detection of acute pulmonary embolism. METHODS Two hundred twenty-one scans performed on the 2nd-generation DSCT and 354 scans on the 3rd-generation DSCT were included in this large retrospective study. In a randomized blinded design, two radiologists independently reviewed the scans using a 5-point Likert scale. Radiation dose and objective image quality parameters were calculated. RESULTS Mean acquisition time was significantly lower in the 3rd-generation DSCT (2.81 s ± 0.1 in comparison with 9.7 s ± 0.15 [mean ± SD] respectively; p < 0.0001) with the 3rd generation 3.4 times faster. The mean subjective image quality score was 4.33/5 and 4/5 for the 3rd- and 2nd-generation DSCT respectively (p < 0.0001) with strong interobserver reliability agreement. DLP, CTDIvol, and ED were significantly lower in the 3rd than the 2nd generation (175.6 ± 63.7 mGy cm; 5.3 ± 1.9 mGy and 2.8 ± 1.2 mSv in comparison with 266 ± 255 mGy.cm; 7.8 ± 2.2 mGy and 3.8 ± 4.3 mSv). Noise was significantly lower in the 3rd generation (p < 0.01). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM), a dose-insensitive index for CNR, were significantly higher in the 3rd-generation DSCT (33.5 ± 23.4; 29.0 ± 21.3 and 543.7 ± 1037 in comparison with 23.4 ± 17.7; 19.4 ± 16.0 and 170.5 ± 284.3). CONCLUSION Objective and subjective image quality are significantly higher on the 3rd-generation DSCT with significantly lower mean acquisition time and radiation dose. KEY POINTS • The 3rd-generation DSCT scanner provides an improved image quality, less perceived artifacts, and lower radiation dose in comparison with the 2nd-generation DSCT, when operating in dual-energy (DE) mode. • The 3.4-times-faster 3rd-generation DSCT scanner can be of particular value in patients with chronic lung diseases or breathing difficulties that prevent adequate breathhold.
Collapse
|
44
|
Soesbe TC, Lewis MA, Nasr K, Ananthakrishnan L, Lenkinski RE. Separating High-Z Oral Contrast From Intravascular Iodine Contrast in an Animal Model Using Dual-Layer Spectral CT. Acad Radiol 2019; 26:1237-1244. [PMID: 30314734 DOI: 10.1016/j.acra.2018.09.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 09/10/2018] [Accepted: 09/12/2018] [Indexed: 01/05/2023]
Abstract
RATIONALE AND OBJECTIVES To show that water and iodine two-material decomposition images from dual-layer dual-energy spectral X-ray computed tomography (DECT) can be used to separate intravascular iodine contrast from simultaneously administered oral tantalum, tungsten, or rhenium contrast in an animal model. MATERIALS AND METHODS In this Institutional Animal Care and Use Committee approved study, four female Fischer rats were given simultaneous intravenous and oral X-ray computed tomography contrast. Intravenous iodine contrast was administered via tail vein injection. Oral barium, tantalum, tungsten, or rhenium contrast was administered via gavage. The animals were imaged on a dual-layer DECT system at 120 kVp. Water and iodine two-material decomposition images (water equivalent and iodine equivalent images) were used for qualitative analysis. Computer simulations were performed using a customized DECT simulator to better understand why certain high-Z elements disappear in the iodine equivalent images and what is the theoretical range of elements with this property. RESULTS The iodine and barium contrast appeared only in the iodine equivalent images and could not be differentiated from each other. However, the tantalum, tungsten, and rhenium contrast only appeared in the water equivalent images. This allowed iodine contrast in the bowel wall to be easily segmented from tantalum, tungsten, and rhenium contrast in the bowel lumen. Simulations confirmed that certain high-Z elements will have pixel values of ≤0 mg iodine/mL in the iodine equivalent images due to a K-edge effect associated with DECT systems. CONCLUSIONS Dual-layer DECT can separate iodine from certain high-Z elements using water equivalent and iodine equivalent images with an increased element range compared to other DECT systems. This K-edge effect could promote the development and approval of new high-Z contrast agents for DECT.
Collapse
|
45
|
Große Hokamp N, Gilkeson R, Jordan M, Laukamp K, Neuhaus VF, Haneder S, Halliburton S, Gupta A. Virtual monoenergetic images from spectral detector CT as a surrogate for conventional CT images: Unaltered attenuation characteristics with reduced image noise. Eur J Radiol 2019; 117:49-55. [DOI: 10.1016/j.ejrad.2019.05.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 04/23/2019] [Accepted: 05/25/2019] [Indexed: 10/26/2022]
|
46
|
Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019; 39:729-743. [PMID: 31059394 PMCID: PMC6542627 DOI: 10.1148/rg.2019180115] [Citation(s) in RCA: 317] [Impact Index Per Article: 52.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2018] [Revised: 06/15/2018] [Accepted: 06/26/2018] [Indexed: 01/01/2023]
Abstract
Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.
Collapse
Affiliation(s)
- Shuai Leng
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Michael Bruesewitz
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Shengzhen Tao
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Kishore Rajendran
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Ahmed F. Halaweish
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Norbert G. Campeau
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Joel G. Fletcher
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| | - Cynthia H. McCollough
- From the Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905 (S.L., M.B., S.T., K.R., N.G.C., J.G.F., C.H.M.); and Siemens Healthcare, Malvern, Pa (A.F.H.)
| |
Collapse
|
47
|
Abdullayev N, Große Hokamp N, Lennartz S, Holz JA, Romman Z, Pahn G, Neuhaus V, Maintz D, Krug B, Borggrefe J. Improvements of diagnostic accuracy and visualization of vertebral metastasis using multi-level virtual non-calcium reconstructions from dual-layer spectral detector computed tomography. Eur Radiol 2019; 29:5941-5949. [DOI: 10.1007/s00330-019-06233-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 04/05/2019] [Accepted: 04/09/2019] [Indexed: 02/14/2023]
|
48
|
Spectral Detector Computed Tomography Pulmonary Angiography: Improved Diagnostic Assessment and Automated Estimation of Window Settings Angiography of Pulmonary Arteries From Novel Spectral Detector Computed Tomography Provides Improved Image Quality if Settings are Adjusted. J Comput Assist Tomogr 2018; 42:850-857. [PMID: 29659429 DOI: 10.1097/rct.0000000000000743] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVE This study aimed to evaluate image quality (IQ) of virtual monoenergetic images (VMIs) from novel spectral detector computed tomography angiography of the pulmonary arteries and to identify appropriate window settings for each kiloelectron volt level. MATERIALS Forty consecutive patients were included in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study.Signal- and contrast-to-noise ratios were calculated within the pulmonary trunk, and pulmonary/lobar/segmental arteries were calculated. The IQ and diagnostic certainty were rated by 2 radiologists on 5-point scales. In addition, they recorded appropriate window settings (center/width) that were linearly modeled against attenuation within the pulmonary trunk to generate generable results. RESULTS Signal- and contrast-to-noise ratios, IQ, and diagnostic certainty are significantly increased in low-kiloelectron volt VMIs (≤60 keV). Interrater agreement was excellent (ĸ = 0.89). We developed 2 linear models (R: 0.91-0.97 and R: 0.43-0.91, respectively, P ≤ 0.01), that suggest appropriate window settings. CONCLUSIONS The VMIs from spectral detector computed tomography improve objective and subjective IQ in angiography of the pulmonary arteries, if window settings are adjusted; they can be automatically estimated using reported linear models.
Collapse
|
49
|
Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography. Invest Radiol 2018; 53:457-462. [DOI: 10.1097/rli.0000000000000468] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
50
|
Große Hokamp N, Laukamp K, Lennartz S, Zopfs D, Abdullayev N, Neuhaus V, Maintz D, Borggrefe J. Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT. Eur J Radiol 2018; 104:136-142. [DOI: 10.1016/j.ejrad.2018.04.018] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2017] [Revised: 03/31/2018] [Accepted: 04/18/2018] [Indexed: 11/27/2022]
|