1
|
Laterza V, Marchegiani F, Aisoni F, Ammendola M, Schena CA, Lavazza L, Ravaioli C, Carra MC, Costa V, De Franceschi A, De Simone B, de’Angelis N. Smart Operating Room in Digestive Surgery: A Narrative Review. Healthcare (Basel) 2024; 12:1530. [PMID: 39120233 PMCID: PMC11311806 DOI: 10.3390/healthcare12151530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Revised: 07/24/2024] [Accepted: 07/29/2024] [Indexed: 08/10/2024] Open
Abstract
The introduction of new technologies in current digestive surgical practice is progressively reshaping the operating room, defining the fourth surgical revolution. The implementation of black boxes and control towers aims at streamlining workflow and reducing surgical error by early identification and analysis, while augmented reality and artificial intelligence augment surgeons' perceptual and technical skills by superimposing three-dimensional models to real-time surgical images. Moreover, the operating room architecture is transitioning toward an integrated digital environment to improve efficiency and, ultimately, patients' outcomes. This narrative review describes the most recent evidence regarding the role of these technologies in transforming the current digestive surgical practice, underlining their potential benefits and drawbacks in terms of efficiency and patients' outcomes, as an attempt to foresee the digestive surgical practice of tomorrow.
Collapse
Affiliation(s)
- Vito Laterza
- Department of Digestive Surgical Oncology and Liver Transplantation, University Hospital of Besançon, 3 Boulevard Alexandre Fleming, 25000 Besancon, France;
| | - Francesco Marchegiani
- Unit of Colorectal and Digestive Surgery, DIGEST Department, Beaujon University Hospital, AP-HP, University of Paris Cité, Clichy, 92110 Paris, France
| | - Filippo Aisoni
- Unit of Emergency Surgery, Department of Surgery, Ferrara University Hospital, 44124 Ferrara, Italy;
| | - Michele Ammendola
- Digestive Surgery Unit, Health of Science Department, University Hospital “R.Dulbecco”, 88100 Catanzaro, Italy;
| | - Carlo Alberto Schena
- Unit of Robotic and Minimally Invasive Surgery, Department of Surgery, Ferrara University Hospital, 44124 Ferrara, Italy; (C.A.S.); (N.d.)
| | - Luca Lavazza
- Hospital Network Coordinator of Azienda Ospedaliero, Universitaria and Azienda USL di Ferrara, 44121 Ferrara, Italy;
| | - Cinzia Ravaioli
- Azienda Ospedaliero, Universitaria di Ferrara, 44121 Ferrara, Italy;
| | - Maria Clotilde Carra
- Rothschild Hospital (AP-HP), 75012 Paris, France;
- INSERM-Sorbonne Paris Cité, Epidemiology and Statistics Research Centre, 75004 Paris, France
| | - Vittore Costa
- Unit of Orthopedics, Humanitas Hospital, 24125 Bergamo, Italy;
| | | | - Belinda De Simone
- Department of Emergency Surgery, Academic Hospital of Villeneuve St Georges, 91560 Villeneuve St. Georges, France;
| | - Nicola de’Angelis
- Unit of Robotic and Minimally Invasive Surgery, Department of Surgery, Ferrara University Hospital, 44124 Ferrara, Italy; (C.A.S.); (N.d.)
- Department of Translational Medicine, University of Ferrara, 44121 Ferrara, Italy
| |
Collapse
|
2
|
Pilz da Cunha G, van Delden OM, Kazemier G, Vahrmeijer AL, Bonjer HJ, Meijerink MR, Swijnenburg RJ. Hybrid operating room applications for precision hepatobiliary surgery: A narrative review. J Surg Oncol 2024; 129:1265-1273. [PMID: 38567691 DOI: 10.1002/jso.27634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Accepted: 03/17/2024] [Indexed: 06/04/2024]
Abstract
This review summarizes the key applications of a hybrid operating room (HOR) in hepatobiliary surgery and explores the advantages, limitations, and future directions of its utilization. A comprehensive literature search was conducted in PubMed to identify articles reporting on the utilization of HORs in liver surgery. So far, the HOR has been limitedly applied in hepatobiliary surgery. It can offer an optimal environment for combining radiological and surgical interventions and for performing image-guided surgical navigation.
Collapse
Affiliation(s)
- Gabriela Pilz da Cunha
- Department of Surgery, Amsterdam UMC Location, University of Amsterdam, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
| | - Otto M van Delden
- Department of Radiology, Amsterdam UMC Location Amsterdam Medical Center, Amsterdam, The Netherlands
| | - Geert Kazemier
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Alexander L Vahrmeijer
- Department of Surgical Oncology, Leiden University Medical Center, Leiden, The Netherlands
| | - H Jaap Bonjer
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Martijn R Meijerink
- Department of Radiology, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Rutger-Jan Swijnenburg
- Cancer Center Amsterdam, Treatment and Quality of Life, Amsterdam, The Netherlands
- Department of Surgery, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Skyrman S, Lai M, Edström E, Burström G, Förander P, Homan R, Kor F, Holthuizen R, Hendriks BHW, Persson O, Elmi-Terander A. Augmented reality navigation for cranial biopsy and external ventricular drain insertion. Neurosurg Focus 2021; 51:E7. [PMID: 34333469 DOI: 10.3171/2021.5.focus20813] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 05/17/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the accuracy (deviation from the target or intended path) and efficacy (insertion time) of an augmented reality surgical navigation (ARSN) system for insertion of biopsy needles and external ventricular drains (EVDs), two common neurosurgical procedures that require high precision. METHODS The hybrid operating room-based ARSN system, comprising a robotic C-arm with intraoperative cone-beam CT (CBCT) and integrated video tracking of the patient and instruments using nonobtrusive adhesive optical markers, was used. A 3D-printed skull phantom with a realistic gelatinous brain model containing air-filled ventricles and 2-mm spherical biopsy targets was obtained. After initial CBCT acquisition for target registration and planning, ARSN was used for 30 cranial biopsies and 10 EVD insertions. Needle positions were verified by CBCT. RESULTS The mean accuracy of the biopsy needle insertions (n = 30) was 0.8 mm ± 0.43 mm. The median path length was 39 mm (range 16-104 mm) and did not correlate to accuracy (p = 0.15). The median device insertion time was 149 seconds (range 87-233 seconds). The mean accuracy for the EVD insertions (n = 10) was 2.9 mm ± 0.8 mm at the tip with a 0.7° ± 0.5° angular deviation compared with the planned path, and the median insertion time was 188 seconds (range 135-400 seconds). CONCLUSIONS This study demonstrated that ARSN can be used for navigation of percutaneous cranial biopsies and EVDs with high accuracy and efficacy.
Collapse
Affiliation(s)
- Simon Skyrman
- 1Department of Neurosurgery, Karolinska University Hospital, and Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Marco Lai
- 2Philips Research, High Tech Campus 34, Eindhoven.,3Eindhoven University of Technology (TU/e), Eindhoven
| | - Erik Edström
- 1Department of Neurosurgery, Karolinska University Hospital, and Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Gustav Burström
- 1Department of Neurosurgery, Karolinska University Hospital, and Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Petter Förander
- 1Department of Neurosurgery, Karolinska University Hospital, and Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | | | - Flip Kor
- 5Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | | | - Benno H W Hendriks
- 2Philips Research, High Tech Campus 34, Eindhoven.,5Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Oscar Persson
- 1Department of Neurosurgery, Karolinska University Hospital, and Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Adrian Elmi-Terander
- 1Department of Neurosurgery, Karolinska University Hospital, and Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
4
|
Venous anatomy of the infratentorial compartment. HANDBOOK OF CLINICAL NEUROLOGY 2021; 169:73-86. [PMID: 32553299 DOI: 10.1016/b978-0-12-804280-9.00004-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Abstract
Approximately 7%-12% of all intracranial meningiomas are located in the posterior fossa (PF), a region which contains-among many other critical neurovascular structures-numerous major veins and sinuses draining blood away from the PF structures. There is a growing body of evidence indicating that venous sacrifice or injury during surgery are linked to serious postoperative complications-which may lead to significant morbidity and mortality. Thus, it is of paramount importance that clinicians charged with the preoperative, surgical, and postoperative care of patients undergoing treatment for meningioma are familiar with the general anatomy of the PF veins, as well as their structural nuances and drainage variations. The present chapter surveys the relevant anatomy in a manner that aims to be useful for an interdisciplinary team of clinicians and concludes with a discussion of emerging imaging technologies that may assist them in their clinical decision-making.
Collapse
|
5
|
Abstract
BACKGROUND AND OBJECTIVE The hybrid operating room has been widely applied in surgery, including neurology, general surgery, gynecology, and obstetrics. By reviewing application of the hybrid operating room in different categories of surgery, we aim to summarize both advantages and disadvantages of the hybrid operating room and discuss what to do for further improving the application of it. METHODS We searched related literature in websites including Pubmed, MEDLINE, Web of science, using the keywords "hybrid operating room", "surgery", "technique", "intervention", and "radiology". All the searched papers were screened and underwent quality evaluation. The eventually selected papers were carefully read, with related information extracted and summarized. RESULTS After screening and assessment, a total of 29 literature was collected. Application of the hybrid operating room in general surgery, neurosurgery, thoracic surgery, urology, gynecologic and obstetrics surgery, and cardiovascular surgery was summarized. Both advantages and disadvantages of the hybrid operating room were discussed in order to improve application of the hybrid operating room in surgery. CONCLUSIONS Surgeries performed in the hybrid operating room take advantages over those conventional operating rooms mainly in terms of higher procedure accuracy, less operative time, and less risk of hemorrhage during the transportation between radiology departments and operating suites. Further efforts should be made to reduce radiation exposure from imaging systems equipped in the hybrid operating room and increase cost-effectiveness ratio of the hybrid operating room.
Collapse
Affiliation(s)
- Hao Jin
- The Second Department of General Surgery, Zhuhai People's Hospital (Zhuhai Hospital Affiliated with Jinan University), Zhuhai, Guangdong, China
| | - Junwei Liu
- Zhuhai Health Bureau, Zhuhai, Guangdong, China
| |
Collapse
|
6
|
Intraoperative cone beam computed tomography is as reliable as conventional computed tomography for identification of pedicle screw breach in thoracolumbar spine surgery. Eur Radiol 2020; 31:2349-2356. [PMID: 33006659 PMCID: PMC7979653 DOI: 10.1007/s00330-020-07315-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 08/04/2020] [Accepted: 09/17/2020] [Indexed: 12/01/2022]
Abstract
Objectives To test the hypothesis that intraoperative cone beam computed tomography (CBCT) using the Allura augmented reality surgical navigation (ARSN) system in a dedicated hybrid operating room (OR) matches computed tomography (CT) for identification of pedicle screw breach during spine surgery. Methods Twenty patients treated with spinal fixation surgery (260 screws) underwent intraoperative CBCT as well as conventional postoperative CT scans (median 12 months after surgery) to identify and grade the degree of pedicle screw breach on both scan types, according to the Gertzbein grading scale. Blinded assessments were performed by three independent spine surgeons and the CT served as the standard of reference. Screws graded as Gertzbein 0 or 1 were considered clinically accurate while grades 2 or 3 were considered inaccurate. Sensitivity, specificity, and negative predictive value were the primary metrics of diagnostic performance. Results For this patient group, the negative predictive value of an intraoperative CBCT to rule out pedicle screw breach was 99.6% (CI 97.75–99.99%). Among 10 screws graded as inaccurate on CT, 9 were graded as such on the CBCT, giving a sensitivity of 90.0% (CI 55.5–99.75%). Among the 250 screws graded as accurate on CT, 244 were graded as such on the CBCT, giving a specificity of 97.6% (CI 94.85–99.11%). Conclusions CBCT, performed intraoperatively with the Allura ARSN system, is comparable and non-inferior to a conventional postoperative CT scan for ruling out misplaced pedicle screws in spinal deformity cases, eliminating the need for a postoperative CT. Key Points • Intraoperative cone beam computed tomography (CT) using the Allura ARSN is comparable with conventional CT for ruling out pedicle screw breaches after spinal fixation surgery. • Intraoperative cone beam computed tomography can be used to assess need for revisions of pedicle screws making routine postoperative CT scans unnecessary. • Using cone beam computed tomography, the specificity was 97.6% and the sensitivity was 90% for detecting pedicle screw breaches and the negative predictive value for ruling out a pedicle screw breach was 99.6%.
Collapse
|