1
|
Feleni U, Morare R, Masunga GS, Magwaza N, Saasa V, Madito MJ, Managa M. Recent developments in waterborne pathogen detection technologies. ENVIRONMENTAL MONITORING AND ASSESSMENT 2025; 197:233. [PMID: 39903332 PMCID: PMC11794368 DOI: 10.1007/s10661-025-13644-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2024] [Accepted: 01/14/2025] [Indexed: 02/06/2025]
Abstract
Waterborne pathogens find their way into water bodies through contamination of fecal discharge, stormwater run-offs, agriculture and industrial activities, and poor water infrastructure. These organisms are responsible for causing diarrheal, gastroenteritis, cholera, and typhoid diseases which raise an alarming sense on public human health due to the high mortality rate, especially in children. Several studies have indicated that these waterborne diseases can be managed by monitoring pathogens in water using traditional culture-based and molecular techniques. However, these methods have shown several setbacks such as the longer duration for detection and the inability to detect pathogens at low concentrations. Effective management of these diseases requires rapid, sensitive, highly selective, fast, and efficient economic methods to monitor pathogens in water. Since the creation of biosensors, these tools have been applied and shown the ability to detect pathogens at low concentrations. The highlights of biosensor systems are that they are fast, portable, easy to use, highly sensitive, and specific. The capabilities of biosensors have given these tools exposure to be widely applied in detecting pharmaceutical pollutants, pesticides, toxins, residues of detergents, and cosmetics from household activities in soil and water. With such difficulties faced for detecting waterborne pathogens, this review evaluates the effectiveness of technologies for waterborne pathogens detection and their drawbacks. It further highlights biosensors as the current reliable method available for detecting pathogens in water and its future capabilities in sustaining safe potable water.
Collapse
Affiliation(s)
- Usisipho Feleni
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park 1710, Johannesburg, South Africa.
| | - Rebotiloe Morare
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park 1710, Johannesburg, South Africa
| | - Ginny S Masunga
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park 1710, Johannesburg, South Africa
| | - Nontokozo Magwaza
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park 1710, Johannesburg, South Africa
| | - Valentine Saasa
- Department of Life and Consumer Sciences, College of Agriculture and Environmental Sciences, University of South Africa (UNISA), Florida Campus, Roodepoort, 1709, South Africa
| | - Moshawe J Madito
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park 1710, Johannesburg, South Africa
| | - Muthumuni Managa
- Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Florida Campus, Florida Park 1710, Johannesburg, South Africa
| |
Collapse
|
2
|
Fernández Blanco A, Moreno Y, García-Hernández J, Hernández M. A Photonic Immunosensor Detection Method for Viable and Non-Viable E. coli in Water Samples. Microorganisms 2024; 12:1328. [PMID: 39065096 PMCID: PMC11278787 DOI: 10.3390/microorganisms12071328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 06/17/2024] [Accepted: 06/21/2024] [Indexed: 07/28/2024] Open
Abstract
Detection and enumeration of coliform bacteria using traditional methods and current molecular techniques against E. coli usually involve long processes with less sensitivity and specificity to distinguish between viable and non-viable bacteria for microbiological water analysis. This approach involves developing and validating an immunosensor comprising ring resonators functionalized with specific antibodies surrounded by a network of microchannels as an alternative method for detecting and indirectly enumerating Escherichia coli in samples of water for consumption. Different ELISA assays were conducted to characterize monoclonal and polyclonal antibodies selected as detection probes for specific B-galactosidase enzymes and membrane LPS antigens of E. coli. An immobilization control study was performed on silicon nitride surfaces used in the immunosensor, immobilized with the selected antibodies from the ELISA assays. The specificity of this method was confirmed by detecting as few as 10 CFU/mL of E. coli from viable and non-viable target bacteria after applying various disinfection methods to water samples intended for human consumption. The 100% detection rate and a 100 CFU/mL Limit of Quantification of the proposed method were validated through a comprehensive assessment of the immunosensor-coupled microfluidic system, involving at least 50 replicates with a concentration range of 10 to 106 CFU/mL of the target bacteria and 50 real samples contaminated with and without disinfection treatment. The correlation coefficient of around one calculated for each calibration curve obtained from the results demonstrated sensitive and rapid detection capabilities suitable for application in water resources intended for human consumption within the food industry. The biosensor was shown to provide results in less than 4 h, allowing for rapid identification of microbial contamination crucial for ensuring water monitoring related to food safety or environmental diagnosis and allowing for timely interventions to mitigate contamination risks. Indeed, the achieved setup facilitates the in situ execution of laboratory processes, allowing for the detection of both viable and non-viable bacteria, and it implies future developments of simultaneous detection of pathogens in the same contaminated sample.
Collapse
Affiliation(s)
| | - Yolanda Moreno
- Institute of Water and Environmental Engineering, Universitat Politècnica de València, 46022 Valencia, Spain
| | - Jorge García-Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain; (J.G.-H.); (M.H.)
| | - Manuel Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain; (J.G.-H.); (M.H.)
| |
Collapse
|
3
|
Barbosa A, Azevedo NF, Goeres DM, Cerqueira L. Ecology of Legionella pneumophila biofilms: The link between transcriptional activity and the biphasic cycle. Biofilm 2024; 7:100196. [PMID: 38601816 PMCID: PMC11004079 DOI: 10.1016/j.bioflm.2024.100196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 03/10/2024] [Accepted: 03/29/2024] [Indexed: 04/12/2024] Open
Abstract
There has been considerable discussion regarding the environmental life cycle of Legionella pneumophila and its virulence potential in natural and man-made water systems. On the other hand, the bacterium's morphogenetic mechanisms within host cells (amoeba and macrophages) have been well documented and are linked to its ability to transition from a non-virulent, replicative state to an infectious, transmissive state. Although the morphogenetic mechanisms associated with the formation and detachment of the L. pneumophila biofilm have also been described, the capacity of the bacteria to multiply extracellularly is not generally accepted. However, several studies have shown genetic pathways within the biofilm that resemble intracellular mechanisms. Understanding the functionality of L. pneumophila cells within a biofilm is fundamental for assessing the ecology and evaluating how the biofilm architecture influences L. pneumophila survival and persistence in water systems. This manuscript provides an overview of the biphasic cycle of L. pneumophila and its implications in associated intracellular mechanisms in amoeba. It also examines the molecular pathways and gene regulation involved in L. pneumophila biofilm formation and dissemination. A holistic analysis of the transcriptional activities in L. pneumophila biofilms is provided, combining the information of intracellular mechanisms in a comprehensive outline. Furthermore, this review discusses the techniques that can be used to study the morphogenetic states of the bacteria within biofilms, at the single cell and population levels.
Collapse
Affiliation(s)
- Ana Barbosa
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Nuno F. Azevedo
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - Darla M. Goeres
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- The Center for Biofilm Engineering, Montana State University, Bozeman, MT, USA
| | - Laura Cerqueira
- LEPABE – Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE – Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| |
Collapse
|
4
|
Gao M, Tan F, Shen Y, Peng Y. Rapid detection method of bacterial pathogens in surface waters and a new risk indicator for water pathogenic pollution. Sci Rep 2024; 14:1614. [PMID: 38238351 PMCID: PMC10796392 DOI: 10.1038/s41598-023-49774-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Accepted: 12/12/2023] [Indexed: 01/22/2024] Open
Abstract
In this study, a accurate, rapid quantitative PCR method for the simultaneous detection of 4 kinds of pathogenic bacteria in water was established, and the distribution of pathogenic bacteria in surface waters with different levels of pollution (Yulin region, China) was detected. The results showed that the detection accuracy was 94%; the detection limit was 2.7 in bacterial cells. Salmonella enterica subsp. enterica serovar typhimurium and Salmonella dysenteria were always present in water when the universal primer for pathogenic bacteria abundance detection was greater than 104 copies 100 mL-1. When the detection value is lower than 104 copy 100 mL-1, the bacteria in the water are rarely pathogenic bacteria, so the detection value of 104 copy 100 mL-1 can be used as a new indicator of waterborne pathogen pollution.
Collapse
Affiliation(s)
- Min Gao
- College of Environmental and Chemical Engineering, Xi'an Key Laboratory of Textile Chemical Engineering Auxiliaries, Xi'an Polytechnic University, Xi'an, 710000, People's Republic of China.
| | - Feiyang Tan
- College of Environmental and Chemical Engineering, Xi'an Key Laboratory of Textile Chemical Engineering Auxiliaries, Xi'an Polytechnic University, Xi'an, 710000, People's Republic of China
| | - Yuan Shen
- College of Environmental and Chemical Engineering, Xi'an Key Laboratory of Textile Chemical Engineering Auxiliaries, Xi'an Polytechnic University, Xi'an, 710000, People's Republic of China
| | - Yao Peng
- College of Environmental and Chemical Engineering, Xi'an Key Laboratory of Textile Chemical Engineering Auxiliaries, Xi'an Polytechnic University, Xi'an, 710000, People's Republic of China
| |
Collapse
|
5
|
Community Composition and Antibiotic Resistance of Tap Water Bacteria Retained on Filtration Membranes. DIVERSITY 2023. [DOI: 10.3390/d15030427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
Community composition and antibiotic resistance of tap water bacteria are still not known well enough. This study fills the gaps in knowledge regarding this matter. To provide representativeness of collected samples, tap water bacteria were concentrated from huge amounts of water, using filtration membranes monthly during the continuous, semi-annual study, covering winter and spring seasons. Biomass was investigated both using a culture-based method (for total and antibiotic-resistant culturable bacteria counts) and metagenomic DNA sequencing (for taxonomic identification of bacteria). The results showed that bacteria resistant to ceftazidime were the most prevalent among the studied resistance phenotypes, whereas bacteria resistant to amoxicillin, ciprofloxacin, and tetracycline were scarce. On average, 20,059 and 26,200 CFU/mL per month was counted in the winter and spring season, respectively, whereas in terms of antibiotic-resistant bacteria, average counts were 14,270 and 9435 CFU/mL per month in the winter and spring season, respectively. In terms of bacterial community composition, Cyanobacteria, Proteobacteria and Actinobacteria were the most abundant phyla, reaching up to 77.71%, 74.40% and 21.85%, respectively, which is supported by previous studies conducted on the same water supply network and other drinking water distribution systems across the world. No season-dependent variations were observed for culturable antibiotic-resistant bacteria or bacterial community composition. The prevalence of culturable antibiotic-resistant bacteria was not correlated with any of the identified taxa.
Collapse
|
6
|
Lim HJ, Hong S, Jin H, Chua B, Son A. A multi-functional reagent suitable for 1-step rapid DNA intercalation fluorescence-based screening of total bacteria in drinking water. CHEMOSPHERE 2023; 313:137541. [PMID: 36526135 DOI: 10.1016/j.chemosphere.2022.137541] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 12/09/2022] [Accepted: 12/10/2022] [Indexed: 06/17/2023]
Abstract
The prerequisites for rapid screening of total bacteria in drinking water are low detection limit and convenience. Inspired by commercial adenosine 5'-triphosphate (ATP) based total bacterial detection kits, we pursued likewise convenience but with much lower detection limit. Existing intercalation fluorescence-based techniques employ multiple reagents to permeate the cell membrane and intercalate dye into the DNA in discrete sequential steps. A simple multi-functional reagent is proposed to do the same within one step. Surfactants (TritonX and SDS), and intercalating dyes (SYBR green, SYBR gold) were examined for their mutual compatibility and augmented with EDTA. Evaluation was performed with Gram negative Escherichia coli K12 (E. coli K12) and Gram positive Bacillus subtilis (B. subtilis) at serial dilution ratios from 10-6 to 10-2. Comparison was made with absorbance (600 nm) measurements and a commercial ATP kit. Using charge integrated photodetection, the proposed 1-step reagent achieved an LOD (1.00 × 10-6, B. subtilis) that is two orders of magnitude lower than that of ATP kit (LOD = 1.06× 10-4). This means it could detect minute quantity of total bacteria that is otherwise undetected by the ATP kit.
Collapse
Affiliation(s)
- Hyun Jeong Lim
- Department of Environmental Science and Engineering, Ewha Womans University, Seoul 03760, Republic of Korea; Department of Chemical and Environmental Engineering, Yale University, New Haven, CT 06511, USA
| | - Seungwon Hong
- Department of Environmental Science and Engineering, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Hyowon Jin
- Department of Environmental Science and Engineering, Ewha Womans University, Seoul 03760, Republic of Korea
| | - Beelee Chua
- School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea.
| | - Ahjeong Son
- Department of Environmental Science and Engineering, Ewha Womans University, Seoul 03760, Republic of Korea.
| |
Collapse
|
7
|
El Boujnouni H, Nait Balla K, Belkadi B, Rahouti M. Comparison between the recovery rate of three concentration protocols of water samples intended for analysis by Molecular Biology: Membrane filtration, filtration on gauze pad and centrifugation. Saudi J Biol Sci 2022; 29:1592-1597. [PMID: 35280573 PMCID: PMC8913413 DOI: 10.1016/j.sjbs.2021.11.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 10/29/2021] [Accepted: 11/04/2021] [Indexed: 11/17/2022] Open
Affiliation(s)
- Hamoucha El Boujnouni
- Team of Botany and Valorization of Plant and Fungal Resources Plant and Microbial Biotechnologies, Biodiversity and Environment Research Center, Faculty of Sciences, Mohammed V University in Rabat, B.P. 1014 RP, Rabat, Morocco
- Corresponding author.
| | - Kaoutar Nait Balla
- Team of Microbiology and Molecular Biology, Plant and Microbial Biotechnologies, Biodiversity and Environment Research Center, Faculty of Sciences, Mohammed V University in Rabat, B.P. 1014 RP, Rabat, Morocco
| | - Bouchra Belkadi
- Team of Microbiology and Molecular Biology, Plant and Microbial Biotechnologies, Biodiversity and Environment Research Center, Faculty of Sciences, Mohammed V University in Rabat, B.P. 1014 RP, Rabat, Morocco
| | - Mohamed Rahouti
- Team of Botany and Valorization of Plant and Fungal Resources Plant and Microbial Biotechnologies, Biodiversity and Environment Research Center, Faculty of Sciences, Mohammed V University in Rabat, B.P. 1014 RP, Rabat, Morocco
| |
Collapse
|
8
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
9
|
Drinkwater R, Goodwin A, Cush J, Korstian JM, Chumchal MM, Herrera M. LG, Valdez M, Otálora-Ardila A, Flores-Martinez JJ, Clare EL. Molecular diet analysis of the marine fish-eating bat (Myotis vivesi) and potential mercury exposure. CAN J ZOOL 2021. [DOI: 10.1139/cjz-2021-0018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Mercury is a toxic element acquired by animals through feeding which can accumulate within food chains through biomagnification. This possesses particular risks to higher trophic levels and may unduly impact marine foraging species or individuals. The fish-eating bat (Myotis vivesi Menegaux, 1901) inhabits islands in the Gulf of California and can act as a predator in the marine environment. A predominantly marine diet and a high trophic position increase the risk of mercury exposure owing to increased bioaccumulation. Using molecular techniques to reconstruct diet, we show that M. vivesi regularly feeds on small fishes and crustaceans, particularly on the Californian anchovy (Engraulis mordax Girard, 1854) and a krill species (Nyctiphanes simplex Hansen, 1911). Additionally, we identify significant interannual variation in diet composition within this population, but measured levels of total mercury in faecal samples were not related to dietary diversity or trophic level.
Collapse
Affiliation(s)
- Rosie Drinkwater
- School of Biological and Chemical Sciences, Queen Mary University of London, Mile End Road, E14NS, UK
| | - Alice Goodwin
- School of Biological and Chemical Sciences, Queen Mary University of London, Mile End Road, E14NS, UK
| | - Jake Cush
- School of Biological and Chemical Sciences, Queen Mary University of London, Mile End Road, E14NS, UK
| | - Jennifer M. Korstian
- Department of Biology, Texas Christian University, 2800 South University Drive, Fort Worth, TX 76109, USA
| | - Matthew M. Chumchal
- Department of Biology, Texas Christian University, 2800 South University Drive, Fort Worth, TX 76109, USA
| | - L. Gerardo Herrera M.
- Estación de Biología de Chamela, Instituto de Biología, Universidad Nacional Autónoma de México, San Patricio, Jalisco 48980, México
| | - Martha Valdez
- Departamento de Ecología y Sistemática Acuática, El Colegio de la Frontera Sur, Chetumal, Chetumal 77014, México
| | - Aída Otálora-Ardila
- Posgrado en Ciencias Biológicas, Instituto de Biología, Universidad Nacional Autónoma de México, Circuito Exterior s/n, Ciudad Universitaria, Ciudad de México, 04510, México
- Grupo en conservación y manejo de vida silvestre, Universidad Nacional de Colombia, Bogotá, Colombia
| | - José Juan Flores-Martinez
- Laboratorio de Sistemas de Información Geográfica, Instituto de Biología, Universidad Nacional Autónoma de México, Ciudad de México, 04510, México
| | - Elizabeth L. Clare
- School of Biological and Chemical Sciences, Queen Mary University of London, Mile End Road, E14NS, UK
- Department of Biology, York University, Toronto, ON M3J 1P3, Canada
| |
Collapse
|
10
|
Zhang C, Qin K, Struewing I, Buse H, Santo Domingo J, Lytle D, Lu J. The Bacterial Community Diversity of Bathroom Hot Tap Water Was Significantly Lower Than That of Cold Tap and Shower Water. Front Microbiol 2021; 12:625324. [PMID: 33967975 PMCID: PMC8102780 DOI: 10.3389/fmicb.2021.625324] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 02/12/2021] [Indexed: 12/17/2022] Open
Abstract
Microbial drinking water quality in premise plumbing systems (PPSs) strongly affects public health. Bacterial community structure is the essential aspect of microbial water quality. Studies have elucidated the microbial community structure in cold tap water, while the microbial community structures in hot tap and shower water are poorly understood. We sampled cold tap, hot tap, and shower water from a simulated PPS monthly for 16 consecutive months and assessed the bacterial community structures in those samples via high-throughput sequencing of bacterial 16S rRNA genes. The total relative abundance of the top five most abundant phyla (Proteobacteria, Actinobacteria, Bacteroidetes, Cyanobacteria, and Firmicutes) was greater than 90% among the 24 identified phyla. The most abundant families were Burkholderiaceae, Sphingomonadaceae, unclassified Alphaproteobacteria, unclassified Corynebacteriales, and Mycobacteriaceae. A multiple linear regression suggests that the bacterial community diversity increased with water temperature and the age of the simulated PPS, decreased with total chlorine residual concentration, and had a limited seasonal variation. The bacterial community in hot tap water had significantly lower Shannon and Inverse Simpson diversity indices (p < 0.05) and thus a much lower diversity than those in cold tap and shower water. The paradoxical results (i.e., diversity increased with water temperature, but hot tap water bacterial community was less diverse) were presumably because (1) other environmental factors made hot tap water bacterial community less diverse, (2) the diversity of bacterial communities in all types of water samples increased with water temperature, and (3) the first draw samples of hot tap water could have a comparable or even lower temperature than shower water samples and the second draw samples of cold tap water. In both a three-dimensional Non-metric multidimensional scaling ordination plot and a phylogenetic dendrogram, the samples of cold tap and shower water cluster and are separate from hot tap water samples (p < 0.05). In summary, the bacterial community in hot tap water in the simulated PPS had a distinct structure from and a much lower diversity than those in cold tap and shower water.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Ke Qin
- Oak Ridge Institute for Science and Education Participation Program, Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Helen Buse
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Jorge Santo Domingo
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Darren Lytle
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|