Leung LW, Evranos B, Gonna H, Harding I, Domenichini G, Gallagher MM. Multi-catheter cryotherapy for the treatment of resistant accessory pathways. Indian Pacing Electrophysiol J 2024; 24:1-5. [PMID: 37977548 PMCID: PMC10927982 DOI: 10.1016/j.ipej.2023.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/25/2023] [Accepted: 11/02/2023] [Indexed: 11/19/2023] Open
Abstract
OBJECTIVE To investigate the utility of simultaneous multi-catheter cryotherapy for the treatment of APs that were previously resistant to standard radiofrequency (RF) catheter ablation. BACKGROUND Catheter ablation is established in the treatment of accessory pathways (AP), with high rates of permanent procedural success with a single attempt. However, there are still instances of acute procedural failure and AP recurrences with standard RF and cryotherapy methods. METHODS Seven consecutive cases of pre-excitation syndromes with prior failed RF catheter ablation had the novel treatment. Cryotherapy was delivered using two 8 mm tip focal cryoablation catheters (Freezor® Max, Medtronic, Minneapolis, Minnesota, USA). RESULTS Accessory pathway localisation was septal in 5 cases, left posterolateral in 1, right lateral in 1. In all cases, ablation of the AP was acutely successful with no procedural complications. Median procedure and fluoroscopy durations were 199 and 35 min, sequentially. Median Procedure duration fell significantly in the second half of series (174 min) compared to the first half (233 min, P = 0.05). One patient had evidence of a recurring AP conduction with pre-excitation at 5-week follow up. After a median follow up of 66.8+-6.5 months, 6 out of 7 patients remained asymptomatic and free of pre-excitation. CONCLUSION Simultaneous multi-catheter cryotherapy is feasible, safe and can provide definitive cure of accessory pathways that were previously resistant to standard radiofrequency ablation. Further study is required in the assessment of this novel form of advanced cryotherapy to treat complex and resistant arrhythmias.
Collapse
Affiliation(s)
- Lisa Wm Leung
- Department of Cardiology, St. George's University Hospitals NHS Foundation Trust, UK
| | - Banu Evranos
- Department of Cardiology, St. George's University Hospitals NHS Foundation Trust, UK
| | - Hanney Gonna
- Department of Cardiology, St. George's University Hospitals NHS Foundation Trust, UK
| | - Idris Harding
- Department of Cardiology, St. George's University Hospitals NHS Foundation Trust, UK
| | - Giulia Domenichini
- Department of Cardiology, St. George's University Hospitals NHS Foundation Trust, UK
| | - Mark M Gallagher
- Department of Cardiology, St. George's University Hospitals NHS Foundation Trust, UK.
| |
Collapse
|
2
|
Patel P, Krishnan K, Saha S, Trohman RG. Novel Implantable Cardioverter-defibrillator Lead Placement in a Patient with a Prosthetic Tricuspid Valve. J Innov Card Rhythm Manag 2017; 8:2894-2897. [PMID: 32494432 PMCID: PMC7252841 DOI: 10.19102/icrm.2017.081103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2017] [Accepted: 08/12/2017] [Indexed: 11/16/2022] Open
Abstract
As the placement of transvenous leads across a prosthetic tricuspid valve is preferentially avoided, one must consider alternative solutions to provide necessary pacing and/or defibrillator therapy. Here, we present a case of novel placement of an implantable cardioverter-defibrillator (ICD) lead in the right atrium, in order to provide safe ICD therapy in a patient with a prosthetic tricuspid valve.
Collapse
Affiliation(s)
- Pratik Patel
- Division of Cardiac Electrophysiology, Rush University Medical Center, Chicago, IL, USA
| | - Kousik Krishnan
- Division of Cardiac Electrophysiology, Rush University Medical Center, Chicago, IL, USA
| | - Sandeep Saha
- Division of Cardiac Electrophysiology, Rush University Medical Center, Chicago, IL, USA
| | - Richard G Trohman
- Division of Cardiac Electrophysiology, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
3
|
Kim JW, Hwang GS, Seo KW, Park JS, Yang HM, Lim HS, Choi BJ, Choi SY, Yoon MH, Tahk SJ. Anatomical Discrepancy Between The Coronary Sinus and the Mitral Annulus by Fluoroscopy. INTERNATIONAL JOURNAL OF ARRHYTHMIA 2016. [DOI: 10.18501/arrhythmia.2016.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
4
|
Chan NY. Catheter ablation of peri-nodal and pulmonary veno-atrial substrates: should it be cool? Europace 2016; 17 Suppl 2:ii19-30. [DOI: 10.1093/europace/euv230] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
|
5
|
Katsouras G, Dubuc M, Khairy P. Transcatheter mapping and ablation of arrhythmias in the coronary sinus. Expert Rev Cardiovasc Ther 2014; 4:711-20. [PMID: 17081093 DOI: 10.1586/14779072.4.5.711] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The coronary sinus (CS) is a complex structure of particular interest to cardiac electrophysiologists. It is exploited as an anatomical reference, a site to record left-sided atrial and ventricular signals and for cardiac resynchronization therapy. Perhaps less appreciated, it may itself serve as a substrate for arrhythmias. It is now increasingly recognized that arrhythmias may be targeted by transcatheter ablation within the CS. This review summarizes pertinent anatomic considerations, explores the relationship between the CS and various arrhythmia substrates, elaborates on current indications for intra CS ablation and addresses efficacy and safety concerns associated with transcatheter ablation.
Collapse
Affiliation(s)
- Grigorios Katsouras
- Montreal Heart Institute, Electrophysiology and Adult Congenital Heart Disease, 5000 Belanger St E., Montreal, QC H1T 1C8, Canada
| | | | | |
Collapse
|
6
|
Radiofrequency ablation of coronary sinus-dependent atrial flutter guided by fractionated mid-diastolic coronary sinus potentials. J Interv Card Electrophysiol 2010; 29:97-107. [PMID: 20814733 PMCID: PMC2949572 DOI: 10.1007/s10840-010-9504-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2010] [Accepted: 06/20/2010] [Indexed: 11/12/2022]
Abstract
Background The efficacy of radiofrequency (RF) ablation of an uncommon coronary sinus (CS)-dependent atrial flutter (AFL) was evaluated using conventional electrophysiological criteria in a highly selected subset of patients with typical and atypical AFL. Methods Fourteen patients with atrial flutter (11 males, mean age 69 ± 9 years) without previous right or left atrial RF ablation were included. Heart disease was present in eight patients. Baseline ECG suggested typical AFL in 12 patients and atypical AFL in two. Mean AFL cycle length was 324 ± 64 ms at the time of RF ablation in the CS. Lateral right atrium activation was counterclockwise (CCW) in 13 patients and clockwise in one. CS activation was CCW in all. Criteria for CS ablation included the presence of CS mid-diastolic fractionated atrial potentials (APs) associated with concealed entrainment with a postpacing interval within 20 ms. Success was defined as termination of AFL and subsequent noninducibility. Results The initial target for ablation was the cavotricuspid isthmus (CTI) in 11 patients and the CS with further CTI ablation in three. AP duration at the CS target site was 122 ± 33 ms, spanning 40 ± 12% of the AFL cycle length. CS ablation site was located 1–4 cm from the CS ostium. Ablation was successful in all patients. Mean time to AFL termination during CS ablation was 39 ± 52 s (<20 s in eight patients). No recurrence of ablated arrhythmia occurred during a follow-up of 18 ± 8 months. Conclusions The CS musculature is a critical part of some AFL circuits in patients with typical and atypical AFL. AFL can be terminated in patients with CS or CTI/CS AFL reentrant circuits by targeting CS mid-diastolic fragmented APs.
Collapse
|
7
|
JAZAYERI MOHAMMADR, TCHOU PATRICK, CACERES JOSE, MCKINNIE JAMES, AVITALL BOAZ, GILBERT CAROL, WERNER PAUL, AKHTAR MASOOD. Ventriculoatrial Conduction Time During Bundle Branch Reentrant Beat Initiating Orthodromic Tachycardia: A Simple and Reliable Method for Localization of Accessory Pathways. J Cardiovasc Electrophysiol 2008. [DOI: 10.1111/j.1540-8167.1990.tb01054.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
8
|
GROGAN EWAYNE, NELLIS STEPHENH, SUBRAMANIAN RAMIAH. Catheter Ablation of Ventricular Endocardium Using Radiofrequency Energy: Determinants of Lesion Volume and Shape. ACTA ACUST UNITED AC 2008. [DOI: 10.1111/j.1540-8167.1989.tb01560.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
9
|
De Sisti A, Tonet J, Marrakchi S, Raguin D, Frank R. Effective cryoablation of a lateral accessory pathway within the distal coronary sinus. J Interv Card Electrophysiol 2008; 22:189-93. [DOI: 10.1007/s10840-008-9273-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2007] [Accepted: 04/24/2008] [Indexed: 10/22/2022]
|
10
|
KHAIRY PAUL, DUBUC MARC. Transcatheter Cryoablation Part I: Preclinical Experience. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007; 31:112-20. [DOI: 10.1111/j.1540-8159.2007.00934.x] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
11
|
Fenelon G, Franco M, Arfelli E, Okada M, De Araújo S, De Paola AAV. Acute and Chronic Effects of Extensive Radiofrequency Lesions in the Canine Caval Veins: Implications for Ablation of Atrial Arrhythmias. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 29:1387-94. [PMID: 17201847 DOI: 10.1111/j.1540-8159.2006.00552.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Although radiofrequency (RF) ablation within the caval veins has been increasingly used to treat a variety of atrial tachyarrhythmias, the consequences of RF ablation in the caval veins are unknown. We explored the acute and chronic angiographic and pathological effects of extensive RF ablation in the caval veins. METHODS Under fluoroscopy guidance, conventional (4 mm tip, 60 degrees C, 60 seconds) RF applications (n = 6-7) were delivered in each vena cava (from +/-2 cm into the vein to the veno-atrial junction) of 15 dogs (10 +/- 3 kg). Animals were killed 1 hour and 5 weeks after ablation for histological analysis. Angiography was performed before ablation (acute dogs only) and at sacrifice to assess the degree of vascular stenosis. RESULTS In acute dogs (n = 5), luminal narrowing was noted in 10/10 (100%) targeted veins (mild in two; moderate in three and severe in five, including two total occlusions). In the six chronic animals that completed the protocol (four died during follow-up), stenosis was also observed in 12/12 (100%) ablated veins (mild in six; moderate in four and severe in two). Of these, one superior vena cava was suboccluded with development of extensive collateral circulation. Histologically, acute lesions displayed typical transmural coagulative necrosis, whereas chronic lesions revealed intimal proliferation, necrotic muscle replaced with collagen, endovascular contraction, and disruption and thickening of the internal elastic lamina. CONCLUSION In this model, extensive RF ablation in the caval veins may result in significant vascular stenosis. These findings may have implications for catheter ablation of arrhythmias originating within the caval veins.
Collapse
Affiliation(s)
- Guilherme Fenelon
- Department of Cardiology, Paulista School of Medicine, Federal University if São Paulo, São Paulo, SP, Brazil.
| | | | | | | | | | | |
Collapse
|
12
|
Affiliation(s)
- Risa M Roland
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, NY 14853, USA
| | | |
Collapse
|
13
|
Meininger GR, Berger RD. Idiopathic ventricular tachycardia originating in the great cardiac vein. Heart Rhythm 2006; 3:464-6. [PMID: 16567296 DOI: 10.1016/j.hrthm.2005.12.021] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2005] [Accepted: 12/23/2005] [Indexed: 11/21/2022]
Affiliation(s)
- Glenn R Meininger
- Department of Medicine, Division of Cardiology, The Johns Hopkins University School of Medicine, Baltimore, Maryland 21287, USA
| | | |
Collapse
|
14
|
Peng J, Madrid AH, Palmeiro A, Rebollo JMG, Limón L, Nannini S, Marín I, Bernal E, Escobar C, Viana M, Moro C. Saline Irrigated Catheter Ablation for Pulmonary Vein Isolation in Pigs:. An Experimental Model. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2004; 27:495-501. [PMID: 15078404 DOI: 10.1111/j.1540-8159.2004.00470.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Focal AF is amenable to radical cure by RF ablation within the PV. The primary purpose of this study was to compare lesion characteristics for irrigated versus standard ablation using three power settings for PV isolation in pigs. Secondary analyses were the comparisons of ablation time and temperature characteristics, and evaluation of short-term safety in the pig model. In 20 pigs from 25 to 35 kg in weight, transseptal catheterization was performed and then the ablation catheter was advanced into the PV. RF energy was delivered to the ostium of the PV until its isolation was achieved. The animals were euthanized 1 week after ablation for pathological examination. Electrophysiological isolation of the PV was achieved, although it was difficult to achieve a complete circumferencial lesion in the ostium of the PV. Both of these catheters can produce transmural necrosis, even using 15 W of power. The authors did not see any stenosis of the PV. This might be due to the low energy delivery and the short follow-up. Pulmonary hemorrhage was present in two animals with 50 W of power, high energy output is dangerous for the ablation of the PV.
Collapse
Affiliation(s)
- Jian Peng
- Arrhythmia Unit, Ramón y Cajal Hospital, Department of Medicine, Alcalá University, Madrid, Spain
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Van Gelder BM, Meijer A, Basting P, Hendrix G, Bracke FA. Successful implantation of a coronary sinus lead after stenting of a coronary vein stenosis. Pacing Clin Electrophysiol 2003; 26:1904-6. [PMID: 12930509 DOI: 10.1046/j.1460-9592.2003.00289.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Dislodgment of the coronary sinus lead was observed in a 79-year-old patient 8 months after implantation of a biventricular pacing system. A severe stenosis in the posterolateral branch, in which the lead was previously positioned, prohibited reinsertion of the lead. Because no other branches with adequate anatomy for lead insertion were available in the targeted area, the stenosis was dilated and stented. Subsequently, the left ventricular lead could be reimplanted in the same vessel.
Collapse
Affiliation(s)
- Berry M Van Gelder
- Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands.
| | | | | | | | | |
Collapse
|
16
|
Taylor GW, Kay GN, Zheng X, Bishop S, Ideker RE. Pathological effects of extensive radiofrequency energy applications in the pulmonary veins in dogs. Circulation 2000; 101:1736-42. [PMID: 10758058 DOI: 10.1161/01.cir.101.14.1736] [Citation(s) in RCA: 147] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
INTRODUCTION The long-term complications of catheter ablation within the pulmonary veins are unknown. The development of pulmonary vein stenosis has recently been described after catheter ablation to treat either chronic or paroxysmal atrial fibrillation. The purpose of this study was to examine the pathological and hemodynamic effects of radiofrequency (RF) energy application within the pulmonary veins. METHODS AND RESULTS Right heart and transseptal catheterization were performed in 9 anesthetized mongrel dogs. The pulmonary vein ostia were cannulated and pulmonary venous pressure was measured before RF energy application in up to 4 separate pulmonary veins. Animals were euthanized at intervals of 2 to 4 weeks (n=3), 6 to 8 weeks (n=3), or 10 to 14 weeks (n=3) after ablation. Repeat catheterization before euthanasia demonstrated statistically significant differences in pulmonary capillary wedge pressure, cardiac output, pulmonary vascular resistance, and systemic vascular resistance (P<0.05) compared with the baseline. Luminal narrowing was observed in 22 of 33 pulmonary veins to which RF energy was applied. Of these, 7 were totally occluded, 7 had severe stenosis, and 8 were only minimally narrowed. Histological examination revealed intimal proliferation with organizing thrombus, necrotic myocardium in various stages of collagen replacement, endovascular contraction, and a proliferation of elastic lamina. CONCLUSIONS Applications of RF current within the pulmonary veins may result in pulmonary vein narrowing or complete occlusion. These observations should be considered in treatment of arrhythmias originating within the pulmonary veins.
Collapse
Affiliation(s)
- G W Taylor
- Department of Medicine, Division of Cardiovascular Diseases, University of Alabama at Birmingham, 35294-0019, USA
| | | | | | | | | |
Collapse
|
17
|
Dorbala S, Cohen AJ, Hutchinson LA, Menchavez-Tan E, Steinberg JS. Does radiofrequency ablation induce a prethrombotic state? Analysis of coagulation system activation and comparison to electrophysiologic study. J Cardiovasc Electrophysiol 1998; 9:1152-60. [PMID: 9835258 DOI: 10.1111/j.1540-8167.1998.tb00086.x] [Citation(s) in RCA: 48] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Although thromboembolism is an uncommon complication of radiofrequency (RF) ablation, some preliminary reports have suggested that RF ablation results in activation of the coagulation system, possibly increasing this risk. We hypothesized that the insertion of intravenous catheters and their prolonged intravenous placement rather than RF ablation activates the coagulation cascade. METHODS AND RESULTS Thirty-seven patients, group 1 (n = 21) during RF ablation, and group 2 (n = 16) during routine electrophysiologic studies (EPS), were studied prospectively. Blood was drawn for coagulation and fibrinolytic studies following insertion of venous sheaths (T0), following catheter placement (T1), and 1 hour after completion of RF ablation or EPS (T2). Conversion of prothrombin to thrombin was measured using thrombin-antithrombin complex (TAT) and prothrombin activation peptide (F1+2), and fibrinolytic activity was assessed using D-dimer concentration. Levels of D-dimer increased in group 1 from 823.52+/-323.52 ng/mL at T0 to 1,314.28+/-297.63 ng/mL at T2 (P = 0.005), and in group 2 from 658.15+/-161.70 ng/mL at T0 to 1625+/-641.45 ng/mL at T2 (P = 0.064). TAT levels increased from to 27.74+/-5.6 microg/L at T0 to 52.99+/-5.93 microg/L at T2 in group 1 (P = 0.09), and from 19.79+/-5.14 microg/L at T0 to 73.5+/-24.15 microg/L at T2 in group 2 (P = 0.05). F1+2 concentration increased from 1.52+/-0.30 nmol/L at T0 to 3.06+/-0.41 nmol/L at T2 in group 1 (P = 0.004), and from 1.32+/-0.30 nmol/L at T0 to 3.11+/-0.46 nmol/L at T2 in group 2 (P = 0.087). There was no significant difference in the concentration of the three coagulation variables between group 1 and group 2 at any given time point. No correlation was demonstrable between concentration of D-dimers, TAT, or F1+2 and variables of RF delivery such as cumulative energy, number of RF energy applications, or number of impedance rises. However, a significant positive correlation (r = 0.65, P<0.01) was noted between the duration of the RF ablation procedure and the concentration of D-dimers. CONCLUSION We conclude that activation of the coagulation cascade in RF ablation procedures is not related to the delivery of RF energy, but is related to the placement of intravascular catheters and to the duration of the ablation procedure.
Collapse
Affiliation(s)
- S Dorbala
- St. Luke's-Roosevelt Hospital Center and Columbia University College of Physicians and Surgeons, New York, New York 10025, USA
| | | | | | | | | |
Collapse
|
18
|
Fram DB, Berns E, Aretz T, Gillam LD, Mikan JS, Waters D, McKay RG. Feasibility of radiofrequency powered, thermal balloon ablation of atrioventricular bypass tracts via the coronary sinus: in vivo canine studies. Pacing Clin Electrophysiol 1995; 18:1518-30. [PMID: 7479173 DOI: 10.1111/j.1540-8159.1995.tb06738.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Radiofrequency catheter ablation of left-sided accessory pathways is technically demanding and usually requires left heart catheterization. The feasibility of creating lesions from within the coronary sinus of sufficient size to ablate accessory pathways in humans using a thermal balloon catheter was studied in 20 dogs. In group 1 (n = 14), 17 thermal inflations were performed in 12 dogs at either 70 degrees, 80 degrees, or 90 degrees C each for 30 or 60 seconds (in 2 dogs two non-thermal control inflations were performed). Animals were sacrificed 6.3 +/- 1.6 days later. In group 2 (n = 6), seven thermal inflations were performed at 90 degrees C each for 180, 300, or 360 seconds. Group 2 animals received antiplatelet and anticoagulant therapy for 1 week and were sacrificed at 13 +/- 10.7 days. In both groups, hemodynamic, angiographic, and electrocardiographic studies were performed at baseline, 1 hour after inflation, and prior to sacrifice. All dogs remained clinically stable throughout the procedure and no complications were attributed to the effect of thermal inflation. Thermal lesions measured 14.4 +/- 4.4 mm in length and extended from the coronary sinus intima to a mean depth of 2.9 +/- 1.2 mm (range 1.4-6.5 mm). Group 2 lesions were significantly deeper than group 1 lesions (P = 0.03). Of the 24 thermal lesions created, atrial necrosis was present in 23 and ventricular necrosis in 11. In all lesions there was some degree of either atrial necrosis, ventricular necrosis, or both. A variable degree of coronary sinus thrombus was present in 18 dogs without clinical sequelae. It is concluded that radiofrequency balloon heating via the coronary sinus can create thermal lesions in the atrioventricular sulcus of dogs that may be of sufficient size to ablate accessory left-sided pathways in humans.
Collapse
Affiliation(s)
- D B Fram
- Department of Internal Medicine, Hartford Hospital, University of Connecticut 06102, USA
| | | | | | | | | | | | | |
Collapse
|
19
|
Saul JP, Hulse JE, Papagiannis J, Van Praagh R, Walsh EP. Late enlargement of radiofrequency lesions in infant lambs. Implications for ablation procedures in small children. Circulation 1994; 90:492-9. [PMID: 8026036 DOI: 10.1161/01.cir.90.1.492] [Citation(s) in RCA: 143] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
BACKGROUND Despite the current clinical use of radiofrequency (RF) catheter ablation in infants, the acute and late effects of RF lesion production in immature myocardium remain unknown. This study was specifically designed to investigate the pathology of RF lesions in developing sheep myocardium. METHODS AND RESULTS In study 1, RF lesions were made on the epicardial left ventricular surface of the beating heart in 15 sheep, 5 approximately 4 weeks of age (11.0 +/- 1.0 kg) and 10 approximately 8 weeks of age (23.8 +/- 3.4 kg), to assess the effects of RF application duration (10 to 90 seconds) and electrode tip temperature (45 degrees to 90 degrees C) on lesion size in immature myocardium. Lesion width and depth increased asymptotically with RF duration, to 7.0 +/- 0.7 and 4.8 +/- 1.0 mm at 90 seconds, respectively. The time to reach one-half lesion size was 6.5 seconds for width and 12.0 seconds for depth. Lesion width increased nearly linearly with tip temperature above 50 degrees C, but depth followed a sigmoid relation, with no increase above 80 degrees C. In study 2, RF lesions were made in all four cardiac chambers under fluoroscopic guidance in 19 infant sheep (10.9 +/- 1.4 kg). Lesion sizes and histological characteristics were assessed acutely (acute, n = 5), at 1.07 +/- 0.02 months (1 month, n = 5), and at 8.5 +/- 0.5 months (late, n = 9). Atrial and ventricular lesions but not atrioventricular groove lesions apparently increased in size during the follow-up period. Atrial lesions width increased from 5.3 +/- 0.5 to 8.7 +/- 0.7 mm at 1 month (164%) but did not increase further at late follow-up, while ventricular lesion width increased from 5.9 +/- 0.8 to 10.1 +/- 0.7 mm (171%) at late follow-up but was not significantly changed at 1 month. Histological evaluation revealed replacement of normal myocytes with fibrous and elastic tissue at 1 month and late follow-up in all locations but also demonstrated a poorly delineated border with multiple extensions of fibrous and elastic tissue into surrounding normal myocardium in late ventricular lesions. CONCLUSIONS RF lesion formation in immature sheep myocardium is similar to that in adult myocardium acutely but is associated with late lesion enlargement and fibrous tissue invasion of normal myocardium. These findings may have implications for clinical RF ablation procedures in infants.
Collapse
Affiliation(s)
- J P Saul
- Children's Hospital, Department of Cardiology, Boston, MA 02115
| | | | | | | | | |
Collapse
|
20
|
Lemery R, Talajic M, Roy D, Lavoie L, Coutu B, Hii JT, Radzik D, Lavallee E, Cartier R. Results of a comparative study of low energy direct current with radiofrequency ablation in patients with the Wolff-Parkinson-White syndrome. BRITISH HEART JOURNAL 1993; 70:580-4. [PMID: 8280531 PMCID: PMC1025398 DOI: 10.1136/hrt.70.6.580] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE To compare two new power sources for catheter ablation in patients with the Wolff-Parkinson-White syndrome. DESIGN 120 consecutive patients with accessory pathways had catheter ablation. Low energy direct current (DC) was used in the first 60 patients and radio-frequency current in the next 60 patients. SETTING Electrophysiological laboratory of a large heart institute. PATIENTS 72 men and 48 women (mean (SD) age 35 (14) years (range 9-75)). The accessory pathways were in the left free wall in 73 patients. They were posteroseptal in 35 patients, in the right free wall in five, and anteroseptal in seven. There was no significant difference in the clinical or electrophysiological variables between the two ablation groups. RESULTS Catheter ablation with low energy direct current was successful in 55/60 patients (92%) and radiofrequency energy was successful in 52/60 patients (87%). Low energy direct current was also successful in four of the eight patients in whom radiofrequency ablation had failed. Radiofrequency ablation was successful in two of the five patients in whom low energy direct current ablation had failed. The mean (SD) procedure and fluoroscopy times for successful ablation were 3.2 (1.5) h and 61 (40) min respectively. These times were similar for both power sources. Accessory pathway conduction recurred in 17 patients (28%) who had low energy direct current and four patients (7%) who received radiofrequency energy (p < 0.004). All patients with recurrence of an accessory pathway had successful re-ablation. CONCLUSIONS Both new power sources successfully ablated accessory pathways, (overall success rate 94% (113/120 patients)). Radiofrequency ablation, however, did not require general anaesthesia and was associated with a significantly lower rate of recurrence of accessory pathway conduction. Therefore radiofrequency should be used initially for ablation. Low energy direct current may be most useful as a back-up in patients in whom radiofrequency ablation fails.
Collapse
Affiliation(s)
- R Lemery
- Department of Medicine, Montreal Heart Institute, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
21
|
Katritsis D, Heald S, Bashir Y, Ward D, Rowland E. Low-energy ablation of accessory pathways in cases for which the radiofrequency approach had failed. Am J Cardiol 1993; 72:1211-2. [PMID: 8237820 DOI: 10.1016/0002-9149(93)91000-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- D Katritsis
- Department of Cardiological Sciences, St. George's Hospital Medical School, London, United Kingdom
| | | | | | | | | |
Collapse
|
22
|
Langberg JJ, Man KC, Vorperian VR, Williamson B, Kalbfleisch SJ, Strickberger SA, Hummel JD, Morady F. Recognition and catheter ablation of subepicardial accessory pathways. J Am Coll Cardiol 1993; 22:1100-4. [PMID: 8409047 DOI: 10.1016/0735-1097(93)90422-w] [Citation(s) in RCA: 51] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVES The purpose of this study was to characterize left-sided accessory pathways that traverse the atrioventricular (AV) groove subepicardially and to describe results of radiofrequency catheter ablation within the coronary sinus in the patients studied. BACKGROUND Radiofrequency catheter ablation has proved to be a safe and effective method for treatment of accessory pathways; however, subepicardial accessory pathways may account for some of the failures encountered during endocardial ablation. METHODS The study group comprised 51 consecutive patients with a left-sided accessory pathway who were undergoing radio-frequency catheter ablation. Initially, the ablation catheter was introduced into a femoral artery and positioned on the ventricular aspect of the mitral annulus. If this endocardial approach was unsuccessful, the ablation catheter was introduced into the coronary sinus and energy applied at sites with shorter activation times than those recorded from the endocardium. RESULTS Five (10%) of 51 patients with a left-sided accessory pathway could not have accessory pathway conduction interrupted with a median of 18 endocardial radiofrequency energy applications. Accessory pathway potentials were less frequent during endocardial mapping in these 5 patients than in the 46 patients whose accessory pathway was successfully ablated from the endocardial surface. All five of these patients later had successful ablation using one or two applications of radiofrequency energy from within the coronary sinus. Effective target site electrograms in the coronary sinus were characterized by an accessory pathway potential that was larger than the corresponding atrial or ventricular electrogram. There were no complications or recurrences after ablation within the coronary sinus. CONCLUSIONS Some left-sided accessory pathways may be difficult to ablate from the endocardial surface because they traverse the AV groove subepicardially. The absence of an accessory pathway potential during endocardial mapping in combination with a relatively large accessory pathway potential within the coronary sinus may be a useful marker of a subepicardial pathway. In this select group of patients, radiofrequency catheter ablation from within the coronary sinus appears to enhance efficacy.
Collapse
Affiliation(s)
- J J Langberg
- Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Chiang CE, Chen SA, Tsang WP, Hsia CP, Wang DC, Chiou CW, Yang CR, Wang SP, Chiang BN, Chang MS. Radiofrequency ablation of left-sided accessory atrioventricular pathways in patients with unusual coronary sinus. Pacing Clin Electrophysiol 1993; 16:62-9. [PMID: 7681177 DOI: 10.1111/j.1540-8159.1993.tb01536.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
Four patients with left-sided accessory pathways (APs) and unusual coronary sinus (CS) received radiofrequency ablation. Unusual CS included occlusion of CS (patient 1), acute angulation of proximal CS (patients 2 and 3), and narrowing of CS orifice and proximal segment (patient 4). CS catheterization and AP mapping along the CS could not be performed in the four patients. Radiofrequency ablation by left ventricular retrograde technique for the manifest left posteroseptal AP (patient 1), concealed left posterior AP (patient 2), and transseptal left atrial technique for the manifest left posteroseptal AP (patient 3) and manifest left posterior AP (patient 4) were performed successfully without CS catheter guidance. This study suggests that radiofrequency ablation of left-sided AP with unusual CS is feasible by some special techniques.
Collapse
Affiliation(s)
- C E Chiang
- Department of Medicine, National Yang-Ming Medical College, Taipei, Taiwan, Republic of China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Wonnell TL, Stauffer PR, Langberg JJ. Evaluation of microwave and radio frequency catheter ablation in a myocardium-equivalent phantom model. IEEE Trans Biomed Eng 1992; 39:1086-95. [PMID: 1452175 DOI: 10.1109/10.161341] [Citation(s) in RCA: 70] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A highly localized burst of energy applied to the myocardium via a transvenous catheter-mounted power source can be used to destroy endocardial tissue regions which mediate life-threatening arrhythmias. In the past, high-voltage direct current pulses, radio-frequency (RF) current, and laser light have been used as energy sources. In this paper, the use of 2450 MHz microwave energy applied via a miniature coaxial cable-mounted helical coil antenna designed specifically for this application was investigated as a means to increase the treated volume of cardiac tissue in a controllable and efficient manner during ablation. Using an array of fiber optic temperature probes implanted in a saline-perfused, tissue-equivalent gel phantom model designed to simulate the myocardium during ablation, the heating pattern from the microwave antenna was characterized and compared to that induced by a commercial RF electrode catheter at 550 kHz. Effects of variable contact angle between the heat source and heart wall were assessed in terms of the radial penetration and overall volume of heated tissue. Heating patterns from the RF electrodes dropped off much more abruptly both radially and axially than the microwave antenna such that the volume of effectively heated tissue was more than ten times larger for the microwave antenna when the heat sources were well-coupled to the tissue, and more than four times larger for the microwave antenna when the sources were angled 30 degrees away from the tissue surface.
Collapse
Affiliation(s)
- T L Wonnell
- Joint Graduate Group in Bioengineering, University of California, Berkeley
| | | | | |
Collapse
|
25
|
Oeff M, Langberg JJ, Chin MC, Finkbeiner WE, Scheinman MM. Ablation of ventricular tachycardia using multiple sequential transcatheter application of radiofrequency energy. Pacing Clin Electrophysiol 1992; 15:1167-76. [PMID: 1381085 DOI: 10.1111/j.1540-8159.1992.tb03120.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Multiple sequential radiofrequency energy was applied in the left and right ventricles of 24 dogs to produce large ablated areas limited to endocardial and subendocardial regions. Endocardial ablation was performed in nine dogs with normal ventricles and 15 that had survived remote myocardial infarcts, three with inducible sustained monomorphic ventricular tachycardia. A quadripolar catheter was positioned either at the site of earliest ventricular activation during induced monomorphic ventricular tachycardia or at circumscribed areas of the left ventricle. Radiofrequency energy was delivered between two adjacent poles of the catheter, successively applying radiofrequency energy to the distal, middle, and proximal electrode pairs; this was repeated 9 to 11 times with the catheter in a slightly different position. A cumulative energy of 9,688 +/- 4,191 joules resulted in an ablated endocardial/subendocardial surface area of 4.7 +/- 2.2 cm2 (range 2.4-10 cm2, maximum depth 4 mm). Sustained tachycardia was not inducible by aggressive programmed ventricular stimulation in the dogs with previously inducible tachycardia, indicating successful ablation of the tachycardia foci. Only seven normal dogs were available for electrophysiological studies; three were used in acute and four in chronic studies. Ventricular tachycardia was not induced in the remaining dogs either before or after radiofrequency ablation, indicating the lack of an arrhythmogenic effect of this method. Histologic examination was performed in all nine normal dogs (five were sacrificed for acute pathological examination) as well as in the 15 with myocardial infarction. The late pathological examination of the radiofrequency lesion in these 19 animals showed homogeneous areas of coagulation necrosis and endocardial proliferation. Thus, this modified technique of radiofrequency ablation produced large homogeneous endocardial/subendocardial scars suitable for treating ventricular tachycardia and showed no evidence of an arrhythmogenic influence.
Collapse
Affiliation(s)
- M Oeff
- Department of Medicine, University of California San Francisco
| | | | | | | | | |
Collapse
|
26
|
Affiliation(s)
- D E Haines
- Department of Medicine, University of Virginia Health Sciences Center, Charlottesville
| | | |
Collapse
|
27
|
Lesh MD, Van Hare GF, Schamp DJ, Chien W, Lee MA, Griffin JC, Langberg JJ, Cohen TJ, Lurie KG, Scheinman MM. Curative percutaneous catheter ablation using radiofrequency energy for accessory pathways in all locations: results in 100 consecutive patients. J Am Coll Cardiol 1992; 19:1303-9. [PMID: 1564231 DOI: 10.1016/0735-1097(92)90338-n] [Citation(s) in RCA: 244] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Patients with accessory pathway-mediated supraventricular tachycardia have typically been treated with drugs or surgery. Although catheter ablation using high voltage direct current shocks has been used to treat patients with drug-refractory supraventricular tachycardia, there are associated disadvantages, including damage due to barotrauma as well as the need for general anesthesia. Recently, transcatheter radiofrequency energy has evolved as an alternative to direct current shock or surgery to ablate accessory pathways. Percutaneous catheter ablation of 109 accessory pathways with use of radiofrequency energy was attempted in 100 consecutive patients. Patient age ranged from 3 to 67 years. The patients had been treated for recurrent tachycardia with a mean of 2.7 +/- 0.2 antiarrhythmic agents that either proved ineffective or caused unacceptable side effects. In seven patients previous attempts at accessory pathway ablation with use of direct current shock had been unsuccessful. Forty-five (41%) of the pathways were left free wall, 43 (40%) were septal and 21 (19%) were right free wall. Eighty-nine (89%) of the 100 patients had successful radiofrequency ablation at the time of hospital discharge. In all but 12 patients the ablation was accomplished in a single session. Complications attributable to the procedure, but not to the ablation itself, occurred in four patients (4%). No patient developed atrioventricular block or other cardiac arrhythmias. Over a mean follow-up period of 10 months, nine patients had some return of accessory pathway conduction; a repeat ablation procedure was successful in all five patients in whom it was attempted. It is concluded that a catheter ablation procedure using radiofrequency energy can be performed on accessory pathways in all locations. The procedure is effective and safer, less costly and more convenient than cardiac surgery and can be considered as an alternative to lifelong medical therapy in any patient with symptomatic accessory pathway-mediated tachycardia.
Collapse
Affiliation(s)
- M D Lesh
- Department of Medicine, Unviersity of Caloifornia, San Francisco 94143
| | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Lemery R, Talajic M, Roy D, Coutu B, Lavoie L, Lavallée E, Cartier R. Success, safety, and late electrophysiological outcome of low-energy direct-current ablation in patients with the Wolff-Parkinson-White syndrome. Circulation 1992; 85:957-62. [PMID: 1537132 DOI: 10.1161/01.cir.85.3.957] [Citation(s) in RCA: 22] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
BACKGROUND Percutaneous ablation of accessory pathways with the use of a defibrillator can be accomplished with high-energy direct-current (DC) shocks of 150-400 J, but complications include cardiac tamponade and sudden cardiac death, mostly resulting from significant electrical arcing and barotrauma. A new low-energy DC power source with a brief time-constant capacitive discharge delivers shocks of 2-40 J and eliminates or greatly reduces arcing. This report describes our initial experience with this device in 60 consecutive patients (mean age, 34 years; range, 9-67 years) with Wolff-Parkinson-White syndrome. Accessory pathways were located in the left free wall in 36 patients, in the right free wall in two, were posteroseptal in 18, and anteroseptal in four. Most patients (77%) had their initial diagnostic electrophysiological study and catheter ablation during the same session. METHODS AND RESULTS Selective ablation of accessory pathways was successful in 55 patients (92%). The mean cumulative energy was 312 +/- 284 J and the mean creatine kinase MB peak (normal, 0-30 units) was 42 +/- 27 units. Patients with left free wall accessory pathways required less procedure time for ablation (2.7 +/- 0.8 versus 3.6 +/- 1.5 hours, p less than 0.0007) and less fluoroscopy time (46 +/- 24 versus 66 +/- 33 minutes, p less than 0.002). Complications were limited to transient pericarditis (three patients), one iliac artery dissection, and cardiac tamponade probably caused by catheter repositioning in the coronary sinus (one patient). An electrophysiological study was repeated in 50 of the 55 successful cases at a mean of 9 +/- 5 months. This study was normal in 48 of 50 (96%) patients. CONCLUSIONS Low-energy DC ablation is safe and effective treatment for accessory pathways in children and adults. The long-term outcome is excellent as documented by electrophysiological restudy.
Collapse
Affiliation(s)
- R Lemery
- Department of Medicine, Montreal Heart Institute, Canada
| | | | | | | | | | | | | |
Collapse
|
29
|
Langberg JJ, Wonnell T, Chin MC, Finkbeiner W, Scheinman M, Stauffer P. Catheter ablation of the atrioventricular junction using a helical microwave antenna: a novel means of coupling energy to the endocardium. Pacing Clin Electrophysiol 1991; 14:2105-13. [PMID: 1723193 DOI: 10.1111/j.1540-8159.1991.tb06481.x] [Citation(s) in RCA: 57] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Catheter ablation with either direct current defibrillator discharges or radiofrequency energy produces tissue injury via current flow from an electrode into the adjacent myocardium. In order to affect tissue at a distance, excessive power density may be produced at the electrode-tissue interface with the possibility of explosive gas formation or coagulum formation. A novel microwave catheter was developed with a helical antenna distally. This coil, although not in direct contact with the endocardium, radiates an electromagnetic field into the tissue that, in turn, causes thermal injury. The utility of this system for ablation was assessed in six dogs. The antenna catheter was introduced percutaneously and positioned so as to record the largest His electrogram. Microwave power (50 watts at 2,450 MHz) was applied for 114 +/- 118 seconds. Complete AV block was produced in all six animals with 1.8 +/- 1.2 applications. There was no ventricular ectopy or change in blood pressure during microwave ablation. One dog died 6 days after ablation. The remaining five dogs had persistent, complete AV block during 6 weeks of follow-up. Pathological analysis at 6 weeks revealed a large (mean 2.8 x 4.7 mm) fibrovascular scar in the region of the AV junction. Percutaneous microwave ablation of the endocardium appears feasible. By radiating an electromagnetic field without direct contact, this system can produce large lesions without being limited by desiccation of tissue and impedance rise.
Collapse
Affiliation(s)
- J J Langberg
- Department of Medicine, University of California, San Francisco
| | | | | | | | | | | |
Collapse
|
30
|
Scheinman MM, Laks MM, DiMarco J, Plumb V. Current role of catheter ablative procedures in patients with cardiac arrhythmias. A report for health professionals from the Subcommittee on Electrocardiography and Electrophysiology, American Heart Association. Circulation 1991; 83:2146-53. [PMID: 2040065 DOI: 10.1161/01.cir.83.6.2146] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Catheter ablative techniques have assumed an increasingly important role in the treatment of patients with drug-refractory cardiac arrhythmias. Catheter ablation of the AV junction is considered the procedure of choice for management of patients without bypass tracts with drug-resistant supraventricular arrhythmias. Catheter techniques have been used with increasing frequency in attempts to ablate accessory AV tracts. These techniques currently appear to be less effective than surgical techniques but involve less morbidity and expense. In some centers, accessory pathway ablation using catheter techniques is the procedure of first choice in selected patients with drug-refractory tachycardia mediated by an accessory pathway. Catheter ablation of ventricular tachycardia should be reserved for patients with mappable ventricular tachycardia who are not candidates for cardiac electrosurgery or insertion of an automatic defibrillator. The development of more flexible catheters and more manageable energy delivery systems holds promise for more effective catheter techniques.
Collapse
Affiliation(s)
- M M Scheinman
- Office of Scientific Affairs, American Heart Association, Dallas, TX 75231
| | | | | | | |
Collapse
|
31
|
Kay GN, Bubien RS, Dailey SM, Epstein AE, Plumb VJ. A prospective evaluation of intracoronary ethanol ablation of the atrioventricular conduction system. J Am Coll Cardiol 1991; 17:1634-40. [PMID: 2033196 DOI: 10.1016/0735-1097(91)90659-w] [Citation(s) in RCA: 29] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The clinical efficacy and complications associated with ablation of the atrioventricular (AV) conduction system by the selective infusion of ethanol into the AV node artery were prospectively assessed in 12 consecutive patients with medically refractory atrial arrhythmias. Six of the patients had previously failed to have permanent complete AV block created with direct current or radiofrequency catheter ablation. The AV node artery was cannulated with a 0.016 in. (0.041 cm) guide wire in all 12 patients. It was also possible to advance a 2.7F infusion catheter into the AV node artery in all patients. Transient AV block was induced by selective injections into the AV node artery of iced saline solution (8 patients) and of radiographic contrast agent (ioxaglate) (10 patients). The infusion of 2 ml of ethanol (96%) induced immediate complete AV block in all 10 patients who demonstrated AV block with ioxaglate. The escape rhythm exhibited a narrow QRS complex preceded by a His bundle deflection in nine patients and left bundle branch block in one patient. The immediate mean rate of the escape rhythm was 45.3 +/- 13.4 beats/min. In two patients who demonstrated reflux of contrast agent into the distal right coronary artery with selective injections into the AV node artery, transient ST segment elevation developed in the inferior electrocardiographic leads with the infusion of ethanol. There was no change in the left ventricular ejection fraction from the baseline value (0.53 +/- 0.12) to that measured after ablation (0.55 +/- 0.11) and no patient developed wall motion abnormalities.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- G N Kay
- Department of Medicine, University of Alabama, Birmingham 35294
| | | | | | | | | |
Collapse
|
32
|
|
33
|
Abstract
In the past 5 years, numerous reports have appeared of the use of radiofrequency (RF) current as an energy source for catheter ablation therapy of cardiac arrhythmias. Laboratory investigations using in vitro and in vivo animal models to study the biophysical and histologic effects as well as to assess the efficacy and safety of this technique in ablating various cardiac structures have been extensively performed and have led to successful applications in humans. Clinical experience with RF catheter ablation of the AV junction and accessory pathway has proliferated each year. However, experience with RF ablation of the VT focus remains quite limited. With further advances in catheter electrode design for mapping and ablation, a widespread application of RF catheter ablation to the treatment of cardiac arrhythmias is anticipated.
Collapse
Affiliation(s)
- S K Huang
- Department of Medicine, University of Massachusetts Medical School, Worcester
| |
Collapse
|
34
|
Lemery R, Leung TK, Lavallée E, Girard A, Talajic M, Roy D, Montpetit M. In vitro and in vivo effects within the coronary sinus of nonarcing and arcing shocks using a new system of low-energy DC ablation. Circulation 1991; 83:279-93. [PMID: 1984886 DOI: 10.1161/01.cir.83.1.279] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
DC shocks within the coronary sinus have been abandoned because of the risk of cardiac rupture and tamponade. Catheter ablation using DC energy to electrodes straddling the ostium of the coronary sinus, when used clinically, has been reported to result in cardiac tamponade in as many as 16% of patients. A new system of energy delivery maximizes voltage while decreasing the undesirable effects caused by barotrauma. This system includes 1) a low-energy ablation power supply with a brief time-constant capacitive discharge that delivers up to 40 J and 3,000 V and 2) a low-energy ablation catheter with a contoured distal electrode. We performed in vitro and in vivo studies of this new system and compared arcing shocks with nonarcing shocks. Ablations were performed using unipolar distal shocks (D) and unipolar shocks to both electrodes made electrically common (P-D). In vitro studies were done in a large tank filled with physiological saline while recording voltage, current, and pressure. High-speed cinematography (32,000 frames/sec) of shocks of 10-40 J permitted detailed analysis of the vapor globe. Anodal shocks of less than 20 J showed no arcing or only minimal vapor globe formation. For D and P-D anodal shocks of 40 J, the diameters of the vapor globe were 31 and 22 mm, respectively, corresponding to pressure recordings of 11 and 4.9 atm. The pressure rise lasted less than 50 mu sec. In vivo studies involved 18 dogs that received nonarcing shocks (one to six shocks of 15 J) and 18 dogs that received arcing shocks (one to three shocks of 40 J). Each group was divided between D and P-D shocks; catheter ablation was performed at a mean +/- SEM distance of 2.94 +/- 0.92 cm within the coronary sinus. All dogs tolerated the procedure without cardiac rupture or tamponade. When killed 2-4 days later, the dogs had edema and hyperemia or hemorrhage in the area of the coronary sinus. We compared the effects of multiple (three to six) nonarcing shocks with the effects of one to three arcing shocks. Disruption or rupture of the coronary sinus within the epicardial fat space occurred in two of 12 dogs (17%) with multiple nonarcing shocks but in 13 of 18 dogs (72%) with arcing shocks (p less than 0.003). Occlusion of the coronary sinus occurred in two of 12 dogs (17%) with multiple nonarcing shocks and in nine of 18 dogs (50%) with arcing shocks (p less than 0.06).(ABSTRACT TRUNCATED AT 400 WORDS)
Collapse
Affiliation(s)
- R Lemery
- Department of Medicine, Montreal Heart Institute, Canada
| | | | | | | | | | | | | |
Collapse
|
35
|
Langberg JJ, Lee MA, Chin MC, Rosenqvist M. Radiofrequency catheter ablation: the effect of electrode size on lesion volume in vivo. Pacing Clin Electrophysiol 1990; 13:1242-8. [PMID: 1701538 DOI: 10.1111/j.1540-8159.1990.tb02022.x] [Citation(s) in RCA: 126] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Radiofrequency current is a promising alternative to high voltage direct current defibrillator discharges for catheter ablation of arrhythmias. However, lesions produced with radiofrequency current are relatively small and use of high power is limited by the impedance rise that occurs with desiccation of tissue and coagulum formation. The effect of electrode size on radiofrequency ablation was assessed by comparing results of radiofrequency application using a standard 6 French electrode catheter (distal electrode 2 mm in length) to those using catheters modified with longer distal electrodes (3, 4, 6, 8, and 10 mm in length). Radiofrequency ablation was performed at 47 left ventricular endocardial sites in 20 anesthetized dogs. A constant power of 13.3 +/- 1.3 watts at 550 kHz was applied between the distal catheter electrode and a skin electrode until a total of 500 joules had been delivered or a rise in impedance occurred. Increasing electrode length from 2 to 4 mm more than doubled lesion volume from a mean of 143 to 326 mm3 (P = 0.025). Increasing electrode length beyond 4 mm produced progressively smaller lesions (157 mm3, 155 mm3, and 67 mm3 for 6-, 8-, and 10-mm electrode lengths, respectively). Impedance rise was significantly less likely with larger electrodes and took longer to occur. Increasing the size of electrodes used for radiofrequency ablation allows application of higher power without an impedance rise. Optimizing electrode size (3 or 4 mm in this study) results in larger lesions and may improve the effectiveness of radiofrequency ablation of arrhythmias.
Collapse
Affiliation(s)
- J J Langberg
- Department of Medicine, University of California, San Francisco 94143
| | | | | | | |
Collapse
|
36
|
Morady F. Catheter Ablation of Accessory Pathways. Cardiol Clin 1990. [DOI: 10.1016/s0733-8651(18)30356-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
37
|
Sanchis J, Chorro FJ, López-Merino V, Such L, Cerda M, Valentin V. Closed chest radiofrequency ablation of the sinoatrial node in dogs. Pacing Clin Electrophysiol 1990; 13:745-56. [PMID: 1695355 DOI: 10.1111/j.1540-8159.1990.tb02101.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
UNLABELLED Transcatheter ablation of the sinoatrial node with radiofrequency energy (0.6 MHZ, 2.5-5 watts) was performed in 10 dogs under fluoroscopic monitoring and autonomic blockade. Sinus function was previously studied in terms of cycle length, recovery time and atrial activation pattern by catheter mapping. Several discharges (8-22) were applied for variable periods of time (maximum 1 minute). Sinus tachycardia and/or sinus arrest during ablation confirmed correct catheter position. Sinus rhythm was abolished in eight dogs. The ectopic rhythm was atrial in six and AV nodal in two dogs. Ectopic atrial cycle length and recovery time were longer than the baseline sinus values: 724 +/- 321 versus 509 +/- 147, P less than 0.05; 1103 +/- 775 versus 618 +/- 151, P less than 0.05 (values in msec). The study was repeated 10-14 days later in six dogs; three maintained the same atrial rhythm, one persisted in sinus rhythm, and one dog changed from atrial to sinus rhythm, whereas another changed from sinus to atrial rhythm. Gross findings revealed transmural lesions in all dogs, without perforation. Histology in chronic dogs showed sinus cell necrosis and its replacement by granulation tissue. IN CONCLUSION sinus function may be abolished by closed chest radiofrequency ablation.
Collapse
Affiliation(s)
- J Sanchis
- Cardiology Department, Clinic University Hospital, Valencia, Spain
| | | | | | | | | | | |
Collapse
|
38
|
Borggrefe M, Hindricks G, Haverkamp W, Breithardt G. Catheter ablation using radiofrequency energy. Clin Cardiol 1990; 13:127-31. [PMID: 2407395 DOI: 10.1002/clc.4960130212] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Recently, transvenous catheter ablation using radiofrequency impulses has been applied in experimental animals as well as in humans. This review describes the biophysics, mechanisms, and tissue effects of radiofrequency alternating current. Ablation of the AV-junction has been performed in experimental studies as well as in a growing number of patients. Complete AV-block or modification of the AV conduction by RF-current application can be achieved in about 45-65% of patients. Presently about 50% of patients with rightsided accessory pathways can be successfully managed using radiofrequency impulses. Certain limitations exist using a biopolar "epi-endocardial" electrode configuration for leftsided accessory pathways. Only few studies are available concerning the use of RF ablation of ventricular tachycardia foci. As most experimental investigations were carried out in structurally nondiseased myocardium, the use of this new technique in fibrotic or scarred tissue warrants further studies. Radiofrequency catheter ablation seems to be feasible and relatively safe for the treatment of otherwise drug-refractory supraventricular arrhythmias; further studies are needed to assess the safety and efficacy in patients with drug-refractory ventricular tachyarrhythmias.
Collapse
Affiliation(s)
- M Borggrefe
- Department of Cardiology-Angiology, Medical Hospital, Westfälische Wilhelms Universität Münster, Federal Republic of Germany
| | | | | | | |
Collapse
|
39
|
Schuger CD, Steinman RT, Lehmann MH, Schuger L, Boldea D, McMath L, Spears JR. Percutaneous transcatheter laser balloon ablation from the canine coronary sinus: implications for the Wolff-Parkinson-White syndrome. Lasers Surg Med 1990; 10:140-8. [PMID: 2332999 DOI: 10.1002/lsm.1900100206] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Transcatheter direct current electrical shocks for ablation of left-sided accessory pathways in Wolff-Parkinson-White patients have led to serious complications. We report the feasibility of percutaneous transcatheter laser balloon ablation of left-sided accessory pathways from the coronary sinus using a 1,064-nm, continuous wave Nd:YAG laser triple lumen catheter with an optical fiber terminating in a cylindrical diffusing tip within a 2-cm-long, 3-mm-diameter balloon transparent to Nd:YAG laser radiation. In eight mongrel dogs (18 to 31 kg), the laser balloon catheter was positioned via an 8 French guide catheter in the distal and proximal coronary sinus. During balloon inflation, two to three consecutive laser doses of 30 W x 20 sec were applied to each site (cumulative energy, 1,200 to 1,800 J). Coronary angiography, left ventriculography, and coronary sinus injection were performed before and after laser exposure. After percutaneous transcatheter laser balloon ablation, there was no evidence of mitral regurgitation, left circumflex artery, coronary sinus obstruction, or perforation. Coagulation necrosis and/or polymorphonuclear infiltrates involving the atrioventricular groove and left atrial wall over a mean length of 17 mm were present in all eight dogs sacrificed 6 +/- 1 hr postablation. In conclusion, percutaneous transcatheter laser balloon ablation from the coronary sinus is free of immediate major complications and may be feasible for potential interruption of left-sided accessory pathways.
Collapse
Affiliation(s)
- C D Schuger
- Department of Medicine, Wayne State University/Harper Hospital, Detroit, MI 48201
| | | | | | | | | | | | | |
Collapse
|
40
|
Abstract
Since its introduction in 1985, there have been numerous reports of the use of radio-frequency (RF) current as an alternative energy source for catheter ablation. RF current (frequency range 150 kHz to 1 MHz), when delivered in bipolar mode, causes desiccation of tissue by creating a localized area of heat that results in discrete coagulation necrosis. An equivalent energy source such as direct current (DC) shock can be delivered at lower power (5 to 30 W) and lower voltage (30 to 80 V) for a longer pulse duration (10 to 60 seconds), thus eliminating barotraumatic effects. Because of its high frequency, RF current does not stimulate neuromuscular fibers, and general anesthesia during ablation is not needed. Studies in animals have shown that catheter-delivered RF energy can safely produce permanent complete or partial AV block, necrosis of atrial and ventricular myocardium adjacent to the mitral and tricuspid anuli potentially suitable for ablation of accessory pathways, and discrete lesions in the left and right ventricular myocardium. Recently, investigators from several centers have reported successful ablation of the AV junction (either complete or partial AV block) in patients with refractory supraventricular tachyarrhythmias, ablation of accessory pathways, and ablation of focal ventricular myocardium or a segment of a bundle branch in patients with drug-resistant ventricular tachycardia. Specific modification of AV conduction to cure AV nodal reentrant tachycardia has been successfully attempted. In all studies the application of RF current has not caused any serious complications.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- S K Huang
- Division of Cardiovascular Medicine, University of Massachusetts Medical Center, Worcester 01655
| |
Collapse
|