1
|
The design of X-band EPR cavity with narrow detection aperture for in vivo fingernail dosimetry after accidental exposure to ionizing radiation. Sci Rep 2021; 11:2883. [PMID: 33558592 PMCID: PMC7870891 DOI: 10.1038/s41598-021-82462-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 01/20/2021] [Indexed: 11/13/2022] Open
Abstract
For the purpose of assessing the radiation dose of the victims involved in the nuclear emergency or radiation accident, a new type of X-band EPR resonant cavity for in vivo fingernail EPR dosimetry was designed and a homemade EPR spectrometer for in vivo fingernail detection was constructed. The microwave resonant mode of the cavity was rectangular TE101, and there was a narrow aperture for fingernail detection opened on the cavity’s wall at the position of high detection sensitivity. The DPPH dot sample and the fingernail samples were measured based on the in vivo fingernail EPR spectrometer. The measurements of the DPPH dot sample verified the preliminary functional applicable of the EPR spectrometer and illustrated the microwave power and modulation response features. The fingernails after irradiation by gamma-ray were measured and the radiation-induced signal was acquired. The results indicated that the cavity and the in vivo EPR dosimeter instrument was able to detect the radiation-induced signal in irradiated fingernail, and preliminarily verified the basic function of the instrument and its potential for emergency dose estimate after a radiation accident.
Collapse
|
2
|
New developed cylindrical TM010 mode EPR cavity for X-band in vivo tooth dosimetry. PLoS One 2014; 9:e106587. [PMID: 25222483 PMCID: PMC4164439 DOI: 10.1371/journal.pone.0106587] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 07/30/2014] [Indexed: 11/20/2022] Open
Abstract
EPR tooth in vivo dosimetry is an attractive approach for initial triage after unexpected nuclear events. An X-band cylindrical TM010 mode resonant cavity was developed for in vivo tooth dosimetry and used in EPR applications for the first time. The cavity had a trapezoidal measuring aperture at the exact position of the cavity's cylindrical wall where strong microwave magnetic field H1 concentrated and weak microwave electric field E1 distributed. Theoretical calculations and simulations were used to design and optimize the cavity parameters. The cavity features were evaluated by measuring DPPH sample, intact incisor samples embed in a gum model and the rhesus monkey teeth. The results showed that the cavity worked at designed frequency and had the ability to make EPR spectroscopy in relative high sensitivity. Sufficient modulation amplitude and microwave power could be applied into the aperture. Radiation induced EPR signal could be observed remarkably from 1 Gy irradiated intact incisor within only 30 seconds, which was among the best in scan time and detection limit. The in vivo spectroscopy was also realized by acquiring the radiation induced EPR signal from teeth of rhesus monkey whose teeth was irradiated by dose of 2 Gy. The results suggested that the cavity was sensitive to meet the demand to assess doses of significant level in short time. This cavity provided a very potential option for the development of X-band in vivo dosimetry.
Collapse
|
3
|
Rana S, Chawla R, Kumar R, Singh S, Zheleva A, Dimitrova Y, Gadjeva V, Arora R, Sultana S, Sharma RK. Electron paramagnetic resonance spectroscopy in radiation research: Current status and perspectives. J Pharm Bioallied Sci 2011; 2:80-7. [PMID: 21814437 PMCID: PMC3147108 DOI: 10.4103/0975-7406.67006] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2010] [Revised: 04/29/2010] [Accepted: 05/21/2010] [Indexed: 12/21/2022] Open
Abstract
Exposure to radiation leads to a number of health-related malfunctions. Ionizing radiation is more harmful than non-ionizing radiation, as it causes both direct and indirect effects. Irradiation with ionizing radiation results in free radical-induced oxidative stress. Free radical-mediated oxidative stress has been implicated in a plethora of diseased states, including cancer, arthritis, aging, Parkinson's disease, and so on. Electron Paramagnetic Resonance (EPR) spectroscopy has various applications to measure free radicals, in radiation research. Free radicals disintegrate immediately in aqueous environment. Free radicals can be detected indirectly by the EPR spin trapping technique in which these forms stabilize the radical adduct and produce characteristic EPR spectra for specific radicals. Ionizing radiation-induced free radicals in calcified tissues, for example, teeth, bone, and fingernail, can be detected directly by EPR spectroscopy, due to their extended stability. Various applications of EPR in radiation research studies are discussed in this review.
Collapse
Affiliation(s)
- Sudha Rana
- Division of CBRN Defence, Institute of Nuclear Medicine and Allied Sciences, Brig. S. K. Mazumdar Marg, Timarpur Delhi - 110054, India
| | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Fattibene P, Callens F. EPR dosimetry with tooth enamel: A review. Appl Radiat Isot 2010; 68:2033-116. [PMID: 20599388 DOI: 10.1016/j.apradiso.2010.05.016] [Citation(s) in RCA: 123] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2010] [Accepted: 05/09/2010] [Indexed: 11/30/2022]
Abstract
When tooth enamel is exposed to ionizing radiation, radicals are formed, which can be detected using electron paramagnetic resonance (EPR) techniques. EPR dosimetry using tooth enamel is based on the (presumed) correlation between the intensity or amplitude of some of the radiation-induced signals with the dose absorbed in the enamel. In the present paper a critical review is given of this widely applied dosimetric method. The first part of the paper is fairly fundamental and deals with the main properties of tooth enamel and some of its model systems (e.g., synthetic apatites). Considerable attention is also paid to the numerous radiation-induced and native EPR signals and the radicals responsible for them. The relevant methods for EPR detection, identification and spectrum analyzing are reviewed from a general point of view. Finally, the needs for solid-state modelling and studies of the linearity of the dose response are investigated. The second part is devoted to the practical implementation of EPR dosimetry using enamel. It concerns specific problems of preparation of samples, their irradiation and spectrum acquisition. It also describes how the dosimetric signal intensity and dose can be retrieved from the EPR spectra. Special attention is paid to the energy dependence of the EPR response and to sources of uncertainties. Results of and problems encountered in international intercomparisons and epidemiological studies are also dealt with. In the final section the future of EPR dosimetry with tooth enamel is analyzed.
Collapse
Affiliation(s)
- Paola Fattibene
- Istituto Superiore di Sanità, Department of Technology and Health, Viale Regina Elena, Rome, Italy.
| | | |
Collapse
|
5
|
Swartz HM, Burke G, Coey M, Demidenko E, Dong R, Grinberg O, Hilton J, Iwasaki A, Lesniewski P, Kmiec M, Lo KM, Nicolalde RJ, Ruuge A, Sakata Y, Sucheta A, Walczak T, Williams BB, Mitchell C, Romanyukha A, Schauer DA. In Vivo EPR For Dosimetry. RADIAT MEAS 2007; 42:1075-1084. [PMID: 18591988 DOI: 10.1016/j.radmeas.2007.05.023] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
As a result of terrorism, accident, or war, populations potentially can be exposed to doses of ionizing radiation that could cause direct clinical effects within days or weeks. There is a critical need to determine the magnitude of the exposure to individuals so that those with significant risk have appropriate procedures initiated immediately, while those without a significant probability of acute effects can be reassured and removed from the need for further consideration in the medical/emergency system. In many of the plausible scenarios there is an urgent need to make the determination very soon after the event and while the subject is still present. In vivo EPR measurements of radiation-induced changes in the enamel of teeth is a method, perhaps the only such method, which can differentiate among doses sufficiently for classifying individuals into categories for treatment with sufficient accuracy to facilitate decisions on medical treatment. In its current state, the in vivo EPR dosimeter can provide estimates of absorbed dose with an error approximately +/- 50 cGy over the range of interest for acute biological effects of radiation, assuming repeated measurements of the tooth in the mouth of the subject. The time required for acquisition, the lower limit, and the precision are expected to improve, with improvements in the resonator and the algorithm for acquiring and calculating the dose. The magnet system that is currently used, while potentially deployable, is somewhat large and heavy, requiring that it be mounted on a small truck or trailer. Several smaller magnets, including an intraoral magnet are under development, which would extend the ease of use of this technique.
Collapse
Affiliation(s)
- Harold M Swartz
- Dartmouth Medical School, EPR Center for the Study of Viable Systems, Hanover, NH USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Schauer DA, Iwasaki A, Romanyukha AA, Swartz HM, Onori S. Electron paramagnetic resonance (EPR) in medical dosimetry. RADIAT MEAS 2006. [DOI: 10.1016/j.radmeas.2007.01.006] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
7
|
Swartz HM, Iwasaki A, Walczak T, Demidenko E, Salikhov I, Khan N, Lesniewski P, Thomas J, Romanyukha A, Schauer D, Starewicz P. In vivo EPR dosimetry to quantify exposures to clinically significant doses of ionising radiation. RADIATION PROTECTION DOSIMETRY 2006; 120:163-70. [PMID: 16644994 DOI: 10.1093/rpd/nci554] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
As a result of terrorism, accident or war, populations potentially can be exposed to doses of ionising radiation that could cause direct clinical effects within days or weeks. There is a critical need to determine the magnitude of the exposure to individuals so that those with significant risk can have appropriate procedures initiated immediately, while those without a significant probability of acute effects can be reassured and removed from the need for further consideration in the medical/emergency system. It is extremely unlikely that adequate dosemeters will be worn by the potential victims, and it also will be unlikely that prompt and accurate dose reconstruction at the level of individuals will be possible. Therefore, there is a critical need for a method to measure the dose from radiation-induced effects that occur within the individual. In vivo EPR measurements of radiation-induced changes in the enamel of teeth is a method, perhaps the only such method, which can differentiate among doses sufficiently to classify individuals into categories for treatment with sufficient accuracy to facilitate decisions on medical treatment. In its current state, the in vivo EPR dosemeter can provide estimates of absorbed dose of +/- 0.5 Gy in the range from 1 to >10 Gy. The lower limit and the precision are expected to improve, with improvements in the resonator and the algorithm for acquiring and calculating the dose. In its current state of development, the method is already sufficient for decision-making action for individuals with regard to acute effects from exposure to ionising radiation for most applications related to terrorism, accidents or nuclear warfare.
Collapse
Affiliation(s)
- Harold M Swartz
- EPR Center for Viable Systems, Dartmouth Medical School, 703 Vail, Hanover, NH 03755, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Swartz HM, Iwasaki A, Walczak T, Demidenko E, Salikov I, Lesniewski P, Starewicz P, Schauer D, Romanyukha A. Measurements of clinically significant doses of ionizing radiation using non-invasive in vivo EPR spectroscopy of teeth in situ. Appl Radiat Isot 2005; 62:293-9. [PMID: 15607464 DOI: 10.1016/j.apradiso.2004.08.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
There are plausible circumstances in which populations potentially have been exposed to doses of ionizing radiation that could cause direct clinical effects within days or weeks, but there is no clear knowledge as to the magnitude of the exposure to individuals. In vivo EPR is a method, perhaps the only such method that can differentiate among doses sufficiently to classify individuals into categories for treatment with sufficient accuracy to facilitate decisions on medical treatment. Individuals with significant risk then can have appropriate procedures initiated immediately, while those without a significant probability of acute effects could be reassured and removed from the need for further medical treatment. In its current state, the in vivo EPR dosimeter can provide estimates of absorbed dose of +/-25 cGy in the range of 100-->1000 cGy. This is expected to improve, with improvements in the resonator, the algorithm for calculating dose, and the uniformity of the magnetic field. In its current state of development, it probably is sufficient for most applications related to terrorism or nuclear warfare, for decision-making for action for individuals in regard to acute effects from exposure to ionizing radiation.
Collapse
Affiliation(s)
- Harold M Swartz
- Dartmouth Medical School, EPR Center for Viable Systems, Hanover, NH 03755, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Miyake M, Liu KJ, Walczak TM, Swartz HM. In vivo EPR dosimetry of accidental exposures to radiation: experimental results indicating the feasibility of practical use in human subjects. Appl Radiat Isot 2000; 52:1031-8. [PMID: 10836403 DOI: 10.1016/s0969-8043(00)00053-1] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
Low frequency electron paramagnetic resonance (EPR) provides the potential advantage of making accurate and sensitive measurements of absorbed radiation dose in teeth in situ, i.e. without removing the teeth from the potential victim. The potential limiting factors for making such measurements are: (1) whether low frequency EPR is sufficiently sensitive to detect radiation-induced signal in human teeth; (2) whether sufficient sensitivity can be maintained under in vivo conditions. In this manuscript, we summarize results indicating that this approach is feasible. Using 1.2 GHz EPR spectroscopy, we found that the lower limit for these measurements in isolated human teeth is 0.2 Gy or lower. Measurements of radiation-induced EPR signals in the teeth of living rats were achieved with sufficient sensitivity to indicate that, when taking into consideration the larger mass of human teeth, similar measurements in human teeth in situ would provide sensitivity in the dose range for potential accidental exposures. We estimate that the current lower limit for detecting radiation doses in human teeth in situ (in vivo) is 0.5-1.0 Gy; this would be sufficient for determining if a person has been exposed to potentially life threatening doses of ionizing radiation. The limiting factor for sensitivity appears to be background signals rather than signal/noise, and there are feasible means to overcome this problem and further increase sensitivity. The additional instrumental developments required to make an effective in vivo EPR dosimetric spectrometer for the measurements in teeth in human subjects in situ, seem quite achievable.
Collapse
Affiliation(s)
- M Miyake
- EPR Center for the Study of Viable Biological Systems, Dartmouth Medical School, Hanover, NH 03755, USA
| | | | | | | |
Collapse
|
10
|
Greenstock CL, Trivedi A. Biological and biophysical techniques to assess radiation exposure: a perspective. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 1994; 61:81-130. [PMID: 8029472 DOI: 10.1016/0079-6107(94)90007-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Biological dosimeters measure biologically relevant effects of radiation exposure that are in some sense an estimate of effective dose, whereas biophysical indicators serve as surrogates of absorbed dose in a manner analogous to conventional thermoluminescent dosimeters (TLD). The biological and biophysical dosimeters have the potential to play an important role in assessing unanticipated or occupational radiation exposures. For example, where the exposure is large and uncertain (i.e. radiation accidents), accurate dose information can help in deciding the most appropriate therapy and medical treatment. Another useful area is that of lifetime accumulated dose determination, and the ability to distinguish between and integrate the exposures from natural and anthropogenic (medical X-rays, indoor radon, natural background radiation, occupational and non-occupational exposures). Also, the possibility to monitor individual response and differences in inherent or induced radiation sensitivity may have important implications for radiation protection. More commonly, this type of dosimetry could be used for routine monitoring to detect and quantify unsuspected exposure, for regulatory purposes or for epidemiological studies of the long-term effects of radiation exposure (e.g. in Japanese A-bomb survivors or in the population surrounding Chernobyl). This review is a comparative study of the existing techniques and their future prospects. It summarizes the sensitivity, reproducibility, limiting dose, dose-rate, energy, LET response, sources of variability and uncertainty, and other practical aspects of each bio-indicator. The strengths and weaknesses of each approach are evaluated on the basis of common criteria for particular applications, and are summarized for each assay both in the text and in tabular form, for convenience. It is clear that no single indicator qualifies to reliably measure occupational exposures at the current levels of sensitivity conventional dosimetry services provide. Most of the bio-techniques are applicable to the detection of relatively high radiation exposures at relatively short times after exposure. Some of the bio-indicators have been identified that are, or offer future prospects for becoming, appropriate bio-indicators for dosimetry needs. However, all methods are subject to biological and other variables that are presently uncontrolled, and represent a major source of uncertainty. These include variations in background signals not directly associated with radiation exposure, inter- and intra-individual variability of radiation response, and genetic and environmental effects. Although these factors contribute to the lack of confidence in biological dosimetry, promising bio-indicators may be applied to large populations to establish the inherent variability and confounding factors that limit quantitative data collection and analysis, and reduce reliability and reproducibility.
Collapse
Affiliation(s)
- C L Greenstock
- Health Sciences and Services Division, AECL Research, Chalk River Laboratories, Ontario, Canada
| | | |
Collapse
|