1
|
Zhang S, Qu W, Chen S, Guo D, Xue K, Li R, Zhang J, Yang L. A specific visual-volumetric sensor for mercury ions based on smart hydrogel. Analyst 2023; 148:5942-5948. [PMID: 37853759 DOI: 10.1039/d3an01224g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
On the basis of the "seeing is believing" concept and the existing theory of Hg2+ coordination chemistry, for the first time, we innovatively designed and synthesized a visual-volumetric sensor platform with fluorescein and uracil functionalized polyacrylamide hydrogel. Without the aid of any complicated instruments and power sources, the sensor-enabled quantitative μM-level Hg2+ detection Hg2+ by reading graduation on a pipette with the naked eye. The sensor undergoes volumetric response and shows a wide linear response range to Hg2+ (1.0 × 10-6-5.0 × 10-5 mol L-1) with 2.8 × 10-7 mol L-1 as the detection limit. The highly selective (easily distinguished Hg2+ from other common metal ions), rapid response (∼30 min), and acceptable repeatability (RSD < 5% in all cases) demonstrated that the developed sensor is suitable for onsite practical use for the determination of Hg2+ while being low-cost, simple, and portable. The design principles of the obtained materials and the construction techniques and methods of the sensors described in our study provide a new idea for the research and development of smart materials and a series of visual-volumetric sensors for other analytes.
Collapse
Affiliation(s)
- Shenghai Zhang
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Wenzhong Qu
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Simeng Chen
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Dian Guo
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Kaixi Xue
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Run Li
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Jidong Zhang
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| | - Lingjian Yang
- School of Chemistry and Chemical Engineering, Ankang University, Quality Supervision and Inspection Centre of Se-enriched Food of Shaanxi Province, Shaanxi University Innovation Research Institute of Advanced Energy Storage Materials and Battery Technology for Future Industrialization, Ankang Research Centre of New Nano-materials Science and Technology Research Centre, Ankang, Shaanxi Province, 725000, P. R. China.
| |
Collapse
|
2
|
Qin L, Huang T, Cui H, Cheng M, Wei G, Liao F, Xiong W, Jiang H, Zhang J, Fan H. A fluorescence-electrochemiluminescence dual-mode sensor based on a "switch" system for highly selective and sensitive K-ras gene detection. Biosens Bioelectron 2023; 235:115385. [PMID: 37229843 DOI: 10.1016/j.bios.2023.115385] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/29/2023] [Accepted: 05/08/2023] [Indexed: 05/27/2023]
Abstract
Herein, an fluorescence (FL)-electrochemiluminescence (ECL) dual-mode biosensor is constructed based on the dual-signal "turn-on" strategy of functionalized metal-organic frameworks nanosheets (RuMOFNSs)-tetraferrocene for K-ras gene detection, and the mechanism of bursting through front-line orbital theory is explained for the first time. Amino-functionalized tetraferrocene-labeled probe DNA molecules are linked to RuMOFNSs by covalent amide bonds, acting as FL and ECL intensity switches. The target DNA, complementary to the probe DNA, triggers cyclic amplification of the target by nucleic acid exonuclease III (Exo III), repelling tetraferrocene reporter groups away from RuMOFNSs and inhibiting the electron transfer process and photoinduced electron transfer (PET) effect. These phenomena induce a double turn-on of FL and ECL signals with a high signal-to-noise ratio. The developed FL-ECL dual-mode sensing platform provides sensitive detection of the K-ras gene with detection limits of 0.01 fM (the detection range is 1 fM to 1 nM) and 0.003 fM (the detection range is 0.01 fM to 10 pM), respectively. In addition, the proposed dual-mode sensor can be easily extended to detect other disease-related biomarkers by changing the specific target and probe base sequences, depicting potential applications in bioanalysis and early disease diagnosis.
Collapse
Affiliation(s)
- Longshua Qin
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Ting Huang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Hanfeng Cui
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Mengqing Cheng
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Guobing Wei
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Fusheng Liao
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Wei Xiong
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Hedong Jiang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China
| | - Jing Zhang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China.
| | - Hao Fan
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi, 330004, China.
| |
Collapse
|
3
|
Handrea-Dragan IM, Botiz I, Tatar AS, Boca S. Patterning at the micro/nano-scale: Polymeric scaffolds for medical diagnostic and cell-surface interaction applications. Colloids Surf B Biointerfaces 2022; 218:112730. [DOI: 10.1016/j.colsurfb.2022.112730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/15/2022] [Accepted: 07/25/2022] [Indexed: 11/27/2022]
|
4
|
Salek Maghsoudi A, Hassani S, Mirnia K, Abdollahi M. Recent Advances in Nanotechnology-Based Biosensors Development for Detection of Arsenic, Lead, Mercury, and Cadmium. Int J Nanomedicine 2021; 16:803-832. [PMID: 33568907 PMCID: PMC7870343 DOI: 10.2147/ijn.s294417] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 01/14/2021] [Indexed: 12/11/2022] Open
Abstract
Heavy metals cause considerable environmental pollution due to their extent and non-degradability in the environment. Analysis and trace levels of arsenic, lead, mercury, and cadmium as the most toxic heavy metals show that they can cause various hazards in humans' health. To achieve rapid, high-sensitivity methods for analyzing ultra-trace amounts of heavy metals in different environmental and biological samples, novel biosensors have been designed with the participation of strategies applied in nanotechnology. This review attempted to investigate the novel, sensitive, efficient, cost-benefit, point of care, and user-friendly biosensors designed to detect these heavy metals based on functional mechanisms. The study's search strategies included examining the primary databases from 2015 onwards and various keywords focusing on heavy metal biosensors' performance and toxicity mechanisms. The use of aptamers and whole cells as two important bio-functional nanomaterials is remarkable in heavy metal diagnostic biosensors' bioreceptor design. The application of hybridized nanomaterials containing a specific physicochemical function in the presence of a suitable transducer can improve the sensing performance to achieve an integrated detection system. Our study showed that in addition to both labeled and label-free detection strategies, a wide range of nanoparticles and nanocomposites were used to modify the biosensor surface platform in the detection of heavy metals. The detection limit and linear dynamic range as an essential characteristic of superior biosensors for the primary toxic metals are studied. Furthermore, the perspectives and challenges facing the design of heavy metal biosensors are outlined. The development of novel biosensors and the application of nanotechnology, especially in real samples, face challenges such as the capability to simultaneously detect multiple heavy metals, the interference process in complex matrices, the efficiency and stability of nanomaterials implemented in various laboratory conditions.
Collapse
Affiliation(s)
- Armin Salek Maghsoudi
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences, Tehran, Iran
- Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Shokoufeh Hassani
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences, Tehran, Iran
- Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| | - Kayvan Mirnia
- Department of Neonatology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mohammad Abdollahi
- Toxicology and Diseases Group (TDG), Pharmaceutical Sciences Research Center (PSRC), The Institute of Pharmaceutical Sciences (TIPS), Tehran University of Medical Sciences, Tehran, Iran
- Department of Toxicology and Pharmacology, School of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
5
|
Li L, Chen B, Luo L, Liu X, Bi X, You T. Sensitive and selective detection of Hg2+ in tap and canal water via self-enhanced ECL aptasensor based on NH2–Ru@SiO2-NGQDs. Talanta 2021; 222:121579. [DOI: 10.1016/j.talanta.2020.121579] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 08/14/2020] [Accepted: 08/21/2020] [Indexed: 12/24/2022]
|
6
|
Stortini AM, Baldo MA, Moro G, Polo F, Moretto LM. Bio- and Biomimetic Receptors for Electrochemical Sensing of Heavy Metal Ions. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6800. [PMID: 33260737 PMCID: PMC7731017 DOI: 10.3390/s20236800] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 11/25/2020] [Accepted: 11/26/2020] [Indexed: 02/07/2023]
Abstract
Heavy metals ions (HMI), if not properly handled, used and disposed, are a hazard for the ecosystem and pose serious risks for human health. They are counted among the most common environmental pollutants, mainly originating from anthropogenic sources, such as agricultural, industrial and/or domestic effluents, atmospheric emissions, etc. To face this issue, it is necessary not only to determine the origin, distribution and the concentration of HMI but also to rapidly (possibly in real-time) monitor their concentration levels in situ. Therefore, portable, low-cost and high performing analytical tools are urgently needed. Even though in the last decades many analytical tools and methodologies have been designed to this aim, there are still several open challenges. Compared with the traditional analytical techniques, such as atomic absorption/emission spectroscopy, inductively coupled plasma mass spectrometry and/or high-performance liquid chromatography coupled with electrochemical or UV-VIS detectors, bio- and biomimetic electrochemical sensors provide high sensitivity, selectivity and rapid responses within portable and user-friendly devices. In this review, the advances in HMI sensing in the last five years (2016-2020) are addressed. Key examples of bio and biomimetic electrochemical, impedimetric and electrochemiluminescence-based sensors for Hg2+, Cu2+, Pb2+, Cd2+, Cr6+, Zn2+ and Tl+ are described and discussed.
Collapse
Affiliation(s)
| | | | | | | | - Ligia Maria Moretto
- Department of Molecular Science and Nanosystems, Ca’ Foscari University of Venice, Via Torino 155, 30172 Venice, Italy; (A.M.S.); (M.A.B.); (G.M.); (F.P.)
| |
Collapse
|
7
|
Synthesis and sensing behavior of a new multichannel sensor based on thiazolyl ferrocene-rhodamine for Hg2+ detection. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105257] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
8
|
Yun W, Hu Y, Liu Q, Li Y, Wang X, Tang Y, Yang L. Thymine-Hg 2+-thymine coordination chemistry induced entropy driven catalytic reaction to form Hemin/G-quadruplex-HRP-mimicking DNAzyme for colorimetric and visual determination of Hg 2. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2019; 222:117228. [PMID: 31212194 DOI: 10.1016/j.saa.2019.117228] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 05/29/2019] [Accepted: 05/31/2019] [Indexed: 06/09/2023]
Abstract
A sensitive and visible colorimetric strategy was proposed for Hg2+ detection by thymine-Hg2+-thymine (T-Hg2+-T) coordination chemistry and entropy driven catalytic reaction. The entropy driven catalytic reaction is induced by T-Hg2+-T coordination chemistry, resulting the releasing of G-riched sequence. Hemin/G-quadruplex-HRP-mimicking DNAzyme can be formed with the help of hemin, catalyzing TMB to TMB+ with a color change from colorless to blue. The sensitivity of this strategy can be reached to 2 pM, which is significantly improved by entropy driven catalytic reaction. In addition, entropy driven catalytic reaction provides a more reliable and accurate results. This method shows great promise for on-site analysis and in-house diagnosis of Hg2+ in water.
Collapse
Affiliation(s)
- Wen Yun
- State Key Laboratory of Environment-Friendly Energy Material, Southwest University of Science and Technology, Mianyang 621010, PR China; Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 400067, China.
| | - Yuan Hu
- Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 400067, China
| | - Qiulin Liu
- Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 400067, China
| | - Yan Li
- Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 400067, China
| | - Xingmin Wang
- Chongqing Key Laboratory of Catalysis and New Environmental Materials, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 400067, China
| | - Yongjian Tang
- State Key Laboratory of Environment-Friendly Energy Material, Southwest University of Science and Technology, Mianyang 621010, PR China.
| | - Lizhu Yang
- School of Pharmaceutical Sciences, Wenzhou Medical University, Wenzhou, Zhejiang 325035, China.
| |
Collapse
|
9
|
Application of hairpin DNA-based biosensors with various signal amplification strategies in clinical diagnosis. Biosens Bioelectron 2019; 129:164-174. [PMID: 30708263 DOI: 10.1016/j.bios.2019.01.008] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 12/09/2018] [Accepted: 01/03/2019] [Indexed: 01/12/2023]
Abstract
Biosensors have been commonly used in biomedical diagnostic tools in recent years, because of a wide range of application, such as point-of-care monitoring of treatment and disease progression, drug discovery, commonly use food control, environmental monitoring and biomedical research. Additionally, development of DNA biosensors has been increased enormously over the past few years as confirmed by the large number of scientific publications in this field. A wide range of techniques can be used for the development of DNA biosensors, such as DNA nano-machines and various signal amplification strategies. This article selectively reviews the recent advances in DNA base biosensors with various signal amplification strategies for detection of cancer DNA and microRNA, infectious microorganisms, and toxic metal ions.
Collapse
|
10
|
Liu T, Chu Z, Jin W. Electrochemical mercury biosensors based on advanced nanomaterials. J Mater Chem B 2019. [DOI: 10.1039/c9tb00418a] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
This review presents an overview of the synthesis strategies and electrochemical performance of recently developed nanomaterials for the Hg2+ assay.
Collapse
Affiliation(s)
- Tao Liu
- State Key Laboratory of Material-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| | - Zhenyu Chu
- State Key Laboratory of Material-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| | - Wanqin Jin
- State Key Laboratory of Material-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| |
Collapse
|
11
|
Al-Eryani DA, Ahmad W, Mohammad GI, Ali Zainy FM, Alwael H, Bahaffi SO, El-Shahawi MS. An Ultrasensitive Detection Platform for Mercury Ions Speciation in Water Using Procaine Hydrochloride Ion Pair Coupled Extractive Spectrofluorimetry. J Fluoresc 2018; 29:211-219. [DOI: 10.1007/s10895-018-2330-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 11/26/2018] [Indexed: 02/01/2023]
|
12
|
Hu L, Liu Z, Hu Y, Zhan H, Zhu J, Ge X. Fabrication of high-intensity electron transfer electrochemiluminescence interface for Hg2+ detection by using reduced graphene oxide-Au nanoparticles nanocomposites and CdS quantum dots. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2018.06.029] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
13
|
Kun Q, Lin Y, Peng H, Cheng L, Cui H, Hong N, Xiong J, Fan H. A “signal-on” switch electrochemiluminescence biosensor for the detection of tumor cells. J Electroanal Chem (Lausanne) 2018. [DOI: 10.1016/j.jelechem.2017.11.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|