1
|
Mukunda DC, Rodrigues J, Joshi VK, Raghushaker CR, Mahato KK. A comprehensive review on LED-induced fluorescence in diagnostic pathology. Biosens Bioelectron 2022; 209:114230. [PMID: 35421670 DOI: 10.1016/j.bios.2022.114230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 03/19/2022] [Accepted: 03/25/2022] [Indexed: 11/02/2022]
Abstract
Sensitivity, specificity, mobility, and affordability are important criteria to consider for developing diagnostic instruments in common use. Fluorescence spectroscopy has been demonstrating substantial potential in the clinical diagnosis of diseases and evaluating the underlying causes of pathogenesis. A higher degree of device integration with appropriate sensitivity and reasonable cost would further boost the value of the fluorescence techniques in clinical diagnosis and aid in the reduction of healthcare expenses, which is a key economic concern in emerging markets. Light-emitting diodes (LEDs), which are inexpensive and smaller are attractive alternatives to conventional excitation sources in fluorescence spectroscopy, are gaining a lot of momentum in the development of affordable, compact analytical instruments of clinical relevance. The commercial availability of a broad range of LED wavelengths (255-4600 nm) has opened up new avenues for targeting a wide range of clinically significant molecules (both endogenous and exogenous), thereby diagnosing a range of clinical illnesses. As a result, we have specifically examined the uses of LED-induced fluorescence (LED-IF) in preclinical and clinical evaluations of pathological conditions, considering the present advancements in the field.
Collapse
Affiliation(s)
| | - Jackson Rodrigues
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India
| | - Vijay Kumar Joshi
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India
| | - Chandavalli Ramappa Raghushaker
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India
| | - Krishna Kishore Mahato
- Department of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Manipal, Karnataka-576104, India.
| |
Collapse
|
2
|
Evaluation of the Probiotic Properties and the Capacity to Form Biofilms of Various Lactobacillus Strains. Microorganisms 2020; 8:microorganisms8071053. [PMID: 32679908 PMCID: PMC7409210 DOI: 10.3390/microorganisms8071053] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 07/07/2020] [Accepted: 07/10/2020] [Indexed: 12/12/2022] Open
Abstract
Over the last 20 years, Lactobacillus species inhabiting the gastrointestinal tract (GIT) have received much attention, and their health-promoting properties are now well-described. Probiotic effects cannot be generalized, and their uses cover a wide range of applications. It is thus important to proceed to an accurate selection and evaluation of probiotic candidates. We evaluate the probiotic potential of six strains of Lactobacillus in different in vitro models representing critical factors of either survival, efficacy, or both. We characterized the strains for their ability to (i) modulate intestinal permeability using transepithelial electrical resistance (TEER), (ii) form biofilms and resist stressful conditions, and (iii) produce beneficial host and/or bacteria metabolites. Our data reveal the specificity of Lactobacillus strains to modulate intestinal permeability depending on the cell type. The six isolates were able to form spatially organized biofilms, and we provide evidence that the biofilm form is beneficial in a strongly acidic environment. Finally, we demonstrated the ability of the strains to produce γ-aminobutyric acid (GABA) that is involved in the gut-brain axis and beneficial enzymes that promote the bacterial tolerance to bile salts. Overall, our study highlights the specific properties of Lactobacillus strains and their possible applications as biofilms.
Collapse
|
3
|
Celá A, Glatz Z. Homocyclic
o
‐dicarboxaldehydes: Derivatization reagents for sensitive analysis of amino acids and related compounds by capillary and microchip electrophoresis. Electrophoresis 2020; 41:1851-1869. [DOI: 10.1002/elps.202000041] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/27/2020] [Accepted: 06/07/2020] [Indexed: 01/01/2023]
Affiliation(s)
- Andrea Celá
- Department of Biochemistry, Faculty of Science Masaryk University Brno Czech Republic
| | - Zdeněk Glatz
- Department of Biochemistry, Faculty of Science Masaryk University Brno Czech Republic
| |
Collapse
|
4
|
Mentana A, Nardiello D, Palermo C, Centonze D. Accurate glutamate monitoring in foodstuffs by a sensitive and interference-free glutamate oxidase based disposable amperometric biosensor. Anal Chim Acta 2020; 1115:16-22. [PMID: 32370865 DOI: 10.1016/j.aca.2020.04.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 04/07/2020] [Accepted: 04/08/2020] [Indexed: 02/05/2023]
Abstract
L-Glutamate (L-Glu) is a well-known flavour enhancer that is present in several foodstuffs. Although L-Glu is generally recognized as safe, the use in foodstuffs remains controversial and then its fast and accurate monitoring represents an important issue. In this work a sensitive and interference-free disposable amperometric biosensor for glutamate monitoring in foodstuffs was developed. The biosensor was prepared by immobilizing glutamate oxidase through co-crosslinking with bovine serum albumin and glutaraldehyde onto a screen printed disposable platinum electrode modified with a permselective overoxidized polypyrrole film. The enzyme immobilization was optimized by using different experimental procedures. The optimized glutamate biosensor was integrated in a flow injection system and characterized in terms of linearity (0.005-1.0 mM, r2 = 0.992), limits of detection (1.8 μM) and quantitation (5.4 μM), repeatability (RSD < 3%) and stability of response under operational conditions (up to 50 h, over 400 analysis). The biosensor showed also excellent anti-interference characteristics towards the main electroactive interferents present in food matrices, and this allowed the application to the accurate monitoring of glutamate in different foodstuffs.
Collapse
Affiliation(s)
- Annalisa Mentana
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy
| | - Donatella Nardiello
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy
| | - Carmen Palermo
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy
| | - Diego Centonze
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy.
| |
Collapse
|
5
|
Kubáň P, Dvořák M, Kubáň P. Capillary electrophoresis of small ions and molecules in less conventional human body fluid samples: A review. Anal Chim Acta 2019; 1075:1-26. [PMID: 31196414 DOI: 10.1016/j.aca.2019.05.004] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 05/02/2019] [Accepted: 05/03/2019] [Indexed: 01/05/2023]
Abstract
In recent years, advances in sensitive analytical techniques have encouraged the analysis of various compounds in biological fluids. While blood serum, blood plasma and urine still remain the golden standards in clinical, toxicological and forensic science, analyses of other body fluids, such as breast milk, exhaled breath condensate, sweat, saliva, amniotic fluid, cerebrospinal fluid, or capillary blood in form of dried blood spots are becoming more popular. This review article focuses on capillary electrophoresis and microchip electrophoresis of small ions and molecules (e.g. inorganic cations/anions, basic/acidic drugs, small acids/bases, amino acids, peptides and other low molecular weight analytes) in various less conventional human body fluids and hopes to stimulate further interest in the field.
Collapse
Affiliation(s)
- Petr Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
| | - Miloš Dvořák
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic
| | - Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200, Brno, Czech Republic.
| |
Collapse
|
6
|
Denoroy L, Parrot S. Analysis of Amino Acids and Related Compounds by Capillary Electrophoresis. SEPARATION AND PURIFICATION REVIEWS 2016. [DOI: 10.1080/15422119.2016.1212378] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
7
|
Prasad BB, Prasad A, Tiwari MP. Highly selective and sensitive analysis of γ-aminobutyric acid using a new molecularly imprinted polymer modified at the surface of abrasively immobilized multi-walled carbon nanotubes on pencil graphite electrode. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2013.04.043] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
8
|
Hsieh MM, Chang PL. Separation of amino acids by capillary electrophoresis with light-emitting diode-induced fluorescence in the presence of electroosmotic flow. Methods Mol Biol 2013; 984:121-129. [PMID: 23386340 DOI: 10.1007/978-1-62703-296-4_9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
In this chapter, we describe a method to identify amino acids (AA) by capillary electrophoresis in conjunction with light-emitting diode-induced fluorescence (LEDIF). First, amino acids labeled with naphthalene-2,3-dicarboxaldehyde (NDA) in the presence of cyanide are converted to highly fluorescent cyanobenz[f]isoindole (CBI) derivatives. Next, they are separated by gel electrophoresis in the presence of EOF. In the process, the CBI products were excited by a violet LED to produce green fluorescence. In addition to the optical setup of light-emitting diode-induced fluorescence, the preparation of poly(ethylene) oxide for amino acid separation is also described in this chapter.
Collapse
Affiliation(s)
- Ming-Mu Hsieh
- Department of Chemistry, National Kaohsiung Normal University, Kaohsiung, Taiwan
| | | |
Collapse
|
9
|
Gallagher ES, Comi TJ, Braun KL, Aspinwall CA. Online photolytic optical gating of caged fluorophores in capillary zone electrophoresis utilizing an ultraviolet light-emitting diode. Electrophoresis 2012; 33:2903-10. [PMID: 22911376 DOI: 10.1002/elps.201200279] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2012] [Revised: 06/23/2012] [Accepted: 06/25/2012] [Indexed: 11/11/2022]
Abstract
Photolytic optical gating (POG) facilitates rapid, on-line and highly sensitive analyses, though POG utilizes UV lasers for sample injection. We present a low-cost, more portable alternative, employing an ultraviolet light-emitting diode (UV-LED) array to inject caged fluorescent dyes via photolysis. Utilizing the UV-LED array, labeled amino acids were injected with nanomolar limits of detection (270 ± 30 nM and 250 ± 30 nM for arginine and citrulline, respectively). When normalized for the difference in light intensity, the UV-LED array provides comparable sensitivity to POG utilizing UV lasers. Additionally, the UV-LED array yielded sufficient beam quality and stability to facilitate coupling with a Hadamard transform, resulting in increased sensitivity. This work shows, for the first time, the use of an UV-LED for online POG with comparable sensitivity to conventional laser sources but at a lower cost.
Collapse
Affiliation(s)
- Elyssia S Gallagher
- Department of Chemistry and Biochemistry, University of Arizona, Tucson, AZ, USA
| | | | | | | |
Collapse
|
10
|
Shen CC, Tseng WL, Hsieh MM. Selective extraction of thiol-containing peptides in seawater using Tween 20-capped gold nanoparticles followed by capillary electrophoresis with laser-induced fluorescence. J Chromatogr A 2012; 1220:162-8. [DOI: 10.1016/j.chroma.2011.11.057] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2011] [Revised: 11/21/2011] [Accepted: 11/28/2011] [Indexed: 10/25/2022]
|
11
|
Samakashvili S, Ibáñez C, Simó C, Gil-Bea FJ, Winblad B, Cedazo-Mínguez A, Cifuentes A. Analysis of chiral amino acids in cerebrospinal fluid samples linked to different stages of Alzheimer disease. Electrophoresis 2011; 32:2757-64. [PMID: 21983823 DOI: 10.1002/elps.201100139] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2011] [Revised: 04/13/2011] [Accepted: 04/15/2011] [Indexed: 01/22/2023]
Abstract
Chiral micellar electrokinetic chromatography with laser-induced fluorescence detection (chiral-MEKC-LIF) was used to investigate D- and L-amino acid contents in cerebrospinal fluid (CSF) samples related to different Alzheimer disease (AD) stages. CSF samples were taken from (i) control subjects (S1 pool), (ii) subjects showing a mild cognitive impairment who remained stable (S2 pool), (iii) subjects showing an mild cognitive impairment that progressed to AD (S3 pool) and (iv) subjects diagnosed with AD (S4 pool). The optimized procedure only needed 10 μL of CSF and it included sample cleaning, derivatization with FITC and chiral-MEKC-LIF separation. Eighteen standard amino acids were baseline separated with efficiencies up to 703,000 plates/m, high sensitivity (LODs in the nM range) and good resolution (values ranging from 2.6 to 9.5). Using this method, L-Arg, L-Leu, L-Gln, γ-aminobutyric acid, L-Ser, D-Ser, L-Ala, Gly, L-Lys, L-Glu and L-Asp were detected in all the CSF samples. S3 and S4 samples (i.e. AD subjects) showed significant lower amounts of L-Arg L-Lys, L-Glu and L-Asp compared to the non-AD S1 and S2 samples, showing in the S4 group the lowest amounts of L-Arg L-Lys, L-Glu and L-Asp. Moreover, γ-aminobutyric acid was significantly higher in AD subjects with the highest amount also found for S4. No significant differences were observed for the rest of amino acids including D-Ser. Based on the obtained chiral-MEKC-LIF data, it was possible to correctly classify all the samples into the four groups. These results demonstrate that the use of enantioselective procedures as the one developed in this work can provide some new light on the investigations of AD, including the discovery of new biomarkers related to different stages of AD.
Collapse
Affiliation(s)
- Shorena Samakashvili
- Department of Physical and Analytical Chemistry, School of Exact and Natural Sciences, Tbilisi State University, Tbilisi, Georgia
| | | | | | | | | | | | | |
Collapse
|
12
|
Chang PL, Chiu TC, Wang TE, Hu KC, Tsai YH, Hu CC, Bair MJ, Chang HT. Quantitation of branched-chain amino acids in ascites by capillary electrophoresis with light-emitting diode-induced fluorescence detection. Electrophoresis 2011; 32:1080-3. [DOI: 10.1002/elps.201000445] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2010] [Revised: 11/20/2010] [Accepted: 11/22/2010] [Indexed: 02/06/2023]
|
13
|
Szökő É, Tábi T. Analysis of biological samples by capillary electrophoresis with laser induced fluorescence detection. J Pharm Biomed Anal 2010; 53:1180-92. [DOI: 10.1016/j.jpba.2010.07.045] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2010] [Revised: 07/23/2010] [Accepted: 07/27/2010] [Indexed: 12/26/2022]
|
14
|
Liu YM, Liu ZL. Chemiluminescence determination of 20 amino acids and the mechanism study. CHINESE CHEM LETT 2010. [DOI: 10.1016/j.cclet.2010.01.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
15
|
Doong RA, Shih HM. Array-based titanium dioxide biosensors for ratiometric determination of glucose, glutamate and urea. Biosens Bioelectron 2010; 25:1439-46. [DOI: 10.1016/j.bios.2009.10.044] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Revised: 10/07/2009] [Accepted: 10/28/2009] [Indexed: 12/01/2022]
|
16
|
Kao YY, Liu KT, Huang MF, Chiu TC, Chang HT. Analysis of amino acids and biogenic amines in breast cancer cells by capillary electrophoresis using polymer solutions containing sodium dodecyl sulfate. J Chromatogr A 2010; 1217:582-7. [DOI: 10.1016/j.chroma.2009.11.069] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2009] [Revised: 11/20/2009] [Accepted: 11/23/2009] [Indexed: 11/26/2022]
|
17
|
Tůma P, Soukupová M, Samcová E, Štulík K. A determination of submicromolar concentrations of glycine in periaqueductal gray matter microdialyzates using capillary zone electrophoresis with contactless conductivity detection. Electrophoresis 2009; 30:3436-41. [DOI: 10.1002/elps.200900187] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
18
|
Jiang X, Xia Z, Wei W, Gou Q. Direct UV detection of underivatized amino acids using capillary electrophoresis with online sweeping enrichment. J Sep Sci 2009; 32:1927-33. [PMID: 19425023 DOI: 10.1002/jssc.200900013] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This is an original report proposed a CE method for direct analysis of the underivatized amino acids using UV detection with relatively higher sensitivity, which was based on coordination interactions between amino acids and Cu (II) ions. In addition, an online sweeping preconcentration technique was easily combined to improve the detection sensitivity. Satisfying separations of the amino acids were obtained under optimized conditions: 50 mmol/L CuSO4-0.05% HAc-H2O (pH 4.5), and the separation voltage of 15 kV. The LODs for the analytes ranged from 0.1 to 0.5 micromol/L. The linearity of detection for all analytes was two orders of magnitude with the correlation coefficients greater than 0.99. The repeatability was displayed with an RSD less than 3% for migration time and peak height (n = 5). Moreover, some amino acids in real samples of human saliva and green tea were analyzed by this direct UV detection CE method with acceptable sensitivity.
Collapse
Affiliation(s)
- Xuemei Jiang
- College of Bioengineering, Chongqing University, Chongqing, China
| | | | | | | |
Collapse
|
19
|
Zheng L, Song JF. Nickel(II)–baicalein complex modified multiwall carbon nanotube paste electrode and its electrocatalytic oxidation toward glycine. Anal Biochem 2009; 391:56-63. [DOI: 10.1016/j.ab.2009.05.002] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2009] [Revised: 04/30/2009] [Accepted: 05/02/2009] [Indexed: 11/29/2022]
|
20
|
|
21
|
Isa IM, Ab Ghani S. A non-plasticized chitosan based solid state electrode for flow injection analysis of glutamate in food samples. Food Chem 2009. [DOI: 10.1016/j.foodchem.2008.06.043] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
22
|
Liu YM, Liu ZL, Shi YM, Tian W. The determination of glutamine with flow-injection chemiluminescence detection and mechanism study. LUMINESCENCE 2009; 25:50-4. [DOI: 10.1002/bio.1143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
23
|
Xiao D, Yan L, Yuan H, Zhao S, Yang X, Choi MMF. CE with LED-based detection: An update. Electrophoresis 2009; 30:189-202. [DOI: 10.1002/elps.200800415] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Deng YH, Wang H, Zhang HS. Determination of amino acid neurotransmitters in human cerebrospinal fluid and saliva by capillary electrophoresis with laser-induced fluorescence detection. J Sep Sci 2008; 31:3088-97. [DOI: 10.1002/jssc.200800339] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
25
|
Md Isa I, Ab Ghani S. Heterogeneous Membrane and Coated Wire Type Electrode with Chitosan as Ionophore in the Potentiometric Determination of Glutamate: Comparative Study. ELECTROANAL 2008. [DOI: 10.1002/elan.200804243] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
26
|
Lee SH, Jeon CW, Wabaidur SM. Flow-Injection Chemiluminescence Determination of Aspartic Acid in Tea Leaves Using Tris (2,2′-bipyridyl) Ruthenium (II)–Ce(IV) System. J Fluoresc 2008; 18:655-60. [DOI: 10.1007/s10895-008-0387-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2007] [Accepted: 05/12/2008] [Indexed: 11/28/2022]
|
27
|
Capillary electrophoresis analysis of biofluids with a focus on less commonly analyzed matrices. J Chromatogr B Analyt Technol Biomed Life Sci 2008; 866:154-66. [DOI: 10.1016/j.jchromb.2008.01.058] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2007] [Revised: 01/23/2008] [Accepted: 01/24/2008] [Indexed: 12/19/2022]
|
28
|
Simpson SL, Quirino JP, Terabe S. On-line sample preconcentration in capillary electrophoresis. J Chromatogr A 2008; 1184:504-41. [DOI: 10.1016/j.chroma.2007.11.001] [Citation(s) in RCA: 269] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2007] [Revised: 10/30/2007] [Accepted: 11/01/2007] [Indexed: 02/06/2023]
|
29
|
|
30
|
Zhang LY, Sun MX. Capillary electrophoresis of phosphorylated amino acids with fluorescence detection. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 859:30-6. [PMID: 17923447 DOI: 10.1016/j.jchromb.2007.09.022] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2007] [Revised: 08/25/2007] [Accepted: 09/02/2007] [Indexed: 10/22/2022]
Abstract
A rapid and sensitive capillary electrophoresis (CE) method coupled with fluorescence detection was developed for identification of protein phosphorylation by determination of phosphoamino acids. Naphthalene-2,3-dicarboxaldehyde (NDA), a fluorescence derivatization reagent, was used to label protein hydrolysate. The optimal derivatization reaction was performed with 3.5mM NDA, 40 mM NaCN and 20mM borate buffer (pH 10.0) for 15 min. The baseline separation of three phosphorylated amino acids could be obtained in less than 180 s with good repeatability by using 30 mM borate (pH 9.2) containing 2.0mM beta-cyclodextrin (beta-CD) as the running buffer. The detection limits for phosphothreonine, phosphotyrosine and phosphoserine were 7.0 x 10(-9)M, 5.6 x 10(-9)M and 7.2 x 10(-9)M, respectively (S/N=3). Also, the interference from other protein amino acids with large molar excess over that of phosphoamino acids was studied. With beta-casein as the analysis protein, this method was successfully validated.
Collapse
Affiliation(s)
- Li-Yao Zhang
- Key Laboratory of MOE for Plant Development Biology, College of Life Sciences, Wuhan University, Wuhan 430072, China
| | | |
Collapse
|
31
|
|
32
|
Chang PL, Lee KH, Hu CC, Chang HT. CE with sequential light-emitting diode-induced fluorescence and electro-chemiluminescence detections for the determination of amino acids and alkaloids. Electrophoresis 2007; 28:1092-9. [PMID: 17330227 DOI: 10.1002/elps.200600546] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper describes the determination of alkaloids and amino acids (AAs) using CE in conjunction with sequential light-emitting diode-induced fluorescence (LEDIF) and electrochemiluminescence (ECL) detections. In the CE-LEDIF-ECL system, the ECL detector was located in the outlet of the capillary, while the LEDIF detector was positioned 12 cm from the outlet. Naphthalene-2,3-dicarboxaldehyde (NDA) was used to form fluorescent AA-NDA derivatives from AAs possessing primary amino groups, while Ru(bpy)(3) (2+) was used to obtain ECL signals for analytes having secondary and tertiary amino groups. In the presence of poly(ethylene oxide), we accomplished the CE-LEDIF-ECL separation of a mixture of 12 AA-NDA derivatives, anabasine, nicotine, and proline within 11 min. This low-cost CE-LEDIF-ECL system allows the analysis of these AA-NDA derivatives and alkaloids at concentrations in the ranges of 49 nM-0.2 microM and 0.66-4.7 microM, respectively. We applied our CE-LEDIF-ECL system to the analysis of a urine sample and also to tobacco extracts. We obtained good qualitative and quantitative results when using this method with these analytes: the RSDs were below 3.0 and 2.8%, respectively. This CE-LEDIF-ECL system provides the advantages of high efficiency, speed, and sensitivity for the analysis of analytes possessing amino groups.
Collapse
Affiliation(s)
- Po-Ling Chang
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | | | |
Collapse
|
33
|
Chiu TC, Chang HT. Stacking and separation of fluorescent derivatives of amino acids by micellar electrokinetic chromatography in the presence of poly(ethylene oxide). J Chromatogr A 2007; 1146:118-24. [PMID: 17300792 DOI: 10.1016/j.chroma.2007.01.113] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2006] [Revised: 01/20/2007] [Accepted: 01/26/2007] [Indexed: 10/23/2022]
Abstract
A new approach for the analysis of large-volume naphthalene-2,3-dicarboxaldehyde (NDA) derivatives of amino acids by micellar electrokinetic chromatography (MEKC) in conjunction with a purple light-emitting diode-induced fluorescence detection is described. In order to optimize resolution, speed, and stacking efficiency, a discontinuous condition is essential for the analysis of NDA-amino acid derivatives. The optimum conditions use 2.0M TB (pH 10.0) buffer containing 40mM sodium dodecyl sulfate (SDS) to fill the capillary, deionized water to dilute samples, and 200mM TB (pH 9.0) containing 10mM SDS to prepare 0.6% poly(ethylene oxide) (PEO). Once high voltage is applied, PEO solution enters the capillary via electroosmotic flow and SDS micelles interact and thus sweep the NDA-amino acid derivatives having smaller electrophoretic mobilities than that of SDS micelles in the sample zone. When the aggregates between SDS micelles and NDA amino acid derivatives enter PEO zone, they are stacked due to decrease in electric field and increases in viscosity. Under the optimum conditions, the concentration and separation of 0.53-microL 13 NDA-amino acid derivatives that are negatively charged has been demonstrated by using a 60-cm capillary, with the efficiencies 0.3-9.0x10(5) theoretical plates and the LODs at signal-to-noise ratio 3 ranging from 0.30 to 2.76nM. When compared to standard injection (30-cm height for 10s), the approach allows the sensitivity enhancements over the range of 50-800 folds for the derivatives. The new approach has been applied to the analysis of a red wine sample, with great linearity of fluorescent intensity against concentrations (R(2)>0.98) and the RSD (three repetitive runs in one day) values of the migration times for the ten identified amino acids less than 2.8%.
Collapse
Affiliation(s)
- Tai-Chia Chiu
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | |
Collapse
|
34
|
Abstract
CE detectors based on light-emitting diodes (LEDs) as light sources are receiving considerable attention due to their exceptionally high stability, high intensity, low cost, and a variety of wavelengths in the UV and visible spectrum. This article is a comprehensive review on CE methods using LED-based detectors with absorbance and fluorescence detection, and several applications on the determination of riboflavin, bacteria, drug, and amino acids in biological samples are described.
Collapse
Affiliation(s)
- Dan Xiao
- College of Chemical Engineering, Sichuan University, Chengdu, P. R. China.
| | | | | | | |
Collapse
|
35
|
Rammouz G, Lacroix M, Garrigues JC, Poinsot V, Couderc F. The use of naphthalene-2,3-dicarboxaldehyde for the analysis of primary amines using high-performance liquid chromatography and capillary electrophoresis. Biomed Chromatogr 2007; 21:1223-39. [DOI: 10.1002/bmc.893] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
36
|
Hapuarachchi S, Janaway GA, Aspinwall CA. Capillary electrophoresis with a UV light-emitting diode source for chemical monitoring of native and derivatized fluorescent compounds. Electrophoresis 2006; 27:4052-9. [PMID: 16983640 DOI: 10.1002/elps.200600232] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We report the utilization of a high power UV light-emitting diode for fluorescence detection (UV-LED-IF) in CE separations. CE-UV-LED-IF allows analysis of a range of environmentally and biologically important compounds, including PAHs and biogenic amines, including neurotransmitters, amino acids, proteins, and peptides, that have been derivatized with UV-excited fluorogenic labels, e.g., o-phthalic dicarboxaldehyde/beta-mercaptoethanol (OPA/beta-ME). The 365 nm UV-LED was used as a stable, low cost source for detection of UV-excited fluorescent compounds. UV-LED-IF was used with both zonal CE separations and MEKC. Native fluorescence detection of PAHs was accomplished with detection limits ranging from 10 nM to 1.3 microM. Detection limits for OPA/beta-ME-labeled glutamic acid and aspartic acid were 11 and 10 nM, respectively, for off-line labeling, and 47 and 47 nM, respectively, for on-line labeling, comparable to UV-laser-based systems. Analysis of OPA/beta-ME-labeled proteins and peptides was performed with 28 and 47 nM detection limits for BSA and myoglobin, respectively.
Collapse
|
37
|
Chang PL, Chiu TC, Chang HT. Stacking, derivatization, and separation by capillary electrophoresis of amino acids from cerebrospinal fluids. Electrophoresis 2006; 27:1922-31. [PMID: 16703625 DOI: 10.1002/elps.200500496] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
This paper describes the in-column derivatization, stacking, and separation of amino acids by CE in conjunction with light-emitting diode-induced fluorescence using naphthalene-2,3-dicarboxaldehyde (NDA). According to the relative electrophoretic mobilities and the migration direction in tetraborate solution (pH 9.3), the injection order is cyanide, then amino acids, then NDA. Once poly(ethylene oxide) (PEO) migrates through the capillary under EOF, the amino acid.NDA derivatives, amino acids, and CN- ions migrating against the EOF enter the PEO zone. As a result of increases in viscosity and possible interactions with PEO molecules, the reagents/analytes slow down such that they become stacked at the boundary. In comparison with the off-column approach to the analysis of amino acids, our proposed method provides a lower degree of interference from polymeric NDA compounds and other side products. As a result, the plot of the peak height as a function of gamma-aminobutyric acid (GABA) concentration is linear over the range from 10(-5) to 10(-8) M, with the LOD being 4 nM. We demonstrate the diagnostic potential of this approach for the determination of amino acids, including GABA and glutamine, in biological samples through the analysis of large volumes of cerebral spinal fluids without the need for sample pretreatment.
Collapse
Affiliation(s)
- Po-Ling Chang
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | |
Collapse
|