1
|
Bacteriophage-based nano-biosensors for the fast impedimetric determination of pathogens in food samples. Sci Rep 2023; 13:3498. [PMID: 36859463 PMCID: PMC9977096 DOI: 10.1038/s41598-023-30520-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 02/24/2023] [Indexed: 03/03/2023] Open
Abstract
The early and rapid detection of pathogenic microorganisms is of critical importance in addressing serious public health issues. Here, a new bacteriophage-based nano-biosensor was constructed and the electrochemical impedimetric method was fully optimized and applied for the quantitative detection of Escherichia coli O157:H7 in food samples. The impact of using a nanocomposite consisting of gold nanoparticles (AuNPs), multi-walled carbon nanotubes (MWCNTs), and tungsten oxide nanostructures (WO3) on the electrochemical performance of disposable screen printed electrodes was identified using the cyclic voltammetry and electrochemical impedance spectroscopy. The use nanomaterials enabled high capturing sensitivity against the targeting bacterial host cells with the limit of detection of 3.0 CFU/ml. Moreover, selectivity of the covalently immobilized active phage was tested against several non-targeting bacterial strains, where a high specificity was achieved. Thus, the targeting foodborne pathogen was successfully detected in food samples with high specificity, and the sensor provided an excellent recovery rate ranging from 90.0 to 108%. Accordingly, the newly developed phage-biosensor is recommended as a disposable label-free impedimetric biosensor for the quick and real-time monitoring of food quality.
Collapse
|
2
|
Hassan RYA. Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22197539. [PMID: 36236638 PMCID: PMC9573286 DOI: 10.3390/s22197539] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/26/2022] [Accepted: 09/30/2022] [Indexed: 05/17/2023]
Abstract
Modern life quality is strongly supported by the advances made in biosensors, which has been attributed to their crucial and viable contribution in point-of-care (POC) technology developments. POC devices are exploited for the fast tracing of disease progression, rapid analysis of water, and food quality assessment. Blood glucose meters, home pregnancy strips, and COVID-19 rapid tests all represent common examples of successful biosensors. Biosensors can provide great specificity due to the incorporation of selective bio-recognition elements and portability at significantly reduced costs. Electrochemical biosensor platforms are one of the most advantageous of these platforms because they offer many merits, such as being cheap, selective, specific, rapid, and portable. Furthermore, they can be incorporated into smartphones and various analytical approaches in order to increase their sensitivity and many other properties. As a very broad and interdisciplinary area of research and development, biosensors include all disciplines and backgrounds from materials science, chemistry, physics, medicine, microbiology/biology, and engineering. Accordingly, in this state-of-the-art article, historical background alongside the long journey of biosensing construction and development, starting from the Clark oxygen electrode until reaching highly advanced wearable stretchable biosensing devices, are discussed. Consequently, selected examples among the miscellaneous applications of nanobiosensors (such as microbial detection, cancer diagnosis, toxicity analysis, food quality-control assurance, point of care, and health prognosis) are described. Eventually, future perspectives for intelligent biosensor commercialization and exploitation in real-life that is going to be supported by machine learning and artificial intelligence (AI) are stated.
Collapse
Affiliation(s)
- Rabeay Y. A. Hassan
- Applied Organic Chemistry Department, National Research Centre Dokki, Cairo 12622, Egypt; ; Tel.: +20-11292-16152
- Nanoscience Program, University of Science and Technology (UST), Zewail City of Science and Technology, Giza 12578, Egypt
| |
Collapse
|
3
|
Li D, Yang E, Luo Z, Xie Q, Duan Y. An enzyme-mediated universal fluorescent biosensor template for pathogen detection based on a three-dimensional DNA walker and catalyzed hairpin assembly. NANOSCALE 2021; 13:2492-2501. [PMID: 33471006 DOI: 10.1039/d0nr07593k] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
An enzyme-mediated universal fluorescent biosensor template for rapid detection of pathogens was developed based on the strategy of a three-dimensional (3D) DNA walker and catalyzed hairpin assembly (CHA) reaction. In the bacterial recognition step, a strand displacement reaction between bacteria and the double-stranded complex caused the release of the walker strand. The walker strand triggered the DNA walker to produce an enzyme fragment, and the DNA walker used gold nanoparticles (AuNPs) as the track to provide an excellent DNA ligand anchoring area. In the CHA step, the enzyme fragment induced the CHA cycle to yield fluorescence signals, which greatly enhanced the conversion ratio of trigger DNA and the sensitivity of the fluorescent biosensor. The effect of the distance and density of the DNA ligand was studied by adjusting the length of poly-adenine (PolyA), and was further explored by its reaction kinetics. By comparing the maximum reaction rate (Vmax), Michaelis constant (Km) and turnover number (Kcat), the optimized PolyA probe was assessed and identified. In this work, the optimized PolyA-DNA probe exhibited an outstanding sensitivity in Salmonella typhimurium (S. ty) detection, which is 11.9 times and 4.6 times higher than those of the SH-DNA and the MCH treated SH-DNA. Meanwhile, a detection limit of 28.1 CFU mL-1 was achieved in Escherichia coli (E. coli) detection. Furthermore, the biosensor achieved good selectivity and high repeatability with recoveries of 91%-115% for real sample detection. Considering these advantages, this template has great potential as a routine tool for pathogen detection and has wide applications in the field of global public health and food safety.
Collapse
Affiliation(s)
- Dan Li
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-Resource and Eco-Environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, P.R. China.
| | - Enlai Yang
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-Resource and Eco-Environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, P.R. China.
| | - Zewei Luo
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, Shaanxi, P.R. China
| | - Qiyue Xie
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-Resource and Eco-Environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, P.R. China.
| | - Yixiang Duan
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-Resource and Eco-Environment, Ministry of Education, College of Life Sciences, Sichuan University, Chengdu 610065, Sichuan, P.R. China.
| |
Collapse
|
4
|
Chai C, Oh SW. Electrochemical impedimetric biosensors for food safety. Food Sci Biotechnol 2020; 29:879-887. [PMID: 32582450 PMCID: PMC7297935 DOI: 10.1007/s10068-020-00776-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 05/12/2020] [Accepted: 05/17/2020] [Indexed: 12/20/2022] Open
Abstract
Electrochemical impedimetric biosensors (EIBs) have a simple structure and can be used to rapidly and sensitively detect and measure hazards in food. EIBs detect and measure target molecules by transducing biochemical reactions on their surface to electrical signal outputs responding to a sinusoidal electrical signal input. Due to their structural simplicity and analytical sensitivity, EIBs are regarded as the most potent method of food hazard monitoring that can be implemented in the food supply chain. This paper discusses the theoretical background, structure, and construction of EIB and its applications in food safety.
Collapse
Affiliation(s)
- Changhoon Chai
- Department of Applied Animal Science, Kangwon National University, Chuncheon, 24341 Republic of Korea
| | - Se-Wook Oh
- Department of Food and Nutrition, Kookmin University, Seoul, 02707 Republic of Korea
| |
Collapse
|
5
|
Cesewski E, Johnson BN. Electrochemical biosensors for pathogen detection. Biosens Bioelectron 2020; 159:112214. [PMID: 32364936 PMCID: PMC7152911 DOI: 10.1016/j.bios.2020.112214] [Citation(s) in RCA: 417] [Impact Index Per Article: 83.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2019] [Revised: 04/09/2020] [Accepted: 04/10/2020] [Indexed: 12/19/2022]
Abstract
Recent advances in electrochemical biosensors for pathogen detection are reviewed. Electrochemical biosensors for pathogen detection are broadly reviewed in terms of transduction elements, biorecognition elements, electrochemical techniques, and biosensor performance. Transduction elements are discussed in terms of electrode material and form factor. Biorecognition elements for pathogen detection, including antibodies, aptamers, and imprinted polymers, are discussed in terms of availability, production, and immobilization approach. Emerging areas of electrochemical biosensor design are reviewed, including electrode modification and transducer integration. Measurement formats for pathogen detection are classified in terms of sample preparation and secondary binding steps. Applications of electrochemical biosensors for the detection of pathogens in food and water safety, medical diagnostics, environmental monitoring, and bio-threat applications are highlighted. Future directions and challenges of electrochemical biosensors for pathogen detection are discussed, including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, reusable biosensors for process monitoring applications, and low-cost, disposable biosensors.
Collapse
Affiliation(s)
- Ellen Cesewski
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Blake N Johnson
- Department of Industrial and Systems Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Materials Science and Engineering, Virginia Tech, Blacksburg, VA, 24061, USA; Department of Chemical Engineering, Virginia Tech, Blacksburg, VA, 24061, USA.
| |
Collapse
|
6
|
Leva-Bueno J, Peyman SA, Millner PA. A review on impedimetric immunosensors for pathogen and biomarker detection. Med Microbiol Immunol 2020; 209:343-362. [PMID: 32246198 PMCID: PMC7248053 DOI: 10.1007/s00430-020-00668-0] [Citation(s) in RCA: 89] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 03/16/2020] [Indexed: 12/14/2022]
Abstract
Since the discovery of antibiotics in the first quarter of the twentieth century, their use has been the principal approach to treat bacterial infection. Modernized medicine such as cancer therapy, organ transplantation or advanced major surgeries require effective antibiotics to manage bacterial infections. However, the irresponsible use of antibiotics along with the lack of development has led to the emergence of antimicrobial resistance which is considered a serious global threat due to the rise of multidrug-resistant bacteria (Wang et al. in Antibiotic resistance: a rundown of a global crisis, pp. 1645-1658, 2018). Currently employed diagnostics techniques are microscopy, colony counting, ELISA, PCR, RT-PCR, surface-enhanced Raman scattering and others. These techniques provide satisfactory selectivity and sensitivity (Joung et al. in Sens Actuators B Chem 161:824-831, 2012). Nevertheless, they demand specialized personnel and expensive and sophisticated machinery which can be labour-intensive and time-consuming, (Malvano et al. in Sensors (Switzerland) 18:1-11, 2018; Mantzila et al. in Anal Chem 80:1169-1175, 2008). To get around these problems, new technologies such as biosensing and lab-on-a-chip devices have emerged in the last two decades. Impedimetric immunosensors function by applying electrochemical impedance spectroscopy to a biosensor platform using antibodies or other affinity proteins such as Affimers (Tiede et al. in Elife 6(c):1-35, 2017) or other binding proteins (Weiss et al. in Electrochim Acta 50:4248-4256, 2005) as bioreceptors, which provide excellent sensitivity and selectivity. Pre-enrichment steps are not required and this allows miniaturization and low-cost. In this review different types of impedimetric immunosensors are reported according to the type of electrode and their base layer materials, either self-assembled monolayers or polymeric layers, composition and functionalization for different types of bacteria, viruses, fungi and disease biomarkers. Additionally, novel protein scaffolds, both antibody derived and non-antibody derived, used to specifically target the analyte are considered.
Collapse
Affiliation(s)
- J. Leva-Bueno
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT England, UK
| | - Sally A. Peyman
- Molecular and Nanoscale Physics Group, Department of Physics and Astronomy, University of Leeds, Leeds, LS2 9JS England, UK
| | - P. A. Millner
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, LS2 9JT England, UK
| |
Collapse
|
7
|
Yang E, Liao W, Lin Q, An H, Li D, Wei F, Duan Y. Quantitative Analysis of Salmonella typhimurium Based on Elemental-Tags Laser-Induced Breakdown Spectroscopy. Anal Chem 2020; 92:8090-8096. [PMID: 32431153 DOI: 10.1021/acs.analchem.9b05608] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Current rapid bacterial detection methods are dedicated to the classification and identification of bacteria. However, there is still a lack of a method for specific quantitative analysis of certain bacteria. In this work, a method based on elemental-tags laser-induced breakdown spectroscopy (ETLIBS) was developed for the rapid and specific quantitative analysis of Salmonella typhimurium (S. ty). Elemental tags were first synthesized by assembling copper nanoparticles (CuNPs) with poly(thymine) (poly-T) template that linked with the aptamer sequence. Under the specific recognition of the aptamer, S. ty can be fully combined with the elemental tags within 30 min to achieve labeling. Afterward, the silicon nanowires (SiNWs) array modified with Au@Ag nanoparticles (SiNWs-Au@Ag) was employed to capture S. ty in 30 min. Attributed to the rapid analysis superiority of ETLIBS mapping, 100 spectra of SiNWs-Au@Ag/S. ty/CuNPs can be obtained in 5 min. It was found that the peak area of the Cu(I) atomic emission line at 324.75 nm fitted by the Voigt profile was linearly related to the bacterial concentration in the range of 102-106 CFU/mL(R2 = 0.978). Furthermore, ETLIBS mapping achieved a low limit of detection (LOD) of 61 CFU/mL and showed good selectivity to S. ty compared with other bacteria. Besides, the method exhibited preeminent detection performance in spiked samples with the recoveries of 87-113%. With the advantages of rapidity, high efficiency, and specificity, the proposed method is expected to be a powerful tool for bacterial detection.
Collapse
Affiliation(s)
- Enlai Yang
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China
| | - Wenlong Liao
- College of Pharmacy and Biological Engineering, Chengdu University, Chengdu 610106, Sichuan, People's Republic of China
| | - Qingyu Lin
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China
| | - Huifang An
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China
| | - Dan Li
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China
| | - Fujing Wei
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China
| | - Yixiang Duan
- Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, Chengdu 610065, Sichuan, People's Republic of China
| |
Collapse
|
8
|
A capacitive immunosensor for tetracycline estimation using antibody modified polytyramine-alkanethiol ultra-thin film on gold. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114055] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
9
|
Paniel N, Noguer T. Detection of Salmonella in Food Matrices, from Conventional Methods to Recent Aptamer-Sensing Technologies. Foods 2019; 8:E371. [PMID: 31480504 PMCID: PMC6770675 DOI: 10.3390/foods8090371] [Citation(s) in RCA: 46] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/20/2019] [Accepted: 08/26/2019] [Indexed: 01/01/2023] Open
Abstract
Rapid detection of the foodborne pathogen Salmonella in food processing is of crucial importance to prevent food outbreaks and to ensure consumer safety. Detection and quantification of Salmonella species in food samples is routinely performed using conventional culture-based techniques, which are labor intensive, involve well-trained personnel, and are unsuitable for on-site and high-throughput analysis. To overcome these drawbacks, many research teams have developed alternative methods like biosensors, and more particularly aptasensors, were a nucleic acid is used as biorecognition element. The increasing interest in these devices is related to their high specificity, convenience, and relative rapid response. This review aims to present the advances made in these last years in the development of biosensors for the detection and the quantification of Salmonella, highlighting applications on meat from the chicken food chain.
Collapse
Affiliation(s)
- Nathalie Paniel
- Laboratoire BAE, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan, France.
- Unité EMaiRIT'S, Centre Technique de la Conservation des Produits Agricoles (CTCPA), Site Agroparc, 449 Avenue Clément Ader, BP21203, 84911 Avignon, France.
| | - Thierry Noguer
- Laboratoire BAE, Université de Perpignan Via Domitia, 52 Avenue Paul Alduy, 66860 Perpignan, France.
- Laboratoire de Biodiversité et Biotechnologies Microbiennes, USR 3579, Sorbonne Universités (UPMC) Paris 6 et CNRS, Observatoire Océanologique, 66650 Banyuls-sur-Mer, France.
| |
Collapse
|
10
|
Melo AMA, Alexandre DL, Furtado RF, Borges MF, Figueiredo EAT, Biswas A, Cheng HN, Alves CR. Electrochemical immunosensors for Salmonella detection in food. Appl Microbiol Biotechnol 2016; 100:5301-12. [DOI: 10.1007/s00253-016-7548-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Revised: 04/10/2016] [Accepted: 04/12/2016] [Indexed: 01/20/2023]
|
11
|
Wang R, Ni Y, Xu Y, Jiang Y, Dong C, Chuan N. Immuno-capture and in situ detection of Salmonella typhimurium on a novel microfluidic chip. Anal Chim Acta 2014; 853:710-717. [PMID: 25467522 DOI: 10.1016/j.aca.2014.10.042] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Revised: 09/27/2014] [Accepted: 10/24/2014] [Indexed: 11/19/2022]
Abstract
The new method presented in this article achieved the goal of capturing Salmonella typhimurium via immunoreaction and rapid in situ detection of the CdSe/ZnS quantum dots (QDs) labeled S. typhimurium by self-assembly light-emitting diode-induced fluorescence detection (LIF) microsystem on a specially designed multichannel microfluidic chip. CdSe/ZnS QDs were used as fluorescent markers improving detection sensitivity. The microfluidic chip developed in this study was composed of 12 sample channels, 3 mixing zones, and 6 immune reaction zones, which also acted as fluorescence detection zones. QDs-IgG-primary antibody complexes were generated by mixing CdSe/ZnS QDs conjugated secondary antibody (QDs-IgG) and S. typhimurium antibody (primary antibody) in mixing zones. Then, the complexes went into immune reaction zones to label previously captured S. typhimurium in the sandwich mode. The capture rate of S. typhimurium in each detection zone was up to 70%. The enriched QDs-labeled S. typhimurium was detected using a self-assembly LIF microsystem. A good linear relationship was obtained in the range from 3.7×10 to 3.7×10(5) cfu mL(-1) using the equation I=0.1739 log (C)-0.1889 with R(2)=0.9907, and the detection limit was down to 37 cfu mL(-1). The proposed method of online immunolabeling with QDs for in situ fluorescence detection on the designed multichannel microfluidic chip had been successfully used to detect S. typhimurium in pork sample, and it has shown potential advantages in practice.
Collapse
Affiliation(s)
- Renjie Wang
- College of Chemistry and Chemical Engineering, Chongqing University, No. 174, St. Shazheng, Shapingba District, Chongqing, China.
| | - Yanan Ni
- College of Chemistry and Chemical Engineering, Chongqing University, No. 174, St. Shazheng, Shapingba District, Chongqing, China.
| | - Yi Xu
- College of Chemistry and Chemical Engineering, Chongqing University, No. 174, St. Shazheng, Shapingba District, Chongqing, China; National Center for International Research of Micro/Nano-System and New Material Technology, No. 174, St. Shazhengjie, Shapingba District, Chongqing, China; Key Laboratory of Fundamental Science of Micro/Nano-Device and System Technology for National Defense, Chongqing, China.
| | - Yan Jiang
- College of Chemistry and Chemical Engineering, Chongqing University, No. 174, St. Shazheng, Shapingba District, Chongqing, China.
| | - Chunyan Dong
- College of Chemistry and Chemical Engineering, Chongqing University, No. 174, St. Shazheng, Shapingba District, Chongqing, China.
| | - Na Chuan
- College of Chemistry and Chemical Engineering, Chongqing University, No. 174, St. Shazheng, Shapingba District, Chongqing, China.
| |
Collapse
|
12
|
Bahadır EB, Sezgintürk MK. A review on impedimetric biosensors. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2014; 44:248-62. [DOI: 10.3109/21691401.2014.942456] [Citation(s) in RCA: 143] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
13
|
Ahmed A, Rushworth JV, Hirst NA, Millner PA. Biosensors for whole-cell bacterial detection. Clin Microbiol Rev 2014; 27:631-46. [PMID: 24982325 PMCID: PMC4135896 DOI: 10.1128/cmr.00120-13] [Citation(s) in RCA: 368] [Impact Index Per Article: 33.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Bacterial pathogens are important targets for detection and identification in medicine, food safety, public health, and security. Bacterial infection is a common cause of morbidity and mortality worldwide. In spite of the availability of antibiotics, these infections are often misdiagnosed or there is an unacceptable delay in diagnosis. Current methods of bacterial detection rely upon laboratory-based techniques such as cell culture, microscopic analysis, and biochemical assays. These procedures are time-consuming and costly and require specialist equipment and trained users. Portable stand-alone biosensors can facilitate rapid detection and diagnosis at the point of care. Biosensors will be particularly useful where a clear diagnosis informs treatment, in critical illness (e.g., meningitis) or to prevent further disease spread (e.g., in case of food-borne pathogens or sexually transmitted diseases). Detection of bacteria is also becoming increasingly important in antibioterrorism measures (e.g., anthrax detection). In this review, we discuss recent progress in the use of biosensors for the detection of whole bacterial cells for sensitive and earlier identification of bacteria without the need for sample processing. There is a particular focus on electrochemical biosensors, especially impedance-based systems, as these present key advantages in terms of ease of miniaturization, lack of reagents, sensitivity, and low cost.
Collapse
Affiliation(s)
- Asif Ahmed
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Jo V Rushworth
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Natalie A Hirst
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| | - Paul A Millner
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
14
|
Yuan J, Tao Z, Yu Y, Ma X, Xia Y, Wang L, Wang Z. A visual detection method for Salmonella Typhimurium based on aptamer recognition and nanogold labeling. Food Control 2014. [DOI: 10.1016/j.foodcont.2013.09.046] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
15
|
Rushworth JV, Ahmed A, Griffiths HH, Pollock NM, Hooper NM, Millner PA. A label-free electrical impedimetric biosensor for the specific detection of Alzheimer's amyloid-beta oligomers. Biosens Bioelectron 2013; 56:83-90. [PMID: 24480125 DOI: 10.1016/j.bios.2013.12.036] [Citation(s) in RCA: 117] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2013] [Revised: 12/02/2013] [Accepted: 12/16/2013] [Indexed: 12/30/2022]
Abstract
Alzheimer's disease (AD) is the most common form of dementia, with over 37 million sufferers worldwide and a global cost of over $600 billion. There is currently no cure for AD and no reliable method of diagnosis other than post-mortem brain examination. The development of a point-of-care test for AD is an urgent requirement in order to provide earlier diagnosis and, thus, useful therapeutic intervention. Here, we present a novel, label-free impedimetric biosensor for the specific detection of amyloid-beta oligomers (AβO), which are the primary neurotoxic species in AD. AβO have been proposed as the best biomarker for AD and levels of AβO in the blood have been found to correlate with cerebrospinal fluid load. The biorecognition element of our biosensor is a fragment of the cellular prion protein (PrP(C), residues 95-110), a highly expressed synaptic protein which mediates the neuronal binding and toxicity of AβO. During the layer-by-layer sensor construction, biotinylated PrP(C) (95-110) was attached via a biotin/NeutrAvidin bridge to polymer-functionalised gold screen-printed electrodes. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry and scanning electron microscopy were used to validate biosensor assembly and functionality. EIS was employed for biosensor interrogation in the presence of Aβ oligomers or monomers. The biosensor was specific for the detection of synthetic AβO and gave a linear response, without significant detection of monomeric Aβ, down to an equivalent AβO concentration of ~0.5 pM. The biosensor was also able to detect natural, cell-derived AβO present in conditioned medium. The eventual commercialisation of this biosensor system could allow for the early diagnosis and disease monitoring of AD.
Collapse
Affiliation(s)
- Jo V Rushworth
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK.
| | - Asif Ahmed
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| | - Heledd H Griffiths
- School of Molecular and Cellular Biology, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| | - Niall M Pollock
- School of Molecular and Cellular Biology, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| | - Nigel M Hooper
- School of Molecular and Cellular Biology, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| | - Paul A Millner
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
| |
Collapse
|
16
|
Ahmed A, Rushworth JV, Wright JD, Millner PA. Novel impedimetric immunosensor for detection of pathogenic bacteria Streptococcus pyogenes in human saliva. Anal Chem 2013; 85:12118-25. [PMID: 24256123 DOI: 10.1021/ac403253j] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Streptococcus pyogenes , also known as group A streptococcus (GAS), is a Gram positive human pathogen responsible for invasive and noninvasive human infections with a high incidence rate. Traditional detection methods involve cell culture and PCR, which are limited by long processing times or the need for high cost equipment. Impedance-based electrochemical immunosensors provide an alternative by which precise and rapid quantitative detection of the organism can help with rapid clinical decisions. To bring a biosensor for point-of-care applications to market, strict optimization of each level of construction and operation is required. In this paper, commercial screen-printed gold electrodes have been used to construct polytyramine (Ptyr)-based immunosensors. Biotin tagged whole antibodies against S. pyogenes were conjugated to Ptyr amine group via biotin-NeutrAvidin coupling. Sensors were optimized at each level of construction, particularly for Ptyr electrodeposition and antibody concentration, to optimize signal and specificity. Scanning electron microscopy, fluorescence microscopy, and on-sensor analysis (HRP conjugated enhanced chemiluminescence-based semiquantitative method) to detect Ptyr surface amine and bound antibody were performed as supporting techniques. Cumulative and single shot incubations had shown detection range of 100 to 10(5) cells per 10 μL and 100 to 10(4) cells per 10 μL of bacteria in PBS, respectively. Sensors were also able to specifically detect S. pyogenes in 50% (v/v) human saliva, with good selectivity and low cross-reactivity.
Collapse
Affiliation(s)
- Asif Ahmed
- School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds , Leeds LS2 9JT, U.K
| | | | | | | |
Collapse
|
17
|
|
18
|
Peng-Ubol T, Phinyocheep P, Daniel P, Panbangred W, Pilard JF, Thouand G, Durand-Thouand MJ. Plasma-treated polyethylene film: A smart material applied for Salmonella Typhimurium detection. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2012. [DOI: 10.1016/j.msec.2012.08.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
19
|
Holford TR, Davis F, Higson SP. Recent trends in antibody based sensors. Biosens Bioelectron 2012; 34:12-24. [DOI: 10.1016/j.bios.2011.10.023] [Citation(s) in RCA: 203] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2011] [Revised: 10/06/2011] [Accepted: 10/13/2011] [Indexed: 12/29/2022]
|
20
|
Muñoz-Berbel X, Escudé-Pujol R, Vigués N, Cortina-Puig M, García-Aljaro C, Mas J, Muñoz FX. Real Time Automatic System for the Impedimetric Monitoring of Bacterial Growth. ANAL LETT 2011. [DOI: 10.1080/00032719.2011.553008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
21
|
Mejri M, Baccar H, Baldrich E, Del Campo F, Helali S, Ktari T, Simonian A, Aouni M, Abdelghani A. Impedance biosensing using phages for bacteria detection: Generation of dual signals as the clue for in-chip assay confirmation. Biosens Bioelectron 2010; 26:1261-7. [DOI: 10.1016/j.bios.2010.06.054] [Citation(s) in RCA: 65] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2010] [Revised: 06/09/2010] [Accepted: 06/25/2010] [Indexed: 12/01/2022]
|
22
|
Wan Y, Zhang D, Wang Y, Qi P, Hou B. Direct immobilisation of antibodies on a bioinspired architecture as a sensing platform. Biosens Bioelectron 2010; 26:2595-600. [PMID: 21163640 DOI: 10.1016/j.bios.2010.11.013] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2010] [Revised: 10/28/2010] [Accepted: 11/09/2010] [Indexed: 02/07/2023]
Abstract
A sensitive and selective immunosensor for the nonlabeled detection of sulfate-reducing bacteria (SRB) is constructed using a self-polymerised polydopamine film as the immobilisation platform. Self-polymerisation of dopamine is used as a powerful approach for applying multifunctional coatings onto the surface of a gold electrode. The polydopamine film is used not only as the immobilisation platform, but also as a cross-linker reagent for the immobilisation of the anti-SRB antibody. The polydopamine film is loaded with a high density of anti-SRB antibodies linked to the substrate to obtain high response signals. The formation and fabrication of the biosensor and the quantification of antibody anchoring are monitored, and SRB detection is performed by either quartz crystal microbalance (QCM) or electrochemical impedance spectroscopy (EIS). After modeling the impedance Nyquist plots of the SRB/anti-SRB/polydopamine/gold electrode for increasing concentrations of SRB, the electron transfer resistance (R(ct)) is used as a measure of immunocomplex binding. The R(ct) is correlated with the concentration of bacterial cells in the range of 1.8×10(2) to 1.8×10(6) CFU mL(-1); the detection limit is 50 CFU mL(-1). This work demonstrates a new immobilisation platform for the development of a sensitive and label-less impedimetric and piezoelectric immunosensor. This immunosensor may be broadly applied in clinical diagnoses and the monitoring of water environmental pollution. The method proposed is distinct in its ease of application, use of a simple protocol, and mild reaction conditions. These allow it to be applied to a wide variety of materials.
Collapse
Affiliation(s)
- Yi Wan
- Key Lab of Corrosion Science, Shandong Province, Institute of Oceanology, Chinese Academy of Sciences, 7 Nanhai Road, Qingdao 266071, China
| | | | | | | | | |
Collapse
|
23
|
Affiliation(s)
- Benjamin J Privett
- Department of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina 27599, USA
| | | | | |
Collapse
|
24
|
|
25
|
Wan Y, Zhang D, Wang Y, Hou B. A 3D-impedimetric immunosensor based on foam Ni for detection of sulfate-reducing bacteria. Electrochem commun 2010. [DOI: 10.1016/j.elecom.2009.12.017] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
26
|
Ozoemena KI, Mathebula NS, Pillay J, Toschi G, Verschoor JA. Electron transfer dynamics across self-assembled N-(2-mercaptoethyl) octadecanamide/mycolic acid layers: impedimetric insights into the structural integrity and interaction with anti-mycolic acid antibodies. Phys Chem Chem Phys 2010; 12:345-57. [DOI: 10.1039/b915930d] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
27
|
Huang J, Yang G, Meng W, Wu L, Zhu A, Jiao X. An electrochemical impedimetric immunosensor for label-free detection of Campylobacter jejuni in diarrhea patients' stool based on O-carboxymethylchitosan surface modified Fe3O4 nanoparticles. Biosens Bioelectron 2009; 25:1204-11. [PMID: 19932018 DOI: 10.1016/j.bios.2009.10.036] [Citation(s) in RCA: 94] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2009] [Revised: 10/22/2009] [Accepted: 10/23/2009] [Indexed: 10/20/2022]
Abstract
A novel electrochemical impedimetric immunosensor based on O-carboxymethylchitosan surface modified Fe(3)O(4) nanoparticles (denoted as OCMCS-Fe(3)O(4) nanoparticles) was developed for rapid detection of Campylobacter jejuni, which is becoming the most common cause of gastroenteritis in developed countries and raising major public health concerns worldwide. In the present study, anti-FlaA monoclonal antibodies 2D12 (denoted as 2D12McAbs) were immobilized on OCMCS-Fe(3)O(4) nanoparticles. The detection was performed by measuring relative change in impedance before and after 2D12McAbs-Campylobacter jejuni reaction with the technique of electrochemical impedance spectroscopy. Under the optimized conditions, the relative change in impedance was proportional to the logarithmic value of Campylobacter jejuni concentrations in the range of 1.0x10(3) to 1.0x10(7) CFU/mL (r=0.991). The advantages of the OCMCS-Fe(3)O(4) nanoparticle-based immunosensor are simplicity of use, fast response, wide linear range, acceptable reproducibility and long stability. Moreover, the immunosensor could be regenerated by being treated with glycine-HCl buffer solution (pH 2.8). We demonstrate the convenient application of the novel immunosensor for the detection of Campylobacter jejuni in diarrhea patients' stool samples.
Collapse
Affiliation(s)
- Jinlin Huang
- College of Bioscience and Biotechnology, Yangzhou University, Yangzhou, PR China
| | | | | | | | | | | |
Collapse
|
28
|
Escamilla-Gómez V, Campuzano S, Pedrero M, Pingarrón JM. Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisation. Biosens Bioelectron 2009; 24:3365-71. [PMID: 19481924 DOI: 10.1016/j.bios.2009.04.047] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2009] [Revised: 04/20/2009] [Accepted: 04/30/2009] [Indexed: 10/20/2022]
Abstract
Label-free electrochemical impedance immunosensors for the detection and quantification of Escherichia coli (E. coli) using self-assembled monolayers (SAMs)-modified gold screen-printed electrodes (AuSPEs) were developed. Two different immunosensor configurations were tested and compared. In the first one, the immunosensing design was based on the covalent immobilization of anti-E. coli at AuSPEs using the homobifunctional cross-linker 3,3'-dithiobis[sulfosuccinimidylpropionate] (DTSSP). The other one was based on the immobilization of the thiolated antibody onto the electrode surface. In both cases, the evaluation of the developed immunosensors performance was accomplished through the monitoring of the electron-transfer resistance detected by electrochemical impedance spectroscopy (EIS) in the presence of [Fe(CN)(6)(3-)]/[Fe(CN)(6)(4-)] as redox probe. The configuration using the thiolated antibodies gave rise to a better analytical performance, exhibiting a linear relationship between the increment in the electron-transfer resistance (DeltaR(et)) and the logarithmic value of the E. coli concentration in the 5-1.0 x 10(8) cfu mL(-1) range. The limit of detection achieved, with no need for preconcentration or pre-enrichment steps was 3.3 cfu mL(-1). The developed immunosensors showed a high selectivity against Staphylococcus aureus (S. aureus) and Salmonella choleraesuis (S. choleraesuis). The usefulness of the thiolated antibodies-based design for the rapid analysis (1h) of 10 cfu mL(-1)E. coli inoculated river and tap water samples was demonstrated.
Collapse
Affiliation(s)
- Vanessa Escamilla-Gómez
- Departamento Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain
| | | | | | | |
Collapse
|