1
|
Peng W, Li S, Gao H, Su M, Zhou Y, Ding Z, Jiang Q, Yu C. Non-invasive alcohol biosensor based on gold nanoparticles and carbon nanotubes network for dynamic monitoring of sweat alcohol. Bioelectrochemistry 2025; 164:108943. [PMID: 39970623 DOI: 10.1016/j.bioelechem.2025.108943] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2024] [Revised: 02/03/2025] [Accepted: 02/11/2025] [Indexed: 02/21/2025]
Abstract
Intemperance can lead to health issues or other potential harms to society. Consequently, accurate detection of alcohol concentration in human fluid is an essential and challenging task. In this paper, we reported an efficient and reliable method for highly sensitive and selective monitoring of alcohol in sweat. This stretchable alcohol biosensor has been fabricated by transferring multi-walled carbon nanotubes (MWCNTs) film on polydimethylsiloxane (PDMS) substrate followed by immobilization of Au nanoparticles (AuNPs) and alcohol oxidase enzyme (AOx). The biosensor possesses satisfactory mechanical stability, including excellent resistance to stretching, bending and twisting. Sandwich structure formed on the electrode surface by MWCNTs and AuNPs provides excellent electrical conductivity and electrochemical performance for biosensors. The biosensor exhibited a wide linear range from 1.5 μM to 30 mM toward alcohol and the detection limit was 0.5 μM. Furthermore, owing to the specificity of the AOx, the biosensor displayed splendid selectivity. The real sample tests show that the constructed biosensor has the ability to monitor sweat alcohol, and the results were consistent with those obtained by gas chromatography. This research offers a versatile method for the development of flexible electrochemical biosensors, which has promising applications in noninvasive and accurate detection of alcohol in human sweat.
Collapse
Affiliation(s)
- Wenjing Peng
- School of Public Health, Nantong University, Nantong 226019, PR China
| | - Shan Li
- Dongtai People's Hospital, Yancheng, Jiangsu, 224200, China
| | - Hui Gao
- School of Public Health, Nantong University, Nantong 226019, PR China
| | - Mengjie Su
- School of Public Health, Nantong University, Nantong 226019, PR China
| | - Yaqiu Zhou
- School of Public Health, Nantong University, Nantong 226019, PR China
| | - Zhengyuan Ding
- School of Public Health, Nantong University, Nantong 226019, PR China
| | - Qiyu Jiang
- School of Public Health, Nantong University, Nantong 226019, PR China
| | - Chunmei Yu
- School of Public Health, Nantong University, Nantong 226019, PR China.
| |
Collapse
|
2
|
Asgharian H, Kammarchedu V, Soltan Khamsi P, Brustoloni C, Ebrahimi A. Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2. ACS APPLIED MATERIALS & INTERFACES 2024; 16:63142-63154. [PMID: 39470169 DOI: 10.1021/acsami.4c11393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/30/2024]
Abstract
Despite the clinical data showing the importance of ascorbic acid (AA or vitamin C) in managing viral respiratory infections, biosensors for their simultaneous detection are lacking. To address this need, we developed a portable and wireless device for simultaneous detection of AA and SARS-CoV-2 virus by integrating commercial transistors with printed laser-induced graphene (LIG) as the extended gate. We studied the effect of laser printing pass number and showed that with two laser printing passes (2-pass LIG), the sensor sensitivity and limit of detection (LOD) for AA improved by a factor of 1.6 and 12.8, respectively. Using complementary characterization methods, we attribute the improved response to a balanced interplay of crystallinity, defect density, surface area, surface roughness, pore density and diameter, and mechanical integrity/stability. These factors enhance analyte transport, reduce noise/variability, and ensure consistent sensor performance, making 2-pass LIG the most effective material in this work. Our sensors exhibit promising performance for detecting AA with a selective response in the presence of common salivary interfering molecules, with sensitivity and LOD of 73.67 mV/dec and 54.04 nM in 1× phosphate buffered saline and 81.05 mV/dec and 78.34 nM in artificial saliva, respectively. We also showed that functionalization of the 2-pass LIG gate with S-protein antibody enables the detection of SARS-CoV-2 protein antigens with an ultralow LOD of 52 zg/mL─an improvement of more than 10-fold compared to 1-pass LIG─and 4 particles/mL for virion mimics with a selective response against influenza virus and multiple human coronavirus strains. With low signal drift/hysteresis and wireless capabilities, the developed device holds great potential for improving at-home monitoring and clinical decision-making.
Collapse
Affiliation(s)
- Heshmat Asgharian
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Vinay Kammarchedu
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Center for Atomically Thin Multifunctional Coatings, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Pouya Soltan Khamsi
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Caroline Brustoloni
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| | - Aida Ebrahimi
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Center for Atomically Thin Multifunctional Coatings, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
- Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States
| |
Collapse
|
3
|
Colozza N, Mazzaracchio V, Arduini F. Paper-Based Electrochemical (Bio)Sensors for the Detection of Target Analytes in Liquid, Aerosol, and Solid Samples. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2024; 17:127-147. [PMID: 38640070 DOI: 10.1146/annurev-anchem-061522-034228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/21/2024]
Abstract
The last decade has been incredibly fruitful in proving the multifunctionality of paper for delivering innovative electrochemical (bio)sensors. The paper material exhibits unprecedented versatility to deal with complex liquid matrices and facilitate analytical detection in aerosol and solid phases. Such remarkable capabilities are feasible by exploiting the intrinsic features of paper, including porosity, capillary forces, and its easy modification, which allow for the fine designing of a paper device. In this review, we shed light on the most relevant paper-based electrochemical (bio)sensors published in the literature so far to identify the smart functional roles that paper can play to bridge the gap between academic research and real-world applications in the biomedical, environmental, agrifood, and security fields. Our analysis aims to highlight how paper's multifarious properties can be artfully harnessed for breaking the boundaries of the most classical applications of electrochemical (bio)sensors.
Collapse
Affiliation(s)
- Noemi Colozza
- 1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy;
- 2Sense4Med S.R.L., Rome, Italy
| | - Vincenzo Mazzaracchio
- 1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy;
| | - Fabiana Arduini
- 1Department of Chemical Science and Technologies, University of Rome Tor Vergata, Rome, Italy;
- 2Sense4Med S.R.L., Rome, Italy
| |
Collapse
|
4
|
Ma X, Deng L, Zou Z, Pan Z, Feng L, Huang Z, Liang Z, Liu X, Li M, Su Z, Zheng H. Novel portable photoelectrochemical sensor based on CdS/Au/TiO 2 nanotube arrays for sensitive, non-invasive, and instantaneous uric acid detection in saliva. Talanta 2024; 271:125646. [PMID: 38218058 DOI: 10.1016/j.talanta.2024.125646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 01/04/2024] [Accepted: 01/06/2024] [Indexed: 01/15/2024]
Abstract
Uric acid (UA) monitoring is the most effective method for diagnosis and treatment of gout, hyperuricemia, hypertension, and other diseases. However, challenges remain regarding detection efficiency and rapid on-site detection. Here, we first synthesized a CdS/Au/TiO2-NTAs Z-scheme heterojunction material using a titanium dioxide nanotube array (TiO2-NTAs) as the substrate and modified with gold nanoparticles (Au) and cadmium sulfide particles (CdS). This material achieves bandgap alignment to generate a large number of electron-hole pairs under illumination. Then, using CdS/Au/TiO2-NTAs as the working electrode and molecularly imprinted polymers (MIP) as the recognition unit, we constructed a portable photoelectrochemical (PEC) sensor for non-invasive instant detection of UA concentration in human saliva, which has unique advantages in the field of high-sensitivity PEC instant detection. The portable MIP-PEC sensor achieves a linear range of 0.01-50 μM and a detection limit as low as 5.07 nM (S/N = 3). At the same time, the portable MIP-PEC sensor exhibits excellent sensitivity, specificity as well as stability, and shows no statistically significant difference compared to traditional high-performance liquid chromatography (HPLC) in practical sample detection. Compared to traditional PEC modes, this work demonstrates a novel and universal method for high-sensitivity instant detection in the field of PEC.
Collapse
Affiliation(s)
- Xiaolong Ma
- Institute of Life Sciences, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Lijun Deng
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Ziwei Zou
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Ziping Pan
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Linlin Feng
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Zheng Huang
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Zhenwu Liang
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Xinli Liu
- Institute of Life Sciences, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China
| | - Mei Li
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China.
| | - Zhiheng Su
- Pharmaceutical College, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China.
| | - Hua Zheng
- Institute of Life Sciences, Guangxi Medical University, No. 22 Shuang Yong Road, Qingxiu District, Nanning, 530021, China.
| |
Collapse
|
5
|
Qin Y, Xiao D, Gao X, Zhang X, Xu Y. Nanocubic cobalt-containing Prussian blue analogue-derived carbon-coated CoFe alloy nanoparticles for noninvasive uric acid sensing. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2496-2504. [PMID: 38578053 DOI: 10.1039/d4ay00121d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
This work describes an electrochemical sensor for the fast noninvasive detection of uric acid (UA) in saliva. The sensing material was based on a cobalt-containing Prussian blue analogue (Na2-xCo[Fe(CN)6]1-y, PCF). By optimizing the ratio of Co and Fe as 1.5 : 1 in PCF (PCF1.5,0), particles with a regular nanocubic morphology were formed. The calcination of PCF1.5,0 produced a carbon-coated CoFe alloy (CCF1.5), which possessed abundant defects and achieved an excellent electrochemical performance. Subsequently, CCF1.5 was modified on a screen-printed carbon electrode (SPCE) to fabricate the electrochemical sensor, CCF1.5/SPCE, which showed a sensitive and selective response toward salivary UA owing to its good conductivity, sufficient surface active sites and efficient catalytic activity. The determination of UA in artificial saliva achieved the wide linear range of 40 nM-30 μM and the low limit of detection (LOD) of 15.3 nM (3σ/s of 3). The performances of the sensor including its reproducibility, stability and selectivity were estimated to be satisfactory. The content of UA in human saliva was determined and the recovery was in the range of 98-107% and the total RSD was 4.14%. The results confirmed the reliability of CCF1.5/SPCE for application in noninvasive detection.
Collapse
Affiliation(s)
- Yunting Qin
- School of Pharmacy, Chengdu University, No. 2025, Chengluo Avenue, Chengdu, P. R. China
| | - Dan Xiao
- Institute of Advanced Study, Chengdu University, No. 2025, Chengluo Avenue, Chengdu, P. R. China.
- College of Chemical Engineering, Sichuan University, No. 29 Wangjiang Road, Chengdu, P. R. China.
| | - Xilan Gao
- College of Food and Bioengineering, Chengdu University, No. 2025, Chengluo Avenue, Chengdu, P. R. China
| | - Xicui Zhang
- Sichuan Institute of Product Quality Supervision & Inspection, No. 16, Xinmao Street, Chengdu, China.
| | - Yanxue Xu
- Institute of Advanced Study, Chengdu University, No. 2025, Chengluo Avenue, Chengdu, P. R. China.
| |
Collapse
|
6
|
Kappalakandy Valapil K, Filipiak MS, Rekiel W, Jarosińska E, Nogala W, Jönsson-Niedziółka M, Witkowska Nery E. Fabrication of ITO microelectrodes and electrode arrays using a low-cost CO 2 laser plotter. LAB ON A CHIP 2023; 23:3802-3810. [PMID: 37551427 DOI: 10.1039/d3lc00266g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
Good electronic (Rs = ∼5 Ω sq-1) and optical properties (transmittance: >83%) make indium tin oxide (ITO) an attractive electrode substrate. Despite the commercial availability of high-quality ITO and some low-cost methods for direct deposition being in use by now, the definition of patterns is still a concern. Putting their popularity and extensive use aside, the manufacturing of ITO electrodes so far lacks a rapid, highly reproducible, flexible, cost-effective, easy patterning process that could surpass difficult, time-consuming techniques such as lithography. Herein, we present a low-cost method based on CO2 laser irradiation for preparing ITO microelectrodes and electrode arrays. Electrodes of different sizes and shapes were examined to identify the performance of the proposed methods. Direct ablation of the ITO layer was optimized for rectangular electrodes of 25, 50, and 100 μm in width, while laser cutting of scotch tape stencils and subsequent wet etching were used to create circular electrodes with a diameter of 1.75 mm. A multielectrode array system consisting 8 of these circular electrodes was fabricated on a (25 × 25) mm2 plate, characterized electrochemically through cyclic voltammetry (CV) and scanning electrochemical microscopy (SECM), and as an example application used for monitoring the anchoring behavior of HeLa and HepG2 cell cultures through cell-based electrochemical impedance spectroscopy. Together, the direct ablation method and preparation of laser cut stencils form a complete toolbox, which allows for low-cost and fast fabrication of ITO electrodes for a wide variety of applications. To demonstrate the general availability of the method, we have also prepared a batch of electrodes using a laser plotter in a local printing shop, achieving high intra-workshop reproducibility.
Collapse
Affiliation(s)
| | - Marcin Szymon Filipiak
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland.
| | - Weronika Rekiel
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland.
| | - Elżbieta Jarosińska
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland.
| | - Wojciech Nogala
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland.
| | - Martin Jönsson-Niedziółka
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland.
| | - Emilia Witkowska Nery
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, ul. Kasprzaka 44/52, 01-224 Warsaw, Poland.
| |
Collapse
|
7
|
Moyseowicz A, Minta D, Gryglewicz G. Conductive Polymer/Graphene‐based Composites for Next Generation Energy Storage and Sensing Applications. ChemElectroChem 2023. [DOI: 10.1002/celc.202201145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Affiliation(s)
- Adam Moyseowicz
- Department of Process Engineering and Technology of Polymer and Carbon Materials Wrocław University of Science and Technology Wybrzeże Stanisława Wyspiańskiego 27 50-370 Wrocław Poland
| | - Daria Minta
- Department of Process Engineering and Technology of Polymer and Carbon Materials Wrocław University of Science and Technology Wybrzeże Stanisława Wyspiańskiego 27 50-370 Wrocław Poland
| | - Grażyna Gryglewicz
- Department of Process Engineering and Technology of Polymer and Carbon Materials Wrocław University of Science and Technology Wybrzeże Stanisława Wyspiańskiego 27 50-370 Wrocław Poland
| |
Collapse
|
8
|
Văduva M, Baibarac M, Cramariuc O. Functionalization of Graphene Derivatives with Conducting Polymers and Their Applications in Uric Acid Detection. Molecules 2022; 28:molecules28010135. [PMID: 36615329 PMCID: PMC9821842 DOI: 10.3390/molecules28010135] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 12/19/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022] Open
Abstract
In this article, we review recent progress concerning the development of sensorial platforms based on graphene derivatives and conducting polymers (CPs), alternatively deposited or co-deposited on the working electrode (usually a glassy carbon electrode; GCE) using a simple potentiostatic method (often cyclic voltammetry; CV), possibly followed by the deposition of metallic nanoparticles (NPs) on the electrode surface (ES). These materials have been successfully used to detect an extended range of biomolecules of clinical interest, such as uric acid (UA), dopamine (DA), ascorbic acid (AA), adenine, guanine, and others. The most common method is electrochemical synthesis. In the composites, which are often combined with metallic NPs, the interaction between the graphene derivatives-including graphene oxide (GO), reduced graphene oxide (RGO), or graphene quantum dots (GQDs)-and the CPs is usually governed by non-covalent functionalization through π-π interactions, hydrogen bonds, and van der Waals (VW) forces. The functionalization of GO, RGO, or GQDs with CPs has been shown to speed up electron transfer during the oxidation process, thus improving the electrochemical response of the resulting sensor. The oxidation mechanism behind the electrochemical response of the sensor seems to involve a partial charge transfer (CT) from the analytes to graphene derivatives, due to the overlapping of π orbitals.
Collapse
Affiliation(s)
- Mirela Văduva
- National Institute of Materials Physics, Atomistilor Street, No. 405 A, Ilfov, 077125 Magurele, Romania
- Correspondence:
| | - Mihaela Baibarac
- National Institute of Materials Physics, Atomistilor Street, No. 405 A, Ilfov, 077125 Magurele, Romania
| | - Oana Cramariuc
- IT Centre for Science and Technology, Av. Radu Beller Street, No. 25, 011702 Bucharest, Romania
| |
Collapse
|
9
|
Wentland L, Cook JM, Minzlaff J, Ramsey SA, Johnston ML, Fu E. Field-use device for the electrochemical quantification of carbamazepine levels in a background of human saliva. J APPL ELECTROCHEM 2022. [DOI: 10.1007/s10800-022-01785-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
10
|
Chen R, Peng X, Song Y, Du Y. A Paper-Based Electrochemical Sensor Based on PtNP/COF TFPB-DHzDS@rGO for Sensitive Detection of Furazolidone. BIOSENSORS 2022; 12:bios12100904. [PMID: 36291041 PMCID: PMC9599777 DOI: 10.3390/bios12100904] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 09/29/2022] [Accepted: 10/18/2022] [Indexed: 05/31/2023]
Abstract
Herein, a paper-based electrochemical sensor based on PtNP/COFTFPB-DHzDS@rGO was developed for the sensitive detection of furazolidone. A cluster-like covalent organic framework (COFTFPB-DHzDS) was successfully grown on the surface of amino-functional reduced graphene oxide (rGO-NH2) to avoid serious self-aggregation, which was further loaded with platinum nanoparticles (PtNPs) with high catalytic activity as nanozyme to obtain PtNP/COFTFPB-DHzDS@rGO nanocomposites. The morphology of PtNP/COFTFPB-DHzDS@rGO nanocomposites was characterized, and the results showed that the smooth rGO surface became extremely rough after the modification of COFTFPB-DHzDS. Meanwhile, ultra-small PtNPs with sizes of around 1 nm were precisely anchored on COFTFPB-DHzDS to maintain their excellent catalytic activity. The conventional electrodes were used to detect furazolidone and showed a detection limit as low as 5 nM and a linear range from 15 nM to 110 μM. In contrast, the detection limit for the paper-based electrode was 0.23 μM, and the linear range was 0.69-110 μM. The results showed that the paper-based electrode can be used to detect furazolidone. This sensor is a potential candidate for the detection of furazolidone residue in human serum and fish samples.
Collapse
Affiliation(s)
| | | | | | - Yan Du
- Correspondence: or ; Tel.: +86-0791-88120861
| |
Collapse
|
11
|
Zhao P, Liu Y, Chen Y, Yang M, Zhao S, Qi N, Wang Y, Huo D, Hou C. Hemin-Functionalized Microfluidic Chip with Dual-Electric Signal Outputs for Accurate Determination of Uric Acid. ACS APPLIED MATERIALS & INTERFACES 2022; 14:41369-41378. [PMID: 36048632 DOI: 10.1021/acsami.2c07660] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Herein, we develop a hemin-functionalized microfluidic chip with dual-electric signal outputs for accurate determination of uric acid (UA). Hemin is designed as the catalyst, which could trigger a built-in reference signal. Carbon nanotube (CNT) and alkalinized titanium carbide (alk-Ti3C2Tx) are used as attachment substrates to strengthen the signal. Benefiting from the synergistic action of hemin, CNT, and alk-Ti3C2Tx, the hybrid functionalized sensor shows prominent electrochemical capacity, desirable catalytic activity, and unique built-in signal ability. Through density functional theory calculations, the structure-reactivity relationship and possible signal output mechanism are deeply investigated. The functionalized sensor is further integrated into a microfluidic chip to prepare a portable electrochemical sensing platform, in which multiple sample processing steps including primary filtration, target enrichment, and reliable analysis can be conducted step-by-step. Based on the abovementioned designs, the developed functionalized microfluidic platform presents desirable performance in UA determination with a detection limit of 0.41 μM. Furthermore, it is capable of accurately detecting UA in urine samples, providing a promising idea for biomolecule monitoring.
Collapse
Affiliation(s)
- Peng Zhao
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yiyi Liu
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yuanyuan Chen
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Mei Yang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Shixian Zhao
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
- Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College, Chongqing 401331, China
| | - Na Qi
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Yongzhong Wang
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Danqun Huo
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
| | - Changjun Hou
- Key Laboratory for Biorheological Science and Technology of Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, Bioengineering College of Chongqing University, Chongqing 400044, PR China
- Chongqing Key Laboratory of Bio-perception & Intelligent Information Processing, School of Microelectronics and Communication Engineering, Chongqing University, Chongqing 400044, PR China
| |
Collapse
|
12
|
Ning Q, Feng S, Cheng Y, Li T, Cui D, Wang K. Point-of-care biochemical assays using electrochemical technologies: approaches, applications, and opportunities. Mikrochim Acta 2022; 189:310. [PMID: 35918617 PMCID: PMC9345663 DOI: 10.1007/s00604-022-05425-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Accepted: 07/21/2022] [Indexed: 12/12/2022]
Abstract
Against the backdrop of hidden symptoms of diseases and limited medical resources of their investigation, in vitro diagnosis has become a popular mode of real-time healthcare monitoring. Electrochemical biosensors have considerable potential for use in wearable products since they can consistently monitor the physiological information of the patient. This review classifies and briefly compares commonly available electrochemical biosensors and the techniques of detection used. Following this, the authors focus on recent studies and applications of various types of sensors based on a variety of methods to detect common compounds and cancer biomarkers in humans. The primary gaps in research are discussed and strategies for improvement are proposed along the dimensions of hardware and software. The work here provides new guidelines for advanced research on and a wider scope of applications of electrochemical biosensors to in vitro diagnosis.
Collapse
Affiliation(s)
- Qihong Ning
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Shaoqing Feng
- Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China
| | - Yuemeng Cheng
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Tangan Li
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Daxiang Cui
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Kan Wang
- School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Key Laboratory of Thin Film and Microfabrication Technology (Ministry of Education), Shanghai Jiao Tong University, Shanghai, 200240, China.
| |
Collapse
|
13
|
Han SH, Ha YJ, Kang EH, Shin K, Lee YJ, Lee GJ. Electrochemical detection of uric acid in undiluted human saliva using uricase paper integrated electrodes. Sci Rep 2022; 12:12033. [PMID: 35835916 PMCID: PMC9283454 DOI: 10.1038/s41598-022-16176-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 07/06/2022] [Indexed: 11/24/2022] Open
Abstract
In this study, we introduce a uricase-immobilized paper (UOx-paper) integrated electrochemical sensor for detection of uric acid (UA) in saliva. The UOx was immobilized on the detection zone in the wax-patterned paper substrate. This UOx-paper was integrated with a Prussian blue-modified, screen-printed carbon electrode after electropolymerization of o-phenylenediamine to construct an electrochemical cell for small-volume (20 μL) of samples. First, we optimized the fabrication conditions of UOx-paper. Next, the amperometric response of the UOx-paper-based electrochemical UA sensor was analyzed using a known concentration of UA standard solution in artificial saliva at an applied potential of − 0.1 V (versus Ag pseudo-reference electrode). The UOx-paper based electrochemical UA sensor showed a sensitivity of 4.9 μA·mM−1 in a linear range of 50 to 1000 μM (R2 = 0.998), high selectivity and good reproducibility, as well as a limit of detection of 18.7 μM (0.31 mg/dL) UA. Finally, we quantified the UA levels in undiluted saliva samples of healthy controls (n = 20) and gout patients (n = 8). The levels were correlated with those measured with conventional salivary UA enzymatic assays as well as serum UA levels. The UOx-paper-based electrochemical UA sensor is a user-friendly and convenient tool to assess salivary UA levels.
Collapse
Affiliation(s)
- Seong Hyun Han
- Department of Medical Engineering, Kyung Hee University, Graduate School, Seoul, 02447, Republic of Korea
| | - You-Jung Ha
- Division of Rheumatology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Eun Ha Kang
- Division of Rheumatology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea
| | - Kichul Shin
- Division of Rheumatology, Seoul Metropolitan Government-Seoul National University Boramae Medical Centre, Seoul, 07061, Republic of Korea
| | - Yun Jong Lee
- Division of Rheumatology, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea. .,Department of Medical Device Development, Seoul National University Graduate School, Seongnam-si, Gyeonggi-do, 13605, Republic of Korea.
| | - Gi-Ja Lee
- Department of Medical Engineering, Kyung Hee University, Graduate School, Seoul, 02447, Republic of Korea. .,Department of Biomedical Engineering, College of Medicine, Kyung Hee University, #1 Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Republic of Korea.
| |
Collapse
|
14
|
Zhang H, Li X, Zhu Q, Wang Z. The recent development of nanomaterials enhanced paper-based electrochemical analytical devices. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116140] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
15
|
Turkkan G, Bas SZ, Atacan K, Ozmen M. An electrochemical sensor based on a Co 3O 4-ERGO nanocomposite modified screen-printed electrode for detection of uric acid in artificial saliva. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 14:67-75. [PMID: 34904141 DOI: 10.1039/d1ay01744f] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
In this study, we report the fabrication of a nanocomposite consisting of Co3O4 nanoparticles (Co3O4 NPs) and electrochemically reduced graphene oxide (ERGO) on a screen-printed electrode (SPE) and its sensing performance in the electrochemical detection of uric acid (UA). The surface modification of the electrode was confirmed by using a variety of characterization techniques (FE-SEM, XRD, AFM, EDX, WCA, FTIR, and Raman spectroscopy). In addition, the surface modification was electrochemically characterized step by step through CV, EIS and DPV techniques, and the results showed that the Co3O4-ERGO nanocomposite exhibited highly sensitive and selective sensing performance towards the oxidation of UA in 0.1 M (pH 7.0) phosphate buffer solution (PBS). The sensor (Co3O4-ERGO/SPE) signals were observed to be linear to the UA concentration in the range of 5 μM to 500 μM (R2 = 0.9985). After revealing its other performance characteristics, such as repeatability, reproducibility, stability, sensitivity, and selectivity, the sensor was successfully applied to the analysis of UA in artificial saliva samples.
Collapse
Affiliation(s)
- Gizem Turkkan
- Department of Chemistry, Selcuk University, 42250, Konya, Turkey.
| | - Salih Zeki Bas
- Department of Chemistry, Selcuk University, 42250, Konya, Turkey.
| | - Keziban Atacan
- Biomedical, Magnetic and Semiconductor Materials Application and Research Center (BIMAS-RC), Sakarya University, 54187, Sakarya, Turkey
| | - Mustafa Ozmen
- Department of Chemistry, Selcuk University, 42250, Konya, Turkey.
| |
Collapse
|
16
|
Kujawska M, Bhardwaj SK, Mishra YK, Kaushik A. Using Graphene-Based Biosensors to Detect Dopamine for Efficient Parkinson's Disease Diagnostics. BIOSENSORS 2021; 11:433. [PMID: 34821649 PMCID: PMC8615362 DOI: 10.3390/bios11110433] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Revised: 10/26/2021] [Accepted: 10/28/2021] [Indexed: 05/08/2023]
Abstract
Parkinson's disease (PD) is a neurodegenerative disease in which the neurotransmitter dopamine (DA) depletes due to the progressive loss of nigrostriatal neurons. Therefore, DA measurement might be a useful diagnostic tool for targeting the early stages of PD, as well as helping to optimize DA replacement therapy. Moreover, DA sensing appears to be a useful analytical tool in complex biological systems in PD studies. To support the feasibility of this concept, this mini-review explores the currently developed graphene-based biosensors dedicated to DA detection. We discuss various graphene modifications designed for high-performance DA sensing electrodes alongside their analytical performances and interference studies, which we listed based on their limit of detection in biological samples. Moreover, graphene-based biosensors for optical DA detection are also presented herein. Regarding clinical relevance, we explored the development trends of graphene-based electrochemical sensing of DA as they relate to point-of-care testing suitable for the site-of-location diagnostics needed for personalized PD management. In this field, the biosensors are developed into smartphone-connected systems for intelligent disease management. However, we highlighted that the focus should be on the clinical utility rather than analytical and technical performance.
Collapse
Affiliation(s)
- Małgorzata Kujawska
- Department of Toxicology, Poznan University of Medical Sciences, Dojazd 30, 60-631 Poznań, Poland
| | - Sheetal K. Bhardwaj
- Van’t Hoff Institute for Molecular Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, The Netherlands;
- Amsterdam Scientific Instruments B.V., Science Park 106, 1098 XG Amsterdam, The Netherlands
| | - Yogendra Kumar Mishra
- Mads Clausen Institute, NanoSYD, University of Southern Denmark, Alison 2, 6400 Sønderborg, Denmark;
| | - Ajeet Kaushik
- NanoBioTech Laboratory, Health System Engineering, Department of Environmental Engineering, Florida Polytechnic University, Lakeland, FL 33805, USA;
| |
Collapse
|
17
|
Hira SA, Yusuf M, Annas D, Nagappan S, Song S, Park S, Park KH. Recent Advances on Conducting Polymer-Supported Nanocomposites for Nonenzymatic Electrochemical Sensing. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c02043] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Shamim Ahmed Hira
- Department of Chemistry, Pusan National University, Busan 46241, South Korea
| | - Mohammad Yusuf
- Department of Chemistry, Pusan National University, Busan 46241, South Korea
| | - Dicky Annas
- Department of Chemistry, Pusan National University, Busan 46241, South Korea
| | - Saravanan Nagappan
- Department of Chemistry, Pusan National University, Busan 46241, South Korea
| | - Sehwan Song
- Department of Physics, Pusan National University, Busan, 46241, South Korea
| | - Sungkyun Park
- Department of Physics, Pusan National University, Busan, 46241, South Korea
| | - Kang Hyun Park
- Department of Chemistry, Pusan National University, Busan 46241, South Korea
| |
Collapse
|
18
|
Bukharinova MA, Stozhko NY, Novakovskaya EA, Khamzina EI, Tarasov AV, Sokolkov SV. Developing Activated Carbon Veil Electrode for Sensing Salivary Uric Acid. BIOSENSORS 2021; 11:287. [PMID: 34436089 PMCID: PMC8394272 DOI: 10.3390/bios11080287] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 08/16/2021] [Accepted: 08/18/2021] [Indexed: 05/04/2023]
Abstract
The paper describes the development of a carbon veil-based electrode (CVE) for determining uric acid (UA) in saliva. The electrode was manufactured by lamination technology, electrochemically activated and used as a highly sensitive voltammetric sensor (CVEact). Potentiostatic polarization of the electrode at 2.0 V in H2SO4 solution resulted in a higher number of oxygen and nitrogen-containing groups on the electrode surface; lower charge transfer resistance; a 1.5 times increase in the effective surface area and a decrease in the UA oxidation potential by over 0.4 V, compared with the non-activated CVE, which was confirmed by energy dispersive X-ray spectroscopy, electrochemical impedance spectroscopy, chronoamperometry and linear sweep voltammetry. The developed sensor is characterized by a low detection limit of 0.05 µM and a wide linear range (0.09-700 µM). The results suggest that the sensor has perspective applications for quick determination of UA in artificial and human saliva. RSD does not exceed 3.9%, and recovery is 96-105%. UA makes a significant contribution to the antioxidant activity (AOA) of saliva (≈60%). In addition to its high analytical characteristics, the important advantages of the proposed CVEact are the simple, scalable, and cost-effective manufacturing technology and the absence of additional complex and time-consuming modification operations.
Collapse
Affiliation(s)
| | - Natalia Yu. Stozhko
- Scientific and Innovation Center of Sensor Technologies, Department of Physics and Chemistry, Ural State University of Economics, 8 Marta St., 62, 620144 Yekaterinburg, Russia; (M.A.B.); (E.A.N.); (E.I.K.); (A.V.T.); (S.V.S.)
| | | | | | | | | |
Collapse
|
19
|
Microfluidic colorimetric detection platform with sliding hybrid PMMA/paper microchip for human urine and blood sample analysis. Talanta 2021; 231:122362. [PMID: 33965028 DOI: 10.1016/j.talanta.2021.122362] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 03/18/2021] [Accepted: 03/21/2021] [Indexed: 02/07/2023]
Abstract
A microfluidic colorimetric detection (MCD) platform consisting of a sliding hybrid PMMA/paper microchip and a smart analysis system is proposed for the convenient, low-cost and rapid analysis of human urine and whole blood samples. The sliding PMMA/paper microchip comprises a PMMA microfluidic chip for sample injection and transportation, a paper strip for sample filtration (urine) or separation (blood), and a sealed paper-chip detection zone for sample reaction and detection. In the proposed device, the paper-chip is coated with bicinchoninic acid (BCA) and biuret reagent and is then assembled into the PMMA microchip and packaged in aluminum housing. In the detection process, the PMMA/paper microchip is slid partially out of the housing, and 2 μL of sample (urine or whole blood) is dripped onto the sample injection zone. The chip is then slid back into the housing and the sample is filtered/separated by the paper strip and transferred under the effects of capillary action to the sealed paper-chip detection zone. The housing is inserted into the color analysis system and heated at 45 °C for 5 min to produce a purple-colored reaction complex. The complex is imaged using a CCD camera and the RGB color intensity of the image is then analyzed using a smartphone to determine the total protein (TP) concentration of the sample. The effectiveness of the proposed method is demonstrated using TP control samples with known concentrations in the range of 0.03-5.0 g/dL. The detection results obtained for 50 human urine samples obtained from random volunteers are shown to be consistent with those obtained from a conventional hospital analysis system (R2 = 0.992). Moreover, the detection results obtained for the albumin (ALB) and creatine (CRE) concentrations of 50 whole blood samples are also shown to be in good agreement with the results obtained from the hospital analysis system (R2 = 0.982 and 0.988, respectively).
Collapse
|
20
|
Tai WC, Chang YC, Chou D, Fu LM. Lab-on-Paper Devices for Diagnosis of Human Diseases Using Urine Samples-A Review. BIOSENSORS 2021; 11:260. [PMID: 34436062 PMCID: PMC8393526 DOI: 10.3390/bios11080260] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 07/26/2021] [Accepted: 07/29/2021] [Indexed: 12/23/2022]
Abstract
In recent years, microfluidic lab-on-paper devices have emerged as a rapid and low-cost alternative to traditional laboratory tests. Additionally, they were widely considered as a promising solution for point-of-care testing (POCT) at home or regions that lack medical infrastructure and resources. This review describes important advances in microfluidic lab-on-paper diagnostics for human health monitoring and disease diagnosis over the past five years. The review commenced by explaining the choice of paper, fabrication methods, and detection techniques to realize microfluidic lab-on-paper devices. Then, the sample pretreatment procedure used to improve the detection performance of lab-on-paper devices was introduced. Furthermore, an in-depth review of lab-on-paper devices for disease measurement based on an analysis of urine samples was presented. The review concludes with the potential challenges that the future development of commercial microfluidic lab-on-paper platforms for human disease detection would face.
Collapse
Affiliation(s)
- Wei-Chun Tai
- Department of Oral and Maxillofacial Surgery, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung 833, Taiwan;
| | - Yu-Chi Chang
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
| | - Dean Chou
- Department of Biomedical Engineering, National Cheng Kung University, Tainan 701, Taiwan;
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan;
- Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung 912, Taiwan
| |
Collapse
|
21
|
Electrochemical synthesis of composite materials based on titanium carbide and titanium dioxide with poly(N-phenyl-o-phenylenediamine) for selective detection of uric acid. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115481] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
22
|
Novel Portable Sensing System with Integrated Multifunctionality for Accurate Detection of Salivary Uric Acid. BIOSENSORS-BASEL 2021; 11:bios11070242. [PMID: 34356713 PMCID: PMC8301860 DOI: 10.3390/bios11070242] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/11/2021] [Accepted: 07/15/2021] [Indexed: 01/05/2023]
Abstract
Uric acid, as the terminal product of purine metabolism in the body, is an important marker of many diseases. Uric acid is abundant in saliva, offering the possibility of its non-invasive detection. However, it is sensitive to interference in saliva by a variety of factors. A reliable method of processing saliva is centrifugation (CF), but the cost and size of equipment limit its use in everyday life. In this study, a novel portable salivary-sensing system (PSSS) with integrated suction filtration (SF) and temperature insulation was proposed to obtain more accurate salivary uric acid levels through a simple procedure. The PSSS includes a saliva container, a high-sensitive uric acid sensor (UAS), an accompanying printed circuit board (PCB), and a mobile application. The responses produced by the UAS presents excellent linearity (4.6 μA/mM with R2 = 0.9964), selectivity, reproducibility, and stability for the detection of low levels of uric acid. The difference in detection values between the UAS and the commercial sensor is only ~4%. The primary feature of the saliva container is the processing of saliva by SF instead of CF. Samples from CF and SF showed no significant differences regarding uric acid levels, and both exhibited approximately 50% deviation from the untreated samples, while the difference in uric acid levels between the samples after SF and after applying both treatments was ~10%. Besides, insulation of the saliva container can partially eliminate sources of error induced by the environment during uric acid level testing. The PSSS provides a novel strategy for the immediate detection of specific markers in saliva. We believe that the PSSS has promising potential for future application in the rapid saliva testing.
Collapse
|
23
|
|
24
|
Reanpang P, Mool-Am-Kha P, Upan J, Jakmunee J. A novel flow injection amperometric sensor based on carbon black and graphene oxide modified screen-printed carbon electrode for highly sensitive determination of uric acid. Talanta 2021; 232:122493. [PMID: 34074450 DOI: 10.1016/j.talanta.2021.122493] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 04/29/2021] [Accepted: 04/29/2021] [Indexed: 01/23/2023]
Abstract
A simple, rapid, and cost-effective flow injection amperometric (FI-Amp) sensor for sensitive determination of uric acid (UA) was developed based on a new combination of carbon black (CB) and graphene oxide (GO) modified screen-printed carbon electrode (SPCE). The CB-GO nanocomposites were simply synthesized and modified on the working electrode surface to increase electrode conductivity and enhance the sensitivity of UA determination via the electrocatalytic activity toward UA oxidation. The morphologies and electrochemical properties of the synthesized nanomaterials were investigated through scanning electron microscopy (SEM), transmission electron microscopy (TEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). The modified electrode was incorporated with FI-Amp to improve UA detection's sensitivity, stability, and automation. Some parameters affecting sensitivity were optimized, including pH of the electrolyte solution, applied potential, amount of CB-GO suspension, flow rate, injection volume, and reaction coil length. Using an applied potential of +0.35 V (vs Ag/AgCl), the anodic current was linearly proportional to UA concentration over the range of 0.05-2000 μM with a detection limit of 0.01 μM (3 S/N). Besides, the developed method provides a sample throughput of 25 injections h-1, excellent sensitivity (0.0191 μA/μM), selectivity, repeatability (RSD 3.1%, n = 7), and stability (RSD 1.08%, n = 50). The proposed system can tolerate potential interferences commonly found in human urine. Furthermore, a good correlation coefficient between the results obtained from the FI-Amp sensor and a hospital laboratory implies that the proposed system is accurate and can be utilized for UA detection in urine samples.
Collapse
Affiliation(s)
- Preeyaporn Reanpang
- Department of Chemistry, Faculty of Science and Technology, Thammasat University, Lampang, 52190, Thailand
| | - Pijika Mool-Am-Kha
- Research Laboratory for Analytical Instrument and Electrochemistry Innovation, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand; Center of Excellence for Innovation in Chemistry and Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Jantima Upan
- Research Laboratory for Analytical Instrument and Electrochemistry Innovation, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand; Center of Excellence for Innovation in Chemistry and Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand
| | - Jaroon Jakmunee
- Research Laboratory for Analytical Instrument and Electrochemistry Innovation, Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand; Center of Excellence for Innovation in Chemistry and Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Faculty of Science, Chiang Mai University, Chiang Mai, 50200, Thailand.
| |
Collapse
|
25
|
Tseng CC, Ko CH, Lu SY, Yang CE, Fu LM, Li CY. Rapid electrochemical-biosensor microchip platform for determination of microalbuminuria in CKD patients. Anal Chim Acta 2021; 1146:70-76. [PMID: 33461721 DOI: 10.1016/j.aca.2020.12.029] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 12/11/2020] [Accepted: 12/15/2020] [Indexed: 02/01/2023]
Abstract
An electrochemical-biosensor (EC-biosensor) microchip consisting of screen-printed electrodes and a double-layer reagent paper detection zone impregnated with amaranth is proposed for the rapid determination of microalbuminuria (MAU) in human urine samples. Under the action of an applied deposition potential, the amaranth is adsorbed on the electrode surface and the subsequent reaction between the modified surface and the MAU content in the urine sample prompts the formation of an inert layer on the electrode surface. The inert layer impedes the transfer of electrons and hence produces a drop in the response peak current, from which the MAU concentration can then be determined. The measurement results obtained for seven artificial urine samples with known MAU concentrations in the range of 0.1-40 mg/dL show that the measured response peak current is related to the MAU concentration with a determination coefficient of R2 = 0.991 in the low concentration range of 0.1-10 mg/dL and R2 = 0.996 in the high concentration range of 10-40 mg/dL. Furthermore, the detection results obtained for 82 actual chronic kidney disease (CKD) patients show an excellent agreement (R2 = 0.988) with the hospital analysis results. Overall, the results confirm that the proposed detection platform provides a convenient and reliable approach for performing sensitive point-of-care testing (POCT) of the MAU content in human urine samples.
Collapse
Affiliation(s)
- Chin-Chung Tseng
- Department of Internal Medicine, College of Medicine, National Cheng Kung University and Hospital, Tainan, 704, Taiwan
| | - Chien-Hsuan Ko
- Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan
| | - Song-Yu Lu
- Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan
| | - Chia-En Yang
- Office of Physical Education, National Pingtung University of Science and Technology, Pingtung, 912, Taiwan
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan; Graduate Institute of Materials Engineering, National Pingtung University of Science and Technology, Pingtung, 912, Taiwan.
| | - Chi-Yu Li
- Department of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan
| |
Collapse
|
26
|
Terán-Alcocer Á, Bravo-Plascencia F, Cevallos-Morillo C, Palma-Cando A. Electrochemical Sensors Based on Conducting Polymers for the Aqueous Detection of Biologically Relevant Molecules. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:252. [PMID: 33478121 PMCID: PMC7835872 DOI: 10.3390/nano11010252] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/13/2021] [Accepted: 01/14/2021] [Indexed: 12/12/2022]
Abstract
Electrochemical sensors appear as low-cost, rapid, easy to use, and in situ devices for determination of diverse analytes in a liquid solution. In that context, conducting polymers are much-explored sensor building materials because of their semiconductivity, structural versatility, multiple synthetic pathways, and stability in environmental conditions. In this state-of-the-art review, synthetic processes, morphological characterization, and nanostructure formation are analyzed for relevant literature about electrochemical sensors based on conducting polymers for the determination of molecules that (i) have a fundamental role in the human body function regulation, and (ii) are considered as water emergent pollutants. Special focus is put on the different types of micro- and nanostructures generated for the polymer itself or the combination with different materials in a composite, and how the rough morphology of the conducting polymers based electrochemical sensors affect their limit of detection. Polypyrroles, polyanilines, and polythiophenes appear as the most recurrent conducting polymers for the construction of electrochemical sensors. These conducting polymers are usually built starting from bifunctional precursor monomers resulting in linear and branched polymer structures; however, opportunities for sensitivity enhancement in electrochemical sensors have been recently reported by using conjugated microporous polymers synthesized from multifunctional monomers.
Collapse
Affiliation(s)
- Álvaro Terán-Alcocer
- Grupo de Investigación Aplicada en Materiales y Procesos (GIAMP), School of Chemical Sciences and Engineering, Yachay Tech University, Hda. San José s/n y Proyecto Yachay, 100119 Urcuquí, Ecuador; (Á.T.-A.); (F.B.-P.)
| | - Francisco Bravo-Plascencia
- Grupo de Investigación Aplicada en Materiales y Procesos (GIAMP), School of Chemical Sciences and Engineering, Yachay Tech University, Hda. San José s/n y Proyecto Yachay, 100119 Urcuquí, Ecuador; (Á.T.-A.); (F.B.-P.)
| | - Carlos Cevallos-Morillo
- Facultad de Ciencias Químicas, Universidad Central del Ecuador, Francisco Viteri s/n y Gato Sobral, 170129 Quito, Ecuador;
| | - Alex Palma-Cando
- Grupo de Investigación Aplicada en Materiales y Procesos (GIAMP), School of Chemical Sciences and Engineering, Yachay Tech University, Hda. San José s/n y Proyecto Yachay, 100119 Urcuquí, Ecuador; (Á.T.-A.); (F.B.-P.)
| |
Collapse
|
27
|
Baker C, Wagner K, Wagner P, Officer DL, Mawad D. Biofunctional conducting polymers: synthetic advances, challenges, and perspectives towards their use in implantable bioelectronic devices. ADVANCES IN PHYSICS: X 2021. [DOI: 10.1080/23746149.2021.1899850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Affiliation(s)
- Carly Baker
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - Klaudia Wagner
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - Pawel Wagner
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - David L. Officer
- ARC Centre of Excellence for Electromaterials Science and Intelligent Polymer Research Institute, AIIM Faculty, Innovation Campus, University of Wollongong, North Wollongong, Australia
| | - Damia Mawad
- School of Materials Science and Engineering, UNSW Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
28
|
Baharfar M, Rahbar M, Tajik M, Liu G. Engineering strategies for enhancing the performance of electrochemical paper-based analytical devices. Biosens Bioelectron 2020; 167:112506. [PMID: 32823207 DOI: 10.1016/j.bios.2020.112506] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 08/07/2020] [Accepted: 08/07/2020] [Indexed: 12/15/2022]
Abstract
Applications of electrochemical detection methods in microfluidic paper-based analytical devices (μPADs) has revolutionized the area of point-of-care (POC) testing towards highly sensitive and selective quantification of various (bio)chemical analytes in a miniaturized, low-coat, rapid, and user-friendly manner. Shortly after the initiation, these relatively new modulations of μPADs, named as electrochemical paper-based analytical devices (ePADs), gained widespread popularity within the POC research community thanks to the inherent advantages of both electrochemical sensing and usage of paper as a suitable substrate for POC testing platforms. Even though general aspects of ePADs such as applications and fabrication techniques, have already been reviewed multiple times in the literature, herein, we intend to provide a critical engineering insight into the area of ePADs by focusing particularly on the practical strategies utilized to enhance their analytical performance (i.e. sensitivity), while maintaining the desired simplicity and efficiency intact. Basically, the discussed strategies are driven by considering the parameters potentially affecting the generated electrochemical signal in the ePADs. Some of these parameters include the type of filter paper, electrode fabrication methods, electrode materials, fluid flow patterns, etc. Besides, the limitations and challenges associated with the development of ePADs are discussed, and further insights and directions for future research in this field are proposed.
Collapse
Affiliation(s)
- Mahroo Baharfar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Mohammad Rahbar
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Mohammad Tajik
- School of Chemistry, The University of New South Wales, Sydney NSW, 2052, Australia
| | - Guozhen Liu
- Graduate School of Biomedical Engineering, The University of New South Wales, Sydney NSW, 2052, Australia.
| |
Collapse
|
29
|
Design of A Low-Cost and Disposable Paper-Based Immunosensor for the Rapid and Sensitive Detection of Aflatoxin B1. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8030087] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We report a paper-based electrochemical immunosensor made with sustainable materials to detect aflatoxin B1 (AFB1), a highly toxic, carcinogenic mycotoxin found in food. The immunosensor was prepared with a waterproof paper substrate and low-cost graphite-based conductive ink through a simple cut-printing method. The working electrode was functionalized with a drop-cast film of multiwalled carbon nanotubes (MWCNT)/chitosan on which a layer of anti-AFB1 monoclonal antibodies was immobilized covalently. The architecture of the immunosensor was confirmed with polarization-modulated infrared reflection absorption spectroscopy (PM-IRRAS) and electrochemical impedance spectroscopy (EIS), including the effective immobilization of the active layer of anti-AFB1. With EIS as the principle of detection, the immunosensor could detect AFB1 in the range from 1 to 30 ng·mL−1, and detection limit of 0.62 ng·mL−1. This sensitivity is sufficient to detect AFB1 in food according to regulatory agencies. The immunosensor exhibited good repeatability, reproducibility, stability, and selectivity in experiments with a possible interferent. Furthermore, detection of AFB1 in maize flour samples yielded recovery of 97–99%, in a demonstration of the possible use of the paper-based immunosensor to detect AFB1 using extraction solutions from food samples.
Collapse
|
30
|
Lanzalaco S, Molina BG. Polymers and Plastics Modified Electrodes for Biosensors: A Review. Molecules 2020; 25:E2446. [PMID: 32456314 PMCID: PMC7287907 DOI: 10.3390/molecules25102446] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 05/21/2020] [Accepted: 05/22/2020] [Indexed: 02/07/2023] Open
Abstract
Polymer materials offer several advantages as supports of biosensing platforms in terms of flexibility, weight, conformability, portability, cost, disposability and scope for integration. The present study reviews the field of electrochemical biosensors fabricated on modified plastics and polymers, focusing the attention, in the first part, on modified conducting polymers to improve sensitivity, selectivity, biocompatibility and mechanical properties, whereas the second part is dedicated to modified "environmentally friendly" polymers to improve the electrical properties. These ecofriendly polymers are divided into three main classes: bioplastics made from natural sources, biodegradable plastics made from traditional petrochemicals and eco/recycled plastics, which are made from recycled plastic materials rather than from raw petrochemicals. Finally, flexible and wearable lab-on-a-chip (LOC) biosensing devices, based on plastic supports, are also discussed. This review is timely due to the significant advances achieved over the last few years in the area of electrochemical biosensors based on modified polymers and aims to direct the readers to emerging trends in this field.
Collapse
Affiliation(s)
- Sonia Lanzalaco
- Departament d’Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ d’Eduard Maristany, 10-14, Building I, E-08019 Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Campus Diagonal Besòs (EEBE), C/ d’Eduard Maristany 10-14, Edifici IS, 08019 Barcelona, Spain
| | - Brenda G. Molina
- Departament d’Enginyeria Química, EEBE, Universitat Politècnica de Catalunya, C/ d’Eduard Maristany, 10-14, Building I, E-08019 Barcelona, Spain
- Barcelona Research Center in Multiscale Science and Engineering, Universitat Politècnica de Catalunya, Campus Diagonal Besòs (EEBE), C/ d’Eduard Maristany 10-14, Edifici IS, 08019 Barcelona, Spain
| |
Collapse
|