1
|
Madden D, Stephens TM, Scott J, O’Neal Swann C, Prather K, Hoffmeister J, Ding L, Dunn IF, Conner AK, Yuan H. Functional connectivity of default mode network in non-hospitalized patients with post-COVID cognitive complaints. Front Neurosci 2025; 19:1576393. [PMID: 40276574 PMCID: PMC12018477 DOI: 10.3389/fnins.2025.1576393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2025] [Accepted: 03/26/2025] [Indexed: 04/26/2025] Open
Abstract
Introduction Neurologic impairment is common in patients with acute respiratory syndrome coronavirus-2 (SARS-CoV-2) infection. While patients with severe COVID have a higher prevalence of neurologic symptoms, as many as one in five patients with mild COVID may also be affected, exhibiting impaired memory as well as other cognitive dysfunctions. Methods To characterize the effect of COVID on the brain, the current study recruited a group of adults with post-COVID cognitive complaints but with mild, non-hospitalized cases. They were then evaluated through formal neuropsychological testing and underwent functional MRI of the brain. The participants in our study performed nearly as expected for cognitively intact individuals. Additionally, we characterized the functional connectivity of the default mode network (DMN), which is known for cognitive functions including memory as well as the attention functions involved in normal aging and degenerative diseases. Results Along with the retention of functional connectivity in the DMN, our results found the DMN to be associated with neurocognitive performance through region-of-interest and whole-brain analyses. The connectivity between key nodes of the DMN was positively correlated with cognitive scores (r = 0.51, p = 0.02), with higher performers exhibiting higher DMN connectivity. Discussion Our findings provide neuroimaging evidence of the functional connectivity of brain networks among individuals experiencing cognitive deficits beyond the recovery of mild COVID. These imaging outcomes indicate expected functional trends in the brain, furthering understanding and guidance of the DMN and neurocognitive deficits in patients recovering from COVID.
Collapse
Affiliation(s)
- Derek Madden
- Stephenson School of Biomedical Engineering, Gallogly College of Engineering, The University of Oklahoma, Norman, OK, United States
| | - Tressie M. Stephens
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Jim Scott
- Department of Psychiatry and Behavioral Sciences, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Christen O’Neal Swann
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Kiana Prather
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Jordan Hoffmeister
- Department of Psychiatry and Behavioral Sciences, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Lei Ding
- Stephenson School of Biomedical Engineering, Gallogly College of Engineering, The University of Oklahoma, Norman, OK, United States
- Institute for Biomedical Engineering, Science, and Technology, University of Oklahoma, Norman, OK, United States
| | - Ian F. Dunn
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Andrew K. Conner
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
| | - Han Yuan
- Stephenson School of Biomedical Engineering, Gallogly College of Engineering, The University of Oklahoma, Norman, OK, United States
- Department of Neurosurgery, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, United States
- Institute for Biomedical Engineering, Science, and Technology, University of Oklahoma, Norman, OK, United States
| |
Collapse
|
2
|
Kumar R, Hosseinzadehtaher M, Hein N, Shadmand M, Jagadish SVK, Ghanbarian B. Challenges and advances in measuring sap flow in agriculture and agroforestry: A review with focus on nuclear magnetic resonance. FRONTIERS IN PLANT SCIENCE 2022; 13:1036078. [PMID: 36426161 PMCID: PMC9679431 DOI: 10.3389/fpls.2022.1036078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
Sap flow measurement is one of the most effective methods for quantifying plant water use.A better understanding of sap flow dynamics can aid in more efficient water and crop management, particularly under unpredictable rainfall patterns and water scarcity resulting from climate change. In addition to detecting infected plants, sap flow measurement helps select plant species that could better cope with hotter and drier conditions. There exist multiple methods to measure sap flow including heat balance, dyes and radiolabeled tracers. Heat sensor-based techniques are the most popular and commercially available to study plant hydraulics, even though most of them are invasive and associated with multiple kinds of errors. Heat-based methods are prone to errors due to misalignment of probes and wounding, despite all the advances in this technology. Among existing methods for measuring sap flow, nuclear magnetic resonance (NMR) is an appropriate non-invasive approach. However, there are challenges associated with applications of NMR to measure sap flow in trees or field crops, such as producing homogeneous magnetic field, bulkiness and poor portable nature of the instruments, and operational complexity. Nonetheless, various advances have been recently made that allow the manufacture of portable NMR tools for measuring sap flow in plants. The basic concept of the portal NMR tool is based on an external magnetic field to measure the sap flow and hence advances in magnet types and magnet arrangements (e.g., C-type, U-type, and Halbach magnets) are critical components of NMR-based sap flow measuring tools. Developing a non-invasive, portable and inexpensive NMR tool that can be easily used under field conditions would significantly improve our ability to monitor vegetation responses to environmental change.
Collapse
Affiliation(s)
- Ritesh Kumar
- Department of Agronomy, Kansas State University, Manhattan, KS, United States
| | - Mohsen Hosseinzadehtaher
- Department of Electrical & Computer Engineering, University of Illinois, Chicago, IL, United States
| | - Nathan Hein
- Department of Agronomy, Kansas State University, Manhattan, KS, United States
| | - Mohammad Shadmand
- Department of Electrical & Computer Engineering, University of Illinois, Chicago, IL, United States
| | | | - Behzad Ghanbarian
- Porous Media Research Lab, Department of Geology, Kansas State University, Manhattan, KS, United States
| |
Collapse
|
3
|
Improvement of magnetic resonance imaging using a wireless radiofrequency resonator array. Sci Rep 2021; 11:23034. [PMID: 34845314 PMCID: PMC8630230 DOI: 10.1038/s41598-021-02533-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 11/17/2021] [Indexed: 11/21/2022] Open
Abstract
In recent years, new human magnetic resonance imaging systems operating at static magnetic fields strengths of 7 Tesla or higher have become available, providing better signal sensitivity compared with lower field strengths. However, imaging human-sized objects at such high field strength and associated precession frequencies is limited due to the technical challenges associated with the wavelength effect, which substantially disturb the transmit field uniformity over the human body when conventional coils are used. Here we report a novel passive inductively-coupled radiofrequency resonator array design with a simple structure that works in conjunction with conventional coils and requires only to be tuned to the scanner's operating frequency. We show that inductive-coupling between the resonator array and the coil improves the transmit efficiency and signal sensitivity in the targeted region. The simple structure, flexibility, and cost-efficiency make the proposed array design an attractive approach for altering the transmit field distribution specially at high field systems, where the wavelength is comparable with the tissue size.
Collapse
|
4
|
Uchiyama Y, Sakai H, Ando T, Tachibana A, Sadato N. BOLD signal response in primary visual cortex to flickering checkerboard increases with stimulus temporal frequency in older adults. PLoS One 2021; 16:e0259243. [PMID: 34735509 PMCID: PMC8568270 DOI: 10.1371/journal.pone.0259243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 10/15/2021] [Indexed: 11/18/2022] Open
Abstract
Many older adults have difficulty seeing brief visual stimuli which younger adults can easily recognize. The primary visual cortex (V1) may induce this difficulty. However, in neuroimaging studies, the V1 response change to the increase of temporal frequency of visual stimulus in older adults was unclear. Here we investigated the association between the temporal frequency of flickering stimuli and the BOLD activity within V1 in older adults, using surface-based fMRI analysis. The fMRI data from 29 healthy older participants stimulated by contrast-reversing checkerboard at temporal flicker frequencies of 2, 4, and 8 Hz were obtained. The participants also performed a useful field of view (UFOV) test. The slope coefficient of BOLD activity regarding the temporal frequency of the visual stimulus averaged within V1 regions of interest was positive and significantly different from zero. Group analysis in the V1 showed significant clusters with positive slope and no significant clusters with a negative slope. The correlation coefficient between the slope coefficient and UFOV performance was not significant. The results indicated that V1 BOLD response to a flickering visual stimulus increases as the stimulus temporal frequency increases from 2 to 8 Hz in older adults.
Collapse
Affiliation(s)
- Yuji Uchiyama
- Human Science Research Domain, Strategic Research Division, Toyota Central R&D Labs., Inc., Nagakute, Aichi, Japan
- * E-mail:
| | - Hiroyuki Sakai
- Human Science Research Domain, Strategic Research Division, Toyota Central R&D Labs., Inc., Nagakute, Aichi, Japan
| | - Takafumi Ando
- Human Science Research Domain, Strategic Research Division, Toyota Central R&D Labs., Inc., Nagakute, Aichi, Japan
| | - Atsumichi Tachibana
- Human Science Research Domain, Strategic Research Division, Toyota Central R&D Labs., Inc., Nagakute, Aichi, Japan
| | - Norihiro Sadato
- Division of Cerebral Integration, Department of System Neuroscience, National Institute for Physiological Sciences, Okazaki, Aichi, Japan
| |
Collapse
|
5
|
Bollmann S, Barth M. New acquisition techniques and their prospects for the achievable resolution of fMRI. Prog Neurobiol 2020; 207:101936. [PMID: 33130229 DOI: 10.1016/j.pneurobio.2020.101936] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 09/10/2020] [Accepted: 10/18/2020] [Indexed: 01/17/2023]
Abstract
This work reviews recent advances in technologies for functional magnetic resonance imaging (fMRI) of the human brain and highlights the push for higher functional specificity based on increased spatial resolution and specific MR contrasts to reveal previously undetectable functional properties of small-scale cortical structures. We discuss how the combination of MR hardware, advanced acquisition techniques and various MR contrast mechanisms have enabled recent progress in functional neuroimaging. However, these advanced fMRI practices have only been applied to a handful of neuroscience questions to date, with the majority of the neuroscience community still using conventional imaging techniques. We thus discuss upcoming challenges and possibilities for fMRI technology development in human neuroscience. We hope that readers interested in functional brain imaging acquire an understanding of current and novel developments and potential future applications, even if they don't have a background in MR physics or engineering. We summarize the capabilities of standard fMRI acquisition schemes with pointers to relevant literature and comprehensive reviews and introduce more recent developments.
Collapse
Affiliation(s)
- Saskia Bollmann
- Centre for Advanced Imaging, The University of Queensland, Brisbane, Australia
| | - Markus Barth
- Centre for Advanced Imaging, The University of Queensland, Brisbane, Australia; School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, Australia; ARC Training Centre for Innovation in Biomedical Imaging Technology, The University of Queensland, Brisbane, QLD, Australia.
| |
Collapse
|
6
|
Peng SL, Yang HC, Chen CM, Shih CT. Short- and long-term reproducibility of BOLD signal change induced by breath-holding at 1.5 and 3 T. NMR IN BIOMEDICINE 2020; 33:e4195. [PMID: 31885110 DOI: 10.1002/nbm.4195] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2019] [Revised: 09/09/2019] [Accepted: 09/09/2019] [Indexed: 06/10/2023]
Abstract
Cerebrovascular reactivity (CVR) can give insight into the cerebrovascular function. CVR can be estimated by measuring a blood-oxygen-level-dependent (BOLD) response combined with breath-holding (BH). The reproducibility of this technique has been addressed and existing studies have focused on short-term reproducibility using a 3 T magnetic resonance imaging (MRI) system. However, little is known about the long-term reproducibility of this procedure and the corresponding reproducibility using a 1.5 T MRI system. Here, we systematically examined the short- and long-term reproducibility of BOLD responses to BH across field strengths. Nine subjects participated in three MRI sessions separated by 30 minutes (sessions 1 and 2: short term) and 68-92 days (sessions 1 and 3, long term) at both 1.5 and 3 T MRI. Our findings revealed that significant differences between field strengths were detected in the activated gray matter volume and BOLD signal change (both P < 0.001), with smaller magnitudes at 1.5 T. However, activation patterns were reproducible, independent of the time interval, brain region or field strength. All interscan coefficient of variation values were below the 33% fiducial limit, and the intraclass correlation coefficient values were above 0.4, which is usually considered the acceptability limit in functional studies. These findings suggest that the response of BOLD signal to BH for assessing CVR is reproducible over time at 1.5 and 3 T. This technique can be considered a tool for monitoring longitudinal changes in patients with cerebrovascular diseases, and its use should be encouraged for clinical 1.5 T MRI systems.
Collapse
Affiliation(s)
- Shin-Lei Peng
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan
| | - Hui-Chieh Yang
- Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan
| | - Chun-Ming Chen
- Department of Radiology, China Medical University Hospital, Taichung, Taiwan
| | - Cheng-Ting Shih
- Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, Taichung, Taiwan
| |
Collapse
|
7
|
Chen JE, Polimeni JR, Bollmann S, Glover GH. On the analysis of rapidly sampled fMRI data. Neuroimage 2019; 188:807-820. [PMID: 30735828 PMCID: PMC6984348 DOI: 10.1016/j.neuroimage.2019.02.008] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2018] [Revised: 01/11/2019] [Accepted: 02/04/2019] [Indexed: 02/08/2023] Open
Abstract
Recent advances in parallel imaging and simultaneous multi-slice techniques have permitted whole-brain fMRI acquisitions at sub-second sampling intervals, without significantly sacrificing the spatial coverage and resolution. Apart from probing brain function at finer temporal scales, faster sampling rates may potentially lead to enhanced functional sensitivity, owing possibly to both cleaner neural representations (due to less aliased physiological noise) and additional statistical benefits (due to more degrees of freedom for a fixed scan duration). Accompanying these intriguing aspects of fast acquisitions, however, confusion has also arisen regarding (1) how to preprocess/analyze these fast fMRI data, and (2) what exactly is the extent of benefits with fast acquisitions, i.e., how fast is fast enough for a specific research aim? The first question is motivated by the altered spectral distribution and noise characteristics at short sampling intervals, while the second question seeks to reconcile the complicated trade-offs between the functional contrast-to-noise ratio and the effective degrees of freedom. Although there have been recent efforts to empirically approach different aspects of these two questions, in this work we discuss, from a theoretical perspective accompanied by some illustrative, proof-of-concept experimental in vivo human fMRI data, a few considerations that are rarely mentioned, yet are important for both preprocessing and optimizing statistical inferences for studies that employ acquisitions with sub-second sampling intervals. Several summary recommendations include concerns regarding advisability of relying on low-pass filtering to de-noise physiological contributions, employment of statistical models with sufficient complexity to account for the substantially increased serial correlation, and cautions regarding using rapid sampling to enhance functional sensitivity given that different analysis models may associate with distinct trade-offs between contrast-to-noise ratios and the effective degrees of freedom. As an example, we demonstrate that as TR shortens, the intrinsic differences in how noise is accommodated in general linear models and Pearson correlation analyses (assuming Gaussian distributed stochastic signals and noise) can result in quite different outcomes, either gaining or losing statistical power.
Collapse
Affiliation(s)
- Jingyuan E Chen
- Department of Radiology, Stanford University, Stanford, CA, USA; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA.
| | - Jonathan R Polimeni
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, USA; Department of Radiology, Harvard Medical School, Boston, MA, USA; Harvard-Massachusetts Institute of Technology Division of Health Sciences and Technology, Cambridge, MA, USA
| | - Saskia Bollmann
- Centre for Advanced Imaging, The University of Queensland, Brisbane, QLD 4072, Australia
| | - Gary H Glover
- Department of Radiology, Stanford University, Stanford, CA, USA
| |
Collapse
|
8
|
Optimized partial-coverage functional analysis pipeline (OPFAP): a semi-automated pipeline for skull stripping and co-registration of partial-coverage, ultra-high-field functional images. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2018; 31:621-632. [PMID: 29845434 DOI: 10.1007/s10334-018-0690-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 05/10/2018] [Accepted: 05/13/2018] [Indexed: 10/16/2022]
Abstract
OBJECTIVE Ultra-high-field functional MRI (UHF-fMRI) allows for higher spatiotemporal resolution imaging. However, higher-resolution imaging entails coverage limitations. Processing partial-coverage images using standard pipelines leads to sub-optimal results. We aimed to develop a simple, semi-automated pipeline for processing partial-coverage UHF-fMRI data using widely used image processing algorithms. MATERIALS AND METHODS We developed automated pipelines for optimized skull stripping and co-registration of partial-coverage UHF functional images, using built-in functions of the Centre for Functional Magnetic Resonance Imaging of the Brain's (FMRIB's) Software library (FSL) and advanced normalization tools. We incorporated the pipelines into the FSL's functional analysis pipeline and provide a semi-automated optimized partial-coverage functional analysis pipeline (OPFAP). RESULTS Compared to the standard pipeline, the OPFAP yielded images with 15 and 30% greater volume of non-zero voxels after skull stripping the functional and anatomical images, respectively (all p = 0.0004), which reflected the conservation of cortical voxels lost when the standard pipeline was used. The OPFAP yielded the greatest Dice and Jaccard coefficients (87 and 80%, respectively; all p < 0.0001) between the co-registered participant gyri maps and the template gyri maps, demonstrating the goodness of the co-registration results. Furthermore, the greatest volume of group-level activation in the most number of functionally relevant regions was observed when the OPFAP was used. Importantly, group-level activations were not observed when using the standard pipeline. CONCLUSION These results suggest that the OPFAP should be used for processing partial-coverage UHF-fMRI data for detecting high-resolution macroscopic blood oxygenation level-dependent activations.
Collapse
|
9
|
Vaidya MV, Lazar M, Deniz CM, Haemer GG, Chen G, Bruno M, Sodickson DK, Lattanzi R, Collins CM. Improved detection of fMRI activation in the cerebellum at 7T with dielectric pads extending the imaging region of a commercial head coil. J Magn Reson Imaging 2018; 48:431-440. [PMID: 29357200 DOI: 10.1002/jmri.25936] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 12/09/2017] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND There is growing interest in detecting cerebro-cerebellar circuits, which requires adequate blood oxygenation level dependent contrast and signal-to-noise ratio (SNR) throughout the brain. Although 7T scanners offer increased SNR, coverage of commercial head coils is currently limited to the cerebrum. PURPOSE To improve cerebellar functional MRI (fMRI) at 7T with high permittivity material (HPM) pads extending the sensitivity of a commercial coil. STUDY TYPE Simulations were used to determine HPM pad configuration and assess radiofrequency (RF) safety. In vivo experiments were performed to evaluate RF field distributions and SNR and assess improvements of cerebellar fMRI. SUBJECTS Eight healthy volunteers enrolled in a prospective motor fMRI study with and without HPM. FIELD STRENGTH/SEQUENCE Gradient echo (GRE) echo planar imaging for fMRI, turbo FLASH for flip angle mapping, GRE sequence for SNR maps, and T1 -weighted MPRAGE were acquired with and without HPM pads at 7T. ASSESSMENT Field maps, SNR maps, and anatomical images were evaluated for coverage. Simulation results were used to assess SAR levels of the experiment. Activation data from fMRI experiments were compared with and without HPM pads. STATISTICAL TESTS: fMRI data were analyzed using FEAT FSL for each subject followed by group level analysis using paired t-test of acquisitions with and without HPM. RESULTS Simulations showed 52% improvement in transmit efficiency in cerebellum with HPM and SAR levels well below recommended limits. Experiments showed 27% improvement in SNR in cerebellum and improvement in coverage on T1 -weighted images. fMRI showed greater cerebellar activation in individual subjects with the HPM pad present (Z > = 4), especially in inferior slices of cerebellum, with 59% average increase in number of activated voxels in the cerebellum. Group-level analysis showed improved functional activation (Z > = 2.3) in cerebellar regions with HPM pads without loss of measured activation elsewhere. DATA CONCLUSION HPM pads can improve cerebellar fMRI at 7T with a commonly-used head coil without compromising RF safety. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2018;48:431-440.
Collapse
Affiliation(s)
- Manushka V Vaidya
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Mariana Lazar
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Cem M Deniz
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Gillian G Haemer
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Gang Chen
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Mary Bruno
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Daniel K Sodickson
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Riccardo Lattanzi
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| | - Christopher M Collins
- Center for Advanced Imaging Innovation and Research (CAI2R) and Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA.,The Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
| |
Collapse
|
10
|
Yoo PE, John SE, Farquharson S, Cleary JO, Wong YT, Ng A, Mulcahy CB, Grayden DB, Ordidge RJ, Opie NL, O'Brien TJ, Oxley TJ, Moffat BA. 7T-fMRI: Faster temporal resolution yields optimal BOLD sensitivity for functional network imaging specifically at high spatial resolution. Neuroimage 2017; 164:214-229. [PMID: 28286317 DOI: 10.1016/j.neuroimage.2017.03.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Revised: 03/01/2017] [Accepted: 03/01/2017] [Indexed: 12/30/2022] Open
Abstract
Recent developments in accelerated imaging methods allow faster acquisition of high spatial resolution images. This could improve the applications of functional magnetic resonance imaging at 7 Tesla (7T-fMRI), such as neurosurgical planning and Brain Computer Interfaces (BCIs). However, increasing the spatial and temporal resolution will both lead to signal-to-noise ratio (SNR) losses due to decreased net magnetization per voxel and T1-relaxation effect, respectively. This could potentially offset the SNR efficiency gains made with increasing temporal resolution. We investigated the effects of varying spatial and temporal resolution on fMRI sensitivity measures and their implications on fMRI-based BCI simulations. We compared temporal signal-to-noise ratio (tSNR), observed percent signal change (%∆S), volumes of significant activation, Z-scores and decoding performance of linear classifiers commonly used in BCIs across a range of spatial and temporal resolution images acquired during an ankle-tapping task. Our results revealed an average increase of 22% in %∆S (p=0.006) and 9% in decoding performance (p=0.015) with temporal resolution only at the highest spatial resolution of 1.5×1.5×1.5mm3, despite a 29% decrease in tSNR (p<0.001) and plateaued Z-scores. Further, the volume of significant activation was indifferent (p>0.05) across spatial resolution specifically at the highest temporal resolution of 500ms. These results demonstrate that the overall BOLD sensitivity can be increased significantly with temporal resolution, granted an adequately high spatial resolution with minimal physiological noise level. This shows the feasibility of diffuse motor-network imaging at high spatial and temporal resolution with robust BOLD sensitivity with 7T-fMRI. Importantly, we show that this sensitivity improvement could be extended to an fMRI application such as BCIs.
Collapse
Affiliation(s)
- Peter E Yoo
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia; Vascular Bionics Laboratory, Melbourne Brain Centre, Department of Medicine, The University of Melbourne, Victoria, Australia
| | - Sam E John
- Department of Electrical & Electronic Engineering, The University of Melbourne, Victoria, Australia; Vascular Bionics Laboratory, Melbourne Brain Centre, Department of Medicine, The University of Melbourne, Victoria, Australia; The Florey Institute of Neuroscience and Mental Health, 30 Royal Parade, Parkville, Victoria, Australia
| | - Shawna Farquharson
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia; Imaging Division, Florey Institute of Neuroscience and Mental Health, Melbourne Brain Centre, 245 Burgundy Street, Heidelberg, Melbourne, Victoria, Australia
| | - Jon O Cleary
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia
| | - Yan T Wong
- Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC 3800, Australia; Department of Physiology, Monash University, Clayton, VIC 3800, Australia; Biomedicine Discovery Institute, Monash University, Clayton, VIC 3800, Australia
| | - Amanda Ng
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia
| | - Claire B Mulcahy
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia; Imaging Division, Florey Institute of Neuroscience and Mental Health, Melbourne Brain Centre, 245 Burgundy Street, Heidelberg, Melbourne, Victoria, Australia
| | - David B Grayden
- Department of Electrical & Electronic Engineering, The University of Melbourne, Victoria, Australia; Vascular Bionics Laboratory, Melbourne Brain Centre, Department of Medicine, The University of Melbourne, Victoria, Australia; Center for Neural Engineering, The University of Melbourne, Victoria, Australia
| | - Roger J Ordidge
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia
| | - Nicholas L Opie
- Department of Electrical & Electronic Engineering, The University of Melbourne, Victoria, Australia; Vascular Bionics Laboratory, Melbourne Brain Centre, Department of Medicine, The University of Melbourne, Victoria, Australia; The Florey Institute of Neuroscience and Mental Health, 30 Royal Parade, Parkville, Victoria, Australia
| | - Terence J O'Brien
- Departments of Medicine and Neurology, Melbourne Brain Centre at The Royal Melbourne Hospital, The University of Melbourne, Melbourne, Victoria, Australia
| | - Thomas J Oxley
- Vascular Bionics Laboratory, Melbourne Brain Centre, Department of Medicine, The University of Melbourne, Victoria, Australia; The Florey Institute of Neuroscience and Mental Health, 30 Royal Parade, Parkville, Victoria, Australia; NeuroEngineering Laboratory, Department of Electrical &Electronic Engineering, The University of Melbourne, Melbourne, Victoria, Australia; Departments of Medicine and Neurology, Melbourne Brain Centre at The Royal Melbourne Hospital, The University of Melbourne, Melbourne, Victoria, Australia
| | - Bradford A Moffat
- Melbourne Brain Centre Imaging Unit, Department of Anatomy and Neuroscience, The University of Melbourne, Kenneth Myer Building 30 Royal Parade, Parkville, Victoria, Australia.
| |
Collapse
|
11
|
Towse TF, Elder CP, Bush EC, Klockenkemper SW, Bullock JT, Dortch RD, Damon BM. Post-contractile BOLD contrast in skeletal muscle at 7 T reveals inter-individual heterogeneity in the physiological responses to muscle contraction. NMR IN BIOMEDICINE 2016; 29:1720-1728. [PMID: 27753155 PMCID: PMC6594689 DOI: 10.1002/nbm.3593] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 06/29/2016] [Accepted: 07/06/2016] [Indexed: 05/13/2023]
Abstract
Muscle blood oxygenation-level dependent (BOLD) contrast is greater in magnitude and potentially more influenced by extravascular BOLD mechanisms at 7 T than it is at lower field strengths. Muscle BOLD imaging of muscle contractions at 7 T could, therefore, provide greater or different contrast than at 3 T. The purpose of this study was to evaluate the feasibility of using BOLD imaging at 7 T to assess the physiological responses to in vivo muscle contractions. Thirteen subjects (four females) performed a series of isometric contractions of the calf muscles while being scanned in a Philips Achieva 7 T human imager. Following 2 s maximal isometric plantarflexion contractions, BOLD signal transients ranging from 0.3 to 7.0% of the pre-contraction signal intensity were observed in the soleus muscle. We observed considerable inter-subject variability in both the magnitude and time course of the muscle BOLD signal. A subset of subjects (n = 7) repeated the contraction protocol at two different repetition times (TR : 1000 and 2500 ms) to determine the potential of T1 -related inflow effects on the magnitude of the post-contractile BOLD response. Consistent with previous reports, there was no difference in the magnitude of the responses for the two TR values (3.8 ± 0.9 versus 4.0 ± 0.6% for TR = 1000 and 2500 ms, respectively; mean ± standard error). These results demonstrate that studies of the muscle BOLD responses to contractions are feasible at 7 T. Compared with studies at lower field strengths, post-contractile 7 T muscle BOLD contrast may afford greater insight into microvascular function and dysfunction.
Collapse
Affiliation(s)
- Theodore F. Towse
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Physical Medicine and Rehabilitation, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Christopher P. Elder
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Emily C. Bush
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Samuel W. Klockenkemper
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jared T. Bullock
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Richard D. Dortch
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Bruce M. Damon
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University School of Engineering, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
| |
Collapse
|
12
|
Skouras S, Gray M, Critchley H, Koelsch S. Superficial amygdala and hippocampal activity during affective music listening observed at 3 T but not 1.5 T fMRI. Neuroimage 2014; 101:364-9. [DOI: 10.1016/j.neuroimage.2014.07.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 02/24/2014] [Accepted: 07/05/2014] [Indexed: 10/25/2022] Open
|
13
|
Mehemed TM, Fushimi Y, Okada T, Yamamoto A, Kanagaki M, Kido A, Fujimoto K, Sakashita N, Togashi K. Dynamic oxygen-enhanced MRI of cerebrospinal fluid. PLoS One 2014; 9:e100723. [PMID: 24956198 PMCID: PMC4067336 DOI: 10.1371/journal.pone.0100723] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Accepted: 05/29/2014] [Indexed: 11/18/2022] Open
Abstract
Oxygen causes an increase in the longitudinal relaxation rate of tissues through its T1-shortening effect owing to its paramagnetic properties. Due to such effects, MRI has been used to study oxygen-related signal intensity changes in various body parts including cerebrospinal fluid (CSF) space. Oxygen enhancement of CSF has been mainly studied using MRI sequences with relatively longer time resolution such as FLAIR, and T1 value calculation. In this study, fifteen healthy volunteers were scanned using fast advanced spin echo MRI sequence with and without inversion recovery pulse in order to dynamically track oxygen enhancement of CSF. We also focused on the differences of oxygen enhancement at sulcal and ventricular CSF. Our results revealed that CSF signal after administration of oxygen shows rapid signal increase in both sulcal CSF and ventricular CSF on both sequences, with statistically significant predominant increase in sulcal CSF compared with ventricular CSF. CSF is traditionally thought to mainly form from the choroid plexus in the ventricles and is absorbed at the arachnoid villi, however, it is also believed that cerebral arterioles contribute to the production and absorption of CSF, and controversy remains in terms of the precise mechanism. Our results demonstrated rapid oxygen enhancement in sulcal CSF, which may suggest inhaled oxygen may diffuse into sulcal CSF space rapidly probably due to the abundance of pial arterioles on the brain sulci.
Collapse
Affiliation(s)
- Taha M. Mehemed
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
- * E-mail:
| | - Tomohisa Okada
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Akira Yamamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Mitsunori Kanagaki
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Aki Kido
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Koji Fujimoto
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| | - Naotaka Sakashita
- Toshiba Medical Systems Corporation, MRI Systems Development Department Otawara-shi, Tochigi, Japan
| | - Kaori Togashi
- Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
| |
Collapse
|
14
|
Erhardt EB, Rachakonda S, Bedrick EJ, Allen EA, Adali T, Calhoun VD. Comparison of multi-subject ICA methods for analysis of fMRI data. Hum Brain Mapp 2011; 32:2075-95. [PMID: 21162045 PMCID: PMC3117074 DOI: 10.1002/hbm.21170] [Citation(s) in RCA: 555] [Impact Index Per Article: 39.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2010] [Revised: 08/09/2010] [Accepted: 08/27/2010] [Indexed: 11/08/2022] Open
Abstract
Spatial independent component analysis (ICA) applied to functional magnetic resonance imaging (fMRI) data identifies functionally connected networks by estimating spatially independent patterns from their linearly mixed fMRI signals. Several multi-subject ICA approaches estimating subject-specific time courses (TCs) and spatial maps (SMs) have been developed, however, there has not yet been a full comparison of the implications of their use. Here, we provide extensive comparisons of four multi-subject ICA approaches in combination with data reduction methods for simulated and fMRI task data. For multi-subject ICA, the data first undergo reduction at the subject and group levels using principal component analysis (PCA). Comparisons of subject-specific, spatial concatenation, and group data mean subject-level reduction strategies using PCA and probabilistic PCA (PPCA) show that computationally intensive PPCA is equivalent to PCA, and that subject-specific and group data mean subject-level PCA are preferred because of well-estimated TCs and SMs. Second, aggregate independent components are estimated using either noise-free ICA or probabilistic ICA (PICA). Third, subject-specific SMs and TCs are estimated using back-reconstruction. We compare several direct group ICA (GICA) back-reconstruction approaches (GICA1-GICA3) and an indirect back-reconstruction approach, spatio-temporal regression (STR, or dual regression). Results show the earlier group ICA (GICA1) approximates STR, however STR has contradictory assumptions and may show mixed-component artifacts in estimated SMs. Our evidence-based recommendation is to use GICA3, introduced here, with subject-specific PCA and noise-free ICA, providing the most robust and accurate estimated SMs and TCs in addition to offering an intuitive interpretation.
Collapse
|
15
|
Artifact quantification and tractography from 3T MRI after placement of aneurysm clips in subarachnoid hemorrhage patients. BMC Med Imaging 2011; 11:19. [PMID: 21970560 PMCID: PMC3198881 DOI: 10.1186/1471-2342-11-19] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2011] [Accepted: 10/04/2011] [Indexed: 12/29/2022] Open
Abstract
Background The application of advanced 3T MRI imaging techniques to study recovery after subarachnoid hemorrhage (SAH) is complicated by the presence of image artifacts produced by implanted aneurysm clips. To characterize the effect of these artifacts on image quality, we sought to: 1) quantify extent of image artifact in SAH patients with implanted aneurysm clips across a range of MR sequences typically used in studies of volumetry, blood oxygen level dependent signal change (BOLD-fMRI), and diffusion-weighted imaging (DW-MRI) and 2) to explore the ability to reconstruct white matter pathways in these patients. Methods T1- and T2-weighted structural, BOLD-fMRI, and DW-MRI scans were acquired at 3T in two patients with titanium alloy clips in ACOM and left ACA respectively. Intensity-based planimetric contouring was performed on aligned image volumes to define each artifact. Artifact volumes were quantified by artifact/clip length and artifact/brain volume ratios and analyzed by two-way (scan-by-rater) ANOVAs. Tractography pathways were reconstructed from DW-MRI at varying distances from the artifacts using deterministic methods. Results Artifact volume varied by MR sequence for length (p = 0.007) and volume (p < 0.001) ratios: it was smallest for structural images, larger for DW-MRI acquisitions, and largest on fMRI images. Inter-rater reliability was high (r = 0.9626, p < 0.0001), and reconstruction of white matter connectivity characteristics increased with distance from the artifact border. In both patients, reconstructed white matter pathways of the uncinate fasciculus and inferior fronto-occipital fasciculus were clearly visible within 2 mm of the artifact border. Conclusions Advanced 3T MR can successfully image brain tissue around implanted titanium aneurysm clips at different spatial ranges depending on sequence type. White matter pathways near clip artifacts can be reconstructed and visualized. These findings provide a reference for designing functional and structural neuroimaging studies of recovery in aSAH patients after clip placement.
Collapse
|
16
|
van de Giessen E, Groot PFC, Booij J, van den Brink W, Veltman DJ, Nederveen AJ. Functional MR imaging on an open 1T MR imaging system: exploiting the advantages of an open MR imaging system for functional MR imaging. AJNR Am J Neuroradiol 2011; 32:903-7. [PMID: 21330391 DOI: 10.3174/ajnr.a2383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Open MR imaging scanners are designed for imaging of specific patient groups that cannot be routinely scanned with conventional MR imaging scanners (eg, patients with obesity and claustrophobia). This study aims to determine whether BOLD sensitivity on an open 1T scanner is adequate for fMRI for diagnostic and research purposes by directly comparing fMRI results with a standard 3T MR imaging scanner. The optimal TE was also determined. MATERIALS AND METHODS Twelve healthy adults were scanned by using both an open 1T scanner and a standard 3T scanner. Gradient-echo echo-planar images were acquired for all subjects while performing motor and affective paradigms, each at 5 different TEs per scanner (range, 40-80 ms at open 1T; 20-40 ms at 3T). To compare BOLD sensitivity between scanners and TEs, we determined maximum statistical t scores per TE for all relevant brain areas (motor cortex, visual cortex, amygdala, and OFC) for individual subjects and group analyses. Additionally, T2* values were determined per scanner for the relevant brain areas. RESULTS Maximum t scores were significantly lower in the relevant brain areas on the open 1T compared with the 3T for single subjects but not for group analyses. The optimal TE for fMRI on an open 1T MR imaging system was found to be approximately 70 ms. CONCLUSIONS Although for single-subject studies as used in diagnostics, 3T was found to be superior, fMRI on an open 1T MR imaging scanner is suitable for research designed to analyze data at a group level.
Collapse
Affiliation(s)
- E van de Giessen
- Department of Nuclear Medicine, Academic Medical Center, University of Amsterdam, the Netherlands.
| | | | | | | | | | | |
Collapse
|
17
|
Conforto AB, Lois LA, Amaro E, Paes AT, Ecker C, Young WB, Gamarra LF, Peres MFP. Migraine and motion sickness independently contribute to visual discomfort. Cephalalgia 2011; 30:161-9. [PMID: 19500116 DOI: 10.1111/j.1468-2982.2009.01867.x] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The objective of this study was to evaluate, in patients with migraine and healthy volunteers, with and without a history of motion sickness, the degree of discomfort elicited by drifting striped patterns. Eighteen healthy volunteers (HV) and 30 migraine patients participated in the study. Discomfort was greater in migraine patients than in HV, and in individuals with a history of motion sickness than in those without, but the effect of history of migraine was independent of history of motion sickness. Generalized Estimating Equations models for binary correlated data revealed that these differences did not depend on levels of duty cycle, spatial and temporal frequencies. Visual discomfort in migraine patients was associated with worse performance. There was a significant correlation between median degree of discomfort across conditions and number of migraine attacks in the past month. Discomfort to drifting striped patterns may be related to central sensitization in migraine patients.
Collapse
Affiliation(s)
- A B Conforto
- Instituto Israelita de Ensino e Pesquisa Albert Einstein, São Paulo, Brazil.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Alvarez-Linera J. 3T MRI: advances in brain imaging. Eur J Radiol 2008; 67:415-26. [PMID: 18455895 DOI: 10.1016/j.ejrad.2008.02.045] [Citation(s) in RCA: 79] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2008] [Accepted: 02/27/2008] [Indexed: 11/28/2022]
Abstract
Since its approval by the FDA in 2000, brain MR imaging at 3.0 T has been increasingly used in clinical practice. Theoretically, the signal-to-noise ratio (SNR) of a 3T MR scanner will be double that of a 1.5 T scanner. However, the relationship between the magnetic field used and the image obtained is very complex. Today, using a 3T magnet in Neuroradiology has far more advantages than disadvantages, and the diagnostic potential of higher strength magnets for structural and vascular scans, diffusion and perfusion imaging, spectroscopy and cortical activation studies is improving. However, it is useful to have an awareness of how increasing field strength affects each of these techniques so that full advantage may be taken of them.
Collapse
Affiliation(s)
- Juan Alvarez-Linera
- Neuroradiology Section, Department of Radiology, Hospital Ruber Internacional, La Masó 38, Madrid 28034, Spain.
| |
Collapse
|
19
|
|
20
|
Tieleman A, Vandemaele P, Seurinck R, Deblaere K, Achten E. Comparison between functional magnetic resonance imaging at 1.5 and 3 Tesla: effect of increased field strength on 4 paradigms used during presurgical work-up. Invest Radiol 2007; 42:130-8. [PMID: 17220731 DOI: 10.1097/01.rli.0000251579.05052.08] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
OBJECTIVES We sought to evaluate the benefit of 3 T compared with 1.5 T during presurgical functional magnetic resonance imaging. MATERIALS AND METHODS Six participants performed a motor, a visual, and 2 language paradigms both at 1.5 and 3 T. The number of activated voxels, mean t-value, and assessment of language dominancy were compared between both field strengths. Group analysis was performed to evaluate the influence of field strength on the cortical language activation patterns. RESULTS The number of activated voxels and mean t-values were significantly higher at 3 T for all paradigms. Using the same statistical threshold, language activation was significantly less lateralized, and more activation zones were depicted at 3 T compared with 1.5 T. CONCLUSIONS Sensitivity associated with visual, motor and language functional magnetic resonance imaging increased significantly at 3 T. Additional cortical areas were depicted during language processing at 3 T. For assessment of language dominancy, usage of more stringent statistical thresholds at 3 T is suggested.
Collapse
Affiliation(s)
- Ann Tieleman
- Department of Radiology, Ghent Institute for functional Magnetic Resonance Imaging, GIfMI, Labaratory for Neuropsychology, Neurology Section, Ghent University Hospital, Ghent, Belgium.
| | | | | | | | | |
Collapse
|
21
|
Voss HU, Zevin JD, McCandliss BD. Functional MR imaging at 3.0 T versus 1.5 T: a practical review. Neuroimaging Clin N Am 2006; 16:285-97, x. [PMID: 16731367 DOI: 10.1016/j.nic.2006.02.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This article reviews and discusses recent findings in functional MRI at 1.5 and 3.0 T magnetic field strengths, in research and clinical applications. Particular attention is paid to comparative studies and to an explanation of the physical and biological dependencies leading to potential gains and tradeoffs of functional scanning at magnets with a high field strength.
Collapse
Affiliation(s)
- Henning U Voss
- Citigroup Biomedical Imaging Center, Weill Medical College of Cornell University, New York, NY 10021, USA.
| | | | | |
Collapse
|
22
|
Abstract
Medical images are created by detecting radiation probes transmitted through or emitted or scattered by the body. The radiation, modulated through interactions with tissues, yields patterns that provide anatomic and/or physiologic information. X-rays, gamma rays, radiofrequency signals, and ultrasound waves are the standard probes, but others like visible and infrared light, microwaves, terahertz rays, and intrinsic and applied electric and magnetic fields are being explored. Some of the younger technologies, such as molecular imaging, may enhance existing imaging modalities; however, they also, in combination with nanotechnology, biotechnology, bioinformatics, and new forms of computational hardware and software, may well lead to novel approaches to clinical imaging. This review provides a brief overview of the current state of image-based diagnostic medicine and offers comments on the directions in which some of its subfields may be heading.
Collapse
Affiliation(s)
- Anthony B Wolbarst
- Department of Radiation Medicine, Georgetown University Medical School, Washington, DC, USA
| | | |
Collapse
|