1
|
A novel co-culture assay to evaluate the effects of sympathetic innervation on vascular smooth muscle differentiation. Bioorg Chem 2023; 133:106233. [PMID: 36731293 DOI: 10.1016/j.bioorg.2022.106233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 10/24/2022] [Accepted: 10/27/2022] [Indexed: 11/22/2022]
Abstract
Dedifferentiation of vascular smooth muscle cells (VSMCs) from a functional phenotype to an inverse synthetic phenotype is a symptom of cardiovascular disorders, such as atherosclerosis and hypertension. The sympathetic nervous system (SNS) is an essential regulator of the differentiation of vascular smooth muscle cells (VSMCs). In addition, numerous studies suggest that SNS also stimulates VSMCs to retain their contractile phenotype. However, the molecular mechanisms for this stimulation have not been thoroughly studied. In this study, we used a novel in vitro co-culture method to evaluate the effective cellular interactions and stimulatory effects of sympathetic neurons on the differentiation of VSMCs. We co-cultured rat neural-like pheochromocytoma cells (PC12) and rat aortic VSMCs with this method. Expression of VSMCs contractile genes, including smooth muscle actin (acta2), myosin heavy chain (myh11), elastin (eln), and smoothelin (smtn), were determined by quantitative real-time-PCR analysis as an indicator of VSMCs differentiation. Fold changes for specific contractile genes in VSMCs grown in vitro for seven days in the presence (innervated) and absence (non-innervated) of sympathetic neurons were 3.5 for acta2, 6.5 for myh11, 4.19 for eln, and 4 for smtn (normalized to Tata Binding Protein (TBP)). As a result, these data suggest that sympathetic innervation promotes VSMCs' contractile gene expression and also maintains VSMCs' functional phenotype.
Collapse
|
2
|
Strongly Improving the Sensitivity of Phosphorescence-Based Optical Oxygen Sensors by Exploiting Nano-Porous Substrates. BIOSENSORS 2022; 12:bios12100774. [PMID: 36290912 PMCID: PMC9599114 DOI: 10.3390/bios12100774] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/10/2022] [Accepted: 09/15/2022] [Indexed: 05/21/2023]
Abstract
Sensitivity is one of the crucial factors in determining the quality of a fluorescence/phosphorescence-based gas sensor, and is estimated from the measurement of responses (I0/I, where I0 and I refer to the measured optical intensity of a sensor in absence and presence of analyte molecules) at various concentrations of analytes. In this work, we demonstrate phosphorescence-based optical oxygen sensors fabricated on highly porous anodic aluminum oxide (AAO) membranes showing dramatically high response. These sensors exploit the enormous surface area of the AAO to facilitate the effective interaction between the sensing molecules and the analytes. We spin-coat an AAO membrane (200 nm pore diameter) with a platinum-based oxygen sensing porphyrin dye, platinum(II) meso-tetrakis (pentafluorophenyl) porphyrin (PtTFPP), to fabricate a sensor exhibiting I0/I ~400 at 100% oxygen atmosphere. To address the generality of the AAO membrane, we fabricate a separate sensor with another porphyrin dye, platinum octaethylporphyrin (PtOEP), which exhibits an even higher I0/I of ~500. Both of these sensors offer the highest responses as an optical oxygen sensor hitherto reported. SEM and EDS analysis are performed to realize the effect of the increased surface area of the AAO membrane on the enhanced sensitivity.
Collapse
|
3
|
Effect of Collagen Nanofibers and Silanization on the Interaction of HaCaT Keratinocytes and 3T3 Fibroblasts with Alumina Nanopores. ACS APPLIED BIO MATERIALS 2021; 4:1852-1862. [DOI: 10.1021/acsabm.0c01538] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
4
|
"Hard" ceramics for "Soft" tissue engineering: Paradox or opportunity? Acta Biomater 2020; 115:1-28. [PMID: 32818612 DOI: 10.1016/j.actbio.2020.08.014] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 07/25/2020] [Accepted: 08/11/2020] [Indexed: 12/11/2022]
Abstract
Tissue engineering provides great possibilities to manage tissue damages and injuries in modern medicine. The involvement of hard biocompatible materials in tissue engineering-based therapies for the healing of soft tissue defects has impressively increased over the last few years: in this regard, different types of bioceramics were developed, examined and applied either alone or in combination with polymers to produce composites. Bioactive glasses, carbon nanostructures, and hydroxyapatite nanoparticles are among the most widely-proposed hard materials for treating a broad range of soft tissue damages, from acute and chronic skin wounds to complex injuries of nervous and cardiopulmonary systems. Although being originally developed for use in contact with bone, these substances were also shown to offer excellent key features for repair and regeneration of wounds and "delicate" structures of the body, including improved cell proliferation and differentiation, enhanced angiogenesis, and antibacterial/anti-inflammatory activities. Furthermore, when embedded in a soft matrix, these hard materials can improve the mechanical properties of the implant. They could be applied in various forms and formulations such as fine powders, granules, and micro- or nanofibers. There are some pre-clinical trials in which bioceramics are being utilized for skin wounds; however, some crucial questions should still be addressed before the extensive and safe use of bioceramics in soft tissue healing. For example, defining optimal formulations, dosages, and administration routes remain to be fixed and summarized as standard guidelines in the clinic. This review paper aims at providing a comprehensive picture of the use and potential of bioceramics in treatment, reconstruction, and preservation of soft tissues (skin, cardiovascular and pulmonary systems, peripheral nervous system, gastrointestinal tract, skeletal muscles, and ophthalmic tissues) and critically discusses their pros and cons (e.g., the risk of calcification and ectopic bone formation as well as the local and systemic toxicity) in this regard. STATEMENT OF SIGNIFICANCE: Soft tissues form a big part of the human body and play vital roles in maintaining both structure and function of various organs; however, optimal repair and regeneration of injured soft tissues (e.g., skin, peripheral nerve) still remain a grand challenge in biomedicine. Although polymers were extensively applied to restore the lost or injured soft tissues, the use of bioceramics has the potential to provides new opportunities which are still partially unexplored or at the very beginning. This reviews summarizes the state of the art of bioceramics in this field, highlighting the latest evolutions and the new horizons that can be opened by their use in the context of soft tissue engineering. Existing results and future challenges are discussed in order to provide an up-to-date contribution that is useful to both experienced scientists and early-stage researchers of the biomaterials community.
Collapse
|
5
|
Nano-porous anodic alumina: fundamentals and applications in tissue engineering. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2020; 31:60. [PMID: 32642974 DOI: 10.1007/s10856-020-06398-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2019] [Accepted: 06/25/2020] [Indexed: 06/11/2023]
Abstract
Recently, nanomaterials have been widely utilized in tissue engineering applications due to their unique properties such as the high surface to volume ratio and diversity of morphology and structure. However, most methods used for the fabrication of nanomaterials are rather complicated and costly. Among different nanomaterials, anodic aluminum oxide (AAO) is a great example of nanoporous structures that can easily be engineered by changing the electrolyte type, anodizing potential, current density, temperature, acid concentration and anodizing time. Nanoporous anodic alumina has often been used for mammalian cell culture, biofunctionalization, drug delivery, and biosensing by coating its surface with biocompatible materials. Despite its wide application in tissue engineering, thorough in vivo and in vitro studies of AAO are still required to enhance its biocompatibility and thereby pave the way for its application in tissue replacements. Recognizing this gap, this review article aims to highlight the biomedical potentials of AAO for applications in tissue replacements along with the mechanism of porous structure formation and pore characteristics in terms of fabrication parameters.
Collapse
|
6
|
Nanochannel-driven rapid capture of sub-nanogram level biomarkers for painless preeclampsia diagnosis. Biosens Bioelectron 2020; 163:112281. [PMID: 32568694 DOI: 10.1016/j.bios.2020.112281] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 04/28/2020] [Accepted: 05/06/2020] [Indexed: 12/28/2022]
Abstract
Preeclampsia (PE) is a pregnancy-specific hypertensive syndrome recognized as the leading cause of maternal and fetal morbidity and mortality worldwide. Painful blood-collection procedures or low accuracy of non-invasive approaches require faster, patient-friendly, and more sensitive diagnostic technologies. Here we report a painless, highly sensitive detection platform using nanoporous microneedles (nMNs) that enables rapid capture of biomarkers present at sub-nanogram levels. The highly porous nanostructures on the nMN surface were prepared by anodization of aluminum MN and then functionalized by immobilization of capture antibodies to detect target biomarkers based on an immunoassay method. The immuno-functionalized nMN array demonstrated rapid capture of an estrogen (E2) biomarker for PE following a 1-min incubation and exhibited a concentration-dependent change in fluorescence intensity over the E2 range of 0.5 ng mL-1 to 1000 ng mL-1 after treatment with fluorescence-detection antibodies. Remarkably, the nMN patch selectively detected sub-nanogram-levels of E2 in subcutaneous interstitial fluid from rats with increased diagnostic accuracy as compared with commercial immunoassay kits. This bio-functionalized nMN platform showed improved biosensing capability for multiple PE-related biomarkers, including hormones and proteins. Furthermore, this painless method demonstrated efficacy as a point-of-need diagnostic platform using portable smartphone-based fluorescence microscope to obtain fluorescence images of biomarker-captured nMN arrays.
Collapse
|
7
|
Bioconjugation strategy for cell surface labelling with gold nanostructures designed for highly localized pH measurement. Nat Commun 2018; 9:5278. [PMID: 30538244 PMCID: PMC6290020 DOI: 10.1038/s41467-018-07726-5] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 11/20/2018] [Indexed: 01/08/2023] Open
Abstract
Regulation of intracellular pH is critically important for many cellular functions. The quantification of proton extrusion in different types of cells and physiological conditions is pivotal to fully elucidate the mechanisms of pH homeostasis. Here we show the use of gold nanoparticles (AuNP) to create a high spatial resolution sensor for measuring extracellular pH in proximity of the cell membrane. We test the sensor on HepG2 liver cancer cells and MKN28 gastric cancer cells before and after inhibition of Na+/H+ exchanger. The gold surface conjugation strategy is conceived with a twofold purpose: i) to anchor the AuNP to the membrane proteins and ii) to quantify the local pH from AuNP using surface enhanced Raman spectroscopy (SERS). The nanometer size of the cell membrane anchored sensor and the use of SERS enable us to visualize highly localized variation of pH induced by H+ extrusion, which is particularly upregulated in cancer cells. Understanding the pH changes at cell surfaces is important for understanding the mechanisms of different physiological processes. Here, the authors report on the development of a cell membrane anchored gold nanoparticle for surface enhanced Raman spectroscopy determination of pH.
Collapse
|
8
|
A comparative study of the effect of submicron porous and smooth ultrafine-grained Ti-20Mo surfaces on osteoblast responses. J Biomed Mater Res A 2018; 106:2020-2033. [PMID: 29569836 DOI: 10.1002/jbm.a.36402] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 02/20/2018] [Accepted: 03/15/2018] [Indexed: 11/08/2022]
Abstract
The surface of an orthopaedic implant plays a crucial role in determining the adsorption of proteins and cell functions. A detailed comparative study has been made of the in vitro osteoblast responses to coarse-grained (grain size: 500 μm), ultrafine-grained (grain size: 100 nm), coarse-porous (pore size: 350 nm), and fine-porous (pore size: 155 nm) surfaces of Ti-20Mo alloy. The purpose was to provide essential experimental data for future design of orthopaedic titanium implants for rapid osseointegration. Systematic original experimental data was produced for each type of surfaces in terms of surface wettability, cell morphology, adhesion, growth, and differentiation. Microscopic evidence was collected to reveal the detailed interplay between each characteristic surface with proteins or cells. Various new observations were discussed and compared with literature data. It was concluded that the coarse-porous surfaces offered the optimum topographical environment for osteoblasts and that the combination of ultrafine grains and considerable grain boundary areas is not an effective way to enhance cell growth and osteogenic capacity. Moreover, pore features (size and depth) have a greater effect than smooth surfaces on cell growth and osteogenic capacity. It proves that cells can discern the difference in pore size in the range of 100-350 nm. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2020-2033, 2018.
Collapse
|
9
|
Viability Studies of Cells on Nanostructured Surfaces With Various Feature Sizes. B KOREAN CHEM SOC 2017. [DOI: 10.1002/bkcs.11325] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
10
|
Aluminum Templates of Different Sizes with Micro-, Nano- and Micro/Nano-Structures for Cell Culture. COATINGS 2017. [DOI: 10.3390/coatings7110179] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Controlling cell growth with tailorable 2D nanoholes arrays. J Colloid Interface Sci 2016; 466:150-61. [DOI: 10.1016/j.jcis.2015.12.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Revised: 12/08/2015] [Accepted: 12/08/2015] [Indexed: 11/17/2022]
|
12
|
Nanostructured surface of electrospun PCL/dECM fibres treated with oxygen plasma for tissue engineering. RSC Adv 2016. [DOI: 10.1039/c6ra03840a] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Nanoscale patterns on the surface of PCL-based dECM were developed by a selective plasma treatment.
Collapse
|
13
|
Nanoporous Anodic Alumina for Drug Delivery and Biomedical Applications. NANOPOROUS ALUMINA 2015. [DOI: 10.1007/978-3-319-20334-8_11] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
14
|
DODAB:monoolein liposomes containing Candida albicans cell wall surface proteins: A novel adjuvant and delivery system. Eur J Pharm Biopharm 2015; 89:190-200. [DOI: 10.1016/j.ejpb.2014.11.028] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2014] [Revised: 11/28/2014] [Accepted: 11/29/2014] [Indexed: 11/26/2022]
|
15
|
Abstract
The aim of this study was to prepare different sized porous anodic alumina (PAA) and examine preosteoblast (MC3T3-E1) attachment and proliferation on such nanoporous surfaces. In this study, PAA with tunable pore sizes (25 nm, 50 nm, and 75 nm) were fabricated by a two-step anodizing procedure in oxalic acid. The surface morphology and elemental composition of PAA were characterized by field emission scanning electron microscopy and X-ray photoelectron spectroscopy analysis. The nanopore arrays on all of the PAA samples were highly regular. X-ray photoelectron spectroscopy analysis suggested that the chemistry of PAA and flat aluminum surfaces were similar. However, contact angles were significantly greater on all of the PAA compared to flat aluminum substrates, which consequently altered protein adsorption profiles. The attachment and proliferation of preosteoblasts were determined for up to 7 days in culture using field emission scanning electron microscopy and a Cell Counting Kit-8. Results showed that nanoporous surfaces did not enhance initial preosteoblast attachment, whereas preosteoblast proliferation dramatically increased when the PAA pore size was either 50 nm or 75 nm compared to all other samples (P<0.05). Thus, this study showed that one can alter surface energy of aluminum by modifying surface nano-roughness alone (and not changing chemistry) through an anodization process to improve osteoblast density, and, thus, should be further studied as a bioactive interface for orthopedic applications.
Collapse
|
16
|
A mini-review: Cell response to microscale, nanoscale, and hierarchical patterning of surface structure. J Biomed Mater Res B Appl Biomater 2014; 102:1580-94. [DOI: 10.1002/jbm.b.33158] [Citation(s) in RCA: 145] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Revised: 03/04/2014] [Accepted: 03/13/2014] [Indexed: 12/17/2022]
|
17
|
The effect of physical and chemical cues on hepatocellular function and morphology. Int J Mol Sci 2014; 15:4299-317. [PMID: 24619224 PMCID: PMC3975399 DOI: 10.3390/ijms15034299] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Revised: 02/14/2014] [Accepted: 02/25/2014] [Indexed: 12/24/2022] Open
Abstract
Physical topographical features and/or chemical stimuli to the extracellular matrix (ECM) provide essential cues that manipulate cell functions. From the physical point of view, contoured nanostructures are very important for cell behavior in general, and for cellular functions. From the chemical point of view, ECM proteins containing an RGD sequence are known to alter cell functions. In this study, the influence of integrated physical and chemical cues on a liver cell line (HepG2) was investigated. To mimic the physical cues provided by the ECM, amorphous TiO2 nanogratings with specific dimensional and geometrical characteristics (nanogratings 90 nm wide and 150 nm apart) were fabricated. To mimic the chemical cues provided by the ECM, the TiO2 inorganic film was modified by immobilization of the RGD motif. The hepatic cell line morphological and functional changes induced by simultaneously combining these diversified cues were investigated, including cellular alignment and the expression of different functional proteins. The combination of nanopatterns and surface modification with RGD induced cellular alignment and expression of functional proteins, indicating that physical and chemical cues are important factors for optimizing hepatocyte function.
Collapse
|
18
|
Stability of (bio)functionalized porous aluminum oxide. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:1311-1320. [PMID: 24471580 DOI: 10.1021/la403525z] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Porous aluminum oxide (PAO), a nanostructured support for, among others, culturing microorganisms, was chemically modified in order to attach biomolecules that can selectively interact with target bacteria. We present the first comprehensive study of monolayer-modified PAO using conditions that are relevant to microbial growth with a range of functional groups (carboxylic acid, α-hydroxycarboxylic acid, alkyne, alkene, phosphonic acid, and silane). Their stability was initially assessed in phosphate-buffered saline (pH 7.0) at room temperature. The most stable combination (PAO with phosphonic acids) was further studied over a range of physiological pHs (4-8) and temperatures (up to 80 °C). Varying the pH had no significant effect on the stability, but it gradually decreased with increasing temperature. The stability of phosphonic acid-modified PAO surfaces was shown to depend strongly on the other terminal group of the monolayer structure: in general, hydrophilic monolayers were less stable than hydrophobic monolayers. Finally, an alkyne-terminated PAO surface was reacted with an azide-linked mannose derivative. The resulting mannose-presenting PAO surface showed the clearly increased adherence of a mannose-binding bacterium, Lactobacillus plantarum, and also allowed for bacterial outgrowth.
Collapse
|
19
|
Chemical synthesis, characterisation, and biocompatibility of nanometre scale porous anodic aluminium oxide membranes for use as a cell culture substrate for the vero cell line: a preliminary study. BIOMED RESEARCH INTERNATIONAL 2014; 2014:238762. [PMID: 24579077 PMCID: PMC3918858 DOI: 10.1155/2014/238762] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Accepted: 11/11/2013] [Indexed: 11/17/2022]
Abstract
In this preliminary study we investigate for the first time the biomedical potential of using porous anodic aluminium oxide (AAO) membranes as a cell substrate for culturing the Cercopithecus aethiops (African green monkey) Kidney (Vero) epithelial cell line. One advantage of using the inorganic AAO membrane is the presence of nanometre scale pore channels that allow the exchange of molecules and nutrients across the membrane. The size of the pore channels can be preselected by adjusting the controlling parameters of a temperature controlled two-step anodization process. The cellular interaction and response of the Vero cell line with an in-house synthesised AAO membrane, a commercially available membrane, and a glass control were assessed by investigating cell adhesion, morphology, and proliferation over a 72 h period. The number of viable cells proliferating over the respective membrane surfaces revealed that the locally produced in-house AAO membrane had cells numbers similar to the glass control. The study revealed evidence of focal adhesion sites over the surface of the nanoporous membranes and the penetration of cellular extensions into the pore structure as well. The outcome of the study has revealed that nanometre scale porous AAO membranes have the potential to become practical cell culture scaffold substrates with the capability to enhance adhesion and proliferation of Vero cells.
Collapse
|
20
|
Induction of hepatocyte functional protein expression by submicron/nano-patterning substrates to mimic in vivo structures. Biomater Sci 2014; 2:330-338. [DOI: 10.1039/c3bm60191a] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
21
|
Effect of the nanostructure of porous alumina on growth behavior of MG63 osteoblast-like cells. J Biosci Bioeng 2013; 116:509-15. [DOI: 10.1016/j.jbiosc.2013.04.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2013] [Accepted: 04/03/2013] [Indexed: 10/26/2022]
|
22
|
In vitro proliferation and osteogenic differentiation of mesenchymal stem cells on nanoporous alumina. Int J Nanomedicine 2013; 8:2745-56. [PMID: 23935364 PMCID: PMC3735283 DOI: 10.2147/ijn.s44885] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Cell adhesion, migration, and proliferation are significantly affected by the surface topography of the substrates on which the cells are cultured. Alumina is one of the most popular implant materials used in orthopedics, but few data are available concerning the cellular responses of mesenchymal stem cells (MSCs) grown on nanoporous structures. MSCs were cultured on smooth alumina substrates and nanoporous alumina substrates to investigate the interaction between surface topographies of nanoporous alumina and cellular behavior. Nanoporous alumina substrates with pore sizes of 20 nm and 100 nm were used to evaluate the effect of pore size on MSCs as measured by proliferation, morphology, expression of integrin β1, and osteogenic differentiation. An MTT assay was used to measure cell viability of MSCs on different substrates, and determined that cell viability decreased with increasing pore size. Scanning electron microscopy was used to investigate the effect of pore size on cell morphology. Extremely elongated cells and prominent cell membrane protrusions were observed in cells cultured on alumina with the larger pore size. The expression of integrin β1 was enhanced in MSCs cultured on porous alumina, revealing that porous alumina substrates were more favorable for cell growth than smooth alumina substrates. Higher levels of osteoblastic differentiation markers such as alkaline phosphatase, osteocalcin, and mineralization were detected in cells cultured on alumina with 100 nm pores compared with cells cultured on alumina with either 20 nm pores or smooth alumina. This work demonstrates that cellular behavior is affected by variation in pore size, providing new insight into the potential application of this novel biocompatible material for the developing field of tissue engineering.
Collapse
|
23
|
FIB preparation and SEM investigations for three-dimensional analysis of cell cultures on microneedle arrays. SCANNING 2012; 34:221-229. [PMID: 22076793 DOI: 10.1002/sca.20297] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2011] [Accepted: 09/23/2011] [Indexed: 05/31/2023]
Abstract
We report the investigation of the interfaces between microneedle arrays and cell cultures in patch-on-chip systems by using Focused Ion Beam (FIB) preparation and Scanning Electron Microscopy (SEM). First, FIB preparations of micro chips are made to determine the size and shape of the designed microneedles. In this essay, we investigate the cell-substrate interaction, especially the cell adhesion, and the microneedle's potential cell penetration. For this purpose, cross-sectional preparation of these hard/soft hybrid structures is performed by the FIB technology. By applying the FIB technology followed by high-resolution imaging with SEM, new insights into the cell-substrate interface can be received. One can clearly distinguish between cells that are only in contact with microneedles and cells that are penetrated by microneedles. A stack of slice images is collected by the application of the slice-and-view setup during FIB preparation and is used for three-dimensional reconstruction of cells and micro-needles.
Collapse
|
24
|
Self-supporting nanoporous alumina membranes as substrates for hepatic cell cultures. J Biomed Mater Res A 2012; 100:2230-8. [PMID: 22492687 DOI: 10.1002/jbm.a.34158] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2012] [Revised: 02/26/2012] [Accepted: 02/28/2012] [Indexed: 11/10/2022]
Abstract
Membranes made from nanoporous alumina exhibit interesting properties for their use in biomedical research. They show high porosity and the pore diameters can be easily adjusted in a reproducible manner. Nanoporous alumina membranes are thus ideal substrates for the cultivation of polar cells (e.g., hepatocytes) or the establishment of indirect co-cultures. The porous nature of the material allows supply of nutrients to both sides of adherent cells and the exchange of molecules across the membrane. However, it is well-known that surface features in the nanometer range affect cellular behavior. In this study, the response of HepG2 cells to nanoporous alumina membranes with three different pore diameters, ranging from 50 to 250 nm, has been evaluated. The cellular interactions with the nanoporous materials were assessed by investigating cell adhesion, morphology, and proliferation. Cell functionality was measured by means of albumin production. The membranes supported good cell adhesion and spreading. Compared to tissue culture plastic, the cells on the porous substrates developed distinct focal adhesion sites and actin stress fibers. Additionally, electron microscopical investigations revealed the penetration of cellular extensions into pores with diameters bigger than 200 nm. Furthermore, cell proliferation significantly increased with an increase in pore diameter, whereas the albumin production followed a reverse trend. Thus, it seems to be possible to direct cellular behavior of HepG2 cells growing on nanoporous alumina by changing the pore diameter of the material. Hence, nanoporous alumina membranes can be useful culture substrates to develop new approaches in the field of liver tissue engineering.
Collapse
|
25
|
Physical characterization of thin semi-porous poly(L-lactic acid)/poly(ethylene glycol) membranes for tissue engineering. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 18:1321-33. [DOI: 10.1163/156856207782177864] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
26
|
The effect of nano-scale topography on keratinocyte phenotype and wound healing following burn injury. Tissue Eng Part A 2011; 18:703-14. [PMID: 21988618 DOI: 10.1089/ten.tea.2011.0307] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Topographic modulation of tissue response is an important consideration in the design and manufacture of a biomaterial. In developing new tissue therapies for skin, all levels of architecture, including the nanoscale need to be considered. Here we show that keratinocyte phenotype is affected by nanoscale changes in topography with cell morphology, proliferation, and migration influenced by the pore size in anodic aluminum oxide membranes. A membrane with a pore size of 300 nm, which enhanced cell phenotype in vitro, was used as a dressing to cover a partial thickness burn injury in the pig. Wounds dressed with the membrane showed evidence of advanced healing with significantly less organizing granulation tissue and more mature epidermal layers than control wounds dressed with a standard burns dressing. The results demonstrate the importance of nanoscale topography in modulating keratinocyte phenotype and skin wound healing.
Collapse
|
27
|
Investigation of cell-substrate interactions by focused ion beam preparation and scanning electron microscopy. Acta Biomater 2011; 7:2499-507. [PMID: 21345385 DOI: 10.1016/j.actbio.2011.02.024] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2010] [Revised: 01/21/2011] [Accepted: 02/15/2011] [Indexed: 11/30/2022]
Abstract
Cell-substrate interactions, which are an important issue in tissue engineering, have been studied using focused ion beam (FIB) milling and scanning electron microscopy (SEM). Sample cross-sections were generated at predefined positions (target preparation) to investigate the interdependency of growing cells and the substrate material. The experiments focus on two cell culturing systems, hepatocytes (HepG2) on nanoporous aluminum oxide (alumina) membranes and mouse fibroblasts (L929) and primary nerve cells on silicon chips comprised of microneedles. Cross-sections of these soft/hard hybrid systems cannot be prepared by conventional techniques like microtomy. Morphological investigations of hepatocytes growing on nanoporous alumina membranes demonstrate that there is in-growth of microvilli from the cell surface into porous membranes having pore diameters larger than 200 nm. Furthermore, for various cell cultures on microneedle arrays contact between the cells and the microneedles can be observed at high resolution. Based on FIB milled cross-sections and SEM micrographs cells which are only in contact with microneedles and cells which are penetrated by microneedles can be clearly distinguished. Target preparation of biological samples by the FIB technique especially offers the possibility of preparing not only soft materials but also hybrid samples (soft/hard materials). Followed by high resolution imaging by SEM, new insights into cell surface interactions can be obtained.
Collapse
|
28
|
Micropatterning of a nanoporous alumina membrane with poly(ethylene glycol) hydrogel to create cellular micropatterns on nanotopographic substrates. Acta Biomater 2011; 7:1281-9. [PMID: 21056702 DOI: 10.1016/j.actbio.2010.11.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2010] [Revised: 09/28/2010] [Accepted: 11/02/2010] [Indexed: 10/18/2022]
Abstract
In this paper, we describe a simple method for fabricating micropatterned nanoporous substrates that are capable of controlling the spatial positioning of mammalian cells. Micropatterned substrates were prepared by fabricating poly(ethylene glycol) (PEG) hydrogel microstructures on alumina membranes with 200 nm nanopores using photolithography. Because hydrogel precursor solution could infiltrate and become crosslinked within the nanopores, the resultant hydrogel micropatterns were firmly anchored on the substrate without the use of adhesion-promoting monolayers, thereby allow tailoring of the surface properties of unpatterned nanoporous areas. For mammalian cell patterning, arrays of microwells of different dimensions were fabricated. These microwells were composed of hydrophilic PEG hydrogel walls surrounding nanoporous bottoms that were modified with cell-adhesive Arg-Gly-Asp (RGD) peptides. Because the PEG hydrogel was non-adhesive towards proteins and cells, cells adhered selectively and remained viable within the RGD-modified nanoporous regions, thereby creating cellular micropatterns. Although the morphology of cell clusters and the number of cells inside one microwell were dependent on the lateral dimension of the microwells, adhered cells that were in direct contact with nanopores were able to penetrate into the nanopores by small extensions (filopodia) for all the different sizes of microwells evaluated.
Collapse
|
29
|
Abstract
AbstractFor the investigation of the adhesion of mammalian cells on a semiconductor biosensor structure, nerve cells on silicon neurochips were prepared for scanning electron microscopy investigations (SEM) and cross-sectional preparation by focused ion beam technology (FIB). The cross-sectional pattern demonstrates the focal adhesion points of the nerve cells on the chip. Finally, SEM micrographs were taken parallel to the FIB ablation to investigate the cross section of the cells slice by slice in order to demonstrate the spatial distribution of focal contact positions for a possible three-dimensional reconstruction of the cell-silicon interface.
Collapse
|
30
|
Progress in Nano-Engineered Anodic Aluminum Oxide Membrane Development. MATERIALS 2011; 4:487-526. [PMID: 28880002 PMCID: PMC5448500 DOI: 10.3390/ma4030487] [Citation(s) in RCA: 105] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2011] [Revised: 02/17/2011] [Accepted: 02/22/2011] [Indexed: 11/16/2022]
Abstract
The anodization of aluminum is an electro-chemical process that changes the surface chemistry of the metal, via oxidation, to produce an anodic oxide layer. During this process a self organized, highly ordered array of cylindrical shaped pores can be produced with controllable pore diameters, periodicity and density distribution. This enables anodic aluminum oxide (AAO) membranes to be used as templates in a variety of nanotechnology applications without the need for expensive lithographical techniques. This review article is an overview of the current state of research on AAO membranes and the various applications of nanotechnology that use them in the manufacture of nano-materials and devices or incorporate them into specific applications such as biological/chemical sensors, nano-electronic devices, filter membranes and medical scaffolds for tissue engineering.
Collapse
|
31
|
Significance of novel bioinorganic anodic aluminum oxide nanoscaffolds for promoting cellular response. Nanotechnol Sci Appl 2011; 4:11-24. [PMID: 24198483 DOI: 10.2147/nsa.s13913] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Tissue engineering is a multidisciplinary field that can directly benefit from the many advancements in nanotechnology and nanoscience. This article reviews a novel biocompatible anodic aluminum oxide (AAO, alumina) membrane in terms of tissue engineering. Cells respond and interact with their natural environment, the extracellular matrix, and the landscape of the substrate. The interaction with the topographical features of the landscape occurs both in the micrometer and nanoscales. If all these parameters are favorable to the cell, the cell will respond in terms of adhesion, proliferation, and migration. The role of the substrate/scaffold is crucial in soliciting a favorable response from the cell. The size and type of surface feature can directly influence the response and behavior of the cell. In the case of using an AAO membrane, the surface features and porosity of the membrane can be dictated at the nanoscale during the manufacturing stage. This is achieved by using general laboratory equipment to perform a relatively straightforward electrochemical process. During this technique, changing the operational parameters of the process directly controls the nanoscale features produced. For example, the pore size, pore density, and, hence, density can be effectively controlled during the synthesis of the AAO membrane. In addition, being able to control the pore size and porosity of a biomaterial such as AAO significantly broadens its application in tissue engineering.
Collapse
|
32
|
The potential of nanoporous anodic aluminium oxide membranes to influence skin wound repair. Tissue Eng Part A 2010; 15:3753-63. [PMID: 19527180 DOI: 10.1089/ten.tea.2008.0594] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Cells respond to changes in the environment by altering their phenotype. The ability to influence cell behavior by modifying their environment provides an opportunity for therapeutic application, for example, to promote faster wound healing in response to skin injury. Here, we have modified the preparation of an aluminium oxide template to generate large uniform membranes with differing nano-pore sizes. Epidermal cells (keratinocytes) and dermal cells (fibroblasts) readily adhere to these nanoporous membranes. The pore size appears to influence the rate of cell proliferation and migration, important aspects of cell behavior during wound healing. The suitability of the membrane to act as a dressing after a burn injury was assessed in vivo; application of the membrane demonstrated adherence and conformability to the skin surface of a pig, with no observed degradation or detrimental effect on the repair. Our results suggest that keratinocytes are sensitive to changes in topography at the nanoscale level and that this property may be exploited to improve wound repair after tissue injury.
Collapse
|
33
|
|
34
|
Nanoporous aluminum oxide membranes for filtration and biofunctionalization. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2007; 3:1032-40. [PMID: 17492744 DOI: 10.1002/smll.200600582] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Nanoporous aluminum oxide membranes with high open porosity are prepared by anodic oxidation. Conventional self-supporting as well as mechanically stabilized nanoporous membranes are produced from aluminum plates and microimprinted aluminum foils, respectively. The mechanically stabilized membranes are characterized by very thin membrane parts stabilized by surrounding thick bridges. The minimal thickness of these thin membranes with open pores on both sides is 1 microm, with a mean pore size of the parallel open pores of 185 nm. With these two kinds of membrane the flow rates for cross filtration can be tuned over a wide range. With the mechanically stabilized membranes, substantially higher flow rates are achieved and experiments that cannot be performed with thicker membranes become possible. The biofunctionalization of the pore walls with archaebacterial tetraether lipids is realized and proved using aminated semiconductor nanocrystals. The lipid layer deposited on the pore walls also changes the filtration properties.
Collapse
|