1
|
He X, Xie C. Experimental and Simulation Study of the Effect of Plastic Residual Strain on the Electrochemical Corrosion of Biomagnesium Alloys. MATERIALS (BASEL, SWITZERLAND) 2025; 18:2482. [PMID: 40508480 PMCID: PMC12156182 DOI: 10.3390/ma18112482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2025] [Revised: 05/22/2025] [Accepted: 05/22/2025] [Indexed: 06/16/2025]
Abstract
In this study, the effect of plastic residual strain on the corrosion behavior of ZK60 magnesium alloy was systematically revealed using a research method combining experimental characterization and numerical simulation. Based on the multiphysical field coupling theory, a numerical model containing deformation field, corrosion phase field, and material transfer field was constructed, and the dynamic simulation of plastic residual strain-induced corrosion damage was successfully realized. Tafel polarization curves obtained from electrochemical tests were fitted to the key parameters of the secondary current distribution. The kinetic parameter L controlling the corrosion rate in the phase-field model was innovatively determined by the inverse calibration method, and a quantitative relationship between the kinetics of electrochemical corrosion and the phase-field theory was established. The corrosion depth distribution of the pre-strained specimens is quantitatively characterized and the results are in agreement with the finite element simulation results. The coupled strain-corrosion analysis method proposed in this study provides a theoretical basis for the design and life prediction of corrosion resistance of components under complex stress states.
Collapse
Affiliation(s)
| | - Chao Xie
- Faculty of Mechanical Engineering and Mechanics, Ningbo University, Ningbo 315211, China;
| |
Collapse
|
2
|
Tong X, Shen X, Lin Z, Zhou R, Han Y, Zhu L, Huang S, Ma J, Li Y, Wen C, Lin J. In situ phosphorus-modified Mg 2Ge/Zn-Cu composite with improved mechanical, degradation, biotribological properties, and in vitro and in vivo osteogenesis and osteointegration performance for biodegradable bone-implant applications. Bioact Mater 2025; 43:491-509. [PMID: 40115880 PMCID: PMC11923437 DOI: 10.1016/j.bioactmat.2024.09.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 08/13/2024] [Accepted: 09/18/2024] [Indexed: 03/23/2025] Open
Abstract
Zinc (Zn)-based composites are promising biodegradable bone-implant materials because of their good biocompatibility, processability, and biodegradability. Nevertheless, the low interfacial bonding strength, coordinated deformation capacity, and mechanical strength of current Zn-based composites hinder their clinical application. In this study, we developed a biodegradable in situ 4Mg2Ge/Zn-0.3Cu-0.05P composite (denoted ZMGCP) via phosphorus (P) modification and hot-rolling for bone-implant applications. The mechanical properties, corrosion behavior, biotribological performance, in vitro cytocompatibility and osteogenic differentiation, and in vivo osteogenesis and osteointegration of the as-cast (AC) and hot-rolled (HR) ZMGCP samples were systematically evaluated and compared to those of 4Mg2Ge/Zn-0.3Cu (denoted ZMGC). The primary and eutectic reinforcement Mg2Ge phases formed during solidification were refined after P modification and hot-rolling. The HR ZMGCP exhibited the best tensile properties among all the samples with an ultimate tensile strength of 288.9 MPa, a yield strength of 194.5 MPa, and an elongation of 17.7 %. The HR ZMGCP showed the lowest corrosion rate of 336 μm/a, 186 μm/a, and 61.7 μm/a as measured by potentiodynamic polarization, electrochemical impedance spectroscopy, and immersion testing, respectively, among all the samples in Hanks' solution. The HR ZMGCP also showed higher biotribological resistance than its ZMGC counterpart. The HR ZMGCP exhibited the highest in vitro cytocompatibility, the best osteogenesis capability and angiogenesis property among the HR samples of pure Zn, ZMGC, and ZMGCP. Furthermore, the HR ZMGCP displayed complete in vivo biocompatibility, osteogenesis, osteointegration capability, and an appropriate degradation rate, showing significant potential for a biodegradable bone-implant material.
Collapse
Affiliation(s)
- Xian Tong
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
- School of Materials Science and Engineering, Xiangtan University, Xiangtan, 411105, China
| | - Xinkun Shen
- Science and Education Division, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Wenzhou, 325016, China
| | - Zhiqiang Lin
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
| | - Runqi Zhou
- Chongqing Key Laboratory of Oral Disease and Biomedical Sciences and Chongqing Municipal Key Laboratory of Oral Biomedical Engineering, Higher Education and Stomatological Hospital, Chongqing Medical University, Chongqing, 401174, China
| | - Yue Han
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
| | - Li Zhu
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
| | - Shengbin Huang
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
| | - Jianfeng Ma
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
| | - Yuncang Li
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne, Victoria, 3001, Australia
| | - Jixing Lin
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou, 325027, China
| |
Collapse
|
3
|
Lu C, Song C, Yu Y, Yang L, Zheng W, Luo F, Xiao Y, Luo J, Xu J. Biodegradable zinc alloys with high strength and suitable mechanical integrity as bone repair metals. Sci Rep 2024; 14:30558. [PMID: 39702751 DOI: 10.1038/s41598-024-78842-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Accepted: 11/04/2024] [Indexed: 12/21/2024] Open
Abstract
Mechanical properties and integrity of biodegradable Zn alloys during degradation holds significant importance. In this study, a Zn-Mg-Mn alloy with tensile strength of 414 MPa and an elongation of 26% was developed. The strength contributions of as-extruded Zn alloy from grain boundary strengthening, precipitation strengthening, and second phase strengthening. Degradation of the Zn alloy in Hank's solution exhibited a decreasing trend with prolonged immersion, eventually stabilizing at 16 μm/year. Corrosion morphology analysis revealed that the corrosion modes transformed from pitting corrosion to severely localized corrosion with prolonged immersion time, eventually lead to formation of large holes. Although the tensile strength of the Zn alloys remained relatively unchanged following varied immersion time, a substantial decrease in elongation was observed. The decreased elongation primarily attributed to the formation of surface corrosion pits or holes, exacerbating crack propagation during tension. Biocompatibility assessments of Zn alloys demonstrated that a 50% concentration of Zn alloy leach solution cultured with C3H10 and RMSC cells yielded cellular activity exceeding 80%, indicating excellent cytocompatibility. Alkaline phosphatase (ALP) and alizarin red staining results further underscored the remarkable early and late osteogenic properties exhibited by Zn-Mg-Mn alloy.
Collapse
Affiliation(s)
- Chengwu Lu
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Nanping First Hospital Affiliated to Fujian Medical University, Nanping, 353000, China
| | - Chao Song
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China
| | - Yunlong Yu
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China
| | - Linhai Yang
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China
| | - Wu Zheng
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China
| | - Fenqi Luo
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China
| | - Yuhua Xiao
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China
| | - Jun Luo
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China.
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China.
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China.
| | - Jie Xu
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350000, China.
- Department of Orthopedics, Fujian Provincial Hospital, Fujian Medical University, Fuzhou, 350000, China.
- Fuzhou University Affiliated Provincial Hospital, Fuzhou, 350000, China.
| |
Collapse
|
4
|
Palai D, Roy T, De A, Mukherjee S, Bandyopadhyay S, Dhara S, Das S, Das K. Study on the Bioactivity Response of the Newly Developed Zn-Cu-Mn/Mg Alloys for Biodegradable Implant Application. ACS Biomater Sci Eng 2024; 10:6167-6190. [PMID: 39230934 DOI: 10.1021/acsbiomaterials.4c00082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2024]
Abstract
Scaffolds play a crucial role in bone tissue engineering to support the defect area through bone regeneration and defect reconstruction. Promising tissue regeneration without negative repercussions and avoidance of the lifelong presence inside the body make bioresorbable metals prosper in the field of regenerative medicine. Recently, Zn and its alloys have emerged as promising biodegradable materials for their moderate degradation rate and satisfactory biocompatibility. Nevertheless, it is very challenging for cells to adhere and grow over the Zn surface alone, which influences the tissue-implant integration. In this study, an attempt has been made to systematically investigate the bioactivity responses in terms of in vitro hemocompatibility, cytotoxicity, antibacterial activity, and in vivo biocompatibility of newly developed Zn-2Cu-0.5Mn/Mg alloy scaffolds with different surface roughness. The rough surface of Zn-2Cu-0.5Mg shows the highest degradation rate of 0.16 mm/yr. The rough surface exhibits a prominent role in the adsorption of protein, further enhancing cell adhesion. Concentration-dependent alloy extract shows the highest cell proliferation for 12.5% of the extract with a maximum cell viability of 101% in Zn-2Cu-0.5Mn and 108% in Zn-2Cu-0.5Mg after 3 d. Acceptable hemolysis percentages (less than 5%) with promising anticoagulation properties are observed for all of the conditions. Enhanced antibacterial (Staphylococcus aureus and Escherichia coli) activity due to a significant effect of ions illustrates the maximum killing effect on the bacterial colony for the rough Zn-2Cu-0.5Mg alloy. In addition, it is observed that for rough Zn-2Cu-0.5Mn/Mg alloys, the inflammatory response is minimal after subcutaneous implantation, and neo-bone tissue forms in the defect areas of the rat femur with satisfactory biosafety response. The osseointegration property of the Zn-2Cu-0.5Mg alloy is comparable to that of the Zn-2Cu-0.5Mn alloy. Therefore, the rough surface of the Zn-2Cu-0.5Mg alloy has the potential to enhance biocompatibility and promote better osseointegration activity with host tissues for various biomedical applications.
Collapse
Affiliation(s)
- Debajyoti Palai
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Trina Roy
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amiyangshu De
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sayan Mukherjee
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sharba Bandyopadhyay
- Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Karabi Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
5
|
Kumar A, Choudhari A, Gupta AK, Kumar A. Rare-Earth based magnesium alloys as a potential biomaterial for the future. JOURNAL OF MAGNESIUM AND ALLOYS 2024; 12:3841-3897. [DOI: 10.1016/j.jma.2024.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
6
|
Tong X, Miao D, Zhou R, Shen X, Luo P, Ma J, Li Y, Lin J, Wen C, Sun X. Mechanical properties, corrosion behavior, and in vitro and in vivo biocompatibility of hot-extruded Zn-5RE (RE = Y, Ho, and Er) alloys for biodegradable bone-fixation applications. Acta Biomater 2024; 185:55-72. [PMID: 38997078 DOI: 10.1016/j.actbio.2024.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 06/27/2024] [Accepted: 07/05/2024] [Indexed: 07/14/2024]
Abstract
Biodegradable Zn alloys have significant application potential for hard-tissue implantation devices owing to their suitable degradation behavior and favorable biocompatibility. Nonetheless, pure Zn and its alloys in the as-cast state are mechanically instable and low in strength, which restricts their clinical applicability. Here, we report the exceptional mechanical, corrosion, and biocompatibility properties of hot-extruded Zn-5RE (wt.%, RE = rare earth of Y; or Ho; or Er) alloys intended for use in biodegradable bone substitutes. The microstructural characteristics, mechanical behavior, corrosion resistance, cytocompatibility, osteogenic differentiation, and capacity of osteogenesis in vivo of the Zn-5RE alloys are comparatively investigated. The Zn-5Y alloy demonstrates the best tensile properties, encompassing a 138 MPa tensile yield strength, a 302 MPa ultimate tensile strength, and 63% elongation, while the Zn-5Ho alloy shows the highest compression yield strength of 260 MPa and Vickers hardness of 104 HV. The Zn-5Er alloy shows a 126 MPa tensile yield strength, a 279 MPa ultimate tensile strength, 52% elongation, a 196 MPa compression yield strength, and a 101 HV Vickers microhardness. Further, the Zn-5Er alloy has a 130 µm per year corrosion rate in electrochemical tests and a 26 µm per year degradation rate in immersion tests, which is the lowest among the tested alloys. It also has the best in vitro osteogenic differentiation ability and capacity for osteogenesis and osteointegration in vivo after implantation in rat femurs among the Zn-5RE alloys, indicating promising potential in load-bearing biodegradable internal bone-fixation applications. STATEMENT OF SIGNIFICANCE: This work reports the exceptional mechanical, corrosion, and biocompatibility properties of hot-extruded (HE) Zn-5 wt.%-rare earth (Zn-5RE) alloys using single yttrium (Y), holmium (Ho), and erbium (Er) alloying for biodegradable bone-implant applications. Our findings demonstrate that the HE Zn-5Er alloy showed σuts of 279 MPa, tensile yield strength of 126 MPa, elongation of 51.6%, compression yield strength of 196 MPa, and microhardness of 101.2 HV. Further, HE Zn-5Er showed the lowest electrochemical corrosion rate of 130 µm/y and lowest degradation rate of 26 µm/y, and the highest in vitro osteogenic differentiation ability, in vivo osteogenesis, and osteointegration ability after implantation in rat femurs among the Zn-5RE alloys, indicating promising potential in load-bearing biodegradable internal bone-fixation applications.
Collapse
Affiliation(s)
- Xian Tong
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Daoyi Miao
- Department of Orthopaedics, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Wenzhou 325016, China
| | - Runqi Zhou
- Chongqing Key Laboratory of Oral Disease and Biomedical Sciences and Chongqing Municipal Key Laboratory of Oral Biomedical Engineering, Higher Education and Stomatological Hospital, Chongqing Medical University, Chongqing 401174, China
| | - Xinkun Shen
- Department of Orthopaedics, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Wenzhou 325016, China
| | - Peng Luo
- Department of Orthopaedics, The Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000, China.
| | - Jianfeng Ma
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China
| | - Yuncang Li
- Centre for Additive Manufacturing, School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| | - Jixing Lin
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325000, China.
| | - Cuie Wen
- Centre for Additive Manufacturing, School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia.
| | - Xuecheng Sun
- Department of Gastroenterology, The First Affiliated Hospital of Wenzhou Medical University, Wenzhou 325000, China.
| |
Collapse
|
7
|
Cesarz-Andraczke K, Staszuk M, Tunçay T, Woźniak A, Smok W, Tunçay B. Influence of casein on the degradation process of polylactide-casein coatings for resorbable alloys. Sci Rep 2024; 14:18946. [PMID: 39147799 PMCID: PMC11327277 DOI: 10.1038/s41598-024-69956-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Accepted: 08/12/2024] [Indexed: 08/17/2024] Open
Abstract
This study used the dip-coating method to develop a new biocompatible coating composed of polylactide (PLA) and casein for ZnMg1.2 wt% alloy implants. It evaluated its impact on the alloy's degradation in a simulated body fluid. After 168 h of immersion in Ringer's solution, surface morphology analysis showed that the PLA-casein coatings demonstrated uniform degradation, with the corrosion current density measured at 48 µA/cm2. Contact angle measurements indicated that the average contact angles for the PLA-casein-coated samples were below 80°, signifying a hydrophilic nature that promotes cell adhesion. Fourier-transform infrared spectroscopy (FTIR) revealed no presence of lactic acid on PLA-casein coatings after immersion, in contrast to pure PLA coatings. Pull-off adhesion tests showed tensile strength values of 7.6 MPa for pure PLA coatings and 5 MPa for PLA-casein coatings. Electrochemical tests further supported the favorable corrosion resistance of the PLA-casein coatings, highlighting their potential to reduce tissue inflammation and improve the biocompatibility of ZnMg1.2 wt% alloy implants.
Collapse
Affiliation(s)
- Katarzyna Cesarz-Andraczke
- Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, Gliwice, Poland.
| | - Marcin Staszuk
- Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, Gliwice, Poland
| | - Tansel Tunçay
- Manufacturing Engineering Department, Technology Faculty, Karabuk University, Karabuk, Turkey
| | - Anna Woźniak
- Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, Gliwice, Poland
| | - Weronika Smok
- Department of Engineering Materials and Biomaterials, Faculty of Mechanical Engineering, Silesian University of Technology, Gliwice, Poland
| | - Badegül Tunçay
- Mechanical Engineering Department, Engineering Faculty, Karabuk University, Karabuk, Turkey
| |
Collapse
|
8
|
Palai D, De A, Prasad PS, Roy T, Mukherjee S, Dhara S, Das S, Das K. Feasibility Insights of the Green-Assisted Calcium-Phosphate Coating on Biodegradable Zinc Alloys for Biomedical Application: In Vitro and In Vivo Studies. ACS APPLIED MATERIALS & INTERFACES 2024. [PMID: 38699930 DOI: 10.1021/acsami.4c02540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2024]
Abstract
In the field of bone tissue engineering, recently developed Zn alloy scaffolds are considered potential candidates for biodegradable implants for bone regeneration and defect reconstruction. However, the clinical success of these alloys is limited due to their insufficient surface bioactivities. Further, the higher concentration of Zn2+ produced during degradation promotes antibacterial activity, but deteriorates osteogenic properties. This study fabricated an Azadirachta indica (neem)-assisted brushite-hydroxyapatite (HAp) coating on the recently developed Zn-2Cu-0.5Mg alloy to tackle the above dilemma. The microstructure, degradation behavior, antibacterial activity, and hemocompatibility, along with in vitro and in vivo cytocompatibility of the coated alloys, are systematically investigated. Microstructural analysis reveals flower-like morphology with uniformly grown flakes for neem-assisted deposition. The neem-assisted deposition significantly improves the adhesion strength from 12.7 to 18.8 MPa, enhancing the mechanical integrity. The potentiodynamic polarization study shows that the neem-assisted deposition decreases the degradation rate, with the lowest degradation rate of 0.027 mm/yr for the ZHN2 sample. In addition, the biomineralization process shows the apatite formation on the deposited coating after 21 days of immersion. In vitro cytotoxicity assay exhibits the maximum cell viability of 117% for neem-assisted coated alloy in 30% extract after 5d and the improved cytocompatibility which is due to the controlled release of Zn2+ ions. Meanwhile, neem-assisted coated alloy increases the ZOI by 32 and 24% for Gram-positive and Gram-negative bacteria, respectively. Acceptable hemolysis (<5%) and anticoagulation parameters demonstrate a promising hemocompatibility of the coated alloy. In vivo implantation illustrates a slight inflammatory response and vascularization after 2 weeks of subcutaneous implantation, and neo-bone formation in the defect areas of the rat femur. Micro-CT and histology studies demonstrate better osseointegration with satisfactory biosafety response for the neem-assisted coated alloy as compared to that without neem-assisted deposition. Hence, this neem-assisted brushite-Hap coating strategy elucidates a new perspective on the surface modification of biodegradable implants for the treatment of bone defects.
Collapse
Affiliation(s)
- Debajyoti Palai
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Amiyangshu De
- Advanced Technology Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - P Siva Prasad
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Trina Roy
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Sayan Mukherjee
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Karabi Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
9
|
Tong X, Dong Y, Han Y, Zhou R, Zhu L, Zhang D, Dai Y, Shen X, Li Y, Wen C, Lin J. A biodegradable Zn-5Gd alloy with biomechanical compatibility, cytocompatibility, antibacterial ability, and in vitro and in vivo osteogenesis for orthopedic applications. Acta Biomater 2024; 177:538-559. [PMID: 38253302 DOI: 10.1016/j.actbio.2024.01.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Revised: 12/21/2023] [Accepted: 01/15/2024] [Indexed: 01/24/2024]
Abstract
Zinc (Zn) and some of its alloys are recognized as promising biodegradable implant materials due to their acceptable biocompatibility, facile processability, and moderate degradation rate. Nevertheless, the limited mechanical properties and stability of as-cast Zn alloys hinder their clinical application. In this work, hot-rolled (HR) and hot-extruded (HE) Zn-5 wt.% gadolinium (Zn-5Gd) samples were prepared by casting and respectively combining with hot rolling and hot extrusion for bone-implant applications. Their microstructure evolution, mechanical properties, corrosion behavior, cytotoxicity, antibacterial ability, and in vitro and in vivo osteogenesis were systematically evaluated. The HR and HE Zn-5Gd exhibited significantly improved mechanical properties compared with those of their pure Zn counterparts and the HR Zn-5Gd showed a unique combination of tensile properties with an ultimate tensile strength of ∼311.6 MPa, yield strength of ∼236.5 MPa, and elongation of ∼40.6%, all of which are greater than the mechanical properties required for bone-implant materials. The HR and HE Zn-5Gd showed higher corrosion resistance than their pure Zn counterpart in Hanks' solution and the HE Zn-5Gd had the lowest corrosion rate of 155 µm/y measured by electrochemical corrosion and degradation rate of 26.9 µm/y measured by immersion testing. The HR and HE Zn-5Gd showed high cytocompatibility toward MC3T3-E1 and MG-63 cells, high antibacterial effects against S. aureus, and better in vitro osteogenic activity than their pure Zn counterparts. Furthermore, the HE Zn-5Gd exhibited better in vivo biocompatibility, osteogenesis, and osteointegration ability than pure Zn and pure Ti. STATEMENT OF SIGNIFICANCE: This work reports the mechanical properties, corrosion behaviors, cytocompatibility, antibacterial ability, in vitro and in vivo osteogenesis of biodegradable Zn-Gd alloy for bone-implant applications. Our findings demonstrate that the hot-rolled (HR) Zn-5Gd showed a unique combination of tensile properties with an ultimate tensile strength of ∼311.6 MPa, yield strength of ∼236.5 MPa, and elongation of ∼40.6%. The HR and HE Zn-5Gd showed higher corrosion resistance than their pure Zn counterpart in Hanks' solution. The HR and HE Zn-5Gd showed high cytocompatibility toward MC3T3-E1 and MG-63 cells, good antibacterial effects against S. aureus, and better in vitro osteogenic activity. Furthermore, the HE Zn-5Gd exhibited better in vivo biocompatibility, osteogenesis, and osteointegration ability than pure Zn and pure Ti.
Collapse
Affiliation(s)
- Xian Tong
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Yilong Dong
- Department of Orthopaedics, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Wenzhou 325016, China
| | - Yue Han
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Runqi Zhou
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
| | - Li Zhu
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Dechuang Zhang
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Yilong Dai
- School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Xinkun Shen
- Department of Orthopaedics, The Third Affiliated Hospital of Wenzhou Medical University (Ruian People's Hospital), Wenzhou 325016, China
| | - Yuncang Li
- School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia.
| | - Jixing Lin
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
| |
Collapse
|
10
|
Palai D, Siva Prasad P, Satpathy B, Das S, Das K. Development of Zn-2Cu- xMn/Mg Alloys for Orthopedic Applications: Mechanical Performance to In Vitro Degradation under Different Physiological Environments. ACS Biomater Sci Eng 2023; 9:6058-6083. [PMID: 37774322 DOI: 10.1021/acsbiomaterials.3c00641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2023]
Abstract
Zinc (Zn) and its alloys are considered futuristic biodegradable materials for their acceptable mechanical properties, suitable corrosion rate, and good biocompatibility. In this study, we report newly developed biodegradable Zn-2Cu-xMn/Mg (x = 0, 0.1, and 0.5) alloys, aiming to achieve good mechanical strength with excellent elongation, desirable wear resistance, and suitable corrosion rate. The effect of Mn/Mg addition on the structural, mechanical, wear, and degradation behaviors of the Zn-2Cu-xMn/Mg alloys was thoroughly investigated. Degradation and tribological behaviors of the alloys were explored in the presence of simulated body fluid (SBF), Dulbecco's modified Eagle medium (DMEM), and DMEM with a 10% fetal bovine serum (FBS) solution. Alloy elements and hot rolling improve their mechanical properties significantly due to precipitation hardening, grain refinement, and solid solution strengthening owing to the formation of MnZn13 and Mg2Zn11 phases. Among all the alloys, the Zn-2Cu-0.5Mn alloy achieved the highest ultimate tensile strength (UTS) of ∼405 MPa and yield strength (YS) of ∼293 MPa with an excellent elongation of ∼51%. The corrosion behavior of the alloys as determined by a potentiodynamic polarization study under different solutions follows the sequence Zn-2Cu < Zn-2Cu-0.5Mn < Zn-2Cu-0.1Mn < Zn-2Cu-0.1Mg < Zn-2Cu-0.5Mg. The corrosion rate by immersion testing for 30 and 90 days also follows the same sequence. The corrosion rate in different solutions follows the order SBF > DMEM + 10%FBS > DMEM. The addition of Mn/Mg also improves the wear resistance and slows the wear rate under wet conditions. The bending test results also indicate the highest bending strength of ∼375 MPa for the Zn-2Cu-0.5Mn alloy, among all the alloys. The bending and tensile strengths deteriorate continuously after the immersion for 30 and 90 days in the solution of SBF, DMEM, and DMEM + 10%FBS. Therefore, the Zn-2Cu-xMn/Mg (x = 0.1 and 0.5) alloys can be considered potential biodegradable implant materials.
Collapse
Affiliation(s)
- Debajyoti Palai
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - P Siva Prasad
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Bangmaya Satpathy
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Siddhartha Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| | - Karabi Das
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
| |
Collapse
|
11
|
Tong X, Han Y, Zhou R, Zeng J, Wang C, Yuan Y, Zhu L, Huang S, Ma J, Li Y, Wen C, Lin J. Mechanical properties, corrosion and degradation behaviors, and in vitro cytocompatibility of a biodegradable Zn-5La alloy for bone-implant applications. Acta Biomater 2023; 169:641-660. [PMID: 37541605 DOI: 10.1016/j.actbio.2023.07.061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 07/04/2023] [Accepted: 07/28/2023] [Indexed: 08/06/2023]
Abstract
Zinc (Zn) and its alloys are used in bone-fixation devices as biodegradable bone-implant materials due to their good biosafety, biological function, biodegradability, and formability. Unfortunately, the clinical application of pure Zn is hindered by its insufficient mechanical properties and slow degradation rate. In this study, a Zn-5 wt.% lanthanum (Zn-5La) alloy with enhanced mechanical properties, suitable degradation rate, and cytocompatibility was developed through La alloying and hot extrusion. The hot-extruded (HE) Zn-5La alloy showed ultimate tensile strength of 286.3 MPa, tensile yield strength of 139.7 MPa, elongation of 35.7%, compressive yield strength of 262.7 MPa, and microhardness of 109.7 HV. The corrosion resistance of the HE Zn-5La in Hanks' and Dulbecco's modified Eagle medium (DMEM) solutions gradually increased with prolonged immersion time. Further, the HE Zn-5La exhibited an electrochemical corrosion rate of 36.7 μm/y in Hanks' solution and 11.4 μm/y in DMEM solution, and a degradation rate of 49.5 μm/y in Hanks' solution and 30.3 μm/y in DMEM solution, after 30 d of immersion. The corrosion resistance of both HE Zn and Zn-5La in DMEM solution was higher than in Hanks' solution. The 25% concentration extract of the HE Zn-5La showed a cell viability of 106.5%, indicating no cytotoxicity toward MG-63 cells. We recommend the HE Zn-5La alloy as a promising candidate material for biodegradable bone-implant applications. STATEMENT OF SIGNIFICANCE: This work reports the mechanical properties, corrosion and degradation behaviors, in vitro cytocompatibility and antibacterial ability of biodegradable Zn-5La alloy for bone-implant applications. Our findings demonstrate that the hot-extruded (HE) Zn-5La alloy showed an ultimate tensile strength of 286.3 MPa, a yield strength of 139.7 MPa, an elongation of 35.7%, compressive yield strength of 262.7 MPa, and microhardness of 109.7 HV. HE Zn-5La exhibited appropriate degradation rates in Hanks' and DMEM solutions. Furthermore, the HE Zn-5La alloy showed good cytocompatibility toward MG-63 and MC3T3-E1 cells and greater antibacterial ability against S. aureus.
Collapse
Affiliation(s)
- Xian Tong
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China.
| | - Yue Han
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Runqi Zhou
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Jun Zeng
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Cheng Wang
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Yifan Yuan
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Li Zhu
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Shengbin Huang
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Jianfeng Ma
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Yuncang Li
- School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia.
| | - Jixing Lin
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
| |
Collapse
|
12
|
Singh Raman RK, Wen C, Löffler JF. Human Body-Fluid-Assisted Fracture of Zinc Alloys as Biodegradable Temporary Implants: Challenges, Research Needs and Way Forward. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4984. [PMID: 37512259 PMCID: PMC10383560 DOI: 10.3390/ma16144984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 07/02/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023]
Abstract
Alloys of magnesium, zinc or iron that do not contain toxic elements are attractive as construction material for biodegradable implants, i.e., the type of implants that harmlessly dissolve away within the human body after they have completed their intended task. The synergistic influence of mechanical stress and corrosive human body fluid can cause sudden and catastrophic fracture of bioimplants due to phenomena such as stress corrosion cracking (SCC) and corrosion fatigue (CF). To date, SCC and CF of implants based on Zn have scarcely been investigated. This article is an overview of the challenges, research needs and way forward in understanding human body-fluid-assisted fractures (i.e., SCC and CF) of Zn alloys in human body fluid.
Collapse
Affiliation(s)
- R K Singh Raman
- Department of Mechanical & Aerospace Engineering, Monash University, Clayton, VIC 3800, Australia
- Department of Chemical & Biological Engineering, Monash University, Clayton, VIC 3800, Australia
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne VIC 3001, Australia
| | - Jörg F Löffler
- Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland
| |
Collapse
|
13
|
Heiss A, Thatikonda VS, Richter A, Schmitt LY, Park D, Klotz UE. Development, Processing and Aging of Novel Zn-Ag-Cu Based Biodegradable Alloys. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3198. [PMID: 37110036 PMCID: PMC10141850 DOI: 10.3390/ma16083198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 04/08/2023] [Accepted: 04/14/2023] [Indexed: 06/19/2023]
Abstract
The use of biodegradable materials for implants is a promising strategy to overcome known long-term clinical complications related to permanent implants. Ideally, biodegradable implants support the damaged tissue for a certain period and then degrade, while the physiological function of the surrounding tissue is restored. Although Mg-based alloys nearly ideally lend themselves to biodegradable implants, a few critical shortcomings promoted the development of alternative alloy systems. Due to their reasonably good biocompatibility, moderate corrosion rate without hydrogen evolution and adequate mechanical properties, increasing attention has been paid to Zn alloys. In this work, precipitation-hardening alloys in the system Zn-Ag-Cu were developed relying on thermodynamic calculations. After casting the alloys, their microstructures were refined by thermomechanical treatment. The processing was tracked and directed, respectively, by routine investigations of the microstructure, associated with hardness assessments. Although microstructure refinement increased the hardness, the material proved to be susceptible to aging as the homologous temperature of zinc is at 0.43 Tm. Besides mechanical performance and corrosion rate, long-term mechanical stability is another crucial factor that must be taken into consideration to ensure the safety of the implant and thus requires a profound understanding of the aging process.
Collapse
Affiliation(s)
- Alexander Heiss
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Venkat Sai Thatikonda
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
- Department of Precision-Optics-Materials-Environment, University of Applied Sciences, 07745 Jena, Germany
| | - Andreas Richter
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Lisa-Yvonn Schmitt
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| | - Daesung Park
- Physikalisch-Technische Bundesanstalt (PTB), 38116 Braunschweig, Germany
- Laboratory of Emerging Nanometrology (LENA), 38106 Braunschweig, Germany
| | - Ulrich E. Klotz
- Department of Physical Metallurgy, Research Institute for Precious Metals and Metals Chemistry (fem), Katharinenstrasse 17, 73525 Schwaebisch Gmuend, Germany
| |
Collapse
|
14
|
Liu Q, Li A, Liu S, Fu Q, Xu Y, Dai J, Li P, Xu S. Cytotoxicity of Biodegradable Zinc and Its Alloys: A Systematic Review. J Funct Biomater 2023; 14:206. [PMID: 37103296 PMCID: PMC10144193 DOI: 10.3390/jfb14040206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/18/2023] [Accepted: 03/27/2023] [Indexed: 04/28/2023] Open
Abstract
Zinc-based biodegradable metals (BMs) have been developed for biomedical implant materials. However, the cytotoxicity of Zn and its alloys has caused controversy. This work aims to investigate whether Zn and its alloys possess cytotoxic effects and the corresponding influence factors. According to the guidelines of the PRISMA statement, an electronic combined hand search was conducted to retrieve articles published in PubMed, Web of Science, and Scopus (2013.1-2023.2) following the PICOS strategy. Eighty-six eligible articles were included. The quality of the included toxicity studies was assessed utilizing the ToxRTool. Among the included articles, extract tests were performed in 83 studies, and direct contact tests were conducted in 18 studies. According to the results of this review, the cytotoxicity of Zn-based BMs is mainly determined by three factors, namely, Zn-based materials, tested cells, and test system. Notably, Zn and its alloys did not exhibit cytotoxic effects under certain test conditions, but significant heterogeneity existed in the implementation of the cytotoxicity evaluation. Furthermore, there is currently a relatively lower quality of current cytotoxicity evaluation in Zn-based BMs owing to the adoption of nonuniform standards. Establishing a standardized in vitro toxicity assessment system for Zn-based BMs is required for future investigations.
Collapse
Affiliation(s)
- Qian Liu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - An Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shizhen Liu
- The School of Computing Science, University of Glasgow, Glasgow G12 8RZ, UK
| | - Qingyun Fu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Yichen Xu
- State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, Department of Oral Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Jingtao Dai
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, Guangzhou 510280, China
| |
Collapse
|
15
|
Su Y, Fu J, Zhou J, Georgas E, Du S, Qin YX, Wang Y, Zheng Y, Zhu D. Blending with transition metals improves bioresorbable zinc as better medical implants. Bioact Mater 2023; 20:243-258. [PMID: 35702610 PMCID: PMC9166432 DOI: 10.1016/j.bioactmat.2022.05.033] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 05/27/2022] [Accepted: 05/27/2022] [Indexed: 12/04/2022] Open
Abstract
Zinc (Zn) is a new class of bioresorbable metal that has potential for cardiovascular stent material, orthopedic implants, wound closure devices, etc. However, pure Zn is not ideal for these applications due to its low mechanical strength and localized degradation behavior. Alloying is the most common/effective way to overcome this limitation. Still, the choice of alloying element is crucial to ensure the resulting alloy possesses sufficient mechanical strength, suitable degradation rate, and acceptable biocompatibility. Hereby, we proposed to blend selective transition metals (i.e., vanadium-V, chromium-Cr, and zirconium-Zr) to improve Zn's properties. These selected transition metals have similar properties to Zn and thus are beneficial for the metallurgy process and mechanical property. Furthermore, the biosafety of these elements is of less concern as they all have been used as regulatory approved medical implants or a component of an implant such as Ti6Al4V, CoCr, or Zr-based dental implants. Our study showed the first evidence that blending with transition metals V, Cr, or Zr can improve Zn's properties as bioresorbable medical implants. In addition, three in vivo implantation models were explored in rats: subcutaneous, aorta, and femoral implantations, to target the potential clinical applications of bioresorbable Zn implants. Tensile strength and elongation of Zn alloys can reach over 220 MPa and 30%, respectively. Three in vivo implantation models to investigate and compare biodegradations behavior at different locations of the body. Zn–Zr and Zn–V alloys can induce pro-regenerative inflammation responses in aortas. All Zn alloys can promote osteointegration in femur.
Collapse
|
16
|
Diaa AA, El-Mahallawy N, Shoeib M, Lallemand N, Mouillard F, Masson P, Carradò A. Effect of Mg Addition and PMMA Coating on the Biodegradation Behaviour of Extruded Zn Material. MATERIALS (BASEL, SWITZERLAND) 2023; 16:707. [PMID: 36676444 PMCID: PMC9863199 DOI: 10.3390/ma16020707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 12/29/2022] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
Although zinc (Zn) is one of the elements with the greatest potential for biodegradable uses, pure Zn does not have the ideal mechanical or degrading properties for orthopaedic applications. The current research aims at studying the microstructure and corrosion behaviour of pure Zn (used as a reference material) and Zn alloyed with 1.89 wt.% magnesium (Mg), both in their extruded states as well as after being coated with polymethyl methacrylate (PMMA). The grafting-from approach was used to create a PMMA covering. The "grafting-from" method entails three steps: the alkali activation of the alloys, their functionalization with an initiator of polymerization through a phosphonate-attaching group, and the surface-initiated atom transfer radical polymerisation (SI-ATRP) to grow PMMA chains. Electrochemical and immersion corrosion tests were carried out in a simulated body fluid (SBF), and both confirmed the enhanced corrosion behaviour obtained after coating. The electrochemical test revealed a decrease in the degradation rate of the alloy from 0.37 ± 0.14 mm/y to 0.22 ± 0.01 mm/y. The immersion test showed the ability of complete protection for 240 h. After 720 h of immersion, the coated alloy displays minute crevice corrosion with very trivial pitting compared to the severe localized (galvanic and pitting) corrosion type that was detected in the bare alloy.
Collapse
Affiliation(s)
- Alia A. Diaa
- Design and Production Engineering Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
- Department of Design and Production Engineering, Faculty of Engineering and Materials Science, German University in Cairo, Cairo 11835, Egypt
| | - Nahed El-Mahallawy
- Design and Production Engineering Department, Faculty of Engineering, Ain Shams University, Cairo 11517, Egypt
- Department of Design and Production Engineering, Faculty of Engineering and Materials Science, German University in Cairo, Cairo 11835, Egypt
| | - Madiha Shoeib
- Central Metallurgical Research and Development Institute, El Tebbin, Cairo 11722, Egypt
| | - Nicolas Lallemand
- Institut de Physique et Chimie des Matériaux de Strasbourg, IPCMS, UMR 7504 CNRS, Université de Strasbourg, 67000 Strasbourg, France
| | - Flavien Mouillard
- Institut de Physique et Chimie des Matériaux de Strasbourg, IPCMS, UMR 7504 CNRS, Université de Strasbourg, 67000 Strasbourg, France
| | - Patrick Masson
- Institut de Physique et Chimie des Matériaux de Strasbourg, IPCMS, UMR 7504 CNRS, Université de Strasbourg, 67000 Strasbourg, France
| | - Adele Carradò
- Institut de Physique et Chimie des Matériaux de Strasbourg, IPCMS, UMR 7504 CNRS, Université de Strasbourg, 67000 Strasbourg, France
| |
Collapse
|
17
|
Du S, Shen Y, Zheng Y, Cheng Y, Xu X, Chen D, Xia D. Systematic in vitro and in vivo study on biodegradable binary Zn-0.2 at% Rare Earth alloys (Zn-RE: Sc, Y, La-Nd, Sm-Lu). Bioact Mater 2023; 24:507-523. [PMID: 36685807 PMCID: PMC9841038 DOI: 10.1016/j.bioactmat.2023.01.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 01/03/2023] [Accepted: 01/03/2023] [Indexed: 01/12/2023] Open
Abstract
Biomedical implants and devices for tissue engineering in clinics, mainly made of polymers and stiff metallic materials, require possibly secondary surgery or life-long medicine. Biodegradable metals for biomedical implants and devices exhibit huge potential to improve the prognosis of patients. In this work, we developed a new type of biodegradable binary zinc (Zn) alloys with 16 rare earth elements (REEs) including Sc, Y, La to Nd, and Sm to Lu, respectively. The effects of REEs on the alloy microstructure, mechanical properties, corrosion behavior and in vitro and in vivo biocompatibility of Zn were systematically investigated using pure Zn as control. All Zn-RE alloys generally exhibited improved mechanical properties, and biocompatibilities compared to pure Zn, especially the tensile strength and ductility of Zn-RE alloys were dramatically enhanced. Among the Zn-RE alloys, different REEs presented enhancement effects at varied extent. Y, Ho and Lu were the three elements displaying greatest improvements in majority of alloys properties, while Eu, Gd and Dy exhibited least improvement. Furthermore, the Zn-RE alloys were comparable with other Zn alloys and also exhibited superior properties to Mg-RE alloys. The in vivo experiment using Zn-La, Zn-Ce, and Zn-Nd alloys as tibia bone implants in rabbit demonstrated the excellent tissue biocompatibility and much more obvious osseointegration than the pure Zn control group. This work presented the significant potential of the developed Zn-RE binary alloys as novel degradable metal for biomedical implants and devices.
Collapse
Affiliation(s)
- Shaokang Du
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China
| | - Yunong Shen
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Yufeng Zheng
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Yan Cheng
- Academy for Advanced Interdisciplinary Studies, Peking University, Beijing, 100871, China
| | - Xiaoxue Xu
- School of Biomedical Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney, NSW, 2007, Australia,Corresponding author.
| | - Dafu Chen
- Laboratory of Bone Tissue Engineering, Beijing Laboratory of Biomedical Materials, Beijing Research Institute of Traumatology and Orthopaedics, Beijing Jishuitan Hospital, Beijing, 100035, China,Corresponding author.
| | - Dandan Xia
- Department of Dental Materials, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing 100081, China,Corresponding author.
| |
Collapse
|
18
|
Tong X, Han Y, Zhou R, Jiang W, Zhu L, Li Y, Huang S, Ma J, Wen C, Lin J. Biodegradable Zn-Dy binary alloys with high strength, ductility, cytocompatibility, and antibacterial ability for bone-implant applications. Acta Biomater 2023; 155:684-702. [PMID: 36328128 DOI: 10.1016/j.actbio.2022.10.053] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Revised: 09/16/2022] [Accepted: 10/25/2022] [Indexed: 11/05/2022]
Abstract
The unique combination of biodegradability, biocompatibility, and functionality of zinc (Zn)-based alloys makes them highly desirable for a wide range of medical applications. However, a long-standing problem associated with this family of biodegradable alloys in the as-cast state is their limited mechanical strength and slow degradation rate. Here we report the development of Zn-xDy (x = 1, 3, and 5 wt.%) alloys with high strength, ductility, cytocompatibility, antibacterial ability, and appropriate degradation rate for biodegradable bone-implant applications. Our results indicate that the mechanical properties of Zn-xDy alloys were effectively improved with increasing Dy addition and hot-rolling due to the second-phase strengthening. The hot-rolled (HR) Zn-3Dy alloy showed the best combined mechanical performance with an ultimate tensile strength of 270.5 MPa, a yield strength of 214.8 MPa, an elongation of 55.1%, and Brinell hardness of 75.9 HB. The corrosion and degradation rates of HR Zn-xDy alloys in Hanks' solution gradually increased with increasing Dy addition due to the intensification of galvanic corrosion. The HR Zn-3Dy alloy showed high antibacterial ability against S. aureus and cytocompatibility toward MC3T3-E1 cells among all the HR alloys. Overall, the HR Zn-3Dy alloy can be considered a promising biodegradable material for bone implants. STATEMENT OF SIGNIFICANCE: This work reports on Zn-xDy (x = 1, 3, and 5%) alloys fabricated by Dy alloying followed by hot-rolling for biodegradable bone-implant applications. Our findings demonstrate that the hot-rolled (HR) Zn-3Dy alloy showed the best combined mechanical performance with an ultimate tensile strength of 270.5 MPa, a yield strength of 214.8 MPa, an elongation of 55.1%, and Brinell hardness of 75.9 HB. The corrosion and degradation rates of HR Zn-xDy alloys in Hanks' solution gradually increased with increasing Dy addition due to the intensification of galvanic corrosion. Furthermore, the HR Zn-3Dy alloy showed greater antibacterial ability against S. aureus and the best cytocompatibility toward MC3T3-E1 cells among all the HR alloys.
Collapse
Affiliation(s)
- Xian Tong
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China; School of Materials Science and Engineering, Xiangtan University, Xiangtan 411105, China
| | - Yue Han
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Runqi Zhou
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Wanying Jiang
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Li Zhu
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China
| | - Yuncang Li
- School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia
| | - Shengbin Huang
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
| | - Jianfeng Ma
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
| | - Cuie Wen
- School of Engineering, RMIT University, Melbourne, Victoria 3001, Australia.
| | - Jixing Lin
- Institute of Stomatology, School and Hospital of Stomatology, Wenzhou Medical University, Wenzhou 325027, China.
| |
Collapse
|
19
|
Hussain M, Ullah S, Raza MR, Abbas N, Ali A. Recent Developments in Zn-Based Biodegradable Materials for Biomedical Applications. J Funct Biomater 2022; 14:1. [PMID: 36662048 PMCID: PMC9865652 DOI: 10.3390/jfb14010001] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 12/13/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022] Open
Abstract
Zn-based biodegradable alloys or composites have the potential to be developed to next-generation orthopedic implants as alternatives to conventional implants to avoid revision surgeries and to reduce biocompatibility issues. This review summarizes the current research status on Zn-based biodegradable materials. The biological function of Zn, design criteria for orthopedic implants, and corrosion behavior of biodegradable materials are briefly discussed. The performance of many novel zinc-based biodegradable materials is evaluated in terms of biodegradation, biocompatibility, and mechanical properties. Zn-based materials perform a significant role in bone metabolism and the growth of new cells and show medium degradation without the release of excessive hydrogen. The addition of alloying elements such as Mg, Zr, Mn, Ca, and Li into pure Zn enhances the mechanical properties of Zn alloys. Grain refinement by the application of post-processing techniques is effective for the development of many suitable Zn-based biodegradable materials.
Collapse
Affiliation(s)
- Muzamil Hussain
- Department of Mechanical Engineering, COMSATS University Islamabad, Sahiwal Campus, Punjab 57000, Pakistan
| | - Sami Ullah
- Department of Chemistry, College of Science, King Khalid University, Abha 61413, Saudi Arabia
| | - Muhammad Rafi Raza
- Department of Mechanical Engineering, COMSATS University Islamabad, Sahiwal Campus, Punjab 57000, Pakistan
| | - Naseem Abbas
- Department of Mechanical Engineering, Sejong University, Seoul 05006, Republic of Korea
| | - Ahsan Ali
- Department of Mechanical Engineering, Gachon University, Seongnam-si 13120, Republic of Korea
| |
Collapse
|
20
|
Fan M, Zhao F, Peng S, Dai Q, Liu Y, Yin S, Zhang Z. Biocompatibility of Zinc Matrix Biodegradable Composites Reinforced by Graphene Nanosheets. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15186481. [PMID: 36143793 PMCID: PMC9502503 DOI: 10.3390/ma15186481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 09/12/2022] [Accepted: 09/15/2022] [Indexed: 05/17/2023]
Abstract
As a new type of biodegradable implant material, zinc matrix composites have excellent potential in the application of biodegradable implants because of their better corrosion resistance than magnesium matrix materials. Our previous studies have shown that graphene nanosheet reinforced zinc matrix composites (Zn-GNS) prepared by spark plasma sintering (SPS) have good mechanical properties and suitable degradation rate. However, the biocompatibility of zinc matrix composites is still a problem of concern. The cytocompatibility and blood compatibility of pure zinc and Zn-GNS composites in vitro were studied. The results showed that Zn-GNS composites had acceptable toxicity to MG-63 human osteosarcoma cells. In addition, the hemolysis rate of pure zinc and its composites were less than 3%, which has no adverse effect on adhered platelets, and has good antithrombotic and antiadhesion platelets properties. In conclusion, the addition of GNS did not adversely affect the biocompatibility of Zn-GNS composites, which indicated that Zn-GNS composites are a promising candidate for bone implantation.
Collapse
Affiliation(s)
- Mei Fan
- College of Materials and Metallurgy, Guizhou University, Guiyang 550025, China
- Key Laboratory for Materials Structure and Strength of Guizhou Province, Guiyang 550025, China
| | - Fei Zhao
- College of Materials and Metallurgy, Guizhou University, Guiyang 550025, China
- Key Laboratory for Materials Structure and Strength of Guizhou Province, Guiyang 550025, China
- Correspondence: (F.Z.); (Z.Z.)
| | - Shanshan Peng
- Hospital of Guizhou University, Guiyang 550025, China
| | - Qianfei Dai
- College of Materials and Metallurgy, Guizhou University, Guiyang 550025, China
- Key Laboratory for Materials Structure and Strength of Guizhou Province, Guiyang 550025, China
| | - Yuan Liu
- College of Materials and Metallurgy, Guizhou University, Guiyang 550025, China
- Key Laboratory for Materials Structure and Strength of Guizhou Province, Guiyang 550025, China
| | - Sheng Yin
- College of Materials and Metallurgy, Guizhou University, Guiyang 550025, China
- Key Laboratory for Materials Structure and Strength of Guizhou Province, Guiyang 550025, China
| | - Zongkui Zhang
- Hospital of Guizhou University, Guiyang 550025, China
- Correspondence: (F.Z.); (Z.Z.)
| |
Collapse
|
21
|
Huang H, Li G, Jia Q, Bian D, Guan S, Kulyasova O, Valiev RZ, Rau JV, Zheng Y. Recent advances on the mechanical behavior of zinc based biodegradable metals focusing on the strain softening phenomenon. Acta Biomater 2022; 152:1-18. [PMID: 36028200 DOI: 10.1016/j.actbio.2022.08.041] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 08/12/2022] [Accepted: 08/17/2022] [Indexed: 01/09/2023]
Abstract
Zinc based biodegradable metals (BMs) show great potential to be used in various biomedical applications, owing to their superior biodegradability and biocompatibility. Some high-strength (ultimate tensile strength > 600 MPa) Zn based BMs have already been developed through alloying and plastic working, making their use in load-bearing environments becomes a reality. However, different from Mg and Fe based BMs, Zn based BMs exhibit significant "strain-softening" effect that leads to limited uniform deformation. Non-uniform deformation is detrimental to Zn based devices or implants, which will possibly lead to unexpected failure. People might be misled by the considerable fracture elongation of Zn based BMs. Thus, it is important to specify uniform elongation as a term of mechanical requirements for Zn based BMs. In this review, recent advances on the mechanical properties of Zn based BMs have been comprehensively summarized, especially focusing on the strain softening phenomenon. At first, the origin and evaluation criteria of strain softening were introduced. Secondly, the effects of alloying elements (including element type, single or multiple addition, and alloying content) and microstructural characteristics (grain size, constituent phase, phase distribution, etc.) on mechanical properties (especially for uniform elongation) of Zn based BMs were summarized. Finally, how to get a good balance between strength and uniform elongation was generally discussed based on the service environment. In addition, possible ways to minimize or eliminate the strain softening effect were also proposed, such as controlling of twins, solute clusters, and grain boundary characteristics. All these items above would be helpful to understand the mechanical instability of Zn based BMs, and to make the full usage of them in the future medical device design. STATEMENT OF SIGNIFICANCE: Biodegradable metals (BMs) is a hotspot in the field of metallic biomaterials. Fracture elongation is normally adopted to quantify the deformability of Mg and Fe based BMs owing to their negligible necking strain, yet the strain softening would occur in Zn based BMs, which is extremely detrimental to performance of their medical device. In this review paper, a better understanding the mechanical performance of Zn-based BMs with the term "uniform elongation" instead of "fracture elongation" was depicted, and possible ways to minimize or eliminate the strain softening effect were also proposed, such as twins, solute clusters, self-stable dislocation network, and grain boundary characteristics. It would be helpful to understand the mechanical instability of Zn based BMs and making full usage of it in the future medical device design.
Collapse
Affiliation(s)
- He Huang
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China
| | - Guannan Li
- School of Materials Science and Engineering, Peking University, Beijing, 100871, China
| | - Qinggong Jia
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China
| | - Dong Bian
- Medical Research Center, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China.
| | - Shaokang Guan
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China
| | - Olga Kulyasova
- Institute of Physics of Advanced Materials, Ufa State Aviation Technical University, 12 K. Marx St., Ufa, 450008, Russia
| | - R Z Valiev
- Institute of Physics of Advanced Materials, Ufa State Aviation Technical University, 12 K. Marx St., Ufa, 450008, Russia
| | - Julietta V Rau
- Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche (ISM-CNR), Via del Fosso del Cavaliere, 100-00133, Rome, Italy; Sechenov First Moscow State Medical University, Institute of Pharmacy, Department of Analytical, Physical and Colloid Chemistry, Trubetskaya 8, build. 2, 119991 Moscow, Russia
| | - Yufeng Zheng
- School of Materials Science and Engineering, Zhengzhou University, Zhengzhou, 450003, China; School of Materials Science and Engineering, Peking University, Beijing, 100871, China.
| |
Collapse
|
22
|
Tong X, Zhu L, Wu Y, Song Y, Wang K, Huang S, Li Y, Ma J, Wen C, Lin J. A biodegradable Fe/Zn-3Cu composite with requisite properties for orthopedic applications. Acta Biomater 2022; 146:506-521. [PMID: 35523413 DOI: 10.1016/j.actbio.2022.04.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 04/28/2022] [Accepted: 04/28/2022] [Indexed: 11/01/2022]
Abstract
Zinc (Zn)-based metals and alloys are emerging as promising biodegradable implant materials due to their inherent biodegradability and good biocompatibility. However, this class of materials exhibits low mechanical strength and a slow degradation rate, which hinders their clinical application. Here we report the development of a new biodegradable Fe/Zn-3Cu composite fabricated by infiltration casting of a Zn-3Cu alloy into an Fe foam followed by hot-rolling. Our results indicate that the hot-rolled (HR) Fe/Zn-3Cu composite exhibited an α-Zn matrix phase, a secondary CuZn5 phase, and an α-Fe phase. The HR Fe/Zn-3Cu composite exhibited an ultimate tensile strength of 269 MPa, a tensile yield strength of 210 MPa, and an elongation of 27%. The HR Fe/Zn-3Cu composite showed a degradation rate of 228 µm/year after immersion in Hanks' solution for 30 d The diluted extract of the HR Fe/Zn-3Cu composite exhibited a higher cell viability than that of the HR Zn-3Cu alloy in relation to MC3T3-E1 and MG-63 cells. Furthermore, the HR Fe/Zn-3Cu composite showed significantly better antibacterial ability than that of the HR Zn-3Cu alloy in relation to S. aureus. Overall, the HR Fe/Zn-3Cu composite can be anticipated to be a promising biodegradable implant material for bone-fixation applications. STATEMENT OF SIGNIFICANCE: This work reports a new biodegradable Fe/Zn-3Cu composite fabricated by infiltration casting and followed by hot-rolling for biodegradable bone-fixation application. Our findings demonstrated that the hot-rolled (HR) Fe/Zn-3Cu composite exhibited an ultimate tensile strength of 269.1 MPa, a tensile yield strength of 210.3 MPa, and an elongation of 26.7%. HR Fe/Zn-3Cu composite showed a degradation rate of 227.6 µm/a, higher than HR Zn-3Cu alloy after immersion in Hanks' solution for 30 d The diluted extracts of the HR Fe/Zn-3Cu composite exhibited a higher cell viability than HR Zn-3Cu alloy toward MC3T3-E1 cells. Furthermore, the HR Fe/Zn-3Cu composite showed significantly better antibacterial ability than the HR Zn-3Cu alloy toward S. aureus.
Collapse
|
23
|
A biodegradable in situ Zn-Mg 2Ge composite for bone-implant applications. Acta Biomater 2022; 146:478-494. [PMID: 35580830 DOI: 10.1016/j.actbio.2022.05.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Revised: 05/06/2022] [Accepted: 05/10/2022] [Indexed: 12/29/2022]
Abstract
Zinc (Zn)-based composites have received extensive attention as promising biodegradable materials due to their unique combination of moderate biodegradability, biocompatibility, and functionality. Nevertheless, the low mechanical strength of as-cast Zn-based composites impedes their practical clinical application. Here we reported the mechanical properties, corrosion behavior, wear properties, and cytotoxicity of in situ synthesized biodegradable Zn-xMg2Ge (x = 1, 3, and 5 wt.%) composites for bone-implant applications. The mechanical properties of Zn-xMg2Ge composites were effectively improved by alloying and hot-rolling due to particle reinforcement of the Mg2Ge intermetallic phase and dynamic recrystallization. The hot-rolled (HR) Zn-3Mg2Ge composite exhibited the best mechanical properties, including a yield strength of 162.3 MPa, an ultimate tensile strength of 264.3 MPa, an elongation of 10.9%, and a Brinell hardness of 83.9 HB. With an increase in Mg2Ge content, the corrosion and degradation rates of the HR Zn-xMg2Ge composites gradually increased, while their wear rate decreased and then increased in Hanks' solution. The diluted extract (12.5% concentration) of the HR Zn-3Mg2Ge composite showed the highest cell viability compared to the other HR composites and their as-cast pure Zn counterparts. Overall, the HR Zn-3Mg2Ge composite can be considered a promising biodegradable Zn-based composite for bone-implant applications. STATEMENT OF SIGNIFICANCE: This paper reports the mechanical properties, corrosion behavior, wear properties, and cytotoxicity of in situ synthesized biodegradable Zn-xMg2Ge (x = 1, 3, and 5 wt.%) composites for bone-implant applications. Our findings demonstrated that the mechanical properties of Zn-xMg2Ge composites were effectively improved by alloying and hot-rolling due to Mg2Ge particle reinforcement and dynamic recrystallization. The hot-rolled Zn-3Mg2Ge composite showed superior cytocompatibility, satisfying corrosion and degradation rates, and the best mechanical properties including a yield strength of 162.3 MPa, an ultimate tensile strength of 264.3 MPa, and an elongation of 10.9%.
Collapse
|
24
|
Tong X, Zhu L, Wang K, Shi Z, Huang S, Li Y, Ma J, Wen C, Lin J. Impact of gadolinium on mechanical properties, corrosion resistance, and biocompatibility of Zn-1Mg-xGd alloys for biodegradable bone-implant applications. Acta Biomater 2022; 142:361-373. [PMID: 35189378 DOI: 10.1016/j.actbio.2022.02.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 02/10/2022] [Accepted: 02/13/2022] [Indexed: 02/03/2023]
Abstract
Zinc (Zn) and its alloys are currently regarded as one of the promising families of biodegradable metals for implant applications owing to their suitable biodegradability and biofunctionality. However, the inadequate mechanical properties of as-cast (AC) pure Zn restricted the practical clinical bone-implant applications due to its coarse grain size and hexagon close-packed crystal structure. Here, the impact of gadolinium (Gd) on the mechanical properties, corrosion resistance, hemolysis percentage, anticoagulant activity, and cytotoxicity of AC and hot-rolled (HR) Zn-1Mg-xGd (x = 0.1, 0.2, and 0.3) (wt.%) alloys were investigated for biodegradable bone-implant applications. Tensile testing showed that the HR Zn-1Mg-0.3Gd alloy exhibited the highest tensile strength of 288.1 MPa, tensile yield strength of 250.9 MPa, and elongation of 13.2%. Electrochemical corrosion and immersion tests revealed that the corrosion rates of both AC and HR specimens increased with increasing Gd content in Hanks' solution, and the HR Zn-1Mg-xGd specimens exhibited higher corrosion rates compared to their AC counterparts. The HR Zn-1Mg-xGd specimens showed an increasing hemolysis percentages and decreasing activated partial thromboplastin time (APTT) values with increasing Gd addition. The alloy extracts of HR samples at ≤ 25% concentration exhibited no cytotoxicity toward MG-63 cells, and the HR Zn-1Mg-0.3Gd alloy displayed the highest cell viability among all three alloy extracts at 12.5% concentration. Overall, the HR Zn-1Mg-0.3Gd can be considered a promising biodegradable implant material for bone-implant materials owing to its high mechanical strength and ductility, suitable degradation rate, and satisfying biocompatibility. STATEMENT OF SIGNIFICANCE: In this work, Zn-1Mg-xGd (x = 0.1, 0.2, and 0.3 wt.%) alloys were developed by alloying with gadolinium (Gd) and hot-rolling, and their mechanical properties, corrosion behavior, hemolysis percentage, anticoagulant activity, and cytotoxicity were investigated for biodegradable implant application. Our findings demonstrated that the hot-rolled Zn-1Mg-0.3Gd alloy exhibit the highest ultimate tensile strength of 288.1 MPa, yield strength of 250.9 MPa, and elongation of 13.2%. Hot-rolled Zn-1Mg-xGd alloys show slowly increasing hemolysis percentages and decreasing activated partial thromboplastin time (APTT) values with increasing Gd addition. Extracts of hot-rolled Zn-1Mg-xGd alloys at a concentration of ≤ 25% show no cytotoxicity towards MG-63 cells, and Zn-1Mg-0.3Gd exhibit good cytocompatibility among all three alloys at a concentration of 12.5%.
Collapse
|
25
|
Amukarimi S, Mozafari M. Biodegradable Magnesium Biomaterials-Road to the Clinic. Bioengineering (Basel) 2022; 9:107. [PMID: 35324796 PMCID: PMC8945684 DOI: 10.3390/bioengineering9030107] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 02/24/2022] [Indexed: 01/09/2023] Open
Abstract
In recent decades, we have witnessed radical changes in the use of permanent biomaterials. The intrinsic ability of magnesium (Mg) and its alloys to degrade without releasing toxic degradation products has led to a vast range of applications in the biomedical field, including cardiovascular stents, musculoskeletal, and orthopedic applications. With the use of biodegradable Mg biomaterials, patients would not suffer second surgery and surgical pain anymore. Be that as it may, the main drawbacks of these biomaterials are the high corrosion rate and unexpected degradation in physiological environments. Since biodegradable Mg-based implants are expected to show controllable degradation and match the requirements of specific applications, various techniques, such as designing a magnesium alloy and modifying the surface characteristics, are employed to tailor the degradation rate. In this paper, some fundamentals and particular aspects of magnesium degradation in physiological environments are summarized, and approaches to control the degradation behavior of Mg-based biomaterials are presented.
Collapse
|
26
|
Su S, Tang Q, Qu D. In Vitro Study of Degradation and Cytocompatibility of Ceramics/PLA Composite Coating on Pure Zinc for Orthopedic Application. Front Bioeng Biotechnol 2022; 10:856986. [PMID: 35309984 PMCID: PMC8931491 DOI: 10.3389/fbioe.2022.856986] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 01/28/2022] [Indexed: 11/13/2022] Open
Abstract
Zinc and its alloys are considered to be next-generation materials for fabricating absorbable biomedical devices. However, cytotoxicity has been reported to be associated with rapid degradation. To address these issues, a composite coating (PLA/Li-OCP) consisting of CaHPO4 conversion coating (Ca-P) and polylactic acid (PLA) decorated with Li-octacalcium phosphate particles was constructed on pure zinc. The immersion tests showed that the presence of Ca-P coating and PLA/Li-OCP coating on pure zinc could reduce the pH value. Compared with Ca-P coating, the introduction of the PLA/Li-OCP film on the Ca-P-coated samples could enhance the corrosion resistance, and there was one order of magnitude decrease in the corrosion current density. The cytocompatibility assay suggested that the PLA/Li-OCP coating favored the cell viability and upregulated the expression of related osteogenic-genes including RUNX2, OCN, and BMP. Therefore, the presence of the PLA/Li-OCP coating on pure zinc could effectively improve the degradation rate and cytocompatibility of pure zinc.
Collapse
Affiliation(s)
- Shenghui Su
- Division of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Qiangqiang Tang
- School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
| | - Dongbin Qu
- Division of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, China
- Department of Orthopaedic Surgery, Zengcheng Branch of Nanfang Hospital, Southern Medical University, Guangzhou, China
- *Correspondence: Dongbin Qu,
| |
Collapse
|
27
|
Li H, Wang P, Lin G, Huang J. The role of rare earth elements in biodegradable metals: A review. Acta Biomater 2021; 129:33-42. [PMID: 34022465 DOI: 10.1016/j.actbio.2021.05.014] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 04/14/2021] [Accepted: 05/11/2021] [Indexed: 11/26/2022]
Abstract
Compared with non-degradable metals, biodegradable metals, as a new generation of medical metallic materials, do not require secondary, which reduces the pain and economic burden of patients. However, currently developed biodegradable metals, including iron-based alloys, magnesium-based alloys, and zinc-based alloys, have deficiencies in their corrosion rates and mechanical properties, which have severely restricted the clinical application of biodegradable metals. So there is an urgent need to improve their mechanical properties, degradation behaviors and biocompatibility. Alloying is an important way to modify biodegradable metal materials. Rare earth elements (REEs) as alloying elements in biodegradable metals have attracted a great deal of attention due to their unique atomic structure and properties. The present review summarizes the effects of rare earth elements on the mechanical properties, degradation behaviors, and biocompatibility of biodegradable metals. Moreover, future research directions of rare earth elements alloying biodegradable metals are also prospected. STATEMENT OF SIGNIFICANCE: As a new generation of biomedical metallic materials, biodegradable metals have become a hot research topic in recent years as they can degrade completely in human body and thus avoid further secondary surgery. However, these biodegradable metal systems have drawbacks in clinical applications. Alloying is an important method to improve the properties of biodegradable metals. Among the various alloying elements, Rare Earth alloying elements are usually considered due to their unique atomic structure and properties. The present review summarizes the recent research progress of Rare Earth alloying elements in biodegradable metals. The effects of the Rare Earth alloying elements on mechanical properties, biodegradation behavior and biocompatibility of biodegradable metals are presented and discussed in detail.
Collapse
|