Erlebach R, Pale U, Beck T, Markovic S, Seric M, David S, Keller E. Limitations of SpO 2 / FiO 2-ratio for classification and monitoring of acute respiratory distress syndrome-an observational cohort study. Crit Care 2025; 29:82. [PMID: 39972458 PMCID: PMC11837723 DOI: 10.1186/s13054-025-05317-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Accepted: 02/09/2025] [Indexed: 02/21/2025] Open
Abstract
BACKGROUND The ratio of pulse-oximetric peripheral oxygen saturation to fraction of inspired oxygen (SpO2/FiO2) has been proposed as additional hypoxemia criterion in a new global definition of acute respiratory distress syndrome (ARDS). This study aims to evaluate the clinical and theoretical limitations of the SpO2/FiO2-ratio when using it to classify patients with ARDS and to follow disease progression. METHODS Observational cohort study of ARDS patients from three high-resolution Intensive Care Unit databases, including our own database ICU Cockpit, MIMIC-IV (Version 3.0) and SICdb (Version 1.0.6). Patients with ARDS were identified based on the Berlin criteria or ICD 9/10-codes. Time-matched datapoints of SpO2, FiO2 and partial pressure of oxygen in arterial blood (PaO2) were created. Severity classification followed the thresholds for SpO2/FiO2 and PaO2/FiO2 of the newly proposed global definition. RESULTS Overall, 708 ARDS patients were included in the analysis. ARDS severity was misclassified by SpO2/FiO2 in 33% of datapoints, out of which 84% were classified as more severe. This can be partially explained by imprecision of SpO2 measurement and equation used to transform SpO2/FiO2 to PaO2/FiO2. A high dependence of SpO2/FiO2-ratio on FiO2 settings was found, leading to major treatment effect and limited capability for tracking change in ARDS severity, which was achieved in less than 20% of events. CONCLUSIONS The use of SpO2/FiO2 interchangeably with PaO2/FiO2 for severity classification and monitoring of ARDS is limited by its inadequate trending ability and high dependence on FiO2 settings, which may influence treatment decisions and patient selection in clinical trials.
Collapse
Affiliation(s)
- Rolf Erlebach
- Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland.
| | - Una Pale
- Neurocritical Care Unit, Department of Neurosurgery and Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Tilman Beck
- Neurocritical Care Unit, Department of Neurosurgery and Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Sasa Markovic
- Neurocritical Care Unit, Department of Neurosurgery and Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Marko Seric
- Neurocritical Care Unit, Department of Neurosurgery and Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Sascha David
- Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Emanuela Keller
- Neurocritical Care Unit, Department of Neurosurgery and Institute of Intensive Care Medicine, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Liu K, Ma XY, Xiao H, Gu WJ, Lyu J, Yin HY. Association between the ROX index and mortality in patients with acute hypoxemic respiratory failure: a retrospective cohort study. Respir Res 2024; 25:143. [PMID: 38553757 PMCID: PMC10981314 DOI: 10.1186/s12931-024-02771-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Accepted: 03/13/2024] [Indexed: 04/01/2024] Open
Abstract
BACKGROUND Although ROX index is frequently used to assess the efficacy of high-flow nasal cannula treatment in acute hypoxemic respiratory failure (AHRF) patients, the relationship between the ROX index and the mortality remains unclear. Therefore, a retrospective cohort study was conducted to evaluate the ability of the ROX index to predict mortality risk in patients with AHRF. METHOD Patients diagnosed with AHRF were extracted from the MIMIC-IV database and divided into four groups based on the ROX index quartiles. The primary outcome was 28-day mortality, while in-hospital mortality and follow-up mortality were secondary outcomes. To investigate the association between ROX index and mortality in AHRF patients, restricted cubic spline curve and COX proportional risk regression were utilized. RESULT A non-linear association (L-shaped) has been observed between the ROX index and mortality rate. When the ROX index is below 8.28, there is a notable decline in the 28-day mortality risk of patients as the ROX index increases (HR per SD, 0.858 [95%CI 0.794-0.928] P < 0.001). When the ROX index is above 8.28, no significant association was found between the ROX index and 28-day mortality. In contrast to the Q1 group, the mortality rates in the Q2, Q3, and Q4 groups had a substantial reduction (Q1 vs. Q2: HR, 0.749 [0.590-0.950] P = 0.017; Q3: HR, 0.711 [0.558-0.906] P = 0.006; Q4: HR, 0.641 [0.495-0.830] P < 0.001). CONCLUSION The ROX index serves as a valuable predictor of mortality risk in adult patients with AHRF, and that a lower ROX index is substantially associated with an increase in mortality.
Collapse
Affiliation(s)
- Kai Liu
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, 613 Huangpu Avenue West, Guangzhou, 510630, China
| | - Xin-Yi Ma
- The First Clinical Medical College, Southern Medical University, Guangzhou, China
| | - Hua Xiao
- Department of Nephrology, Shenzhen People's Hospital (The Second Clinical Medical College of Jinan University, The First Affiliated Hospital of Southern University of Science and Technology), Shenzhen, China
| | - Wan-Jie Gu
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, 613 Huangpu Avenue West, Guangzhou, 510630, China
| | - Jun Lyu
- Department of Clinical Research, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong Province, China.
| | - Hai-Yan Yin
- Department of Intensive Care Unit, The First Affiliated Hospital of Jinan University, 613 Huangpu Avenue West, Guangzhou, 510630, China.
| |
Collapse
|
3
|
Ryckman KK, Ramesh A, Cho H, Oltman SP, Rogers EE, Dagle JM, Jelliffe-Pawlowski LL. Evaluation of heparinized syringes for measuring newborn metabolites in neonates with a central arterial line. Clin Biochem 2022; 99:78-81. [PMID: 34688611 PMCID: PMC8671267 DOI: 10.1016/j.clinbiochem.2021.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 09/24/2021] [Accepted: 10/19/2021] [Indexed: 01/03/2023]
Abstract
Newborn metabolic screening is emerging as a novel method for predicting neonatal morbidity and mortality in neonates born very preterm (<32 weeks gestation). The purpose of our study was to determine if blood collected by an electrolyte-balanced dry lithium heparin syringe, as is routine for blood gas measurements, affects targeted metabolite and biomarker levels. Two blood samples (one collected with a heparinized syringe and the other with a non-heparinized syringe) were obtained at the same time from 20 infants with a central arterial line and tested for 49 metabolites and biomarkers using standard procedures for newborn screening. Overall, the median metabolite levels did not significantly differ by syringe type. However, there was wide variability, particularly for amino acids and immunoreactive trypsinogen, for individual paired samples and therefore, consideration should be given to sample collection when using these metabolites in prediction models of neonatal morbidity and mortality.
Collapse
Affiliation(s)
| | | | | | - Scott P Oltman
- University of California, San Francisco, Department of Epidemiology & Biostatistics,UCSF California Preterm Birth Initiative
| | - Elizabeth E Rogers
- UCSF California Preterm Birth Initiative,University of California San Francisco, Department of Pediatrics
| | | | - Laura L Jelliffe-Pawlowski
- University of California, San Francisco, Department of Epidemiology & Biostatistics,UCSF California Preterm Birth Initiative
| |
Collapse
|
4
|
Gonella S, Clari M, Conti A, Simionato L, Tassone C, Berchialla P, Campagna S. Interventions to reduce arterial puncture-related pain: A systematic review and meta-analysis. Int J Nurs Stud 2021; 126:104131. [PMID: 34922220 DOI: 10.1016/j.ijnurstu.2021.104131] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 10/29/2021] [Accepted: 11/01/2021] [Indexed: 12/15/2022]
Abstract
BACKGROUND Arterial puncture-related pain remains unaddressed across several clinical settings. Analgesic techniques are not routinely employed before arterial puncture despite the recommendation that local anesthesia be used, except in emergencies. A comprehensive review of interventions aimed at reducing arterial puncture-related pain and their potential effectiveness is lacking, and the benefit of some interventions is uncertain. OBJECTIVE To describe interventions aimed at reducing arterial puncture-related pain and provide an estimate of their effectiveness. DESIGN Systematic review and meta-analysis (PROSPERO no. CRD42020212299). DATA SOURCE(S) PubMed, CINAHL EBSCO, EMBASE, the Cochrane Database of Systematic Reviews, and Scopus were searched from their inception to 7 October 2020. No temporal or language limits were applied. METHODS Published, quantitative studies on interventions aimed at reducing arterial puncture-related pain among adults were included. Screening, quality appraisal, and data extraction were undertaken independently by two reviewers. Random effects meta-analyses were performed to assess the association between interventions aimed at reducing arterial puncture-related pain and patients' perceived pain using difference in means (MD) with 95% confidence intervals (CIs). A funnel plot and Egger test were used to assess publication bias. RESULTS The titles and abstracts of the 2446 identified articles were screened, and 43 and 31 studies were finally included in the systematic review and meta-analysis, respectively. Interventions to reduce arterial puncture-related pain included: topical anesthetics (n = 16), cryotherapy (n = 9), local anesthetic infiltration (n = 5), narrower needle gage (n = 5), ultrasound-guided procedure (n = 3), topical anesthetics combined with local anesthetic infiltration (n = 1), iontophoresis using anesthetics (n = 1), engineered blood gas syringe (n = 1), jet injector (n = 1), and local massage (n = 1). Topical anesthetics [MD -0.58, 95% CI -1.00, -0.15], cryotherapy [MD -1.13, 95% CI -1.72, -0.53], and local anesthetic infiltration [MD -1.13, 95% CI -1.72, -0.53] reduced arterial puncture-related pain. No benefit was found for narrower needle gage [MD -0.07, 95% CI -0.86, 0.71] or ultrasound-guided procedure [MD -1.74, 95% CI -3.51, 0.03]. No publication bias was detected. CONCLUSIONS Local anesthetic infiltration provided the greatest pain reduction and should be considered standard practice. Cryotherapy may be a safe, convenient alternative to local anesthetic infiltration. Topical anesthetics had limited benefit, and their lengthy time of onset makes them unsuitable for critical or emergency situations, though they may represent an option when comorbid conditions make cooling impossible. Caution must be used when interpreting these results, given the high risk of bias in the methods of included studies and the heterogeneity across the studies.
Collapse
Affiliation(s)
- Silvia Gonella
- Department of Public Health and Pediatrics, University of Torino, via Santena 5 bis, 10126 Torino, Italy; Azienda Ospedaliero Universitaria Città della Salute e della Scienza di Torino, Corso Bramante 88-90, 10126 Torino, Italy
| | - Marco Clari
- Department of Public Health and Pediatrics, University of Torino, via Santena 5 bis, 10126 Torino, Italy
| | - Alessio Conti
- Department of Public Health and Pediatrics, University of Torino, via Santena 5 bis, 10126 Torino, Italy.
| | - Laura Simionato
- Department of Clinical and Biological Sciences, University of Torino, via Santena 5 bis, 10126 Torino, Italy
| | - Cristina Tassone
- Department of Clinical and Biological Sciences, University of Torino, via Santena 5 bis, 10126 Torino, Italy
| | - Paola Berchialla
- Department of Clinical and Biological Sciences, University of Torino, via Santena 5 bis, 10126 Torino, Italy
| | - Sara Campagna
- Department of Public Health and Pediatrics, University of Torino, via Santena 5 bis, 10126 Torino, Italy
| |
Collapse
|
5
|
Reddy VK, Lavoie M, Verbeek JH, Pahwa M. Devices for preventing percutaneous exposure injuries caused by needles in healthcare personnel. Cochrane Database Syst Rev 2017; 11:CD009740. [PMID: 29190036 PMCID: PMC6491125 DOI: 10.1002/14651858.cd009740.pub3] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Percutaneous exposure injuries from devices used for blood collection or for injections expose healthcare workers to the risk of blood borne infections such as hepatitis B and C, and human immunodeficiency virus (HIV). Safety features such as shields or retractable needles can possibly contribute to the prevention of these injuries and it is important to evaluate their effectiveness. OBJECTIVES To determine the benefits and harms of safety medical devices aiming to prevent percutaneous exposure injuries caused by needles in healthcare personnel versus no intervention or alternative interventions. SEARCH METHODS We searched CENTRAL, MEDLINE, EMBASE, NHSEED, Science Citation Index Expanded, CINAHL, Nioshtic, CISdoc and PsycINFO (until 11 November 2016). SELECTION CRITERIA We included randomised controlled trials (RCT), controlled before and after studies (CBA) and interrupted time-series (ITS) designs of the effect of safety engineered medical devices on percutaneous exposure injuries in healthcare staff. DATA COLLECTION AND ANALYSIS Two of the authors independently assessed study eligibility and risk of bias and extracted data. We synthesized study results with a fixed-effect or random-effects model meta-analysis where appropriate. MAIN RESULTS We included six RCTs with 1838 participants, two cluster-RCTs with 795 participants and 73,454 patient days, five CBAs with approximately 22,000 participants and eleven ITS with an average of 13.8 data points. These studies evaluated safe modifications of blood collection systems, intravenous (IV) systems, injection systems, multiple devices, sharps containers and legislation on the implementation of safe devices. We estimated the needlestick injury (NSI) rate in the control groups to be about one to five NSIs per 1000 person-years. There were only two studies from low- or middle-income countries. The risk of bias was high in 20 of 24 studies. Safe blood collection systems:We found one RCT that found a safety engineered blood gas syringe having no considerable effect on NSIs (Relative Risk (RR) 0.2, 95% Confidence Interval (95% CI) 0.01 to 4.14, 550 patients, very low quality evidence). In one ITS study, safe blood collection systems decreased NSIs immediately after the introduction (effect size (ES) -6.9, 95% CI -9.5 to -4.2) but there was no further decrease over time (ES -1.2, 95% CI -2.5 to 0.1, very low quality evidence). Another ITS study evaluated an outdated recapping shield, which we did not consider further. Safe Intravenous systemsThere was very low quality evidence in two ITS studies that NSIs were reduced with the introduction of safe IV devices, whereas one RCT and one CBA study provided very low quality evidence of no effect. However, there was moderate quality evidence produced by four other RCT studies that these devices increased the number of blood splashes when the safety system had to be engaged actively (relative risk (RR) 1.6, 95% CI 1.08 to 2.36). In contrast there was low quality evidence produced by two RCTs of passive systems that showed no effect on blood splashes. Yet another RCT produced low quality evidence that a different safe active IV system also decreased the incidence of blood leakages. Safe injection devicesThere was very low quality evidence provided by one RCT and one CBA study showing that introduction of safe injection devices did not considerably change the NSI rate. One ITS study produced low quality evidence showing that the introduction of safe passive injection systems had no effect on NSI rate when compared to safe active injection systems. Multiple safe devicesThere was very low quality evidence from one CBA study and two ITS studies. According to the CBA study, the introduction of multiple safe devices resulted in a decrease in NSI,whereas the two ITS studies found no change. Safety containersOne CBA study produced very low quality evidence showing that the introduction of safety containers decreased NSI. However, two ITS studies evaluating the same intervention found inconsistent results. LegislationThere was low to moderate quality evidence in two ITS studies that introduction of legislation on the use of safety-engineered devices reduced the rate of NSIs among healthcare workers. There was also low quality evidence which showed a decrease in the trend over time for NSI rates.Twenty out of 24 studies had a high risk of bias and the lack of evidence of a beneficial effect could be due to both confounding and bias. This does not mean that these devices are not effective. AUTHORS' CONCLUSIONS For safe blood collection systems, we found very low quality evidence of inconsistent effects on NSIs. For safe passive intravenous systems, we found very low quality evidence of a decrease in NSI and a reduction in the incidence of blood leakage events but moderate quality evidence that active systems may increase exposure to blood. For safe injection needles, the introduction of multiple safety devices or the introduction of sharps containers the evidence was inconsistent or there was no clear evidence of a benefit. There was low to moderate quality evidence that introduction of legislation probably reduces NSI rates.More high-quality cluster-randomised controlled studies that include cost-effectiveness measures are needed, especially in countries where both NSIs and blood-borne infections are highly prevalent.
Collapse
Affiliation(s)
- Viraj K Reddy
- Finnish Institute of Occupational HealthCochrane Work Review GroupNeulaniementie 4KuopioFinland70101
| | - Marie‐Claude Lavoie
- University of Maryland Baltimore110 South Paca Street4th Floor, RM 4‐100BaltimoreMarylandUSA21201
| | - Jos H Verbeek
- Finnish Institute of Occupational HealthCochrane Work Review GroupNeulaniementie 4KuopioFinland70101
| | - Manisha Pahwa
- University of TorontoDalla Lana School of Public Health155 College Street, 6th floorTorontoONCanadaM5T 3M7
| | | |
Collapse
|
6
|
Hernández-Padilla JM, Granero-Molina J, Márquez-Hernández VV, Suthers F, Fernández-Sola C. Development and psychometric evaluation of the arterial puncture self-efficacy scale. NURSE EDUCATION TODAY 2016; 40:45-51. [PMID: 27125149 DOI: 10.1016/j.nedt.2016.02.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2015] [Revised: 01/13/2016] [Accepted: 02/04/2016] [Indexed: 06/05/2023]
Abstract
BACKGROUND Arterial puncture for arterial blood gases (ABG) analysis can be a risky, painful, difficult-to-perform procedure that is often insufficiently practised and generates stress and discomfort amongst patients and healthcare professionals. Self-efficacy is a key component in the acquisition of procedural skills. Therefore, professionals' self-efficacy in arterial puncture should be measured before attempting the procedure on real patients. OBJECTIVE To develop and psychometrically assess a self-efficacy scale in arterial puncture. DESIGN An observational cross-sectional design was used in this study. SETTING Faculty of Education Sciences, Nursing and Physiotherapy in a higher education institution in the south of Spain. PARTICIPANTS A convenience sample of 342 nursing students entered and completed the study. All participants met the following inclusion criteria: (1) ≥18years old and (2) enrolled in a nursing degree programme during the 2014/2015 academic year. Participants were 74% female (n=254) and their age ranged from 18 to 50, with a mean age of 21.74years (SD=5.14). METHOD The Arterial Puncture Self-Efficacy Scale (APSES) was developed and psychometrically tested. Reliability and content validity were studied. Predictive validity and concurrent validity assessed criterion validity. In addition, principal component analysis and known-group analysis evaluated construct validity. RESULTS Principal component analysis revealed the two-subscale structure of the final 22-item version of the Arterial Puncture Self-Efficacy Scale (APSES). A total Cronbach's alpha coefficient of 0.97 showed its high reliability. The APSES' content validity index was excellent (S-CVI/Ave=0.95). Predictive and concurrent validity analysis demonstrated the good criterion validity of the tool. Supporting the APSES' sensitivity and specificity, known-groups analysis evidenced significant differences (p<0.001) in self-efficacy levels between groups. CONCLUSION The APSES showed good psychometric properties for measuring self-efficacy in arterial puncture for ABG analysis.
Collapse
Affiliation(s)
- José Manuel Hernández-Padilla
- Adult, Child and Midwifery Department, School of Health and Education, Middlesex University, Hendon Campus, The Burroughs, NW4 4BT, London, United Kingdom.
| | - José Granero-Molina
- Nursing, Physiotherapy and Medicine Department, Faculty of Education Sciences, Nursing and Physiotherapy, University of Almeria, Spain; Faculty of Health Sciences, Universidad Autónoma de Chile, Temuco, Chile
| | - Verónica V Márquez-Hernández
- Nursing, Physiotherapy and Medicine Department, Faculty of Education Sciences, Nursing and Physiotherapy, University of Almeria, Spain
| | - Fiona Suthers
- Adult, Child and Midwifery Department, School of Health and Education, Middlesex University, Hendon Campus, The Burroughs, NW4 4BT, London, United Kingdom
| | - Cayetano Fernández-Sola
- Nursing, Physiotherapy and Medicine Department, Faculty of Education Sciences, Nursing and Physiotherapy, University of Almeria, Spain; Faculty of Health Sciences, Universidad Autónoma de Chile, Temuco, Chile
| |
Collapse
|
7
|
Chen W, Janz DR, Shaver CM, Bernard GR, Bastarache JA, Ware LB. Clinical Characteristics and Outcomes Are Similar in ARDS Diagnosed by Oxygen Saturation/Fio2 Ratio Compared With Pao2/Fio2 Ratio. Chest 2016; 148:1477-1483. [PMID: 26271028 DOI: 10.1378/chest.15-0169] [Citation(s) in RCA: 109] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Oxygen saturation as measured by pulse oximetry/Fio2 (SF) ratio is highly correlated with the Pao2/Fio2 (PF) ratio in patients with ARDS. However, it remains uncertain whether SF ratio can be substituted for PF ratio for diagnosis of ARDS and whether SF ratio might identify patients who are systemically different from patients diagnosed by PF ratio. METHODS We conducted a secondary analysis of a large observational prospective cohort study. Patients were eligible if they were admitted to the medical ICU and fulfilled the Berlin definition of ARDS with hypoxemia criteria using either the standard PF threshold (PF ratio ≤ 300) or a previously published SF threshold (SF ratio ≤ 315). RESULTS Of 362 patients with ARDS, 238 (66%) received a diagnosis by PF ratio and 124 (34%) by SF ratio. In a small group of patients who received diagnoses of ARDS by SF ratio who had arterial blood gas measurements on the same day (n = 10), the PF ratio did not meet ARDS criteria. There were no major differences in clinical characteristics or comorbidities between groups with the exception of APACHE (Acute Physiology and Chronic Health Evaluation) II scores, which were higher in the group diagnosed by PF ratio. However, this difference was no longer apparent when arterial blood gas-dependent variables (pH, Pao2) were removed from the APACHE II score. There were also no differences in clinical outcomes including duration of mechanical ventilation (mean, 7 days in both groups; P = .25), duration of ICU stay (mean, 10 days vs 9 days in PF ratio vs SF ratio; P = .26), or hospital mortality (36% in both groups, P = .9). CONCLUSIONS Patients with ARDS diagnosed by SF ratio have very similar clinical characteristics and outcomes compared with patients diagnosed by PF ratio. These findings suggest that SF ratio could be considered as a diagnostic tool for early enrollment into clinical trials.
Collapse
Affiliation(s)
- Wei Chen
- Division of Allergy, Pulmonary, and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA; Vanderbilt University School of Medicine, Nashville, TN; the Division of Pulmonary and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA; Chiayi Christian Hospital, Chiayi, Taiwan; the Department of Life Science, Louisiana State University School of Medicine, New Orleans, LA; National Chung Hsing University, Taichung, Taiwan; the College of Nursing, Louisiana State University School of Medicine, New Orleans, LA.
| | - David R Janz
- Da-Yeh University, Taichung, Taiwan; and the Section of Pulmonary and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA
| | - Ciara M Shaver
- Division of Allergy, Pulmonary, and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA
| | - Gordon R Bernard
- Division of Allergy, Pulmonary, and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA
| | - Julie A Bastarache
- Division of Allergy, Pulmonary, and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA
| | - Lorraine B Ware
- Division of Allergy, Pulmonary, and Critical Care Medicine, Louisiana State University School of Medicine, New Orleans, LA
| |
Collapse
|
8
|
Ibrahim I, Yau YW, Ong L, Chan YH, Kuan WS. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study. Acad Emerg Med 2015; 22:315-20. [PMID: 25731215 DOI: 10.1111/acem.12601] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2014] [Revised: 09/17/2014] [Accepted: 09/22/2014] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. METHODS In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. RESULTS Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p < 0.001). The rates of hemolysis and mean potassium value were greater in samples obtained using the insulin needle compared to the standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p < 0.001) and at 24 hours postprocedure (5.4% vs. 34.2%; p = 0.007). CONCLUSIONS Arterial punctures using insulin needles cause less pain and fewer procedural complications compared to standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample.
Collapse
Affiliation(s)
- Irwani Ibrahim
- The Emergency Medicine Department and Department of Surgery; National University Health System; Singapore
| | - Ying Wei Yau
- The Emergency Medicine Department and Department of Surgery; National University Health System; Singapore
| | - Lizhen Ong
- The Department of Laboratory Medicine; National University Health System; Singapore
| | - Yiong Huak Chan
- The Biostatistics Department; National University Health System; Singapore
| | - Win Sen Kuan
- The Emergency Medicine Department and Department of Surgery; National University Health System; Singapore
| |
Collapse
|