Beermann SE, Watkins VY, Frolova AI, Raghuraman N, Cahill AG. The relationship between maternal anemia and electronic fetal monitoring patterns.
Am J Obstet Gynecol 2023;
229:449.e1-449.e6. [PMID:
37086877 DOI:
10.1016/j.ajog.2023.04.018]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 03/29/2023] [Accepted: 04/14/2023] [Indexed: 04/24/2023]
Abstract
BACKGROUND
Anemia is a commonly diagnosed comorbidity in pregnancy that is associated with increased risk of maternal and neonatal complications. Recent data demonstrate that maternal anemia is associated with higher umbilical artery and umbilical vein O2 content at the time of delivery.
OBJECTIVE
This study aimed to examine the relationship between maternal anemia and electronic fetal monitoring patterns associated with fetal hypoxia.
STUDY DESIGN
This is a secondary analysis of a prospective cohort study of singleton term deliveries with cord gases and universal complete blood count collected on admission between 2010 and 2014. Maternal anemia was defined as hemoglobin ≤11.0 g/dL on admission. The primary outcome was a composite of high-risk category 2 electronic fetal monitoring features in the last 60 minutes before delivery (recurrent late and/or variable decelerations, minimal variability, tachycardia, or >1 prolonged deceleration); secondary outcomes were total deceleration area and total deceleration area >90th percentile. Of the 8580 patients in the original study, 8196 were included in the analysis. Outcomes were compared between patients with and without anemia. Multivariable logistic regression was used to adjust for potentially confounding factors, including hypertensive disorders of pregnancy and induction of labor.
RESULTS
Of the 8196 patients with complete blood count on admission and fetal monitoring data, 2672 (32.6%; 2672/8196) were anemic and 5524 (67.4%; 5524/8196) were not. Patients with anemia were significantly less likely to have composite high-risk category 2 features on electronic fetal monitoring (34.2% vs 32.0%; adjusted risk ratio, 0.93; 95% confidence interval, 0.86-0.99). Women with anemia also had decreased total deceleration area and were less likely to have total deceleration area >90th percentile (18.7% vs 16.2%; adjusted risk ratio, 0.85; 95% confidence interval, 0.77-0.94).
CONCLUSION
Patients with anemia are less likely to have high-risk category 2 electronic fetal monitoring features associated with fetal hypoxia. This finding is consistent with the association between maternal anemia and increased umbilical cord O2 content, and suggests that maternal anemia may be protective against intrapartum fetal hypoxia.
Collapse