1
|
Wang L, Fatemi M, Alizad A. Artificial intelligence in fetal brain imaging: Advancements, challenges, and multimodal approaches for biometric and structural analysis. Comput Biol Med 2025; 192:110312. [PMID: 40319756 DOI: 10.1016/j.compbiomed.2025.110312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2025] [Revised: 04/21/2025] [Accepted: 04/29/2025] [Indexed: 05/07/2025]
Abstract
Artificial intelligence (AI) is transforming fetal brain imaging by addressing key challenges in diagnostic accuracy, efficiency, and data integration in prenatal care. This review explores AI's application in enhancing fetal brain imaging through ultrasound (US) and magnetic resonance imaging (MRI), with a particular focus on multimodal integration to leverage their complementary strengths. By critically analyzing state-of-the-art AI methodologies, including deep learning frameworks and attention-based architectures, this study highlights significant advancements alongside persistent challenges. Notable barriers include the scarcity of diverse and high-quality datasets, computational inefficiencies, and ethical concerns surrounding data privacy and security. Special attention is given to multimodal approaches that integrate US and MRI, combining the accessibility and real-time imaging of US with the superior soft tissue contrast of MRI to improve diagnostic precision. Furthermore, this review emphasizes the transformative potential of AI in fostering clinical adoption through innovations such as real-time diagnostic tools and human-AI collaboration frameworks. By providing a comprehensive roadmap for future research and implementation, this study underscores AI's potential to redefine fetal imaging practices, enhance diagnostic accuracy, and ultimately improve perinatal care outcomes.
Collapse
Affiliation(s)
- Lulu Wang
- Department of Engineering, Reykjavík University, Reykjavík 101, Iceland; Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55902, USA; College of Science, Engineering and Technology, University of South Africa, Midrand, 1686, Gauteng, South Africa.
| | - Mostafa Fatemi
- Department of Physiology and Biomedical Engineering, Mayo Clinic College of Medicine and Science, Rochester, MN, 55902, USA
| | - Azra Alizad
- Department of Radiology, Mayo Clinic College of Medicine and Science, Rochester, MN, 55902, USA
| |
Collapse
|
2
|
Tadepalli K, Das A, Meena T, Roy S. Bridging gaps in artificial intelligence adoption for maternal-fetal and obstetric care: Unveiling transformative capabilities and challenges. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2025; 263:108682. [PMID: 40023965 DOI: 10.1016/j.cmpb.2025.108682] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 02/04/2025] [Accepted: 02/18/2025] [Indexed: 03/04/2025]
Abstract
PURPOSE This review aims to comprehensively explore the application of Artificial Intelligence (AI) to an area that has not been traditionally explored in depth: the continuum of maternal-fetal health. In doing so, the intent was to examine this physiologically continuous spectrum of mother and child health, as well as to highlight potential pitfalls, and suggest solutions for the same. METHOD A systematic search identified studies employing AI techniques for prediction, diagnosis, and decision support employing various modalities like imaging, electrophysiological signals and electronic health records in the domain of obstetrics and fetal health. In the selected articles then, AI applications in fetal morphology, gestational age assessment, congenital defect detection, fetal monitoring, placental analysis, and maternal physiological monitoring were critically examined both from the perspective of the domain and artificial intelligence. RESULT AI-driven solutions demonstrate promising capabilities in medical diagnostics and risk prediction, offering automation, improved accuracy, and the potential for personalized medicine. However, challenges regarding data availability, algorithmic transparency, and ethical considerations must be overcome to ensure responsible and effective clinical implementation. These challenges must be urgently addressed to ensure a domain as critical to public health as obstetrics and fetal health, is able to fully benefit from the gigantic strides made in the field of artificial intelligence. CONCLUSION Open access to relevant datasets is crucial for equitable progress in this critical public health domain. Integrating responsible and explainable AI, while addressing ethical considerations, is essential to maximize the public health benefits of AI-driven solutions in maternal-fetal care.
Collapse
Affiliation(s)
- Kalyan Tadepalli
- Sir HN Reliance Foundation Hospital, Girgaon, Mumbai, 400004, India; Artificial Intelligence & Data Science, Jio Institute, Navi Mumbai, 410206, India
| | - Abhijit Das
- Artificial Intelligence & Data Science, Jio Institute, Navi Mumbai, 410206, India
| | - Tanushree Meena
- Artificial Intelligence & Data Science, Jio Institute, Navi Mumbai, 410206, India
| | - Sudipta Roy
- Artificial Intelligence & Data Science, Jio Institute, Navi Mumbai, 410206, India.
| |
Collapse
|
3
|
Bouachba A, De Jesus Neves J, Royer E, Bartin R, Salomon LJ, Grevent D, Gorincour G. Artificial intelligence, radiomics and fetal ultrasound: review of literature and future perspectives. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2025; 65:281-291. [PMID: 40024623 DOI: 10.1002/uog.29172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/18/2024] [Accepted: 12/04/2024] [Indexed: 03/04/2025]
Affiliation(s)
- A Bouachba
- IMAGE2, Marseille, France
- Plateforme LUMIERE and URP 7328 FETUS, Université Paris Cité, Paris, France
| | - J De Jesus Neves
- IMAGE2, Marseille, France
- Plateforme LUMIERE and URP 7328 FETUS, Université Paris Cité, Paris, France
- ELSAN, Clinique Bouchard, Marseille, France
| | - E Royer
- Aix Marseille Université, Centre National de la Recherche Scientifique (CNRS), Center for Magnetic Resonance in Biology and Medicine (CRMBM), Marseille, France
| | - R Bartin
- Plateforme LUMIERE and URP 7328 FETUS, Université Paris Cité, Paris, France
| | - L J Salomon
- Plateforme LUMIERE and URP 7328 FETUS, Université Paris Cité, Paris, France
| | - D Grevent
- Plateforme LUMIERE and URP 7328 FETUS, Université Paris Cité, Paris, France
| | - G Gorincour
- IMAGE2, Marseille, France
- Plateforme LUMIERE and URP 7328 FETUS, Université Paris Cité, Paris, France
- ELSAN, Clinique Bouchard, Marseille, France
| |
Collapse
|
4
|
Chen Z, Chen M, Huang S, Wang Z, Zhang Y, Huang Y, Li W, Huang X. Texture-Based Classification of Fetal Growth Restriction From Intrauterine Neurosonographic Image. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2025; 44:177-188. [PMID: 39365033 DOI: 10.1002/jum.16594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 09/12/2024] [Accepted: 09/15/2024] [Indexed: 10/05/2024]
Abstract
OBJECTIVE Fetal growth restriction (FGR) is a condition where fetuses fail to reach their genetic potential for growth, posing a significant health challenge for newborns. The aim of this research was to explore the efficacy of texture-based analysis of neurosonographic images in identifying FGR in fetuses, which may provide a promising tool for early assessment of FGR. METHODS A retrospective analysis collected 100 intrauterine neurosonographic images from 50 FGR and 50 gestational age-appropriate fetuses. Using MaZda software, approximately 300 texture features were extracted from occipital white matter (OWM) and cerebellum of intrauterine neurosonographic images, respectively. Then 10 optimal features were separately selected by 3 algorithms, including the Fisher coefficient method, the method of minimizing classification error probability and average correlation coefficients, and the mutual information coefficient method. Further, the 10 statistically most significant features were selected from these sets to form the mixed feature set. After nonlinear discriminant analysis was performed to reduce feature dimensionality, the artificial neural network (ANN) classifier was conducted, respectively. RESULTS For OWM and cerebellum, a total of 11 and 14 statistically significant features were selected. When the mixed feature sets of OWM and cerebellum were applied to ANN classifier, classification accuracy were 90.00% (κ = 0.800; P < .001) and 93.00% (κ = 0.860; P < .001), and the receiver operating characteristic curve for identifying FGR showed an area under the curve of 0.82 and 0.87. CONCLUSIONS Texture analysis of fetal intrauterine neurosonographic images is a feasible and noninvasive strategy for evaluating FGR fetuses.
Collapse
Affiliation(s)
- Zehao Chen
- School of Computer Science and Technology, Dongguan University of Technology, Dongguan, China
| | - Mengjie Chen
- Department of Medical Ultrasonics, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, China
| | - Shiying Huang
- Department of Medical Ultrasonics, The Eighth Affiliated Hospital of Sun Yat-sen University, Shenzhen, China
| | - Zhongming Wang
- School of Computer Science and Technology, Dongguan University of Technology, Dongguan, China
| | - Yiheng Zhang
- School of Computer Science and Technology, Dongguan University of Technology, Dongguan, China
| | - Yuhan Huang
- School of Computer Science and Technology, Dongguan University of Technology, Dongguan, China
| | - Weiling Li
- School of Computer Science and Technology, Dongguan University of Technology, Dongguan, China
| | - Xiaowei Huang
- School of Computer Science and Technology, Dongguan University of Technology, Dongguan, China
| |
Collapse
|
5
|
Naz S, Noorani S, Jaffar Zaidi SA, Rahman AR, Sattar S, Das JK, Hoodbhoy Z. Use of artificial intelligence for gestational age estimation: a systematic review and meta-analysis. Front Glob Womens Health 2025; 6:1447579. [PMID: 39950139 PMCID: PMC11821921 DOI: 10.3389/fgwh.2025.1447579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2024] [Accepted: 01/15/2025] [Indexed: 02/16/2025] Open
Abstract
Introduction Estimating a reliable gestational age (GA) is essential in providing appropriate care during pregnancy. With advancements in data science, there are several publications on the use of artificial intelligence (AI) models to estimate GA using ultrasound (US) images. The aim of this meta-analysis is to assess the accuracy of AI models in assessing GA against US as the gold standard. Methods A literature search was performed in PubMed, CINAHL, Wiley Cochrane Library, Scopus, and Web of Science databases. Studies that reported use of AI models for GA estimation with US as the reference standard were included. Risk of bias assessment was performed using Quality Assessment for Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Mean error in GA was estimated using STATA version-17 and subgroup analysis on trimester of GA assessment, AI models, study design, and external validation was performed. Results Out of the 1,039 studies screened, 17 were included in the review, and of these 10 studies were included in the meta-analysis. Five (29%) studies were from high-income countries (HICs), four (24%) from upper-middle-income countries (UMICs), one (6%) from low-and middle-income countries (LMIC), and the remaining seven studies (41%) used data across different income regions. The pooled mean error in GA estimation based on 2D images (n = 6) and blind sweep videos (n = 4) was 4.32 days (95% CI: 2.82, 5.83; l 2: 97.95%) and 2.55 days (95% CI: -0.13, 5.23; l 2: 100%), respectively. On subgroup analysis based on 2D images, the mean error in GA estimation in the first trimester was 7.00 days (95% CI: 6.08, 7.92), 2.35 days (95% CI: 1.03, 3.67) in the second, and 4.30 days (95% CI: 4.10, 4.50) in the third trimester. In studies using deep learning for 2D images, those employing CNN reported a mean error of 5.11 days (95% CI: 1.85, 8.37) in gestational age estimation, while one using DNN indicated a mean error of 5.39 days (95% CI: 5.10, 5.68). Most studies exhibited an unclear or low risk of bias in various domains, including patient selection, index test, reference standard, flow and timings and applicability domain. Conclusion Preliminary experience with AI models shows good accuracy in estimating GA. This holds tremendous potential for pregnancy dating, especially in resource-poor settings where trained interpreters may be limited. Systematic Review Registration PROSPERO, identifier (CRD42022319966).
Collapse
Affiliation(s)
- Sabahat Naz
- Department of Pediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
| | - Sahir Noorani
- Department of Pediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
| | - Syed Ali Jaffar Zaidi
- Department of Pediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
| | - Abdu R. Rahman
- Institute for Global Health and Development, The Aga Khan University, Karachi, Pakistan
| | - Saima Sattar
- Department of Pediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
| | - Jai K. Das
- Department of Pediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
- Institute for Global Health and Development, The Aga Khan University, Karachi, Pakistan
| | - Zahra Hoodbhoy
- Department of Pediatrics and Child Health, The Aga Khan University, Karachi, Pakistan
| |
Collapse
|
6
|
Mlodawski J, Zmelonek-Znamirowska A, Mlodawska M, Detka K, Białek K, Swiercz G. Repeatability and reproducibility of artificial intelligence-acquired fetal brain measurements (SonoCNS) in the second and third trimesters of pregnancy. Sci Rep 2024; 14:25076. [PMID: 39443660 PMCID: PMC11500000 DOI: 10.1038/s41598-024-77313-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 10/21/2024] [Indexed: 10/25/2024] Open
Abstract
Artificial Intelligence (AI)-based algorithms are increasingly entering clinical practice, aiding in the assessment of fetal anatomy and biometry. One such tool for evaluating the fetal head and central nervous system structures is SonoCNS™, which delineates appropriate planes for measuring head circumference (HC), biparietal diameter (BPD), occipitofrontal diameter (OFD), transcerebellar diameter (TCD), width of the posterior horn of the lateral ventricle (Vp), and cisterna magna (CM) based on a 3D volume acquired at the level of the fetal head's thalamic plane. This study aimed to evaluate the intra- and interobserver variability of measurements obtained using this software. The study included 381 patients, 270 in their second trimester of pregnancy (70%) and 111 in the third trimester. Each patient underwent manual biometric measurements of the aforementioned structures and twice using the SonoCNS software. We calculated the intraobserver variability between the manual measurements and the average of the automated measurements, as well as the interobserver variability for automated measurements. We also compared the median examination time for manual and automated measurements. The interclass correlation coefficients (ICC) for interobserver and intraobserver variability for parameters BPD, HC, and OFD ranged from good to excellent reproducibility in the general population and subgroups (> 0.75). CM and Vp measurements, both in the general population and subgroups, fell into the category of moderate (0.5-0.75) and poor reproducibility (< 0.5). TCD measurements showed moderate (> 0.5) to good reproducibility (0.75-0.9), and OFD showed good and excellent reproducibility. The assessment of the biometry of fetal head structures using SonoCNS took an average of 63 s compared to 14 s for manual measurement (p < 0.001). The SonoCNS™ software is characterized by good to excellent reproducibility and repeatability in the measurement of fetal skull biometry (BPD, HC, and OFD), with poorer performance in measurements of intracranial structures (CM, Vp, TCD). Apart from biometric parameters, the software is useful in clinical practice for delineating appropriate planes from the acquired volume of the fetal head and shortening examination time.
Collapse
Affiliation(s)
- J Mlodawski
- Jan Kochanowski University in Kielce, Kielce, Poland.
- Provincial Combined Hospital in Kielce, Kielce, Poland.
| | - A Zmelonek-Znamirowska
- Jan Kochanowski University in Kielce, Kielce, Poland
- Provincial Combined Hospital in Kielce, Kielce, Poland
| | - M Mlodawska
- Jan Kochanowski University in Kielce, Kielce, Poland
- Provincial Combined Hospital in Kielce, Kielce, Poland
| | - K Detka
- Provincial Combined Hospital in Kielce, Kielce, Poland
| | - K Białek
- Jan Kochanowski University in Kielce, Kielce, Poland
- Provincial Combined Hospital in Kielce, Kielce, Poland
| | - G Swiercz
- Jan Kochanowski University in Kielce, Kielce, Poland
- Provincial Combined Hospital in Kielce, Kielce, Poland
| |
Collapse
|
7
|
Weichert J, Scharf JL. Advancements in Artificial Intelligence for Fetal Neurosonography: A Comprehensive Review. J Clin Med 2024; 13:5626. [PMID: 39337113 PMCID: PMC11432922 DOI: 10.3390/jcm13185626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 09/04/2024] [Accepted: 09/16/2024] [Indexed: 09/30/2024] Open
Abstract
The detailed sonographic assessment of the fetal neuroanatomy plays a crucial role in prenatal diagnosis, providing valuable insights into timely, well-coordinated fetal brain development and detecting even subtle anomalies that may impact neurodevelopmental outcomes. With recent advancements in artificial intelligence (AI) in general and medical imaging in particular, there has been growing interest in leveraging AI techniques to enhance the accuracy, efficiency, and clinical utility of fetal neurosonography. The paramount objective of this focusing review is to discuss the latest developments in AI applications in this field, focusing on image analysis, the automation of measurements, prediction models of neurodevelopmental outcomes, visualization techniques, and their integration into clinical routine.
Collapse
Affiliation(s)
- Jan Weichert
- Division of Prenatal Medicine, Department of Gynecology and Obstetrics, University Hospital of Schleswig-Holstein, Ratzeburger Allee 160, 23538 Luebeck, Germany;
- Elbe Center of Prenatal Medicine and Human Genetics, Willy-Brandt-Str. 1, 20457 Hamburg, Germany
| | - Jann Lennard Scharf
- Division of Prenatal Medicine, Department of Gynecology and Obstetrics, University Hospital of Schleswig-Holstein, Ratzeburger Allee 160, 23538 Luebeck, Germany;
| |
Collapse
|
8
|
Devisri B, Kavitha M. Fetal growth analysis from ultrasound videos based on different biometrics using optimal segmentation and hybrid classifier. Stat Med 2024; 43:1019-1047. [PMID: 38155152 DOI: 10.1002/sim.9995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/04/2023] [Accepted: 12/04/2023] [Indexed: 12/30/2023]
Abstract
Birth defects and their associated deaths, high health and financial costs of maternal care and associated morbidity are major contributors to infant mortality. If permitted by law, prenatal diagnosis allows for intrauterine care, more complicated hospital deliveries, and termination of pregnancy. During pregnancy, a set of measurements is commonly used to monitor the fetal health, including fetal head circumference, crown-rump length, abdominal circumference, and femur length. Because of the intricate interactions between the biological tissues and the US waves mother and fetus, analyzing fetal US images from a specialized perspective is difficult. Artifacts include acoustic shadows, speckle noise, motion blur, and missing borders. The fetus moves quickly, body structures close, and the weeks of pregnancy vary greatly. In this work, we propose a fetal growth analysis through US image of head circumference biometry using optimal segmentation and hybrid classifier. First, we introduce a hybrid whale with oppositional fruit fly optimization (WOFF) algorithm for optimal segmentation of segment fetal head which improves the detection accuracy. Next, an improved U-Net design is utilized for the hidden feature (head circumference biometry) extraction which extracts features from the segmented extraction. Then, we design a modified Boosting arithmetic optimization (MBAO) algorithm for feature optimization to selects optimal best features among multiple features for the reduction of data dimensionality issues. Furthermore, a hybrid deep learning technique called bi-directional LSTM with convolutional neural network (B-LSTM-CNN) for fetal growth analysis to compute the fetus growth and health. Finally, we validate our proposed method through the open benchmark datasets are HC18 (Ultrasound image) and oxford university research archive (ORA-data) (Ultrasound video frames). We compared the simulation results of our proposed algorithm with the existing state-of-art techniques in terms of various metrics.
Collapse
Affiliation(s)
- B Devisri
- Department of Electronics and communication Engineering, K. Ramakrishnan College of Technology, (Affiliated to Anna University Chennai), Trichy, India
| | - M Kavitha
- Department of Electronics and Communication Engineering, K. Ramakrishnan College of Technology, Trichy, India
| |
Collapse
|
9
|
Han X, Yu J, Yang X, Chen C, Zhou H, Qiu C, Cao Y, Zhang T, Peng M, Zhu G, Ni D, Zhang Y, Liu N. Artificial intelligence assistance for fetal development: evaluation of an automated software for biometry measurements in the mid-trimester. BMC Pregnancy Childbirth 2024; 24:158. [PMID: 38395822 PMCID: PMC10885506 DOI: 10.1186/s12884-024-06336-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2023] [Accepted: 02/08/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND This study presents CUPID, an advanced automated measurement software based on Artificial Intelligence (AI), designed to evaluate nine fetal biometric parameters in the mid-trimester. Our primary objective was to assess and compare the CUPID performance of experienced senior and junior radiologists. MATERIALS AND METHODS This prospective cross-sectional study was conducted at Shenzhen University General Hospital between September 2022 and June 2023, and focused on mid-trimester fetuses. All ultrasound images of the six standard planes, that enabled the evaluation of nine biometric measurements, were included to compare the performance of CUPID through subjective and objective assessments. RESULTS There were 642 fetuses with a mean (±SD) age of 22 ± 2.82 weeks at enrollment. In the subjective quality assessment, out of 642 images representing nine biometric measurements, 617-635 images (90.65-96.11%) of CUPID caliper placements were determined to be accurately placed and did not require any adjustments. Whereas, for the junior category, 447-691 images (69.63-92.06%) were determined to be accurately placed and did not require any adjustments. In the objective measurement indicators, across all nine biometric parameters and estimated fetal weight (EFW), the intra-class correlation coefficients (ICC) (0.843-0.990) and Pearson correlation coefficients (PCC) (0.765-0.978) between the senior radiologist and CUPID reflected good reliability compared with the ICC (0.306-0.937) and PCC (0.566-0.947) between the senior and junior radiologists. Additionally, the mean absolute error (MAE), percentage error (PE), and average error in days of gestation were lower between the senior and CUPID compared to the difference between the senior and junior radiologists. The specific differences are as follows: MAE (0.36-2.53 mm, 14.67 g) compared to (0.64- 8.13 mm, 38.05 g), PE (0.94-9.38%) compared to (1.58-16.04%), and average error in days (3.99-7.92 days) compared to (4.35-11.06 days). In the time-consuming task, CUPID only takes 0.05-0.07 s to measure nine biometric parameters, while senior and junior radiologists require 4.79-11.68 s and 4.95-13.44 s, respectively. CONCLUSIONS CUPID has proven to be highly accurate and efficient software for automatically measuring fetal biometry, gestational age, and fetal weight, providing a precise and fast tool for assessing fetal growth and development.
Collapse
Affiliation(s)
- Xuesong Han
- Department of Ultrasonography, Shenzhen University General Hospital, Shenzhen, Guangdong, China
| | - Junxuan Yu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Xin Yang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Chaoyu Chen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Han Zhou
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Chuangxin Qiu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Yan Cao
- Shenzhen RayShape Medical Technology Co., Ltd, Shenzhen, Guangdong, China
| | | | | | - Guiyao Zhu
- Department of Ultrasonography, Shenzhen University General Hospital, Shenzhen, Guangdong, China
| | - Dong Ni
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China
| | - Yuanji Zhang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, School of Biomedical Engineering, Shenzhen University Medical School, Shenzhen University, Shenzhen, Guangdong, China.
- Medical Ultrasound Image Computing (MUSIC) Lab, Shenzhen University, Shenzhen, Guangdong, China.
- Marshall Laboratory of Biomedical Engineering, Shenzhen University, Shenzhen, Guangdong, China.
| | - Nana Liu
- Department of Ultrasonography, Shenzhen University General Hospital, Shenzhen, Guangdong, China.
| |
Collapse
|
10
|
Dubey G, Srivastava S, Jayswal AK, Saraswat M, Singh P, Memoria M. Fetal Ultrasound Segmentation and Measurements Using Appearance and Shape Prior Based Density Regression with Deep CNN and Robust Ellipse Fitting. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024; 37:247-267. [PMID: 38343234 PMCID: PMC10976955 DOI: 10.1007/s10278-023-00908-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 03/02/2024]
Abstract
Accurately segmenting the structure of the fetal head (FH) and performing biometry measurements, including head circumference (HC) estimation, stands as a vital requirement for addressing abnormal fetal growth during pregnancy under the expertise of experienced radiologists using ultrasound (US) images. However, accurate segmentation and measurement is a challenging task due to image artifact, incomplete ellipse fitting, and fluctuations due to FH dimensions over different trimesters. Also, it is highly time-consuming due to the absence of specialized features, which leads to low segmentation accuracy. To address these challenging tasks, we propose an automatic density regression approach to incorporate appearance and shape priors into the deep learning-based network model (DR-ASPnet) with robust ellipse fitting using fetal US images. Initially, we employed multiple pre-processing steps to remove unwanted distortions, variable fluctuations, and a clear view of significant features from the US images. Then some form of augmentation operation is applied to increase the diversity of the dataset. Next, we proposed the hierarchical density regression deep convolutional neural network (HDR-DCNN) model, which involves three network models to determine the complex location of FH for accurate segmentation during the training and testing processes. Then, we used post-processing operations using contrast enhancement filtering with a morphological operation model to smooth the region and remove unnecessary artifacts from the segmentation results. After post-processing, we applied the smoothed segmented result to the robust ellipse fitting-based least square (REFLS) method for HC estimation. Experimental results of the DR-ASPnet model obtain 98.86% dice similarity coefficient (DSC) as segmentation accuracy, and it also obtains 1.67 mm absolute distance (AD) as measurement accuracy compared to other state-of-the-art methods. Finally, we achieved a 0.99 correlation coefficient (CC) in estimating the measured and predicted HC values on the HC18 dataset.
Collapse
Affiliation(s)
- Gaurav Dubey
- Department of Computer Science, KIET Group of Institutions, Delhi-NCR, Ghaziabad, U.P, India
| | | | | | - Mala Saraswat
- Department of Computer Science, Bennett University, Greater Noida, India
| | - Pooja Singh
- Shiv Nadar University, Greater Noida, Uttar Pradesh, India
| | - Minakshi Memoria
- CSE Department, UIT, Uttaranchal University, Dehradun, Uttarakhand, India
| |
Collapse
|
11
|
Medjedovic E, Stanojevic M, Jonuzovic-Prosic S, Ribic E, Begic Z, Cerovac A, Badnjevic A. Artificial intelligence as a new answer to old challenges in maternal-fetal medicine and obstetrics. Technol Health Care 2024; 32:1273-1287. [PMID: 38073356 DOI: 10.3233/thc-231482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/12/2024]
Abstract
BACKGROUND Following the latest trends in the development of artificial intelligence (AI), the possibility of processing an immense amount of data has created a breakthrough in the medical field. Practitioners can now utilize AI tools to advance diagnostic protocols and improve patient care. OBJECTIVE The aim of this article is to present the importance and modalities of AI in maternal-fetal medicine and obstetrics and its usefulness in daily clinical work and decision-making process. METHODS A comprehensive literature review was performed by searching PubMed for articles published from inception up until August 2023, including the search terms "artificial intelligence in obstetrics", "maternal-fetal medicine", and "machine learning" combined through Boolean operators. In addition, references lists of identified articles were further reviewed for inclusion. RESULTS According to recent research, AI has demonstrated remarkable potential in improving the accuracy and timeliness of diagnoses in maternal-fetal medicine and obstetrics, e.g., advancing perinatal ultrasound technique, monitoring fetal heart rate during labor, or predicting mode of delivery. The combination of AI and obstetric ultrasound can help optimize fetal ultrasound assessment by reducing examination time and improving diagnostic accuracy while reducing physician workload. CONCLUSION The integration of AI in maternal-fetal medicine and obstetrics has the potential to significantly improve patient outcomes, enhance healthcare efficiency, and individualized care plans. As technology evolves, AI algorithms are likely to become even more sophisticated. However, the successful implementation of AI in maternal-fetal medicine and obstetrics needs to address challenges related to interpretability and reliability.
Collapse
Affiliation(s)
- Edin Medjedovic
- Clinic of Gynecology and Obstetrics, Clinical Center University of Sarajevo, Sarajevo, Bosnia and Herzegovina
- Department of Gynecology, Obstetrics and Reproductive Medicine, School of Medicine, Sarajevo School of Science and Technology, Sarajevo, Bosnia and Herzegovina
| | - Milan Stanojevic
- Department of Obstetrics and Gynecology, University Hospital "Sveti Duh", Zagreb, Croatia
| | - Sabaheta Jonuzovic-Prosic
- Clinic of Gynecology and Obstetrics, Clinical Center University of Sarajevo, Sarajevo, Bosnia and Herzegovina
| | - Emina Ribic
- Public Institution Department for Health Care of Women and Maternity of Sarajevo Canton, Sarajevo, Bosnia and Herzegovina
| | - Zijo Begic
- Department of Cardiology, Pediatric Clinic, Clinical Center University of Sarajevo, Sarajevo, Bosnia and Herzegovina
| | - Anis Cerovac
- Department of Gynecology and Obstetrics Tesanj, General Hospital Tesanj, Bosnia and Herzegovina
| | - Almir Badnjevic
- International Burch University, Sarajevo, Bosnia and Herzegovina
- Genetics and Bioengineering Department, Faculty of Engineering and Natural Sciences, Sarajevo, Bosnia and Herzegovina
| |
Collapse
|
12
|
Karalis VD. The Integration of Artificial Intelligence into Clinical Practice. APPLIED BIOSCIENCES 2024; 3:14-44. [DOI: 10.3390/applbiosci3010002] [Citation(s) in RCA: 24] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
Abstract
The purpose of this literature review is to provide a fundamental synopsis of current research pertaining to artificial intelligence (AI) within the domain of clinical practice. Artificial intelligence has revolutionized the field of medicine and healthcare by providing innovative solutions to complex problems. One of the most important benefits of AI in clinical practice is its ability to investigate extensive volumes of data with efficiency and precision. This has led to the development of various applications that have improved patient outcomes and reduced the workload of healthcare professionals. AI can support doctors in making more accurate diagnoses and developing personalized treatment plans. Successful examples of AI applications are outlined for a series of medical specialties like cardiology, surgery, gastroenterology, pneumology, nephrology, urology, dermatology, orthopedics, neurology, gynecology, ophthalmology, pediatrics, hematology, and critically ill patients, as well as diagnostic methods. Special reference is made to legal and ethical considerations like accuracy, informed consent, privacy issues, data security, regulatory framework, product liability, explainability, and transparency. Finally, this review closes by critically appraising AI use in clinical practice and its future perspectives. However, it is also important to approach its development and implementation cautiously to ensure ethical considerations are met.
Collapse
Affiliation(s)
- Vangelis D. Karalis
- Department of Pharmacy, School of Health Sciences, National and Kapodistrian University of Athens, 15784 Athens, Greece
- Institute of Applied and Computational Mathematics, Foundation for Research and Technology Hellas (FORTH), 70013 Heraklion, Greece
| |
Collapse
|
13
|
Jost E, Kosian P, Jimenez Cruz J, Albarqouni S, Gembruch U, Strizek B, Recker F. Evolving the Era of 5D Ultrasound? A Systematic Literature Review on the Applications for Artificial Intelligence Ultrasound Imaging in Obstetrics and Gynecology. J Clin Med 2023; 12:6833. [PMID: 37959298 PMCID: PMC10649694 DOI: 10.3390/jcm12216833] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/17/2023] [Accepted: 10/25/2023] [Indexed: 11/15/2023] Open
Abstract
Artificial intelligence (AI) has gained prominence in medical imaging, particularly in obstetrics and gynecology (OB/GYN), where ultrasound (US) is the preferred method. It is considered cost effective and easily accessible but is time consuming and hindered by the need for specialized training. To overcome these limitations, AI models have been proposed for automated plane acquisition, anatomical measurements, and pathology detection. This study aims to overview recent literature on AI applications in OB/GYN US imaging, highlighting their benefits and limitations. For the methodology, a systematic literature search was performed in the PubMed and Cochrane Library databases. Matching abstracts were screened based on the PICOS (Participants, Intervention or Exposure, Comparison, Outcome, Study type) scheme. Articles with full text copies were distributed to the sections of OB/GYN and their research topics. As a result, this review includes 189 articles published from 1994 to 2023. Among these, 148 focus on obstetrics and 41 on gynecology. AI-assisted US applications span fetal biometry, echocardiography, or neurosonography, as well as the identification of adnexal and breast masses, and assessment of the endometrium and pelvic floor. To conclude, the applications for AI-assisted US in OB/GYN are abundant, especially in the subspecialty of obstetrics. However, while most studies focus on common application fields such as fetal biometry, this review outlines emerging and still experimental fields to promote further research.
Collapse
Affiliation(s)
- Elena Jost
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
| | - Philipp Kosian
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
| | - Jorge Jimenez Cruz
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
| | - Shadi Albarqouni
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
- Helmholtz AI, Helmholtz Munich, Ingolstädter Landstraße 1, 85764 Neuherberg, Germany
| | - Ulrich Gembruch
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
| | - Brigitte Strizek
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
| | - Florian Recker
- Department of Obstetrics and Gynecology, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany
| |
Collapse
|
14
|
Coronado-Gutiérrez D, Eixarch E, Monterde E, Matas I, Traversi P, Gratacós E, Bonet-Carne E, Burgos-Artizzu XP. Automatic Deep Learning-Based Pipeline for Automatic Delineation and Measurement of Fetal Brain Structures in Routine Mid-Trimester Ultrasound Images. Fetal Diagn Ther 2023; 50:480-490. [PMID: 37573787 DOI: 10.1159/000533203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 07/11/2023] [Indexed: 08/15/2023]
Abstract
INTRODUCTION The aim of this study was to develop a pipeline using state-of-the-art deep learning methods to automatically delineate and measure several of the most important brain structures in fetal brain ultrasound (US) images. METHODS The dataset was composed of 5,331 images of the fetal brain acquired during the routine mid-trimester US scan. Our proposed pipeline automatically performs the following three steps: brain plane classification (transventricular, transthalamic, or transcerebellar plane); brain structures delineation (9 different structures); and automatic measurement (from the structure delineations). The methods were trained on a subset of 4,331 images and each step was evaluated on the remaining 1,000 images. RESULTS Plane classification reached 98.6% average class accuracy. Brain structure delineation obtained an average pixel accuracy higher than 96% and a Jaccard index higher than 70%. Automatic measurements get an absolute error below 3.5% for the four standard head biometries (head circumference, biparietal diameter, occipitofrontal diameter, and cephalic index), 9% for transcerebellar diameter, 12% for cavum septi pellucidi ratio, and 26% for Sylvian fissure operculization degree. CONCLUSIONS The proposed pipeline shows the potential of deep learning methods to delineate fetal head and brain structures and obtain automatic measures of each anatomical standard plane acquired during routine fetal US examination.
Collapse
Affiliation(s)
- David Coronado-Gutiérrez
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain,
- Transmural Biotech S. L., Barcelona, Spain,
| | - Elisenda Eixarch
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
- Institut d'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
- Centre for Biomedical Research on Rare Diseases (CIBERER), Barcelona, Spain
| | - Elena Monterde
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
| | - Isabel Matas
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
| | - Paola Traversi
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
| | - Eduard Gratacós
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
- Institut d'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
- Centre for Biomedical Research on Rare Diseases (CIBERER), Barcelona, Spain
| | - Elisenda Bonet-Carne
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
- Institut d'Investigacions Biomèdiques August Pi I Sunyer (IDIBAPS), Barcelona, Spain
- Barcelona Tech, Universitat Politècnica de Catalunya, Barcelona, Spain
| | - Xavier P Burgos-Artizzu
- BCNatal | Fetal Medicine Research Center (Hospital Clínic and Hospital Sant Joan de Déu, University of Barcelona), Barcelona, Spain
| |
Collapse
|
15
|
Horgan R, Nehme L, Abuhamad A. Artificial intelligence in obstetric ultrasound: A scoping review. Prenat Diagn 2023; 43:1176-1219. [PMID: 37503802 DOI: 10.1002/pd.6411] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 06/05/2023] [Accepted: 07/17/2023] [Indexed: 07/29/2023]
Abstract
The objective is to summarize the current use of artificial intelligence (AI) in obstetric ultrasound. PubMed, Cochrane Library, and ClinicalTrials.gov databases were searched using the following keywords "neural networks", OR "artificial intelligence", OR "machine learning", OR "deep learning", AND "obstetrics", OR "obstetrical", OR "fetus", OR "foetus", OR "fetal", OR "foetal", OR "pregnancy", or "pregnant", AND "ultrasound" from inception through May 2022. The search was limited to the English language. Studies were eligible for inclusion if they described the use of AI in obstetric ultrasound. Obstetric ultrasound was defined as the process of obtaining ultrasound images of a fetus, amniotic fluid, or placenta. AI was defined as the use of neural networks, machine learning, or deep learning methods. The authors' search identified a total of 127 papers that fulfilled our inclusion criteria. The current uses of AI in obstetric ultrasound include first trimester pregnancy ultrasound, assessment of placenta, fetal biometry, fetal echocardiography, fetal neurosonography, assessment of fetal anatomy, and other uses including assessment of fetal lung maturity and screening for risk of adverse pregnancy outcomes. AI holds the potential to improve the ultrasound efficiency, pregnancy outcomes in low resource settings, detection of congenital malformations and prediction of adverse pregnancy outcomes.
Collapse
Affiliation(s)
- Rebecca Horgan
- Division of Maternal Fetal Medicine, Department of Obstetrics & Gynecology, Eastern Virginia Medical School, Norfolk, Virginia, USA
| | - Lea Nehme
- Division of Maternal Fetal Medicine, Department of Obstetrics & Gynecology, Eastern Virginia Medical School, Norfolk, Virginia, USA
| | - Alfred Abuhamad
- Division of Maternal Fetal Medicine, Department of Obstetrics & Gynecology, Eastern Virginia Medical School, Norfolk, Virginia, USA
| |
Collapse
|
16
|
Xiao S, Zhang J, Zhu Y, Zhang Z, Cao H, Xie M, Zhang L. Application and Progress of Artificial Intelligence in Fetal Ultrasound. J Clin Med 2023; 12:jcm12093298. [PMID: 37176738 PMCID: PMC10179567 DOI: 10.3390/jcm12093298] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 04/01/2023] [Accepted: 04/28/2023] [Indexed: 05/15/2023] Open
Abstract
Prenatal ultrasonography is the most crucial imaging modality during pregnancy. However, problems such as high fetal mobility, excessive maternal abdominal wall thickness, and inter-observer variability limit the development of traditional ultrasound in clinical applications. The combination of artificial intelligence (AI) and obstetric ultrasound may help optimize fetal ultrasound examination by shortening the examination time, reducing the physician's workload, and improving diagnostic accuracy. AI has been successfully applied to automatic fetal ultrasound standard plane detection, biometric parameter measurement, and disease diagnosis to facilitate conventional imaging approaches. In this review, we attempt to thoroughly review the applications and advantages of AI in prenatal fetal ultrasound and discuss the challenges and promises of this new field.
Collapse
Affiliation(s)
- Sushan Xiao
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Junmin Zhang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Ye Zhu
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Zisang Zhang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Haiyan Cao
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Mingxing Xie
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| | - Li Zhang
- Department of Ultrasound Medicine, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
- Clinical Research Center for Medical Imaging in Hubei Province, Wuhan 430022, China
- Hubei Province Key Laboratory of Molecular Imaging, Wuhan 430022, China
| |
Collapse
|
17
|
Lee LH, Bradburn E, Craik R, Yaqub M, Norris SA, Ismail LC, Ohuma EO, Barros FC, Lambert A, Carvalho M, Jaffer YA, Gravett M, Purwar M, Wu Q, Bertino E, Munim S, Min AM, Bhutta Z, Villar J, Kennedy SH, Noble JA, Papageorghiou AT. Machine learning for accurate estimation of fetal gestational age based on ultrasound images. NPJ Digit Med 2023; 6:36. [PMID: 36894653 PMCID: PMC9998590 DOI: 10.1038/s41746-023-00774-2] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Accepted: 02/07/2023] [Indexed: 03/11/2023] Open
Abstract
Accurate estimation of gestational age is an essential component of good obstetric care and informs clinical decision-making throughout pregnancy. As the date of the last menstrual period is often unknown or uncertain, ultrasound measurement of fetal size is currently the best method for estimating gestational age. The calculation assumes an average fetal size at each gestational age. The method is accurate in the first trimester, but less so in the second and third trimesters as growth deviates from the average and variation in fetal size increases. Consequently, fetal ultrasound late in pregnancy has a wide margin of error of at least ±2 weeks' gestation. Here, we utilise state-of-the-art machine learning methods to estimate gestational age using only image analysis of standard ultrasound planes, without any measurement information. The machine learning model is based on ultrasound images from two independent datasets: one for training and internal validation, and another for external validation. During validation, the model was blinded to the ground truth of gestational age (based on a reliable last menstrual period date and confirmatory first-trimester fetal crown rump length). We show that this approach compensates for increases in size variation and is even accurate in cases of intrauterine growth restriction. Our best machine-learning based model estimates gestational age with a mean absolute error of 3.0 (95% CI, 2.9-3.2) and 4.3 (95% CI, 4.1-4.5) days in the second and third trimesters, respectively, which outperforms current ultrasound-based clinical biometry at these gestational ages. Our method for dating the pregnancy in the second and third trimesters is, therefore, more accurate than published methods.
Collapse
Affiliation(s)
- Lok Hin Lee
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - Elizabeth Bradburn
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK
| | - Rachel Craik
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK
| | - Mohammad Yaqub
- Intelligent Ultrasound Ltd, Hodge House, Cardiff, CF10 1DY, UK
| | - Shane A Norris
- South African Medical Research Council Developmental Pathways for Health Research Unit, Department of Paediatrics & Child Health, University of the Witwatersrand, Johannesburg, South Africa
| | - Leila Cheikh Ismail
- College of Health Sciences, University of Sharjah, University City, United Arab Emirates
| | - Eric O Ohuma
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK.,Maternal, Adolescent, Reproductive & Child Health (MARCH) Centre, London School of Hygiene & Tropical Medicine, London, UK
| | - Fernando C Barros
- Programa de Pós-Graduação em Epidemiologia, Universidade Federal de Pelotas, Pelotas, Brazil.,Programa de Pós-Graduação em Saúde e Comportamento, Universidade Católica de Pelotas, Pelotas, Brazil
| | - Ann Lambert
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK
| | - Maria Carvalho
- Faculty of Health Sciences, Aga Khan University, Nairobi, Kenya
| | - Yasmin A Jaffer
- Department of Family & Community Health, Ministry of Health, Muscat, Oman
| | - Michael Gravett
- Departments of Obstetrics and Gynecology and of Global Health, University of Washington, Seattle, WA, USA
| | - Manorama Purwar
- Nagpur INTERGROWTH-21st Research Centre, Ketkar Hospital, Nagpur, India
| | - Qingqing Wu
- School of Public Health, Peking University, Beijing, China
| | - Enrico Bertino
- Dipartimento di Scienze Pediatriche e dell' Adolescenza, Struttura Complessa Direzione Universitaria Neonatologia, Università di Torino, Torino, Italy
| | - Shama Munim
- Department of Obstetrics & Gynaecology, Division of Women & Child Health, Aga Khan University, Karachi, Pakistan
| | - Aung Myat Min
- Shoklo Malaria Research Unit, Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Mae Sot, Tak, Thailand
| | - Zulfiqar Bhutta
- Department of Obstetrics & Gynaecology, Division of Women & Child Health, Aga Khan University, Karachi, Pakistan.,Center for Global Child Health, Hospital for Sick Children, Toronto, Canada
| | - Jose Villar
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK.,Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK
| | - Stephen H Kennedy
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK.,Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK
| | - J Alison Noble
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford, UK
| | - Aris T Papageorghiou
- Nuffield Department of Women's & Reproductive Health, University of Oxford, Oxford, UK. .,Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, UK.
| |
Collapse
|
18
|
Bastiaansen WAP, Klein S, Koning AHJ, Niessen WJ, Steegers-Theunissen RPM, Rousian M. Computational methods for the analysis of early-pregnancy brain ultrasonography: a systematic review. EBioMedicine 2023; 89:104466. [PMID: 36796233 PMCID: PMC9958260 DOI: 10.1016/j.ebiom.2023.104466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/09/2023] [Accepted: 01/23/2023] [Indexed: 02/16/2023] Open
Abstract
BACKGROUND Early screening of the brain is becoming routine clinical practice. Currently, this screening is performed by manual measurements and visual analysis, which is time-consuming and prone to errors. Computational methods may support this screening. Hence, the aim of this systematic review is to gain insight into future research directions needed to bring automated early-pregnancy ultrasound analysis of the human brain to clinical practice. METHODS We searched PubMed (Medline ALL Ovid), EMBASE, Web of Science Core Collection, Cochrane Central Register of Controlled Trials, and Google Scholar, from inception until June 2022. This study is registered in PROSPERO at CRD42020189888. Studies about computational methods for the analysis of human brain ultrasonography acquired before the 20th week of pregnancy were included. The key reported attributes were: level of automation, learning-based or not, the usage of clinical routine data depicting normal and abnormal brain development, public sharing of program source code and data, and analysis of the confounding factors. FINDINGS Our search identified 2575 studies, of which 55 were included. 76% used an automatic method, 62% a learning-based method, 45% used clinical routine data and in addition, for 13% the data depicted abnormal development. None of the studies shared publicly the program source code and only two studies shared the data. Finally, 35% did not analyse the influence of confounding factors. INTERPRETATION Our review showed an interest in automatic, learning-based methods. To bring these methods to clinical practice we recommend that studies: use routine clinical data depicting both normal and abnormal development, make their dataset and program source code publicly available, and be attentive to the influence of confounding factors. Introduction of automated computational methods for early-pregnancy brain ultrasonography will save valuable time during screening, and ultimately lead to better detection, treatment and prevention of neuro-developmental disorders. FUNDING The Erasmus MC Medical Research Advisor Committee (grant number: FB 379283).
Collapse
Affiliation(s)
- Wietske A P Bastiaansen
- Department of Obstetrics and Gynecology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands; Biomedical Imaging Group Rotterdam, Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, the Netherlands
| | - Stefan Klein
- Biomedical Imaging Group Rotterdam, Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, the Netherlands
| | - Anton H J Koning
- Department of Pathology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands
| | - Wiro J Niessen
- Biomedical Imaging Group Rotterdam, Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center, Rotterdam, the Netherlands
| | | | - Melek Rousian
- Department of Obstetrics and Gynecology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands.
| |
Collapse
|
19
|
Malani SN, Shrivastava D, Raka MS. A Comprehensive Review of the Role of Artificial Intelligence in Obstetrics and Gynecology. Cureus 2023; 15:e34891. [PMID: 36925982 PMCID: PMC10013256 DOI: 10.7759/cureus.34891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 02/12/2023] [Indexed: 03/18/2023] Open
Abstract
The exponential growth of artificial intelligence (AI) has fascinated its application in various fields and so in the field of healthcare. Technological advancements in theories and learning algorithms and the availability of processing through huge datasets have created a breakthrough in the medical field with computing systems. AI can potentially drive clinicians and practitioners with appropriate decisions in managing cases and reaching a diagnosis, so its application is extensively spread in the medical field. Thus, computerized algorithms have made predictions so simple and accurate. This is because AI can proffer information accurately even to many patients. Furthermore, the subsets of AI, namely, machine learning (ML) and deep learning (DL) methods, have aided in detecting complex patterns from huge datasets and using such patterns in making predictions. Despite numerous challenges, AI implementation in obstetrics and gynecology is found to have a spellbound development. Therefore, this review propounds exploring the implementation of AI in obstetrics and gynecology to improve the outcomes and clinical experience. In that context, the evolution and progress of AI, the role of AI in ultrasound diagnosis in distinct phases of pregnancy, clinical benefits, preterm birth postpartum period, and applications of AI in gynecology are elucidated in this review with future recommendations.
Collapse
Affiliation(s)
- Sagar N Malani
- Department of Obstetrics and Gynecology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Deepti Shrivastava
- Department of Obstetrics and Gynecology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Mayur S Raka
- Department of Obstetrics and Gynecology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| |
Collapse
|
20
|
Coronado-Gutiérrez D, Ganau S, Bargalló X, Úbeda B, Porta M, Sanfeliu E, Burgos-Artizzu XP. Quantitative ultrasound image analysis of axillary lymph nodes to differentiate malignancy from reactive benign changes due to COVID-19 vaccination. Eur J Radiol 2022; 154:110438. [PMID: 35820268 PMCID: PMC9259511 DOI: 10.1016/j.ejrad.2022.110438] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/23/2022] [Accepted: 07/05/2022] [Indexed: 11/27/2022]
Abstract
PURPOSE The aim of this study is to assess the potential of quantitative image analysis and machine learning techniques to differentiate between malignant lymph nodes and benign lymph nodes affected by reactive changes due to COVID-19 vaccination. METHOD In this institutional review board-approved retrospective study, we improved our previously published artificial intelligence model, by retraining it with newly collected images and testing its performance on images containing benign lymph nodes affected by COVID-19 vaccination. All the images were acquired and selected by specialized breast-imaging radiologists and the nature of each node (benign or malignant) was assessed through a strict clinical protocol using ultrasound-guided biopsies. RESULTS A total of 180 new images from 154 different patients were recruited: 71 images (10 cases and 61 controls) were used to retrain the old model and 109 images (36 cases and 73 controls) were used to evaluate its performance. The achieved accuracy of the proposed method was 92.7% with 77.8% sensitivity and 100% specificity at the optimal cut-off point. In comparison, the visual node inspection made by radiologists from ultrasound images reached 69.7% accuracy with 41.7% sensitivity and 83.6% specificity. CONCLUSIONS The results obtained in this study show the potential of the proposed techniques to differentiate between malignant lymph nodes and benign nodes affected by reactive changes due to COVID-19 vaccination. These techniques could be useful to non-invasively diagnose lymph node status in patients with suspicious reactive nodes, although larger multicenter studies are needed to confirm and validate the results.
Collapse
Affiliation(s)
- David Coronado-Gutiérrez
- Transmural Biotech S. L., Barcelona, Spain; BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic de Barcelona (University of Barcelona) and Hospital Sant Joan de Deu, Barcelona, Spain.
| | - Sergi Ganau
- Radiology Department, Hospital Clinic de Barcelona (University of Barcelona), Barcelona, Spain
| | - Xavier Bargalló
- Radiology Department, Hospital Clinic de Barcelona (University of Barcelona), Barcelona, Spain
| | - Belén Úbeda
- Radiology Department, Hospital Clinic de Barcelona (University of Barcelona), Barcelona, Spain
| | - Marta Porta
- Radiology Department, Hospital Clinic de Barcelona (University of Barcelona), Barcelona, Spain
| | - Esther Sanfeliu
- Radiology Department, Hospital Clinic de Barcelona (University of Barcelona), Barcelona, Spain
| | - Xavier P Burgos-Artizzu
- Transmural Biotech S. L., Barcelona, Spain; BCNatal - Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clínic de Barcelona (University of Barcelona) and Hospital Sant Joan de Deu, Barcelona, Spain
| |
Collapse
|
21
|
Self A, Daher L, Schlussel M, Roberts N, Ioannou C, Papageorghiou AT. Second and third trimester estimation of gestational age using ultrasound or maternal symphysis-fundal height measurements: A systematic review. BJOG 2022; 129:1447-1458. [PMID: 35157348 PMCID: PMC9545821 DOI: 10.1111/1471-0528.17123] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 01/19/2022] [Accepted: 01/24/2022] [Indexed: 01/10/2023]
Abstract
Many vulnerable women seek antenatal care late in pregnancy. How should gestational age be determined? We examine all available studies estimating GA >20 weeks. Ultrasound is much better than fundal height, and using cerebellar measurement appears to be the most accurate. Linked article: This article is commented on by Philip J. Steer, pp. 1459 in this issue. To view this minicommentary visit https://doi.org/10.1111/1471‐0528.17127 .
Collapse
Affiliation(s)
- Alice Self
- Nuffield Department of Women's & Reproductive HealthUniversity of OxfordOxfordUK
| | - Lama Daher
- Nuffield Department of Women's & Reproductive HealthUniversity of OxfordOxfordUK
| | - Michael Schlussel
- UK EQUATOR Centre, Centre for Statistics in Medicine, Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal SciencesUniversity of OxfordOxfordUK
| | - Nia Roberts
- Bodleian Health Care LibrariesUniversity of OxfordOxfordUK
| | - Christos Ioannou
- Nuffield Department of Women's & Reproductive HealthUniversity of OxfordOxfordUK
| | - Aris T. Papageorghiou
- Nuffield Department of Women's & Reproductive HealthUniversity of OxfordOxfordUK
- Oxford Maternal & Perinatal Health Institute, Green Templeton CollegeUniversity of OxfordOxfordUK
| |
Collapse
|
22
|
Generative Adversarial Networks to Improve Fetal Brain Fine-Grained Plane Classification. SENSORS 2021; 21:s21237975. [PMID: 34883977 PMCID: PMC8659720 DOI: 10.3390/s21237975] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 11/19/2021] [Accepted: 11/26/2021] [Indexed: 01/17/2023]
Abstract
Generative adversarial networks (GANs) have been recently applied to medical imaging on different modalities (MRI, CT, X-ray, etc). However there are not many applications on ultrasound modality as a data augmentation technique applied to downstream classification tasks. This study aims to explore and evaluate the generation of synthetic ultrasound fetal brain images via GANs and apply them to improve fetal brain ultrasound plane classification. State of the art GANs stylegan2-ada were applied to fetal brain image generation and GAN-based data augmentation classifiers were compared with baseline classifiers. Our experimental results show that using data generated by both GANs and classical augmentation strategies allows for increasing the accuracy and area under the curve score.
Collapse
|