1
|
Li G, Jin L, Weng Z, Jin X, Lin X, Chen S. Clinical utility of electrocardiographic voltage parameters for the diagnosis of hypertrophic cardiomyopathy. Front Cardiovasc Med 2024; 11:1354364. [PMID: 39386386 PMCID: PMC11462641 DOI: 10.3389/fcvm.2024.1354364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Accepted: 09/05/2024] [Indexed: 10/12/2024] Open
Abstract
Background While electrocardiographic parameters of hypertensive left ventricular hypertrophy (H-LVH) are well known, limited data are available regarding hypertrophic cardiomyopathy (HCM). This study was to assess the diagnostic value of electrocardiographic voltage parameters in HCM. Methods Included patients with HCM treated between March 2015 and May 2023. Voltage parameters (S-L, Cornell, Cornell product, Lewis, Peguero, and modified Cornell voltages) and echocardiography were evaluated. Receiver operating characteristic (ROC) curves were used to assess the diagnostic value of electrocardiogram in HCM. The multiple linear regression was conducted to analyze the correlation between electrocardiogram indicators and cardiac diastolic function. Results The highest sensitivity for HCM was Peguero voltage (70.4%; 88.6% specificity). The Peguero voltage had high sensitivity in male (63.8%) and female patients (84.9%), those aged <65 years (71.6%) and ≥65 years (68.3%), with non-apical HCM (AHCM) (76.7%), obstructive HCM (82.1%), and non-obstructive HCM (66.9%). The sensitivity of the S-L voltage was high in AHCM (72.2%). The sensitivity for HCM reached 88.7% when the S-L and Peguero voltages were combined. The modified Cornell index had the highest area under the curve (0.88, 95% CI: 0.84-0.91), and its optimal cutoff value was 2.05 mV in males (77.6% sensitivity and 74% specificity) and 1.935 mV in females (90.6% sensitivity and 91.4% specificity). Peguero voltage (beta = 0.154, P = 0.034) and SD (beta = 0.223 P = 0.004) were independently correlated with E/e', an index of left ventricular diastolic function. Conclusion The Peguero voltage had high sensitivity and specificity for detecting the presence of HCM. It was positively correlated with E/e' in patients with HCM. For AHCM, the S-L voltage was more advantageous. Combining the S-L voltage with the Peguero voltage further improves the sensitivity for HCM and thus could be used to improve the screening of HCM in clinical practice. The SD and modified Cornell voltage also had good diagnostic performance, especially in females.
Collapse
Affiliation(s)
- Gui Li
- Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China
| | - Lingdan Jin
- Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China
| | - Zhiyuan Weng
- Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China
| | - Xueqing Jin
- Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China
| | - Xiaoyan Lin
- Department of Ultrasound, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China
| | - Shuling Chen
- Department of Cardiology, The First Affiliated Hospital of Fujian Medical University, Fuzhou, Fujian, China
| |
Collapse
|
2
|
Braunisch MC, Gundel P, Werfel S, Mayer CC, Bauer A, Haller B, Günthner R, Lorenz G, Angermann S, Matschkal J, Schaller C, Holzmann-Littig C, Kemmner S, Mann J, Krieter A, Renders L, Wassertheurer S, Schmidt G, Heemann U, Malik M, Schmaderer C. Electrocardiographic parameters of left ventricular hypertrophy and prediction of mortality in hemodialysis patients. J Nephrol 2022; 35:233-244. [PMID: 34014512 PMCID: PMC8803820 DOI: 10.1007/s40620-021-01068-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Accepted: 05/09/2021] [Indexed: 11/09/2022]
Abstract
BACKGROUND In hemodialysis patients, left ventricular hypertrophy (LVH) contributes to high cardiovascular mortality. We examined cardiovascular mortality prediction by the recently proposed Peguero-Lo Presti voltage since it identifies more patients with electrocardiographic (ECG) LVH than Cornell or Sokolow-Lyon voltages. METHODS A total of 308 patients on hemodialysis underwent 24 h ECG recordings. LVH parameters were measured before and after dialysis. The primary endpoint of cardiovascular mortality was recorded during a median 3-year follow up. Risk prediction was assessed by Cox regression, both unadjusted and adjusted for the Charlson Comorbidity Index and the Cardiovascular Mortality Risk Score. RESULTS The Peguero-Lo Presti voltage identified with 21% the most patients with positive LVH criteria. All voltages significantly increased during dialysis. Factors such as ultrafiltration rate, Kt/V, body mass index, sex, and phosphate were the most relevant for these changes. During follow-up, 26 cardiovascular deaths occurred. Post-dialysis Peguero-Lo Presti cut-off as well as the Peguero-Lo Presti and Cornell voltages were independently associated with cardiovascular mortality in unadjusted and adjusted analysis. The Sokolow-Lyon voltage was not significantly associated with mortality. An optimal cut-off for the prediction of cardiovascular mortality was estimated at 1.38 mV for the Peguero-Lo Presti. CONCLUSIONS The post-dialysis Peguero-Lo Presti cut-off as well as the Peguero-Lo Presti and Cornell voltages allowed independent risk prediction of cardiovascular mortality in hemodialysis patients. Measuring the ECG LVH parameters after dialysis might allow a standardized interpretation as dialysis-specific factors influence the voltages.
Collapse
Affiliation(s)
- Matthias C Braunisch
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
| | - Peter Gundel
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
- Klinik für Innere Medizin 4, Schwerpunkt Nephrologie und Hypertensiologie, Klinikum Nürnberg, Nuremberg, Germany
| | - Stanislas Werfel
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Christopher C Mayer
- Center for Health and Bioresources, Biomedical Systems, AIT Austrian Institute of Technology GmbH, Vienna, Austria
| | - Axel Bauer
- University Hospital for Internal Medicine III, Medical University Innsbruck, Innsbruck, Austria
- Department of Cardiology, Munich University Clinic, DZHK (German Centre for Cardiovascular Research), Ludwig-Maximilians University, Munich, Germany
| | - Bernhard Haller
- Institute of Medical Informatics, Statistics and Epidemiology (IMedIS), School of Medicine, Klinikum Rechts der Isar, Technische Universität München, Munich, Germany
| | - Roman Günthner
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Georg Lorenz
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Susanne Angermann
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Julia Matschkal
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Carolin Schaller
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Christopher Holzmann-Littig
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
- TUM Medical Education Center, School of Medicine, Technical University of Munich, Munich, Germany
| | - Stephan Kemmner
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
- Transplant Center, University Hospital Munich, Ludwig-Maximillians University (LMU), Munich, Germany
| | - Johannes Mann
- Department of Nephrology, University of Erlangen-Nürnberg, Erlangen, Germany
- KfH Kidney Center Munich, Isoldenstraße 15, Munich, Germany
| | - Axel Krieter
- Nephrocare München-Ost, Rosenkavalierplatz 5, Munich, Germany
| | - Lutz Renders
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Siegfried Wassertheurer
- Center for Health and Bioresources, Biomedical Systems, AIT Austrian Institute of Technology GmbH, Vienna, Austria
| | - Georg Schmidt
- School of Medicine, Klinik für Innere Medizin I, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Uwe Heemann
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Marek Malik
- National Heart and Lung Institute, Imperial College London, London, UK
- Department of Internal Medicine and Cardiology, Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Christoph Schmaderer
- Department of Nephrology, School of Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
| |
Collapse
|
3
|
Guerreiro C, Azevedo P, Ladeiras-Lopes R, Ferreira N, Barbosa AR, Faria R, Almeida J, Primo J, Melica B, Braga P. Peguero-Lo Presti criteria for diagnosis of left ventricular hypertrophy: a cardiac magnetic resonance validation study. J Cardiovasc Med (Hagerstown) 2021; 21:437-443. [PMID: 32251077 DOI: 10.2459/jcm.0000000000000964] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
AIMS The diagnostic performance of the new Peguero-Lo Presti ECG criteria for left ventricular hypertrophy (LVH) has not been validated by cardiac magnetic resonance (CMR). The aim of this study was to evaluate and compare the diagnostic performance of Peguero-Lo Presti, Cornell and Sokolow--Lyon voltage criteria for LVH as defined by CMR in an all-comers European population. METHODS A total of 240 consecutive patients referred for CMR who had a concomitant electrocardiogram for review were evaluated. LVH group patients were defined according to the reference values for sex and age of left ventricular mass index (LVMi). A control group, adjusted by sex, was randomly selected from a population without LVH. We applied the ECG voltage criteria to both groups and evaluated their diagnostic accuracy. Diagnostic sensitivity and specificity were compared. RESULTS Two hundred and forty patients (mean age 63 years; 65% men) were divided into two groups (LVH n = 149; control n = 91). The main causes of LVH were hypertension (24.8%) and hypertrophic cardiomyopathy (21.5%). The remaining patients of this group had a diagnosis of dilated cardiomyopathy (14.8%), valvular heart disease (7.4%) and infiltrative cardiomyopathy (2.0%). Overall, the sensitivity for LVH diagnosis of the Peguero-Lo Presti criteria outperformed both the Cornell (47 vs. 29%, P < 0.001) and Sokolow--Lyon voltage criteria (vs. 25%, P < 0.001). The specificities of all the criteria were above 94%, without significant differences between them. CONCLUSION In an all-comers European population with LVH defined by CMR, the criteria of Peguero-Lo Presti showed increased sensitivity for this diagnosis, when compared with the Sokolow--Lyon and Cornell voltage criteria. As such, they could become the preferred ECG diagnostic tool when evaluating patients at risk for LVH.
Collapse
Affiliation(s)
| | - Pedro Azevedo
- Department of Cardiology, Centro Hospitalar Universitário do Algarve, Portugal
| | | | - Nuno Ferreira
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia
| | | | - Rita Faria
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia
| | - João Almeida
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia
| | - João Primo
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia
| | - Bruno Melica
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia
| | - Pedro Braga
- Department of Cardiology, Centro Hospitalar de Vila Nova de Gaia
| |
Collapse
|
4
|
Ricciardi D, Vetta G, Nenna A, Picarelli F, Creta A, Segreti A, Cavallaro C, Carpenito M, Gioia F, Di Belardino N, Lusini M, Chello M, Calabrese V, Grigioni F. Current diagnostic ECG criteria for left ventricular hypertrophy: is it time to change paradigm in the analysis of data? J Cardiovasc Med (Hagerstown) 2020; 21:128-133. [PMID: 31815851 DOI: 10.2459/jcm.0000000000000907] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Twelve-lead ECG represents the most common diagnostic tool in clinical cardiology and allows an immediate screening of left ventricular hypertrophy (LVH), but current criteria might have poor clinical usefulness in everyday clinical practice due to lack of sensitivity. METHODS The current study aims to review and compare the clinical performance of known ECG criteria of LVH in a real-life setting; 2134 patients had ECG and echocardiographic exams performed during the same hospitalization. All traces were retrospectively analysed, and the amplitudes of the waves were manually measured. Transthoracic echocardiography was considered as the gold standard to assess LVH. RESULTS LVH had a prevalence of 58%. Considering the diagnostic performance of ECG criteria for LVH, the Cornell voltage carried the best area under the receiver operating characteristic curve (0.678), while RaVF (R wave in aVF lead) had the poorer result (0.440). The R5/R6 criterion had the best sensitivity (60%), but with the worst specificity (37.4%). The 'Q or S aVR' had the best specificity (99.9%) but lacks sensitivity (0.80%). The Peguero Lo Presti criterion had a sensitivity of 42.3% and a specificity of 75.8%. The Cornell voltage and the Cornell product had similar area under the receiver operating characteristic curve values which were found to be significantly greater compared with other criteria. CONCLUSION Current ECG criteria of LVH have low sensitivity despite an acceptable specificity. Among these, Cornell voltage and Cornell product criteria were equally found to have a more accurate diagnostic performance compared with other criteria. To overcome the intrinsic limitations of the current ECG LVH criteria, a new paradigm in the analysis of electrocardiographic data might be necessary.
Collapse
Affiliation(s)
| | - Giampaolo Vetta
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Antonio Nenna
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | | | - Antonio Creta
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy.,Barts Heart Centre, St Bartholomew's Hospital, London, UK
| | - Andrea Segreti
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | | | | | - Flavio Gioia
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | | | - Mario Lusini
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Massimo Chello
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Vito Calabrese
- Heart Center, Università Campus Bio-Medico di Roma, Rome, Italy
| | | |
Collapse
|
5
|
You Z, He T, Ding Y, Yang L, Jiang X, Huang L. Predictive value of electrocardiographic left ventricular hypertrophy in the general population: A meta-analysis. J Electrocardiol 2020; 62:14-19. [PMID: 32745730 DOI: 10.1016/j.jelectrocard.2020.07.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 07/07/2020] [Accepted: 07/08/2020] [Indexed: 12/31/2022]
Abstract
BACKGROUND Conflicting results have been reported on the predictive value of the electrocardiographic left ventricular hypertrophy (LVH) in the general population. This meta-analysis sought to compare the predictive value of different electrocardiographic criteria of LVH in the general population. METHODS We comprehensively searched PubMed and Embase databases until May 9, 2020 to identify observational studies investigating the predictive value of different electrocardiographic criteria for LVH (Sokolow-Lyon voltage, Cornell voltage or Cornell product) in the general population. Outcome measures were major adverse cardiovascular events (MACEs), cardiovascular or all-cause mortality. RESULTS Ten studies enrolling 58,400 individuals were included. Comparison with and without electrocardiographic LVH, the pooled risk ratio (RR) of MACEs was 1.62 (95% confidence interval [CI] 1.40-1.89) for the Sokolow-Lyon voltage criteria, 1.70 (95% CI 1.27-2.29) for the Cornell voltage criteria, and 1.56 (95% CI 1.17-2) for the Cornell product criteria. The pooled RR of all-cause mortality was 1.47 (95% CI 1.10-1.97) for the Sokolow-Lyon voltage criteria and 1.87 (95% CI 1.29-2.71) for the Cornell voltage criteria. Furthermore, the pooled RR of cardiovascular mortality was 1.38 (95% CI 1.19-1.60) for the Sokolow-Lyon criteria, 1.66 (95% CI 1.24-2.33) for the Cornell voltage criteria, and 1.82 (95% CI 0.65-5.09) for the Cornell product criteria. CONCLUSIONS Different electrocardiographic criteria for evaluating LVH had a similar value in predicting MACEs among the general population. LVH detected by the Cornell voltage appeared to have a stronger predictive value in prediction of cardiovascular or all-cause mortality.
Collapse
Affiliation(s)
- Zhigang You
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, 330006, China
| | - Ting He
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, 330006, China
| | - Ying Ding
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, 330006, China
| | - Lu Yang
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, 330006, China
| | - Xinghua Jiang
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, 330006, China
| | - Lin Huang
- Department of Cardiovascular Medicine, The Second Affiliated Hospital of Nanchang University, 330006, China.
| |
Collapse
|
6
|
Zuo L, Hsi DH, Zhang L, Zhang Q, Shao H, Liu B, Lei C, Ye C, Meng X, Zhang G, Zhou M, Li J, He Y, Guo J, Liu L. Electrocardiographic QRS voltage amplitude improvement by intramyocardial radiofrequency ablation in patients with hypertrophic obstructive cardiomyopathy and one year follow up. J Electrocardiol 2020; 61:164-169. [PMID: 32721657 DOI: 10.1016/j.jelectrocard.2020.06.013] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 05/28/2020] [Accepted: 06/08/2020] [Indexed: 01/29/2023]
Abstract
OBJECTIVES This study aimed to determine whether the serial changes of the electrocardiogram is associated with regression of left ventricular hypertrophy (LVH) after Liwen procedure. BACKGROUND Clinical application of the echocardiography-guided percutaneous intramyocardial septal radiofrequency ablation (PIMSRA, Liwen procedure) is an innovative approach to treat hypertrophic obstructive cardiomyopathy (HOCM). METHODS We enrolled 30 consecutive patients with HOCM who had undergone Liwen procedure in our Hypertrophic Cardiomyopathy Center, from June 2016 to January 2018. Electrocardiography (ECG) and echocardiogram were performed before and after Liwen procedure, and at each follow-up (1-week, 1, 3, 6 months and 1 year). The Sokolow-Lyon index (SLi), Q wave, R wave, S wave amplitude of 12-lead ECG and interventricular septal (IVS) thickness, left ventricular mass index (LVMI) by echocardiograms were measured in each patient. The sum of the ECG QRS amplitude on each lead was calculated. The reduction of SLi and QRS amplitude were used as improvement index. RESULTS The ECG leads with most improvement rate of the QRS wave amplitude of all cases were V1 and V2, both at 90%. The QRS wave amplitude in V1 leads and SLi were positively correlated with IVS thickness and LVMI at baseline and 1 year after Liwen procedure, respectively. The reduction of IVS thickness, LVMI and QRS wave amplitude in leads V1 and V2 were significant at one month after ablation and the follow-up period. SLi was significantly decreased at 3 months during the observation period. Similarly, the improvement of ECG QRS wave amplitude after the Liwen procedure tracked the gradual thinning of the IVS and the changes of SLi reflected the regression of LVH. CONCLUSION The QRS wave amplitude reductions in lead V1 and SLi may be good indicators for evaluating the postoperative interventricular septal remodeling of the Liwen procedure.
Collapse
Affiliation(s)
- Lei Zuo
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - David H Hsi
- Heart&Vascular Institute, Stamford Hospital, Stamford, CT, USA
| | - Li Zhang
- Lankenau Institute for Medical Research, Sidney Kimmel Medical College of Thomas Jefferson University, Philadelphia, PA, USA
| | - Qin Zhang
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Hong Shao
- Department of Cardiology, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Bing Liu
- Department of Cardiology, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Changhui Lei
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Chuang Ye
- Department of Cardiology, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Xin Meng
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Guoqing Zhang
- Department of Ultrasound, The Affiliated Hospital of XiJing Hospital, Xi'an, Shaanxi, China
| | - Mengyao Zhou
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Jing Li
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China
| | - Yang He
- Xi'an Medical University, Xi'an, Shaanxi, China
| | - Jianying Guo
- Specialty Care Clinic, Xijing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China.
| | - Liwen Liu
- Hypertrophic Cardiomyopathy Center, Department of Ultrasound, XiJing Hospital, Fourth Military Medical University, Xi'an, Shaanxi, China.
| |
Collapse
|
7
|
Hedman K, Patti A, Moneghetti KJ, Hsu D, Christle JW, Ashley E, Hadley D, Haddad F, Froelicher V. Impact of the distance from the chest wall to the heart on surface ECG voltage in athletes. BMJ Open Sport Exerc Med 2020; 6:e000696. [PMID: 32201618 PMCID: PMC7061894 DOI: 10.1136/bmjsem-2019-000696] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/14/2020] [Indexed: 11/12/2022] Open
Abstract
Objective Available ECG criteria for detection of left ventricular (LV) hypertrophy have been reported to have limited diagnostic capability. Our goal was to describe how the distance between the chest wall and the left ventricle determined by echocardiography affected the relationship between ECG voltage and LV mass (LVM) in athletes. Methods We retrospectively evaluated digitised ECG data from college athletes undergoing routine echocardiography as part of their preparticipation evaluation. Along with LV mass and volume, we determined the chest wall–LV distance in the parasternal short-axis and long-axis views from two-dimensional transthoracic echocardiographic images and explored the relation with ECG QRS voltages in all leads, as well as summed voltages as included in six major ECG-LVH criteria. Results 239 athletes (43 women) were included (age 19±1 years). In men, greater LV–chest wall distance was associated with higher R-wave amplitudes in leads aVL and I (R=0.20 and R=0.25, both p<0.01), while in women greater distance was associated with higher R-amplitudes in V5 and V6 (R=0.42 and R=0.34, both p<0.01). In women, the chest wall–LV distance was the only variable independently (and positively) associated with R V5 voltage, while LVM, height and weight contributed to the relationship in men. Conclusions The chest wall–LV distance was weakly associated with ECG voltage in athletes. Inconsistent associations in men and women imply different intrathoracic factors affecting impedance and conductance between sexes. This may help explain the poor relationship between QRS voltage and LVM in athletes.
Collapse
Affiliation(s)
- Kristofer Hedman
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Department of Clinical Physiology and Department of Health, Medicine and Caring Sciences, Linköpings universitet, Linköping, Sweden
| | - Alessandro Patti
- Stanford Sports Cardiology, Stanford University, Stanford, California, USA.,Sport and Exercise Medicine Division, Department of Medicine, University of Padova, Padova, Italy
| | - Kegan J Moneghetti
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Stanford Sports Cardiology, Stanford University, Stanford, California, USA
| | - David Hsu
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Stanford Sports Cardiology, Stanford University, Stanford, California, USA
| | - Jeffrey W Christle
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Stanford Sports Cardiology, Stanford University, Stanford, California, USA
| | - Euan Ashley
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Stanford Sports Cardiology, Stanford University, Stanford, California, USA
| | | | - Francois Haddad
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Stanford Sports Cardiology, Stanford University, Stanford, California, USA
| | - Victor Froelicher
- Department of Medicine, Stanford Cardiovascular Institute, Stanford University, Stanford, California, USA.,Stanford Sports Cardiology, Stanford University, Stanford, California, USA
| |
Collapse
|
8
|
Hedman K, Moneghetti KJ, Hsu D, Christle JW, Patti A, Ashley E, Hadley D, Haddad F, Froelicher V. Limitations of Electrocardiography for Detecting Left Ventricular Hypertrophy or Concentric Remodeling in Athletes. Am J Med 2020; 133:123-132.e8. [PMID: 31738876 DOI: 10.1016/j.amjmed.2019.06.028] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 06/12/2019] [Accepted: 06/13/2019] [Indexed: 01/20/2023]
Abstract
BACKGROUND Electrocardiography (ECG) is used to screen for left ventricular hypertrophy (LVH), but common ECG-LVH criteria have been found less effective in athletes. The purpose of this study was to comprehensively evaluate the value of ECG for identifying athletes with LVH or a concentric cardiac phenotype. METHODS A retrospective analysis of 196 male Division I college athletes routinely screened with ECG and echocardiography within the Stanford Athletic Cardiovascular Screening Program was performed. Left-ventricular mass and volume were determined using echocardiography. LVH was defined as left ventricular mass (LVM) >102 g/m²; a concentric cardiac phenotype as LVM-to-volume (M/V) ≥1.05 g/mL. Twelve-lead electrocardiograms including high-resolution time intervals and QRS voltages were obtained. Thirty-seven previously published ECG-LVH criteria were applied, of which the majority have never been evaluated in athletes. C-statistics, including area under the receiver operating curve (AUC) and likelihood ratios were calculated. RESULTS ECG lead voltages were poorly associated with LVM (r = 0.18-0.30) and M/V (r = 0.15-0.25). The proportion of athletes with ECG-LVH was 0%-74% across criteria, with sensitivity and specificity ranging between 0% and 91% and 27% and 99.5%, respectively. The average AUC of the criteria in identifying the 11 athletes with LVH was 0.57 (95% confidence interval [CI] 0.56-0.59), and the average AUC for identifying the 8 athletes with a concentric phenotype was 0.59 (95% CI 0.56-0.62). CONCLUSION The diagnostic capacity of all ECG-LVH criteria were inadequate and, therefore, not clinically useful in screening for LVH or a concentric phenotype in athletes. This is probably due to the weak association between LVM and ECG voltage.
Collapse
Affiliation(s)
- Kristofer Hedman
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Cardiovascular Institute, Department of Medicine, Stanford University, Stanford, Calif; Department of Clinical Physiology and Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.
| | - Kegan J Moneghetti
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Sports Cardiology, Stanford University, Stanford, Calif
| | - David Hsu
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Sports Cardiology, Stanford University, Stanford, Calif
| | - Jeffrey W Christle
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Sports Cardiology, Stanford University, Stanford, Calif
| | - Alessandro Patti
- Stanford Sports Cardiology, Stanford University, Stanford, Calif; Sport and Exercise Medicine Division, Department of Medicine, University of Padova, Italy
| | - Euan Ashley
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Sports Cardiology, Stanford University, Stanford, Calif
| | | | - Francois Haddad
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Cardiovascular Institute, Department of Medicine, Stanford University, Stanford, Calif; Stanford Sports Cardiology, Stanford University, Stanford, Calif
| | - Victor Froelicher
- Division of Cardiovascular Medicine, Department of Medicine, Stanford University, Stanford, Calif; Stanford Sports Cardiology, Stanford University, Stanford, Calif
| |
Collapse
|
9
|
Assessment of a new electrocardiographic criterion for the diagnosis of left ventricle hypertrophy: A prospective validation study. North Clin Istanb 2019; 7:231-236. [PMID: 32478294 PMCID: PMC7251267 DOI: 10.14744/nci.2019.00907] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Accepted: 06/10/2019] [Indexed: 01/30/2023] Open
Abstract
OBJECTIVE: Many criteria have been developed to predict left ventricular hypertrophy using an electrocardiogram (ECG). However, one major common limitation of all has been their low sensitivity. Based on that, recently, a novel criterion has been proposed, which is believed to have higher sensitivity without a compromise in specificity. Therefore, in our study, we aimed to test this novel ECG criterion prospectively in large, unselected cardiac patients. METHODS: Patients who were referred to our echocardiography laboratory due to various etiologies were prospectively enrolled. The novel Peguero-Lo Presti criterion was assessed along with other established ECG criteria. The left ventricular mass index was calculated using echocardiography. The performance of each index was evaluated. RESULTS: Overall, 767 patients were enrolled in this study. The sensitivity and specificity of the Peguero-Lo Presti criterion were 17.5% and 94.5%, respectively. Although the highest sensitivity belonged to the Peguero-Lo Presti criterion, in ROC analysis, it showed modest predictive capability, which was similar to the established Cornell voltage criterion (AUC=0.64 [0.56–0.68 95% CI], p<0.01). CONCLUSION: Although this novel criterion had higher sensitivity, the overall performance was similar to the current indices. Further adjustments, particularly based on age and body mass index, may yield better results.
Collapse
|
10
|
Afify HMA, Waits GS, Ghoneum AD, Cao X, Li Y, Soliman EZ. Peguero Electrocardiographic Left Ventricular Hypertrophy Criteria and Risk of Mortality. Front Cardiovasc Med 2018; 5:75. [PMID: 30013976 PMCID: PMC6036297 DOI: 10.3389/fcvm.2018.00075] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Accepted: 05/31/2018] [Indexed: 11/13/2022] Open
Abstract
Background: Peguero electrocardiographic left ventricular hypertrophy (ECG-LVH) criteria are newly developed criteria that have shown better diagnostic performance than the traditional Cornell-voltage and Sokolow-Lyon criteria. However, prediction of poor outcomes rather than detection of increased left ventricular mass is becoming the primary use for ECG-LVH criteria which requires investigating any new ECG-LVH criteria in terms of prediction. Aims: To examine the prognostic significance of the newly developed Peguero ECG-LVH criteria. Methods: We compared the prognostic significance of Peguero ECG-LVH with Cornell-voltage and Sokolow-Lyon ECG-LVH criteria in 7,825 participants (age 59.8 ± 13.4 years; 52.7% women) from the third National Health and Nutrition Examination Survey who were free of major intraventricular conduction defects. ECG-LVH criteria were derived from digital ECG tracings processed at a central core laboratory. Results: At baseline, ECG-LVH was detected in 11.8% by Peguero; in 4.3% by Cornell voltage and in 6.4% by Sokolow-Lyon. During a median follow up of 13.8 years, 2,796 all-cause mortality events occurred. In multivariable models adjusted for demographics and cardiovascular risk factors, presence of Peguero ECG-LVH was associated with increased risk of all-cause mortality [HR (95% CI): 1.29 (1.16, 1.44)]. This association was not significantly different from the associations of Cornell voltage-LVH or Sokolow-Lyon LVH with all-cause mortality [HR (95%CI): 1.32 (1.12, 1.55) and 1.24 (1.07, 1.43), respectively; p-values for comparisons of these HRs with the HR of Peguero ECG-LVH 0.817 and 0.667, respectively]. Similar patterns of associations were observed with cardiovascular, ischemic heart disease and heart failure mortalities. Conclusion: Peguero ECG-LVH is predictive of increased risk of death similar to the traditional ECG-LVH criteria.
Collapse
Affiliation(s)
- Hesham M A Afify
- Epidemiological Cardiology Research Center, Wake Forest School of Medicine, Winston-Salem, NC, United States
| | - George S Waits
- Department of Internal Medicine, Wake Forest School of Medicine, Winston Salem, NC, United States
| | - Alia D Ghoneum
- Wake Forest School of Medicine, Winston Salem, NC, United States
| | - Xiangkun Cao
- Department of Internal Medicine, Wake Forest School of Medicine, Winston Salem, NC, United States
| | - Yabing Li
- Epidemiological Cardiology Research Center, Wake Forest School of Medicine, Winston-Salem, NC, United States
| | - Elsayed Z Soliman
- Epidemiological Cardiology Research Center, Wake Forest School of Medicine, Winston-Salem, NC, United States.,Department of Internal Medicine, Section on Cardiology, Wake Forest School of Medicine, Winston Salem, NC, United States
| |
Collapse
|