1
|
Tamizh Selvan G, Venkatachalam P. Potentials of cytokinesis blocked micronucleus assay in radiation triage and biological dosimetry. J Genet Eng Biotechnol 2024; 22:100409. [PMID: 39674629 PMCID: PMC11381789 DOI: 10.1016/j.jgeb.2024.100409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 02/04/2024] [Accepted: 08/06/2024] [Indexed: 09/11/2024]
Abstract
The measurement of micronucleus (MN) in the cytokinesis-block arrested binucleated cells has been extensively used as a biomarker in many radiation biology applications in specific biodosimetry. Following radiation casualties, medical management of exposed individuals begins with triage and biological dosimetry. The cytokinesis blocked micronucleus (CBMN) assay is the alternate for the gold standard dicentric chromosome assay in radiation dose assessment. In recent years, the CBMN assay has become well-validated and emerged as a method of choice for evaluating occupational and accidental exposures scenario. It is feasible due to its cost-effective, simple, and rapid dose assessment rather than a conventional chromosome aberration assay. PubMed search tool was used with keywords of MN, biodosimetry, radiotherapy and restricted to human samples. Since Fenech and Morely developed the assay, it has undergone many technical and technological reforms as a biomarker of various applications. In this review, we have abridged recent developments of the CBMN assay in radiation triage and biodosimetry, focusing on (a) the influence of variables on dose estimation, (b) the importance of baseline frequency and reported dose-response coefficient values among different laboratories, (c) inter-laboratory comparison and (d) its limitations and means to overcome them.
Collapse
Affiliation(s)
- G Tamizh Selvan
- Central Research Laboratory, K.S. Hegde Medical Academy, NITTE (Deemed to be University), Deralakatte, Mangalore, Karnataka, India.
| | - P Venkatachalam
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (Deemed to be University), Chennai, India
| |
Collapse
|
2
|
Beaton-Green LA, Mayenburg JM, Marro L, Hassan EM, Cuadros Sanchez S, Darwish R, Lachapelle S, Adam N, Burtt JJ, Van Den Hanenberg C, Rodrigues MA, Wang Q, Brenner DJ, Turner HC, Wilkins RC. Application of the Cytokinesis-Block Micronucleus Assay for High-Dose Exposures Using Imaging Flow Cytometry. Cytogenet Genome Res 2023; 163:131-142. [PMID: 37527635 DOI: 10.1159/000532124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 07/20/2023] [Indexed: 08/03/2023] Open
Abstract
The cytokinesis-block micronucleus assay is a well-established method to assess radiation-induced genetic damage in human cells. This assay has been adapted to imaging flow cytometry (IFC), allowing automated analysis of many cells, and eliminating the need to create microscope slides. Furthermore, to improve the efficiency of assay performance, a small-volume method previously developed was employed. Irradiated human blood samples were cultured, stained, and analyzed by IFC to produce images of the cells. Samples were run using both manual and 96-well plate automated acquisition. Multiple parameter-based image features were collected for each sample, and the results were compared to confirm that these acquisition methods are functionally identical. This paper details the multi-parametric analysis developed and the resulting calibration curves up to 10 Gy. The calibration curves were created using a quadratic random coefficient model with Poisson errors, as well as a logistic discriminant function. The curves were then validated with blinded, irradiated samples, using relative bias and relative mean square error. Overall, the accuracy of the dose estimates was adequate for triage dosimetry (within 1 Gy of the true dose) over 90% of the time for lower doses and about half the time for higher doses, with the lowest success rate between 5 and 6 Gy where the calibration curve reached its peak and there was the smallest change in MN/BNC with dose. This work describes the application of a novel multi-parametric analysis that fits the calibration curves and allows dose estimates up to 10 Gy, which were previously limited to 4 Gy. Furthermore, it demonstrates that the results from samples acquired manually and with the autosampler are functionally similar.
Collapse
Affiliation(s)
- Lindsay A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Jessica M Mayenburg
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Leonora Marro
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Eman M Hassan
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Sarita Cuadros Sanchez
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Riham Darwish
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Sylvie Lachapelle
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Nadine Adam
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Julie J Burtt
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - Cyndi Van Den Hanenberg
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | | | - Qi Wang
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - David J Brenner
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - Helen C Turner
- Center for Radiological Research, Columbia University Medical Center, New York, New York, USA
| | - Ruth C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| |
Collapse
|
3
|
Vishakh R, Suchetha Kumari N, Bhandary A, Shetty SS, Bhandary P, Tamizh Selvan G. Evaluating the role of cytokinesis-block micronucleus assay as a biomarker for oxidative stress-inducing DNA damage in type 2 diabetes mellitus patients. BENI-SUEF UNIVERSITY JOURNAL OF BASIC AND APPLIED SCIENCES 2023; 12:56. [DOI: 10.1186/s43088-023-00384-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 05/01/2023] [Indexed: 09/11/2024] Open
Abstract
Abstract
Background
Type 2 Diabetes Miletus (T2DM) is a common metabolic and lifestyle disorder leading to increased oxidative stress and DNA damage. The present study aims to evaluate the feasibility of utilizing the cytokinesis-block micronucleus assay (CBMN) as a biomarker for assessing the DNA damage induced due to variations in oxidative stress.
Methodology
The study group includes diabetic (n = 50) and non-diabetic (n = 50) subjects. The assays for the diabetes-like fasting blood sugar, postprandial glucose and hemoglobin A1c (HbA1c), lipid profiling, and serum ferritin level along with c-reactive protein (CRP) were applied. Further, the CBMN assay was performed to evaluate the micronuclei present in the lymphocytes of control and T2DM groups.
Results
Significant imbalance in the glycaemic index, dyslipidemia, increased ferritin levels, and CRP levels, with a significant increase of micronucleus frequency, was found in T2DM patients compared with the control group. Results suggest a trend of positive correlation between HbA1c and the micronuclei, indicating the assay’s potential importance as a biomarker for T2DM-induced risk assessment.
Conclusion
From the observed results, it can be suggested that the CBMN assay could be used to assess the risk of oxidative stress-induced DNA damage in high glycaemic index diabetic patients.
Collapse
|
4
|
Kannan N, Koshy T, Raavi V, Bhaskar E, Moorthy S, Pulivadula Mohanarangam VS, Srinivas Kondaveeti S, Visweswaran S, Perumal V. Candidate Gene Expression in Regional Population and Its Relevance for Radiation Triage. Cytogenet Genome Res 2023; 163:210-222. [PMID: 37253332 DOI: 10.1159/000531258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Accepted: 05/24/2023] [Indexed: 06/01/2023] Open
Abstract
Quantification of gene expression signatures has been substantiated as a potential and rapid marker for radiation triage and biodosimetry during nuclear emergencies. Similar to the established biodosimetry assays, the gene expression assay has drawbacks such as being highly dynamic and transient, not specific to ionizing radiation, and also influenced by confounding factors such as gender, health status, lifestyle, and inflammation. In view of that, prior knowledge of baseline expression of certain candidate genes in a population could complement the discrimination of the unexposed from the exposed individuals without the need for individual pre-exposure controls. We intended to establish a baseline expression of reported radiation-responsive genes such as CDKN1A, DDB2, FDXR, and PCNA in the blood samples of healthy human participants and then compare it with diabetic/hypertension participants (as a chronic inflammatory condition) drawn from south Indian population. Further, we have examined the appropriateness of the assay for radiation triage-like situations; i.e., the expression profiles of those genes were examined in the participants who underwent X-ray-based medical imaging. Acute inflammation induced by lipopolysaccharide exposure in the blood significantly increased the fold expression of those genes (p < 0.0001) compared to the control. Whereas the basal expression level of those genes among the participants with the inflammatory condition is marginally higher than those observed in the healthy participants; despite the excess, the fold increase in those genes between the groups did not differ significantly. Consistent with the inflammatory participants, the basal expression level of those genes in the blood sample of participants who received X-radiation during neuro-interventional and computed tomography imaging is marginally higher than those observed in the pre-exposure of respective groups. Nevertheless, the fold increase in those genes did not differ significantly as the fold change fell within the two folds. Thus, overall results suggest that the utility of CDKN1A, DDB2, FDXR, and PCNA gene expression for radiation triage specific after very low-dose radiation exposure needs to be interpreted with caution for a much more reliable triage.
Collapse
Affiliation(s)
- Nandhini Kannan
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Teena Koshy
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Venkateswarlu Raavi
- Department of Cell Biology and Molecular Genetics, Sri Devaraj Urs Academy of Higher Education and Research (Deemed to Be University), Kolar, India
| | - Emmanuel Bhaskar
- Department of General Medicine, SRMC&RI, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Swathy Moorthy
- Department of General Medicine, SRMC&RI, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Venkata Sai Pulivadula Mohanarangam
- Department of Radiology and Imaging Sciences, SRMC&RI, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Satish Srinivas Kondaveeti
- Department of Radiation Oncology, SRMC&RI, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Shangamithra Visweswaran
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| | - Venkatachalam Perumal
- Department of Human Genetics, Sri Ramachandra Institute of Higher Education and Research (Deemed to Be University), Chennai, India
| |
Collapse
|
5
|
Shen X, Chen Y, Li C, Yang F, Wen Z, Zheng J, Zhou Z. Rapid and automatic detection of micronuclei in binucleated lymphocytes image. Sci Rep 2022; 12:3913. [PMID: 35273270 PMCID: PMC8913785 DOI: 10.1038/s41598-022-07936-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Accepted: 02/28/2022] [Indexed: 11/09/2022] Open
Abstract
Cytokinesis block micronucleus (CBMN) assay is a widely used radiation biological dose estimation method. However, the subjectivity and the time-consuming nature of manual detection limits CBMN for rapid standard assay. The CBMN analysis is combined with a convolutional neural network to create a software for rapid standard automated detection of micronuclei in Giemsa stained binucleated lymphocytes images in this study. Cell acquisition, adhesive cell mass segmentation, cell type identification, and micronucleus counting are the four steps of the software's analysis workflow. Even when the cytoplasm is hazy, several micronuclei are joined to each other, or micronuclei are attached to the nucleus, this algorithm can swiftly and efficiently detect binucleated cells and micronuclei in a verification of 2000 images. In a test of 20 slides, the software reached a detection rate of 99.4% of manual detection in terms of binucleated cells, with a false positive rate of 14.7%. In terms of micronuclei detection, the software reached a detection rate of 115.1% of manual detection, with a 26.2% false positive rate. Each image analysis takes roughly 0.3 s, which is an order of magnitude faster than manual detection.
Collapse
Affiliation(s)
- Xiang Shen
- School of Mechanical Engineering and Automation, Beihang University, Beijing, 100083, China
| | - Ying Chen
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Chaowen Li
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Fucheng Yang
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Zhanbo Wen
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Jinlin Zheng
- Beijing Huironghe Technology Co., Ltd, Beijing, 101102, China
| | - Zhenggan Zhou
- School of Mechanical Engineering and Automation, Beihang University, Beijing, 100083, China.
| |
Collapse
|
6
|
Hülber T, Kocsis ZS, Németh J, Kis E, d'Errico F, Sáfrány G, Pesznyák C. Influence of sample preparation optimization on the accuracy of dose assessment of an automatic non-fluorescent MN scoring system. Int J Radiat Biol 2021; 97:1470-1484. [PMID: 34346832 DOI: 10.1080/09553002.2021.1962573] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
PURPOSE Automatizing the scoring of the cytokinesis-blocked micronucleus assay spares a lot of valuable time. The dose-effect relationship can be applied reliably for dose estimation if the quality of the slides is the same from the perspective of the used image processing algorithm. This aspect brings in additional requirements against the quality of the slides compared to the conventional visual scoring. MATERIALS AND METHODS An add-in software was created to the non-fluorescent RS-MN automatic MN scoring system which is capable of measuring quantitatively the degree of typical anomalies. The image processing is less reliable when the presence of these anomalies is more frequent. The behavior of the designed sample quality parameters (SQPs) was tested on in vitro irradiated peripheral blood samples (0, 1, and 2 Gy) obtained from a healthy donor and also on samples from patients undergoing low dose-rate brachytherapy. RESULTS We examined 20 different SQPs and identified two that are independent and correlate significantly with the error of the fully automatic MN frequency. One is related to the size of the cells and the other reflects the homogeneity of the environment. An equation was established which presents a connection between the error of the auto MN frequency and the SQPs. By adding a fourth cleaning step to the conventional sample preparation and changing the pre-dripping temperature of the slide, the SQP can be modified, and consequently, the sample quality can be improved. The gain in accuracy is 54 ± 10 MN per 1000 binucleated cells, which corresponds to the effects of 0.5 Gy. Around the lowest limit of detection (<0.5 Gy), it means a 50-100% drop in the error of dose, which is significant. With sample quality harmonization, the positive predictive value was raised to 80-93% depending on the dose. CONCLUSIONS With the technique described in this paper, the suitability for automated scoring of a micronucleus slide can be tested quantitatively and objectively. A method is presented with which in some cases the uncertainty of the assessed doses due to variance in sample quality can be decreased or if it is not possible its bias can be predicted. The proposed protocol leads to more reliable estimation of dose. The SQPs are designed in a way that they have the potential to be adapted to similar systems.
Collapse
Affiliation(s)
- Tímea Hülber
- Institute of Nuclear Techniques, Budapest University of Technology and Economics, Budapest, Hungary.,Radosys Ltd., Budapest, Hungary
| | - Zsuzsa S Kocsis
- Department of Radiobiology and Diagnostic Onco-Cytogenetics, Centre of Radiotherapy, National Institute of Oncology, Budapest, Hungary
| | | | - Enikõ Kis
- Department of Radiobiology and Radiohygiene, National Public Health Center, Budapest, Hungary
| | - Francesco d'Errico
- Department of Civil and Industrial Engineering, University of Pisa, Pisa, Italy
| | - Géza Sáfrány
- Department of Radiobiology and Radiohygiene, National Public Health Center, Budapest, Hungary
| | - Csilla Pesznyák
- Institute of Nuclear Techniques, Budapest University of Technology and Economics, Budapest, Hungary.,Centre of Radiotherapy, National Institute of Oncology, Budapest, Hungary
| |
Collapse
|
7
|
Hülber T, Kocsis ZS, Kis E, Sáfrány G, Pesznyák C. A scanning and image processing system with integrated design for automated micronucleus scoring. Int J Radiat Biol 2020; 96:628-641. [DOI: 10.1080/09553002.2020.1722863] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Tímea Hülber
- Institute of Nuclear Techniques, Budapest University of Technology and Economics, Budapest, Hungary
- Radosys Ltd, Budapest, Hungary
| | - Zsuzsa S. Kocsis
- Department of Radiobiology and Diagnostic Onco-Cytogenetics, Centre of Radiotherapy, National Institute of Oncology, Budapest, Hungary
| | - Enikő Kis
- Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - Géza Sáfrány
- Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary
| | - Csilla Pesznyák
- Institute of Nuclear Techniques, Budapest University of Technology and Economics, Budapest, Hungary
- Centre of Radiotherapy, National Institute of Oncology, Budapest, Hungary
| |
Collapse
|
8
|
Rodrigues MA, Beaton-Green LA, Wilkins RC, Fenech MF. The potential for complete automated scoring of the cytokinesis block micronucleus cytome assay using imaging flow cytometry. MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS 2018; 836:53-64. [PMID: 30389163 DOI: 10.1016/j.mrgentox.2018.05.003] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Revised: 03/27/2018] [Accepted: 05/03/2018] [Indexed: 12/21/2022]
Abstract
The lymphocyte Cytokinesis-Block Micronucleus (CBMN) assay was originally developed for the measurement of micronuclei (MN) exclusively in binucleated (BN) cells, which represent the population of cells that can express MN because they completed nuclear division. Recently the assay has evolved into a comprehensive cytome method to include biomarkers that measure chromosomal instability and cytotoxicity by quantification of nuclear buds (NBUDs), nucleoplasmic bridges (NPBs) and apoptotic/necrotic cells. Furthermore, enumeration of mono- and polynucleated cells allows for computation of the nuclear division index (NDI) to assess mitotic activity. Typically performed by manual microscopy, the CBMN cytome assay is laborious and subject to scorer bias and fatigue, leading to inter- and intra-scorer variability. Automated microscopy and conventional flow cytometry methods have been developed to automate scoring of the traditional and cytome versions of the assay. However, these methods have several limitations including the requirement to create high-quality microscope slides, lack of staining consistency and sub-optimal nuclear/cytoplasmic visualization. In the case of flow cytometry, stripping of the cytoplasmic membrane makes it impossible to measure MN in BN cells, calculate the NDI or to quantify apoptotic or necrotic cells. Moreover, the absence of cellular visualization using conventional flow cytometry, makes it impossible to quantify NBUDs and NPBs. In this review, we propose that imaging flow cytometry (IFC), which combines high resolution microscopy with flow cytometry, may overcome these limitations. We demonstrate that by using IFC, images from cells in suspension can be captured, removing the need for microscope slides and allowing visualization of intact cytoplasmic membranes and DNA content. Thus, mono-, bi- and polynucleated cells with and without MN can be rapidly and automatically identified and quantified. Finally, we present high-resolution cell images containing NBUDs and NPBs, illustrating that IFC possesses the potential for completely automated scoring of all components of the CBMN cytome assay.
Collapse
Affiliation(s)
| | - Lindsay A Beaton-Green
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Ontario, K1A 1C1, Canada
| | - Ruth C Wilkins
- Consumer and Clinical Radiation Protection Bureau, Health Canada, Ottawa, Ontario, K1A 1C1, Canada
| | | |
Collapse
|
9
|
Manivannan B, Kuppusamy T, Venkatesan S, Perumal V. A comparison of estimates of doses to radiotherapy patients obtained with the dicentric chromosome analysis and the γ-H2AX assay: Relevance to radiation triage. Appl Radiat Isot 2017; 131:1-7. [PMID: 29080427 DOI: 10.1016/j.apradiso.2017.10.031] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 10/14/2017] [Accepted: 10/14/2017] [Indexed: 11/18/2022]
Abstract
The γ-H2AX assay was investigated as an alternative to the time-consuming dicentric chromosome assay (DCA). Radiation doses to 25 radiotherapy patients were estimated in parallel by DCA and the γ-H2AX assay. The γ-H2AX assay yielded doses in line with the calculated equivalent whole body doses in 92% of the patients, whereas the success rate of DCA was only 76%. The result shows that the γ-H2AX assay can be effectively used as a rapid and more precise alternative to DCA.
Collapse
Affiliation(s)
- Bhavani Manivannan
- Department of Human Genetics, College of Biomedical Sciences, Technology and Research, Sri Ramachandra University, Porur, Chennai 600116, Tamil Nadu, India.
| | - Thayalan Kuppusamy
- Dr. Kamakshi Memorial Hospital Pvt. Ltd., Pallikaranai, Chennai 600100, Tamil Nadu, India.
| | - Srinivasan Venkatesan
- Dr. Kamakshi Memorial Hospital Pvt. Ltd., Pallikaranai, Chennai 600100, Tamil Nadu, India.
| | - Venkatachalam Perumal
- Department of Human Genetics, College of Biomedical Sciences, Technology and Research, Sri Ramachandra University, Porur, Chennai 600116, Tamil Nadu, India.
| |
Collapse
|
10
|
Rodrigues MA, Probst CE, Beaton-Green LA, Wilkins RC. THE EFFECT OF AN OPTIMIZED IMAGING FLOW CYTOMETRY ANALYSIS TEMPLATE ON SAMPLE THROUGHPUT IN THE REDUCED CULTURE CYTOKINESIS-BLOCK MICRONUCLEUS ASSAY. RADIATION PROTECTION DOSIMETRY 2016; 172:223-229. [PMID: 27421474 DOI: 10.1093/rpd/ncw160] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In cases of overexposure to ionizing radiation, the cytokinesis-block micronucleus (CBMN) assay can be performed in order to estimate the dose of radiation to an exposed individual. However, in the event of a large-scale radiation accident with many potentially exposed casualties, the assay must be able to generate accurate dose estimates to within ±0.5 Gy as quickly as possible. The assay has been adapted to, validated and optimized on the ImageStreamX imaging flow cytometer. The ease of running this automated version of the CBMN assay allowed investigation into the accuracy of dose estimates after reducing the volume of whole blood cultured to 200 µl and reducing the culture time to 48 h. The data analysis template used to identify binucleated lymphocyte cells (BNCs) and micronuclei (MN) has since been optimized to improve the sensitivity and specificity of BNC and MN detection. This paper presents a re-analysis of existing data using this optimized analysis template to demonstrate that dose estimations from blinded samples can be obtained to the same level of accuracy in a shorter data collection time. Here, we show that dose estimates from blinded samples were obtained to within ±0.5 Gy of the delivered dose when data collection time was reduced by 30 min at standard culture conditions and by 15 min at reduced culture conditions. Reducing data collection time while retaining the same level of accuracy in our imaging flow cytometry-based version of the CBMN assay results in higher throughput and further increases the relevancy of the CBMN assay as a radiation biodosimeter.
Collapse
Affiliation(s)
- M A Rodrigues
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario K1A 1C1, Canada
| | - C E Probst
- Amnis, a part of MilliporeSigma, 645 Elliott Avenue West, Suite 100, Seattle, WA 98119, USA
| | - L A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario K1A 1C1, Canada
| | - R C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario K1A 1C1, Canada
| |
Collapse
|
11
|
Bian D, Tsui JC, Repin M, Garty G, Turner H, Lawrence Yao Y, Brenner DJ. Liquid Handling Optimization in High-Throughput Biodosimetry Tool. J Med Device 2016; 10:0410071-4100710. [PMID: 27746851 DOI: 10.1115/1.4033600] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 04/13/2016] [Indexed: 11/08/2022] Open
Abstract
Due to the need of high-speed and efficient biodosimetric assays for triage and therapy in the event of radiological or nuclear attack, a robotically based automated biodosimetry tool (RABiT) has been developed over the past few years. Adapting the micronucleus assay from filter plates to V-shaped plates presented challenges in the liquid handling, namely, cell splashing out of the V-shaped well plate during the cell harvesting, poor cell distribution on the bottom of the image plate during the dispensing, and cell loss from the image plate during the aspiration in the liquid handling process. Experimental and numerical investigations were carried out to better understand the phenomena and mitigate the problems. Surface tension and contact angle among the fluids and the plate wall were accounted for in the discrete and multiphase numerical models. Experimental conditions were optimized based on the numerical results showing the relationship between nozzle speed and amount of splashed liquid, and the relationship between aspiration speed and number of escaped cells. Using these optimized parameters, numbers of micronuclei in binucleated cells showed the same dose dependence in the RABiT-prepared samples as those in the manually prepared ones. Micronucleus assay protocol was fully realized on RABiT.
Collapse
Affiliation(s)
- Dakai Bian
- Department of Mechanical Engineering, Columbia University, New York, NY 10027 e-mail:
| | - Jason C Tsui
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - Mikhail Repin
- Center for Radiological Research, Columbia University Medical Center, New York, NY 10032
| | - Guy Garty
- Center for Radiological Research, Columbia University Medical Center, New York, NY 10032
| | - Helen Turner
- Center for Radiological Research, Columbia University Medical Center, New York, NY 10032
| | - Y Lawrence Yao
- Department of Mechanical Engineering, Columbia University, New York, NY 10027
| | - David J Brenner
- Center for Radiological Research, Columbia University Medical Center, New York, NY 10032
| |
Collapse
|
12
|
Esposito G, Anello P, Pecchia I, Tabocchini MA, Campa A. Facility for gamma irradiations of cultured cells at low dose rates: design, physical characteristics and functioning. Appl Radiat Isot 2016; 115:227-234. [DOI: 10.1016/j.apradiso.2016.06.018] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2015] [Revised: 06/09/2016] [Accepted: 06/18/2016] [Indexed: 11/28/2022]
|
13
|
Rodrigues MA, Probst CE, Beaton-Green LA, Wilkins RC. Optimized automated data analysis for the cytokinesis-block micronucleus assay using imaging flow cytometry for high throughput radiation biodosimetry. Cytometry A 2016; 89:653-62. [PMID: 27272602 PMCID: PMC5089661 DOI: 10.1002/cyto.a.22887] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2015] [Revised: 05/05/2016] [Accepted: 05/10/2016] [Indexed: 01/23/2023]
Abstract
The cytokinesis-block micronucleus (CBMN) assay is a well-established technique that can be employed in triage radiation biodosimetry to estimate whole body doses of radiation to potentially exposed individuals through quantitation of the frequency of micronuclei (MN) in binucleated lymphocyte cells (BNCs). The assay has been partially automated using traditional microscope-based methods and most recently has been modified for application on the ImageStream(X) (IS(X) ) imaging flow cytometer. This modification has allowed for a similar number of BNCs to be automatically scored as compared to traditional microscopy in a much shorter time period. However, the MN frequency measured was much lower than both manual and automated slide-based methods of performing the assay. This work describes the optimized analysis template which implements newly developed functions in the IDEAS(®) data analysis software for the IS(X) that enhances specificity for BNCs and increases the frequency of scored MN. A new dose response calibration curve is presented in which the average rate of MN per BNC is of similar magnitude to those presented in the literature using automated CBMN slide scoring methods. In addition, dose estimates were generated for nine irradiated, blinded samples and were found to be within ±0.5 Gy of the delivered dose. Results demonstrate that the improved identification accuracy for MN and BNCs in the IS(X) -based version of the CBMN assay will translate to increased accuracy when estimating unknown radiation doses received by exposed individuals following large-scale radiological or nuclear emergencies. © 2016 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of ISAC.
Collapse
Affiliation(s)
- M A Rodrigues
- Amnis - MilliporeSigma, Seattle, WA, 98119.,Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - C E Probst
- Amnis - MilliporeSigma, Seattle, WA, 98119
| | - L A Beaton-Green
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| | - R C Wilkins
- Environmental and Radiation Health Sciences Directorate, Health Canada, Ottawa, Ontario, Canada
| |
Collapse
|
14
|
Venkateswarlu R, Tamizh SG, Bhavani M, Kumar A, Alok A, Karthik K, Kalra N, Vijayalakshmi J, Paul SFD, Chaudhury NK, Venkatachalam P. Mean frequency and relative fluorescence intensity measurement of γ-H2AX foci dose response in PBL exposed to γ-irradiation: An inter- and intra-laboratory comparison and its relevance for radiation triage. Cytometry A 2015; 87:1138-1146. [PMID: 26305808 DOI: 10.1002/cyto.a.22729] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2015] [Revised: 07/09/2015] [Accepted: 07/13/2015] [Indexed: 11/07/2022]
Abstract
Measurement of γ-H2AX protein changes in the peripheral blood lymphocytes (PBL) of individuals exposed to ionizing radiation is a simple, sensitive, and rapid assay for radiation triage and early marker of dose estimation. The qualitative and quantitative measurements of the protein changes were examined using flow cytometry and microscopy. Whole blood and isolated lymphocytes were exposed in vitro between 0.1 and 5 Gy doses of (60) Co γ-radiation at a dose rate of 1 Gy/min. Radiation induced γ-H2AX foci frequency (n = 3) and relative fluorescence intensity (n = 7) in PBL was measured at 0.5 and 2 hrs postexposure. The observed dose response for γ-H2AX foci frequency at both time points, for whole blood and isolated lymphocytes did not show any significant (P > 0.05) differences. However, when compared with γ-H2AX foci frequency scored manually (microscopy), the semiautomated analysis (captured images) showed a better correlation (r(2) = 0.918) than that obtained with automated (Metafer) scoring (r(2) = 0.690). It is noteworthy to mention that, the γ-H2AX foci frequency quantified using microscopy showed a dose dependent increase up to 2 Gy and the relative fluorescence intensity (RFI) measured with flow cytometry revealed an increase up to 5 Gy in the PBL exposed in vitro. Moreover, a better correlation was observed between the γ-H2AX foci frequency obtained by manual scoring and RFI (r(2) = 0.910). Kinetic studies showed that the γ-H2AX foci remain more or less unchanged up to 4 hrs and reduces gradually over 48 hrs of postexposure at 37°C. Further, inter and intra-laboratory comparisons showed consistency in the scoring of γ-H2AX foci frequency by manual and semiautomated scoring. The overall results suggest that measurement of γ-H2AX (microscopy and flow cytometry) should be employed within 4 to 6 hrs for a reliable dosimetry either by sharing the work load between the laboratories or investing more manpower; however, triage can be possible even up to 48 hrs of postirradiation.
Collapse
Affiliation(s)
- Raavi Venkateswarlu
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| | - Selvan G Tamizh
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| | - Manivannan Bhavani
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| | - Arun Kumar
- Chemical Radioprotector and Radiation Dosimetry Research Group, Institute of Nuclear Medicine and Allied Sciences, Timarpur, Delhi, India-110 054
| | - Amit Alok
- Chemical Radioprotector and Radiation Dosimetry Research Group, Institute of Nuclear Medicine and Allied Sciences, Timarpur, Delhi, India-110 054
| | - Kanagaraj Karthik
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| | - Namita Kalra
- Chemical Radioprotector and Radiation Dosimetry Research Group, Institute of Nuclear Medicine and Allied Sciences, Timarpur, Delhi, India-110 054
| | - J Vijayalakshmi
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| | - Solomon F D Paul
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| | - N K Chaudhury
- Chemical Radioprotector and Radiation Dosimetry Research Group, Institute of Nuclear Medicine and Allied Sciences, Timarpur, Delhi, India-110 054
| | - Perumal Venkatachalam
- Department of Human Genetics, Sri Ramachandra University, Porur, Chennai, 600 116, India
| |
Collapse
|
15
|
Yang J, Hu L, Xu J, Yang S. [Study of biological markers for radiation pretreatment of hematopoietic stem cell transplant recipients]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2015; 36:647-50. [PMID: 26462632 PMCID: PMC7348273 DOI: 10.3760/cma.j.issn.0253-2727.2015.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE To study the early biological parameter changes of blood and immune systems of mice after 60Co γ-ray irradiation in order to find sensitive and reliable biological dose markers for radiation pretreatment of hematopoietic stem cell transplant recipients. METHODS Pure strain BALB/c male mice were randomly divided into control group and three irradiation groups and absorbed doses of total body irradiation by ⁶⁰Co γ-ray were 0, 2, 4, 6 Gy, respectively. In 24h after irradiation, WBC counts and lymphocyte percentages of peripheral blood were determined by blood cell counting; polychromatic erythrocyte micronucleus(mn- PCE) of peripheral blood and bone marrow were observed by microscope after Giemsa staining; apoptosis rates of bone marrow, spleen, thymus cells were assayed by flow cytometry using Annexin Ⅴ and PI double staining. RESULTS Compared with the control group, WBC counts and lymphocyte percentages of peripheral blood in the irradiated groups significantly decreased with the increase of radiation doses(P<0.01),and their regression equations were E=0.1750D2-1.7440D+5.2020 and E=84.9390-3.4255D respectively. The mn-PCE of peripheral blood and bone marrow in the irradiated groups significantly increased with the increase of radiation doses(P<0.01), bone marrow mn-PCE was positively correlated with the radiation dose with regression equation as E=3.9725D+2.9700. The early apoptosis rates of bone marrow cells, spleen and thymus cells significantly increased with the increase of radiation doses(P<0.01), which were positively correlated with radiation doses, and their regression equations were E=3.42D + 8.36, E=3.0645D + 3.1840 and E=2.5620D + 2.5090 respectively. CONCLUSION Peripheral blood lymphocyte count and bone marrow mn-PCE rate were linearly correlated to radiation doses, which could be used as sensitive and reliable early biological markers of the radiation pretreatment recipients, and the doses of the radiation pretreatment recipients could be accurately judged according to their regression equations. The early apoptosis rates of bone marrow, spleen and thymus cells were positive linear correlation with the radiation doses, and their regression equations could be used to judge the degree of inhibition of the immune system for radiation pretreatment recipients.
Collapse
Affiliation(s)
- Jing Yang
- Suzhou City Center Blood Bank, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou 215006, China
| | - Lijun Hu
- Suzhou City Center Blood Bank, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou 215006, China
| | - Jun Xu
- Suzhou City Center Blood Bank, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou 215006, China
| | - Shuqin Yang
- Suzhou City Center Blood Bank, School of Radiation Medicine and Protection, Medical College of Soochow University, Suzhou 215006, China
| |
Collapse
|