1
|
Kalaai S, Most J, van Dun B, Kaptein BL, Tilman PBJ, Boonen B, Schotanus MGM. Less wear in deep-dished mobile compared to fixed bearing total knee arthroplasty of the same design at 5-year follow-up: a randomised controlled model-based Roentgen stereophotogrammetric analysis trial. Knee Surg Sports Traumatol Arthrosc 2023; 31:5137-5144. [PMID: 37796308 DOI: 10.1007/s00167-023-07584-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Accepted: 09/08/2023] [Indexed: 10/06/2023]
Abstract
PURPOSE The aim of this prospective randomised controlled study was to compare wear characteristics and functional outcome between deep-dished mobile bearing (MB) and fixed bearing (FB) cemented total knee arthroplasty (TKA). We hypothesised that deep-dished MB reduces polyethylene wear and improves patient-reported outcome measures. METHODS A total of 50 patients were randomised to receive a MB or FB tibia component of the same cemented TKA design. Patients were evaluated over a 5-year follow-up period. Medial and lateral wear were assessed using model-based Roentgen Stereophotogrammetric Analysis (RSA) and compared with the direct postoperative minimal joint space measurement. Functional outcome was assessed by the clinician-derived KSS and OKS, WOMAC, LEAS, and FJS-12. All data were derived using a general linear mixed model. RESULTS At 5-year follow-up, decreased wear in the MB compared to the FB group was observed on the lateral side (0.07 ± 0.17 mm, p = 0.026), but not on the medial side (0.31 ± 0.055 mm, p = 0.665). Functional outcomes improved with a statistical significant effect over time, with no significant differences between groups (all p > 0.17). CONCLUSION This model-based RSA study with 5-year follow-up showed that cemented deep-dished MB reduced lateral polyethylene wear as compared to FB in a single TKA system, whilst clinical outcomes were comparable. Longer follow-up is needed to establish clinical implications of these altered wear patterns and determine type of wear. LEVEL OF EVIDENCE Level 1 randomised controlled trial.
Collapse
Affiliation(s)
- S Kalaai
- Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands.
- Department of Surgery, Diakonessenhuis Utrecht, Utrecht, The Netherlands.
| | - J Most
- Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands
- School of Care and Public Health Research Institute, Faculty of Health, Medicine and Life Sciences, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - B van Dun
- Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands
- Department of Orthopaedic Surgery and Traumatology, Imelda Hospital, Bonheiden, Belgium
| | - B L Kaptein
- Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - P B J Tilman
- Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands
| | - B Boonen
- Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands
- School of Care and Public Health Research Institute, Faculty of Health, Medicine and Life Sciences, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - M G M Schotanus
- Department of Orthopaedic Surgery and Traumatology, Zuyderland Medical Center, Sittard-Geleen, The Netherlands
- School of Care and Public Health Research Institute, Faculty of Health, Medicine and Life Sciences, Maastricht University Medical Center+, Maastricht, The Netherlands
| |
Collapse
|
2
|
Matz J, Lanting BA, Howard JL. Understanding the patellofemoral joint in total knee arthroplasty. Can J Surg 2019; 62:57-65. [PMID: 30693747 DOI: 10.1503/cjs.001617] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Total knee arthroplasty (TKA) is one of the most successful procedures in orthopedic surgery. Nevertheless, postoperative patellofemoral complications remain a challenging problem, affecting a substantial proportion of patients. Complications involving the patellofemoral joint (PFJ) can occur in both resurfaced and nonresurfaced patellae. Types of PFJ complications include anterior knee pain, maltracking, fracture, avascular necrosis and patellar clunk. The causes of patellofemoral complications can be categorized into patient-, surgeon- and implant-related factors. Patient characteristics such as female sex, young age, depression and increased body mass index have been linked with increased complications. Important technical considerations to avoid complications include achieving appropriate rotational alignment of the femoral and tibial components, maintaining joint line height, medializing the patellar button and avoiding “overstuffing” the PFJ. Component design features such as conformity, shape and depth of the femoral trochlea have also been shown to be important. Although the cause of patellofemoral complications after TKA may sometimes be unknown, it remains important to minimize errors that can lead to these complications.
Collapse
Affiliation(s)
- Jacob Matz
- From the Division of Orthopedic Surgery, London Health Sciences Centre, London, Ont. (Matz, Lanting, Howard)
| | - Brent A. Lanting
- From the Division of Orthopedic Surgery, London Health Sciences Centre, London, Ont. (Matz, Lanting, Howard)
| | - James L. Howard
- From the Division of Orthopedic Surgery, London Health Sciences Centre, London, Ont. (Matz, Lanting, Howard)
| |
Collapse
|
3
|
|
4
|
Schotanus MGM, Pilot P, Kaptein BL, Draijer WF, Tilman PBJ, Vos R, Kort NP. No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial. Knee Surg Sports Traumatol Arthrosc 2017; 25:2978-2985. [PMID: 27120194 DOI: 10.1007/s00167-016-4138-6] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2015] [Accepted: 04/14/2016] [Indexed: 11/29/2022]
Abstract
PURPOSE A concern that arises with any new prosthesis is whether it will achieve satisfactory long-term implant stability. The gold standard of assessing the quality of fixation in a new or relatively new implant is to undertake a randomized controlled trial using radiostereometric analysis. It was hypothesized that both mobile-bearing total knee arthroplasty and fixed-bearing total knee arthroplasty have comparable migration patterns at 2-year follow-up. This study investigated two types of cemented total knee arthroplasty, the mobile- or fixed-bearing variant from the same family with use of radiostereometric analysis. METHODS This prospective, patient-blinded, randomized, controlled trial was designed to investigate early migration of the tibia component after two years of follow-up with use of radiostereometric analysis. A total of 50 patients were randomized to receive a mobile- or fixed-bearing TKA from the same family. Patients were evaluated during 2-year follow-up, including radiostereometric analysis, physical and clinical examination and patient reported outcome measures (PROMs). RESULTS At two-year follow-up, the mean (±SD) maximum total point motion (MTPM) in the fixed-bearing group was 0.82 (±1.16) versus 0.92 mm (±0.64) in the mobile-bearing group (p = n.s) with the largest migration seen during the first 6 weeks (0.45 ± 0.32 vs. 0.54 ± 0.30). The clinical outcome and PROMs significantly improved within each group, not between both groups. CONCLUSIONS Measuring early micromotion is useful for predicting clinical loosening that can lead to revision. The results of this study demonstrate that early migration of the mobile-bearing is similar to that of the fixed-bearing component at two years and was mainly seen in the first weeks after implantation. LEVEL OF EVIDENCE Randomized, single-blind, controlled trial, Level I.
Collapse
Affiliation(s)
- M G M Schotanus
- Department of Orthopaedic Surgery, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands.
| | - P Pilot
- Department of Orthopaedic Surgery, Reinier de Graafweg Hospital, Delft, The Netherlands
| | - B L Kaptein
- Department of Orthopaedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
| | - W F Draijer
- Department of Orthopaedic Surgery, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands
| | - P B J Tilman
- Department of Orthopaedic Surgery, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands
| | - R Vos
- Department of Methodology and Statistics, Maastricht University Medical Center, Maastricht, The Netherlands
| | - N P Kort
- Department of Orthopaedic Surgery, Zuyderland Medical Centre, Sittard-Geleen, The Netherlands
| |
Collapse
|
5
|
No differences between fixed- and mobile-bearing total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2017; 25:1757-1777. [PMID: 27324479 DOI: 10.1007/s00167-016-4195-x] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Accepted: 06/07/2016] [Indexed: 12/20/2022]
Abstract
PURPOSE For years, numerous studies have been performed to determine whether mobile-bearing total knee arthroplasty (MB-TKA) or fixed-bearing total knee arthroplasty (FB-TKA) is the preferential design in total knee arthroplasty. Reviews and meta-analyses on this subject have focused on a relatively small number of randomised controlled trials, possibly missing important results of smaller studies. The goal of this review was to provide a comprehensive overview of all literature comparing MB-TKA and FB-TKA in the treatment of osteoarthritis of the knee. METHODS An extensive literature search was performed in the PubMed database. All studies that compared MB-TKA with FB-TKA and looked at one of four theorised advantages (insert wear, signs of loosening, survival rate of the prosthesis and clinical outcome) were included. RESULTS The initial search yielded 258 articles, of which 127 were included after the first screening. The included studies consisted of 9 meta-analyses, 3 systematic reviews, 48 RCT's, 44 comparative studies, 10 reviews and 13 studies that examined patients who received bilateral TKA (one MB-TKA and one FB-TKA). Combining the results of all studies showed that almost all studies found no difference between MB-TKA and FB-TKA. CONCLUSIONS Even when examining all different types of studies on MB-TKA and FB-TKA, the results of this review showed no difference in insert wear, risk of loosening, survivorship or clinical outcome. In daily practice, the choice between MB-TKA and FB-TKA should be based on the experience and judgment of the surgeon, since no clear differences are observed in the scientific literature. LEVEL OF EVIDENCE III.
Collapse
|
6
|
Nguyen LCL, Lehil MS, Bozic KJ. Trends in total knee arthroplasty implant utilization. J Arthroplasty 2015; 30:739-42. [PMID: 25613663 DOI: 10.1016/j.arth.2014.12.009] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Revised: 12/01/2014] [Accepted: 12/04/2014] [Indexed: 02/01/2023] Open
Abstract
The incidence of total knee arthroplasty (TKA) has increased alongside our knowledge of knee physiology, kinematics, and technology resulting in an evolution of TKA implants. This study examines the trends in TKA implant utilization. Data was extracted from The Orthopedic Research Network to evaluate trends in level of constraint, fixed vs. mobile bearing, fixation, and type of polyethylene in primary TKAs. In 2012, 88% used cemented femoral and tibial implants, and 96% involved patellar resurfacing. 38% of implants were cruciate retaining, 53% posterior stabilized or condylar stabilized, 3% constrained. 91% were fixed-bearing, 7% mobile-bearing. 52% of tibial inserts were HXLPE. TKA implant trends demonstrate a preference for cemented femoral and tibial components, patellar resurfacing, fixed-bearing constructs, metal-backed tibial components, patellar resurfacing, and increased usage of HXLPE liners.
Collapse
Affiliation(s)
- Long-Co L Nguyen
- School of Medicine, University of California, San Francisco, San Francisco, California
| | - Mandeep S Lehil
- School of Medicine, University of California, San Francisco, San Francisco, California
| | - Kevin J Bozic
- Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, California; Philip. R Lee Institute for Health Policy Studies, University of California, San Francisco, San Francisco, California
| |
Collapse
|
7
|
No difference in clinical and radiologic outcomes after total knee arthroplasty with a new ultra-congruent mobile bearing system and rotating platform mobile bearing systems after minimum 5-year follow-up. J Arthroplasty 2015; 30:379-83. [PMID: 25449590 DOI: 10.1016/j.arth.2014.09.025] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 09/10/2014] [Accepted: 09/25/2014] [Indexed: 02/01/2023] Open
Abstract
We retrospectively compared the clinical and radiographic results between 76 primary total knee arthroplasties (TKAs) using the e.motion Ultra-Congruent prosthesis and 155 primary TKAs using the Low Contact Stress rotating platform. All patients had a minimum 5-year follow-up. Range of motion, Hospital for Special Surgery score, Knee Society Knee Score and Knee Society Functional Score significantly increased in both groups postoperatively, but there was no significant difference between the two groups. The mechanical femorotibial angle improved in both groups postoperatively. Coronal and sagittal component angles were well maintained at the final follow-up. This study demonstrates that a new mobile-bearing prosthesis, designed to be highly congruent with a rotating bearing, could be considered with theoretical advantages and comparable outcomes of established mobile-bearing prostheses.
Collapse
|
8
|
Hofstede SN, Nouta KA, Jacobs W, van Hooff ML, Wymenga AB, Pijls BG, Nelissen RGHH, Marang-van de Mheen PJ. Mobile bearing vs fixed bearing prostheses for posterior cruciate retaining total knee arthroplasty for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis. Cochrane Database Syst Rev 2015; 2015:CD003130. [PMID: 25650566 PMCID: PMC10960232 DOI: 10.1002/14651858.cd003130.pub3] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND It is unclear whether there are differences in benefits and harms between mobile and fixed prostheses for total knee arthroplasty (TKA). The previous Cochrane review published in 2004 included two articles. Many more trials have been performed since then; therefore an update is needed. OBJECTIVES To assess the benefits and harms of mobile bearing compared with fixed bearing cruciate retaining total knee arthroplasty for functional and clinical outcomes in patients with osteoarthritis (OA) or rheumatoid arthritis (RA). SEARCH METHODS We searched The Cochrane Library, PubMed, EMBASE, CINAHL and Web of Science up to 27 February 2014, and the trial registers ClinicalTrials.gov, Multiregister, Current Controlled Trials and the World Health Organization (WHO) International Clinical Trials Registry Platform for data from unpublished trials, up to 11 February 2014. We also screened the reference lists of selected articles. SELECTION CRITERIA We selected randomised controlled trials comparing mobile bearing with fixed bearing prostheses in cruciate retaining TKA among patients with osteoarthritis or rheumatoid arthritis, using functional or clinical outcome measures and follow-up of at least six months. DATA COLLECTION AND ANALYSIS We used standard methodological procedures as expected by The Cochrane Collaboration. MAIN RESULTS We found 19 studies with 1641 participants (1616 with OA (98.5%) and 25 with RA (1.5%)) and 2247 knees. Seventeen new studies were included in this update.Quality of the evidence ranged from moderate (knee pain) to low (other outcomes). Most studies had unclear risk of bias for allocation concealment, blinding of participants and personnel, blinding of outcome assessment and selective reporting, and high risk of bias for incomplete outcome data and other bias. Knee painWe calculated the standardised mean difference (SMD) for pain, using the Knee Society Score (KSS) and visual analogue scale (VAS) in 11 studies (58%) and 1531 knees (68%). No statistically significant differences between groups were reported (SMD 0.09, 95% confidence interval (CI) -0.03 to 0.22, P value 0.15). This represents an absolute risk difference of 2.4% points higher (95% CI 0.8% lower to 5.9% higher) on the KSS pain scale and a relative percent change of 0.22% (95% CI 0.07% lower to 0.53% higher). The results were homogeneous. Clinical and functional scores The KSS clinical score did not differ statistically significantly between groups (14 studies (74%) and 1845 knees (82%)) with a mean difference (MD) of -1.06 points (95% CI -2.87 to 0.74, P value 0.25) and heterogeneous results. KSS function was reported in 14 studies (74%) with 1845 knees (82%) as an MD of -0.10 point (95% CI -1.93 to 1.73, P value 0.91) and homogeneous results. In two studies (11%), the KSS total score was favourable for mobile bearing (159 vs 132 for fixed bearing), with MD of -26.52 points (95% CI -45.03 to -8.01, P value 0.005), but with a wide 95% confidence interval indicating uncertainty about the estimate.Other reported scoring systems did not show statistically significant differences: Hospital for Special Surgery (HSS) score (seven studies (37%) in 1021 knees (45%)) with an MD of -1.36 (95% CI -4.18 to 1.46, P value 0.35); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score (two studies (11%), 167 knees (7%)) with an MD of -4.46 (95% CI -16.26 to 7.34, P value 0.46); and Oxford total (five studies (26%), 647 knees (29%) with an MD of -0.25 (95% CI -1.41 to 0.91, P value 0.67). Health-related quality of lifeThree studies (16%) with 498 knees (22%) reported on health-related quality of life, and no statistically significant differences were noted between the mobile bearing and fixed bearing groups. The Short Form (SF)-12 Physical Component Summary had an MD of -1.96 (95% CI -4.55 to 0.63, P value 0.14) and heterogeneous results. Revision surgeryTwenty seven revisions (1.3%) were performed in 17 studies (89%) with 2065 knees (92%). In all, 13 knees were revised in the fixed bearing group and 14 knees in the mobile bearing group. No statistically significant differences were found (risk difference 0.00, 95% CI -0.01 to 0.01, P value 0.58), and homogeneous results were reported. MortalityIn seven out of 19 studies, 13 participants (37%) died. Two of these participants had undergone bilateral surgery, and for seven participants, it was unclear which prosthesis they had received; therefore they were excluded from the analyses. Thus our analysis included four out of 191 participants (2.1%) who had died: one in the fixed bearing group and three in the mobile bearing group. No statistically significant differences were found. The risk difference was -0.02 (95% CI -0.06 to 0.03, P value 0.49) and results were homogeneous. Reoperation ratesThirty reoperations were performed in 17 studies (89%) with 2065 knees (92%): 18 knees in the fixed bearing group (of the 1031 knees) and 12 knees in the mobile group (of the 1034 knees). No statistically significant differences were found. The risk difference was -0.01 (95% CI -0.01 to 0.01, P value 0.99) with homogeneous results. Other serious adverse eventsSixteen studies (84%) reported nine other serious adverse events in 1735 knees (77%): four in the fixed bearing group (of the 862 knees) and five in the mobile bearing group (of the 873 knees). No statistically significant differences were found (risk difference 0.00, 95% CI -0.01 to 0.01, P value 0.88), and results were homogeneous. AUTHORS' CONCLUSIONS Moderate- to low-quality evidence suggests that mobile bearing prostheses may have similar effects on knee pain, clinical and functional scores, health-related quality of life, revision surgery, mortality, reoperation rate and other serious adverse events compared with fixed bearing prostheses in posterior cruciate retaining TKA. Therefore we cannot draw firm conclusions. Most (98.5%) participants had OA, so the findings primarily reflect results reported in participants with OA. Future studies should report in greater detail outcomes such as those presented in this systematic review, with sufficient follow-up time to allow gathering of high-quality evidence and to inform clinical practice. Large registry-based studies may have added value, but they are subject to treatment-by-indication bias. Therefore, this systematic review of RCTs can be viewed as the best available evidence.
Collapse
Key Words
- humans
- knee prosthesis
- arthritis, rheumatoid
- arthritis, rheumatoid/surgery
- arthroplasty, replacement, knee
- arthroplasty, replacement, knee/adverse effects
- arthroplasty, replacement, knee/instrumentation
- arthroplasty, replacement, knee/mortality
- bias
- health status
- knee joint
- osteoarthritis, knee
- osteoarthritis, knee/surgery
- prosthesis design
- prosthesis design/methods
- quality of life
- randomized controlled trials as topic
- range of motion, articular
- reoperation
- reoperation/statistics & numerical data
Collapse
Affiliation(s)
- Stefanie N Hofstede
- Department of Medical Decision Making, Leiden University Medical Center, Postzone J10-s, room J10-88, P.O. Box 9600, Leiden, Netherlands, 2300 RC.
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Dynamic finite element analysis of mobile bearing type knee prosthesis under deep flexional motion. ScientificWorldJournal 2014; 2014:586921. [PMID: 25133247 PMCID: PMC4124825 DOI: 10.1155/2014/586921] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2014] [Accepted: 05/22/2014] [Indexed: 11/17/2022] Open
Abstract
The primary objective of this study is to distinguish between mobile bearing and fixed bearing posterior stabilized knee prostheses in the mechanics performance using the finite element simulation. Quantifying the relative mechanics attributes and survivorship between the mobile bearing and the fixed bearing prosthesis remains in investigation among researchers. In the present study, 3-dimensional computational model of a clinically used mobile bearing PS type knee prosthesis was utilized to develop a finite element and dynamic simulation model. Combination of displacement and force driven knee motion was adapted to simulate a flexion motion from 0° to 135° with neutral, 10°, and 20° internal tibial rotation to represent deep knee bending. Introduction of the secondary moving articulation in the mobile bearing knee prosthesis has been found to maintain relatively low shear stress during deep knee motion with tibial rotation.
Collapse
|
10
|
Kremers HM, Sierra RJ, Schleck CD, Berry DJ, Cabanela ME, Hanssen AD, Pagnano MW, Trousdale RT, Lewallen DG. Comparative Survivorship of Different Tibial Designs in Primary Total Knee Arthroplasty. J Bone Joint Surg Am 2014; 96:e121. [PMID: 25031383 DOI: 10.2106/jbjs.m.00820] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Few registry-based studies in the United States have compared the survivorship of different knee implant designs in total knee arthroplasty. The purpose of this study was to compare differences in survivorship of commonly used tibial implant designs in primary total knee arthroplasty. METHODS A total of 16,584 primary total knee arthroplasties in 11,992 patients were performed at a single institution from 1985 to 2005. Patients were prospectively followed at regular intervals to ascertain details of subsequent revisions. Overall revision rates and revisions for aseptic loosening, wear, and osteolysis were compared across twenty-two tibial implant designs using Cox proportional hazards regression models adjusting for age, sex, calendar year, and body mass index. RESULTS In comparison with metal-backed modular implants, all-polyethylene tibial components had a significantly lower risk of revision (hazard ratio, 0.3; 95% confidence intervals: 0.2, 0.5 [p < 0.0001]). The risk reduction with all-polyethylene tibial components was not affected by age, sex, or body mass index. With metal-backed modular tibial designs, cruciate-retaining knees performed better than the posterior-stabilized knees (p = 0.002), but this finding was limited to one specific metal-backed modular tibial component, the Press Fit Condylar design. With all-polyethylene tibial components, there was no survivorship difference between cruciate-retaining and posterior-stabilized designs. CONCLUSIONS All-polyethylene tibial components were associated with better outcomes than metal-backed modular components. Cruciate-retaining and posterior-stabilized designs performed equally well, except with the Press Fit Condylar design. Obese patients may have superior results with all-polyethylene and posterior-stabilized components. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Hilal Maradit Kremers
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Rafael J Sierra
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Cathy D Schleck
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Daniel J Berry
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Miguel E Cabanela
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Arlen D Hanssen
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Mark W Pagnano
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - Robert T Trousdale
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| | - David G Lewallen
- Departments of Health Sciences Research (H.M.K. and C.D.S.) and Orthopedic Surgery (R.J.S., D.J.B., M.E.C., A.D.H., M.W.P., R.T.T., and D.G.L.), Mayo Clinic, 200 First Street SW, Rochester, MN 55905. E-mail address for H.M. Kremers:
| |
Collapse
|
11
|
Rotating-platform TKA no different from fixed-bearing TKA regarding survivorship or performance: a meta-analysis. Clin Orthop Relat Res 2014; 472:2185-93. [PMID: 24590838 PMCID: PMC4048397 DOI: 10.1007/s11999-014-3539-4] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2013] [Accepted: 02/18/2014] [Indexed: 01/31/2023]
Abstract
BACKGROUND Mobile bearings have been compared with fixed bearings used in TKA. However, rotating platforms, a specific type of mobile bearing, have not been compared with fixed-bearings using meta-analysis. QUESTIONS/PURPOSES We asked whether the performance of a rotating-platform bearing is superior to, comparable to, or worse than a fixed bearing. Four areas were investigated: clinical performance, component alignment, adverse event rates, and revision rates. METHODS Searches of Medline, EMBASE, Google Scholar, and the Cochrane databases, combined with reference lists from published meta-analyses and systematic reviews of mobile-bearing versus fixed-bearing prostheses used in TKAs, provided 17 nonlanguage-restricted studies consisting of 1910 TKAs (966 rotating platform versus 944 fixed bearing). Random-effect modeling was used for all meta-analyses, thereby mitigating possible effects of heterogeneity among studies. All meta-analyses were examined for publication bias using funnel plots; publication bias was not detected for any meta-analysis. RESULTS There were no statistically or clinically significant differences in clinical performance (clinical scores, ROM, and radiographic evaluation), component alignment, revision rates, or adverse event rates except for tibial component alignment in the AP plane, which favored TKA with fixed-bearings (p = 0.020; standardized mean difference, 0.229; 95% CI, 0.035-0.422), but the effect size was small enough that it was not considered clinically important. CONCLUSIONS Based on our findings, which agree substantially with those of prior systematic reviews of TKAs with mobile-bearing versus fixed-bearing prostheses, there is no compelling case for either rotating-platform or fixed-bearing implant design in terms of clinical performance, component alignment, adverse event frequencies, or survivorship. This dataset, which was limited to a maximum 6 years followup, is insufficient to address questions related to wear or late revisions. We therefore suggest that implant choice should be made on the basis of other factors, perhaps including cost or surgeon experience.
Collapse
|
12
|
Preoperative flexion does not influence postoperative flexion after rotating-platform total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014; 22:1644-8. [PMID: 23314187 DOI: 10.1007/s00167-013-2378-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2012] [Accepted: 01/04/2013] [Indexed: 10/27/2022]
Abstract
PURPOSE Preoperative range of motion (ROM) has been regarded as one of the most important factors in predicting postoperative ROM following total knee arthroplasty (TKA). Mobile-bearing TKA designs have been suggested to possibly improve the knee kinematics compared to fixed-bearing designs. The purpose of this study was to examine the difference in postoperative flexion as a function of preoperative flexion in a consecutive series of TKAs done using a posterior-stabilized rotating-platform prosthesis. METHODS ROM was assessed in 153 consecutive TKAs done using a rotating-platform posterior cruciate-substituting design. Patients were divided into two groups based on their preoperative ROM (Group 1 < 95°, Group 2 > 95°). The Knee Society Score (KSS) and ROM were assessed preoperatively, 3 months and 12 months postoperatively. RESULTS There was no difference in flexion 12 months after surgery between groups (mean 120° and 123°, respectively. n.s.). After 3 month follow-up, no increase in ROM was experienced by either group. Patients in Group 1 experienced significantly greater increases in both ROM (p < 0.001) and KSS (p < 0.05). There was no difference in the KSS at 12 months after surgery between groups. CONCLUSION In this series of patients undergoing TKA with a rotating-platform prosthesis, the preoperative ROM was not predictive of the postoperative ROM. Patients with stiff knees preoperatively may benefit from a mobile-bearing design prosthesis.
Collapse
|
13
|
SOLARINO GIUSEPPE, SPINARELLI ANTONIO, CARROZZO MASSIMILIANO, PIAZZOLLA ANDREA, VICENTI GIOVANNI, MORETTI BIAGIO. Long-term outcome of low contact stress total knee arthroplasty with different mobile bearing designs. JOINTS 2014; 2:109-114. [PMID: 25606553 PMCID: PMC4295681 DOI: 10.11138/jts/2014.2.3.109] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE to evaluate the differences in clinical outcome and survivorship of three different mobile bearings for total knee arthroplasty. METHODS a retrospective study was conducted in 60 patients (53 females, 7 males, mean age: 68 years and 5 months) each submitted to total knee replacement using one of the three different mobile bearings of the LCS system (Depuy Johnson & Johnson, Warsaw, IN). The diagnosis was knee osteoarthritis in 57 cases and rheumatoid arthritis in three cases. Three different groups of 20 cases each were identified: total knee arthroplasties with mobile menisci (group 1); total knee arthroplasties with the rotating platform (group 2); and total knee arthroplasties with the anteroposterior glide platform (group 3). As regards the component fixation, 33 implants were cementless, three were cemented, and in 24 only the tibial component was cemented. The patella was not replaced. RESULTS although the duration of follow-up differed between the three groups, the clinical and radiological results at final follow-up showed no revision of femoral and/or tibial components for mechanical or septic reasons, and no signs of impending failure. One meniscal bearing, showing polyethylene wear after 17 years, was successfully replaced. CONCLUSIONS the present retrospective study confirmed the long-term effectiveness of knee implants with mobile bearings, in which the congruity of the surfaces makes it possible to overcome the problem of high contact stresses that may result in polyethylene wear and osteolysis; at the same time, these implants eliminate constraint forces thereby reducing the risk of mechanical loosening. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- GIUSEPPE SOLARINO
- Orthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari “Aldo Moro”, Bari, Italy
| | - ANTONIO SPINARELLI
- Orthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari “Aldo Moro”, Bari, Italy
| | - MASSIMILIANO CARROZZO
- Orthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari “Aldo Moro”, Bari, Italy
| | - ANDREA PIAZZOLLA
- Orthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari “Aldo Moro”, Bari, Italy
| | - GIOVANNI VICENTI
- Orthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari “Aldo Moro”, Bari, Italy
| | - BIAGIO MORETTI
- Orthopaedic Section, Department of Basic Medical Sciences, Neurosciences and Sensory Organs, University of Bari “Aldo Moro”, Bari, Italy
| |
Collapse
|
14
|
Mobile bearing or fixed bearing? A meta-analysis of outcomes comparing mobile bearing and fixed bearing bilateral total knee replacements. Knee 2014; 21:374-81. [PMID: 24380804 DOI: 10.1016/j.knee.2013.10.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 10/13/2013] [Accepted: 10/16/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND To compare outcomes between mobile-bearing (MB) and fixed-bearing (FB) in bilateral total knee replacements. METHODS The MEDLINE, EMBASE and Cochrane Library databases were searched. Randomized controlled trials of bilateral total knee arthroplasty with one of each design implanted were identified. Weighted mean differences (WMDs) and pooled risk ratios (RRs) were calculated using fixed- or random-effects models. RESULTS Twelve studies were identified with a total of 807 patients and 1614 knees. All RCTs were of high quality with a low risk of bias. No statistical difference was found between MB and FB at 2- to 5-year follow-up in terms of America Knee Society score (WMD: -1.29, 95% CI: -5.65 to 3.06), pain score (WMD: -3.26, 95% CI: -10.45 to 3.93), range of motion (WMD: -4.16, 95% CI: -9.97 to 1.66), reoperation (RR: 1.00, 95% CI: 0.28 to 3.60), and radiolucent lines (RR: 1.51, 95% CI: 0.70 to 3.24). The results were similar at 1-, 5- to 8-, or >8-year follow-up. Patient's satisfaction (RR: 0.85, 95% CI: 0.54 to 1.34), and complication (≤2-year, RR: 0.55, 95% CI: 0.29 to 1.04; >2-year, RR: 1.0, 95% CI=0.73 to 1.38) also showed no difference between two groups. CONCLUSIONS Based on this meta-analysis we are unable to detect the superiority of MB as compared to FB. More randomized trials with a larger sample size and longer follow-up are needed to evaluate these two kinds of prosthesis. LEVEL OF EVIDENCE Therapeutic Level II.
Collapse
|
15
|
Urwin SG, Kader DF, Caplan N, St Clair Gibson A, Stewart S. Gait analysis of fixed bearing and mobile bearing total knee prostheses during walking: do mobile bearings offer functional advantages? Knee 2014; 21:391-5. [PMID: 24238651 DOI: 10.1016/j.knee.2013.10.007] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2013] [Revised: 10/02/2013] [Accepted: 10/17/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND Limited previous findings have detailed biomechanical advantages following implantation with mobile bearing (MB) prostheses after total knee replacement (TKR) surgery during walking. The aim of this study was to compare three dimensional spatiotemporal, kinematic, and kinetic parameters during walking to examine whether MBs offer functional advantages over fixed bearing (FB) designs. METHODS Sixteen patients undergoing primary unilateral TKR surgery were randomised to receive either a FB (n=8) or MB (n=8) total knee prosthesis. Eight age and gender matched controls underwent the same protocol on one occasion. A 12 camera Vicon system integrated with four force plates was used. Patients were tested pre-surgery and nine months post-surgery. RESULTS No significant differences between FB and MB groups were found at any time point in the spatiotemporal parameters. The MB group was found to have a significantly reduced frontal plane knee range of motion (ROM) at pre-surgery than the FB group (FB=14.92±4.02°; MB=8.87±4.82°), with the difference not observed post-surgery. No further significant kinematic or kinetic differences were observed between FB and MB groups. Fixed bearing and MB groups both displayed spatiotemporal, kinematic, and kinetic differences when compared to controls. Fixed bearing and MB groups differed from controls in six and five parameters at nine months post-surgery, respectively. CONCLUSIONS No functional advantages were found in knees implanted with MB prostheses during walking, with both groups indicative of similar differences when compared to normal knee biomechanics following prosthesis implantation. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Samuel G Urwin
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK.
| | - Deiary F Kader
- Orthopaedics and Trauma, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| | - Nick Caplan
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| | - Alan St Clair Gibson
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| | - Su Stewart
- Department of Sport, Exercise, and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK; Orthopaedic and Sports Injury Research Group, Queen Elizabeth Hospital, Sheriff Hill, Gateshead, UK
| |
Collapse
|
16
|
Zingde SM, Leszko F, Sharma A, Mahfouz MR, Komistek RD, Dennis DA. In vivo determination of cam-post engagement in fixed and mobile-bearing TKA. Clin Orthop Relat Res 2014; 472:254-62. [PMID: 23990448 PMCID: PMC3889432 DOI: 10.1007/s11999-013-3257-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Kinematics vary, sometimes in important ways, among the different types of total knee arthroplasty (TKA) designs, yet differences between the in vivo mechanisms of cam-post engagement in rotating-platform posterior-stabilized (PS) TKA, bicruciate-stabilized TKA, and fixed-bearing PS TKA designs remain largely uncharacterized. QUESTIONS/PURPOSES The objective of this study was to determine the cam-post mechanism interaction for subjects implanted with three different TKA designs. METHODS In vivo, analysis was conducted for patients implanted with nine rotating-platform PS TKAs, five knees with a fixed-bearing PS TKA, and 10 knees with a bicruciate-stabilized TKA while performing a deep knee bend. Three-dimensional kinematics of the implant components were determined by analysis of fluoroscopic images during flexion. The distances between the interacting surfaces were measured throughout flexion and instances and locations of contact were identified. RESULTS Seven of the 10 bicruciate-stabilized knees analyzed had the femoral component engaged with the anterior aspect of the tibial post at full extension. Posterior cam-post engagement occurred at 34° for the bicruciate-stabilized (range, 17°-68°), 93° for the fixed-bearing PS (range, 88°-100°), and at 97° (range, 90°-104°) for rotating-platform PS TKA. In bicruciate-stabilized and fixed-bearing PS knees, the contact initially occurred on the medial aspect of the posterior surface of the tibial post and then moved centrally and superiorly with increasing flexion. For rotating-platform PS TKA, it was located centrally on the posterior surface of the post at all times. CONCLUSIONS This study suggests that mobility of the polyethylene might play an important role in ensuring central cam-post interaction in PS TKA. The polyethylene insert rotates axially in accordance with the rotating femur, maintaining central cam-post contact. This phenomenon was not observed in the fixed-bearing PS TKAs analyzed in this study. CLINICAL RELEVANCE We speculate that this centralized symmetrical contact between the cam and posterior surface of the post could be beneficial clinically in terms of reducing wear of the posterior surface and particularly at the medial extremes of it.
Collapse
Affiliation(s)
- Sumesh M. Zingde
- Center for Musculoskeletal Research, University of Tennessee, 301 Perkins Hall, Knoxville, TN 37996 USA
| | | | - Adrija Sharma
- Center for Musculoskeletal Research, University of Tennessee, 301 Perkins Hall, Knoxville, TN 37996 USA
| | - Mohamed R. Mahfouz
- Center for Musculoskeletal Research, University of Tennessee, 301 Perkins Hall, Knoxville, TN 37996 USA
| | - Richard D. Komistek
- Center for Musculoskeletal Research, University of Tennessee, 301 Perkins Hall, Knoxville, TN 37996 USA
| | - Douglas A. Dennis
- Colorado Joint Replacement, Denver, CO USA ,Department of Biomedical Engineering, University of Tennessee, Knoxville, TN USA ,The University of Colorado Health Sciences Center, Denver, CO USA ,Rocky Mountain Musculoskeletal Research Laboratory, Denver, CO USA
| |
Collapse
|
17
|
Ferguson KB, Bailey O, Anthony I, James PJ, Stother IG, M J G B. A prospective randomised study comparing rotating platform and fixed bearing total knee arthroplasty in a cruciate substituting design--outcomes at two year follow-up. Knee 2014; 21:151-5. [PMID: 24145068 DOI: 10.1016/j.knee.2013.09.007] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2013] [Revised: 09/22/2013] [Accepted: 09/25/2013] [Indexed: 02/02/2023]
Abstract
BACKGROUND Fixed bearing (FB) total knee replacement is a well established technique against which new techniques must be compared. Mobile bearing (MB) prostheses, in theory, reduce polyethylene wear but the literature is yet to provide evidence that they are superior in terms of function or long-term survivorship. In addition there has been no comparison of patella resurfacing on the outcome of either design. The aims of this randomised prospective study were firstly to determine whether a mobile bearing prosthesis produced better clinical outcome and range of motion at two year follow-up and secondly to assess the effect of patella resurfacing on the outcomes of both types of bearing design. METHODS Three hundred fifty-two patients were randomised into receiving either a PFC Sigma© cruciate sacrificing total knee arthroplasty either with a mobile bearing or a fixed bearing, with a sub-randomisation to either patella resurfacing or patella retention. All patients participated with standard clinical outcome measures and had their range of motion measured both pre-operatively and at follow-up. RESULTS The mobile bearing TKR design had no impact on range of motion; Oxford Knee Score and American Knee Society knee and function scores when compared to its fixed bearing equivalent. CONCLUSIONS At two year follow-up there was no difference between the PFC Sigma© fixed and mobile bearing designs. With no clinical difference between the cohorts, we cannot recommend one design over the other. Long term benefits, particularly with regards to polyethylene wear, may yet be demonstrated. Level of evidence--1B.
Collapse
Affiliation(s)
- K B Ferguson
- Department of Orthopaedics and Trauma, Glasgow Royal Infirmary, United Kingdom
| | - O Bailey
- Department of Orthopaedics and Trauma, Glasgow Royal Infirmary, United Kingdom
| | - I Anthony
- Department of Orthopaedics and Trauma, Glasgow Royal Infirmary, United Kingdom
| | - P J James
- Department of Orthopaedics and Trauma, Nottingham City Hospital, United Kingdom
| | - I G Stother
- Department of Orthopaedics and Trauma, Glasgow Royal Infirmary, United Kingdom
| | - Blyth M J G
- Department of Orthopaedics and Trauma, Glasgow Royal Infirmary, United Kingdom.
| |
Collapse
|
18
|
Magin MN. [Spin out - an avoidable complication in total knee replacement]. DER ORTHOPADE 2013; 43:175-9. [PMID: 24154659 DOI: 10.1007/s00132-013-2202-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Spin out of a rotating polyethylene (PE) platform after total knee replacement leads to rotation of the bearing compared to the fixed metal components of the prosthesis at the femur and tibia of approximately 90°. This complication occurs only in prosthesis designs which do not have a rotation limitation. Identification of this complication and its management are described exemplified by two cases. Strategies to avoid spin out are discussed. The most promising way is to avoid using prosthesis designs in which spin out can occur.
Collapse
Affiliation(s)
- M N Magin
- Spezialpraxis für Orthopädie, Bahnhofsweg 10, 82008, Unterhaching/München, Deutschland,
| |
Collapse
|
19
|
Daniilidis K, Höll S, Gosheger G, Dieckmann R, Martinelli N, Ostermeier S, Tibesku CO. Femoro-tibial kinematics after TKA in fixed- and mobile-bearing knees in the sagittal plane. Knee Surg Sports Traumatol Arthrosc 2013; 21:2392-7. [PMID: 22476524 DOI: 10.1007/s00167-012-1986-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Accepted: 03/20/2012] [Indexed: 11/29/2022]
Abstract
PURPOSE Lack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile-bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed- and mobile-bearing TKA in comparison with the natural knee joint. METHODS Seven knee joints of human cadaver material were used in a laboratory experiment. Fixed- and mobile-bearing inlays were tested in sequences under isokinetic extension in so-called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio-femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control. RESULTS The results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z-axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile-bearing" and "fixed-bearing" prostheses. CONCLUSION Results of this study cannot prove functional advantages of mobile-bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.
Collapse
Affiliation(s)
- Kiriakos Daniilidis
- Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Strasse 1-7, Hannover, Germany,
| | | | | | | | | | | | | |
Collapse
|
20
|
Chavoix JB. Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion ((®)) UC-TKA. Open Orthop J 2013; 7:152-7. [PMID: 23730378 PMCID: PMC3664449 DOI: 10.2174/1874325001307010152] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Revised: 04/03/2013] [Accepted: 04/04/2013] [Indexed: 11/22/2022] Open
Abstract
Background: Mobile bearing TKA prostheses were designed to minimize polyethylene wear by increasing implant conformity and reducing stresses between the articulating prosthesis components. It is the purpose of this study to assess the mid-term functionality and clinical outcome associated with a highly congruent mobile platform design, the e.motion® UC total knee prosthesis. Material and Methods: Functional and clinical outcomes were assessed after an average of 5.6 years (5.1 – 6.0 years) after total knee arthroplasty in 28 patients (24 women), aged 77.8±7.5 years. The Knee injury and Osteoarthritis Outcome Score (KOOS) was assessed. Secondary outcomes included the Knee Society Score (KSS), radiological evaluation of radiolucent lines and recording of adverse events. Results: The average KOOS subscore for the activities of daily life was 77.8 points after 5.6 years. Both the clinical and functional KSS improved at 2.4 and 5.6 years. Two patients showed radiolucent lines at 5.6 years. Adverse events over 5.6 years included 3 subluxations, 1 tilting and 1 misalignment of the patella. None of the prostheses were revised. Conclusion: This pilot study shows promising outcomes for the e.motion® UC prosthesis. In the small sample, the implant performed comparably to the LCS prosthesis (the gold standard). There were no loosenings or revisions observed at 5.6 years.
Collapse
|
21
|
Reichen A, Rüegsegger M. Five-year results of total knee arthroplasty with the Vario Knee System: a prospective analysis. Knee 2012; 19:324-8. [PMID: 21820314 DOI: 10.1016/j.knee.2011.06.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2010] [Revised: 06/21/2011] [Accepted: 06/24/2011] [Indexed: 02/02/2023]
Abstract
There have been no published reports detailing the clinical performance of the Vario Knee System (VKS) total knee arthroplasty (TKA) since its introduction in 2001. The current study was therefore undertaken to provide 5-year clinical and radiographic follow-up data for this implant. Over a 24-month period, 146 VKS TKAs were performed in 131 patients (mean age, 69 years). Prospective data and radiographs were obtained at 3 months, 1 year, and 5 years after surgery. Surgeons employed an anteromedial approach in which the cruciate was retained. The fixation method was hybrid (cemented tibia, uncemented femur) in 70% of patients, uncemented in 23%, and cemented in 7%. At 5 years, 106 patients (118 knees) were alive. Six patients (six knees) were lost to follow-up. Three knees (three patients) were revised. Five-year survival was 97.4% (95% confidence interval [CI]: 92.8-99.5) with an endpoint of revision for any reason and 99.0% (95% CI: 97.5-100) with an endpoint of revision for aseptic failure. Using the worst-case scenario, in which all six of these patients were considered as failures, survival was 91.4% (95% CI: 83.4-96.0). The mean preoperative knee and function scores improved from 37.5 and 62.1, respectively, to 90.6 and 97.4, respectively, 5 years after surgery. Radiographic loosening of either component was not observed in any of the 100 radiographs obtained. In conclusion, good clinical outcomes were observed after 5 years with the VKS TKA. Additional follow-up studies will be needed to ascertain whether this performance is maintained in the long term.
Collapse
Affiliation(s)
- Alfred Reichen
- Klinik Stephanshorn, Brauerstrasse 95, 9016 St. Gallen, Switzerland.
| | | |
Collapse
|
22
|
Jawed A, Kumar V, Malhotra R, Yadav CS, Bhan S. A comparative analysis between fixed bearing total knee arthroplasty (PFC Sigma) and rotating platform total knee arthroplasty (PFC-RP) with minimum 3-year follow-up. Arch Orthop Trauma Surg 2012; 132:875-81. [PMID: 22526193 DOI: 10.1007/s00402-012-1482-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2011] [Indexed: 11/29/2022]
Abstract
BACKGROUND Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study. METHODS A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared. RESULTS At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up. CONCLUSIONS Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.
Collapse
Affiliation(s)
- Akram Jawed
- Department of Orthopaedics, All India Institute of Medical Sciences, Room No. 5019, New Delhi 110029, India.
| | | | | | | | | |
Collapse
|
23
|
Jolles BM, Grzesiak A, Eudier A, Dejnabadi H, Voracek C, Pichonnaz C, Aminian K, Martin E. A randomised controlled clinical trial and gait analysis of fixed- and mobile-bearing total knee replacements with a five-year follow-up. ACTA ACUST UNITED AC 2012; 94:648-55. [DOI: 10.1302/0301-620x.94b5.27598] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years’ follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years). Improvements in most gait parameters at five years’ follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.
Collapse
Affiliation(s)
- B. M. Jolles
- CHUV and University of Lausanne – Site
Hôpital Orthopédique, 4 Avenue Pierre Decker, CH-1011
Lausanne, Switzerland
| | - A. Grzesiak
- CHUV and University of Lausanne – Site
Hôpital Orthopédique, 4 Avenue Pierre Decker, CH-1011
Lausanne, Switzerland
| | - A. Eudier
- CHUV and University of Lausanne – Site
Hôpital Orthopédique, 4 Avenue Pierre Decker, CH-1011
Lausanne, Switzerland
| | - H. Dejnabadi
- École Polytechnique Fédérale de Lausanne
– CBT - LMAM, CH-1015 Lausanne, Switzerland
| | - C. Voracek
- CHUV and University of Lausanne – Site
Hôpital Orthopédique, 4 Avenue Pierre Decker, CH-1011
Lausanne, Switzerland
| | - C. Pichonnaz
- CHUV and University of Lausanne – Site
Hôpital Orthopédique, 4 Avenue Pierre Decker, CH-1011
Lausanne, Switzerland
| | - K. Aminian
- École Polytechnique Fédérale de Lausanne
– CBT - LMAM, CH-1015 Lausanne, Switzerland
| | - E. Martin
- CHUV and University of Lausanne – Department
of Geriatrics and Geriatric Rehabilitation, Hôpital
de Sylvana, CH-1011 Lausanne, Switzerland
| |
Collapse
|
24
|
Wolterbeek N, Garling EH, Mertens BJ, Nelissen RGHH, Valstar ER. Kinematics and early migration in single-radius mobile- and fixed-bearing total knee prostheses. Clin Biomech (Bristol, Avon) 2012; 27:398-402. [PMID: 22055272 DOI: 10.1016/j.clinbiomech.2011.10.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2011] [Revised: 10/15/2011] [Accepted: 10/17/2011] [Indexed: 02/07/2023]
Abstract
BACKGROUND The mobile-bearing variant of a single-radius design is assumed to provide more freedom of motion compared to the fixed-bearing variant because the insert does not restrict the natural movements of the femoral component. This would reduce the contact stresses and wear which in turn may have a positive effect on the fixation of the prosthesis to the bone and thereby decreases the risk for loosening. The aim of this study was to evaluate early migration of the tibial component and kinematics of a mobile-bearing and fixed-bearing total knee prosthesis of the same single-radius design. METHODS Twenty Triathlon single-radius posterior-stabilized knee prostheses were implanted (9 mobile-bearing and 11 fixed-bearing). Fluoroscopy and roentgen stereophotogrammetric analysis (RSA) were performed 6 and 12 months post-operatively. FINDINGS The 1 year post-operative RSA results showed considerable early migrations in 3 out of 9 mobile-bearing patients and 1 out of 11 fixed-bearing patients. The range of knee flexion was the same for the mobile-bearing and fixed-bearing group. The mobile insert was following the femoral component during motion. INTERPRETATION Despite the mobile insert following the femoral component during motion, and therefore performing as intended, no kinematic advantages of the mobile-bearing total knee prosthesis were seen. The fixed-bearing knee performed as good as the mobile-bearing knee and maybe even slightly better based on less irregular kinematics and less early migrations.
Collapse
Affiliation(s)
- N Wolterbeek
- Department of Orthopaedics, Leiden University Medical Center, Leiden, The Netherlands
| | | | | | | | | |
Collapse
|
25
|
Argenson JNA, Parratte S, Ashour A, Saintmard B, Aubaniac JM. The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of follow-up. J Bone Joint Surg Am 2012; 94:638-44. [PMID: 22488620 DOI: 10.2106/jbjs.k.00263] [Citation(s) in RCA: 48] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Durable, long-term results have been reported for patients managed with first-generation mobile-bearing total knee arthroplasty. Second-generation mobile-bearing total knee arthroplasty has been introduced to enhance instrumentation, to increase flexion, and to improve functional outcome, but, to our knowledge, no long-term results are available. METHODS From May 1999 to June 2000, 116 consecutive rotating-platform total knee arthroplasties were performed by the two senior authors in 112 patients with use of the LPS-Flex Mobile cemented prosthesis, which was implanted with a measured resection technique. The patella was resurfaced in every knee. The average age of the patients at the time of surgery was sixty-nine years (range, thirty-seven to eighty-five years), and seventy-seven patients (eighty knees) were women. The predominant diagnosis was osteoarthritis. The clinical and radiographic evaluation was performed with use of the Knee Society rating system. The level of activity and patient-reported functional outcome were evaluated with use of the University of California at Los Angeles (UCLA) score and the Knee injury and Osteoarthritis Outcome Score (KOOS), respectively. RESULTS The average duration of follow-up was 10.6 years (range, ten to 11.8 years). Three patients were lost to follow-up, and five patients died of causes unrelated to knee arthroplasty. Two knees were revised, one because of infection and one because of failure of the medial collateral ligament. Kaplan-Meier survivorship analysis showed an implant survival rate of 98.3% at ten years. For the 104 patients (108 knees) who were evaluated at a minimum of ten years, the average Knee Society knee and function scores improved from 34 to 94 points and from 55 to 88 points, respectively, at the time of the latest follow-up. There was no periprosthetic osteolysis and no evidence of implant loosening on follow-up radiographs. The average knee flexion was 117° preoperatively and 128° at the time of the latest follow-up evaluation. At the time of the latest follow-up, the KOOS quality-of-life score was significantly better for patients with >125° of flexion (p = 0.00034). CONCLUSIONS This study demonstrated durable clinical and radiographic results at a minimum of ten years after total knee replacement with a second-generation, cemented, rotating-platform, posterior-stabilized total knee prosthesis. According to the functional outcome results obtained in this study, we believe that this design is a valuable option for active patients undergoing total knee arthroplasty.
Collapse
Affiliation(s)
- Jean-Noel A Argenson
- Service de Chirurgie Orthopédique, Hôpital Sainte-Marguerite, 270, Boulevard Sainte-Marguerite, 13009, Marseille, France. jean-noel.argenson@ap-hm
| | | | | | | | | |
Collapse
|
26
|
Affiliation(s)
- Carl A Deirmengian
- The Rothman Institute, Thomas Jefferson University, 925 Chestnut Street, 5th floor, Philadelphia, PA 19107, USA
| | | |
Collapse
|
27
|
Mahoney OM, Kinsey TL, D’Errico TJ, Shen J. The John Insall Award: no functional advantage of a mobile bearing posterior stabilized TKA. Clin Orthop Relat Res 2012; 470:33-44. [PMID: 22006197 PMCID: PMC3238000 DOI: 10.1007/s11999-011-2114-5] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Mobile bearing (MB) total knee design has been advocated as a means to enhance the functional characteristics and decrease the wear rates of condylar total knee arthroplasty (TKA). However, it is unclear if these designs achieve these goals. QUESTIONS/PURPOSES We asked whether function of patients or survivorship would be greater or complications would be lesser in groups of patients with MB compared with fixed bearing (FB) TKA. We also sought to describe retrieval findings. METHODS We randomized 507 primary TKAs in 416 eligible patients to receive MB (n = 252) or FB (n = 255) devices from November 2001 to August 2007 (Investigational Device Exemption G000180, ClinicalTrials.gov registration number NCT00946075). Patients were blinded to treatment allocation. WOMAC Index, SF-12 Health Survey, knee range of motion, and Knee Society scores were collected and compared preoperatively and at 6, 12, and 24 months postoperatively. We recorded device failures and complications until October 2009. Kaplan-Meier survivorship was compared using the log rank test. Twelve retrieved MB devices underwent pathologic analysis. The minimum postoperative time was 2.2 years (mean, 5.9 years; range, 2.2-7.9 years). RESULTS We found no differences in mean clinical assessment scores or mean score changes from baseline at any postoperative interval through 2 postoperative years. Nineteen of the 252 MB and 13 of the 255 FB knees had undergone revision of any component. Estimated survival at 6 postoperative years was similar for the two devices: 90.1% (95% confidence interval [CI], 84.1-93.9) for MB and 94.2% (95% CI, 90.1-96.6) for FB. Two MB and no FB tibial components were revised for loosening. There was one case of MB insert dislocation. Retrieved MB devices demonstrated no unexpected wear or mechanical device failures. CONCLUSION We found no evidence of functional advantage of the MB design. Survivorship was similar, although the study is limited by short duration of followup.
Collapse
Affiliation(s)
- Ormonde M. Mahoney
- Athens Orthopedic Clinic, PA, 1765 Old West Broad Street, Building 2, Suite 200, Athens, GA 30606 USA ,Department of Kinesiology, University of Georgia, Athens, GA USA
| | - Tracy L. Kinsey
- Athens Orthopedic Clinic, PA, 1765 Old West Broad Street, Building 2, Suite 200, Athens, GA 30606 USA ,Department of Epidemiology, University of North Carolina, Chapel Hill, NC USA
| | | | | |
Collapse
|
28
|
Functional performance of mobile versus fixed bearing total knee prostheses: a randomised controlled trial. Knee Surg Sports Traumatol Arthrosc 2012; 20:1450-5. [PMID: 21946980 PMCID: PMC3402661 DOI: 10.1007/s00167-011-1684-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2010] [Accepted: 09/13/2011] [Indexed: 11/10/2022]
Abstract
PURPOSE The primary goal of this study was to assess the difference in active flexion between patients with a mobile versus a fixed bearing, cruciate retaining, and total knee arthroplasty. The study was designed as a randomised controlled multi-centre trial. METHODS Participants were assigned to interventions by using block-stratified, random allocation. Outcome parameters were active flexion, passive flexion, and Knee Society Score (KSS). Outcome parameters were assessed preoperatively and at 3, 6, and 12 months postoperatively by an independent nurse. RESULTS Ninety-two patients from one centre were included, 46 in each group. Active flexion was comparable for the two groups, 99.9° for the mobile bearing group and 101° for the fixed bearing group with a baseline controlled difference of 1.0 (95% CI -3.9 to 5.8, n.s.). The Clinical KSS was comparable between the two bearing groups (Mobile 90.0 vs. fixed 92.4, n.s.). The functional KSS showed a difference that was attributable to the stair climbing subscore, which showed a difference in favour of the fixed bearing design between preoperative and 3 months (7.3 point difference; 95% CI 2.3-12.5; P = 0.005) as well as 12 months (4.8 point difference; 95% CI 0.1-9.6; P = 0.045). CONCLUSIONS There were no short-term differences in active flexion between fixed bearing and mobile bearing total knee arthroplasty. LEVEL OF EVIDENCE I.
Collapse
|
29
|
Chang CW, Lai KA, Yang CY, Lan SM. Early mechanical complications of a multidirectional mobile-bearing total knee replacement. ACTA ACUST UNITED AC 2011; 93:479-83. [DOI: 10.1302/0301-620x.93b4.25864] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Between April 2004 and July 2007, we performed 241 primary total knee replacements in 204 patients using the e.motion posterior cruciate-retaining, multidirectional mobile-bearing prosthesis. Of these, 100 were carried out using an image-free navigation system, and the remaining 141 with the conventional technique. We conducted a retrospective study from the prospectively collected data of these patients to assess the early results of this new mobile-bearing design. At a mean follow-up of 49 months (32 to 71), 18 knees (7.5%) had mechanical complications of which 13 required revision. Three of these had a peri-prosthetic fracture, and were removed from the study. The indication for revision in the remaining ten was loosening of the femoral component in two, tibiofemoral dislocation in three, disassociation of the polyethylene liner in four, and a broken polyethyene liner in one. There were eight further mechanically unstable knees which presented with recurrent disassociation of the polyethylene liner. There was no significant difference in the incidence of mechanical instability between the navigation-assisted procedures (8 of 99, 8.1%) and the conventionally implanted knees (10 of 139, 7.2%). In our view, the relatively high rate of mechanical complications and revision within 30 months precludes the further use of new design of knee replacement.
Collapse
Affiliation(s)
- C.-W. Chang
- Department of Orthopaedics, National Cheng Kung University Medical Centre, 138, Sheng-Li Road, Tainan City, Taiwan 70428
| | - K.-A. Lai
- Department of Orthopaedics, National Cheng Kung University Medical Centre, 138, Sheng-Li Road, Tainan City, Taiwan 70428
| | - C.-Y. Yang
- Department of Orthopaedics, National Cheng Kung University Medical Centre, 138, Sheng-Li Road, Tainan City, Taiwan 70428
| | - S.-M. Lan
- Department of Orthopaedics, National Cheng Kung University Medical Centre, 138, Sheng-Li Road, Tainan City, Taiwan 70428
| |
Collapse
|