1
|
Beckers G, Morcos MW, Lavigne M, Massé V, Kiss MO, Vendittoli PA. Excellent Results of Large-Diameter Ceramic-On-Ceramic Bearings in Total Hip Arthroplasty at Minimum Ten-Year Follow-Up. J Arthroplasty 2024; 39:3028-3035. [PMID: 38909852 DOI: 10.1016/j.arth.2024.06.045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2023] [Revised: 06/17/2024] [Accepted: 06/18/2024] [Indexed: 06/25/2024] Open
Abstract
BACKGROUND This study reports the minimum 10 years results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head ceramic-on-ceramic bearing. METHODS Of the 276 THAs included in this study, there were eleven deaths and 27 patients lost to follow up (11%) during the follow-up, leaving 237 (85%) hips available for review at a mean of 10.5 years (range, 10 to 12) postoperatively. Reoperations, implant revisions, adverse events, clinical outcomes, radiographic evaluation, and whole blood metal ion levels were assessed at the last follow-up. RESULTS After a minimum of 10 years, implant survivorship was 98.7%. There were 3 revisions (1.3%): one for insufficient acetabular cup primary fixation, one traumatic periprosthetic acetabular fracture, and one probable deep chronic infection. No dislocation or ceramic implant fracture was observed. The mean University of California at Los Angeles activity score, Western Ontario and McMaster Universities Osteoarthritis Index score, and Forgotten Joint Score were 5.6 (2 to 10), 90.1 (9 to 100), and 79.2 (4 to 100), respectively. All patients (100%) were satisfied or very satisfied. Since implantation, 43% of patients reported hearing a squeaking noise from the prosthesis. But all patients who reported squeaking were satisfied with the surgery. The mean titanium level was 2.2 μg/L (1.1 to 5.6). No progressive radiolucent lines, osteolysis, or implant loosening signs were observed at the last radiographic evaluation. CONCLUSIONS A large-diameter head ceramic-on-ceramic THA provides outstanding long-term (minimum 10 years) implant survivorship with unrestricted activity while avoiding implant impingement, liner fracture, and hip instability. Functional outcomes, satisfaction, and joint perception were excellent. Although the incidence of squeaking was high, it did not affect patient satisfaction or function. The systemic titanium levels were low, related to unavoidable passive corrosion of implant surfaces, and did not reveal any indirect signs of trunnionosis.
Collapse
Affiliation(s)
- Gautier Beckers
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada
| | - Mina W Morcos
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada
| | - Vincent Massé
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada
| | - Marc-Olivier Kiss
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montreal, QC, Canada; Clinique Orthopédique Duval, Laval, QC, Canada; Personalized Arthroplasty Society, Atlanta, Georgia
| |
Collapse
|
2
|
Wu T, Guo S, Jiang Y, Shi W, Wang Y, Li T. Ceramic fragmentation after total hip arthroplasty: two case reports and literature review. Front Surg 2024; 11:1357301. [PMID: 38444899 PMCID: PMC10912464 DOI: 10.3389/fsurg.2024.1357301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Accepted: 02/09/2024] [Indexed: 03/07/2024] Open
Abstract
Background Ceramic fragmentation is a rare but serious complication after total hip arthroplasty (THA). We reviewed the PubMed literature from 1990 to 2023 and found only 31 case reports of ceramic fragmentation after THA. Our case reports help to expand understanding of this rare complication. We shared our surgical experience and identified an ideal material for revision surgery, which can serve as a useful reference for other orthopedic surgeons to perform ceramic fragmentation revision surgery in the future. We also analyzed the possible causes, diagnosis, and treatment opinions of ceramic fragmentation. Case presentation This study presents two cases of ceramic fragmentation after THA. One patient had ceramic head fragmentation 10 years after the primary THA, and one patient had ceramic liner fragmentation 5 years after the primary THA. Both patients presented with pain, and one patient also reported a clicking sound in the hip. The two patients described here had BMIs of 23.7 and 23.1, respectively. Both patients' ceramic fragmentation were due to aseptic loosening, not periprosthetic joint infections, as confirmed by negative microbiological cultures. Radiographic examinations of both patients revealed radio-opaque wear debris around the hip joint prostheses and we describe the surgical protocols and intraoperative findings in both cases in detail. Conclusion Our cases and the literature suggest that ceramic fragmentation can occur at any time after THA. The most immediate symptoms are pain and noise, but some patients may be asymptomatic. Ceramic on polyethylene bearings is recommended for revision surgery whenever possible; metal bearings should be avoided.
Collapse
Affiliation(s)
- Tingyu Wu
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Sijia Guo
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Yaping Jiang
- Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Weipeng Shi
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Yingzhen Wang
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Tao Li
- Department of Joint Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| |
Collapse
|
3
|
Kurtz SM, Holyoak DT, Trebše R, Randau TM, Porporati AA, Siskey RL. Ceramic Wear Particles: Can They Be Retrieved In Vivo and Duplicated In Vitro? J Arthroplasty 2023; 38:1869-1876. [PMID: 36966889 DOI: 10.1016/j.arth.2023.03.057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 03/15/2023] [Accepted: 03/19/2023] [Indexed: 04/12/2023] Open
Abstract
BACKGROUND Little is known about retrieved zirconia platelet toughened alumina (ZPTA) wear particles from ceramic-on-ceramic (COC) total hip arthroplasty. Our objectives were to evaluate clinically retrieved wear particles from explanted periprosthetic hip tissues and to analyze the characteristics of in vitro-generated ZPTA wear particles. METHODS Periprosthetic tissue and explants were received for 3 patients who underwent a total hip replacement of ZPTA COC head and liner. Wear particles were isolated and characterized via scanning electron microscopy and energy dispersive spectroscopy. The ZPTA and control (highly cross-linked polyethylene and cobalt chromium alloy) were then generated in vitro using a hip simulator and pin-on-disc testing, respectively. Particles were assessed in accordance with American Society for Testing and Materials F1877. RESULTS Minimal ceramic particles were identified in the retrieved tissue, consistent with the retrieved components demonstrating minimal abrasive wear with material transfer. Average particle diameter from in vitro studies was 292 nm for ZPTA, 190 nm for highly cross-linked polyethylene, and 201 nm for cobalt chromium alloy. CONCLUSION The minimal number of in vivo ZPTA wear particles observed is consistent with the successful tribological history of COC total hip arthroplasties. Due to the relatively few ceramic particles located in the retrieved tissue, in part due to implantation times of 3 to 6 years, a statistical comparison was unable to be made between the in vivo particles and the in vitro-generated ZPTA particles. However, the study provided further insight into the size and morphological characteristics of ZPTA particles generated from clinically relevant in vitro test setups.
Collapse
|
4
|
Park JW, Ko YS, Lee YK, Ha YC, Koo KH. Ten to 13-Year Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty in Patients Less Than 30 Years Old. J Bone Joint Surg Am 2023; 105:789-796. [PMID: 36947597 DOI: 10.2106/jbjs.22.01291] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/24/2023]
Abstract
BACKGROUND We previously reported mid-term results of total hip arthroplasty (THA) using Delta ceramic-on-ceramic (CoC) bearings in 72 patients (86 hips) who were <30 years old. Noise was noted in 8 (9.3%) of the hips, no osteolysis or loosening was detected, and no patient required reoperation. The purpose of this study was to assess clinical and radiographic outcomes, complications, and survivorship at >10 years after THA using Delta CoC bearings in patients who were <30 years old. METHODS Cementless THA with a Delta CoC bearing was performed between March 2008 and January 2012 in 91 hips of 76 patients who were <30 years old. Eighty-five hips in 71 patients (44 men and 27 women) with a mean age of 25.9 years (range, 16 to 29 years) at surgery were followed for a mean of 10.9 years (range, 10 to 13 years). RESULTS No ceramic bearings fractured. The incidence of squeaking increased to 5.9% (5 of 85), but the squeaking was not reproducible within individual patients. Periprosthetic osteolysis developed in 3 hips (3 patients): around the stem in 2 and around the metal shell in 1. The stem in 1 hip underwent revision because of a Vancouver type-B2 periprosthetic femoral fracture. One patient with systemic lupus erythematosus underwent irrigation and debridement for periprosthetic joint infection. Survivorship free of reoperation for any reason was 92.4% (95% confidence interval, 82.4% to 100%) at 13 years. CONCLUSIONS The long-term results and survivorship of Delta CoC THA in patients <30 years old were favorable. LEVEL OF EVIDENCE Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Jung-Wee Park
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Young-Seung Ko
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Seoul Bumin Hospital, Seoul, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
- Kay Joint Center, Cheil Orthopaedic Hospital, Seoul, South Korea
| |
Collapse
|
5
|
Park JW, Kim HS, Kim KC, Lee YK, Ha YC, Koo KH. A 10- to 12-year follow-up study of delta ceramic-on-ceramic total hip arthroplasty. Arch Orthop Trauma Surg 2023:10.1007/s00402-022-04758-x. [PMID: 36595032 DOI: 10.1007/s00402-022-04758-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 12/28/2022] [Indexed: 01/04/2023]
Abstract
BACKGROUND We previously reported five-to-seven-year results of total hip arthroplasty (THA) with the use of delta ceramic-on-ceramic (CoC) bearing. We conducted an extension study with a CT scan at a minimum of 10 years after surgery. METHODS From March 2009 to March 2011, 273 patients (310 hips) received cementless THA with delta CoC bearing, porous-coated cup and hydroxyapatite-coated stem. In this extended study, 252 patients (144 men and 108 women) (288 hips) with a mean age of 49.7 years (16-83) at surgery were followed for a mean of 10.4 years (10-12) with CT scans in 133 hips (46.2%, 133/288). Clinical and radiographic evaluations were made at each follow-up and Kaplan-Meier survival analysis was performed with revision and reoperation as endpoints. RESULTS There were no more ceramic fractures. Compared to mid-term results, the incidence of squeaking and RLLs increased to 3.1% (9/288) and 19.4% (56/288), respectively. The RLL progressed to focal osteolysis in 3 hips (5.4%, 3/56). No hip had detectable wear or prosthetic loosening. Two hips were reoperated due to periprosthetic joint infection and periprosthetic femoral fracture in each. The survivorship decreased to 98.3% (96.7-99.9%) at 12 years. CONCLUSION During the extended follow-up, no additional ceramic fracture occurred, and the incidence of squeak increased by 0.7%. The long-term survivorship of Delta CoC THA was encouraging. However, focal osteolysis occurred around the hydroxyapatite-coated stem in 1% (3/288). LEVEL OF EVIDENCE II (Prospective cohort study).
Collapse
Affiliation(s)
- Jung-Wee Park
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-Ro, Bundang-gu, Seongnam, 463-707, South Korea.,Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Hong-Seok Kim
- Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, South Korea.,Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea
| | - Ki-Choul Kim
- Department of Orthopaedic Surgery, Dankook University Hospital, Cheonan, South Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-Ro, Bundang-gu, Seongnam, 463-707, South Korea. .,Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul, South Korea.
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Seoul Bumin Hospital, Seoul, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, 166 Gumi-Ro, Bundang-gu, Seongnam, 463-707, South Korea.,Department of Orthopaedic Surgery, Kay Joint Center, Cheil Orthopaedic Hospital, Seoul, South Korea
| |
Collapse
|
6
|
Blumenfeld TJ, Politi J, Coker S, O’Dell T, Hamilton W. Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty. Arthroplast Today 2022; 13:130-135. [PMID: 35106349 PMCID: PMC8784293 DOI: 10.1016/j.artd.2021.11.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Accepted: 11/12/2021] [Indexed: 11/28/2022] Open
Abstract
Background Ceramic-on-ceramic (COC) bearings in total hip arthroplasty (THA) have long been considered the coupling with the lowest overall wear. However, concerns about complications such as ceramic breakage and noise, combined with the improved performance of polyethylene, have limited its use in the United States. This postapproval follow-up reports long-term (10 years) results of Delta COC in THA patients primarily enrolled in an Investigational Device Exemption study. Methods Patients received Delta COC THA in a prospective multicenter study with either 28-mm (N = 105 hips in 104 patients) or 36-mm (N = 81) articulations. Annual clinical and radiographic evaluations were performed for years 5 to 10, and study patients were asked about hip noises and reproducibility. Results There have been 4 additional reports of noise in 4 patients (COC 28, n = 3; COC 36, n = 1). The cumulative incidence rate for squeaking or noise at 10 years is 5.9% for COC 28 and 13.5% for COC 36. There have been 2 additional reports of dislocation in 2 patients (COC 28, n = 1; COC 36, n = 1). The cumulative incidence rate for dislocation at 10 years is 3.7% for COC 28 and 3.5% for COC 36. At 10 years, there were greater than 40 hips available for follow-up. At mean 10-year follow-up, there were a total of 3 ceramic liner fractures, but none since the previous report. There were no revisions in the 28-mm cohort, and 2 revisions in the 36-mm cohort (1 for recurrent dislocation and 1 for pain and noise). Overall Kaplan-Meier survivorship was 95.96% at 10.5 years (28 mm: 97.68% at 10.2 years; 36 mm: 94.11% at 10.4 years.) Conclusions At 10-year follow-up, we report excellent results in regard to survivorship, with one patient revised for pain with associated squeaking.
Collapse
Affiliation(s)
- Thomas J. Blumenfeld
- Department of Orthopaedic Surgery, Stanford University, Pleasanton, CA, USA
- Corresponding author. Stanford University, 5725 West Las Positas Boulevard, Suite 200, Pleasanton, CA 94608, USA. Tel.: +1 916 806 7534.
| | | | | | | | - William Hamilton
- Anderson Orthopedic Research Institute, Inova Center for Joint Replacement, Alexandria, VA, USA
| |
Collapse
|
7
|
Bahraminasab M, Arab S, Safari M, Talebi A, Kavakebian F, Doostmohammadi N. In vivo performance of Al 2O 3-Ti bone implants in the rat femur. J Orthop Surg Res 2021; 16:79. [PMID: 33482866 PMCID: PMC7821505 DOI: 10.1186/s13018-021-02226-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 01/11/2021] [Indexed: 11/17/2022] Open
Abstract
Background Alumina-titanium (Al2O3-Ti) biocomposites have been recently developed with improved mechanical properties for use in heavily loaded orthopedic sites. Their biological performance, however, has not been investigated yet. Methods The aim of the present study was to evaluate the in vivo biological interaction of Al2O3-Ti. Spark plasma sintering (SPS) was used to fabricate Al2O3-Ti composites with 25 vol.%, 50 vol.%, and 75 vol.% Ti content. Pure alumina and titanium were also fabricated by the same procedure for comparison. The fabricated composite disks were cut into small bars and implanted into medullary canals of rat femurs. The histological analysis and scanning electron microscopy (SEM) observation were carried out to determine the bone formation ability of these materials and to evaluate the bone-implant interfaces. Results The histological observation showed the formation of osteoblast, osteocytes with lacuna, bone with lamellar structures, and blood vessels indicating that the healing and remodeling of the bone, and vasculature reconstruction occurred after 4 and 8 weeks of implantation. However, superior bone formation and maturation were obtained after 8 weeks. SEM images also showed stronger interfaces at week 8. There were differences between the composites in percentages of bone area (TB%) and the number of osteocytes. The 50Ti composite showed higher TB% at week 4, while 25Ti and 75Ti represented higher TB% at week 8. All the composites showed a higher number of osteocytes compared to 100Ti, particularly 75Ti. Conclusions The fabricated composites have the potential to be used in load-bearing orthopedic applications.
Collapse
Affiliation(s)
- Marjan Bahraminasab
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran. .,Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran.
| | - Samaneh Arab
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran.,Department of Tissue Engineering and Applied Cell Sciences, School of Medicine, Semnan University of Medical Sciences, Semnan, Iran
| | - Manouchehr Safari
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Athar Talebi
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Fatemeh Kavakebian
- Nervous System Stem Cells Research Center, Semnan University of Medical Sciences, Semnan, Iran
| | - Nesa Doostmohammadi
- Faculty of Metallurgical and Materials Engineering, Semnan University, Semnan, Iran
| |
Collapse
|
8
|
Lee S, Yoo JJ, Kim HJ. Impingement Between the Metal Stem and the Ceramic Liner in Total Hip Arthroplasty: The Neck Is Not the Only Place Where Impingement Occurs. J Bone Joint Surg Am 2021; 103:139-145. [PMID: 33269897 DOI: 10.2106/jbjs.20.00354] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND It is assumed that impingement between the ceramic liner and the stem increases the possibility of a liner fracture in total hip arthroplasty with a ceramic-on-ceramic bearing. The purpose of this study was to analyze the pattern of the impingement by evaluating the notches (U-shaped indented wear scars engraved on the stem) on radiographs to determine when and where impingement develops and to analyze the factors affecting its occurrence. METHODS Among the primary total hip arthroplasty cases using a ceramic-on-ceramic bearing performed from November 1997 to December 2003, 244 cases of 197 patients (123 male patients and 74 female patients) that had follow-up of ≥15 years were included. All of the radiographs were examined with special regard to the notches and the cup positions. RESULTS Notches were detected at 77 sites of 57 cases (23.4%) for the first time between 8 months and 14.8 years after the surgical procedure. They were located on the neck or the shoulder of the stem. Shoulder notches were detected only in the cases with a short-neck head. Shoulder notches were found in 29 cases (20.0% of short-neck cases). Cup inclination was lower (p = 0.01) and anteversion was higher (p = 0.01) in the group with notches than the group without notches. There were 5 cases of ceramic head fracture. One of them experienced another ceramic liner fracture, assumed to be caused by prosthetic shoulder impingement, after the revision surgical procedure. CONCLUSIONS The results of this study suggest that impingement between the stem and the ceramic liner occurs in a considerable proportion of patients who underwent total hip arthroplasty not only on the neck but also on the shoulder of the stem. Forceful and abrupt impingement on the stem shoulder can cause ceramic liner fracture. Impingement between the stem shoulder and the ceramic liner should be considered in designing a stem. It seems to be prudent to recommend that patients avoid squatting or sitting cross-legged on the floor as much as possible. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Sunhyung Lee
- Department of Orthopaedic Surgery, Seoul National University Hospital, Seoul, Republic of Korea
| | | | | |
Collapse
|
9
|
Davis ET, Remes V, Virolainen P, Gebuhr P, Van Backlé B, Revell MP, Kopjar B. Mid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty. J Orthop Surg Res 2021; 16:35. [PMID: 33422084 PMCID: PMC7797157 DOI: 10.1186/s13018-020-02192-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2020] [Accepted: 12/28/2020] [Indexed: 11/10/2022] Open
Abstract
Background Whilst bony fixation of hip replacement has stable solutions, there remains controversy over which bearing best optimizes longevity and function. Ceramic-on-ceramic (CoC) bearing combinations are associated with lower risk of revision due to aseptic loosening and dislocation. Evidence for long-term functional outcomes of modern, 4th generation CoC bearings is limited. The aim of this study was to analyze outcomes and complications of the R3™ Acetabular System (Smith & Nephew, Inc., Cordova, TN, USA) in combination with BIOLOX® Delta ceramic femoral head in patients undergoing primary total hip arthroplasty (THA). Methods Between June 2009 and May 2011, 175 patients (178 hips) were enrolled into a prospective, study at 6 sites in Europe and prospectively followed-up at 3 months and 1, 3, 5, and 7 years postoperative. Results Total WOMAC score improved from 63 (range, 22–91) preoperative to 8 (range, 0–8) at 1-year follow-up and remained unchanged at 7-year follow-up. Modified Harris hip score improved from 45 (range, 10–87) preoperative to 83 (range, 25–100) at 3 months, 91 (range, 42–100) at 1 year, and 92 (range, 46, 100) at 7 years. UCLA Activity Rating Scale score improved from 3.3 (range, 1–8) preoperative to 6.2 (range, 2–8) at 1 year; it marginally declined to 5.8 (range, 3–8) at 7-year follow-up. There were 4 trochanteric fractures and 5 patients died of unrelated reasons. Three hips were revised (2 periprosthetic fractures and 1 subluxation). The 7-year cumulative survival rate was 98.3%. Conclusion Clinical and functional improvements of THA with CoC bearing are maintained at 7 years postoperative. Trial registration ClinicalTrials.Gov, NCT03566082, Registered 10 January 2018—retrospectively registered,
Collapse
Affiliation(s)
- Edward T Davis
- The Royal Orthopaedic Hospital, NHS Foundation Trust, Bristol Road South, Northfield, Birmingham, B31 2AP, UK.
| | - Ville Remes
- Department of Orthopedics, HUS Peijaksen sairaala, P.O. Box 900, 00029 HUS, Vantaa, Finland
| | - Petri Virolainen
- Turku University Hospital, Kiinamyllynkatu 4-8, P.O Box 52, 20521, Turku, Finland
| | - Peter Gebuhr
- Orthopaedic Surgeon, Department of Orthopaedics, Hvidovre University Hospital, Copenhagen, Denmark
| | - Bart Van Backlé
- AZ Nikolaas, Sint Niklaas, Regentiestraat, 60, 9100, Sint Niklaas, Belgium
| | - Matthew P Revell
- The Royal Orthopaedic Hospital, NHS Foundation Trust, Bristol Road South, Northfield, Birmingham, B31 2AP, UK
| | - Branko Kopjar
- Department of Health Services, University of Washington, H690C, Health Sciences Building, P.O. Box 357660, Seattle, WA, 98195-7660, USA
| |
Collapse
|
10
|
Bistolfi A, Ferracini R, Aprato A, Massè A, Daghino W, Lea S, Artiaco S, Lee GC. Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up. J Orthop 2020; 22:397-401. [PMID: 32968340 DOI: 10.1016/j.jor.2020.08.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 08/23/2020] [Indexed: 02/08/2023] Open
Abstract
Purpose to evaluate the results of Delta ceramic-on-ceramic (CoC) for total-hip-arthroplasty (THA). Methods 261 THA using Delta-CoC, retrospectively analyzed. A 36 mm head was used in 189 cases and a 32/40 mm in the others. The series have been compared to a group of 89 THA with Forte-CoC. Results The Harris-Hip-Score improved from 49.1 ± 14.3 to 92.0 ± 8.9 (P < 0.001). In the Delta group there were one ceramic fracture and 2 dislocations. Two hips underwent revision. There were one revision in the Forte group for instability and one squeaking hip. Conclusions The new ceramic bearings provides a safe bearing for THA, with rare complications.
Collapse
Affiliation(s)
- Alessandro Bistolfi
- AO Città Della Salute e Della Scienza. Department of Orthopeadics, Traumatology and Rehabilitative Medicine, CTO Hospital, Turin, Italy
| | - Riccardo Ferracini
- Hoelloker Orthopaedics, Turin Italy. University of the Studies of Genova. Genova, Italy
| | - Alessandro Aprato
- AO Città Della Salute e Della Scienza. Department of Orthopeadics, Traumatology and Rehabilitative Medicine, CTO Hospital, Turin, Italy
| | - Alessandro Massè
- AO Città Della Salute e Della Scienza. Department of Orthopeadics, Traumatology and Rehabilitative Medicine, CTO Hospital, Turin, Italy.,Hoelloker Orthopaedics, Turin Italy. University of the Studies of Genova. Genova, Italy.,University of the Studies of Turin, Turin, Italy
| | - Walter Daghino
- AO Città Della Salute e Della Scienza. Department of Orthopeadics, Traumatology and Rehabilitative Medicine, CTO Hospital, Turin, Italy
| | - Sara Lea
- University of the Studies of Turin, Turin, Italy
| | - Stefano Artiaco
- AO Città Della Salute e Della Scienza. Department of Orthopeadics, Traumatology and Rehabilitative Medicine, CTO Hospital, Turin, Italy
| | - Gwo-Chin Lee
- Hospital of the University of Pennsylvania, Penn Presbyterian Medical Center, Pennsylvania Hospital, USA
| |
Collapse
|
11
|
Yoon BH, Park JW, Cha YH, Won SH, Lee YK, Ha YC, Koo KH. Incidence of Ceramic Fracture in Contemporary Ceramic-on-Ceramic Total Hip Arthroplasty: A Meta-analysis of Proportions. J Arthroplasty 2020; 35:1437-1443.e3. [PMID: 31902618 DOI: 10.1016/j.arth.2019.12.013] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Revised: 12/02/2019] [Accepted: 12/09/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We performed a proportion meta-analysis of currently available data to determine the prevalence of ceramic fracture for each generation. METHODS A total of 10,571 total hip arthroplasties from 45 studies were included. Proportion meta-analysis with a random-effects model was performed to estimate the prevalence of ceramic fracture. To determine whether the ceramic fractures have a fatigue nature and a risk or latent period for the development, postoperative time lapse, patient age, and body mass index were related with ceramic fracture by metaregression analysis. RESULTS As of postoperative 2.0 to 18.8 years, the rate of ceramic fracture was 0.5% (95% CI, 0.3%-0.8%) in the forte group and 0.2% (95% CI, 0.1%-0.4%) in the delta group (P = .059). The ceramic fracture rate for each component was 0.2% (95% CI, 0.1%-0.3%) for the forte head, 0.1% (95% CI, 0.0%-0.2%) for the delta head (P = .210), 0.2% (95% CI, 0.1%-0.3%) for the forte liner, and 0.2% (95% CI, 0.1%-0.4%) for the delta liner (P = .305). The rate of ceramic fracture per 1000 patient-years was 0.9 (95% CI, 0.5-0.13) in the forte group and 0.5 (95% CI, 0.2-0.8) in the delta group (P = .072). In metaregression analysis, no significant associations were found between prevalence of ceramic fracture and postoperative time lapse, patient age, or body mass index. CONCLUSIONS The rate of ceramic fracture was 0.9/1000 patient-year in the forte group and 0.5/1000 patient-year in the delta group. The results of this study provide baseline data for further studies validating ceramic bearings. LEVEL OF EVIDENCE Level I, meta-analysis.
Collapse
Affiliation(s)
- Byung-Ho Yoon
- Department of Orthopaedic Surgery, Inje University College of Medicine, Seoul Paik Hospital, Seoul, South Korea
| | - Jung-Wee Park
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Yong-Han Cha
- Department of Orthopaedic Surgery, Eulji University College of Medicine, Seoul, South Korea
| | - Suk-Hyung Won
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam, South Korea
| |
Collapse
|
12
|
Konan S, Alazzawi S, Yoon BH, Cha YH, Koo KH. A focused update on preventing ceramic fractures in hip arthroplasty. Bone Joint J 2019; 101-B:897-901. [DOI: 10.1302/0301-620x.101b8.bjj-2019-0309.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Ceramic bearings have several desirable properties, such as resistance to wear, hardness, and biocompatibility, that favour it as an articulating surface in hip arthroplasty. However, ceramic fracture remains a concern. We have reviewed the contemporary literature, addressing the factors that can influence the incidence of ceramic bearing surface fracture. Cite this article: Bone Joint J 2019;101-B:897–901.
Collapse
Affiliation(s)
- S. Konan
- Princess Grace Hospital, London, UK
| | - S. Alazzawi
- Orthopaedic Department, University of British Columbia Hospital and Vancouver General Hospital, Vancouver, Canada
| | - B-H. Yoon
- Inje University Seoul Paik Hospital, Seoul, South Korea
| | - Y-H. Cha
- Orthopedic Surgery, Eulji University Hospital, Daejeon, South Korea
| | - K-H. Koo
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, South Korea
| |
Collapse
|
13
|
Kim SC, Lim YW, Jo WL, Park HW, Han SB, Kwon SY, Kim YS. Fourth-generation ceramic-on-ceramic THA results in improvements in midterm outcomes compared to third-generation THA but does not resolve noise problems: a cohort study of a single-hip system. BMC Musculoskelet Disord 2019; 20:263. [PMID: 31142296 PMCID: PMC6542023 DOI: 10.1186/s12891-019-2641-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2017] [Accepted: 05/17/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Using data from the Korean Hip Registry, we aimed to investigate mid-term clinical and radiographic outcomes, including the prevalence of periprosthetic joint infection (PJI), osteolysis, and component loosening or dislocation, and to analyze the incidence of bearing-related complications following modern ceramic-on-ceramic (COC) total hip arthroplasty (THA) using a single cementless hip system. METHODS Four hundred eighty-two patients (602 hips) who underwent Forte or Delta COC THAs with a single hip system and had a minimum 5-year follow-up were identified. The sample included 243 (50.4%) women and 239 (49.6%) men with a mean age of 50.6 years (range: 18-83 years). The Forte group comprised 310 hips, and the Delta group comprised 292 hips. The mean follow-up was 6.1 years (range: 5-10.2 years). RESULTS Cup orientation did not differ between groups. No hip had a PJI or osteolysis in either group. All acetabular components and all but two femoral components (in the Delta group) were well fixed. Dislocations occurred in six (1.9%) hips in the Forte group and one (0.3%) hip in the Delta group (p = 0.124). A total of nine (1.5%) revisions were performed. The 5-year survival rates for all-cause revisions were 98.4 and 98.6%, respectively. One (0.3%) ceramic head fracture occurred in the Forte group. Sixteen (5%) hips exhibited clicking and 6 (2%) hips had squeaking in the Forte group; 16 (6%) hips exhibited clicking and 5 (2%) hips had squeaking in the Delta group. Multiple regression analysis revealed that noise generation was unassociated with any factor. CONCLUSIONS From the Korean Hip Registry data, THA with modern ceramic bearings showed encouraging results, with lower risks of PJI, osteolysis, and component loosening. In particular, Delta COC THA resulted in no PJI or ceramic fracture and had a reduced dislocation risk. However, associated noise remains a concern.
Collapse
Affiliation(s)
- Seung-Chan Kim
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Young-Wook Lim
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea
| | - Woo-Lam Jo
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea
| | - Hyun-Woo Park
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea
| | - Sung-Bin Han
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Soon-Yong Kwon
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Yong-Sik Kim
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Banpo-daero 222, Seocho-gu, Seoul, 137-701, South Korea.
| |
Collapse
|
14
|
Primary total hip arthroplasty with fourth-generation ceramic bearings: Clinical and survival results with a minimum follow-up of 5 years. Rev Esp Cir Ortop Traumatol (Engl Ed) 2019. [DOI: 10.1016/j.recote.2018.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
15
|
Cho KJ, Park KS, Jang WY, Park CG, Yoon TR. Midterm Results of Fourth-Generation Ceramic-On-Ceramic Total Hip Arthroplasty. Indian J Orthop 2019; 53:630-636. [PMID: 31488932 PMCID: PMC6699215 DOI: 10.4103/ortho.ijortho_192_18] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE There are limited reports for the results of the fourth-generation ceramic-on-ceramic (CoC) articulation total hip arthroplasty (THA). And, throughout the surgical experience, we encountered some cases of liner pulling-out phenomenon after liner fixation and femoral preparation. The objective of this study was to evaluate the incidence, risk factors of delta ceramic liner or head fractures, and also the clinical and radiological results of using the fourth-generation CoC articulation in THA. PATIENTS AND METHODS We retrospectively reviewed 242 patients (263 hips) who underwent primary THA using the fourth-generation CoC articulation with a minimum followup of 2 years. Demographic data, Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Patient's satisfactory level were recorded. The radiological evaluation was used to evaluate the implant fixation and complications. Mean followup duration was 5.2 years. RESULTS Mean HHS and WOMAC score were significantly (P < 0.05) improved at the last followup. About 98.5% of the patients were satisfied with results of the surgery. All acetabular components were placed in adequate position and there was no osteolysis on acetabular or femoral components and subsidence of femoral stem. Four patients showed complications including one-liner fracture. CONCLUSION Our midterm study demonstrated excellent clinical and radiological results with only one ceramic liner fracture. Moreover, the results of this study indicate that one possible cause of pulling-out phenomenon is the resonance effect during implantation in Dorr type A patients with the thick cortex. If the surgeon is aware of the liner malposition throughout the operation, the fourth-generation CoC articulation THA could be an outstanding treatment.
Collapse
Affiliation(s)
- Kyu-Jin Cho
- Center for Joint Disease, Chonnam National University Hwasun Hospital, Jeonnam, South Korea
| | - Kyung-Soon Park
- Center for Joint Disease, Chonnam National University Hwasun Hospital, Jeonnam, South Korea
| | - Won-Young Jang
- Orthopaedic Department, Chonnam National University Hospital, Gwangju, South Korea
| | - Chun-Gon Park
- Orthopaedic Department, Chonnam National University Hospital, Gwangju, South Korea
| | - Taek-Rim Yoon
- Center for Joint Disease, Chonnam National University Hwasun Hospital, Jeonnam, South Korea,Address for correspondence: Prof. Taek-Rim Yoon, Department of Orthopaedic Surgery, Chonnam National University Hwasun Hospital, 160 Ilsimri, Hwasun-Gun, Jeonnam 519-809, South Korea. E-mail:
| |
Collapse
|
16
|
Yoo JI, Ha YC, Kim DH, Lee YK, Koo KH. Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study. Indian J Orthop 2019; 53:637-640. [PMID: 31488933 PMCID: PMC6699214 DOI: 10.4103/ortho.ijortho_416_18] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Contemporary ceramic articulation in total hip arthroplasty (THA) has shown successful clinical and radiologic outcomes at mid-to-long term. Delta ceramic, which includes 24% zirconia, has been developed to reduce the rate of ceramic fracture. However, the phase transformation of the zirconia that might cause surface roughness, ceramic wear, and subsequent osteolysis remains a concern. The purpose of this study was to evaluate clinicoradiological outcomes, ceramic-related complications, and survivorship of THA with the use of hybrid ceramic bearing; BIOLOX delta liner-on-BIOLOX forte head articulation at a minimum followup of 10 years. MATERIALS AND METHODS One hundred cementless THAs (85 patients) were performed with the use of 36-mm hybrid ceramic bearing. The thickness of the delta ceramic liner was 4-6 mm. Four patients (4 hips) were lost and six patients (6 hips) died within 10 years after the operation. Thus, the remaining 75 patients (90 hips) were followed up for 10-12 years. There were 43 men and 32 women. The mean age of these patients at the index operation was 58 years (21-78 years). RESULTS There were no fractures of ceramic liner or head. There was no measurable ceramic wear, and neither pelvic nor femoral osteolysis was identified. All acetabular and femoral components were bone-ingrown. Three (3/90, 3.3%) patients noted noise of clicking sound. The mean Harris hip score was 87 points (range 72-99 points) at the time of final followup. THA survivorship with revision surgery as an endpoint was 97.8% (95% confidence interval: 91.4%-99.8%). CONCLUSIONS The long term result of cementless THA with the use of a large BIOLOX forte head on the BIOLOX delta liner showed an encouraging result. Wear or osteolysis associated with composite of 24% zirconia in the fourth-generation ceramic was not observed at a minimum followup of 10 years.
Collapse
Affiliation(s)
- Jun-Il Yoo
- Department of Orthopaedic Surgery, Gyeongsang National University Hospital, Jinju, South Korea
| | - Yong-Chan Ha
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea,Address for correspondence: Dr. Yong-Chan Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, 102 Heukseok-ro, Dongjak-ku, Seoul 156-755, South Korea. E-mail:
| | - Dong-Hyun Kim
- Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, South Korea
| | - Young-Kyun Lee
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Bundang, South Korea
| | - Kyung-Hoi Koo
- Department of Orthopaedic Surgery, Seoul National University Bundang Hospital, Bundang, South Korea
| |
Collapse
|
17
|
Novoa-Parra CD, Pelayo-de Tomás JM, Gómez-Aparicio S, López-Trabucco RE, Morales-Suárez-Varela M, Rodrigo-Pérez JL. Primary total hip arthroplasty with fourth-generation ceramic bearings: Clinical and survival results with a minimum follow-up of 5 years. Rev Esp Cir Ortop Traumatol (Engl Ed) 2018; 63:110-121. [PMID: 30348517 DOI: 10.1016/j.recot.2018.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2018] [Revised: 06/26/2018] [Accepted: 07/18/2018] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE To evaluate the clinical results and survival of primary hip prosthesis with ceramic delta bearings (C-C) with a minimum follow-up of 5years. MATERIAL AND METHOD A total of 205 primary hip arthroplasties performed between 2008 and 2012 were studied. The clinical results, pre-surgical and at 5years of follow-up were evaluated using the Harris Hip Score (HHS), the Short Form-36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the visual analogue scale (VAS). The position of the prosthetic components, periprosthetic osteolysis, loosening of the prosthetic components and ruptures of the ceramic components were studied radiologically. The adverse events related to bearings were recorded according to their diameter, paying special attention to prosthetic dislocations and the presence of noise. Survival with an endpoint of prosthetic revision for any cause was estimated using the Kaplan-Meier method. RESULTS Significant improvements were obtained in the HHS (88.7% of good/excellent results), SF36, WOMAC and EVA, P<.001. There were 19 adverse events related to the prosthesis (4 periprosthetic fractures, 4 dislocations, 2 superficial infections, 1 mobilization of the cup, 2 noises, 4 aseptic loosenings and 2 breaks of the prosthetic neck); 47.3% needed revision. The cumulative survival of the prostheses was 97.5% (95%CI: 96.4-98.5). No differences were found in survival, prosthetic adverse events, noise incidence or dislocations and clinical results among the different diameters used. CONCLUSIONS Primary hip prostheses with fourth-generation ceramic bearings showed good survival in the medium term, and good clinical results.
Collapse
Affiliation(s)
- C D Novoa-Parra
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Dr. Peset, Valencia, España.
| | - J M Pelayo-de Tomás
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Dr. Peset, Valencia, España; Departamento de Anatomía Humana, Universidad de Valencia, Valencia, España
| | - S Gómez-Aparicio
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Dr. Peset, Valencia, España
| | - R E López-Trabucco
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Dr. Peset, Valencia, España
| | - M Morales-Suárez-Varela
- Departamento de Medicina Preventiva, Universidad de Valencia, Valencia, España; CIBER Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, España
| | - J L Rodrigo-Pérez
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario Dr. Peset, Valencia, España; Departamento de Anatomía Humana, Universidad de Valencia, Valencia, España
| |
Collapse
|
18
|
Lim SJ, Ryu HG, Eun HJ, Park CW, Kwon KB, Park YS. Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up. J Arthroplasty 2018; 33:2182-2186.e1. [PMID: 29599034 DOI: 10.1016/j.arth.2018.02.045] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 02/08/2018] [Accepted: 02/08/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to evaluate the minimum 5-year outcomes and bearing-specific complications in a single surgeon series of fourth-generation alumina ceramic-on-ceramic total hip arthroplasties (THAs). METHODS We retrospectively analyzed 667 patients (749 hips) who underwent primary THAs by a single surgeon using fourth-generation alumina ceramic bearings. There were 315 men and 352 women with a mean age of 54.2 years. The surgeon used cementless prostheses with an identical design and BIOLOX Delta ceramics in all hips, using a 36-mm head in 472 hips (63%) and a 32-mm head in 227. The mean follow-up duration was 6.5 years (range, 5 to 8 years). RESULTS The mean Harris hip score improved from 45.6 points preoperatively to 91.3 points at final follow-up. All but 1 acetabular cup and all femoral stems were well fixed. No radiographic evidence of osteolysis was identified at final follow-up. There were 2 (0.3%) ceramic liner fractures and no ceramic head fractures. A total of 48 hips (6.4%) exhibited audible noise (29 clickings and 19 squeakings), but no patient required revision. Other complications were 1 dislocation, 1 deep infection, 3 iliopsoas tendonitis, and 6 periprosthetic femoral fractures. Kaplan-Meier survivorship for revision for any reason was 98.6% (95% confidence interval, 97.7-99.5) at 6.5 years. CONCLUSION Delta ceramic-on-ceramic THAs had a high rate of survivorship without radiographic evidence of osteolysis at 6.5-year follow-up. However, we found 0.3% ceramic liner fractures and 6.4% audible noises associated with the use of Delta ceramics.
Collapse
Affiliation(s)
- Seung-Jae Lim
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hyung-Gon Ryu
- Department of Orthopaedic Surgery, Seoul Medical Center, Seoul, Korea
| | - Hyeon-Jun Eun
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Chan-Woo Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Kyeu-Back Kwon
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Youn-Soo Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|