1
|
Maniar AR, Kazarian GS, Torres-Ramirez RJ, Ranawat AS. Isolated Zone 2 and Zone 3 Cementless Tibial Fixation Shows Early Promise in Revision Total Knee Arthroplasty. Indian J Orthop 2025; 59:673-680. [PMID: 40321476 PMCID: PMC12044109 DOI: 10.1007/s43465-025-01354-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Accepted: 02/09/2025] [Indexed: 05/08/2025]
Abstract
Background Fixation in revision total knee arthroplasty(rTKA) should occur in at least 2 zones(epiphysis, metaphysis, or diaphysis) to maximize fixation strength. We report here the short-term survivorship of unsupported tibial base plates in rTKA when used with a cementless metaphyseal sleeve and non-cemented stem. Methods We retrospectively reviewed all patients undergoing rTKA between 2014 and 2021 by a single surgeon at a single institute. We identified 17 patients with a minimum follow-up of 1 year. Results The average age at surgery was 66.4 years (range 50-80) and the average BMI was 34.6 (range 22.4-43.3). One patient had Type 1 and 16 patients had Type 2 bone loss preoperatively (Anderson Orthopaedic Research Institute classification). Two patients (11.8%) received a standard posterior stabilized insert, nine patients (52.9%) received a varus valgus constrained insert and the remaining 6 (35.3%) patients received a hinged implant. There were no cases of revision for loosening, fracture or mechanical failure of the tibial component construct at an average follow up of 2.9 years (maximum 7.9 years). One patient required revision for end of stem pain. Only 1 patient developed subsidence (≤ 3 mm) but did not have any clinical mechanical symptoms suggestive of loosening. Conclusion We report a 100% survivorship free of revision for loosening or mechanical failure of the tibial construct at short term follow up when using an unsupported tibial base plate with a metaphyseal sleeve and non-cemented stem. Based on early data, metaphyseal sleeves with a stable stem fixation in the tibia can be used without additional tibial tray fixation with cement.
Collapse
Affiliation(s)
- Adit R. Maniar
- Lilavati Hospital and Research Centre, Mumbai, India
- Breach Candy Hospital Trust, Mumbai, India
| | | | | | | |
Collapse
|
2
|
Megaloikonomos PD, AlShehri Y, Garbuz DS, Howard LC, Neufeld ME, Masri BA. Metaphyseal Fixation in Revision Total Knee Arthroplasty. J Bone Joint Surg Am 2025:00004623-990000000-01442. [PMID: 40279440 DOI: 10.2106/jbjs.24.01094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/27/2025]
Abstract
➢ Bone defect management is challenging, but essential, in revision total knee arthroplasty.➢ Appropriate metaphyseal fixation is crucial for stability and implant support.➢ Allografts have been traditionally used to address large defects, but the advent of highly porous metaphyseal cones and sleeves has attracted attention during the past years.➢ Metaphyseal implants are now available in a variety of shapes and sizes to meet various clinical needs.➢ These devices can successfully fill large defects, can better support revision implants, and can achieve long-term biologic fixation.➢ Very good intermediate-term outcomes have been reported with the available metaphyseal implants, using fully cemented or press-fit stems.➢ More research is warranted to further assess surgical indications and the strengths and weaknesses of the various implants used for metaphyseal fixation.
Collapse
|
3
|
Fraval A, Baeza-Oliete J, Bartosz P, Velázquez Moreno JD, Hube R, Huo M, Sanz-Ruiz P, Rajgopal A. What Are the Indications for Using Sleeves and/or Cones During Revision Total Knee Arthroplasty? J Arthroplasty 2025; 40:S162-S163. [PMID: 39454839 DOI: 10.1016/j.arth.2024.10.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2024] [Revised: 10/10/2024] [Accepted: 10/14/2024] [Indexed: 10/28/2024] Open
Affiliation(s)
- Andrew Fraval
- Department of Orthopaedics, St Vincent's Hospital, Melbourne Australia
| | - Jose Baeza-Oliete
- Septic and Reconstructive Surgery Unit, Orthopaedic and Traumatology Section, Hospital Universitari i Politècnic la Fe, Valencia, Spain
| | - Pawel Bartosz
- Centre of Postgraduate Medical Education, Orthopaedic Department, Gruca Orthopaedic and Trauma Teaching Hospital, Otwock, Poland
| | | | - Robert Hube
- Orthopädische Chirurgie München, Munich, Germany
| | - Michael Huo
- Department of Orthopaedic Surgery, University of Texas Southwestern Medical Center, Dallas, Texas
| | - Pablo Sanz-Ruiz
- Department of Traumatology and Orthopaedic Surgery, General University Hospital Gregorio Marañón, Madrid, Spain
| | - Ashok Rajgopal
- Department of Orthopaedics, Fortis Bone and Joint Institute, New Delhi, India
| |
Collapse
|
4
|
Hadley ML, Harmer JR, Wright BH, Larson DR, Abdel MP, Berry DJ, Lewallen DG. Porous Tantalum Tibial Metaphyseal Cones in Revision Total Knee Arthroplasty: Excellent 10-Year Survivorship. J Arthroplasty 2024; 39:S263-S269. [PMID: 38677340 DOI: 10.1016/j.arth.2024.04.059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Revised: 04/17/2024] [Accepted: 04/18/2024] [Indexed: 04/29/2024] Open
Abstract
BACKGROUND Highly porous metal tibial metaphyseal cones (TMCs) are commonly utilized in revision total knee arthroplasty (TKA) to address bone loss and obtain biologic fixation. Mid-term (5 to 10 year) studies have previously demonstrated excellent survivorship and high rates of osseointegration, but longer-term studies are lacking. We aimed to assess long-term (≥ 10 year) implant survivorship, complications, and clinical and radiographic outcomes after revision TKA with TMCs. METHODS Between 2004 and 2011, 228 revision TKAs utilizing porous tantalum TMCs with stemmed tibial components were performed at a single institution and were retrospectively reviewed. The mean age at revision was 65 years, the mean body mass index was 33, and 52% were women. Implant survivorship, complications, and clinical and radiographic outcomes were assessed. The mean follow-up was 6.3 years. RESULTS The 10-year survivorship free of aseptic loosening leading to TMC removal was 97%, free of any TMC removal was 88%, free of any re-revision was 66%, and free of any reoperation was 58%. The most common indications for re-revision were periprosthetic joint infection, instability, and aseptic femoral component loosening. The 10-year nonoperative complication rate was 24%. The mean Knee Society scores increased from 38 preoperatively to 69 at 10 years. There were 8 knees that had evidence of partial, progressive tibial radiolucencies at 10 years. CONCLUSIONS Porous tantalum TMCs demonstrated persistently durable longer-term survivorship with a low rate of implant removal. The rare implant removals for component loosening or instability were offset by those required for periprosthetic joint infection, which accounted for 80% of cone removals. Porous tantalum TMCs provide an extremely reliable tool to address tibial bone loss and achieve durable long-term fixation in revision TKA. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Matthew L Hadley
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Joshua R Harmer
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Breydan H Wright
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Dirk R Larson
- Division of Clinical Trials and Biostatistics, Department of Quantitative Health Sciences, Mayo Clinic, Rochester, Minnesota
| | - Matthew P Abdel
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - David G Lewallen
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
5
|
Li X, Zhu L, Che Z, Liu T, Yang C, Huang L. Progress of research on the surface functionalization of tantalum and porous tantalum in bone tissue engineering. Biomed Mater 2024; 19:042009. [PMID: 38838694 DOI: 10.1088/1748-605x/ad5481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 06/05/2024] [Indexed: 06/07/2024]
Abstract
Tantalum and porous tantalum are ideal materials for making orthopedic implants due to their stable chemical properties and excellent biocompatibility. However, their utilization is still affected by loosening, infection, and peripheral inflammatory reactions, which sometimes ultimately lead to implant removal. An ideal bone implant should have exceptional biological activity, which can improve the surrounding biological microenvironment to enhance bone repair. Recent advances in surface functionalization have produced various strategies for developing compatibility between either of the two materials and their respective microenvironments. This review provides a systematic overview of state-of-the-art strategies for conferring biological functions to tantalum and porous tantalum implants. Furthermore, the review describes methods for preparing active surfaces and different bioactive substances that are used, summarizing their functions. Finally, this review discusses current challenges in the development of optimal bone implant materials.
Collapse
Affiliation(s)
- Xudong Li
- The Second Hospital of Jilin University, Changchun 130041, People's Republic of China
| | - Liwei Zhu
- The Second Hospital of Jilin University, Changchun 130041, People's Republic of China
| | - Zhenjia Che
- The Second Hospital of Jilin University, Changchun 130041, People's Republic of China
| | - Tengyue Liu
- The Second Hospital of Jilin University, Changchun 130041, People's Republic of China
| | - Chengzhe Yang
- The Second Hospital of Jilin University, Changchun 130041, People's Republic of China
| | - Lanfeng Huang
- The Second Hospital of Jilin University, Changchun 130041, People's Republic of China
| |
Collapse
|
6
|
Stroobant L, de Taeye T, Byttebier P, Van Onsem S, Jacobs E, Burssens A, Victor J. Condylar constrained and rotating hinged implants in revision knee arthroplasty show similar survivorship and clinical outcome: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2023; 31:5365-5380. [PMID: 37747534 DOI: 10.1007/s00167-023-07572-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 09/03/2023] [Indexed: 09/26/2023]
Abstract
PURPOSE In revision total knee arthroplasty (TKA) ligament instability and bone defects might require more constraint implants such as a condylar constrained knee (CCK) or rotating hinged knee (RHK). When both implants are suitable, the choice remains controversial. The purpose of this systematic review and meta-analysis was to compare the survivorship and clinical outcome between CCK and RHK in revision TKA. METHODS Systematic literature research was performed. Studies analysing the clinical outcome and/or survivorship of CCK and/or RHK in revision TKA were included. Clinical outcomes included the Knee Society Score, both clinical (KSCS) and functional (KSFS), range of motion (ROM) and reoperations. Survival was defined as the time free from removal or revision of the femoral and/or tibial component. RESULTS A total of 40 articles analysing 4.555 knees were included. Survival did not differ between RHK and CCK implants (p = 0.6058), with, respectively, 91.6% and 89.8% survival after 5 years. Postoperative KSCS and KSFS were, respectively, 79.2 (SD 10.7) and 61.1 (SD 21.8) for the CCK group. Similar scores were noted for the RHK group with a KSCS of 80.2 (SD 14.1) and KSFS of 58.5 (SD 17.3). Postoperative ROM was similar for CCK (105.3°, SD 17.1°) and RHK patients (104.1°, SD 16.9°). CONCLUSION This meta-analysis revealed that both survivorship and clinical outcome are similar for CCK and RHK patients for whom both designs are technically suitable and indicated. LEVEL OF EVIDENCE IV.
Collapse
Affiliation(s)
- Lenka Stroobant
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium.
| | - Thijmen de Taeye
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium
| | - Paul Byttebier
- Department Orthopaedic Surgery, ASZ Aalst, Aalst, Belgium
| | | | - Ewoud Jacobs
- Department of Rehabilitation Sciences, Ghent University Faculty of Medicine and Health Sciences, Ghent, Belgium
| | - Arne Burssens
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium
| | - Jan Victor
- Department Orthopaedic Surgery, University Hospital Ghent, Ghent, Belgium
| |
Collapse
|
7
|
Eder-Halbedl M, Fink A, Pietsch M, Djahani O, Hofmann S. Excellent mid- to long-term survival of tantalum metal cones in a case series of revision knee arthroplasty with severe bony defects. Knee Surg Sports Traumatol Arthrosc 2023; 31:5496-5506. [PMID: 37819600 PMCID: PMC10719141 DOI: 10.1007/s00167-023-07593-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Accepted: 09/11/2023] [Indexed: 10/13/2023]
Abstract
PURPOSE Severe metaphyseal bone defects remain a challenge and represent a growing problem in revision total knee arthroplasty (RTKA). The purpose of this study was to examine the survival of first-generation tantalum metal cones (TMC) and to assess clinical and radiographic data obtained from mid- to long-term follow-ups (FU) after RTKA with severe bony defects. METHODS This retrospective case series included 100 consecutive patients of the same centre, who underwent RTKA surgery with TMC for tibia and/or femur bone defects between January 2011 and December 2015. Fourteen patients had died and six were lost for FU, leaving a total of eighty patients (one hundred and twelve TMC) for final evaluation. Clinical parameters including the Knee Society Score (KSS), visual analogue scale (VAS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM) were determined preoperatively based on the patients' medical charts, and assessed again during the final FU after an average of 6.1 (5-9) years postoperative. Standardised postoperative X-rays were analysed during the final FU visit for osseointegration of the cones, and any signs of implant loosening were assessed with the modified Knee Society Radiographic review criteria. Perioperative and postoperative complications, reoperations, as well as implant and cone re-revisions were analysed. Survivorship analysis was performed with (a) cone-related revision for any reason and (b) implant component revision for any reason. RESULTS Previous RTKA had to be performed due to 64 (80%) aseptic and 16 (20%) septic failures. At the final FU, 75 (94%) tibia and 76 (95%) femur TMCs and implants were clinically stable. One patient experienced loosening of cones and implants at the femur and tibia but denied re-revision surgery. There were eight (10%) reoperations including two early wound healing problems, two inlay changes, two periprosthetic fractures, one debridement, antibiotics and implant retention (DAIR), and one secondary patella replacement. The six (7.5%) re-revisions included two aseptic loosening's of the opposite implant without TMC, one arthrodesis for recurrent instability, and three deep infections managed by two two-stage exchanges, and one amputation for persistent infection. At re-revision, all TMC cones were osteointegrated without signs of loosening. The determined clinical parameters showed significant (p < 0.001) postoperative improvement, and objective KSS was rated as excellent in 51%, and as good in 22% of patients at the final FU. The estimated 8-year Kaplan-Meier survival was 95% for TMC and 92.5% for implant components. CONCLUSION Tantalum metal cones (TMC) demonstrate a secure fixation for treatment of severe femoral and tibial metaphyseal bone defects during RTKA. This fixation concept showed excellent mid- to long-term clinical and radiographic outcomes with promising 8-year survival rates for cones and implant components. LEVEL OF EVIDENCE Retrospective cohort study, Level IV.
Collapse
Affiliation(s)
- Michael Eder-Halbedl
- Department of Orthopedics and Traumatology, LKH Feldbach-Fürstenfeld, Ottokar-Kernstock-Straße 18, 8330, Feldbach, Austria.
| | - Andrea Fink
- Department of Orthopedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Martin Pietsch
- Department of Orthopedics, LKH-Murtal, Stolzalpe, Stolzalpe 38, 8852, Murau, Austria
| | - Oliver Djahani
- Department of Orthopedics, LKH-Murtal, Stolzalpe, Stolzalpe 38, 8852, Murau, Austria
| | - Siegfried Hofmann
- Department of Orthopedics and Traumatology, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
- Department of Orthopedics, LKH-Murtal, Stolzalpe, Stolzalpe 38, 8852, Murau, Austria
| |
Collapse
|
8
|
De Martino I, Mancino F, Di Matteo V, Singlitico A, Maccauro G, Gasparini G. Tantalum Cones for Severe Bone Defects in Revision Knee Arthroplasty: A Minimum 10-Year Follow-Up. J Arthroplasty 2023; 38:886-892. [PMID: 36481282 DOI: 10.1016/j.arth.2022.11.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 11/14/2022] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Two-to 6-year results of reconstruction of severe bone defects in revision total knee arthroplasty (TKA) with highly porous tantalum cones have been encouraging, but 10-year follow-up is lacking. The purpose of this study was to determine the minimum 10-year results of tantalum cones in revision TKA. METHODS From 2005 to 2010, 30 consecutive patients (30 knees) underwent revision TKA with the use of cones. All patients were followed clinically and radiographically for a minimum of 10 years. A total of 42 cones (25 tibial and 17 femoral) were used to reconstruct massive bone defects classified as Anderson Orthopaedic Research Institute Types 2A (10), 2B (12), and 3 (19). The mean age of the patients was 73 years (range, 55 to 84) at the time of revision. The indication for the revision included aseptic loosening (15 patients) and second-stage reimplantation for deep infection (15 patients). Six patients were lost to follow-up. RESULTS In total, 6 cones had to be revised. Minimum 10-year cone survivorship for any reason was 81% (25 of 31 cones). With cone revision for aseptic loosening as the end point, survivorship was 96% (30 of 31). No evidence of loosening or migration of any implant was noted on the most recent radiographs. CONCLUSION Metaphyseal fixation with tantalum cones in revision TKA demonstrated excellent survivorship and fixation at a minimum follow-up of 10 years. This type of metaphyseal reconstruction can be a durable option for revision TKA in patients who have massive bone defects.
Collapse
Affiliation(s)
- Ivan De Martino
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Roma, Italy; Università Cattolica del Sacro Cuore, Roma, Italy
| | - Fabio Mancino
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Roma, Italy; Università Cattolica del Sacro Cuore, Roma, Italy
| | - Vincenzo Di Matteo
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Roma, Italy; Università Cattolica del Sacro Cuore, Roma, Italy
| | - Alessandro Singlitico
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Roma, Italy; Università Cattolica del Sacro Cuore, Roma, Italy
| | - Giulio Maccauro
- Adult Reconstruction and Joint Replacement Service, Division of Orthopaedics and Traumatology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Roma, Italy; Università Cattolica del Sacro Cuore, Roma, Italy
| | - Giorgio Gasparini
- Orthopedic Surgery Division, Department of Medical and Surgical Sciences, University of Catanzaro Magna Græcia, Catanzaro, Italy
| |
Collapse
|