1
|
Park J, Ghanim R, Rahematpura A, Gerage C, Abramson A. Electromechanical convective drug delivery devices for overcoming diffusion barriers. J Control Release 2024; 366:650-667. [PMID: 38190971 PMCID: PMC10922834 DOI: 10.1016/j.jconrel.2024.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 01/02/2024] [Accepted: 01/03/2024] [Indexed: 01/10/2024]
Abstract
Drug delivery systems which rely on diffusion for mass transport, such as hydrogels and nanoparticles, have enhanced drug targeting and extended delivery profiles to improve health outcomes for patients suffering from diseases including cancer and diabetes. However, diffusion-dependent systems often fail to provide >0.01-1% drug bioavailability when transporting macromolecules across poorly permeable physiological tissues such as the skin, solid tumors, the blood-brain barrier, and the gastrointestinal walls. Convection-enabling robotic ingestibles, wearables, and implantables physically interact with tissue walls to improve bioavailability in these settings by multiple orders of magnitude through convective mass transfer, the process of moving drug molecules via bulk fluid flow. In this Review, we compare diffusive and convective drug delivery systems, highlight engineering techniques that enhance the efficacy of convective devices, and provide examples of synergies between the two methods of drug transport.
Collapse
Affiliation(s)
- Jihoon Park
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Ramy Ghanim
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Adwik Rahematpura
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Caroline Gerage
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Alex Abramson
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; Division of Digestive Diseases, Emory University School of Medicine, Atlanta, GA 30322, USA.
| |
Collapse
|
2
|
Fine J, McShane MJ, Coté GL. Monte Carlo method for assessment of a multimodal insertable biosensor. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-210299SSRR. [PMID: 35505461 PMCID: PMC9064117 DOI: 10.1117/1.jbo.27.8.083017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 04/12/2022] [Indexed: 05/25/2023]
Abstract
SIGNIFICANCE Continuous glucose monitors (CGMs) are increasingly utilized as a way to provide healthcare to the over 10% of Americans that have diabetes. Fully insertable and optically transduced biosensors are poised to further improve CGMs by extending the device lifetime and reducing cost. However, optical modeling of light propagation in tissue is necessary to ascertain device performance. AIM Monte Carlo modeling of photon transport through tissue was used to assess the luminescent output of a fully insertable glucose biosensor that uses a multimodal Förster resonance energy transfer competitive binding assay and a phosphorescence lifetime decay enzymatic assay. APPROACH A Monte Carlo simulation framework of biosensor luminescence and tissue autofluorescence was built using MCmatlab. Simulations were first validated against previous research and then applied to predict the response of a biosensor in development. RESULTS Our results suggest that a diode within the safety standards for light illumination on the skin, with far-red excitation, allows the luminescent biosensor to yield emission strong enough to be detectable by a common photodiode. CONCLUSIONS The computational model showed that the expected fluorescent power output of a near-infrared light actuated barcode was five orders of magnitude greater than a visible spectrum excited counterpart biosensor.
Collapse
Affiliation(s)
- Jesse Fine
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
| | - Michael J. McShane
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M University, Department of Materials Science and Engineering, College Station, Texas, United States
- Texas A&M University, Center for Remote Health Technologies and Systems, Texas A&M Engineering Experiment Station, College Station, Texas, United States
| | - Gerard L. Coté
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M University, Center for Remote Health Technologies and Systems, Texas A&M Engineering Experiment Station, College Station, Texas, United States
| |
Collapse
|
3
|
Kumosa LS, Schouenborg J. Profound alterations in brain tissue linked to hypoxic episode after device implantation. Biomaterials 2021; 278:121143. [PMID: 34653937 DOI: 10.1016/j.biomaterials.2021.121143] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Accepted: 09/20/2021] [Indexed: 12/17/2022]
Abstract
To enable authentic interfacing with neuronal structures in the brain, preventing alterations of tissue during implantation of devices is critical. By transiently implanting oxygen microsensors into rat cortex cerebri for 2 h, substantial and long lasting (>1 h) hypoxia is routinely generated in surrounding tissues; this hypoxia is linked to implantation generated compressive forces. Preferential loss of larger neurons and reduced metabolic components in surviving neurons indicates decreased viability one week after such hypoxic, compressive implantations. By devising an implantation method that relaxes compressive forces; magnitude and duration of hypoxia generated following such an implantation are ameliorated and neurons appear similar to naïve tissues. In line with these observations, astrocyte proliferation was significantly more pronounced for more hypoxic, compressive implantations. Surprisingly, astrocyte processes were frequently found to traverse cellular boundaries into nearby neuronal nuclei, indicating injury induction of a previously not described astrocyte-neuron interaction. Found more frequently in less hypoxic, force-relaxed insertions and thus correlating to a more beneficial outcome, this finding may suggest a novel protective mechanism. In conclusion, substantial and long lasting insertion induced hypoxia around brain implants, a previously overlooked factor, is linked to significant adverse alterations in nervous tissue.
Collapse
Affiliation(s)
- Lucas S Kumosa
- Neuronano Research Center, Faculty of Medicine, Lund University, Scheelevägen 2, Medicon Village 404A2, 223 81, Lund, Sweden.
| | - Jens Schouenborg
- Neuronano Research Center, Faculty of Medicine, Lund University, Scheelevägen 2, Medicon Village 404A2, 223 81, Lund, Sweden; NanoLund, Lund University, Professorsgatan 1, 223 63, Lund, Sweden.
| |
Collapse
|
4
|
Han EX, Wang J, Kural M, Jiang B, Leiby KL, Chowdhury N, Tellides G, Kibbey RG, Lawson JH, Niklason LE. Development of a Bioartificial Vascular Pancreas. J Tissue Eng 2021; 12:20417314211027714. [PMID: 34262686 PMCID: PMC8243137 DOI: 10.1177/20417314211027714] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Accepted: 06/08/2021] [Indexed: 12/16/2022] Open
Abstract
Transplantation of pancreatic islets has been shown to be effective, in some patients, for the long-term treatment of type 1 diabetes. However, transplantation of islets into either the portal vein or the subcutaneous space can be limited by insufficient oxygen transfer, leading to islet loss. Furthermore, oxygen diffusion limitations can be magnified when islet numbers are increased dramatically, as in translating from rodent studies to human-scale treatments. To address these limitations, an islet transplantation approach using an acellular vascular graft as a vascular scaffold has been developed, termed the BioVascular Pancreas (BVP). To create the BVP, islets are seeded as an outer coating on the surface of an acellular vascular graft, using fibrin as a hydrogel carrier. The BVP can then be anastomosed as an arterial (or arteriovenous) graft, which allows fully oxygenated arterial blood with a pO2 of roughly 100 mmHg to flow through the graft lumen and thereby supply oxygen to the islets. In silico simulations and in vitro bioreactor experiments show that the BVP design provides adequate survivability for islets and helps avoid islet hypoxia. When implanted as end-to-end abdominal aorta grafts in nude rats, BVPs were able to restore near-normoglycemia durably for 90 days and developed robust microvascular infiltration from the host. Furthermore, pilot implantations in pigs were performed, which demonstrated the scalability of the technology. Given the potential benefits provided by the BVP, this tissue design may eventually serve as a solution for transplantation of pancreatic islets to treat or cure type 1 diabetes.
Collapse
Affiliation(s)
- Edward X Han
- Department of Biomedical Engineering,
Yale School of Engineering and Applied Science, New Haven, CT, USA
| | - Juan Wang
- Vascular Biology and Therapeutics
Program, Yale School of Medicine, New Haven, CT, USA
- Department of Anesthesiology, Yale
School of Medicine, New Haven, CT, USA
| | - Mehmet Kural
- Vascular Biology and Therapeutics
Program, Yale School of Medicine, New Haven, CT, USA
- Department of Anesthesiology, Yale
School of Medicine, New Haven, CT, USA
| | - Bo Jiang
- Department of Surgery, Yale School of
Medicine, New Haven, CT, USA
- Department of Vascular Surgery, The
First Hospital of China Medical University, Shenyang, China
| | - Katherine L Leiby
- Department of Biomedical Engineering,
Yale School of Engineering and Applied Science, New Haven, CT, USA
| | - Nazar Chowdhury
- Molecular, Cellular, and Developmental
Biology, Yale University, New Haven, CT, USA
| | - George Tellides
- Vascular Biology and Therapeutics
Program, Yale School of Medicine, New Haven, CT, USA
- Department of Surgery, Yale School of
Medicine, New Haven, CT, USA
- Veterans Affairs Connecticut Healthcare
System, West Haven, CT, USA
| | - Richard G Kibbey
- Department of Internal Medicine
(Endocrinology), Yale University, New Haven, CT, USA
- Department of Cellular & Molecular
Physiology, Yale School of Medicine, New Haven, CT, USA
| | - Jeffrey H Lawson
- Department of Surgery, Duke
University, Durham, NC, USA
- Humacyte Inc., Durham, NC, USA
| | - Laura E Niklason
- Department of Biomedical Engineering,
Yale School of Engineering and Applied Science, New Haven, CT, USA
- Vascular Biology and Therapeutics
Program, Yale School of Medicine, New Haven, CT, USA
- Department of Anesthesiology, Yale
School of Medicine, New Haven, CT, USA
- Humacyte Inc., Durham, NC, USA
| |
Collapse
|
5
|
Joseph JI. Review of the Long-Term Implantable Senseonics Continuous Glucose Monitoring System and Other Continuous Glucose Monitoring Systems. J Diabetes Sci Technol 2021; 15:167-173. [PMID: 32345047 PMCID: PMC7783000 DOI: 10.1177/1932296820911919] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The article published by Kevin Cowart in this issue of the Journal of Diabetes Science and Technology (JDST) is a detailed overview of the clinical trial data and analysis used to demonstrate the safety and effectiveness of the Eversense continuous glucose monitoring (CGM) System for regulatory approval and clinical acceptance. The article describes the published study results for safety, accuracy, reliability, ease of insertion/removal, adverse events, and ease of diabetes patient-use for controlling their glucose levels short and long term. The author nicely compares Eversense CGM System safety and performance with the short-term subcutaneous tissue CGM systems being commercialized by Dexcom, Medtronic Diabetes, and Abbott Diabetes. This comparison may help the clinician define which type of patient with diabetes might benefit the most from the long-term implantable CGM system. The majority of studied patients describe a positive experience managing their diabetes with the Eversense CGM System and request implantation of a new sensor 90 or 180 days later.
Collapse
Affiliation(s)
- Jeffrey I. Joseph
- Jeffrey I. Joseph, DO, Department of Anesthesiology, Sidney Kimmel Medical College, Jefferson Artificial Pancreas Center, Thomas Jefferson University, 1020 Locust Street, JAH # 565, Philadelphia, PA 19072, USA.
| |
Collapse
|
6
|
Monitoring with In Vivo Electrochemical Sensors: Navigating the Complexities of Blood and Tissue Reactivity. SENSORS 2020; 20:s20113149. [PMID: 32498360 PMCID: PMC7308849 DOI: 10.3390/s20113149] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 05/29/2020] [Accepted: 05/31/2020] [Indexed: 12/18/2022]
Abstract
The disruptive action of an acute or critical illness is frequently manifest through rapid biochemical changes that may require continuous monitoring. Within these changes, resides trend information of predictive value, including responsiveness to therapy. In contrast to physical variables, biochemical parameters monitored on a continuous basis are a largely untapped resource because of the lack of clinically usable monitoring systems. This is despite the huge testing repertoire opening up in recent years in relation to discrete biochemical measurements. Electrochemical sensors offer one of the few routes to obtaining continuous readout and, moreover, as implantable devices information referable to specific tissue locations. This review focuses on new biological insights that have been secured through in vivo electrochemical sensors. In addition, the challenges of operating in a reactive, biological, sample matrix are highlighted. Specific attention is given to the choreographed host rejection response, as evidenced in blood and tissue, and how this limits both sensor life time and reliability of operation. Examples will be based around ion, O2, glucose, and lactate sensors, because of the fundamental importance of this group to acute health care.
Collapse
|
7
|
Tang WH, Ho WH, Chen YJ. Data assimilation and multisource decision-making in systems biology based on unobtrusive Internet-of-Things devices. Biomed Eng Online 2018; 17:147. [PMID: 30396337 PMCID: PMC6218968 DOI: 10.1186/s12938-018-0574-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Biological and medical diagnoses depend on high-quality measurements. A wearable device based on Internet of Things (IoT) must be unobtrusive to the human body to encourage users to accept continuous monitoring. However, unobtrusive IoT devices are usually of low quality and unreliable because of the limitation of technology progress that has slowed down at high peak. Therefore, advanced inference techniques must be developed to address the limitations of IoT devices. This review proposes that IoT technology in biological and medical applications should be based on a new data assimilation process that fuses multiple data scales from several sources to provide diagnoses. Moreover, the required technologies are ready to support the desired disease diagnosis levels, such as hypothesis test, multiple evidence fusion, machine learning, data assimilation, and systems biology. Furthermore, cross-disciplinary integration has emerged with advancements in IoT. For example, the multiscale modeling of systems biology from proteins and cells to organs integrates current developments in biology, medicine, mathematics, engineering, artificial intelligence, and semiconductor technologies. Based on the monitoring objectives of IoT devices, researchers have gradually developed ambulant, wearable, noninvasive, unobtrusive, low-cost, and pervasive monitoring devices with data assimilation methods that can overcome the limitations of devices in terms of quality measurement. In the future, the novel features of data assimilation in systems biology and ubiquitous sensory development can describe patients' physical conditions based on few but long-term measurements.
Collapse
Affiliation(s)
- Wei-Hua Tang
- Division of Cardiology, Department of Internal Medicine, National Yang-Ming University Hospital, Yilan, Taiwan
| | - Wen-Hsien Ho
- Department of Healthcare Administration and Medical Informatics, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Medical Research, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Yenming J. Chen
- Department of Logistics Management, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
| |
Collapse
|
8
|
Lorenzi T, Venkataraman C, Lorz A, Chaplain MAJ. The role of spatial variations of abiotic factors in mediating intratumour phenotypic heterogeneity. J Theor Biol 2018; 451:101-110. [PMID: 29750997 DOI: 10.1016/j.jtbi.2018.05.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2017] [Revised: 05/01/2018] [Accepted: 05/02/2018] [Indexed: 12/21/2022]
Abstract
We present here a space- and phenotype-structured model of selection dynamics between cancer cells within a solid tumour. In the framework of this model, we combine formal analyses with numerical simulations to investigate in silico the role played by the spatial distribution of abiotic components of the tumour microenvironment in mediating phenotypic selection of cancer cells. Numerical simulations are performed both on the 3D geometry of an in silico multicellular tumour spheroid and on the 3D geometry of an in vivo human hepatic tumour, which was imaged using computerised tomography. The results obtained show that inhomogeneities in the spatial distribution of oxygen, currently observed in solid tumours, can promote the creation of distinct local niches and lead to the selection of different phenotypic variants within the same tumour. This process fosters the emergence of stable phenotypic heterogeneity and supports the presence of hypoxic cells resistant to cytotoxic therapy prior to treatment. Our theoretical results demonstrate the importance of integrating spatial data with ecological principles when evaluating the therapeutic response of solid tumours to cytotoxic therapy.
Collapse
Affiliation(s)
- Tommaso Lorenzi
- School of Mathematics and Statistics, University of St Andrews, St Andrews KY16 9SS, United Kingdom
| | | | - Alexander Lorz
- CEMSE Division, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia; Sorbonne Universités, UPMC Univ Paris 06, UMR 7598, Laboratoire Jacques-Louis Lions, Paris, France
| | - Mark A J Chaplain
- School of Mathematics and Statistics, University of St Andrews, St Andrews KY16 9SS, United Kingdom.
| |
Collapse
|
9
|
Coffel J, Nuxoll E. BioMEMS for biosensors and closed-loop drug delivery. Int J Pharm 2018; 544:335-349. [PMID: 29378239 DOI: 10.1016/j.ijpharm.2018.01.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2017] [Revised: 01/10/2018] [Accepted: 01/14/2018] [Indexed: 12/14/2022]
Abstract
The efficacy of pharmaceutical treatments can be greatly enhanced by physiological feedback from the patient using biosensors, though this is often invasive or infeasible. By adapting microelectromechanical systems (MEMS) technology to miniaturize such biosensors, previously inaccessible signals can be obtained, often from inside the patient. This is enabled by the device's extremely small footprint which minimizes both power consumption and implantation trauma, as well as the transport time for chemical analytes, in turn decreasing the sensor's response time. MEMS fabrication also allows mass production which can be easily scaled without sacrificing its high reproducibility and reliability, and allows seamless integration with control circuitry and telemetry which is already produced using the same materials and fabrication steps. By integrating these systems with drug delivery devices, many of which are also MEMS-based, closed loop drug delivery can be achieved. This paper surveys the types of signal transduction devices available for biosensing-primarily electrochemical, optical, and mechanical-looking at their implementation via MEMS technology. The impact of MEMS technology on the challenges of biosensor development, particularly safety, power consumption, degradation, fouling, and foreign body response, are also discussed.
Collapse
Affiliation(s)
- Joel Coffel
- Department of Chemical and Biochemical Engineering, 4133 Seamans Center for the Engineering Arts & Sciences, University of Iowa, Iowa City, IA 52242, USA
| | - Eric Nuxoll
- Department of Chemical and Biochemical Engineering, 4133 Seamans Center for the Engineering Arts & Sciences, University of Iowa, Iowa City, IA 52242, USA.
| |
Collapse
|
10
|
Kumosa LS, Zetterberg V, Schouenborg J. Gelatin promotes rapid restoration of the blood brain barrier after acute brain injury. Acta Biomater 2018; 65:137-149. [PMID: 29037893 DOI: 10.1016/j.actbio.2017.10.020] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Revised: 09/27/2017] [Accepted: 10/10/2017] [Indexed: 12/25/2022]
Abstract
Gelatin coating of brain implants is known to provide considerable benefits in terms of reduced inflammatory sequalae and long-term neuroprotective effects. However, the mechanisms for gelatin's protective role in brain injury are still unknown. To address this question, cellular and molecular markers were studied with quantitative immunohistochemical microscopy at acute (<2hours, 1, 3days), intermediate (1-2 weeks) and long-term time points (6 weeks) after transient insertion of stainless steel needles into female rat cortex cerebri with or without gelatin coating. Compared to non-coated controls, injuries caused by gelatin coated needles showed a significantly faster resolution of post-stab bleeding/leakage and differential effects on different groups of microglia cells. While similar levels of matrix metalloproteinase (MMP-2 and MMP-9, two gelatinases) was found for coated and noncoated needle stabs during the first week, markedly increased levels of both MMPs was seen for gelatin-coated but not non-coated needle stabs after 2weeks. Neuronal populations and activated astrocytes were largely unaffected. In conclusion, the beneficial effects of gelatin may be the combined results of faster healing of the blood brain barrier curtailing leakage of blood borne molecules/cells into brain parenchyma and to a modulation of the microglial population response favoring restitution of the injured tissue. These findings present an important therapeutic potential for gelatin coatings in various disease, injury and surgical conditions. STATEMENT OF SIGNIFICANCE The neural interfaces field holds great promise to enable elucidation of neural information processing and to develop new implantable devices for stimulation based therapy. Currently, this field is struggling to find solutions for reducing tissue reactions to implanted micro and nanotechnology. Prior studies have recently shown that gelatin coatings lower activation of digestive microglia and mitigate the ubiquitous loss of neurons adjacent to implanted probes, both of which impede implant function. The underlying mechanisms remain to be elucidated, however. Our findings demonstrate for the first time that gelatin has a significant effect on the BBB by promoting rapid restoration of integrity after injury. Moreover, gelatin alters microglia phenotypes and modulates gelatinase activity for up to 2weeks favoring anti-inflammation and restoration of the tissue. Given the key importance of the BBB for normal brain functions, we believe our findings have substantial significance and will be highly interesting to researchers in the biomaterial field.
Collapse
|
11
|
Biswas A, Bornhoeft LR, Banerjee S, You YH, McShane MJ. Composite Hydrogels Containing Bioactive Microreactors for Optical Enzymatic Lactate Sensing. ACS Sens 2017; 2:1584-1588. [PMID: 29043796 DOI: 10.1021/acssensors.7b00648] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Continuously monitoring specific biomarkers offer a promising method to interrogate disease status and progression. In this work we have demonstrated a composite hydrogel-based sensing platform that may be used for optical detection of lactate. The sensor design consists of microsized enzymatic sensors that are embedded in an outer hydrogel matrix. In these engineered microdomains, encapsulated lactate oxidase serves as the bioactive component, phosphorescent metalloporphyrin acts as the optical transducer, and polyelectrolyte multilayers coated on the enzymatic microsensors control the permeation of lactate into the microsensors. The response of the composite hydrogel-based lactate sensors was characterized by subjecting the sensors to lactate concentration challenges at low physiological oxygen levels. The analytical range and the mean sensitivity were determined to be 9.2 ± 0.83 mg/dL and 11 ± 0.90% dL mg-1, respectively. Repeated cyclic exposure to high levels of lactate revealed that these sensors were extremely stable, with no significant loss in sensor response after 20 cycles. These preliminary results support the premise that these composite hydrogels are capable of continuous lactate tracking and have the potential for use as fully implantable optical lactate sensors.
Collapse
Affiliation(s)
- Aniket Biswas
- Department of Biomedical Engineering, ‡Department of Biology, and §Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Lindsey R. Bornhoeft
- Department of Biomedical Engineering, ‡Department of Biology, and §Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Swayoma Banerjee
- Department of Biomedical Engineering, ‡Department of Biology, and §Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Yil-Hwan You
- Department of Biomedical Engineering, ‡Department of Biology, and §Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| | - Michael J. McShane
- Department of Biomedical Engineering, ‡Department of Biology, and §Department of Materials Science and Engineering, Texas A&M University, College Station, Texas 77843, United States
| |
Collapse
|
12
|
Composite Hydrogels with Engineered Microdomains for Optical Glucose Sensing at Low Oxygen Conditions. BIOSENSORS-BASEL 2017; 7:bios7010008. [PMID: 28117762 PMCID: PMC5371781 DOI: 10.3390/bios7010008] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2016] [Revised: 01/14/2017] [Accepted: 01/16/2017] [Indexed: 12/20/2022]
Abstract
There is a growing need for advanced tools that enable frequent monitoring of biomarkers for precision medicine. In this work, we present a composite hydrogel-based system providing real-time optical bioanalyte monitoring. The responsive material, alginate-in-alginate (AnA), is comprised of an alginate hydrogel with embedded bioactive, nanofilm-coated phosphorescent microdomains; palladium tetracarboxyphenylporphyrin serves as an optical indicator, glucose oxidase as a model enzyme, and layer-by-layer deposited polyelectrolyte multilayers (PEMs) as the diffusion barrier. Glutaraldehyde crosslinking of the nanofilms resulted in a dramatic reduction in glucose diffusion (179%) while oxygen transport was not significantly affected. The responses of the AnA hydrogels to step changes of glucose at both ambient and physiological oxygen levels were evaluated, revealing controlled tuning of sensitivity and dynamic range. Stability, assessed by alternately exposing the responsive AnA hydrogels to extremely high and zero glucose concentrations, resulted in no significant difference in the response over 20 cycles. These AnA hydrogels represent an attractive approach to biosensing based on biocompatible materials that may be used as minimally-invasive, implantable devices capable of optical interrogation. The model glucose-responsive composite material studied in this work will serve as a template that can be translated for sensing additional analytes (e.g., lactate, urea, pyruvate, cholesterol) and can be used for monitoring other chronic conditions.
Collapse
|
13
|
Soto RJ, Hall JR, Brown MD, Taylor JB, Schoenfisch MH. In Vivo Chemical Sensors: Role of Biocompatibility on Performance and Utility. Anal Chem 2017; 89:276-299. [PMID: 28105839 PMCID: PMC6773264 DOI: 10.1021/acs.analchem.6b04251] [Citation(s) in RCA: 51] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Robert J. Soto
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - Jackson R. Hall
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - Micah D. Brown
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - James B. Taylor
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| | - Mark H. Schoenfisch
- Department of Chemistry, University of North Carolina at Chapel Hill, CB 3290, Chapel Hill, NC 27599
| |
Collapse
|
14
|
Hu Y, Liang B, Fang L, Ma G, Yang G, Zhu Q, Chen S, Ye X. Antifouling Zwitterionic Coating via Electrochemically Mediated Atom Transfer Radical Polymerization on Enzyme-Based Glucose Sensors for Long-Time Stability in 37 °C Serum. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2016; 32:11763-11770. [PMID: 27756132 DOI: 10.1021/acs.langmuir.6b03016] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
In this study, a versatile fabrication method for coating enzyme-based biosensors with ultrathin antifouling zwitterionic polymer films to meet the challenge of the long-time stability of sensors in vivo was developed. Electrochemically mediated atom transfer radical polymerization (eATRP) was applied to polymerize zwitterionic sulfobetaine methacrylate monomers on the rough enzyme-absorbed electrode surfaces; meanwhile, a refined overall bromination was developed to improve the coverage of polymers on the biosensor surfaces and to maintain the enzyme activity simultaneously for the first time. X-ray photoelectron spectroscopy and atomic force microscopy were used to characterize the properties of the polymer layers. The antifouling performance and long-time stability in 37 °C undiluted bovine serum in vitro were evaluated. The results showed that the polymer brush coatings diminished over 99% nonspecific protein adsorption and that the sensitivity of the evaluated sensor was maintained at 94% after 15 days. The overall sensitivity deviation of 7% was nearly 50% lower than that of the polyurethane-coated ones and also much smaller than the current commercially available glucose biosensors. The results suggested that this highly controllable electrodeposition procedure could be a promising method to develop implantable biosensors with long-time stability.
Collapse
Affiliation(s)
- Yichuan Hu
- Zhijiang College, Zhejiang University of Technology , Hangzhou 310027, P. R. China
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Lucisano JY, Routh TL, Lin JT, Gough DA. Glucose Monitoring in Individuals With Diabetes Using a Long-Term Implanted Sensor/Telemetry System and Model. IEEE Trans Biomed Eng 2016; 64:1982-1993. [PMID: 27775510 DOI: 10.1109/tbme.2016.2619333] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE The use of a fully implanted first-generation prototype sensor/telemetry system is described for long-term monitoring of subcutaneous tissue glucose in a small cohort of people with diabetes. METHODS Sensors are based on a membrane containing immobilized glucose oxidase and catalase coupled to oxygen electrodes and a telemetry system, integrated as an implant. The devices remained implanted for up to 180 days, with signals transmitted every 2 min to external receivers. RESULTS The data include signal recordings from glucose clamps and spontaneous glucose excursions, matched, respectively, to reference blood glucose and finger-stick values. The sensor signals indicate dynamic tissue glucose, for which there is no independent standard, and a model describing the relationship between blood glucose and the signal is, therefore, included. The values of all model parameters have been estimated, including the permeability of adjacent tissues to glucose, and equated to conventional mass transfer parameters. As a group, the sensor calibration varied randomly at an average rate of -2.6%/week. Statistical correlation indicated strong association between the sensor signals and reference glucose values. CONCLUSION Continuous long-term glucose monitoring in individuals with diabetes is feasible with this system. SIGNIFICANCE All therapies for diabetes are based on glucose control, and therefore, require glucose monitoring. This fully implanted long-term sensor/telemetry system may facilitate a new era of management of the disease.
Collapse
|
16
|
Gillooly JF, Gomez JP, Mavrodiev EV, Rong Y, McLamore ES. Body mass scaling of passive oxygen diffusion in endotherms and ectotherms. Proc Natl Acad Sci U S A 2016; 113:5340-5. [PMID: 27118837 PMCID: PMC4868413 DOI: 10.1073/pnas.1519617113] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The area and thickness of respiratory surfaces, and the constraints they impose on passive oxygen diffusion, have been linked to differences in oxygen consumption rates and/or aerobic activity levels in vertebrates. However, it remains unclear how respiratory surfaces and associated diffusion rates vary with body mass across vertebrates, particularly in relation to the body mass scaling of oxygen consumption rates. Here we address these issues by first quantifying the body mass dependence of respiratory surface area and respiratory barrier thickness for a diversity of endotherms (birds and mammals) and ectotherms (fishes, amphibians, and reptiles). Based on these findings, we then use Fick's law to predict the body mass scaling of oxygen diffusion for each group. Finally, we compare the predicted body mass dependence of oxygen diffusion to that of oxygen consumption in endotherms and ectotherms. We find that the slopes and intercepts of the relationships describing the body mass dependence of passive oxygen diffusion in these two groups are statistically indistinguishable from those describing the body mass dependence of oxygen consumption. Thus, the area and thickness of respiratory surfaces combine to match oxygen diffusion capacity to oxygen consumption rates in both air- and water-breathing vertebrates. In particular, the substantially lower oxygen consumption rates of ectotherms of a given body mass relative to those of endotherms correspond to differences in oxygen diffusion capacity. These results provide insights into the long-standing effort to understand the structural attributes of organisms that underlie the body mass scaling of oxygen consumption.
Collapse
Affiliation(s)
- James F Gillooly
- Department of Biology, University of Florida, Gainesville, FL 32611;
| | - Juan Pablo Gomez
- Department of Biology, University of Florida, Gainesville, FL 32611; Florida Museum of Natural History, University of Florida, Gainesville, FL 32611
| | - Evgeny V Mavrodiev
- Florida Museum of Natural History, University of Florida, Gainesville, FL 32611
| | - Yue Rong
- Department of Agricultural and Biological Engineering, University of Florida, Gainesville, FL 32611
| | - Eric S McLamore
- Department of Agricultural and Biological Engineering, University of Florida, Gainesville, FL 32611
| |
Collapse
|
17
|
Aggidis AG, Newman JD, Aggidis GA. Investigating pipeline and state of the art blood glucose biosensors to formulate next steps. Biosens Bioelectron 2015; 74:243-62. [DOI: 10.1016/j.bios.2015.05.071] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2015] [Revised: 05/28/2015] [Accepted: 05/31/2015] [Indexed: 11/29/2022]
|
18
|
Abstract
For implantable sensors to become a more viable option for continuous glucose monitoring strategies, they must be able to persist in vivo for periods longer than the 3- to 7-day window that is the current industry standard. Recent studies have attributed such limited performance to tissue reactions resulting from implantation. While in vivo biocompatibility studies have provided much in the way of understanding histology surrounding an implanted sensor, little is known about how each constituent of the foreign body response affects sensor function. Due to the ordered composition and geometry of implant-associated tissue reactions, their effects on sensor function may be computationally modeled and analyzed in a way that would be prohibitive using in vivo studies. This review both explains how physiologically accurate computational models of implant-associated tissue reaction can be designed and shows how they have been utilized thus far. Going forward, these in silico models of implanted sensor behavior may soon complement in vivo studies to provide valuable information for improved sensor designs.
Collapse
Affiliation(s)
- Matthew T Novak
- Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | | |
Collapse
|
19
|
Novak MT, Yuan F, Reichert WM. Macrophage embedded fibrin gels: an in vitro platform for assessing inflammation effects on implantable glucose sensors. Biomaterials 2014; 35:9563-72. [PMID: 25175597 DOI: 10.1016/j.biomaterials.2014.08.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Accepted: 08/01/2014] [Indexed: 11/28/2022]
Abstract
The erroneous and unpredictable behavior of percutaneous glucose sensors just days following implantation has limited their clinical utility for diabetes management. Recent research has implicated the presence of adherent inflammatory cells as the key mitigating factor limiting sensor functionality in this period of days post-implantation. Here we present a novel in vitro platform to mimic the cell-embedded provisional matrix that forms adjacent to the sensor immediately after implantation for the focused investigation of the effects of early stage tissue response on sensor function. This biomimetic surrogate is formed by imbibing fibrin-based gels with physiological densities of inflammatory RAW 264.7 macrophages. When surrounding functional sensors, macrophage-embedded fibrin gels contribute to sensor signal declines that are similar in both shape and magnitude to those observed in previous whole blood and small animal studies. Signal decline in the presence of gels is both metabolically-mediated and sensitive to cell type and activation. Computational modeling of the experimental setup is also presented to validate the design by showing that the cellular glucose uptake parameters necessary to achieve such experimental declines align well with literature values. Together, these data suggest this in vitro provisional matrix surrogate may serve as an effective screening tool for testing the biocompatibility of future glucose sensor designs.
Collapse
Affiliation(s)
- Matthew T Novak
- Department of Biomedical Engineering, Duke University, 136 Hudson Hall, Box 90281, Durham, NC 27708, USA
| | - Fan Yuan
- Department of Biomedical Engineering, Duke University, 136 Hudson Hall, Box 90281, Durham, NC 27708, USA
| | - William M Reichert
- Department of Biomedical Engineering, Duke University, 136 Hudson Hall, Box 90281, Durham, NC 27708, USA.
| |
Collapse
|